RC7586-MIB
File:
RC7586-MIB.mib (28672 bytes)
Imported modules
Imported symbols
Defined Types
ComponentRevision |
|
The hex value in the first octet - xx - represents the major revision no.
and the hex value in the second octet - yy - represents the minor revision no. |
TEXTUAL-CONVENTION |
|
|
|
|
DisplayString |
Size(2) |
|
FaultStatus7586 |
|
Describes all the possible faults in the system as a bit pattern. |
TEXTUAL-CONVENTION |
|
|
|
|
BITS |
dc1fault(0), dc2fault(1), buc1fault(2), buc2fault(3), lnb1fault(4), lnb2fault(5), txswfault(6), rxswfault(7), internalfault(8), ref10mhzfault(9) |
|
Defined Values
rc7586MIB |
1.3.6.1.4.1.23304.2.2 |
The Structure of Management Information for the
Codan enterprise.
Copyright(c) 2009 All rights reserved |
MODULE-IDENTITY |
|
|
|
buc1 |
1.3.6.1.4.1.23304.2.2.1 |
OBJECT IDENTIFIER |
|
|
|
buc2 |
1.3.6.1.4.1.23304.2.2.2 |
OBJECT IDENTIFIER |
|
|
|
ctrl |
1.3.6.1.4.1.23304.2.2.3 |
OBJECT IDENTIFIER |
|
|
|
settings |
1.3.6.1.4.1.23304.2.2.3.1 |
OBJECT IDENTIFIER |
|
|
|
status |
1.3.6.1.4.1.23304.2.2.3.2 |
OBJECT IDENTIFIER |
|
|
|
info |
1.3.6.1.4.1.23304.2.2.3.3 |
OBJECT IDENTIFIER |
|
|
|
operationalMode |
1.3.6.1.4.1.23304.2.2.3.1.1 |
Sets 7586 operational mode - Auto, Manual Stream1, Stream2. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2 |
|
onlineStream |
1.3.6.1.4.1.23304.2.2.3.1.2 |
Sets the online stream. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..2 |
|
waveguideSwitch |
1.3.6.1.4.1.23304.2.2.3.1.3 |
Sets Waveguide switch Rx+Tx, Rx/Tx and Tx Only. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2 |
|
startupTime |
1.3.6.1.4.1.23304.2.2.3.1.4 |
Sets Startup time. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..50 |
|
ledState |
1.3.6.1.4.1.23304.2.2.3.1.6 |
Sets 7586 LED. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
refSource |
1.3.6.1.4.1.23304.2.2.3.1.7 |
Sets 7586 reference state. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..3 |
|
refTrim |
1.3.6.1.4.1.23304.2.2.3.1.8 |
Sets 7586 reference trim. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
refThresh |
1.3.6.1.4.1.23304.2.2.3.1.9 |
Sets 7586 reference alarm treshold. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
refPwr |
1.3.6.1.4.1.23304.2.2.3.1.10 |
Gets 7586 reference power. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
ipAddr |
1.3.6.1.4.1.23304.2.2.3.1.11 |
Gets the 7586 IP address. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
macAddress |
1.3.6.1.4.1.23304.2.2.3.1.12 |
Gets the 7586 MAC address. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
netmask |
1.3.6.1.4.1.23304.2.2.3.1.13 |
Gets the 7586 netmask. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
gateway |
1.3.6.1.4.1.23304.2.2.3.1.14 |
Gets the 7586 gateway address. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lnbCurrent |
1.3.6.1.4.1.23304.2.2.3.2.1 |
Sets 7586 LNB current. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lnbVoltage |
1.3.6.1.4.1.23304.2.2.3.2.2 |
Sets 7586 LNB voltage. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
faults |
1.3.6.1.4.1.23304.2.2.3.2.3 |
Gets the current fault status. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
idInfo |
1.3.6.1.4.1.23304.2.2.3.3.1 |
Gets the module firmware revision, serial number and model. This string
will have a zero length if the revision is unknown. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1Status |
1.3.6.1.4.1.23304.2.2.1.2 |
OBJECT IDENTIFIER |
|
|
|
buc1Info |
1.3.6.1.4.1.23304.2.2.1.3 |
OBJECT IDENTIFIER |
|
|
|
buc2Status |
1.3.6.1.4.1.23304.2.2.2.2 |
OBJECT IDENTIFIER |
|
|
|
buc2Info |
1.3.6.1.4.1.23304.2.2.2.3 |
OBJECT IDENTIFIER |
|
|
|
buc1Freqs |
1.3.6.1.4.1.23304.2.2.1.1.4 |
OBJECT IDENTIFIER |
|
|
|
buc1Misc |
1.3.6.1.4.1.23304.2.2.1.1.5 |
OBJECT IDENTIFIER |
|
|
|
buc2Freqs |
1.3.6.1.4.1.23304.2.2.2.1.4 |
OBJECT IDENTIFIER |
|
|
|
buc2Misc |
1.3.6.1.4.1.23304.2.2.2.1.5 |
OBJECT IDENTIFIER |
|
|
|
buc1TxOn |
1.3.6.1.4.1.23304.2.2.1.1.1.1 |
Sets Tx on/off. Respond -1 if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
buc2TxOn |
1.3.6.1.4.1.23304.2.2.2.1.1.1 |
Sets Tx on/off. Respond -1 if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
buc1TxDefault |
1.3.6.1.4.1.23304.2.2.1.1.1.2 |
Sets Tx default 1-last 0-off. Respond -1 if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
buc2TxDefault |
1.3.6.1.4.1.23304.2.2.2.1.1.2 |
Sets Tx default 1-last 0-off. Respond -1 if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
buc1TxAttenuator |
1.3.6.1.4.1.23304.2.2.1.1.1.3 |
Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
buc2TxAttenuator |
1.3.6.1.4.1.23304.2.2.2.1.1.3 |
Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
buc1Protocol |
1.3.6.1.4.1.23304.2.2.1.1.2.1 |
Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..4 |
|
buc2Protocol |
1.3.6.1.4.1.23304.2.2.2.1.2.1 |
Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..4 |
|
buc1Address |
1.3.6.1.4.1.23304.2.2.1.1.2.2 |
Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc2Address |
1.3.6.1.4.1.23304.2.2.2.1.2.2 |
Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc1Mode |
1.3.6.1.4.1.23304.2.2.1.1.3.1 |
Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2 |
|
buc2Mode |
1.3.6.1.4.1.23304.2.2.2.1.3.1 |
Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2 |
|
buc1OnLine |
1.3.6.1.4.1.23304.2.2.1.1.3.2 |
Sets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
buc2OnLine |
1.3.6.1.4.1.23304.2.2.2.1.3.2 |
Sets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
buc1RFFreq |
1.3.6.1.4.1.23304.2.2.1.1.4.1 |
Sets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc2RFFreq |
1.3.6.1.4.1.23304.2.2.2.1.4.1 |
Sets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc1IFFreq |
1.3.6.1.4.1.23304.2.2.1.1.4.2 |
Sets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc2IFFreq |
1.3.6.1.4.1.23304.2.2.2.1.4.2 |
Sets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc1LOFreq |
1.3.6.1.4.1.23304.2.2.1.1.4.3 |
Sets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc2LOFreq |
1.3.6.1.4.1.23304.2.2.2.1.4.3 |
Sets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc1SerIf |
1.3.6.1.4.1.23304.2.2.1.1.5.1 |
Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2SerIf |
1.3.6.1.4.1.23304.2.2.2.1.5.1 |
Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1PwrAlarmThresh |
1.3.6.1.4.1.23304.2.2.1.1.5.2 |
Sets/Gets power alarm threshold.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2PwrAlarmThresh |
1.3.6.1.4.1.23304.2.2.2.1.5.2 |
Sets/Gets power alarm threshold.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1BurstPwrThresh |
1.3.6.1.4.1.23304.2.2.1.1.5.3 |
Sets/Gets burst power threshold.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2BurstPwrThresh |
1.3.6.1.4.1.23304.2.2.2.1.5.3 |
Sets/Gets burst power threshold.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1RefSource |
1.3.6.1.4.1.23304.2.2.1.1.5.4 |
Sets/Gets reference source 0-external, 1-internal (Only for RBUC).
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2RefSource |
1.3.6.1.4.1.23304.2.2.2.1.5.4 |
Sets/Gets reference source 0-external, 1-internal (Only for RBUC).
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1LEDState |
1.3.6.1.4.1.23304.2.2.1.1.5.5 |
Sets/Gets LEDs status on/off (Only for RBUC).
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2LEDState |
1.3.6.1.4.1.23304.2.2.2.1.5.5 |
Sets/Gets LEDs status on/off (Only for RBUC).
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1PaStatus |
1.3.6.1.4.1.23304.2.2.1.2.1 |
Gets to 1 when PA is on. Respond -1 if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
buc2PaStatus |
1.3.6.1.4.1.23304.2.2.2.2.1 |
Gets to 1 when PA is on. Respond -1 if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
buc1TxPower |
1.3.6.1.4.1.23304.2.2.1.2.2 |
Gets Tx power format x.x dB.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2TxPower |
1.3.6.1.4.1.23304.2.2.2.2.2 |
Gets Tx power format x.x dB.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1TxBurstPower |
1.3.6.1.4.1.23304.2.2.1.2.3 |
Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst
power, y.y is min and z.z is max burts power.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2TxBurstPower |
1.3.6.1.4.1.23304.2.2.2.2.3 |
Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst
power, y.y is min and z.z is max burts power.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1Faults |
1.3.6.1.4.1.23304.2.2.1.2.4 |
Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault,
Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault
Bit6 LNB fault, Bit7 Red'cy Cont fault.
Respond -1 if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc2Faults |
1.3.6.1.4.1.23304.2.2.2.2.4 |
Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault,
Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault
Bit6 LNB fault, Bit7 Red'cy Cont fault.
Respond -1 if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc1LatchedFaults |
1.3.6.1.4.1.23304.2.2.1.2.5 |
Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc2LatchedFaults |
1.3.6.1.4.1.23304.2.2.2.2.5 |
Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
buc1Temperature |
1.3.6.1.4.1.23304.2.2.1.2.6 |
Gets the BUC temperature. Format is x.x.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2Temperature |
1.3.6.1.4.1.23304.2.2.2.2.6 |
Gets the BUC temperature. Format is x.x.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1MinMaxTemperature |
1.3.6.1.4.1.23304.2.2.1.2.7 |
Gets the BUC temperature. Format is x.x,y.y where x.x is max
and y.y is min temperature.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2MinMaxTemperature |
1.3.6.1.4.1.23304.2.2.2.2.7 |
Gets the BUC temperature. Format is x.x,y.y where x.x is max
and y.y is min temperature.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1SystemSetting |
1.3.6.1.4.1.23304.2.2.1.2.8 |
Gets the current system status. Format is
Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx
Bit4 - Redundancy mode, Bit5 - Online,
Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx,
Bit10 - SNMP Tx.
Respond -1 if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2047 |
|
buc2SystemSetting |
1.3.6.1.4.1.23304.2.2.2.2.8 |
Gets the current system status. Format is
Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx
Bit4 - Redundancy mode, Bit5 - Online,
Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx,
Bit10 - SNMP Tx.
Respond -1 if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2047 |
|
buc1SystemPoll |
1.3.6.1.4.1.23304.2.2.1.2.9 |
Gets the system poll status. Format is
Bit0 - Fault, Bit1 - System change.
Respond -1 if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..3 |
|
buc2SystemPoll |
1.3.6.1.4.1.23304.2.2.2.2.9 |
Gets the system poll status. Format is
Bit0 - Fault, Bit1 - System change.
Respond -1 if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..3 |
|
buc1DeviceType |
1.3.6.1.4.1.23304.2.2.1.2.10 |
Gets the device type. Format is X,Y where X is the model and
Y is software version.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2DeviceType |
1.3.6.1.4.1.23304.2.2.2.2.10 |
Gets the device type. Format is X,Y where X is the model and
Y is software version.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1Gateway |
1.3.6.1.4.1.23304.2.2.1.2.11 |
Gets the BUC gateway address (Only for RBUC).
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2Gateway |
1.3.6.1.4.1.23304.2.2.2.2.11 |
Gets the BUC gateway address (Only for RBUC).
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1IpAddress |
1.3.6.1.4.1.23304.2.2.1.2.12 |
Gets the BUC IP address (Only for RBUC).
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2IpAddress |
1.3.6.1.4.1.23304.2.2.2.2.12 |
Gets the BUC IP address (Only for RBUC).
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1MACAddress |
1.3.6.1.4.1.23304.2.2.1.2.13 |
Gets the BUC MAC address (Only for RBUC).
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2MACAddress |
1.3.6.1.4.1.23304.2.2.2.2.13 |
Gets the BUC MAC address (Only for RBUC).
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1Netmask |
1.3.6.1.4.1.23304.2.2.1.2.14 |
Gets the BUC netmask (Only for RBUC).
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2Netmask |
1.3.6.1.4.1.23304.2.2.2.2.14 |
Gets the BUC netmask (Only for RBUC).
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1RefPower |
1.3.6.1.4.1.23304.2.2.1.2.15 |
Gets the BUC reference power.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2RefPower |
1.3.6.1.4.1.23304.2.2.2.2.15 |
Gets the BUC reference power.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1Config |
1.3.6.1.4.1.23304.2.2.1.2.16 |
Gets the BUC configuration.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2Config |
1.3.6.1.4.1.23304.2.2.2.2.16 |
Gets the BUC configuration.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1BuildStandard |
1.3.6.1.4.1.23304.2.2.1.2.17 |
Gets the BUC build standard.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2BuildStandard |
1.3.6.1.4.1.23304.2.2.2.2.17 |
Gets the BUC build standard.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1IdInfo |
1.3.6.1.4.1.23304.2.2.1.3.1 |
Gets the module firmware revision, serial number and model. This string
will have a zero length if the revision is unknown.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2IdInfo |
1.3.6.1.4.1.23304.2.2.2.3.1 |
Gets the module firmware revision, serial number and model. This string
will have a zero length if the revision is unknown.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1Limits |
1.3.6.1.4.1.23304.2.2.1.3.2 |
Gets the limit data for the BUC. Format is:
Power meter MIN/MAX , IF,RF and LO frequencies.
This string will have a zero length if the revision is unknown.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2Limits |
1.3.6.1.4.1.23304.2.2.2.3.2 |
Gets the limit data for the BUC. Format is:
Power meter MIN/MAX , IF,RF and LO frequencies.
This string will have a zero length if the revision is unknown.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc1PktProtocolsInfo |
1.3.6.1.4.1.23304.2.2.1.3.3 |
Gets supported packet protocols and the corresponding address ranges.
**** No respond - message if buc1 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
buc2PktProtocolsInfo |
1.3.6.1.4.1.23304.2.2.2.3.3 |
Gets supported packet protocols and the corresponding address ranges.
**** No respond - message if buc2 not connected. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|