REDLINE-E1T1-MIB

File: REDLINE-E1T1-MIB.mib (15667 bytes)

Imported modules

RFC1155-SMI SNMPv2-TC RFC-1212
RFC-1215

Imported symbols

IpAddress Counter TimeTicks
enterprises RowStatus OBJECT-TYPE
TRAP-TYPE

Defined Types

E1T1SerialEntry  
SEQUENCE    
  e1t1SerialID INTEGER
  e1t1SerialCoding INTEGER
  e1t1SerialFraming INTEGER
  e1t1SerialLBO INTEGER

E1T1GroupEntry  
SEQUENCE    
  e1t1GroupID INTEGER
  e1t1GroupTsBegin INTEGER
  e1t1GroupTsNum INTEGER
  e1t1GroupDestGroup INTEGER
  e1t1GroupDestIp IpAddress
  e1t1GroupJitterBuffer INTEGER
  e1t1GroupPacketLength INTEGER
  e1t1GroupRowStatus RowStatus

E1T1StatsEntry  
SEQUENCE    
  e1t1SerialStatsID INTEGER
  e1t1TdmsLOS INTEGER
  e1t1TdmsLFA INTEGER
  e1t1TdmsLOMF INTEGER
  e1t1TdmsRAI INTEGER
  e1t1TdmsAIS INTEGER
  e1t1TdmsES INTEGER
  e1t1TdmsFEC INTEGER
  e1t1TdmsCVC INTEGER

Defined Values

redline 1.3.6.1.4.1.10728
OBJECT IDENTIFIER    

redlineProducts 1.3.6.1.4.1.10728.1
OBJECT IDENTIFIER    

redlineMgmt 1.3.6.1.4.1.10728.2
OBJECT IDENTIFIER    

redlineE1T1 1.3.6.1.4.1.10728.2.52
OBJECT IDENTIFIER    

e1t1General 1.3.6.1.4.1.10728.2.52.1
OBJECT IDENTIFIER    

e1t1Stats 1.3.6.1.4.1.10728.2.52.5
OBJECT IDENTIFIER    

e1t1Commands 1.3.6.1.4.1.10728.2.52.6
OBJECT IDENTIFIER    

e1t1VlanIdData 1.3.6.1.4.1.10728.2.52.1.1
VLAN ID for data on E1/T1 module
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

e1t1VlanIdVoice 1.3.6.1.4.1.10728.2.52.1.2
VLAN ID for voice on E1/T1 module
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

e1t1Clock 1.3.6.1.4.1.10728.2.52.1.3
Clocking information on the E1/T1 module
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2  

e1t1SyncOn 1.3.6.1.4.1.10728.2.52.1.4
The number of serial interface to be used as clocking reference. For AN-50 the number of serial interfaces is 4
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

e1t1IdleCode 1.3.6.1.4.1.10728.2.52.1.5
Idle Code for unused timeslots on the E1/T1 module
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

e1t1Hostname 1.3.6.1.4.1.10728.2.52.1.6
E1/T1 host name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

e1t1IpAddress 1.3.6.1.4.1.10728.2.52.1.7
E1/T1 IP address
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

e1t1IpMask 1.3.6.1.4.1.10728.2.52.1.8
E1/T1 IP mask
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

e1t1IpGateway 1.3.6.1.4.1.10728.2.52.1.9
E1/T1 gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

e1t1OptionKey 1.3.6.1.4.1.10728.2.52.1.10
E1/T1 Option Key.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1Line 1.3.6.1.4.1.10728.2.52.1.11
The type of the line (T1/E1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

e1t1SoftwareVersion 1.3.6.1.4.1.10728.2.52.1.12
E1/T1 module Software Version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

e1t1SaveConfig 1.3.6.1.4.1.10728.2.52.6.1
Save the running configuration in flash.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER donothing(1), saveConfig(2)  

e1t1ActivateConfig 1.3.6.1.4.1.10728.2.52.6.2
Activate temporary configuration in running configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER donothing(1), activeConfig(2)  

e1t1ResetBoard 1.3.6.1.4.1.10728.2.52.6.3
Reset the E1/T1 module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER donothing(1), reset(2)  

e1t1ResetStats 1.3.6.1.4.1.10728.2.52.6.4
Reset Statistics for the E1/T1 module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

e1t1ReStartConfig 1.3.6.1.4.1.10728.2.52.6.5
ReStart the configuration operation for the E1/T1 module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER donothing(1), reset(2)  

e1t1EthRate 1.3.6.1.4.1.10728.2.52.5.1
Ethernet rate for the E1/T1 module. 0 = 10 Mbps 1 = 100 Mbps
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthMode 1.3.6.1.4.1.10728.2.52.5.2
E1/T1 module mode. 0 - half duplex 1 - full duplex
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthState 1.3.6.1.4.1.10728.2.52.5.3
E1/T1 module state. 0 - not connected 1 - connected
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthMAC 1.3.6.1.4.1.10728.2.52.5.4
E1/T1 module MAC Address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthFROK 1.3.6.1.4.1.10728.2.52.5.5
E1/T1 module frames received OK (FROK).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthBROK 1.3.6.1.4.1.10728.2.52.5.6
E1/T1 module bytes received OK (BROK).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthAERR 1.3.6.1.4.1.10728.2.52.5.7
E1/T1 module alignment errors (AERR).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthCERR 1.3.6.1.4.1.10728.2.52.5.8
E1/T1 module CRC errors (CERR).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthFTOK 1.3.6.1.4.1.10728.2.52.5.9
E1/T1 module frames transmitted OK (FTOK).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthBTOK 1.3.6.1.4.1.10728.2.52.5.10
E1/T1 module bytes transmitted OK (BTOK).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthSCOL 1.3.6.1.4.1.10728.2.52.5.11
E1/T1 module single collisions (SCOL).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthMCOL 1.3.6.1.4.1.10728.2.52.5.12
E1/T1 module multiple collisions (MCOL).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthTDEF 1.3.6.1.4.1.10728.2.52.5.13
E1/T1 module transmissions deferred (TDEF).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1EthLCOL 1.3.6.1.4.1.10728.2.52.5.14
E1/T1 module late collisions (LCOL).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1FanStatus 1.3.6.1.4.1.10728.2.52.5.15
T1E1 Fan Status (off/on).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

e1t1LastSaveErr 1.3.6.1.4.1.10728.2.52.5.16
The Error code from the last TDM SAVE Command.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1SerialTable 1.3.6.1.4.1.10728.2.52.2
Table T1 / E1 Channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    E1T1SerialEntry

e1t1SerialEntry 1.3.6.1.4.1.10728.2.52.2.1
A unique set of link parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  E1T1SerialEntry  

e1t1SerialID 1.3.6.1.4.1.10728.2.52.2.1.1
Serial ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

e1t1SerialCoding 1.3.6.1.4.1.10728.2.52.2.1.2
Serial Coding.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..128  

e1t1SerialFraming 1.3.6.1.4.1.10728.2.52.2.1.3
Serial Framing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..128  

e1t1SerialLBO 1.3.6.1.4.1.10728.2.52.2.1.4
Serial LBO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..128  

e1t1GroupTable 1.3.6.1.4.1.10728.2.52.3
Table E1 Groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    E1T1GroupEntry

e1t1GroupEntry 1.3.6.1.4.1.10728.2.52.3.1
A unique set of link parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  E1T1GroupEntry  

e1t1GroupID 1.3.6.1.4.1.10728.2.52.3.1.1
Group ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

e1t1GroupTsBegin 1.3.6.1.4.1.10728.2.52.3.1.2
Group Ts Begin.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

e1t1GroupTsNum 1.3.6.1.4.1.10728.2.52.3.1.3
Group Ts Num.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

e1t1GroupDestGroup 1.3.6.1.4.1.10728.2.52.3.1.4
Group Destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

e1t1GroupDestIp 1.3.6.1.4.1.10728.2.52.3.1.5
Group Destination Ip Address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

e1t1GroupJitterBuffer 1.3.6.1.4.1.10728.2.52.3.1.6
Group Jitter Buffer in ms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..300  

e1t1GroupPacketLength 1.3.6.1.4.1.10728.2.52.3.1.7
Group Jitter Buffer in bytes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 64..1024  

e1t1GroupRowStatus 1.3.6.1.4.1.10728.2.52.3.1.8
Status of the row.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

e1t1StatsTable 1.3.6.1.4.1.10728.2.52.4
Table of statistics for E1/T1 interfaces.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    E1T1StatsEntry

e1t1StatsEntry 1.3.6.1.4.1.10728.2.52.4.1
A unique set of statistics of link parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  E1T1StatsEntry  

e1t1SerialStatsID 1.3.6.1.4.1.10728.2.52.4.1.1
Serial Interface Statistics ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

e1t1TdmsLOS 1.3.6.1.4.1.10728.2.52.4.1.2
E1/T1 module loss of signal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1TdmsLFA 1.3.6.1.4.1.10728.2.52.4.1.3
E1/T1 module loss of framing alignment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1TdmsLOMF 1.3.6.1.4.1.10728.2.52.4.1.4
E1/T1 module loss of multiframming.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1TdmsRAI 1.3.6.1.4.1.10728.2.52.4.1.5
E1/T1 module remote alarm indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1TdmsAIS 1.3.6.1.4.1.10728.2.52.4.1.6
E1/T1 module alarm indication signal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1TdmsES 1.3.6.1.4.1.10728.2.52.4.1.7
E1/T1 module errored seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1TdmsFEC 1.3.6.1.4.1.10728.2.52.4.1.8
E1/T1 module framing error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

e1t1TdmsCVC 1.3.6.1.4.1.10728.2.52.4.1.9
E1/T1 module code violation counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER