RFC1304-MIB

File: RFC1304-MIB.mib (38598 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212

Imported symbols

Counter TimeTicks IpAddress
transmission OBJECT-TYPE

Defined Types

SMDSAddress  
OCTET STRING Size(8)    

SipL3Entry  
SEQUENCE    
  sipL3Index INTEGER
  sipL3ReceivedIndividualDAs Counter
  sipL3ReceivedGAs Counter
  sipL3UnrecognizedIndividualDAs Counter
  sipL3UnrecognizedGAs Counter
  sipL3SentIndividualDAs Counter
  sipL3SentGAs Counter
  sipL3Errors Counter
  sipL3InvalidSMDSAddressTypes Counter
  sipL3VersionSupport INTEGER

SipL2Entry  
SEQUENCE    
  sipL2Index INTEGER
  sipL2ReceivedCounts Counter
  sipL2SentCounts Counter
  sipL2HcsOrCRCErrors Counter
  sipL2PayloadLengthErrors Counter
  sipL2SequenceNumberErrors Counter
  sipL2MidCurrentlyActiveErrors Counter
  sipL2BomOrSSMsMIDErrors Counter
  sipL2EomsMIDErrors Counter

SipDS1PLCPEntry  
SEQUENCE    
  sipDS1PLCPIndex INTEGER
  sipDS1PLCPSEFSs Counter
  sipDS1PLCPAlarmState INTEGER
  sipDS1PLCPUASs Counter

SipDS3PLCPEntry  
SEQUENCE    
  sipDS3PLCPIndex INTEGER
  sipDS3PLCPSEFSs Counter
  sipDS3PLCPAlarmState INTEGER
  sipDS3PLCPUASs Counter

IpOverSMDSEntry  
SEQUENCE    
  ipOverSMDSIndex INTEGER
  ipOverSMDSAddress IpAddress
  ipOverSMDSHA SMDSAddress
  ipOverSMDSLISGA SMDSAddress
  ipOverSMDSARPReq SMDSAddress

SipL3PDUErrorEntry  
SEQUENCE    
  sipL3PDUErrorIndex INTEGER
  sipL3PDUErrorType INTEGER
  sipL3PDUErrorSA SMDSAddress
  sipL3PDUErrorDA SMDSAddress
  sipL3PDUErrorTimeStamp TimeTicks

Defined Values

sip 1.3.6.1.2.1.10.31
OBJECT IDENTIFIER    

sipL3Table 1.3.6.1.2.1.10.31.1
This table contains SIP L3 parameters and state variables, one entry per SIP port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SipL3Entry

sipL3Entry 1.3.6.1.2.1.10.31.1.1
This list contains SIP L3 parameters and state variables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SipL3Entry  

sipL3Index 1.3.6.1.2.1.10.31.1.1.1
The value of this object identifies the SIP port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in RFC 1156 and RFC 1213, for the same interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

sipL3ReceivedIndividualDAs 1.3.6.1.2.1.10.31.1.1.2
The total number of individually addressed SIP Level 3 PDUs received from the remote system across the SNI. The total includes only unerrored L3PDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL3ReceivedGAs 1.3.6.1.2.1.10.31.1.1.3
The total number of group addressed SIP Level 3 PDUs received from the remote system across the SNI. The total includes only unerrored L3PDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL3UnrecognizedIndividualDAs 1.3.6.1.2.1.10.31.1.1.4
The number of SIP Level 3 PDUs received from the remote system with invalid or unknown individual destination addresses (Destination Address Screening violations are not included). See SMDS Subscription MIB module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL3UnrecognizedGAs 1.3.6.1.2.1.10.31.1.1.5
The number of SIP Level 3 PDUs received from the remote system with invalid or unknown group addresses. (Destination Address Screening violations are not included). See SMDS Subscription MIB module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL3SentIndividualDAs 1.3.6.1.2.1.10.31.1.1.6
The number of individually addressed SIP Level 3 PDUs that have been sent by this system across the SNI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL3SentGAs 1.3.6.1.2.1.10.31.1.1.7
The number of group addressed SIP L3PDUs that have been sent by this system across the SNI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL3Errors 1.3.6.1.2.1.10.31.1.1.8
The total number of SIP Level 3 PDUs received from the remote system that were discovered to have errors (including protocol processing and bit errors but excluding addressing-related errors) and were discarded. Includes both group addressed L3PDUs and L3PDUs containing an individual destination address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL3InvalidSMDSAddressTypes 1.3.6.1.2.1.10.31.1.1.9
The number of SIP Level 3 PDUs received from the remote system that had the Source or Destination Address_Type subfields, (the four most significant bits of the 64 bit address field), not equal to the value 1100 or 1110. Also, an error is considered to have occurred if the Address_Type field for a Source Address, the four most significant bits of the 64 bits, is equal to 1110 (a group address).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL3VersionSupport 1.3.6.1.2.1.10.31.1.1.10
A value which indicates the version(s) of SIP that this interface supports. The value is a sum. This sum initially takes the value zero. For each version, V, that this interface supports, 2 raised to (V - 1) is added to the sum. For example, a port supporting versions 1 and 2 would have a value of (2^(1-1)+2^(2-1))=3. The sipL3VersionSupport is effectively a bit mask with Version 1 equal to the least significant bit (LSB).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

sipL2Table 1.3.6.1.2.1.10.31.2
This table contains SIP L2PDU parameters and state variables, one entry per SIP port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SipL2Entry

sipL2Entry 1.3.6.1.2.1.10.31.2.1
This list contains SIP L2 parameters and state variables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SipL2Entry  

sipL2Index 1.3.6.1.2.1.10.31.2.1.1
The value of this object identifies the SIP port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in RFC 1156 and RFC 1213, for the same interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

sipL2ReceivedCounts 1.3.6.1.2.1.10.31.2.1.2
The number of SIP Level 2 PDUs received from the remote system across the SNI. The total includes only unerrored L2PDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL2SentCounts 1.3.6.1.2.1.10.31.2.1.3
The number of SIP Level 2 PDUs that have been sent by this system across the SNI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL2HcsOrCRCErrors 1.3.6.1.2.1.10.31.2.1.4
The number of received SIP Level 2 PDUs that were discovered to have either a Header Check Sequence error or a Payload CRC violation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL2PayloadLengthErrors 1.3.6.1.2.1.10.31.2.1.5
The number of received SIP Level 2 PDUs that had Payload Length errors that fall in the following specifications: - SSM L2_PDU payload length field value less - than 28 octets or greater than 44 octets, - BOM or COM L2_PDU payload length field not - equal to 44 octets, - EOM L2_PDU payload length field value less - than 4 octets or greater than 44 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL2SequenceNumberErrors 1.3.6.1.2.1.10.31.2.1.6
The number of received SIP Level 2 PDUs that had a sequence number within the L2PDU not equal to the expected sequence number of the SMDS SS receive process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL2MidCurrentlyActiveErrors 1.3.6.1.2.1.10.31.2.1.7
The number of received SIP Level 2 PDUs that are BOMs for which an active receive process is already started.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL2BomOrSSMsMIDErrors 1.3.6.1.2.1.10.31.2.1.8
The number of received SIP Level 2 PDUs that are SSMs with a MID not equal to zero or are BOMs with MIDs equal to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipL2EomsMIDErrors 1.3.6.1.2.1.10.31.2.1.9
The number of received SIP Level 2 PDUs that are EOMs for which there is no active receive process for the MID (i.e., the receipt of an EOM which does not correspond to a BOM) OR the EOM has a MID equal to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipPLCP 1.3.6.1.2.1.10.31.3
OBJECT IDENTIFIER    

sipDS1PLCPTable 1.3.6.1.2.1.10.31.3.1
This table contains SIP DS1 PLCP parameters and state variables, one entry per SIP port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SipDS1PLCPEntry

sipDS1PLCPEntry 1.3.6.1.2.1.10.31.3.1.1
This list contains SIP DS1 PLCP parameters and state variables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SipDS1PLCPEntry  

sipDS1PLCPIndex 1.3.6.1.2.1.10.31.3.1.1.1
The value of this object identifies the SIP port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in RFC 1156 and RFC 1213, for the same interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

sipDS1PLCPSEFSs 1.3.6.1.2.1.10.31.3.1.1.2
A DS1 Severely Errored Framing Second (SEFS) is a count of one-second intervals containing one or more SEF events. A Severely Errored Framing (SEF) event is declared when an error in the A1 octet and an error in the A2 octet of a framing octet pair (i.e., errors in both framing octets), or two consecutive invalid and/or nonsequential Path Overhead Identifier octets are detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipDS1PLCPAlarmState 1.3.6.1.2.1.10.31.3.1.1.3
This variable indicates if there is an alarm present for the DS1 PLCP. The value receivedFarEndAlarm means that the DS1 PLCP has received an incoming Yellow Signal, the value incomingLOF means that the DS1 PLCP has declared a loss of frame (LOF) failure condition, and the value noAlarm means that there are no alarms present. See TR-TSV-000773 for a description of alarm states.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), receivedFarEndAlarm(2), incomingLOF(3)  

sipDS1PLCPUASs 1.3.6.1.2.1.10.31.3.1.1.4
The counter associated with the number of Unavailable Seconds, as defined by TR-TSV-000773, encountered by the PLCP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipDS3PLCPTable 1.3.6.1.2.1.10.31.3.2
This table contains SIP DS3 PLCP parameters and state variables, one entry per SIP port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SipDS3PLCPEntry

sipDS3PLCPEntry 1.3.6.1.2.1.10.31.3.2.1
This list contains SIP DS3 PLCP parameters and state variables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SipDS3PLCPEntry  

sipDS3PLCPIndex 1.3.6.1.2.1.10.31.3.2.1.1
The value of this object identifies the SIP port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in RFC 1156 and RFC 1213, for the same interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

sipDS3PLCPSEFSs 1.3.6.1.2.1.10.31.3.2.1.2
A DS3 Severely Errored Framing Second (SEFS) is a count of one-second intervals containing one or more SEF events. A Severely Errored Framing (SEF) event is declared when an error in the A1 octet and an error in the A2 octet of a framing octet pair (i.e., errors in both framing octets), or two consecutive invalid and/or nonsequential Path Overhead Identifier octets are detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sipDS3PLCPAlarmState 1.3.6.1.2.1.10.31.3.2.1.3
This variable indicates if there is an alarm present for the DS3 PLCP. The value receivedFarEndAlarm means that the DS3 PLCP has received an incoming Yellow Signal, the value incomingLOF means that the DS3 PLCP has declared a loss of frame (LOF) failure condition, and the value noAlarm means that there are no alarms present. See TR-TSV-000773 for a description of alarm states.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), receivedFarEndAlarm(2), incomingLOF(3)  

sipDS3PLCPUASs 1.3.6.1.2.1.10.31.3.2.1.4
The counter associated with the number of Unavailable Seconds, as defined by TR-TSV-000773, encountered by the PLCP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

smdsApplications 1.3.6.1.2.1.10.31.4
OBJECT IDENTIFIER    

ipOverSMDS 1.3.6.1.2.1.10.31.4.1
OBJECT IDENTIFIER    

ipOverSMDSTable 1.3.6.1.2.1.10.31.4.1.1
The table of addressing information relevant to this entity's IP addresses.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IpOverSMDSEntry

ipOverSMDSEntry 1.3.6.1.2.1.10.31.4.1.1.1
The addressing information for one of this entity's IP addresses.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IpOverSMDSEntry  

ipOverSMDSIndex 1.3.6.1.2.1.10.31.4.1.1.1.1
The value of this object identifies the SIP port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in RFC 1156 and RFC 1213, for the same interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ipOverSMDSAddress 1.3.6.1.2.1.10.31.4.1.1.1.2
The IP address to which this entry's addressing information pertains.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ipOverSMDSHA 1.3.6.1.2.1.10.31.4.1.1.1.3
The SMDS Individual address of the IP station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SMDSAddress  

ipOverSMDSLISGA 1.3.6.1.2.1.10.31.4.1.1.1.4
The SMDS Group Address that has been configured to identify the SMDS Subscriber-Network Interfaces (SNIs) of all members of the Logical IP Subnetwork (LIS) connected to the network supporting SMDS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SMDSAddress  

ipOverSMDSARPReq 1.3.6.1.2.1.10.31.4.1.1.1.5
The SMDS address (individual or group) to which ARP Requests are to be sent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SMDSAddress  

smdsCarrierSelection 1.3.6.1.2.1.10.31.5
OBJECT IDENTIFIER    

sipErrorLog 1.3.6.1.2.1.10.31.6
OBJECT IDENTIFIER    

sipL3PDUErrorTable 1.3.6.1.2.1.10.31.6.1
A table that contains the latest occurrence of the following syntactical SIP L3PDU errors: - Destination Address Field Format Error, The following pertains to the 60 least significant bits of the 64 bit address field. The 60 bits contained in the address subfield can be used to represent addresses up to 15 decimal digits. Each decimal digit shall be encoded into four bits using Binary Coded Decimal (BCD), with the most significant digit occurring left-most. If not all 15 digits are required, then the remainder of this field shall be padded on the right with bits set to one. An error is considered to have occurred: a). if the first four bits of the address subfield are not BCD, OR b). if the first four bits of the address subfield are populated with the country code value 0001, AND the 40 bits which follow are not Binary Coded Decimal (BCD) encoded values of the 10 digit addresses, OR the remaining 16 least significant bits are not populated with 1's, OR c). if the address subfield is not correct according to another numbering plan which is dependent upon the carrier assigning the numbers and offering SMDS. - Source Address Field Format Error, The description of this parameter is the same as the description of the Destination Address Field Format Error. - Invalid BAsize Field Value, An error is considered to have occurred when the BAsize field of an SIP L3PDU contains a value less that 32, greater than 9220 octets without the CRC32 field present, greater than 9224 octets with the CRC32 field present, or not equal to a multiple of 4 octets, - Invalid Header Extension Length Field Value, An error is considered to have occurred when the Header Extension Length field value is not equal 3. - Invalid Header Extension - Element Length, An error is considered to have occurred when the Header Extension - Element Length is greater than 12. - Invalid Header Extension - Version Element Position, Length, or Value, An error is considered to have occurred when a Version element with Length=3, Type=0, and Value=1 does not appear first within the Header Extension, or an element Type=0 appears somewhere other than within the first three octets in the Header Extension. - Invalid Header Extension - Carrier Selection Element Position, Length, Value or Format, An error is considered to have occurred when a Carrier Selection element does not appear second within the Header Extension, if the Element Type does not equal 1, the Element Length does not equal 4, 6, or 8, the Element Value field is not four BCD encoded decimal digits used in specifying the Carrier Identification Code (CIC), or the identified CIC code is invalid. - Header Extension PAD Error An error is considered to have occurred when the Header Extension PAD is 9 octets in length, or if the Header Extension PAD is greater than zero octets in length and the Header Extension PAD does not follow all Header Extension elements or does not begin with at least one octet of all zeros. - BEtag Mismatch Error, An error is considered to have occurred when the Beginning-End Tags in the SIP L3PDU header and trailer are not equal. - BAsize Field not equal to Length Field Error, An error is considered to have occurred when the value of the BAsize Field does not equal the value of the Length Field. - Incorrect Length Error, and An error is considered to have occurred when the the Length field value is not equal to the portion of the SIP L3PDU which extends from the Destination Address field up to and including the CRC32 field (if present) or up to and including the PAD field (if the CRC32 field is not present). As an optional check, an error is considered to have occurred when the length of a partially received SIP L3PDU exceeds the BAsize value. - MRI Timeout Error. An error is considered to have occurred when the elapsed time between receipt of BOM and corresponding EOM exceeds the value of the MRI (Message Receive Interval) for a particular transport signal format. An entry is indexed by interface number and error type, and contains Source Address, Destination Address and a timestamp. All these errors are counted in the sipL3Errors counter. When sipL3PDUErrorTimeStamp is equal to zero, the SipL3PDUErrorEntry does not contain any valid information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SipL3PDUErrorEntry

sipL3PDUErrorEntry 1.3.6.1.2.1.10.31.6.1.1
An entry in the service disagreement table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SipL3PDUErrorEntry  

sipL3PDUErrorIndex 1.3.6.1.2.1.10.31.6.1.1.1
The value of this object identifies the SIP port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in RFC 1156 and RFC 1213, for the same interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

sipL3PDUErrorType 1.3.6.1.2.1.10.31.6.1.1.2
The type of error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER erroredDAFieldFormat(1), erroredSAFieldFormat(2), invalidBAsizeFieldValue(3), invalidHdrExtLength(4), invalidHdrExtElementLength(5), invalidHdrExtVersionElementPositionLenthOrValue(6), invalidHdrExtCarSelectElementPositionLenghtValueOrFormat(7), hePADError(8), beTagMismatch(9), baSizeFieldNotEqualToLengthField(10), incorrectLength(11), mriTimeout(12)  

sipL3PDUErrorSA 1.3.6.1.2.1.10.31.6.1.1.3
A rejected SMDS source address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SMDSAddress  

sipL3PDUErrorDA 1.3.6.1.2.1.10.31.6.1.1.4
A rejected SMDS destination address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SMDSAddress  

sipL3PDUErrorTimeStamp 1.3.6.1.2.1.10.31.6.1.1.5
The timestamp for the service disagreement. The timestamp contains the value of sysUpTime at the latest occurrence of this type of service disagreement. See textual description under sipL3PDUErrorTable for boundary conditions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks