SHE-SELT-MIB
File:
SHE-SELT-MIB.mib (17850 bytes)
Imported modules
Imported symbols
Defined Types
SheSeltServerInfoConnectStateType |
|
The connection type between CXU and SELT server. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
sheSeltServerConnected(1), sheSeltServerDisconnected(2) |
|
SheSeltServerControlReqType |
|
The type for SELT connection control commands. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
seltConfigSeltServer(1), seltConnectSeltServer(2), seltDisconnectSeltServer(3) |
|
SheSeltServerControlReqResultType |
|
The result type for SELT connection control commands. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
seltControlServerReqNotSupported(4), commExecStarted(30), paramFaulty(31), requestBusy(32), setDataFailed(34), aswTimeout(35), commandFailed(36), commandSucceeded(37) |
|
SheSeltTestRequestIfStateType |
|
The state type of port (IfIndex). |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
sheSeltStatusIfBeingTested(1), sheSeltStatusIfBeingIdle(2) |
|
SheSeltTestRequestIuStateType |
|
The state type of IU (IuIndex). |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
sheSeltStatusIuBeingTested(1), sheSeltStatusIuBeingIdle(2) |
|
SheSeltTestRequestControlReqResultType |
|
The result type for SELT test command. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
seltRequestControlReqNotSupported(2), commExecStarted(30), paramFaulty(31), requestBusy(32), setDataFailed(34), aswTimeout(35), commandFailed(36), commandSucceeded(37), seltStopNotSupported(38) |
|
SheSeltTestRequestIfStateEntry |
|
SEQUENCE |
|
|
|
|
sheSeltTestRequestIfIndex |
InterfaceIndex |
|
|
sheSeltTestRequestIfState |
SheSeltTestRequestIfStateType |
|
|
sheSeltTestRequestIuState |
SheSeltTestRequestIuStateType |
|
|
sheSeltTestRequestIfFDRCollectionEnableState |
SheSeltTestRequestControlReqFDRCollectionEnableType |
|
|
sheSeltTestRequestIfFDRCollectionNumAverageState |
INTEGER |
|
Defined Values
sheSelt |
1.3.6.1.4.1.231.7.1.2.1.23 |
Definition of selt feature control command |
MODULE-IDENTITY |
|
|
|
sheSeltServerControlReq |
1.3.6.1.4.1.231.7.1.2.1.23.2.1 |
Control connection between CXU and SELT server(config SELT server IP address and service port,
connect CXU to SELT server and disconnect CXU with SELT server.SELT server is used to receive
and collect selt raw data from plugin unit IU throuth CXU, to calculate and then to send selt result to CXU,
so before doing selt test,SELT server must be configed and connected.A config command is permanent
unless we need to change SELT sever's IP address or service port.A connect command supports all IU's
selt test unless the connection is close for some reasons. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
SheSeltServerControlReqType |
|
|
sheSeltServerControlTimer |
1.3.6.1.4.1.231.7.1.2.1.23.2.5 |
The maximum wait time for the manager for a long running user command. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
sheSeltTestRequestIfStateEntry |
1.3.6.1.4.1.231.7.1.2.1.23.3.1.1 |
An entry in sheSeltStatusIfTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SheSeltTestRequestIfStateEntry |
|
|
sheSeltTestRequestIfIndex |
1.3.6.1.4.1.231.7.1.2.1.23.3.1.1.1 |
IfIndex: the Index of port(such as: 101, 102...172; 201, 202...272; ...)
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
100..2000 |
|
sheSeltTestRequestIfState |
1.3.6.1.4.1.231.7.1.2.1.23.3.1.1.2 |
The selt test status of port (IfIndex).
If current port is under selt test, its sheSeltTestRequestIfState = sheSeltStatusIfBeingTested,
otherwise its sheSeltTestRequestIfState = sheSeltStatusIfBeingIdle.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SheSeltTestRequestIfStateType |
|
|
sheSeltTestRequestIuState |
1.3.6.1.4.1.231.7.1.2.1.23.3.1.1.3 |
The selt test status of IU of this port.
Every port must know whether this IU is under selt test or not,
in order to decide if the selt test request on this port can be accepted.
If any port of its IU is under selt test,
sheSeltTestRequestIuState = sheSeltStatusIuBeingTested;
If all ports are not under selt test,
sheSeltTestRequestIuState = sheSeltStatusIuBeingIdle
For example:
If port 101 is under selt test,
sheSeltTestRequestIuState of 101 and 102 are both sheSeltStatusIuBeingTested.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SheSeltTestRequestIuStateType |
|
|
sheSeltTestRequestIfFDRCollectionNumAverageState |
1.3.6.1.4.1.231.7.1.2.1.23.3.1.1.5 |
The value of FDRCollectionNumAverage for this port, if it is under selt test.
If this port is not under selt test, return 0.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..65535 |
|
sheSeltTestRequestControlReq |
1.3.6.1.4.1.231.7.1.2.1.23.4.1 |
Controls CXU to send doing selt test to IU for a specified subscriber's loop.Note that
simultaneous tests of subscriber's loop on different IUs are allowed, but simultaneous tests
of different subscribers' loops on the same IU are not allowed. When IU received the command
it'll begin to process and send raw data to CXU,then to SELT server. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
SheSeltTestRequestControlReqType |
|
|
sheSeltTestRequestControlTimer |
1.3.6.1.4.1.231.7.1.2.1.23.4.5 |
The maximum wait time for the manager for a long running user command. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
sheSeltTestRequestControlReqFDRCollectionNumAverage |
1.3.6.1.4.1.231.7.1.2.1.23.4.9 |
This parameter is specific for Infineon line card, but
not for Conexant line card.
This parameter is to set the number of average for FDR Data
Collection when sheSeltTestRequestControlReqFDRCollectionEnable
is Enable(1). When sheSeltTestRequestControlReqFDRCollectionEnable
is Disable(0), this one will be igored.
The range of this one is [1, 65535], and the default value is 1024.
With this default number of averages, a single data collection
will take approximately 90 seconds. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..65535 |
|
sheSeltServerControlResultEvent |
1.3.6.1.4.1.231.7.1.2.1.23.5.1 |
Succeeded or failed to connect with SELT server. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
sheSeltTestRequestControlResultEvent |
1.3.6.1.4.1.231.7.1.2.1.23.5.2 |
Succeeded or failed to execute the command of selt request. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
sheSeltReceivedRawDataEvent |
1.3.6.1.4.1.231.7.1.2.1.23.5.3 |
Having received raw data from IU. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
sheSeltNoReceivedRawDataEvent |
1.3.6.1.4.1.231.7.1.2.1.23.5.4 |
Having not received raw data from IU. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
sheSeltGroup |
1.3.6.1.4.1.231.7.1.2.1.23.100.1.1 |
A collection of objects providing information about
a VDSL Line. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
sheSeltControlGroup |
1.3.6.1.4.1.231.7.1.2.1.23.100.1.2 |
Description. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
sheSeltNotificationGroup |
1.3.6.1.4.1.231.7.1.2.1.23.100.1.3 |
This group supports notifications of significant
conditions associated with physical objects. |
Status: current |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|
sheSeltMibCompliance |
1.3.6.1.4.1.231.7.1.2.1.23.100.2.1 |
Description. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|