SNI-BUS-MIB
File:
SNI-BUS-MIB.mib (40363 bytes)
Imported modules
Imported symbols
Defined Types
SniFunctionEntry |
|
SEQUENCE |
|
|
|
|
sniBusType |
INTEGER |
|
|
sniBusIndex |
INTEGER |
|
|
sniDeviceSlotNo |
INTEGER |
|
|
sniFunctionNo |
INTEGER |
|
|
sniDeviceType |
INTEGER |
|
|
sniDeviceTypeName |
DisplayString |
|
|
sniDeviceName |
DisplayString |
|
|
sniVendorName |
DisplayString |
|
|
sniPhysicalSlotNo |
INTEGER |
|
|
sniAdapterSpecificData |
OCTET STRING |
|
|
sniOsDeviceName |
DisplayString |
|
|
sniPhysicalSlotDesignation |
DisplayString |
|
|
sniCompLocationKey |
OCTET STRING |
|
SniEisaFunctionEntry |
|
SEQUENCE |
|
|
|
|
sniEisaBusIndex |
INTEGER |
|
|
sniEisaSlotNo |
INTEGER |
|
|
sniEisaFunctionNo |
INTEGER |
|
|
sniEisaSlotType |
INTEGER |
|
|
sniEisaConfigurationComplete |
INTEGER |
|
|
sniEisaType |
DisplayString |
|
|
sniEisaValid |
INTEGER |
|
|
sniEisaId |
DisplayString |
|
|
sniEisaName |
DisplayString |
|
|
sniEisaAgentType |
INTEGER |
|
SniPciFunctionEntry |
|
SEQUENCE |
|
|
|
|
sniPciBusIndex |
INTEGER |
|
|
sniPciDeviceNo |
INTEGER |
|
|
sniPciFunctionNo |
INTEGER |
|
|
sniPciVendorId |
INTEGER |
|
|
sniPciDeviceId |
INTEGER |
|
|
sniPciRevisionId |
INTEGER |
|
|
sniPciBaseClass |
INTEGER |
|
|
sniPciSubClass |
INTEGER |
|
|
sniPciProgIf |
INTEGER |
|
|
sniPciBuiltInSelfTest |
INTEGER |
|
|
sniPciInterruptPin |
INTEGER |
|
|
sniPciInterruptLine |
INTEGER |
|
|
sniPciSpecificData |
OCTET STRING |
|
|
sniPciSecondaryBusIndex |
INTEGER |
|
|
sniPciSecondaryBusType |
INTEGER |
|
|
sniPciSubDeviceId |
INTEGER |
|
|
sniPciSubVendorId |
INTEGER |
|
|
sniPciVendorName |
DisplayString |
|
|
sniPciSubVendorName |
DisplayString |
|
SniMemoryEntry |
|
SEQUENCE |
|
|
|
|
sniMemBusType |
INTEGER |
|
|
sniMemBusIndex |
INTEGER |
|
|
sniMemSlotDevice |
INTEGER |
|
|
sniMemFunctionNo |
INTEGER |
|
|
sniMemoryNo |
INTEGER |
|
|
sniBusSharedMemory |
INTEGER |
|
|
sniBusMemoryStart |
INTEGER |
|
|
sniBusMemoryLength |
INTEGER |
|
|
sniBusMemoryStartHigh |
INTEGER |
|
SniInterruptEntry |
|
SEQUENCE |
|
|
|
|
sniIntBusType |
INTEGER |
|
|
sniIntBusIndex |
INTEGER |
|
|
sniIntSlotDevice |
INTEGER |
|
|
sniIntFunctionNo |
INTEGER |
|
|
sniInterruptNo |
INTEGER |
|
|
sniBusInterruptUsed |
INTEGER |
|
|
sniBusInterruptLevel |
INTEGER |
|
|
sniBusInterruptShared |
INTEGER |
|
|
sniBusInterruptNo |
INTEGER |
|
SniDMAEntry |
|
SEQUENCE |
|
|
|
|
sniDMABusType |
INTEGER |
|
|
sniDMABusIndex |
INTEGER |
|
|
sniDMASlotDevice |
INTEGER |
|
|
sniDMAFunctionNo |
INTEGER |
|
|
sniDMANo |
INTEGER |
|
|
sniBusDMAChannel |
INTEGER |
|
|
sniBusDMATiming |
INTEGER |
|
|
sniBusDMATransferSize |
INTEGER |
|
SniPortEntry |
|
SEQUENCE |
|
|
|
|
sniPortBusType |
INTEGER |
|
|
sniPortBusIndex |
INTEGER |
|
|
sniPortSlotDevice |
INTEGER |
|
|
sniPortFunctionNo |
INTEGER |
|
|
sniPortNo |
INTEGER |
|
|
sniBusIOFirstPort |
INTEGER |
|
|
sniBusIONoOfPorts |
INTEGER |
|
|
sniBusIOPortShared |
INTEGER |
|
SvPciFunctionEntry |
|
SEQUENCE |
|
|
|
|
svPciSegmentNo |
INTEGER |
|
|
svPciBusIndex |
INTEGER |
|
|
svPciDeviceNo |
INTEGER |
|
|
svPciFunctionNo |
INTEGER |
|
|
svPciVendorId |
INTEGER |
|
|
svPciDeviceId |
INTEGER |
|
|
svPciRevisionId |
INTEGER |
|
|
svPciBaseClass |
INTEGER |
|
|
svPciSubClass |
INTEGER |
|
|
svPciProgIf |
INTEGER |
|
|
svPciBuiltInSelfTest |
INTEGER |
|
|
svPciInterruptPin |
INTEGER |
|
|
svPciInterruptLine |
INTEGER |
|
|
svPciSpecificData |
OCTET STRING |
|
|
svPciSecondaryBusIndex |
INTEGER |
|
|
svPciSecondaryBusType |
INTEGER |
|
|
svPciSubDeviceId |
INTEGER |
|
|
svPciSubVendorId |
INTEGER |
|
|
svPciVendorName |
DisplayString |
|
|
svPciSubVendorName |
DisplayString |
|
|
svPciDeviceName |
DisplayString |
|
|
svPciAdapterUniqueId |
OCTET STRING |
|
|
svPciAdapterSpecificData |
OCTET STRING |
|
|
svPciPhysicalSlotDesignation |
DisplayString |
|
|
svPciCompLocationKey |
OCTET STRING |
|
Defined Values
sni |
1.3.6.1.4.1.231 |
OBJECT IDENTIFIER |
|
|
|
sniCommon |
1.3.6.1.4.1.231.2.10.2.2 |
OBJECT IDENTIFIER |
|
|
|
sniBios |
1.3.6.1.4.1.231.2.10.2.2.1 |
OBJECT IDENTIFIER |
|
|
|
sniEisa |
1.3.6.1.4.1.231.2.10.2.2.2 |
OBJECT IDENTIFIER |
|
|
|
sniHd |
1.3.6.1.4.1.231.2.10.2.2.3 |
OBJECT IDENTIFIER |
|
|
|
sniBus |
1.3.6.1.4.1.231.2.10.2.2.4 |
OBJECT IDENTIFIER |
|
|
|
sniScb |
1.3.6.1.4.1.231.2.10.2.4 |
OBJECT IDENTIFIER |
|
|
|
sniNetware |
1.3.6.1.4.1.231.2.10.2.5.1 |
OBJECT IDENTIFIER |
|
|
|
sniWinNt |
1.3.6.1.4.1.231.2.10.2.5.2 |
OBJECT IDENTIFIER |
|
|
|
sniOs2 |
1.3.6.1.4.1.231.2.10.2.5.3 |
OBJECT IDENTIFIER |
|
|
|
sniUnix |
1.3.6.1.4.1.231.2.10.2.5.4 |
OBJECT IDENTIFIER |
|
|
|
sniOemDpt |
1.3.6.1.4.1.231.2.10.2.6.1 |
OBJECT IDENTIFIER |
|
|
|
sniOemMylex |
1.3.6.1.4.1.231.2.10.2.6.2 |
OBJECT IDENTIFIER |
|
|
|
sniTrapMib |
1.3.6.1.4.1.231.2.10.5 |
OBJECT IDENTIFIER |
|
|
|
sniBusEisa |
1.3.6.1.4.1.231.2.10.2.2.4.2 |
OBJECT IDENTIFIER |
|
|
|
sniBusPci |
1.3.6.1.4.1.231.2.10.2.2.4.3 |
OBJECT IDENTIFIER |
|
|
|
svBusPciEx |
1.3.6.1.4.1.231.2.10.2.2.4.6 |
OBJECT IDENTIFIER |
|
|
|
sniEisaSlots |
1.3.6.1.4.1.231.2.10.2.2.4.1.1 |
Number of eisa slots in the system. 0 if no EISA-Bus present. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniIsaSlots |
1.3.6.1.4.1.231.2.10.2.2.4.1.2 |
Number of isa slots in the system. 0 if no ISA-Bus present. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciSlots |
1.3.6.1.4.1.231.2.10.2.2.4.1.3 |
Number of pci slots in the system. 0 if no PCI-Bus present. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniFunctionTable |
1.3.6.1.4.1.231.2.10.2.2.4.1.4 |
Table of all common data for all functions |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SniFunctionEntry |
|
sniFunctionEntry |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1 |
|
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SniFunctionEntry |
|
|
sniBusType |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.1 |
Type of the bus |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), isa(2), eisa(3), pci(5), usb(6), firewire(7), ata(8) |
|
sniBusIndex |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.2 |
Index of the bus based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniDeviceSlotNo |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.3 |
Device- or Slot-number based on 0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniFunctionNo |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.4 |
Functionnumber based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniDeviceType |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.5 |
indicates the type of device |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), diskcontroller(1), tapecontroller(2), cdromcontoller(3), wormcontroller(4), serialcontroller(5), networkcontroller(6), displaycontroller(7), parallelcontroller(8), pointercontoller(9), keyboardcontroller(10), audiocontroller(11), othercontroller(12), bridge-device(13), cpu(14) |
|
sniDeviceName |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.7 |
Operating system independent name of device in readable form |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sniVendorName |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.8 |
manufacturer of the device in readable form |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sniPhysicalSlotNo |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.9 |
indicates the physical slot the device resides in (0: onboard device, -1: not available) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniAdapterSpecificData |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.10 |
Specific data for this adapter. Currently the only information defined
is the MAC address for lan adapters. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
sniOsDeviceName |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.11 |
Operating system specific display name for the device |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sniCompLocationKey |
1.3.6.1.4.1.231.2.10.2.2.4.1.4.1.13 |
Device location key, used for identifying the component; e.g. 'TYPE_PCI&BUS_3&DEV_14&FUNC_0' |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sniEisaFunctionEntry |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1 |
|
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SniEisaFunctionEntry |
|
|
sniEisaBusIndex |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1.1 |
Index of the bus based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniEisaSlotNo |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1.2 |
Slot number based on 0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniEisaFunctionNo |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1.3 |
Eisa function number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniEisaSlotType |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1.4 |
Type of the slot |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
expansion-slot(1), embedded-slot(2), virtual-slot(3), reserved(4) |
|
sniEisaConfigurationComplete |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1.5 |
True if board is completely configured |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
true(1), false(2), unknown(3) |
|
sniEisaType |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1.6 |
Type and subtype as ASCII string |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sniEisaValid |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1.7 |
True, if the slot contains a correctly configured eisa board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
true(1), false(2), unknown(3) |
|
sniEisaId |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1.8 |
The eisa id of the board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sniEisaName |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1.9 |
Visual name of the board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sniEisaAgentType |
1.3.6.1.4.1.231.2.10.2.2.4.2.1.1.10 |
|
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ethernet-adapter(2), token-ring-adapter(3), fddi-adapter(4), hd-adapter(5), extended-hd-adapter(6), cpu(7) |
|
sniPciFunctionEntry |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1 |
|
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SniPciFunctionEntry |
|
|
sniPciBusIndex |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.1 |
Index of the bus based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciDeviceNo |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.2 |
Device number based on 0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciFunctionNo |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.3 |
Function number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciVendorId |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.4 |
Identifies the manufacturer of the device. This must be a value
allocated by the PCI SIG. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciDeviceId |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.5 |
Identifies the particular device. This value is assigned by the
manufacturer. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciRevisionId |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.6 |
Specifies the revision level of the device described by
sniPciDeviceId. This value is assigned by the manufacturer. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciBaseClass |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.7 |
Identifies type of the device, according to the PCI classification
scheme. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
old-type-device(0), mass-storage-controller(1), network-controller(2), display-controller(3), multimedia-device(4), memory-controller(5), bridge-device(6), simple-communication-controller(7), base-system-peripheral(8), input-device(9), docking-station(10), processor(11), serial-bus-controller(12), wireless-controller(13), io-controller(14), satellite-communication-controller(15), encryption-device(16), signal-processor(17), unknown-device(255) |
|
sniPciSubClass |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.8 |
Identifies the subtype, if any, of the device, according to the PCI
classification scheme. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciProgIf |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.9 |
Identifies the register-level programming interface, if any, for the
device, according to the PCI classification scheme. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciBuiltInSelfTest |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.10 |
Indicates if the device does support built-in self test. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
built-in(1), not-built-in(2), unknown(3) |
|
sniPciInterruptPin |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.11 |
Indicates which interrupt pin the PCI device uses. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
not-implemented(0), inta(1), intb(2), intc(3), intd(4) |
|
sniPciInterruptLine |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.12 |
Indicates the input of the system interrupt controller that the
interrupt pin is connected to. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciSpecificData |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.13 |
This is device specific data found in the COMMON CONFIGURATION SPACE.
This field is currently not used and therefor filled with zeros. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
sniPciSecondaryBusIndex |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.14 |
Valid only for a bridge device. This is the index of the bridge's
secondary bus (-1 = no bus index available; ignore this field). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciSecondaryBusType |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.15 |
Valid only for a bridge device. This is the type of the bridge's secondary bus.
Following values are defined (according to PCI Local bus specification, Revision 2.1, values
are incremented by 1):
00h: Unknown value; ignore this field
01h: Host bridge (bridge to CPU bus)
02h: ISA bridge
03h: EISA bridge
04h: MCA bridge
05h: PCI-to-PCI bridge
06h: PCMCIA bridge
07h: NuBus bridge
80h: Other bridge device |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciSubVendorId |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.16 |
Identifies the particular device. This value is assigned by the manufacturer. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPciSubDeviceId |
1.3.6.1.4.1.231.2.10.2.2.4.3.1.1.17 |
Identifies the particular device. This value is assigned by the manufacturer. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniMemoryTable |
1.3.6.1.4.1.231.2.10.2.2.4.4.1 |
Table of all memory entries |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SniMemoryEntry |
|
sniMemoryEntry |
1.3.6.1.4.1.231.2.10.2.2.4.4.1.1 |
|
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SniMemoryEntry |
|
|
sniMemBusType |
1.3.6.1.4.1.231.2.10.2.2.4.4.1.1.1 |
Type of the bus |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), isa(2), eisa(3), pci(5) |
|
sniMemBusIndex |
1.3.6.1.4.1.231.2.10.2.2.4.4.1.1.2 |
Index of the bus based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniMemSlotDevice |
1.3.6.1.4.1.231.2.10.2.2.4.4.1.1.3 |
Slot or Device number based on 0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniMemFunctionNo |
1.3.6.1.4.1.231.2.10.2.2.4.4.1.1.4 |
Function number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniMemoryNo |
1.3.6.1.4.1.231.2.10.2.2.4.4.1.1.5 |
Memory number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusSharedMemory |
1.3.6.1.4.1.231.2.10.2.2.4.4.1.1.6 |
Type of shared memory |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
not-used(1), other(2), system(3), expanded(4), virtual(5) |
|
sniBusMemoryStart |
1.3.6.1.4.1.231.2.10.2.2.4.4.1.1.7 |
Start address (low DWORD part) of shared memory or 0 if not used |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusMemoryLength |
1.3.6.1.4.1.231.2.10.2.2.4.4.1.1.8 |
Length of shared memory or 0 if not used |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusMemoryStartHigh |
1.3.6.1.4.1.231.2.10.2.2.4.4.1.1.9 |
Start address (high DWORD part) of shared memory or 0 if not used |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniInterruptEntry |
1.3.6.1.4.1.231.2.10.2.2.4.4.2.1 |
|
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SniInterruptEntry |
|
|
sniIntBusType |
1.3.6.1.4.1.231.2.10.2.2.4.4.2.1.1 |
Type of the bus |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), isa(2), eisa(3), pci(5) |
|
sniIntBusIndex |
1.3.6.1.4.1.231.2.10.2.2.4.4.2.1.2 |
Index of the bus based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniIntSlotDevice |
1.3.6.1.4.1.231.2.10.2.2.4.4.2.1.3 |
Slot or Device number based on 0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniIntFunctionNo |
1.3.6.1.4.1.231.2.10.2.2.4.4.2.1.4 |
Function number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniInterruptNo |
1.3.6.1.4.1.231.2.10.2.2.4.4.2.1.5 |
Interrupt number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusInterruptUsed |
1.3.6.1.4.1.231.2.10.2.2.4.4.2.1.6 |
True if and only if not unknown and an interrupt is used |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
true(1), false(2), unknown(3) |
|
sniBusInterruptLevel |
1.3.6.1.4.1.231.2.10.2.2.4.4.2.1.7 |
interrupt level |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), edge-triggered(2), level-triggered(3) |
|
sniBusInterruptShared |
1.3.6.1.4.1.231.2.10.2.2.4.4.2.1.8 |
True if and only if not unknown and an interrupt is shared |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
true(1), false(2), unknown(3) |
|
sniBusInterruptNo |
1.3.6.1.4.1.231.2.10.2.2.4.4.2.1.9 |
interrupt number used |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniDMATable |
1.3.6.1.4.1.231.2.10.2.2.4.4.3 |
Table of all dma entries |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SniDMAEntry |
|
sniDMAEntry |
1.3.6.1.4.1.231.2.10.2.2.4.4.3.1 |
|
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SniDMAEntry |
|
|
sniDMABusType |
1.3.6.1.4.1.231.2.10.2.2.4.4.3.1.1 |
Type of the bus |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), isa(2), eisa(3), pci(5) |
|
sniDMABusIndex |
1.3.6.1.4.1.231.2.10.2.2.4.4.3.1.2 |
Index of the bus based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniDMASlotDevice |
1.3.6.1.4.1.231.2.10.2.2.4.4.3.1.3 |
Slot or Device number based on 0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniDMAFunctionNo |
1.3.6.1.4.1.231.2.10.2.2.4.4.3.1.4 |
Function number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniDMANo |
1.3.6.1.4.1.231.2.10.2.2.4.4.3.1.5 |
DMA number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusDMAChannel |
1.3.6.1.4.1.231.2.10.2.2.4.4.3.1.6 |
DMA channel |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusDMATiming |
1.3.6.1.4.1.231.2.10.2.2.4.4.3.1.7 |
DMA timing |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), default-timing(2), type-a-timing(3), type-b-timing(4) |
|
sniBusDMATransferSize |
1.3.6.1.4.1.231.2.10.2.2.4.4.3.1.8 |
DMA transfer size |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), bit-8(2), bit-16(3), bit-32(4) |
|
sniPortTable |
1.3.6.1.4.1.231.2.10.2.2.4.4.4 |
Table of all port entries |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SniPortEntry |
|
sniPortEntry |
1.3.6.1.4.1.231.2.10.2.2.4.4.4.1 |
|
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SniPortEntry |
|
|
sniPortBusType |
1.3.6.1.4.1.231.2.10.2.2.4.4.4.1.1 |
Type of the bus |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), isa(2), eisa(3), pci(5) |
|
sniPortBusIndex |
1.3.6.1.4.1.231.2.10.2.2.4.4.4.1.2 |
Index of the bus based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPortSlotDevice |
1.3.6.1.4.1.231.2.10.2.2.4.4.4.1.3 |
Slot or Device number based on 0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPortFunctionNo |
1.3.6.1.4.1.231.2.10.2.2.4.4.4.1.4 |
Function number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniPortNo |
1.3.6.1.4.1.231.2.10.2.2.4.4.4.1.5 |
Port number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusIOFirstPort |
1.3.6.1.4.1.231.2.10.2.2.4.4.4.1.6 |
First io port used |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusIONoOfPorts |
1.3.6.1.4.1.231.2.10.2.2.4.4.4.1.7 |
Number of io ports used |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusIOPortShared |
1.3.6.1.4.1.231.2.10.2.2.4.4.4.1.8 |
True if io port is shared |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
true(1), false(2), unknown(3) |
|
sniBusCompBusType |
1.3.6.1.4.1.231.2.10.2.2.4.5.1.1.1 |
Type of the bus (ISA, EISA, PCI) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), isa(2), eisa(3), pci(5) |
|
sniBusCompBusNumber |
1.3.6.1.4.1.231.2.10.2.2.4.5.1.1.2 |
Bus number for the specified bus type (1..n) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusCompDeviceNo |
1.3.6.1.4.1.231.2.10.2.2.4.5.1.1.3 |
Device number (PCI) or slot number (ISA, EISA) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusCompSlotNo |
1.3.6.1.4.1.231.2.10.2.2.4.5.1.1.4 |
Physical slot number (0..n), -1 if unknown |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sniBusCompEisaPciId |
1.3.6.1.4.1.231.2.10.2.2.4.5.1.1.7 |
EISA ID for EISA components, PCI vendor/device ID for PCI components (hexadecimal notation) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
svPciFunctionEntry |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1 |
|
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SvPciFunctionEntry |
|
|
svPciSegmentNo |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.1 |
PCI segment number (zero based) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciBusIndex |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.2 |
Index of the bus based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciDeviceNo |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.3 |
Device number based on 0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciFunctionNo |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.4 |
Function number based on 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciVendorId |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.5 |
Identifies the manufacturer of the device. This must be a value
allocated by the PCI SIG. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciSubVendorId |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.6 |
Identifies the particular device. This value is assigned by the manufacturer. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciDeviceId |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.7 |
Identifies the particular device. This value is assigned by the
manufacturer. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciSubDeviceId |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.8 |
Identifies the particular device. This value is assigned by the manufacturer. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciRevisionId |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.9 |
Specifies the revision level of the device described by
svPciDeviceId. This value is assigned by the manufacturer. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciBaseClass |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.10 |
Identifies type of the device, according to the PCI classification
scheme. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
old-type-device(0), mass-storage-controller(1), network-controller(2), display-controller(3), multimedia-device(4), memory-controller(5), bridge-device(6), simple-communication-controller(7), base-system-peripheral(8), input-device(9), docking-station(10), processor(11), serial-bus-controller(12), wireless-controller(13), io-controller(14), satellite-communication-controller(15), encryption-device(16), signal-processor(17), unknown-device(255) |
|
svPciSubClass |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.11 |
Identifies the subtype, if any, of the device, according to the PCI
classification scheme. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciProgIf |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.12 |
Identifies the register-level programming interface, if any, for the
device, according to the PCI classification scheme. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciBuiltInSelfTest |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.13 |
Indicates if the device does support built-in self test. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
built-in(1), not-built-in(2), unknown(3) |
|
svPciInterruptPin |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.14 |
Indicates which interrupt pin the PCI device uses. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
not-implemented(0), inta(1), intb(2), intc(3), intd(4) |
|
svPciInterruptLine |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.15 |
Indicates the input of the system interrupt controller that the
interrupt pin is connected to. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciSpecificData |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.16 |
This is device specific data found in the COMMON CONFIGURATION SPACE.
This field is currently not used and therefor filled with zeros. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
svPciSecondaryBusIndex |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.17 |
Valid only for a bridge device. This is the index of the bridge's
secondary bus (-1 = no bus index available; ignore this field). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciSecondaryBusType |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.18 |
Valid only for a bridge device. This is the type of the bridge's secondary bus.
Following values are defined (according to PCI Local bus specification, Revision 2.1, values
are incremented by 1):
00h: Unknown value; ignore this field
01h: Host bridge (bridge to CPU bus)
02h: ISA bridge
03h: EISA bridge
04h: MCA bridge
05h: PCI-to-PCI bridge
06h: PCMCIA bridge
07h: NuBus bridge
80h: Other bridge device |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
svPciDeviceName |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.21 |
Operating system independent name of device in readable form |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
svPciAdapterUniqueId |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.22 |
Unigue adapter type specific ID. MAC address for lan adapters. WWN for fibre channel adapters. Otherwise empty. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
svPciAdapterSpecificData |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.23 |
Specific data for this adapter. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
svPciCompLocationKey |
1.3.6.1.4.1.231.2.10.2.2.4.6.1.1.25 |
Unique device location key, used for identifying the component; e.g. 'TYPE_PCI&BUS_3&DEV_14&FUNC_0' or 'TYPE_PCI&BUS_3&DEV_14&FUNC_0&SEG_1' |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|