READYNAS-MIB

File: READYNAS-MIB.mib (18206 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1155-SMI
RFC1213-MIB

Imported symbols

OBJECT-TYPE TRAP-TYPE enterprises
DisplayString

Defined Types

DiskEntry  
SEQUENCE    
  diskNumber INTEGER
  diskChannel INTEGER
  diskModel DisplayString
  diskState DisplayString
  diskTemperature INTEGER

FanEntry  
SEQUENCE    
  fanNumber INTEGER
  fanRPM INTEGER
  fanType DisplayString

TemperatureEntry  
SEQUENCE    
  temperatureNumber INTEGER
  temperatureValue INTEGER
  temperatureStatus DisplayString

VolumeEntry  
SEQUENCE    
  volumeNumber INTEGER
  volumeName DisplayString
  volumeRAIDLevel DisplayString
  volumeStatus DisplayString
  volumeSize INTEGER
  volumeFreeSpace INTEGER

PSUEntry  
SEQUENCE    
  psuNumber INTEGER
  psuStatus DisplayString
  psuDesc DisplayString

Defined Values

netgear 1.3.6.1.4.1.4526
OBJECT IDENTIFIER    

productID 1.3.6.1.4.1.4526.100
OBJECT IDENTIFIER    

readyNAS 1.3.6.1.4.1.4526.100.12
OBJECT IDENTIFIER    

nasManager 1.3.6.1.4.1.4526.18
OBJECT IDENTIFIER    

nasMgrSoftwareVersion 1.3.6.1.4.1.4526.18.1
Version information for the ReadyNAS NAS Manager software.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

diskTable 1.3.6.1.4.1.4526.18.3
A table of physical disks attached to the NAS device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DiskEntry

diskEntry 1.3.6.1.4.1.4526.18.3.1
An entry in the physical disk table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DiskEntry  

diskNumber 1.3.6.1.4.1.4526.18.3.1.1
Instance number of the disk entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

diskChannel 1.3.6.1.4.1.4526.18.3.1.2
Channel number that the disk is connected to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

diskModel 1.3.6.1.4.1.4526.18.3.1.3
The disk drive's model name.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

diskState 1.3.6.1.4.1.4526.18.3.1.4
The current state of the Disk. Possible states: 0: Online 1: Offline
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

diskTemperature 1.3.6.1.4.1.4526.18.3.1.5
temperature of this disk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fanTable 1.3.6.1.4.1.4526.18.4
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FanEntry

fanEntry 1.3.6.1.4.1.4526.18.4.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  FanEntry  

fanNumber 1.3.6.1.4.1.4526.18.4.1.1
Instance number of this fan entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10000000  

fanRPM 1.3.6.1.4.1.4526.18.4.1.2
The current speed of the fan.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fanType 1.3.6.1.4.1.4526.18.4.1.3
What fan is used for: SYS: for system board CPU: for CPU CAS: for system case
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

temperatureTable 1.3.6.1.4.1.4526.18.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TemperatureEntry

temperatureEntry 1.3.6.1.4.1.4526.18.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TemperatureEntry  

temperatureNumber 1.3.6.1.4.1.4526.18.5.1.1
Instance number of this temperature probe entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

temperatureValue 1.3.6.1.4.1.4526.18.5.1.2
The current temperature of this probe.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

temperatureStatus 1.3.6.1.4.1.4526.18.5.1.3
The current temperature status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

volumeTable 1.3.6.1.4.1.4526.18.7
A table of active volumes on the NAS device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VolumeEntry

volumeEntry 1.3.6.1.4.1.4526.18.7.1
An entry in the volume table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VolumeEntry  

volumeNumber 1.3.6.1.4.1.4526.18.7.1.1
Instance number of the volume entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

volumeName 1.3.6.1.4.1.4526.18.7.1.2
The name of the volume.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

volumeRAIDLevel 1.3.6.1.4.1.4526.18.7.1.3
The RAID level of the volume.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

volumeStatus 1.3.6.1.4.1.4526.18.7.1.4
The severity of the volume. Possible values: 1: Clean 2: Error 16: Initialized (Normal)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

volumeSize 1.3.6.1.4.1.4526.18.7.1.5
The size of the volume in megabytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

volumeFreeSpace 1.3.6.1.4.1.4526.18.7.1.6
Free space on the volume in megabytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

psuTable 1.3.6.1.4.1.4526.18.8
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PSUEntry

psuEntry 1.3.6.1.4.1.4526.18.8.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PSUEntry  

psuNumber 1.3.6.1.4.1.4526.18.8.1.1
Instance number of this power supply unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

psuDesc 1.3.6.1.4.1.4526.18.8.1.2
The description of this PSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

psuStatus 1.3.6.1.4.1.4526.18.8.1.3
The current PSU status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

aryMgrEvts 1.3.6.1.4.1.4526.18.200
OBJECT IDENTIFIER    

controllerNameEv 1.3.6.1.4.1.4526.18.200.201
Controller Name for which trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

channelNumberEv 1.3.6.1.4.1.4526.18.200.202
Channel Number for which trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

targetIDEv 1.3.6.1.4.1.4526.18.200.203
SCSI ID of the device for which trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

virtualDiskNameEv 1.3.6.1.4.1.4526.18.200.204
Virtual Disk for which trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

arrayDiskNameEv 1.3.6.1.4.1.4526.18.200.205
Array Disk for which trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

oldVDConfigEv 1.3.6.1.4.1.4526.18.200.206
Current Virtual Disk configuration for which trap is generated
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..128)  

newVDConfigEv 1.3.6.1.4.1.4526.18.200.207
New Virtual Disk configuration for which trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..128)  

enclosureNumberEv 1.3.6.1.4.1.4526.18.200.208
Enclosure Number for which trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unitNumberEv 1.3.6.1.4.1.4526.18.200.209
Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

enclosureNameEv 1.3.6.1.4.1.4526.18.200.210
Enclosure Name for which trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitNameEv 1.3.6.1.4.1.4526.18.200.211
Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

timeEv 1.3.6.1.4.1.4526.18.200.212
Amount of time specified in the trap message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

volumeNameEv 1.3.6.1.4.1.4526.18.200.213
Volume Drive Letter for which trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fanFailureMesg 1.3.6.1.4.1.4526.18.400
Failure message for Fan
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tempFailureMesg 1.3.6.1.4.1.4526.18.401
Failure message for system temperature
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerFailureMesg 1.3.6.1.4.1.4526.18.402
Failure message for system power
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

raidMesg 1.3.6.1.4.1.4526.18.403
RAID hotplug event message
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

snapshotMesg 1.3.6.1.4.1.4526.18.404
Snapshot messages
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

upsMesg 1.3.6.1.4.1.4526.18.405
UPS status message
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sataMesg 1.3.6.1.4.1.4526.18.406
SATA hotplug event messages
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

volumeMesg 1.3.6.1.4.1.4526.18.407
Disk usage warning
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

diskTempWarningMesg 1.3.6.1.4.1.4526.18.408
Disk temperature warning messages
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

backupMesg 1.3.6.1.4.1.4526.18.409
Backup job status messages
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

smartMesg 1.3.6.1.4.1.4526.18.410
Disk SMART messages
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

psuMesg 1.3.6.1.4.1.4526.18.411
PSU status messages
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

nasTraps 1.3.6.1.4.1.4526.18.300
OBJECT IDENTIFIER    

fanFailure 10
Fan failure, fan speed is %s.
TRAP-TYPE    

tempFailure 20
Temperature sensor reports out of normal range.
TRAP-TYPE    

powerVoltage 30
System power is out of spec, please check system status!
TRAP-TYPE    

raidEventNotice 40
RAID event detected!
TRAP-TYPE    

snapshotEventNotice 50
Snapshot event detected!
TRAP-TYPE    

hotplugDiskNotice 60
Hotplug disk event detected!
TRAP-TYPE    

upsEventNotice 70
UPS status.
TRAP-TYPE    

volumeNotice 80
Volume is approaching capacity.
TRAP-TYPE    

diskTempWarning 90
Disk temperature warning.
TRAP-TYPE    

backupNotice 100
Backup job status.
TRAP-TYPE    

diskSmartWarning 110
Disk SMART warning.
TRAP-TYPE    

psuWarning 120
Power supply unit warning.
TRAP-TYPE