RUCKUS-SYSTEM-MIB

File: RUCKUS-SYSTEM-MIB.mib (7426 bytes)

Imported modules

RUCKUS-ROOT-MIB SNMPv2-TC SNMPv2-CONF
RFC1155-SMI SNMPv2-SMI

Imported symbols

ruckusCommonSystemModule TruthValue DisplayString
OBJECT-GROUP MODULE-COMPLIANCE Gauge
MODULE-IDENTITY OBJECT-TYPE Unsigned32

Defined Values

ruckusSystemMIB 1.3.6.1.4.1.25053.1.1.11.1
Ruckus system objects.
MODULE-IDENTITY    

ruckusSystemObjects 1.3.6.1.4.1.25053.1.1.11.1.1
OBJECT IDENTIFIER    

ruckusSystemInfo 1.3.6.1.4.1.25053.1.1.11.1.1.1
OBJECT IDENTIFIER    

ruckusSystemServices 1.3.6.1.4.1.25053.1.1.11.1.1.2
OBJECT IDENTIFIER    

ruckusSystemCommands 1.3.6.1.4.1.25053.1.1.11.1.1.3
OBJECT IDENTIFIER    

ruckusSystemEvents 1.3.6.1.4.1.25053.1.1.11.1.2
OBJECT IDENTIFIER    

ruckusSystemCPUUtil 1.3.6.1.4.1.25053.1.1.11.1.1.1.1
CPU utilization.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

ruckusSystemMemoryUtil 1.3.6.1.4.1.25053.1.1.11.1.1.1.2
Memory utilization.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

ruckusSystemCPUModel 1.3.6.1.4.1.25053.1.1.11.1.1.1.4
CPU Model
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ruckusSystemtCPUSpeed 1.3.6.1.4.1.25053.1.1.11.1.1.1.5
CPU Speed
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ruckusSystemFlashSize 1.3.6.1.4.1.25053.1.1.11.1.1.1.9
Total flash size in KByte.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge  

ruckusSystemMemSize 1.3.6.1.4.1.25053.1.1.11.1.1.1.10
Total memory size in Byte.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge  

ruckusSystemOSType 1.3.6.1.4.1.25053.1.1.11.1.1.1.30
OS Type.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

ruckusSystemHTTP 1.3.6.1.4.1.25053.1.1.11.1.1.2.1
OBJECT IDENTIFIER    

ruckusSystemHTTPS 1.3.6.1.4.1.25053.1.1.11.1.1.2.2
OBJECT IDENTIFIER    

ruckusSystemTelnet 1.3.6.1.4.1.25053.1.1.11.1.1.2.3
OBJECT IDENTIFIER    

ruckusSystemSSH 1.3.6.1.4.1.25053.1.1.11.1.1.2.4
OBJECT IDENTIFIER    

ruckusSystemBonjour 1.3.6.1.4.1.25053.1.1.11.1.1.2.5
OBJECT IDENTIFIER    

ruckusSystemSyslog 1.3.6.1.4.1.25053.1.1.11.1.1.2.6
OBJECT IDENTIFIER    

ruckusSystemNTP 1.3.6.1.4.1.25053.1.1.11.1.1.2.7
OBJECT IDENTIFIER    

ruckusSystemFlexMaster 1.3.6.1.4.1.25053.1.1.11.1.1.2.8
OBJECT IDENTIFIER    

ruckusSystemHTTPStatus 1.3.6.1.4.1.25053.1.1.11.1.1.2.1.1
Enable/disable HTTP service.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ruckusSystemHTTPSStatus 1.3.6.1.4.1.25053.1.1.11.1.1.2.2.1
Enable/disable HTTPS service.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ruckusSystemTelnetStatus 1.3.6.1.4.1.25053.1.1.11.1.1.2.3.1
Enable/disable Telnet service.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ruckusSystemSSHStatus 1.3.6.1.4.1.25053.1.1.11.1.1.2.4.1
Enable/disable SSH service.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ruckusSystemBonjourStatus 1.3.6.1.4.1.25053.1.1.11.1.1.2.5.1
Enable/disable Bonjour service.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ruckusSystemSyslogStatus 1.3.6.1.4.1.25053.1.1.11.1.1.2.6.1
Enable/disable Syslog service.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ruckusSystemSyslogServerIP 1.3.6.1.4.1.25053.1.1.11.1.1.2.6.2
IP(v4 or v6) of syslog server.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2..40)  

ruckusSystemSyslogServerPort 1.3.6.1.4.1.25053.1.1.11.1.1.2.6.3
Port of syslog server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

ruckusSystemNTPStatus 1.3.6.1.4.1.25053.1.1.11.1.1.2.7.1
Enable/disable NTP service.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ruckusSystemNTPGMTTime 1.3.6.1.4.1.25053.1.1.11.1.1.2.7.2
GMT time.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ruckusSystemNTPActiveServer 1.3.6.1.4.1.25053.1.1.11.1.1.2.7.3
Active NTP server.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..128)  

ruckusSystemNTPUpdate 1.3.6.1.4.1.25053.1.1.11.1.1.2.7.4
Update GMT time.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

ruckusSystemFlexMasterURL 1.3.6.1.4.1.25053.1.1.11.1.1.2.8.1
Config FlexMaster server URL. URL start with 'http://' or 'https://'
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..128)  

ruckusSystemReboot 1.3.6.1.4.1.25053.1.1.11.1.1.3.1
Reboot.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ruckusSystemSetFactory 1.3.6.1.4.1.25053.1.1.11.1.1.3.2
Set factory default.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ruckusSystemDHCPRenew 1.3.6.1.4.1.25053.1.1.11.1.1.3.3
Renew DHCP IP.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue