RAD-BROADBAND-IF-MIB

File: RAD-BROADBAND-IF-MIB.mib (45597 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RAD-MIB
IF-MIB SNMP-FRAMEWORK-MIB

Imported symbols

OBJECT-TYPE Integer32 Gauge32
RowStatus TruthValue diverseIfWanGen
radAtm InterfaceIndex SnmpAdminString

Defined Types

PrtBdbandIndEntry  
SEQUENCE    
  prtBdbandCnfgIdx Integer32
  prtBdbandIdx Integer32
  prtBdbandIndSig INTEGER
  prtBdbandIndEvent INTEGER
  prtBdbandIndSigEnable INTEGER
  prtBdbandRowStatus RowStatus

PrtPhyConfigEntry  
SEQUENCE    
  prtPhyTimeElapsed Integer32
  prtPhyValidIntervals Integer32

PrtPhyCurrentEntry  
SEQUENCE    
  prtPhyCurrentLOS Gauge32
  prtPhyCurrentLSV Gauge32
  prtPhyCurrentUAS Gauge32
  prtPhyCurrentSES Gauge32
  prtPhyCurrentES Gauge32
  prtPhyCurrentStatus OCTET STRING
  prtPhyCurrentLOF Gauge32

PrtPhyIntervalEntry  
SEQUENCE    
  prtPhyIntervalNumber Integer32
  prtPhyIntervalLOS Gauge32
  prtPhyIntervalLSV Gauge32
  prtPhyIntervalUAS Gauge32
  prtPhyIntervalSES Gauge32
  prtPhyIntervalES Gauge32
  prtPhyIntervalStatus OCTET STRING
  prtPhyIntervalLOF Gauge32

R2CnfgEntry  
SEQUENCE    
  r2CnfgIdx Integer32
  r2CnfgProfileIdx Integer32
  r2Mode INTEGER
  r2Country Integer32
  r2Delay INTEGER
  r2MeteringInd INTEGER
  r2BreakMakeRatio INTEGER
  r2ReleaseGuardT2 Integer32
  r2Regret Integer32
  r2SeizeDetect Integer32
  r2SeizeAckDelay Integer32
  r2ClearBackDetect Integer32
  r2ClearFwdDetect Integer32
  r2FaultDetect Integer32
  r2FaultRemoveDetect Integer32
  r2MeterPulseDuration Integer32
  r2SeizeAckWait Integer32
  r2SeizeAckDetect Integer32
  r2AnswerDetect Integer32
  r2BlockRemoveDetect Integer32
  r2MeterPulseDetect Integer32
  r2ForcedDisconnect Integer32
  r2DisconnectAck Integer32
  r2ReleaseGuardT1 Integer32
  r2CnfgRowStatus RowStatus

R2TsEntry  
SEQUENCE    
  r2TsCnfgIdx Integer32
  r2TsProfileIdx Integer32
  r2TsIdx Integer32
  r2TsCallEnable INTEGER
  r2TsMetering INTEGER
  r2TsRowStatus RowStatus
  r2TsReversePolarity INTEGER

R2StatusEntry  
SEQUENCE    
  r2StatusSlotIdx INTEGER
  r2StatusPortIdx Integer32
  r2StatusTsIdx Integer32
  r2StatusSigDirection INTEGER
  r2StatusTsState INTEGER
  r2StatusProtocolState INTEGER

AtmLayer2XVclEntry  
SEQUENCE    
  atmLayer2XVclConnMode INTEGER
  atmLayer2XVclGroupIdx Integer32

AtmLayer2GroupEntry  
SEQUENCE    
  atmLayer2GroupIdx Integer32
  atmLayer2GroupRowStatus RowStatus
  atmLayer2GroupConnMode INTEGER
  atmLayer2GroupConnPriority OCTET STRING
  atmLayer2GroupName SnmpAdminString

AtmLayer2PriorityEntry  
SEQUENCE    
  atmLayer2PriorityGroupIdx Integer32
  atmLayer2PriorityRx Integer32
  atmLayer2PriorityIfIndex InterfaceIndex
  atmLayer2PriorityVclVpi Integer32
  atmLayer2PriorityVclVci Integer32

AtmLayer2CfgEntry  
SEQUENCE    
  atmLayer2CfgBridgingMode INTEGER
  atmLayer2CfgVlanMode INTEGER
  atmLayer2CfgAtmAcceptableFrameType INTEGER
  atmLayer2CfgAtmIngressFiltering TruthValue
  atmLayer2CfgAtmTxFrameType INTEGER
  atmLayer2CfgEthAcceptableFrameType INTEGER
  atmLayer2CfgBridgeAction INTEGER
  atmLayer2CfgLearningMode INTEGER
  atmLayer2CfgAgingTime Integer32

FrAtmIwfXConnectionEntry  
SEQUENCE    
  frAtmIwfXConnMode INTEGER
  frAtmIwfXConnSscsDlci Integer32

Defined Values

broadbandIf 1.3.6.1.4.1.164.3.1.6.8
OBJECT IDENTIFIER    

bdbandConfig 1.3.6.1.4.1.164.3.1.6.8.1
OBJECT IDENTIFIER    

prtPhyPerfHistory 1.3.6.1.4.1.164.3.1.6.8.2
OBJECT IDENTIFIER    

prtBdbandIndTable 1.3.6.1.4.1.164.3.1.6.8.1.1
The Indication Signal table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtBdbandIndEntry

prtBdbandIndEntry 1.3.6.1.4.1.164.3.1.6.8.1.1.1
An entry in the Indication Signal table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtBdbandIndEntry  

prtBdbandCnfgIdx 1.3.6.1.4.1.164.3.1.6.8.1.1.1.1
This object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtBdbandIdx 1.3.6.1.4.1.164.3.1.6.8.1.1.1.2
This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtBdbandIndSig 1.3.6.1.4.1.164.3.1.6.8.1.1.1.3
This object indicates a unique Indication Signal. ais(1) = AIS = Alarm Indication Signal. rdi(2) = RDI = Remote Defect Indication.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ais(1), rdi(2), aisAndRdi(3)  

prtBdbandIndEvent 1.3.6.1.4.1.164.3.1.6.8.1.1.1.4
This object indicates a unique Event that can cause the Indication Signal. slm(2) = SLM = Signal Label Mismatch eed(4) = EED = Excessive Error Defect pathTrace(5) = the end-to-end source/destination of information is wrong.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), slm(2), fail(3), eed(4), pathTrace(5)  

prtBdbandIndSigEnable 1.3.6.1.4.1.164.3.1.6.8.1.1.1.5
This object allows user to define if the event specified by prtBdbandIndEvent will cause creation of the Indication Signal specified by prtBdbandIndSig or not. disable - will not enable causing the signal enable - will enable causing the signal.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtBdbandRowStatus 1.3.6.1.4.1.164.3.1.6.8.1.1.1.6
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

prtPhyConfigTable 1.3.6.1.4.1.164.3.1.6.8.1.2
The Phy Config table. Used now for Phy25.6 Mbps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhyConfigEntry

prtPhyConfigEntry 1.3.6.1.4.1.164.3.1.6.8.1.2.1
An entry in the Phy Config table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtPhyConfigEntry  

prtPhyTimeElapsed 1.3.6.1.4.1.164.3.1.6.8.1.2.1.1
The number of seconds that have elapsed since the beginning of the current error-measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..899  

prtPhyValidIntervals 1.3.6.1.4.1.164.3.1.6.8.1.2.1.2
The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute since the interface has been online.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

prtPhyCurrentTable 1.3.6.1.4.1.164.3.1.6.8.2.1
The 25.6 Mbps Section/Line Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhyCurrentEntry

prtPhyCurrentEntry 1.3.6.1.4.1.164.3.1.6.8.2.1.1
An entry in the 25.6 Mbps Line Current table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtPhyCurrentEntry  

prtPhyCurrentLOS 1.3.6.1.4.1.164.3.1.6.8.2.1.1.1
The counter associated with the number of Loss Of Sync seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentLSV 1.3.6.1.4.1.164.3.1.6.8.2.1.1.2
The counter associated with the number of Line symbol violation seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentUAS 1.3.6.1.4.1.164.3.1.6.8.2.1.1.3
The counter associated with the number of UAS encountered by a 25.6 Mbps interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentSES 1.3.6.1.4.1.164.3.1.6.8.2.1.1.4
The counter associated with the number of SES encountered by a 25.6 Mbps interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentES 1.3.6.1.4.1.164.3.1.6.8.2.1.1.5
The number of Errored Seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentStatus 1.3.6.1.4.1.164.3.1.6.8.2.1.1.6
The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

prtPhyCurrentLOF 1.3.6.1.4.1.164.3.1.6.8.2.1.1.7
The number of Loss of Frames, encountered by an interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalTable 1.3.6.1.4.1.164.3.1.6.8.2.2
The Line Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhyIntervalEntry

prtPhyIntervalEntry 1.3.6.1.4.1.164.3.1.6.8.2.2.1
An entry in the 25.6 Mbps Line Interval table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtPhyIntervalEntry  

prtPhyIntervalNumber 1.3.6.1.4.1.164.3.1.6.8.2.2.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

prtPhyIntervalLOS 1.3.6.1.4.1.164.3.1.6.8.2.2.1.2
The counter associated with the number of Loss Of Sync seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalLSV 1.3.6.1.4.1.164.3.1.6.8.2.2.1.3
The counter associated with the number of line symbol violation seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalUAS 1.3.6.1.4.1.164.3.1.6.8.2.2.1.4
The counter associated with the number of UAS encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalSES 1.3.6.1.4.1.164.3.1.6.8.2.2.1.5
The counter associated with the number of SES encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalES 1.3.6.1.4.1.164.3.1.6.8.2.2.1.6
The number of Errored Seconds, encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalStatus 1.3.6.1.4.1.164.3.1.6.8.2.2.1.7
The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

prtPhyIntervalLOF 1.3.6.1.4.1.164.3.1.6.8.2.2.1.8
The number of Loss of Frames, encountered by an interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

r2If 1.3.6.1.4.1.164.3.1.6.9
OBJECT IDENTIFIER    

r2ProfileCnfg 1.3.6.1.4.1.164.3.1.6.9.1
OBJECT IDENTIFIER    

r2IfStatus 1.3.6.1.4.1.164.3.1.6.9.2
OBJECT IDENTIFIER    

r2CnfgTable 1.3.6.1.4.1.164.3.1.6.9.1.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    R2CnfgEntry

r2CnfgEntry 1.3.6.1.4.1.164.3.1.6.9.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  R2CnfgEntry  

r2CnfgIdx 1.3.6.1.4.1.164.3.1.6.9.1.1.1.1
This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. Write is allowed only to TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

r2CnfgProfileIdx 1.3.6.1.4.1.164.3.1.6.9.1.1.1.2
Profile Index. Valid values: 1..5 Only instances of profiles that are defined having agnSigProfType=r2Cas will exist in this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

r2Mode 1.3.6.1.4.1.164.3.1.6.9.1.1.1.3
R2 Mode. auto - in this mode, default value of timers will be used by R2, according to the selected r2Country. manual - in this mode, user can change the value of R2 timers within the valid limits, specific to each country.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER auto(2), manual(3)  

r2Country 1.3.6.1.4.1.164.3.1.6.9.1.1.1.4
R2 Country. R2 Timers can have different range of values and defaults for each country. When r2Mode=auto, the default value is used by R2 according to this selected country. 1=ITU-T (standard values) 2=Korea 3=India 4=Brasil (continuous) 5=Brasil (pulsed) 6..10 - reserved for future countries.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2Delay 1.3.6.1.4.1.164.3.1.6.9.1.1.1.5
This object enables user to configure the link as satellite or terrestrial. The seize acknowledge detect timing is much shorter (msec) for terrestrial link than for satellite link (1-2 sec).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), terrestrial(2), satellite(3)  

r2MeteringInd 1.3.6.1.4.1.164.3.1.6.9.1.1.1.6
Which Bit will be used for Metering Indication.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), cBit(2), bBit(3)  

r2BreakMakeRatio 1.3.6.1.4.1.164.3.1.6.9.1.1.1.7
This object describes the Break-Make Ratio of Pulse Duration, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), break56Make44(2), break64Make36(3), break80Make20(4)  

r2ReleaseGuardT2 1.3.6.1.4.1.164.3.1.6.9.1.1.1.8
Release Guard timing T2. Release guard timing before going to idle, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2Regret 1.3.6.1.4.1.164.3.1.6.9.1.1.1.9
Regret duration, in [sec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2SeizeDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.10
Seize Detect. Timer of the R2 incoming side. Minimum duration to detect a valid seizure, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2SeizeAckDelay 1.3.6.1.4.1.164.3.1.6.9.1.1.1.11
Timer of the R2 incoming side. Delay before sending a valid seize ack signal, in [msec]. Applicable only when r2Mode=manual. only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2ClearBackDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.12
Timer of the R2 incoming side. Minimum duration to recognize a valid clear-back, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2ClearFwdDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.13
Timer of the R2 incoming side. Minimum duration to recognize a valid clear-forward, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2FaultDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.14
Timer of the R2 incoming side. Minimum duration to recognize a block signal, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2FaultRemoveDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.15
Timer of the R2 incoming side. Minimum duration to recognize a valid block removal signal, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2MeterPulseDuration 1.3.6.1.4.1.164.3.1.6.9.1.1.1.16
Timer of the R2 incoming side. Duration of metering pulse to be sent, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2SeizeAckWait 1.3.6.1.4.1.164.3.1.6.9.1.1.1.17
Timer of the R2 outgoing side. Minimum duration to receive seizure acknowledge signal, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2SeizeAckDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.18
Timer of the R2 outgoing side. Minimum duration to recognize a valid seizure acknowledge signal, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2AnswerDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.19
Timer of the R2 outgoing side. Minimum duration to recognize a valid answer signal, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2BlockRemoveDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.20
Timer of the R2 outgoing side. Minimum duration to recognize a valid block removal signal, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2MeterPulseDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.21
Timer of the R2 outgoing side. Minimum duration of incoming meter pulse, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2ForcedDisconnect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.22
Timer of the R2 outgoing side. Minimum duration to recognize disconnect signal, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2DisconnectAck 1.3.6.1.4.1.164.3.1.6.9.1.1.1.23
Timer of the R2 outgoing side. Minimum duration to recognize disconnect acknowledge signal, in [msec]. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2ReleaseGuardT1 1.3.6.1.4.1.164.3.1.6.9.1.1.1.24
Timer of the R2 outgoing side. Minimum duration to release guard, in [msec]. During this time, no new call can be initiated. RW only when r2Mode=manual.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

r2CnfgRowStatus 1.3.6.1.4.1.164.3.1.6.9.1.1.1.25
This object enables the user to add/delete entries to/from the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

r2TsTable 1.3.6.1.4.1.164.3.1.6.9.1.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    R2TsEntry

r2TsEntry 1.3.6.1.4.1.164.3.1.6.9.1.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  R2TsEntry  

r2TsCnfgIdx 1.3.6.1.4.1.164.3.1.6.9.1.2.1.1
This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. Write is allowed only to TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

r2TsProfileIdx 1.3.6.1.4.1.164.3.1.6.9.1.2.1.2
Profile Index. Valid values: 1..5 Only instances of profiles that are defined having agnSigProfType=r2Cas will exist in this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

r2TsIdx 1.3.6.1.4.1.164.3.1.6.9.1.2.1.3
TS Index. Valid values: 1..31
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

r2TsCallEnable 1.3.6.1.4.1.164.3.1.6.9.1.2.1.4
This object indicates the Enabled Call direction for the specific TS.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER incoming(2), outgoing(3), both(4)  

r2TsMetering 1.3.6.1.4.1.164.3.1.6.9.1.2.1.5
This object indicates if the specific TS should support Metering.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

r2TsRowStatus 1.3.6.1.4.1.164.3.1.6.9.1.2.1.6
This object enables the user to add/delete entries to/from the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

r2TsReversePolarity 1.3.6.1.4.1.164.3.1.6.9.1.2.1.7
This object indicates if the specific TS should support Reverse Polarity.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

r2StatusTable 1.3.6.1.4.1.164.3.1.6.9.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    R2StatusEntry

r2StatusEntry 1.3.6.1.4.1.164.3.1.6.9.2.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  R2StatusEntry  

r2StatusSlotIdx 1.3.6.1.4.1.164.3.1.6.9.2.1.1.1
Slot Index
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

r2StatusPortIdx 1.3.6.1.4.1.164.3.1.6.9.2.1.1.2
This object indicates a unique port number of the ML having R2 interface. Valid values: exPrt1 (1)..exPrt4 (4)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

r2StatusTsIdx 1.3.6.1.4.1.164.3.1.6.9.2.1.1.3
Time Slot index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..31  

r2StatusSigDirection 1.3.6.1.4.1.164.3.1.6.9.2.1.1.4
R2 Time Slot Signaling Direction.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), incoming(2), outgoing(3)  

r2StatusTsState 1.3.6.1.4.1.164.3.1.6.9.2.1.1.5
R2 TS State
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notUsed(1), normal(2), remoteBlocked(3), localBlocked(4), localLoop(5), remoteLoop(6)  

r2StatusProtocolState 1.3.6.1.4.1.164.3.1.6.9.2.1.1.6
R2 Protocol State.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), seized(2), seizureAcknowledged(3), answered(4), clearForward(5), clearBack(6), blocked(7), forcedDisc(8), doubleSeizure(9), fault(10), discAcknowledged(11), fault1(12), fault6(13), fault3(14)  

atmLayer2 1.3.6.1.4.1.164.12.7
OBJECT IDENTIFIER    

atmLayer2XVclTable 1.3.6.1.4.1.164.12.7.1
This table is an extension of VCL table, which is created for each LAN VCC.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLayer2XVclEntry

atmLayer2XVclEntry 1.3.6.1.4.1.164.12.7.1.1
Conceptual row in atmVclTable. This table augments the RFC2515 VCL table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLayer2XVclEntry  

atmLayer2XVclConnMode 1.3.6.1.4.1.164.12.7.1.1.1
Each valid LAN VCC is either Main or Sub. This parameter is configured only once on creation of a LAN VCC. It can not be changed after creation. In order to change the Mode, user should delete the connection and create a new one. main - A LAN VCC, which holds its own bridge port. Bridge forwarding and Bridge learning is performed only on Main VCCs. For working on a transparent bridge, that doesn't perform layer 2 priority mapping, a Main VCC should be opened, which is the default connection Mode. When working with layer 2 priority, a group of LAN VCCs should be configured, where each group will be associated with only one Main VCC. A specific Main can not be used by more than one group. sub - A LAN VCC is not part of the bridging mechanism. A Sub VCC automatically inherit some general definitions from Main VCC of its group: ATM Slot/Port and LAN Slot/Port. Max number of Sub VCCs allowed per group is: [Number of Priorities - 1].
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER main(1), sub(2)  

atmLayer2XVclGroupIdx 1.3.6.1.4.1.164.12.7.1.1.2
The group identifier. A VCC Group identifier = 0 if the VCC was not associated with a group yet. This value is updated according to the group identifier set by atmLayer2GroupTable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLayer2GroupTable 1.3.6.1.4.1.164.12.7.2
This table contains groups and their members. A group is a bundle of VCCs, which acts as different queues. Main and Sub VCCs should have the same ATM slot and port, and the same LAN slot and port. Each group contains: 1 to VCCs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLayer2GroupEntry

atmLayer2GroupEntry 1.3.6.1.4.1.164.12.7.2.1
Conceptual row in atmLayer2GroupTable. The indexes: ifIndex, atmVclVpi and atmVclVci indicate the Network ATM End-Point. Upon a group creation, one Main VCC must be added first. After the group was created, Sub VCCs may be added to the group.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLayer2GroupEntry  

atmLayer2GroupIdx 1.3.6.1.4.1.164.12.7.2.1.1
The group identifier. 0 is not a valid index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLayer2GroupRowStatus 1.3.6.1.4.1.164.12.7.2.1.2
Creation/Deletion of rows in the table, and indication of the entry's status.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmLayer2GroupConnMode 1.3.6.1.4.1.164.12.7.2.1.3
Each valid LAN VCC is either Main or Sub as configured in atmLayer2XVclTable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER main(1), sub(2)  

atmLayer2GroupConnPriority 1.3.6.1.4.1.164.12.7.2.1.4
This parameter is configured by atmLayer2PriorityRx from atmLayer2PriorityTable. Each bit in the Octet represents a specific priority as follows: MSB 7 6 5 4 3 2 1 0 LSB -> Priorities |--------------------| 1 0 0 1 0 0 0 1 -> Value In this example, a certain VCC has several priorities: 0, 4 and 7.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

atmLayer2GroupName 1.3.6.1.4.1.164.12.7.2.1.5
Group name. Configured by the user. The name is unique per system. For atmLayer2GroupIdx=0, the name will be null.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

atmLayer2PriorityTable 1.3.6.1.4.1.164.12.7.3
This table maps all priorities inside a group. Several priorities might be mapped to the same VCC. Upon priority change, the agent will update the VCCs of the changed priority in this table, and will update - atmLayer2GroupConnPriority parameter of both former and new owners of the changed priority. Changing a VCC value is actually a change of three parameters simultaneously: atmLayer2PriorityIfIndex, atmLayer2PriorityVclVpi and atmLayer2PriorityVclVci. Otherwise, the set will be rejected, since there might be that such VCC doesn't exist in the specific group.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLayer2PriorityEntry

atmLayer2PriorityEntry 1.3.6.1.4.1.164.12.7.3.1
Conceptual row in atmLayer2PriorityTable. Each entry is a Network ATM End-Point per priority. Upon a group creation, all priorities are mapped to the Main VCC. Number of entries per group is according to the number of priorities enabled. (For example, for Max priorities = 8, the agent will create 8 entries).
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLayer2PriorityEntry  

atmLayer2PriorityGroupIdx 1.3.6.1.4.1.164.12.7.3.1.1
The group identifier.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLayer2PriorityRx 1.3.6.1.4.1.164.12.7.3.1.2
The priority values. The used values are 0-7, but since this value is part of the index of the table, and in order to avoid '0' as an index, the index syntax is 1..8, but the real value is atmLayer2PriorityRx-1: 0 - for Low priority. 7 - for High priority.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..8  

atmLayer2PriorityIfIndex 1.3.6.1.4.1.164.12.7.3.1.3
ATM ifIndex of the network End-Point.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndex  

atmLayer2PriorityVclVpi 1.3.6.1.4.1.164.12.7.3.1.4
Vpi of the network End-Point.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmLayer2PriorityVclVci 1.3.6.1.4.1.164.12.7.3.1.5
Vci of the network End-Point.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmLayer2GroupIndexNext 1.3.6.1.4.1.164.12.7.4
This object contains an appropriate value to be used for atmLayer2GroupIdx when creating entries in the atmLayer2GroupTable. The value 0 indicates that no unassigned entries are available. To obtain the atmLayer2GroupIdx value for a new entry, the manager gets the current value of this object. The next index will be of the first unassigned entry. It will be provided by checking the assigned entries.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

atmLayer2CfgTable 1.3.6.1.4.1.164.12.7.5
Bridge configuration Table. This table supports multi-bridge and bridge features within an ATM device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLayer2CfgEntry

atmLayer2CfgEntry 1.3.6.1.4.1.164.12.7.5.1
Conceptual row in atmLayer2CfgTable. Each entry in this table contains the bridging attributes for both Ethernet and ATM sides. The interface index is the Ethernet port interface. For Ace52: this object represents the Bridge ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLayer2CfgEntry  

atmLayer2CfgBridgingMode 1.3.6.1.4.1.164.12.7.5.1.1
Bridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER accessOnly(1), accessAndSwitching(2)  

atmLayer2CfgVlanMode 1.3.6.1.4.1.164.12.7.5.1.2
VLAN Mode. Upon Mode changing, all LAN VCCs will be deleted by the agent from all tables that include LAN VCCs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

atmLayer2CfgAtmAcceptableFrameType 1.3.6.1.4.1.164.12.7.5.1.3
The Frame Type that will be acceptable by the VCCs that are associated with this Ethernet port. Frames which don't match the selected type will be discarded. admitAll - all frames will be accepted. admitOnlyVlanTagged - only Tagged frames will be accepted. admitOnlyUnTagged - only unTagged frames will be accepted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), admitAll(2), admitOnlyVlanTagged(3), admitOnlyUnTagged(4)  

atmLayer2CfgAtmIngressFiltering 1.3.6.1.4.1.164.12.7.5.1.4
For the VCCs that are associated with this Ethernet port, when this is true(1) the device will discard incoming frames for VLANs which do not include this Port in its Member set. When false(2), the port will accept all incoming frames.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

atmLayer2CfgAtmTxFrameType 1.3.6.1.4.1.164.12.7.5.1.5
The Frame Type that will be transmitted by the VCCs that are associated with this Ethernet port. unTagged - The transmitted frames will be unTagged. tagged - The transmitted frames will be Tagged.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unTagged(2), tagged(3)  

atmLayer2CfgEthAcceptableFrameType 1.3.6.1.4.1.164.12.7.5.1.6
The Frame Type that this Ethernet port will accept. (for ACE-52: the Frame Type that this Bridge will accept) This parameter is notApplicable for atmLayer2VlanMode=disable. Frames which don't match the selected type will be discarded. admitAll - all frames will be accepted. admitOnlyVlanTagged - only Tagged frames will be accepted. admitOnlyUnTagged - only unTagged frames will be accepted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), admitAll(2), admitOnlyVlanTagged(3), admitOnlyUnTagged(4)  

atmLayer2CfgBridgeAction 1.3.6.1.4.1.164.12.7.5.1.7
This object enables to perform the specified action on the selected port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER deleteLanTable(7), noOp(255)  

atmLayer2CfgLearningMode 1.3.6.1.4.1.164.12.7.5.1.8
This object specifies the mode of the learning process of a bridge. svl - Shared VLAN process. If an individual MAC Address is learned in one VLAN, this information is used in forwarding decisions taken for that address for all other VLANs. ivl - Independent VLAN process. If an individual MAC Address is learned in one VLAN, this information is not used in forwarding decisions taken for that address for all other VLANs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER svl(1), ivl(2)  

atmLayer2CfgAgingTime 1.3.6.1.4.1.164.12.7.5.1.9
The timeout period in seconds for aging out dynamically learned forwarding information.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radAtmFr 1.3.6.1.4.1.164.12.8
OBJECT IDENTIFIER    

frAtmIwfXConnectionTable 1.3.6.1.4.1.164.12.8.1
This table is an extension of frAtmIwfXConnectionTable from RFC2955.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrAtmIwfXConnectionEntry

frAtmIwfXConnectionEntry 1.3.6.1.4.1.164.12.8.1.1
Conceptual row in frAtmIwfXConnectionTable. This table augments the RFC2955.
Status: current Access: not-accessible
OBJECT-TYPE    
  FrAtmIwfXConnectionEntry  

frAtmIwfXConnMode 1.3.6.1.4.1.164.12.8.1.1.1
FR IWF Mode. service - Service InterWorking (FRF.8), network - Network InterWorking (FRF.5).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER service(1), network(2)  

frAtmIwfXConnSscsDlci 1.3.6.1.4.1.164.12.8.1.1.2
This parameter is relevant for frAtmIwfXConnMode=network (FRF.5) only. This parameter allow configuration of the FR SSCS DLCI that is transferred to the remote FR unit.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32