RC7586-MIB

File: RC7586-MIB.mib (28672 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC CODAN-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 TimeTicks IpAddress
Gauge32 Counter32 DisplayString
DateAndTime TEXTUAL-CONVENTION TestAndIncr
TimeInterval TruthValue satcomMibs

Defined Types

ComponentRevision  
The hex value in the first octet - xx - represents the major revision no. and the hex value in the second octet - yy - represents the minor revision no.
TEXTUAL-CONVENTION    
  DisplayString Size(2)  

FaultStatus7586  
Describes all the possible faults in the system as a bit pattern.
TEXTUAL-CONVENTION    
  BITS dc1fault(0), dc2fault(1), buc1fault(2), buc2fault(3), lnb1fault(4), lnb2fault(5), txswfault(6), rxswfault(7), internalfault(8), ref10mhzfault(9)  

Defined Values

rc7586MIB 1.3.6.1.4.1.23304.2.2
The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved
MODULE-IDENTITY    

buc1 1.3.6.1.4.1.23304.2.2.1
OBJECT IDENTIFIER    

buc2 1.3.6.1.4.1.23304.2.2.2
OBJECT IDENTIFIER    

ctrl 1.3.6.1.4.1.23304.2.2.3
OBJECT IDENTIFIER    

settings 1.3.6.1.4.1.23304.2.2.3.1
OBJECT IDENTIFIER    

status 1.3.6.1.4.1.23304.2.2.3.2
OBJECT IDENTIFIER    

info 1.3.6.1.4.1.23304.2.2.3.3
OBJECT IDENTIFIER    

operationalMode 1.3.6.1.4.1.23304.2.2.3.1.1
Sets 7586 operational mode - Auto, Manual Stream1, Stream2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..2  

onlineStream 1.3.6.1.4.1.23304.2.2.3.1.2
Sets the online stream.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..2  

waveguideSwitch 1.3.6.1.4.1.23304.2.2.3.1.3
Sets Waveguide switch Rx+Tx, Rx/Tx and Tx Only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..2  

startupTime 1.3.6.1.4.1.23304.2.2.3.1.4
Sets Startup time.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..50  

lnbCurrentLimit 1.3.6.1.4.1.23304.2.2.3.1.5
Sets LNB current limits.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ledState 1.3.6.1.4.1.23304.2.2.3.1.6
Sets 7586 LED.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

refSource 1.3.6.1.4.1.23304.2.2.3.1.7
Sets 7586 reference state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

refTrim 1.3.6.1.4.1.23304.2.2.3.1.8
Sets 7586 reference trim.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

refThresh 1.3.6.1.4.1.23304.2.2.3.1.9
Sets 7586 reference alarm treshold.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

refPwr 1.3.6.1.4.1.23304.2.2.3.1.10
Gets 7586 reference power.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ipAddr 1.3.6.1.4.1.23304.2.2.3.1.11
Gets the 7586 IP address.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

macAddress 1.3.6.1.4.1.23304.2.2.3.1.12
Gets the 7586 MAC address.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

netmask 1.3.6.1.4.1.23304.2.2.3.1.13
Gets the 7586 netmask.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

gateway 1.3.6.1.4.1.23304.2.2.3.1.14
Gets the 7586 gateway address.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

lnbCurrent 1.3.6.1.4.1.23304.2.2.3.2.1
Sets 7586 LNB current.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

lnbVoltage 1.3.6.1.4.1.23304.2.2.3.2.2
Sets 7586 LNB voltage.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

faults 1.3.6.1.4.1.23304.2.2.3.2.3
Gets the current fault status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

idInfo 1.3.6.1.4.1.23304.2.2.3.3.1
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1Configuration 1.3.6.1.4.1.23304.2.2.1.1
OBJECT IDENTIFIER    

buc1Status 1.3.6.1.4.1.23304.2.2.1.2
OBJECT IDENTIFIER    

buc1Info 1.3.6.1.4.1.23304.2.2.1.3
OBJECT IDENTIFIER    

buc2Configuration 1.3.6.1.4.1.23304.2.2.2.1
OBJECT IDENTIFIER    

buc2Status 1.3.6.1.4.1.23304.2.2.2.2
OBJECT IDENTIFIER    

buc2Info 1.3.6.1.4.1.23304.2.2.2.3
OBJECT IDENTIFIER    

buc1TxSettings 1.3.6.1.4.1.23304.2.2.1.1.1
OBJECT IDENTIFIER    

buc1PktProtocol 1.3.6.1.4.1.23304.2.2.1.1.2
OBJECT IDENTIFIER    

buc1RCSetting 1.3.6.1.4.1.23304.2.2.1.1.3
OBJECT IDENTIFIER    

buc1Freqs 1.3.6.1.4.1.23304.2.2.1.1.4
OBJECT IDENTIFIER    

buc1Misc 1.3.6.1.4.1.23304.2.2.1.1.5
OBJECT IDENTIFIER    

buc2TxSettings 1.3.6.1.4.1.23304.2.2.2.1.1
OBJECT IDENTIFIER    

buc2PktProtocol 1.3.6.1.4.1.23304.2.2.2.1.2
OBJECT IDENTIFIER    

buc2RCSetting 1.3.6.1.4.1.23304.2.2.2.1.3
OBJECT IDENTIFIER    

buc2Freqs 1.3.6.1.4.1.23304.2.2.2.1.4
OBJECT IDENTIFIER    

buc2Misc 1.3.6.1.4.1.23304.2.2.2.1.5
OBJECT IDENTIFIER    

buc1TxOn 1.3.6.1.4.1.23304.2.2.1.1.1.1
Sets Tx on/off. Respond -1 if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

buc2TxOn 1.3.6.1.4.1.23304.2.2.2.1.1.1
Sets Tx on/off. Respond -1 if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

buc1TxDefault 1.3.6.1.4.1.23304.2.2.1.1.1.2
Sets Tx default 1-last 0-off. Respond -1 if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

buc2TxDefault 1.3.6.1.4.1.23304.2.2.2.1.1.2
Sets Tx default 1-last 0-off. Respond -1 if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

buc1TxAttenuator 1.3.6.1.4.1.23304.2.2.1.1.1.3
Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

buc2TxAttenuator 1.3.6.1.4.1.23304.2.2.2.1.1.3
Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

buc1Protocol 1.3.6.1.4.1.23304.2.2.1.1.2.1
Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4  

buc2Protocol 1.3.6.1.4.1.23304.2.2.2.1.2.1
Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4  

buc1Address 1.3.6.1.4.1.23304.2.2.1.1.2.2
Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

buc2Address 1.3.6.1.4.1.23304.2.2.2.1.2.2
Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

buc1Mode 1.3.6.1.4.1.23304.2.2.1.1.3.1
Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..2  

buc2Mode 1.3.6.1.4.1.23304.2.2.2.1.3.1
Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..2  

buc1OnLine 1.3.6.1.4.1.23304.2.2.1.1.3.2
Sets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

buc2OnLine 1.3.6.1.4.1.23304.2.2.2.1.3.2
Sets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

buc1RFFreq 1.3.6.1.4.1.23304.2.2.1.1.4.1
Sets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

buc2RFFreq 1.3.6.1.4.1.23304.2.2.2.1.4.1
Sets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

buc1IFFreq 1.3.6.1.4.1.23304.2.2.1.1.4.2
Sets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

buc2IFFreq 1.3.6.1.4.1.23304.2.2.2.1.4.2
Sets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

buc1LOFreq 1.3.6.1.4.1.23304.2.2.1.1.4.3
Sets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

buc2LOFreq 1.3.6.1.4.1.23304.2.2.2.1.4.3
Sets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

buc1SerIf 1.3.6.1.4.1.23304.2.2.1.1.5.1
Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

buc2SerIf 1.3.6.1.4.1.23304.2.2.2.1.5.1
Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

buc1PwrAlarmThresh 1.3.6.1.4.1.23304.2.2.1.1.5.2
Sets/Gets power alarm threshold. **** No respond - message if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

buc2PwrAlarmThresh 1.3.6.1.4.1.23304.2.2.2.1.5.2
Sets/Gets power alarm threshold. **** No respond - message if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

buc1BurstPwrThresh 1.3.6.1.4.1.23304.2.2.1.1.5.3
Sets/Gets burst power threshold. **** No respond - message if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

buc2BurstPwrThresh 1.3.6.1.4.1.23304.2.2.2.1.5.3
Sets/Gets burst power threshold. **** No respond - message if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

buc1RefSource 1.3.6.1.4.1.23304.2.2.1.1.5.4
Sets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

buc2RefSource 1.3.6.1.4.1.23304.2.2.2.1.5.4
Sets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

buc1LEDState 1.3.6.1.4.1.23304.2.2.1.1.5.5
Sets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc1 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

buc2LEDState 1.3.6.1.4.1.23304.2.2.2.1.5.5
Sets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc2 not connected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

buc1PaStatus 1.3.6.1.4.1.23304.2.2.1.2.1
Gets to 1 when PA is on. Respond -1 if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

buc2PaStatus 1.3.6.1.4.1.23304.2.2.2.2.1
Gets to 1 when PA is on. Respond -1 if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

buc1TxPower 1.3.6.1.4.1.23304.2.2.1.2.2
Gets Tx power format x.x dB. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2TxPower 1.3.6.1.4.1.23304.2.2.2.2.2
Gets Tx power format x.x dB. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1TxBurstPower 1.3.6.1.4.1.23304.2.2.1.2.3
Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2TxBurstPower 1.3.6.1.4.1.23304.2.2.2.2.3
Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1Faults 1.3.6.1.4.1.23304.2.2.1.2.4
Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

buc2Faults 1.3.6.1.4.1.23304.2.2.2.2.4
Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

buc1LatchedFaults 1.3.6.1.4.1.23304.2.2.1.2.5
Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

buc2LatchedFaults 1.3.6.1.4.1.23304.2.2.2.2.5
Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

buc1Temperature 1.3.6.1.4.1.23304.2.2.1.2.6
Gets the BUC temperature. Format is x.x. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2Temperature 1.3.6.1.4.1.23304.2.2.2.2.6
Gets the BUC temperature. Format is x.x. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1MinMaxTemperature 1.3.6.1.4.1.23304.2.2.1.2.7
Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2MinMaxTemperature 1.3.6.1.4.1.23304.2.2.2.2.7
Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1SystemSetting 1.3.6.1.4.1.23304.2.2.1.2.8
Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2047  

buc2SystemSetting 1.3.6.1.4.1.23304.2.2.2.2.8
Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2047  

buc1SystemPoll 1.3.6.1.4.1.23304.2.2.1.2.9
Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

buc2SystemPoll 1.3.6.1.4.1.23304.2.2.2.2.9
Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

buc1DeviceType 1.3.6.1.4.1.23304.2.2.1.2.10
Gets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2DeviceType 1.3.6.1.4.1.23304.2.2.2.2.10
Gets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1Gateway 1.3.6.1.4.1.23304.2.2.1.2.11
Gets the BUC gateway address (Only for RBUC). **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2Gateway 1.3.6.1.4.1.23304.2.2.2.2.11
Gets the BUC gateway address (Only for RBUC). **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1IpAddress 1.3.6.1.4.1.23304.2.2.1.2.12
Gets the BUC IP address (Only for RBUC). **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2IpAddress 1.3.6.1.4.1.23304.2.2.2.2.12
Gets the BUC IP address (Only for RBUC). **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1MACAddress 1.3.6.1.4.1.23304.2.2.1.2.13
Gets the BUC MAC address (Only for RBUC). **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2MACAddress 1.3.6.1.4.1.23304.2.2.2.2.13
Gets the BUC MAC address (Only for RBUC). **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1Netmask 1.3.6.1.4.1.23304.2.2.1.2.14
Gets the BUC netmask (Only for RBUC). **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2Netmask 1.3.6.1.4.1.23304.2.2.2.2.14
Gets the BUC netmask (Only for RBUC). **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1RefPower 1.3.6.1.4.1.23304.2.2.1.2.15
Gets the BUC reference power. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2RefPower 1.3.6.1.4.1.23304.2.2.2.2.15
Gets the BUC reference power. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1Config 1.3.6.1.4.1.23304.2.2.1.2.16
Gets the BUC configuration. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2Config 1.3.6.1.4.1.23304.2.2.2.2.16
Gets the BUC configuration. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1BuildStandard 1.3.6.1.4.1.23304.2.2.1.2.17
Gets the BUC build standard. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2BuildStandard 1.3.6.1.4.1.23304.2.2.2.2.17
Gets the BUC build standard. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1IdInfo 1.3.6.1.4.1.23304.2.2.1.3.1
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2IdInfo 1.3.6.1.4.1.23304.2.2.2.3.1
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1Limits 1.3.6.1.4.1.23304.2.2.1.3.2
Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2Limits 1.3.6.1.4.1.23304.2.2.2.3.2
Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc1PktProtocolsInfo 1.3.6.1.4.1.23304.2.2.1.3.3
Gets supported packet protocols and the corresponding address ranges. **** No respond - message if buc1 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

buc2PktProtocolsInfo 1.3.6.1.4.1.23304.2.2.2.3.3
Gets supported packet protocols and the corresponding address ranges. **** No respond - message if buc2 not connected.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString