RC-POM-MIB

File: RC-POM-MIB.mib (38230 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IF-MIB
RAPID-CITY

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
DisplayString TruthValue InterfaceIndex
rcPlugOptMod EnableValue

Defined Types

RcPlugOptModEntry  
SEQUENCE    
  rcPlugOptModPortIndex InterfaceIndex
  rcPlugOptModDdmStatusMask BITS
  rcPlugOptModCalibration INTEGER
  rcPlugOptModPowerMeasure INTEGER
  rcPlugOptModConnectorType DisplayString
  rcPlugOptModVendorName DisplayString
  rcPlugOptModVendorPartNumber DisplayString
  rcPlugOptModVendorRevNumber DisplayString
  rcPlugOptModVendorSN DisplayString
  rcPlugOptModVendorDateCode DisplayString
  rcPlugOptModPEC DisplayString
  rcPlugOptModCLEI DisplayString
  rcPlugOptModSupportsDDM TruthValue
  rcPlugOptModAux1Monitoring INTEGER
  rcPlugOptModAux2Monitoring INTEGER
  rcPlugOptModWaveLength Integer32
  rcPlugOptModTemperature Integer32
  rcPlugOptModTemperatureHighAlarmThreshold Integer32
  rcPlugOptModTemperatureLowAlarmThreshold Integer32
  rcPlugOptModTemperatureHighWarningThreshold Integer32
  rcPlugOptModTemperatureLowWarningThreshold Integer32
  rcPlugOptModVoltage Integer32
  rcPlugOptModVoltageHighAlarmThreshold Integer32
  rcPlugOptModVoltageLowAlarmThreshold Integer32
  rcPlugOptModVoltageHighWarningThreshold Integer32
  rcPlugOptModVoltageLowWarningThreshold Integer32
  rcPlugOptModBias Integer32
  rcPlugOptModBiasHighAlarmThreshold Integer32
  rcPlugOptModBiasLowAlarmThreshold Integer32
  rcPlugOptModBiasHighWarningThreshold Integer32
  rcPlugOptModBiasLowWarningThreshold Integer32
  rcPlugOptModTxPower Integer32
  rcPlugOptModTxPowerHighAlarmThreshold Integer32
  rcPlugOptModTxPowerLowAlarmThreshold Integer32
  rcPlugOptModTxPowerHighWarningThreshold Integer32
  rcPlugOptModTxPowerLowWarningThreshold Integer32
  rcPlugOptModRxPower Integer32
  rcPlugOptModRxPowerHighAlarmThreshold Integer32
  rcPlugOptModRxPowerLowAlarmThreshold Integer32
  rcPlugOptModRxPowerHighWarningThreshold Integer32
  rcPlugOptModRxPowerLowWarningThreshold Integer32
  rcPlugOptModAux1 Integer32
  rcPlugOptModAux1HighAlarmThreshold Integer32
  rcPlugOptModAux1LowAlarmThreshold Integer32
  rcPlugOptModAux1HighWarningThreshold Integer32
  rcPlugOptModAux1LowWarningThreshold Integer32
  rcPlugOptModAux2 Integer32
  rcPlugOptModAux2HighAlarmThreshold Integer32
  rcPlugOptModAux2LowAlarmThreshold Integer32
  rcPlugOptModAux2HighWarningThreshold Integer32
  rcPlugOptModAux2LowWarningThreshold Integer32
  rcPlugOptModTemperatureStatus INTEGER
  rcPlugOptModVoltageStatus INTEGER
  rcPlugOptModBiasStatus INTEGER
  rcPlugOptModTxPowerStatus INTEGER
  rcPlugOptModRxPowerStatus INTEGER
  rcPlugOptModAux1Status INTEGER
  rcPlugOptModAux2Status INTEGER

Defined Values

rcPlugOptModTableMib 1.3.6.1.4.1.2272.1.71.0
OE MIB for Digital Diagnostic Monitoring of pluggable optical modules
MODULE-IDENTITY    

rcPlugOptModTable 1.3.6.1.4.1.2272.1.71.1
Gibc SFF diagnostic info table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RcPlugOptModEntry

rcPlugOptModEntry 1.3.6.1.4.1.2272.1.71.1.1
Entry containing info. for a particular port
Status: current Access: not-accessible
OBJECT-TYPE    
  RcPlugOptModEntry  

rcPlugOptModPortIndex 1.3.6.1.4.1.2272.1.71.1.1.1
An index value that uniquely identifies a port on a blade or line-card.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

rcPlugOptModDdmStatusMask 1.3.6.1.4.1.2272.1.71.1.1.2
Each bit other than ddm-ok represents a specific error. Any combination of error bits is allowed.
Status: current Access: read-only
OBJECT-TYPE    
  BITS ddm-ok(0), ddm-checksum-error(1), ddm-i2c-read-error(2), ddm-threshold-error(3), ddm-calibration-error(4)  

rcPlugOptModCalibration 1.3.6.1.4.1.2272.1.71.1.1.3
The identifier value indicates type of calibration.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER internal(1), external(2)  

rcPlugOptModPowerMeasure 1.3.6.1.4.1.2272.1.71.1.1.4
The identifier value indicates type of external power.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER omi(1), average(2)  

rcPlugOptModConnectorType 1.3.6.1.4.1.2272.1.71.1.1.5
The connector type is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces. This is an assigned name that indicates some characteristic of the layer-1 interface.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(17)  

rcPlugOptModVendorName 1.3.6.1.4.1.2272.1.71.1.1.6
The vendor name is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces. The vendor name shall be the full name of the corporation, a commonly accepted abbreviation of the name, the SCSI company code, or the stock exchange code for the corporation.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(17)  

rcPlugOptModVendorPartNumber 1.3.6.1.4.1.2272.1.71.1.1.7
The vendor part number is a 16 byte field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces, defining the vendor part number or product name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(17)  

rcPlugOptModVendorRevNumber 1.3.6.1.4.1.2272.1.71.1.1.8
The vendor revision number is a 4-byte field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces, defining the vendor product revision number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(5)  

rcPlugOptModVendorSN 1.3.6.1.4.1.2272.1.71.1.1.9
The vendor serial number is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces, defining the vendor serial number for the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(17)  

rcPlugOptModVendorDateCode 1.3.6.1.4.1.2272.1.71.1.1.10
The date code is an 8-byte field that contains the vendor's date code in ASCII. This field is mandatory and takes the form: YYMMDDLC where YY is the 2 low order digits of the year (00=2000), MM is the month, 01 thru 12, DD is the day, 01 thru 31, and LC is an optional vendor specific lot code.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(9)  

rcPlugOptModPEC 1.3.6.1.4.1.2272.1.71.1.1.11
This is a 16 byte left-justified ASCII field that records the Nortel Product Equipment Code order number for the module. Nortel part numbers are 9 bytes long, so the 10th through 16th byte should be NULL.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(17)  

rcPlugOptModCLEI 1.3.6.1.4.1.2272.1.71.1.1.12
This is a 10 byte left-justified ASCII field that records the Nortel supplied Common Language Equipment Identifier code for the device. The CLEI code is a Telcordia human-readable representation of the 1D barcode.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(11)  

rcPlugOptModSupportsDDM 1.3.6.1.4.1.2272.1.71.1.1.13
This boolean indicates whether or not the device supports the DDM capability.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

rcPlugOptModAux1Monitoring 1.3.6.1.4.1.2272.1.71.1.1.14
This value tells what Aux1 is measuring.The values are as follows: 0 Auxiliary monitoring not implemented 1 APD Bias Voltage mV (units of 10 mV) 2 Reserved 3 TEC Current (mA) 4 Laser Temperature 5 Laser Wavelength 6 +5V Supply Voltage 7 +3.3V Supply Voltage 8 +1.8V Supply Voltage 9 -5.2V Supply Voltage 10 +5.0V Supply Current (unit of 100 uA) 13 +3.3V Supply Current (unit of 100 uA) 14 +1.8V Supply Current (unit of 100 uA) 15 -5.2V Supply Current (unit of 100 uA)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

rcPlugOptModAux2Monitoring 1.3.6.1.4.1.2272.1.71.1.1.15
This value tells you what AUX2 is measuring.The values are as follows: 0 Auxiliary monitoring not implemented 1 APD Bias Voltage mV (units of 10 mV) 2 Reserved 3 TEC Current (mA) 4 Laser Temperature 5 Laser Wavelength 6 +5V Supply Voltage 7 +3.3V Supply Voltage 8 +1.8V Supply Voltage 9 -5.2V Supply Voltage 10 +5.0V Supply Current (unit of 100 uA) 13 +3.3V Supply Current (unit of 100 uA) 14 +1.8V Supply Current (unit of 100 uA) 15 -5.2V Supply Current (unit of 100 uA)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

rcPlugOptModWaveLength 1.3.6.1.4.1.2272.1.71.1.1.16
Nominal transmitter output wavelength at room temperature. It is expressed in nano-meters.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

rcPlugOptModTemperature 1.3.6.1.4.1.2272.1.71.1.1.17
This value represents the internally measured module temperature. It is expressed in units of 1/256 of a degree Celsius and can range from -40C to +125C with 0.0001 accuracy.The most significant byte is the signed integer part of the number and the least significant byte is the fraction.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModTemperatureHighAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.18
This value represents the vendor specified high temperature threshold. If the device temperature exceeds this value, a temperature high is asserted. It is expressed in the same units as the measured temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModTemperatureLowAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.19
This value represents the vendor specified low temperature threshold. If the device temperature falls below this value, a temperature low is asserted. It is expressed in the same units as the measured temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModTemperatureHighWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.20
This value represents the vendor specified high temperature warning threshold. If the device temperature exceeds this value, a temperature high warning is asserted. It is expressed in the same units as the measured temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModTemperatureLowWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.21
This value represents the vendor specified low temperature warning threshold. If the device temperature falls below this value, a temperature low warning is asserted. It is expressed in the same units as the measured temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModVoltage 1.3.6.1.4.1.2272.1.71.1.1.22
This value represents the internally measured supply voltage. It is a positive number expressed in microvolts and can range from 0 to 65535 mV.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModVoltageHighAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.23
This value represents the vendor specified high voltage threshold. If the measured voltage exceeds this value, a high voltage is asserted. It is a positive number expressed in microvolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModVoltageLowAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.24
This value represents the vendor specified low voltage threshold. If the measured voltage falls below this value, a low voltage is asserted. It is a positive number expressed in microvolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModVoltageHighWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.25
This value represents the vendor specified high voltage warning threshold. If the measured voltage exceeds this value, a high voltage warning is asserted. It is a positive number expressed in microvolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModVoltageLowWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.26
This value represents the vendor specified low voltage warning threshold. If the measured voltage falls below this value, a low voltage warning is asserted. It is a positive number expressed in microvolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModBias 1.3.6.1.4.1.2272.1.71.1.1.27
This value represents the internally measured transmitter laser bias current. It is a positive number expressed in units of 2 microamps and can range from 0 to 131 mA with 0.0001 accuracy.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModBiasHighAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.28
This value represents the vendor specified high current threshold. If the measured bias current exceeds this value, a high current alarm is asserted. It is a positive number expressed in units of 2 microamps and can range from 0 to 131 mA with 0.0001 accuracy.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModBiasLowAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.29
This value represents the vendor specified low current threshold. If the measured bias current falls below this value, a low current is asserted. It is a positive number expressed in units of 2 microamps and can range from 0 to 131 mA with 0.0001 accuracy.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModBiasHighWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.30
This value represents the vendor specified high current warning threshold. If the measured bias current exceeds this value, a high current warning is asserted. It is a positive number expressed in units of 2 microamps and can range from 0 to 131 mA with 0.0001 accuracy.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModBiasLowWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.31
This value represents the vendor specified low current warning threshold. If the measured bias current falls below this value, a low current warning is asserted. It is a positive number expressed in units of 2 microamps and can range from 0 to 131 mA with 0.0001 accuracy.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModTxPower 1.3.6.1.4.1.2272.1.71.1.1.32
This value represents the internally measured coupled TX output power. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModTxPowerHighAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.33
This value represents the vendor specified high transmit power threshold. If the measured transmitter power exceeds this value, a transmitter power high is asserted. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModTxPowerLowAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.34
This value represents the vendor specified low transmit power threshold. If the measured transmitter power falls below this value, a transmitter power low is asserted. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModTxPowerHighWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.35
This value represents the vendor specified high transmit power warning threshold. If the measured transmitter power exceeds this value, a transmitter power high warning is asserted. It is a positive number expressed in units of units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModTxPowerLowWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.36
This value represents the vendor specified low transmit power warning threshold. If the measured transmitter power falls below this value, a transmitter power low warning is asserted. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModRxPower 1.3.6.1.4.1.2272.1.71.1.1.37
This value represents the internally measured received power. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModRxPowerHighAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.38
This value represents the vendor specified high receiver power threshold. If the measured received power exceeds this value, a receiver power high is asserted. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModRxPowerLowAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.39
This value represents the vendor specified low receiver power threshold. If the measured received power falls below this value, a receiver power low is asserted. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModRxPowerHighWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.40
This value represents the vendor specified high receiver power warning threshold. If the measured received power exceeds this value, a receiver power high warning is asserted. It is a positive number expressed in units of units of micro watts and can range from 0 to 65.535 uW (-40 to 18.16 dBm).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModRxPowerLowWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.41
This value represents the vendor specified low receiver power warning threshold. If the measured received power falls below this value, a receiver power low warning is asserted. It is a positive number expressed in units of units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModAux1 1.3.6.1.4.1.2272.1.71.1.1.42
This represents the internally measured A/D value specified.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModAux1HighAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.43
This value represents the vendor specified high Aux1 threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModAux1LowAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.44
This value represents the vendor specified low Aux1 threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModAux1HighWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.45
This value represents the vendor specified high Aux1 warning threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModAux1LowWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.46
This value represents the vendor specified low Aux1 warning threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModAux2 1.3.6.1.4.1.2272.1.71.1.1.47
This represents the internally measured A/D value specified.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModAux2HighAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.48
This value represents the vendor specified high Aux1 threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModAux2LowAlarmThreshold 1.3.6.1.4.1.2272.1.71.1.1.49
This value represents the vendor specified low Aux1 threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModAux2HighWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.50
This value represents the vendor specified high Aux1 warning threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModAux2LowWarningThreshold 1.3.6.1.4.1.2272.1.71.1.1.51
This value represents the vendor specified low Aux1 warning threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rcPlugOptModTemperatureStatus 1.3.6.1.4.1.2272.1.71.1.1.52
Used to indicate the current temperature status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), highWarning(2), highAlarm(3), lowWarning(4), lowAlarm(5)  

rcPlugOptModVoltageStatus 1.3.6.1.4.1.2272.1.71.1.1.53
Used to indicate the current voltage status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), highWarning(2), highAlarm(3), lowWarning(4), lowAlarm(5)  

rcPlugOptModBiasStatus 1.3.6.1.4.1.2272.1.71.1.1.54
Used to indicate the current laser bias status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), highWarning(2), highAlarm(3), lowWarning(4), lowAlarm(5)  

rcPlugOptModTxPowerStatus 1.3.6.1.4.1.2272.1.71.1.1.55
Used to indicate the current transmitter power status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), highWarning(2), highAlarm(3), lowWarning(4), lowAlarm(5)  

rcPlugOptModRxPowerStatus 1.3.6.1.4.1.2272.1.71.1.1.56
Used to indicate the current receiver power status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), highWarning(2), highAlarm(3), lowWarning(4), lowAlarm(5)  

rcPlugOptModAux1Status 1.3.6.1.4.1.2272.1.71.1.1.57
Used to indicate the current Aux1 status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), highWarning(2), highAlarm(3), lowWarning(4), lowAlarm(5)  

rcPlugOptModAux2Status 1.3.6.1.4.1.2272.1.71.1.1.58
Used to indicate the current Aux2 status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), highWarning(2), highAlarm(3), lowWarning(4), lowAlarm(5)  

rcPlugOptModScalars 1.3.6.1.4.1.2272.1.71.2
OBJECT IDENTIFIER    

rcPlugOptModDdmMonitor 1.3.6.1.4.1.2272.1.71.2.1
Enable/disable the global polling monitor for DDM
Status: current Access: read-write
OBJECT-TYPE    
  EnableValue  

rcPlugOptModDdmMonitorInterval 1.3.6.1.4.1.2272.1.71.2.2
Indicate the interval in which the DDM alert registers is polled
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 5..60  

rcPlugOptModDdmTrapSend 1.3.6.1.4.1.2272.1.71.2.3
Enable/disable the global ddm trap send to SNMP manager
Status: current Access: read-write
OBJECT-TYPE    
  EnableValue  

rcPlugOptModDdmAlarmPortdown 1.3.6.1.4.1.2272.1.71.2.4
Enable/disable the global portdown option when ddm alarm occurs
Status: current Access: read-write
OBJECT-TYPE    
  EnableValue