OpticalParameterValue |
|
The value of the optical parameter that is being monitored.
The range of values varies depending on the type of optical parameter being monitored,
as identified by a corresponding object with syntax OpticalParameterType.
When the optical parameter being monitored is 'XXTemperature',the supported range
is from -40000 to 125000, in units of 1/1000 degrees centigrade.
Example: A value of 23500 represents a temperature reading of 23.5 degrees C.
The temperature is shown in unit of degrees centigrade, and the precision is 0.1.
When the optical parameter being monitored is 'txbiasCurrent',the supported range
is from 0 to 131000, in units of 1/1000 mA.
Example: A value of 1000 represents a TX bias current reading of 1.0mA.
The 'txbiasCurrent'is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'txPower',the supported range
is from -40000 to 8200, in units of 1/1000 dbm.
Example: A value of 77800 represents a TX output power reading of 7.78 dBm.
The 'txPower' is shown in unit of dBm, and the precision is 0.1.
When the optical parameter being monitored is 'rxPower',the supported range
is from -40000 to 8200, in units of 1/1000 dbm.
Example: A value of 7780 represents a RX received optical power reading of 7.78 dBm.
The 'rxPower' is shown in unit of dBm, and the precision is 0.1.
When the optical parameter being monitored is 'XXsupplyVoltage',the supported range
is from 0 to 6550, in units of 1/1000 V.
Example: A value of 6000 represents a XX supply Voltage eading of 6.00V.
The 'XXsupplyVoltage'is shown in unit of V, and the precision is 0.01.
When the optical parameter being monitored is 'apdBiasVoltage,the supported range
is from 0 to 655300 , in units of 1/1000 V .
Example: A value of 600000 represents a APD BiasVoltage reading of 600.0V.
The 'apdBiasVoltage' is shown in unit of V, and the precision is 0.1.
When the optical parameter being monitored is 'XXsupplyCurrent',the supported range
is from 0 to 6553600, in units of 1/1000 mA .
Example: A value of 6000000 represents a XX supply current reading of 6000.0mA.
The 'XXsupplyCurrent' is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'tecCurrent',the supported range
is from 0 to 6553600, in units of 1/1000 mA .
Example: A value of 6000000 represents a TEC Current reading of 6000.0mA.
The 'tecCurrent' is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'laserWavelength,the supported range
is from 0 to 3276750, in units of 1/1000 nm .
Example: A value of 3000000 represents a laser wavelength reading of 3000.0nm.
The 'laserWavelength'is shown in unit of nm, and the precision is 0.01.
|
TEXTUAL-CONVENTION |
|
|
|
|
Integer32 |
-1000000 | -40000..6553600 |
|
RaisecomOpticalTransceiverInfoEntry |
|
SEQUENCE |
|
|
|
|
raisecomOpticalTransceiverType |
INTEGER |
|
|
raisecomOpticalTransceiverConnectorType |
INTEGER |
|
|
raisecomOpticalTransceiverVendorName |
OCTET STRING |
|
|
raisecomOpticalTransceiverVendorPN |
OCTET STRING |
|
|
raisecomOpticalTransceiverVendorSN |
OCTET STRING |
|
|
raisecomOpticalTransceiverMediaType |
INTEGER |
|
|
raisecomOpticalTransceiverTransmissionDistance |
Integer32 |
|
|
raisecomOpticalTransceiverAbility |
Unsigned32 |
|
|
raisecomOpticalTransceiverDDM |
INTEGER |
|
|
raisecomOpticalTransceiverCalibrationType |
INTEGER |
|
|
raisecomOpticalTransceiverRSSI |
INTEGER |
|
|
raisecomOpticalTransceiverVendorRev |
OCTET STRING |
|
|
raisecomOpticalTransceiverBRMax |
INTEGER |
|
|
raisecomOpticalTransceiverBRMin |
INTEGER |
|
|
raisecomOpticalTransceiverWavelengthContrl |
INTEGER |
|
|
raisecomOpticalTransceiverWavelength |
Integer32 |
|
|
raisecomOpticalTransceiverWaveTolerance |
OCTET STRING |
|
|
raisecomOpticalTransceiverCompatibility |
OCTET STRING |
|
|
raisecomOpticalTransceiverPowerDissipation |
INTEGER |
|
|
raisecomOpticalTransceiverCDR |
INTEGER |
|
|
raisecomOpticalTransceiverRefClock |
INTEGER |
|
|
raisecomOpticalTransceiverTransmitterType |
INTEGER |
|
|
raisecomOpticalTransceiverCooled |
INTEGER |
|
|
raisecomOpticalTransceiverTunalbe |
INTEGER |
|
|
raisecomOpticalTransceiverDetectorType |
INTEGER |
|
|
raisecomOpticalTransceiverLineLoopBack |
INTEGER |
|
|
raisecomOpticalTransceiverXFILoopBack |
INTEGER |
|
|
raisecomOpticalTransceiverVps |
INTEGER |
|
|
raisecomOpticalTransceiverTxDis |
INTEGER |
|
|
raisecomOpticalTransceiverStandby |
INTEGER |
|
|
raisecomOpticalTransceiverInVpsLowPower |
INTEGER |
|
|
raisecomOpticalTransceiverOutVpsLowPower |
INTEGER |
|
|
raisecomOpticalTransceiverFEC |
INTEGER |
|
|
raisecomOpticalTransceiverCMU |
INTEGER |
|
|
raisecomOpticalTransceiverBR |
INTEGER |
|
RaisecomOpticalTransceiverDDMEntry |
|
SEQUENCE |
|
|
|
|
raisecomOpticalTransceiverParameterType |
OpticalParameterType |
|
|
raisecomOpticalTransceiverParameterValue |
OpticalParameterValue |
|
|
raisecomOpticalTransceiverParamHighAlarmThresh |
OpticalParameterValue |
|
|
raisecomOpticalTransceiverParamHighWarningThresh |
OpticalParameterValue |
|
|
raisecomOpticalTransceiverParamLowAlarmThresh |
OpticalParameterValue |
|
|
raisecomOpticalTransceiverParamLowWarningThresh |
OpticalParameterValue |
|
|
raisecomOpticalTransceiverParamAlarmStatus |
INTEGER |
|
|
raisecomOpticalTransceiverParamAlarmLastValue |
OpticalParameterValue |
|
|
raisecomOpticalTransceiverParamAlarmLastChange |
TimeTicks |
|
|
raisecomOpticalTransceiverDDM15MinValidIntervals |
Unsigned32 |
|
|
raisecomOpticalTransceiverDDM24HrValidIntervals |
Unsigned32 |
|
|
raisecomOpticalTransceiverDDMValidStatus |
INTEGER |
|
RaisecomOpticalTransceiverPMCurrentEntry |
|
SEQUENCE |
|
|
|
|
raisecomOpticalTransceiverPMCurrentPeriod |
OpticalPMPeriod |
|
|
raisecomOpticalTransceiverPMCurrentParamType |
OpticalParameterType |
|
|
raisecomOpticalTransceiverPMCurrentMaxParam |
OpticalParameterValue |
|
|
raisecomOpticalTransceiverPMCurrentMinParam |
OpticalParameterValue |
|
|
raisecomOpticalTransceiverPMCurrentMeanParam |
OpticalParameterValue |
|
RaisecomOpticalTransceiverPMIntervalEntry |
|
SEQUENCE |
|
|
|
|
raisecomOpticalTransceiverPMIntervalPeriod |
OpticalPMPeriod |
|
|
raisecomOpticalTransceiverPMIntervalNumber |
Integer32 |
|
|
raisecomOpticalTransceiverPMIntervalParamType |
OpticalParameterType |
|
|
raisecomOpticalTransceiverPMIntervalMaxParam |
OpticalParameterValue |
|
|
raisecomOpticalTransceiverPMIntervalMinParam |
OpticalParameterValue |
|
|
raisecomOpticalTransceiverPMIntervalMeanParam |
OpticalParameterValue |
|
RaisecomOpticalTransceiverCurrentStatusEntry |
|
SEQUENCE |
|
|
|
|
raisecomOpticalTransceiverHwInfoAbsStatus |
INTEGER |
|
|
raisecomOpticalTransceiverHwInfoNRStatus |
INTEGER |
|
|
raisecomOpticalTransceiverHwInfoRxLosStatus |
INTEGER |
|
|
raisecomOpticalTransceiverHwInfoStandby |
INTEGER |
|
|
raisecomOpticalTransceiverHwInfoLaser |
INTEGER |
|
|
raisecomOpticalTransceiverWaveLengthError |
Integer32 |
|
|
raisecomOpticalTransceiverUserWaveLength |
Integer32 |
|
|
raisecomOpticalTransceiverUserDataRate |
INTEGER |
|
|
raisecomOpticalTransceiverUserLineLoopBack |
INTEGER |
|
|
raisecomOpticalTransceiverUserXFILoopBack |
INTEGER |
|
|
raisecomOpticalTransceiverPortNotifyEnable |
EnableVar |
|
|
raisecomOpticalTransceiverPortDDMEnable |
EnableVar |
|
|
raisecomOpticalTransceiverPortCheckPwdEnable |
EnableVar |
|
|
raisecomOpticalTransceiverTxFaultCount |
Integer32 |
|
|
raisecomOpticalTransceiverTxFaultCountClear |
ClearVar |
|
|
raisecomOpticalTransceiverSpecificationCheckStatus |
INTEGER |
|
|
raisecomOpticalTransceiverTxFaultStatus |
INTEGER |
|
raisecomOpticalTransceiverInfoEntry |
1.3.6.1.4.1.8886.1.18.2.1.1.1 |
An entry in the raisecomOpticalTransceiverInfoTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RaisecomOpticalTransceiverInfoEntry |
|
|
raisecomOpticalTransceiverConnectorType |
1.3.6.1.4.1.8886.1.18.2.1.1.1.2 |
This object specifies the connector type of the transceiver,
unknown, sc, db9, hssdc, bnc-tnc, fiber-coaxial-head, fiber-outlet,
lc, mt-rj, mu, sg, fiber-pigtail, mpo-parallel-optic , hssdcII,
copper, rj45.
this object belongs to xfp and sfp.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), sc(1), db9(2), hssdc(3), bnc-tnc(4), fiber-coaxial-head(5), fiber-jack(6), lc(7), mt-rj(8), mu(9), sg(10), fiber-pigtail(11), mpo-parallel-optic(12), hssdcII(20), copper(21), rj45(22) |
|
raisecomOpticalTransceiverDDMEntry |
1.3.6.1.4.1.8886.1.18.2.2.1.1 |
An entry in the raisecomOpticalTransceiverMonTable provides objects to
monitor an optical parameter at an optical interface.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RaisecomOpticalTransceiverDDMEntry |
|
|
raisecomOpticalTransceiverPMCurrentEntry |
1.3.6.1.4.1.8886.1.18.2.3.1.1 |
An entry in the raisecomOpticalTransceiverPMCurrentTable. It contains
performance monitoring data for a monitored optical
parameter at an interface, collected over the current 15
minute or the current 24 hour interval.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RaisecomOpticalTransceiverPMCurrentEntry |
|
|
raisecomOpticalTransceiverPMIntervalEntry |
1.3.6.1.4.1.8886.1.18.2.3.2.1 |
An entry in the raisecomOpticalTransceiverPMIntervalTable. It contains
performance monitoring data for an optical parameter,
collected over a previous interval.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RaisecomOpticalTransceiverPMIntervalEntry |
|
|
raisecomOpticalTransceiverCurrentStatusEntry |
1.3.6.1.4.1.8886.1.18.2.4.1.1 |
An entry in the raisecomOpticalTransceiverCurrentStatusTable. It contains
performance monitoring data for an optical parameter,
collected over a previous interval.
This object belongs to xfp/sfp.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RaisecomOpticalTransceiverCurrentStatusEntry |
|
|