RDN-EVT-NOTIFICATIONS
File:
RDN-EVT-NOTIFICATIONS.mib (34501 bytes)
Imported modules
Imported symbols
Defined Values
rdnEvtNotifications |
1.3.6.1.4.1.4981.0 |
MIB module for EVT Notifications. The following notifications
are generated by EVTs. The Event Id for each event is represented
as the last sub identifier for each notification.
The DOCSIS Event Id(docsDevEvId) or last sub-identifier is
calculated by adding the Motorola Event Id Base + Vendor Specific
Event Base + + the EVT subsystem base + index (1-255).
Example of DRM.56 'Spare CMTS Active' event identifier is:
Vendor Event Id Base 0x80000000
Motorola Event Base + 0x13750000
DRM Evt subsystem Base + 0x 700
56 (in hex) + 0x 38
----------
0x93750738 hex
or 2473920312 decimal
The CLI command 'show evt' also displays the bases for the EVT
subsystems that are registered.
All EVT notifications contain the same set variable-bindings:
docsDevEvLevel - this event's severity level.
docsDevEvId - the DOSIS Event Id for this particular event,
and also the last sub identifier for this notification.
docsDevEvText - The DOCSIS Event Text for this event,
ASCII printable text that is displayed for this event.
docsIfDocsisBaseCapability - The current DOCSIS capabilities of
this agent.
ifPhysAddress - Not used at this time.
This MIB just list a few of the notifications generated by EVT,
specifically all EVTs notification with a severity level of
critical or higher.
Copyright (C) 2003, 2008 by Motorola, Inc.
All rights reserved. |
MODULE-IDENTITY |
|
|
|
rdnEvtMacrtrGetQIdFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error.
The MACRTR task was unable to get the DOCSIS Redundancy Agent(DRA)
task main message queue id. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtMacrtrUnknownCase |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The MACRTR task was received
an unexpected case, which is not handled. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtMacrtrMsgQReceiveFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The MACRTR task caught an error
when it was receiving a message. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtMacrtrRdbDefineTableFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The MACRTR task was unable
to register a table with the Redundancy Runtime Record
Database(RDB) for CMTS Redundancy. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtMacrtrRxUnexpectedMsgType |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The MACRTR task received an
unexpected message type. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtMacrtrRegTaskMonFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The MACRTR task was unable to
register with the task monitor. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtMacrtrInvalidFuncParam |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The MACRTR task detected an
invalid function parameter. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtMacrtrUnknownCmId |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. During a CMTS Switchover,
the MACRTR task was unable to determine the cable modem Id when
loading the Cable Modem runtime record. This notification is only
generated on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtBpiLoadAuthRunRecFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Baseline Privacy
Interface(BPI) task was unable to load the Authorization Key
runtime record during a CMTS Switchover. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtBpiLoadTekRunRecFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Baseline Privacy
Interface(BPI) task was unable to load the TEK runtime
record during a CMTS Switchover. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtBpiLoadCmCertificateFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Baseline Privacy
Interface(BPI) task was unable to load the Cable Modem
Certificate during a CMTS Switchover. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDraTaskSpawnFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. Unable to create the
DOCSIS Redundancy Agent(DRA) task. This notification is only
generated on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDraMsgQCreateFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. Unable to create the DRA task's
message queue. This notification is only generated on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDraMsgQReceiveFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. DRA task's caught an error
when it was receiving a message. This notification is only
generated on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDraRegTaskMonFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. DRA task was unable to register
with the task monitor. This notification is only
generated on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDraCreateRdbFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. DRA task was
unable to create a Redundancy Runtime Database for CMTS Redundancy.
This notification is only generated on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDraRxUnexpectedMsgType |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. DRA task received an unexpected
message type. This notification is only generated on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDraRxUnexpectedMsgSubType |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. DRA task received an unexpected
message sub-type. This notification is only generated on the
BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDraTmrInitFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. DRA was unable to
create its timers. This notification is only generated
on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDraInvalidFuncParam |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The DRA task detected an
invalid function parameter. This notification is only generated
on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDraInvalidMsgParam |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The DRA task detected an
invalid message parameter. This notification is only generated
on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtRdbMsgQCheckFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal resource error. The is a major component
failure with on of RDB's message queues, that may lead to
system failures. Try correcting this problem by resetting this
CMTS. This notification is only generated on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtRdbCreateDatabaseFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal error. There is a major component
failure creating a database for CMTS redundancy, this could
lead to system failures. This notification is only generated
on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtRdbInitDatabaseFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal error. There is a major component
failure initializing a database for CMTS redundancy, this could
lead to system failures. This notification is only generated
on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtRdbSemCreateFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. RDB task was unable to create
a semaphore for mutual exclusion. This notification is only generated
on the BSR 64000. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtRdbUnknownTableFromPeer |
1.3.6.1.4.1.4981.0.0 |
Software versions may not be the same on the Primary and
the Spare. This may cause a loss of data on replications of
the redundancy databases and lead to serious problem on a
switchover. Upgrade the software so that the Primary and Spare
have matching software versions. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtRdbDefineTableNotEnoughMemory |
1.3.6.1.4.1.4981.0.0 |
Not Enough Memory to register a new table with RDB. This could
lead loss of data on replications of the redundancy databases and
lead to serious problem on a switchovers. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtRdbMsgBufAllocFailure |
1.3.6.1.4.1.4981.0.0 |
Not Enough Memory to create message buffers in RDB. This could
lead loss of data on replications of the redundancy databases and
lead to serious problem on a switchovers. Reset the card
reporting this problem. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtRdbMemPoolAllocFailure |
1.3.6.1.4.1.4981.0.0 |
Not Enough Memory to create storage for the runtime records.
This could lead to loss of data on replications of the
redundancy databases and lead to serious problems on a switchover. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtRdbMallocFailure |
1.3.6.1.4.1.4981.0.0 |
Memory allocation for internal RDB structure reported an error.
This card is most like running low on memory. Reset the card
reporting this problem. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDrmSpareCmtsActive |
1.3.6.1.4.1.4981.0.0 |
This is reported when a Spare CMTS becomes active
for a redundant primary CMTS in a BSR 64000 chassis. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDrmFailedAutoTakeover |
1.3.6.1.4.1.4981.0.0 |
This is reported when a Primary CMTS goes down, and
an auto-takeover fails to make Spare CMTS become the
active CMTS in a BSR 64000 chassis. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDrmFailedAutoGiveback |
1.3.6.1.4.1.4981.0.0 |
This is reported when a active Spare CMTS goes down, and
an auto-giveback fails to make Primary CMTS become the
active CMTS in a BSR 64000 chassis. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDrmSpareXmittersRcvrsMismatch |
1.3.6.1.4.1.4981.0.0 |
This is reported when Spare CMTS has fewer transmitters or
receivers than a Primary CMTS. The Spare CMTS must have at
least as many transmitters and receivers as each Primary CMTS
in order to have successful CMTS switchovers in a
BSR 64000 chassis. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDrmSpareDtxActive |
1.3.6.1.4.1.4981.0.0 |
This is reported when a Spare DTX becomes active
for a redundant primary DTX in a BSR 64000 chassis. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDrmFailedDtxAutoTakeover |
1.3.6.1.4.1.4981.0.0 |
This is reported when a Primary DTX goes down, and
an auto-takeover fails to make Spare DTX become the
active DTX in a BSR 64000 chassis. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDrmFailedDtxAutoGiveback |
1.3.6.1.4.1.4981.0.0 |
This is reported when a active Spare DTX goes down, and
an auto-giveback fails to make Primary DTX become the
active DTX in a BSR 64000 chassis. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDrmSpareDrxActive |
1.3.6.1.4.1.4981.0.0 |
This is reported when a Spare DRX becomes active
for a redundant primary DRX in a BSR 64000 chassis. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDrmFailedDrxAutoTakeover |
1.3.6.1.4.1.4981.0.0 |
This is reported when a Primary DRX goes down, and
an auto-takeover fails to make Spare DRX become the
active DRX in a BSR 64000 chassis. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDrmFailedDrxAutoGiveback |
1.3.6.1.4.1.4981.0.0 |
This is reported when a active Spare DRX goes down, and
an auto-giveback fails to make Primary DRX become the
active DRX in a BSR 64000 chassis. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtAccrtrRdbDefineTableFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Accrtr task was unable
to register a table with the Redundancy Runtime Record
Database(RDB) for CMTS Redundancy. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtAccrtrRdbNextFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Accrtr task was unable
retrieve the next runtime record from Redundancy Runtime Record
Database(RDB) for CMTS Redundancy. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtAccrtrNotFrozenLoad |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Accrtr task was not frozen
when trying to load the runtime records for a particular cable
modem during a CMTS Switchover. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtArdrtrRdbDefineTableFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was unable
to register a table with the Redundancy Runtime Record
Database(RDB) for CMTS Redundancy. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtArdrtrRdbNextFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was unable
retrieve the next runtime record from Redundancy Runtime Record
Database(RDB) for CMTS Redundancy. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtArdrtrNotFrozenLoad |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was not frozen
when trying to load the runtime records for a particular cable
modem during a CMTS Switchover. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtArdrtrLoadFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was unable to load
the runtime records do to an invalid cable modem Id during a
CMTS Switchover. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtMacmgrValidateCmError |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Macmgr task received
a 'Validate Cable Modem' message from BPI, which contained an
invalid cable modem index. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtMacmgrInvalidateCmError |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Macmgr task received
a 'Invalidate Cable Modem' message from BPI, which contained an
invalid cable modem index. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtMacmgrNullPtr |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Macmgr task called a
function with a null pointer. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDocsifCmtsCmIndexAddFreeListFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. Unable to add
the docsIfCmtsCmStatusIndex to a list of indexes available to use. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDocsifCmtsCmIndexDelFreeListFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. Unable to remove
the docsIfCmtsCmStatusIndex from a list of indexes available to use. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtDocsifCmtsCmIndexReloadFreeListFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. Unable to reload
the docsIfCmtsCmStatusIndex from a list of indexes available to use. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtUpcTaskSpawnFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. Unable to create the
Up Converter(UPC) task. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtUpcMsgQCreateFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. Unable to create the UPC task's
message queue. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtUpcMsgQReceiveFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. UPC task's caught an error
when it was receiving a message. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtUpcRegTaskMonFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. UPC task was unable to register
with the task monitor. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtUpcRxUnexpectedMsgType |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. UPC task received an unexpected
message type. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtUpcRxUnexpectedMsgSubType |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. UPC task received an unexpected
message sub-type. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtUpcSemCreateFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. UPC task was unable to create a
semaphore for mutual exclusion. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtSvcfloNullPtr |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The SVCFLO task called a
function will a null pointer. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtSvcfloWriteNextFlowTlvError |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The SVCFLO task
detected an error when trying to backup a Service Flow TLV for
CMTS Redundancy. This TLV is not replicated to the peer CMTS,
and could cause this modem to de-register on a CMTS switchover. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtSvcfloSidInsertFailure |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The SVCFLO task
was unable to store the cable modems Service Id (SID). |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtUbshaCollectionRspMallocError |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. Failed to allocate memory during
upstream channel sampling response. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
rdnEvtUbshaTaskSuspended |
1.3.6.1.4.1.4981.0.0 |
This is an internal software error. The Upstream Bandwidth
Scheduler(UBS) task suspended itself. Reset CMTS to clear the
error. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|