SIAE-SYNC-MIB

File: SIAE-SYNC-MIB.mib (36060 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IF-MIB
SIAE-TREE-MIB SIAE-ALARM-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Counter32 DisplayString RowStatus
ifIndex InterfaceIndexOrZero siaeMib
AlarmStatus AlarmSeverityCode

Defined Types

TimingGenerator  
SEQUENCE    
  timingGeneratorId Integer32
  timingGeneratorT4vsT0 INTEGER
  timingGeneratorHoldOffTime INTEGER
  timingGeneratorWtrTime INTEGER
  timingGeneratorSinkLosSet INTEGER
  timingGeneratorSinkLosReset INTEGER
  timingGeneratorT0SquelchAlarm AlarmStatus
  timingGeneratorT4SquelchAlarm AlarmStatus
  timingGeneratorFreeRunningStatus AlarmStatus
  timingGeneratorHoldoverStatus AlarmStatus
  timingGeneratorActiveStatus INTEGER
  timingGeneratorT0CurrentQuality INTEGER
  timingGeneratorT4CurrentQuality INTEGER
  timingGeneratorT4MinimumQuality INTEGER
  timingGeneratorT0PreferredSource OBJECT IDENTIFIER
  timingGeneratorT4PreferredSource OBJECT IDENTIFIER
  timingGeneratorRowStatus RowStatus

TimingGeneratorMaintRecord  
SEQUENCE    
  timingGeneratorT4Squelch INTEGER
  timingGeneratorStatusControl INTEGER
  timingGeneratorT0ForcedSource OBJECT IDENTIFIER
  timingGeneratorT4ForcedSource OBJECT IDENTIFIER
  timingGeneratorWtrClearSource OBJECT IDENTIFIER

TimingSink  
SEQUENCE    
  timingSinkGenId Integer32
  timingSinkId Integer32
  timingSinkType INTEGER
  timingSinkIfIndex InterfaceIndexOrZero
  timingSinkSelector Integer32
  timingSinkPriority INTEGER
  timingSinkLabel DisplayString
  timingSinkLosAlarm AlarmStatus
  timingSinkDriftAlarm AlarmStatus
  timingSinkActiveStatus INTEGER
  timingSinkCurrentQuality INTEGER
  timingSinkOverwriteTxQuality INTEGER
  timingSinkOverwriteRxQuality INTEGER
  timingSinkSentQuality INTEGER
  timingSinkE1Sabit INTEGER
  timingSinkEthPortRole INTEGER
  timingSinkRowStatus RowStatus

TimingSinkSelector  
SEQUENCE    
  timingSinkSelectorId Integer32
  timingSinkSelectorLabel DisplayString

EsmcRecord  
SEQUENCE    
  esmcSsmEnable INTEGER
  esmcQlRx INTEGER
  esmcQlTx INTEGER
  esmcPktsRx Counter32
  esmcPktsTx Counter32
  esmcPktsRxDropped Counter32
  esmcPktsRxErrored Counter32
  esmc1000BaseTRole INTEGER
  esmcRowStatus RowStatus

Defined Values

sync 1.3.6.1.4.1.3373.1103.28
Timing Source Management.
MODULE-IDENTITY    

syncMibVersion 1.3.6.1.4.1.3373.1103.28.1
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

timingGeneratorTable 1.3.6.1.4.1.3373.1103.28.2
Table with TimingGenerator records.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TimingGenerator

timingGeneratorRecord 1.3.6.1.4.1.3373.1103.28.2.1
TimingGenerator record.
Status: current Access: not-accessible
OBJECT-TYPE    
  TimingGenerator  

timingGeneratorId 1.3.6.1.4.1.3373.1103.28.2.1.1
This object is used as Index of the Timing Generator Table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

timingGeneratorT4vsT0 1.3.6.1.4.1.3373.1103.28.2.1.2
This object is used to set or reset the condition T4 equal T0.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER t4NotEqualT0(1), t4EqualT0(2)  

timingGeneratorHoldOffTime 1.3.6.1.4.1.3373.1103.28.2.1.3
HoldOff time in milliseconds (300..1800).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 300..1800  

timingGeneratorWtrTime 1.3.6.1.4.1.3373.1103.28.2.1.4
Wait Time to Restore in minutes (0..12).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..12  

timingGeneratorSinkLosSet 1.3.6.1.4.1.3373.1103.28.2.1.5
Wait time (seconds) before to set Los of reference signal.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..60  

timingGeneratorSinkLosReset 1.3.6.1.4.1.3373.1103.28.2.1.6
Wait time (seconds) before to reset Los of reference signal.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..60  

timingGeneratorT0SquelchAlarm 1.3.6.1.4.1.3373.1103.28.2.1.7
T0 squelch Alarm (Probable cause = xxx) with associated severity.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmStatus  

timingGeneratorT4SquelchAlarm 1.3.6.1.4.1.3373.1103.28.2.1.8
T4 squelch Alarm (Probable cause = xxx) with associated severity.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmStatus  

timingGeneratorFreeRunningStatus 1.3.6.1.4.1.3373.1103.28.2.1.9
Free running status (Probable cause = xxx) with associated severity.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmStatus  

timingGeneratorHoldoverStatus 1.3.6.1.4.1.3373.1103.28.2.1.10
Holdover status (Probable cause = xxx) with associated severity.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmStatus  

timingGeneratorActiveStatus 1.3.6.1.4.1.3373.1103.28.2.1.11
Active status (Probable cause = xxx) with associated severity.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cleared(1), activeReportableStatus(2)  

timingGeneratorT0CurrentQuality 1.3.6.1.4.1.3373.1103.28.2.1.12
Current quality on T0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)  

timingGeneratorT4CurrentQuality 1.3.6.1.4.1.3373.1103.28.2.1.13
Current quality on T4.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)  

timingGeneratorT4MinimumQuality 1.3.6.1.4.1.3373.1103.28.2.1.14
If the Quality Level of the signal used to derive T4 falls below timingGeneratorT4MinimumQuality then the output will be squelched. The value ql-DNU inhibits T4 squelch due to this minimum Quality Level. This feature is enabled by timingGeneratorT4Squelch when timingGeneratorQualityEnable is on(2).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER qPRC(2), qSSUT(4), qSSUL(8), qSEC(11)  

timingGeneratorT0PreferredSource 1.3.6.1.4.1.3373.1103.28.2.1.15
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as preferential clock source of T0. If no preferential timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
Status: current Access: read-create
OBJECT-TYPE    
  OBJECT IDENTIFIER  

timingGeneratorT4PreferredSource 1.3.6.1.4.1.3373.1103.28.2.1.16
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as preferential clock source of T4. If no preferential timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
Status: current Access: read-create
OBJECT-TYPE    
  OBJECT IDENTIFIER  

timingGeneratorRowStatus 1.3.6.1.4.1.3373.1103.28.2.1.17
Status of this row of timingGeneratorTable.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

timingGeneratorMaintTable 1.3.6.1.4.1.3373.1103.28.3
Table with TimingGenerator records.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TimingGeneratorMaintRecord

timingGeneratorMaintRecord 1.3.6.1.4.1.3373.1103.28.3.1
TimingGenerator record.
Status: current Access: not-accessible
OBJECT-TYPE    
  TimingGeneratorMaintRecord  

timingGeneratorT4Squelch 1.3.6.1.4.1.3373.1103.28.3.1.1
This object is used to enable/disable T4 squelch.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

timingGeneratorStatusControl 1.3.6.1.4.1.3373.1103.28.3.1.2
Clock generator operating mode control. This item is linked to a manual operation (ManOpRecord) instance.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER freerunning(1), holdover(2), locked(3)  

timingGeneratorT0ForcedSource 1.3.6.1.4.1.3373.1103.28.3.1.3
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as forced clock source of T0. If no forced timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
Status: current Access: read-write
OBJECT-TYPE    
  OBJECT IDENTIFIER  

timingGeneratorT4ForcedSource 1.3.6.1.4.1.3373.1103.28.3.1.4
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as forced clock source of T4. If no forced timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
Status: current Access: read-write
OBJECT-TYPE    
  OBJECT IDENTIFIER  

timingGeneratorWtrClearSource 1.3.6.1.4.1.3373.1103.28.3.1.5
Object identifier of the leaf timingSinkGenId of the timingSink instance selected to clear WTR time. On read, this object return alvays an OBJECT IDENTIFIER {0 0}.
Status: current Access: read-write
OBJECT-TYPE    
  OBJECT IDENTIFIER  

timingSinkTable 1.3.6.1.4.1.3373.1103.28.4
Table with TimingSink records.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TimingSink

timingSinkRecord 1.3.6.1.4.1.3373.1103.28.4.1
TimingSink record.
Status: current Access: not-accessible
OBJECT-TYPE    
  TimingSink  

timingSinkGenId 1.3.6.1.4.1.3373.1103.28.4.1.1
This object is used as Index of the timingGeneratorTable and defines in union with timingSinkType and timingSinkId the reference signal.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

timingSinkId 1.3.6.1.4.1.3373.1103.28.4.1.2
This object is used as Index of the timingSinkTable and defines in union with timingSinkType and timingSinkGenId the reference signal.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

timingSinkType 1.3.6.1.4.1.3373.1103.28.4.1.3
This object is used as Index of the timingSinkTable and defines if the reference signal is used to generate T0 or T4 system clock.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER t0(1), t4(2)  

timingSinkIfIndex 1.3.6.1.4.1.3373.1103.28.4.1.4
The ifIndex value the agent selected for this timingSink interface.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndexOrZero  

timingSinkSelector 1.3.6.1.4.1.3373.1103.28.4.1.5
This object is used to select one of the possible clock source connected to this timingSink. Valid values are listed in timingSinkSelectorTable: only values of timingSinkSelectorId related to this instance of timinkSinkRecord are accepted. Only the values corresponding to the index timingSinkSelectorId of timinkSinkSelectorTable related to this instance of timinkSinkRecord will be accepted.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

timingSinkPriority 1.3.6.1.4.1.3373.1103.28.4.1.6
This object is used to set the priority of the reference signal (p1 is the highest priority).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER p1(1), p2(2), p3(3), p4(4), p5(5), p6(6), p7(7), p8(8), p9(9), p10(10), p11(11), p12(12), p13(13), p14(14), p15(15), disable(16)  

timingSinkLabel 1.3.6.1.4.1.3373.1103.28.4.1.7
ASCII string used to describe the reference signal when a trap is sent.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

timingSinkLosAlarm 1.3.6.1.4.1.3373.1103.28.4.1.8
Loss of reference signal (Probable cause = xxx) alarm with associated severity.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmStatus  

timingSinkDriftAlarm 1.3.6.1.4.1.3373.1103.28.4.1.9
Drift of reference signal (Probable cause = xxx) alarm with associated severity.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmStatus  

timingSinkActiveStatus 1.3.6.1.4.1.3373.1103.28.4.1.10
Active status (Probable cause = xxx) status for the reference signal.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cleared(1), activeReportableStatus(2)  

timingSinkCurrentQuality 1.3.6.1.4.1.3373.1103.28.4.1.11
Current quality on sink instance.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)  

timingSinkOverwriteTxQuality 1.3.6.1.4.1.3373.1103.28.4.1.12
Forcing of Tx quality parameter.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noOverwrite(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)  

timingSinkOverwriteRxQuality 1.3.6.1.4.1.3373.1103.28.4.1.13
Forcing of Rx quality parameter.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noOverwrite(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)  

timingSinkSentQuality 1.3.6.1.4.1.3373.1103.28.4.1.14
Quality level written in the S1 byte of the outgoing STM-n.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)  

timingSinkE1Sabit 1.3.6.1.4.1.3373.1103.28.4.1.15
Specifies the San synchronization status bit used to indicate the clock quality level. Meaningful when the Sink source is an E1
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 4..8  

timingSinkEthPortRole 1.3.6.1.4.1.3373.1103.28.4.1.16
This item configures how to handle the role of a 1000BASE-T port when it is used as a source of timing: choosing 'static', the role is set according ethLanPhyTable settings, choosing 'dynamic', the role is set consistently with the timing direction over the 1000baseT link chosen by SSM protocol.
Status: deprecated Access: read-create
OBJECT-TYPE    
  INTEGER static(1), dynamic(2)  

timingSinkRowStatus 1.3.6.1.4.1.3373.1103.28.4.1.17
Status of this row of timingSinkTable
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

timingGeneratorManualSwitch 1.3.6.1.4.1.3373.1103.28.5
timingGeneratorId of the forced timingGenerator instance. If no preferred timing generator is selected, the value should be set to 0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

timingGeneratorForcedSwitch 1.3.6.1.4.1.3373.1103.28.6
timingGeneratorId of the forced timingGenerator instance. If no forced timing generator is selected, the value should be set to 0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

timingGeneratorT0SquelchAlarmSeverityCode 1.3.6.1.4.1.3373.1103.28.7
Defines the severity associated to the TimingGeneratorT0SquelchAlarm and enables/disables the trap generation on status change event.
Status: current Access: read-write
OBJECT-TYPE    
  AlarmSeverityCode  

timingGeneratorT4SquelchAlarmSeverityCode 1.3.6.1.4.1.3373.1103.28.8
Defines the severity associated to the timingGeneratorT4SquelchAlarm and enables/disables the trap generation on status change event.
Status: current Access: read-write
OBJECT-TYPE    
  AlarmSeverityCode  

timingGeneratorFreeRunningStatusSeverityCode 1.3.6.1.4.1.3373.1103.28.9
Defines the severity associated to the timingGeneratorFreeRunningStatus and enables/disables the trap generation on status change event.
Status: current Access: read-write
OBJECT-TYPE    
  AlarmSeverityCode  

timingGeneratorHoldoverStatusSeverityCode 1.3.6.1.4.1.3373.1103.28.10
Defines the severity associated to the timingGeneratorHoldoverStatus and enables/disables the trap generation on status change event.
Status: current Access: read-write
OBJECT-TYPE    
  AlarmSeverityCode  

timingGeneratorActiveStatusSeverityCode 1.3.6.1.4.1.3373.1103.28.11
Defines the severity associated to the timingGeneratorActiveStatus and enables/disables the trap generation on status change event.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), statusTrapEnable(2)  

timingGeneratorQualityEnable 1.3.6.1.4.1.3373.1103.28.12
Quality policy enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

timingSinkLosAlarmSeverityCode 1.3.6.1.4.1.3373.1103.28.13
Defines the severity associated to the TimingSinkLosAlarm and enables/disables the trap generation on status change event.
Status: current Access: read-write
OBJECT-TYPE    
  AlarmSeverityCode  

timingSinkDriftAlarmSeverityCode 1.3.6.1.4.1.3373.1103.28.14
Defines the severity associated to the TimingSinkDriftAlarm and enables/disables the trap generation on status change event.
Status: current Access: read-write
OBJECT-TYPE    
  AlarmSeverityCode  

timingSinkActiveStatusSeverityCode 1.3.6.1.4.1.3373.1103.28.15
Defines the severity associated to the timingSinkActiveStatus and enables/disables the trap generation on status change event.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), statusTrapEnable(2)  

timingSinkSelectorTable 1.3.6.1.4.1.3373.1103.28.16
Table with TimingSinkSelector records.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TimingSinkSelector

timingSinkSelectorRecord 1.3.6.1.4.1.3373.1103.28.16.1
TimingSinkSelector entry. Several instances of this entry can be create for each instance of timingSinkTable. Each entry represents a possible source selected by a multiplexer outside the SETS for a specific timingSink. Only the values corresponding to the index timingSinkSelectorId can be set to timingSinkSelector.
Status: current Access: not-accessible
OBJECT-TYPE    
  TimingSinkSelector  

timingSinkSelectorId 1.3.6.1.4.1.3373.1103.28.16.1.1
This object is used as Index of the timingSinkSelectorTable and defines in union with timingSinkGenId, timingSinkType and timingSinkId the selected source by a multiplexer outside the SETS.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

timingSinkSelectorLabel 1.3.6.1.4.1.3373.1103.28.16.1.2
ASCII string used to describe the selectable timing source.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

esmcTable 1.3.6.1.4.1.3373.1103.28.17
Table with TimingSinkSelector records.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EsmcRecord

esmcRecord 1.3.6.1.4.1.3373.1103.28.17.1
esmcTable entry. Every entries describes an ESMC channel of a TE interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  EsmcRecord  

esmcSsmEnable 1.3.6.1.4.1.3373.1103.28.17.1.1
This object enables SSM messaging on this ifIndex.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

esmcQlRx 1.3.6.1.4.1.3373.1103.28.17.1.2
This object show quality received on ESMC-PDU this interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)  

esmcQlTx 1.3.6.1.4.1.3373.1103.28.17.1.3
This object show quality transmitted in ESMC-PDU on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)  

esmcPktsRx 1.3.6.1.4.1.3373.1103.28.17.1.4
This object contains the total number of received ESMC-PDU packets on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

esmcPktsTx 1.3.6.1.4.1.3373.1103.28.17.1.5
This object contains the total number of transmitted ESMC-PDU packets on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

esmcPktsRxDropped 1.3.6.1.4.1.3373.1103.28.17.1.6
This object contains the total number of dropped ESMC-PDU packets on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

esmcPktsRxErrored 1.3.6.1.4.1.3373.1103.28.17.1.7
This object contains the total number of dropped ESMC-PDU packets whose processing(decoding) resulted into error.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

esmc1000BaseTRole 1.3.6.1.4.1.3373.1103.28.17.1.8
This object allows to input the clock generator role of a 1000BaseT interface. This objects is applicable when the quality management is disabled (timingGeneratorQualityEnable set to off(1)) and to all interfaces not connected to any timingSink when the quality management is enabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER slave(1), master(2), auto(3)  

esmcRowStatus 1.3.6.1.4.1.3373.1103.28.17.1.9
Status of this row of esmcTable.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus