RS366-OPT-MIB

File: RS366-OPT-MIB.mib (11325 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

enterprises OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

Cdx6500PPCTRS366PortEntry  
SEQUENCE    
  cdx6500RS366CfgPortNumber INTEGER
  cdx6500RS366CfgADataPortNumber INTEGER
  cdx6500RS366CfgContXferMode INTEGER
  cdx6500RS366CfgMaxAddrDigits INTEGER
  cdx6500RS366CfgMaxRespTime INTEGER
  cdx6500RS366CfgElectricalInterfaceType INTEGER
  cdx6500RS366CfgV24ElectricalInterfaceOption INTEGER
  cdx6500RS366CfgHighSpeedElectricalInterfaceOption INTEGER

Cdx6500PPSTRS366PortEntry  
SEQUENCE    
  cdx6500RS366StatPortNumber INTEGER
  cdx6500RS366StatPortStatus DisplayString
  cdx6500RS366StatPortState DisplayString
  cdx6500RS366StatDataNum INTEGER
  cdx6500RS366StatTotalCalls INTEGER
  cdx6500RS366StatFailedCalls INTEGER
  cdx6500RS366StatTotalTimeouts INTEGER
  cdx6500RS366StatTotalIllegalDigits INTEGER
  cdx6500RS366StatPortConnected DisplayString

Defined Values

codex 1.3.6.1.4.1.449
OBJECT IDENTIFIER    

cdxProductSpecific 1.3.6.1.4.1.449.2
OBJECT IDENTIFIER    

cdx6500 1.3.6.1.4.1.449.2.1
OBJECT IDENTIFIER    

cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
OBJECT IDENTIFIER    

cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
OBJECT IDENTIFIER    

cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
OBJECT IDENTIFIER    

cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
OBJECT IDENTIFIER    

cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
OBJECT IDENTIFIER    

cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
OBJECT IDENTIFIER    

cdx6500Controls 1.3.6.1.4.1.449.2.1.4
OBJECT IDENTIFIER    

cdx6500PPCTRS366PortTable 1.3.6.1.4.1.449.2.1.2.1.1.21
A list of RS366 Port configuration entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPCTRS366PortEntry

cdx6500PPCTRS366PortEntry 1.3.6.1.4.1.449.2.1.2.1.1.21.1
An RS366 Configuration Table entry. Each entry contains the configuration parameters for a single RS366 port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPCTRS366PortEntry  

cdx6500RS366CfgPortNumber 1.3.6.1.4.1.449.2.1.2.1.1.21.1.1
Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..52  

cdx6500RS366CfgADataPortNumber 1.3.6.1.4.1.449.2.1.2.1.1.21.1.2
Associated Data Port Number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500RS366CfgContXferMode 1.3.6.1.4.1.449.2.1.2.1.1.21.1.3
modeEon - Transfer control after end of number digit detected. modeEbt - Transfer control after maximum address digits accumulated and answerback tone is received. newvalModeNull - same functionality as 'modeNull', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER modenull(0), modeeon(1), modeebt(2), newvalmodenull(50)  

cdx6500RS366CfgMaxAddrDigits 1.3.6.1.4.1.449.2.1.2.1.1.21.1.4
Number of digits required to transfer control in EBT mode. This parameter is not required in EON mode and it is set to 15 irrespective of the user entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..15  

cdx6500RS366CfgMaxRespTime 1.3.6.1.4.1.449.2.1.2.1.1.21.1.5
Maximum EIA response time in seconds before a timeout can occur. sec0 - Indicates response time out should be disabled. sec32 - Maximum EIA response time is 32 seconds. sec48 - Maximum EIA response time is 48 seconds. sec96 - Maximum EIA response time is 96 seconds. newvalSec0 - same functionality as 'sec0', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sec0(0), sec32(32), sec48(48), sec96(96), newvalSec0(50)  

cdx6500RS366CfgElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.21.1.6
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v24(1), v35(2), v36(3), x21(4), none(5)  

cdx6500RS366CfgV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.21.1.7
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ri(1), tm(2)  

cdx6500RS366CfgHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.21.1.8
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), xover(2)  

cdx6500PPSTRS366PortTable 1.3.6.1.4.1.449.2.1.3.1.1.22
A list of RS366 Port statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTRS366PortEntry

cdx6500PPSTRS366PortEntry 1.3.6.1.4.1.449.2.1.3.1.1.22.1
An RS366 Statistics Table entry. Each entry contains the statistics for a single RS366 port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPSTRS366PortEntry  

cdx6500RS366StatPortNumber 1.3.6.1.4.1.449.2.1.3.1.1.22.1.1
Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..52  

cdx6500RS366StatPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.22.1.2
Enabled or Disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500RS366StatPortState 1.3.6.1.4.1.449.2.1.3.1.1.22.1.3
Port State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500RS366StatDataNum 1.3.6.1.4.1.449.2.1.3.1.1.22.1.4
Data Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500RS366StatTotalCalls 1.3.6.1.4.1.449.2.1.3.1.1.22.1.5
Number of calls made.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500RS366StatFailedCalls 1.3.6.1.4.1.449.2.1.3.1.1.22.1.6
Number of failed calls.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500RS366StatTotalTimeouts 1.3.6.1.4.1.449.2.1.3.1.1.22.1.7
Number of protocol time-outs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500RS366StatTotalIllegalDigits 1.3.6.1.4.1.449.2.1.3.1.1.22.1.8
Number of illegal digits received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500RS366StatPortConnected 1.3.6.1.4.1.449.2.1.3.1.1.22.1.9
Connected to Data Port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString