SLE-MPLS-TP-BFD-MIB

File: SLE-MPLS-TP-BFD-MIB.mib (11653 bytes)

Imported modules

DASAN-SMI IANA-BFD-TC-STD-MIB SLE-TC-MIB
SNMPv2-SMI

Imported symbols

sleMgmt IANAbfdDiagTC SleControlStatusType
SleControlRequestResultType mib-2 TimeTicks
Unsigned32 Gauge32 OBJECT-TYPE
MODULE-IDENTITY OBJECT-IDENTITY

Defined Types

SleBfdCfgInfoEntry  
SEQUENCE    
  sleMplsTpBfdCfgInfoMegIndex Unsigned32
  sleMplsTpBfdCfgInfoMeIndex Unsigned32
  sleMplsTpBfdCfgInfoMegName OCTET STRING
  sleMplsTpBfdCfgInfoMeName OCTET STRING
  sleMplsTpBfdCfgInfoTxInterval OCTET STRING
  sleMplsTpBfdCfgInfoRXInterval OCTET STRING

SleBfdSessionInfoEntry  
SEQUENCE    
  sleMplsTpBfdSessionInfoSessIndex Unsigned32
  sleMplsTpBfdSessionInfoMegName OCTET STRING
  sleMplsTpBfdSessionInfoMeName OCTET STRING
  sleMplsTpBfdSessionInfoVersionNumber Unsigned32
  sleMplsTpBfdSessionInfoDiscriminator Unsigned32
  sleMplsTpBfdSessionInfoRemoteDiscriminator Unsigned32
  sleMplsTpBfdSessionInfoState INTEGER
  sleMplsTpBfdSessionInfoDiag IANAbfdDiagTC
  sleMplsTpBfdSessionInfoDesiredMinTxInterval OCTET STRING
  sleMplsTpBfdSessionInfoReqMinRxInterval OCTET STRING
  sleMplsTpBfdSessionInfoDetectMult Unsigned32

Defined Values

sleMplsTpBfd 1.3.6.1.4.1.6296.101.16.19
Bidirectional Forwarding Management Information Base.
MODULE-IDENTITY    

sleMpls 1.3.6.1.4.1.6296.101.16
SLE MPLS.
Status: current Access: read-only
OBJECT-IDENTITY    

sleMplsTpBfdCfg 1.3.6.1.4.1.6296.101.16.19.1
OBJECT IDENTIFIER    

sleMplsTpBfdCfgInfoTable 1.3.6.1.4.1.6296.101.16.19.1.1
The BFD Cfg Table describes the configuration details.
Status: current Access: read-only
OBJECT-TYPE    
  SEQUENCE OF  
    SleBfdCfgInfoEntry

sleMplsTpBfdCfgInfoEntry 1.3.6.1.4.1.6296.101.16.19.1.1.1
The BFD Session Entry describes BFD session.
Status: current Access: read-only
OBJECT-TYPE    
  SleBfdCfgInfoEntry  

sleMplsTpBfdCfgInfoMegIndex 1.3.6.1.4.1.6296.101.16.19.1.1.1.1
MEG Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..65535  

sleMplsTpBfdCfgInfoMeIndex 1.3.6.1.4.1.6296.101.16.19.1.1.1.2
Maintenance Entity Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..65535  

sleMplsTpBfdCfgInfoMegName 1.3.6.1.4.1.6296.101.16.19.1.1.1.3
MEG Index.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdCfgInfoMeName 1.3.6.1.4.1.6296.101.16.19.1.1.1.4
Maintenance Entity Index.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdCfgInfoTxInterval 1.3.6.1.4.1.6296.101.16.19.1.1.1.5
TX Packet Interval of BFD to neighbor.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdCfgInfoRXInterval 1.3.6.1.4.1.6296.101.16.19.1.1.1.6
RX Packet Interval of BFD from neighbor.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdCfgControl 1.3.6.1.4.1.6296.101.16.19.1.2
OBJECT IDENTIFIER    

sleMplsTpBfdCfgControlRequest 1.3.6.1.4.1.6296.101.16.19.1.2.1
This object holds the possible read-write columns that can be modified in the BFD Config table. For each read-write column of BFD config table, a Set Operation control value is added in this object.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER createBfdcfgEntry(1), deleteBfdCfgEntry(2), setIntervals(3)  

sleMplsTpBfdCfgControlStatus 1.3.6.1.4.1.6296.101.16.19.1.2.2
This object displays the status of the configuration done.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleMplsTpBfdCfgControlTimer 1.3.6.1.4.1.6296.101.16.19.1.2.3
This object is based on the SLE style where a timer is configured for every control table.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleMplsTpBfdCfgControlTimestamp 1.3.6.1.4.1.6296.101.16.19.1.2.4
This object specifies the time at which the configuration is done.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleMplsTpBfdCfgControlReqResult 1.3.6.1.4.1.6296.101.16.19.1.2.5
The standard result of the SET operation is stored here.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleMplsTpBfdCfgControlMegName 1.3.6.1.4.1.6296.101.16.19.1.2.6
MEG Name.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdCfgControlMeName 1.3.6.1.4.1.6296.101.16.19.1.2.7
Maintenance Entity Name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdCfgControlTxInterval 1.3.6.1.4.1.6296.101.16.19.1.2.8
TX Packet Interval of BFD to neighbor.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdCfgControlRXInterval 1.3.6.1.4.1.6296.101.16.19.1.2.9
RX Packet Interval of BFD from neighbor.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdSession 1.3.6.1.4.1.6296.101.16.19.2
OBJECT IDENTIFIER    

sleMplsTpBfdSessionInfoTable 1.3.6.1.4.1.6296.101.16.19.2.1
The BFD Session Table describes the BFD sessions.
Status: current Access: read-only
OBJECT-TYPE    
  SEQUENCE OF  
    SleBfdSessionInfoEntry

sleMplsTpBfdSessionInfoEntry 1.3.6.1.4.1.6296.101.16.19.2.1.1
The BFD Session Entry describes BFD session.
Status: current Access: read-only
OBJECT-TYPE    
  SleBfdSessionInfoEntry  

sleMplsTpBfdSessionInfoSessIndex 1.3.6.1.4.1.6296.101.16.19.2.1.1.1
This object contains an index used to represent a unique BFD session on this device.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..65535  

sleMplsTpBfdSessionInfoMegName 1.3.6.1.4.1.6296.101.16.19.2.1.1.2
MEG Name of the BFD Session.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdSessionInfoMeName 1.3.6.1.4.1.6296.101.16.19.2.1.1.3
MEG Name of the BFD Session.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdSessionInfoVersionNumber 1.3.6.1.4.1.6296.101.16.19.2.1.1.4
The version number of the BFD protocol that this session is running in. Write access is available for this object to provide ability to set desired version for this BFD session.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..7  

sleMplsTpBfdSessionInfoDiscriminator 1.3.6.1.4.1.6296.101.16.19.2.1.1.5
This object specifies the local discriminator for this BFD session, used to uniquely identify it.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..4294967295  

sleMplsTpBfdSessionInfoRemoteDiscriminator 1.3.6.1.4.1.6296.101.16.19.2.1.1.6
This object specifies the session discriminator chosen by the remote system for this BFD session. The value may be zero(0) if the remote discriminator is not yet known or if the session is in the down or adminDown(1) state.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0 | 1..4294967295  

sleMplsTpBfdSessionInfoState 1.3.6.1.4.1.6296.101.16.19.2.1.1.7
BFD session state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER adminDown(0), stateDown(1), stateInit(2), stateUp(3), unknown(4)  

sleMplsTpBfdSessionInfoDiag 1.3.6.1.4.1.6296.101.16.19.2.1.1.8
A diagnostic code specifying the local system's reason for the last transition of the session from up(4) to some other state.
Status: current Access: read-only
OBJECT-TYPE    
  IANAbfdDiagTC  

sleMplsTpBfdSessionInfoDesiredMinTxInterval 1.3.6.1.4.1.6296.101.16.19.2.1.1.9
This object specifies the minimum interval, in microseconds, that the local system would like to use when transmitting BFD Control packets. The value of zero(0) is reserved, and should not be used.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdSessionInfoReqMinRxInterval 1.3.6.1.4.1.6296.101.16.19.2.1.1.10
This object specifies the minimum interval, in microseconds, between received BFD Control packets the local system is capable of supporting. The value of zero(0) can be specified when the transmitting system does not want the remote system to send any periodic BFD control packets.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpBfdSessionInfoDetectMult 1.3.6.1.4.1.6296.101.16.19.2.1.1.11
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32