SNMP-TMUX-MIB

File: SNMP-TMUX-MIB.mib (12111 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB

Imported symbols

enterprises Gauge Counter
OBJECT-TYPE TRAP-TYPE DisplayString

Defined Values

tandem 1.3.6.1.4.1.169
OBJECT IDENTIFIER    

nonstopsystems 1.3.6.1.4.1.169.3
OBJECT IDENTIFIER    

ztmx 1.3.6.1.4.1.169.3.185
OBJECT IDENTIFIER    

ztmxPDUStatistics 1.3.6.1.4.1.169.3.185.1
OBJECT IDENTIFIER    

ztmxProcess 1.3.6.1.4.1.169.3.185.2
OBJECT IDENTIFIER    

ztmxSpecial 1.3.6.1.4.1.169.3.185.3
OBJECT IDENTIFIER    

ztmxUdpStatsCurrTime 1.3.6.1.4.1.169.3.185.1.1
String showing the current time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxUdpInDatagrams 1.3.6.1.4.1.169.3.185.1.2
The total number of UPD datagrams delivered to the TMUX process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInDecodeErrors 1.3.6.1.4.1.169.3.185.1.3
The total number of UPD datagrams delivered to the TMUX process that could not be interpreted as SNMP V.1 PDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInGetPdus 1.3.6.1.4.1.169.3.185.1.4
The total number of Get PDUs received by the TMUX process. These are probably strayed PDUs as the TMUX process is bound to the TRAP port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInGetNextPdus 1.3.6.1.4.1.169.3.185.1.5
The total number of GetNext PDUs received by the TMUX process. These are probably strayed PDUs as the TMUX process is bound to the TRAP port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInSetPdus 1.3.6.1.4.1.169.3.185.1.6
The total number of Set PDUs received by the TMUX process. These are probably strayed PDUs as the TMUX process is bound to the TRAP port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInGetResponsePdus 1.3.6.1.4.1.169.3.185.1.7
The total number of GetResponse PDUs received by the TMUX process. These are probably strayed PDUs as the TMUX process is bound to the TRAP port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInTrapPdus 1.3.6.1.4.1.169.3.185.1.8
The total number of Trap PDUs received by the TMUX process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxTrapStatistics 1.3.6.1.4.1.169.3.185.1.9
OBJECT IDENTIFIER    

ztmxTrapStatsCurrTime 1.3.6.1.4.1.169.3.185.1.9.1
String showing the current time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxInColdStartTraps 1.3.6.1.4.1.169.3.185.1.9.2
The total number of Trap PDUs received by the TMUX process that report reinitiation but the configuration of the sender may change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInWarmStartTraps 1.3.6.1.4.1.169.3.185.1.9.3
The total number of Trap PDUs received by the TMUX process that report reinitiation but the configuration of the sender will not change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInLinkDownTraps 1.3.6.1.4.1.169.3.185.1.9.4
The total number of Trap PDUs received by the TMUX process that report a failure in one of the agent's links.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInLinkUpTraps 1.3.6.1.4.1.169.3.185.1.9.5
The total number of Trap PDUs received by the TMUX process that report one of the links has come up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInAuthFailTraps 1.3.6.1.4.1.169.3.185.1.9.6
The total number of Trap PDUs received by the TMUX process that report improper authentication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInEgpNeighborLossTraps 1.3.6.1.4.1.169.3.185.1.9.7
The total number of Trap PDUs received by the TMUX process that report an exterior gateway protocol neighbor is lost.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxInEnterpriseSpecificTraps 1.3.6.1.4.1.169.3.185.1.9.8
The total number of Trap PDUs received by the TMUX process that report an enterprise specific event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxProcCurrTime 1.3.6.1.4.1.169.3.185.2.1
String showing the current time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcVersion 1.3.6.1.4.1.169.3.185.2.2
String showing the version of the subagent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcName 1.3.6.1.4.1.169.3.185.2.3
String showing the process name.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcPaid 1.3.6.1.4.1.169.3.185.2.4
String showing the process access id ('group.user').
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcPrimPID 1.3.6.1.4.1.169.3.185.2.5
String showing the primary process PID ('CPU,PIN').
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcBkupPID 1.3.6.1.4.1.169.3.185.2.6
String showing the backup process PID ('CPU,PIN').
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcCreatTime 1.3.6.1.4.1.169.3.185.2.7
String showing the process creation time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcCpuTime 1.3.6.1.4.1.169.3.185.2.8
Process CPU time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcPri 1.3.6.1.4.1.169.3.185.2.9
Intitial process priority. Valid range 1-199
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ztmxProcHomeTerm 1.3.6.1.4.1.169.3.185.2.10
String showing the process home terminal name.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcHeapInitial 1.3.6.1.4.1.169.3.185.2.11
Intial heap size (in Bytes).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ztmxProcHeapCurrent 1.3.6.1.4.1.169.3.185.2.12
Current heap size (in Bytes).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ztmxProcEmsCollector 1.3.6.1.4.1.169.3.185.2.13
String showing the name of the EMS collector process the TMUX process is writing the translated EMS events to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcAgent 1.3.6.1.4.1.169.3.185.2.14
String showing the name of the agent process the TMUX process is interfacing with.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcAgentSessionStatus 1.3.6.1.4.1.169.3.185.2.15
The status of the session between the TMUX process and the agent. If state is not 'open' the TMUX process was not able to establish communication with the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER open(1), close(2)  

ztmxProcUdpPort 1.3.6.1.4.1.169.3.185.2.16
UDP Port number the TMUX process binds to to receive TRAP PDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ztmxProcTcpIpProcess 1.3.6.1.4.1.169.3.185.2.17
String showing the name(s) of the TCP/IP process the TMUX process is receiving TRAP PDUs from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxSwitchToBackupNow 1.3.6.1.4.1.169.3.185.2.18
If set to forceBackupTakeover, the backup process will take over and a new backup is created.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER autoProcessPairControl(0), forceBackupTakeover(1)  

ztmxProcProgramFileName 1.3.6.1.4.1.169.3.185.2.19
String showing the proram file name of the TMUX process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztmxProcEmsWriteTotal 1.3.6.1.4.1.169.3.185.2.20
Total count of write operations to the EMS collector process. Each write operation attempts to send a trap event to the EMS collector.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ztmxProcEmsWriteErrors 1.3.6.1.4.1.169.3.185.2.21
Count of write operations to the EMS collector process that did not complete normally. It's likely that the trap event that was sent with such operation was not successfully stored in the EMS database.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter