JuiceBoxPortEntry |
|
SEQUENCE |
|
|
|
|
juiceBoxPortIndex |
Integer32 |
|
|
juiceBoxPortDetectionSetting |
INTEGER |
|
|
juiceBoxPortMaxPower |
INTEGER |
|
|
juiceBoxPortDescription |
SnmpAdminString |
|
|
juiceBoxPortStatus |
INTEGER |
|
|
juiceBoxPortClassifications |
INTEGER |
|
|
juiceBoxPortPowerDelivered |
Gauge32 |
|
juiceBoxPortEntry |
1.3.6.1.4.1.20364.1.1.1.1 |
A set of objects that display and control the power
characteristics of a Juice Box Midspan Power Hub port. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
JuiceBoxPortEntry |
|
|
juiceBoxPortMaxPower |
1.3.6.1.4.1.20364.1.1.1.1.3 |
Describes the maximum power setting for the port in watts.
This setting is used by to calculate Allocated Power.
It is only used if the port is classified as Class 0 or Legacy. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
max1W(1), max2W(2), max3W(3), max4W(4), max5W(5), max6W(6), max7W(7), max8W(8), max9W(9), max10W(10), max11W(11), max12W(12), max13W(13), max14W(14), max15W(15) |
|
juiceBoxPortStatus |
1.3.6.1.4.1.20364.1.1.1.1.5 |
Describes the status of the port.
A value of disabled(1) means that juiceBoxPortDetectionSetting for the port
is set to disabled. No PD detection will be performed.
A value of deliveringPower(2) means the port is delivering power within
operational parameters.
A value of startupFault(3) means that port failed to power up properly.
A value of overCurrentFault(4) means the port current was greater than the
350mA maximum value specified by IEEE 802.3af.
A value of short(5) means an short circuit was discovered during PD detection.
A value of open(6) means an open circuit was discovered during PD detection.
A value of rsignatureHi(7) means a resistance greater than the valid signature
specified by IEEE 802.3af was discovered during PD detection.
A value of rsignatureLow(8) means a resistance less than the valid signature
specified by IEEE 802.3af was discovered during PD detection.
A value of invalidDetect(9) means an invalid signature as
specified by IEEE 802.3af was discovered during PD detection.
A value of disconnect(10) means that the port current was less than the
10mA mininum value specified by IEEE 802.3af required to maintain power.
A value of powerup(12) means the port is in the process of being powered.
A value of overPowerWarning(13) means the port is delivering power greater
than the maximum value for its Class or the value set with juiceBoxPortMaxPower.
A value of overPowerFault(14) means the port was shut down because the power delivered
was at least 1 Watt greater than the maximum value for its Class or the value set
with juiceBoxPortMaxPower.
A value of insufficientPower(15) means the port could not be powered because
there is insuffiecent power capability remaining to fully power the port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), deliveringPower(2), startupFault(3), overCurrentFault(4), short(5), open(6), rsignatureHi(7), rsignatureLow(8), invalidDetect(9), disconnect(10), powerup(12), overPowerWarning(13), overPowerFault(14), insufficientPower(15) |
|
juiceBoxMainSystemVoltage |
1.3.6.1.4.1.20364.1.1.2.1 |
Measured system voltage in millivolts . |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
juiceBoxMainTemperature |
1.3.6.1.4.1.20364.1.1.2.2 |
Measured internal temperature in degrees C. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
juiceBoxMainPowerAvailable |
1.3.6.1.4.1.20364.1.1.2.3 |
The nominal power of the JuiceBox expressed in Watts. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
1..65535 |
|
juiceBoxMainPowerDelivered |
1.3.6.1.4.1.20364.1.1.2.4 |
Total Power Delivered to the PDs. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
juiceBoxMainAllocatedPower |
1.3.6.1.4.1.20364.1.1.2.5 |
Total Power Allocated to the PDs. This value is calculated base
on the Classification of the PDs powered by the Juice Box. If the PD
classified as Class 0 or Legacy, the juiceBoxPortMaxPower setting for
the port is used. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
juiceBoxMainAllocatedPowerThreshold |
1.3.6.1.4.1.20364.1.1.2.6 |
The usage threshold expressed in percents for
comparing the alocated power and initiating
an alarm (trap) if the threshold is exceeded. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..99 |
|
juiceBoxMainTrapDestinationIPAddr |
1.3.6.1.4.1.20364.1.1.2.7 |
A read/write IP address. This is the address to which
the agent sends traps. The value is initialized as 0.0.0.0.
Traps will not be sent until a new value is entered |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
juiceBoxMainTrapReXmitPeriod |
1.3.6.1.4.1.20364.1.1.2.8 |
The period of time in seconds after which a trap will be
re-transmitted if the fault condition is still present |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..3600 |
|
juiceBoxMainGlobalPortDetectionSetting |
1.3.6.1.4.1.20364.1.1.2.9 |
Sets the PortDetectionSetting for all the Juice Box ports to the
selected value.
Describes the type of PD detection performed by the port.
A value of disabled(1) means that no PD detection is performed. If a port
currently delivering power is set to disabled(1), power will be removed
from the port.
A value of ieee802.3afonly(2) means only PDs with valid signatures
as defined by ieee 802.3af will be detected and powered.
A value of ieee8023afandlegacy(3) means that PDs with 802.3af and legacy
signatures will be detected and powered.
A value of forcedon(4) means the port is powered without regard to detection status.
A setting of forcedon(4) is not persistent and must be re-asserted after restart/reboot |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), ieee8023afonly(2), ieee8023afandlegacy(3), forcedon(4) |
|
juiceBoxMainGlobalPortMaxPower |
1.3.6.1.4.1.20364.1.1.2.10 |
Used to set PortMaxPower for all ports to the same value.
Describes the maximum power setting for the port in watts.
This setting is used by to calculate Allocated Power.
It is only used if the port is classified as Class 0 or Legacy. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
max1W(1), max2W(2), max3W(3), max4W(4), max5W(5), max6W(6), max7W(7), max8W(8), max9W(9), max10W(10), max11W(11), max12W(12), max13W(13), max14W(14), max15W(15) |
|
juiceBoxMainNetworkControllerFirmware |
1.3.6.1.4.1.20364.1.1.2.11 |
Firmware Version of the JuiceBox Network Controller. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SnmpAdminString |
|
|
juiceBoxMainSystemControllerFirmware |
1.3.6.1.4.1.20364.1.1.2.12 |
Firmware Version of the JuiceBox SystemController. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SnmpAdminString |
|
|