PRVT-SWITCH-MIB

File: PRVT-SWITCH-MIB.mib (54349 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
PRIV-VENDORDEF-MIB IF-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Integer32 NOTIFICATION-TYPE TEXTUAL-CONVENTION
DisplayString TruthValue NOTIFICATION-GROUP
privateVendorOID ifIndex ifAdminStatus
ifOperStatus

Defined Types

UnitIndex  
This value represents the physical position of the unit inside the stack.
TEXTUAL-CONVENTION    
  INTEGER master(1), slave1(2), slave2(3), slave3(4), slave4(5)  

ModuleHwType  
This value represents the physical type of the port or module.
TEXTUAL-CONVENTION    
  INTEGER uninstalled(1), stacking(2), m100BaseTx(3), m100BaseFxVF45(4), m1000BaseSxSCMM850(6), m1000BaseLxSC1300(7), m1000BaseSCSMLDA(8), m1000BaseSCSMLDB(9), m1000BaseSxVF45MM850(10), m1000BaseLxVF451300(11), m1000BaseSxMTRJMM(12), m1000BaseLxMTRJ1300(13), m10BaseFlVF45(14), m10BaseFlVF45X4Ports(15), m100BaseFxSCMM(16), m100BaseFxSCSM(17), m100BaseFxSCSM2Port(18), m100BaseFxSCSMLD(19), m100BaseFxSCSMLD2Port(20), m100BaseFxMTRJMM(21), m100BaseFxMTRJSM(22), mDUAL-SFP(23), mDUAL-SFP-installed(24), m1000BaseTx(25), m1000BaseCx(26), mVDSLNT(30), mVDSLLT(31), mVDSLNTand100BaseTX(32), mVDSLLTand100BaseTX(33), mVDSLLT24Port(34), mLayer31000BaseSXSCMM(35), mLayer31000BaseLXSCSM(36), mLayer31000BaseSXSFFMM(37), mLayer31000BaseLXSFFSM(38), mLayer3100BaseFXSCMM2Port(39), mLayer3100BaseFXSCSM2Port(40), mLayer3100BaseFXSCMM4Port(41), mLayer3100BaseFXSCSM4Port(42), mLayer3100BaseFXSFFMM(43), mLayer3100BaseFXSFFSM(44), mLayer3100BaseTX(45), m1000BaseGBIC-installed(46), m1000BaseGBIC-not-installed(47), mLayer31000BaseSX-GIBIC(48), mLayer31000BaseLX-GIBIC(49), mLayer31000BaseCX-GIBIC(50), mLayer31000BaseT-GIBIC(51), mLayer3100BaseSMLCL-GIBIC(52), mLayer3100BaseM5o6SNI-GIBIC(53), mLayer31000BasePOSMM(54), mLayer31000BasePOSSM(55), mLayer3100BaseFXSFFMM20Port(56), mLayer3100BaseFXSFFSM20Port(57), mLayer3100BaseFXSFFMM5Port(58), mLayer3100BaseFXSFFSM5Port(59), mDS3ATM(60), mDS1MLP(61), mMLPmother(62), m1000BaseSFP-installed(63), mLayer31000BaseSX-SFP(65), mLayer31000BaseLX-SFP(66), mLayer31000BaseCX-SFP(67), mLayer31000BaseT-SFP(68), mLayer3100BaseSMLCL-SFP(69), mLayer3100BaseM5o6SNI-SFP(70), m100BaseGBIC-not-installed(71), mLayer310GBaseSR-XFP(72), mLayer310GBaseLR-XFP(73), mLayer310GBaseER-XFP(74), mLayer310GBaseSW-XFP(75), mLayer310GBaseLW-XFP(76), mLayer310GBaseEW-XFP(77), mLayer310GBase-XFP(78), m10000BaseMEDIA-not-installed(79), mCpmCard(80), mLayer310GBaseLRW-XFP(81), mLayer310GBaseERW-XFP(82), mLayer31000BaseX-SFP(83), mCES(84), mLayer3100BaseFX-SFP(85), mCES-4TDM(86), mLayer31000BaseLX-BD-SFP(87), mMiRIC-E1(88), mMiRIC-E3(89), mMiRIC-T1(90), mMiRIC-T3(91), mLayer31000BaseSFP-Unknown(92), m10000BaseXFP-Unknown(93), xAUI-1G-10G(94), mLayer3-10-1000BaseT(95), mLayer310GBaseSMSR-XFP(96), mLayer310GBaseSMLR-XFP(97), mLayer310GBaseSMER-XFP(98), mLayer310GBaseSMSW-XFP(99), mLayer310GBaseSMLW-XFP(101), mLayer310GBaseSMEW-XFP(102), mLayer310GBaseSMSRW-XFP(103), mLayer310GBaseSMLRW-XFP(104), mLayer310GBaseSMERW-XFP(105), mLayer310GBaseCpPgt-XFP(106), mLayer310GBaseSMZR-XFP(107), mLayer31000BaseZX-SFP(108), mLayer310GBaseSMZX-XFP(109), mLayer310GBaseSMEX-XFP(110), mLayer31000BaseT-WithoutAN-SFP(111), mLayer3100BaseLX-BD-SFP(112)  

Series  
This value represents the series of the switch.
TEXTUAL-CONVENTION    
  INTEGER notExist(1), e-series(2), g-series(3), t-series(4)  

SysIntfEntry  
SEQUENCE    
  sysStackNo UnitIndex
  sysSlotNo Integer32
  sysIntfUnitExist INTEGER
  sysIntfModule ModuleHwType

ConfigL2IfaceEntry  
SEQUENCE    
  configL2IfaceUnit Integer32
  configL2IfaceSlot Integer32
  configL2IfacePort Integer32
  configL2IfaceName DisplayString
  configL2IfaceEnable INTEGER
  configL2IfaceSTPEnable INTEGER
  configL2IfaceDuplexSpeedSet INTEGER
  configL2IfaceFlow INTEGER
  configL2IfaceBackpressure INTEGER
  configL2IfaceResetCounters INTEGER
  configL2IfaceDefaultVID Integer32
  configL2IfaceSnifferIfIndex Integer32
  configL2TopologyChangeDetection TruthValue
  configL2IfaceDuplexModeSet INTEGER
  configL2IfaceSpeedSet INTEGER
  configL2IfaceBroadcastRateLimit Integer32
  configL2IfaceMulticastRateLimit Integer32
  configL2IfaceUnknownRateLimit Integer32
  configL2IfaceBroadcastBurstSize Integer32
  configL2IfaceMulticastBurstSize Integer32
  configL2IfaceUnknownBurstSize Integer32
  configL2IfaceMtu Integer32
  configL2IfaceAdminCrossOver INTEGER
  configL2IfaceRemoteFaultDetect INTEGER

ReportsL2IfaceEntry  
SEQUENCE    
  reportsL2IfaceUnit Integer32
  reportsL2IfaceSlot Integer32
  reportsL2IfacePort Integer32
  reportsL2IfaceBridgeIndex Integer32
  reportsL2IfaceType INTEGER
  reportsL2IfaceLink INTEGER
  reportsL2IfaceDuplexSpeedGet INTEGER
  reportsL2IfaceTXOctetsNoErr Counter32
  reportsL2IfaceTXPacketsNoErr Counter32
  reportsL2IfaceRXOctetsNoErr Counter32
  reportsL2IfaceRXPacketsNoErr Counter32
  reportsL2IfaceIfInOctets Counter32
  reportsL2IfaceIfInUcastPkts Counter32
  reportsL2IfaceIfInNUcastPkts Counter32
  reportsL2IfaceIfInDiscards Counter32
  reportsL2IfaceIfInErrors Counter32
  reportsL2IfaceIfInUnknownProtos Counter32
  reportsL2IfaceIfOutOctets Counter32
  reportsL2IfaceIfOutUcastPkts Counter32
  reportsL2IfaceIfOutNUcastPkts Counter32
  reportsL2IfaceIfOutDiscards Counter32
  reportsL2IfaceIfOutErrors Counter32
  reportsL2IfaceStatsDropEvents Counter32
  reportsL2IfaceStatsOctets Counter32
  reportsL2IfaceStatsPkts Counter32
  reportsL2IfaceStatsBroadcastPkts Counter32
  reportsL2IfaceStatsMulticastPkts Counter32
  reportsL2IfaceStatsCRCAlignErrors Counter32
  reportsL2IfaceStatsUndersizePkts Counter32
  reportsL2IfaceStatsOversizePkts Counter32
  reportsL2IfaceStatsFragments Counter32
  reportsL2IfaceStatsJabbers Counter32
  reportsL2IfaceStatsCollisions Counter32
  reportsL2IfaceStatsPkts64Octets Counter32
  reportsL2IfaceStatsPkts65to127Octets Counter32
  reportsL2IfaceStatsPkts128to255Octets Counter32
  reportsL2IfaceStatsPkts256to511Octets Counter32
  reportsL2IfaceStatsPkts512to1023Octets Counter32
  reportsL2IfaceStatsPkts1024to1518Octets Counter32
  reportsL2IfaceFlow INTEGER
  reportsL2IfaceHWType ModuleHwType
  reportsL2IfaceActiveJackIndex Integer32

ReportsIfJackEntry  
SEQUENCE    
  reportsIfJackIndex Integer32
  reportsIfJackType ModuleHwType

Defined Values

prvtSwitchMib 1.3.6.1.4.1.738.1.5.100
The switch MIB module for managing switch parameters
MODULE-IDENTITY    

prvt-products 1.3.6.1.4.1.738.1
OBJECT IDENTIFIER    

prvt-mgmt 1.3.6.1.4.1.738.2
OBJECT IDENTIFIER    

rptr 1.3.6.1.4.1.738.1.1
OBJECT IDENTIFIER    

bridge 1.3.6.1.4.1.738.1.2
OBJECT IDENTIFIER    

trclam 1.3.6.1.4.1.738.1.3
OBJECT IDENTIFIER    

router 1.3.6.1.4.1.738.1.4
OBJECT IDENTIFIER    

switch 1.3.6.1.4.1.738.1.5
OBJECT IDENTIFIER    

ipSwitch 1.3.6.1.4.1.738.1.6
OBJECT IDENTIFIER    

bsw 1.3.6.1.4.1.738.1.5.1
OBJECT IDENTIFIER    

tps 1.3.6.1.4.1.738.1.5.2
OBJECT IDENTIFIER    

tpf 1.3.6.1.4.1.738.1.5.3
OBJECT IDENTIFIER    

titan 1.3.6.1.4.1.738.1.5.5
OBJECT IDENTIFIER    

titant5 1.3.6.1.4.1.738.1.5.7
OBJECT IDENTIFIER    

edgeLinkT4 1.3.6.1.4.1.738.1.5.15
OBJECT IDENTIFIER    

edgeLinkT5 1.3.6.1.4.1.738.1.5.17
OBJECT IDENTIFIER    

titanPro 1.3.6.1.4.1.738.1.5.20
OBJECT IDENTIFIER    

acs25L4282 1.3.6.1.4.1.738.1.5.500
OBJECT IDENTIFIER    

acs25L4282t5 1.3.6.1.4.1.738.1.5.502
OBJECT IDENTIFIER    

vol0215 1.3.6.1.4.1.738.1.5.999
OBJECT IDENTIFIER    

vol4000 1.3.6.1.4.1.738.1.5.998
OBJECT IDENTIFIER    

vol5000 1.3.6.1.4.1.738.1.5.996
OBJECT IDENTIFIER    

prvtSwitchNotifications 1.3.6.1.4.1.738.1.5.100.0
OBJECT IDENTIFIER    

sys 1.3.6.1.4.1.738.1.5.100.1
OBJECT IDENTIFIER    

config 1.3.6.1.4.1.738.1.5.100.2
OBJECT IDENTIFIER    

reports 1.3.6.1.4.1.738.1.5.100.3
OBJECT IDENTIFIER    

test 1.3.6.1.4.1.738.1.5.100.4
OBJECT IDENTIFIER    

commands 1.3.6.1.4.1.738.1.5.100.5
OBJECT IDENTIFIER    

prvtSwitchConformance 1.3.6.1.4.1.738.1.5.100.6
OBJECT IDENTIFIER    

sysProductsOids 1.3.6.1.4.1.738.1.5.100.1.1
OBJECT IDENTIFIER    

sysIntf 1.3.6.1.4.1.738.1.5.100.1.2
OBJECT IDENTIFIER    

sysManufacturing 1.3.6.1.4.1.738.1.5.100.1.3
OBJECT IDENTIFIER    

sysSwitchingHW 1.3.6.1.4.1.738.1.5.100.1.4
OBJECT IDENTIFIER    

t4Router 1.3.6.1.4.1.738.1.5.100.1.1.1
OBJECT IDENTIFIER    

t5Router 1.3.6.1.4.1.738.1.5.100.1.1.2
OBJECT IDENTIFIER    

t5ProRouter 1.3.6.1.4.1.738.1.5.100.1.1.3
OBJECT IDENTIFIER    

t6Router 1.3.6.1.4.1.738.1.5.100.1.1.4
OBJECT IDENTIFIER    

t5c-48TRouter 1.3.6.1.4.1.738.1.5.100.1.1.5
OBJECT IDENTIFIER    

t5RNRouter 1.3.6.1.4.1.738.1.5.100.1.1.6
OBJECT IDENTIFIER    

t5c-24TRouter 1.3.6.1.4.1.738.1.5.100.1.1.7
OBJECT IDENTIFIER    

t5c-24MRouter 1.3.6.1.4.1.738.1.5.100.1.1.8
OBJECT IDENTIFIER    

t5c-24FRouter 1.3.6.1.4.1.738.1.5.100.1.1.9
OBJECT IDENTIFIER    

t5c-24GRouter 1.3.6.1.4.1.738.1.5.100.1.1.10
OBJECT IDENTIFIER    

t5c-24GTRouter 1.3.6.1.4.1.738.1.5.100.1.1.11
OBJECT IDENTIFIER    

t6pro-lc-20G 1.3.6.1.4.1.738.1.5.100.1.1.13
OBJECT IDENTIFIER    

t6pro-cpm 1.3.6.1.4.1.738.1.5.100.1.1.14
OBJECT IDENTIFIER    

tMetro 1.3.6.1.4.1.738.1.5.100.1.1.16
OBJECT IDENTIFIER    

tMarc 1.3.6.1.4.1.738.1.5.100.1.1.17
OBJECT IDENTIFIER    

aHUB1-A 1.3.6.1.4.1.738.1.5.100.1.1.18
OBJECT IDENTIFIER    

tMetro-ES 1.3.6.1.4.1.738.1.5.100.1.1.19
OBJECT IDENTIFIER    

tMarc-E 1.3.6.1.4.1.738.1.5.100.1.1.20
OBJECT IDENTIFIER    

tMarc-EW 1.3.6.1.4.1.738.1.5.100.1.1.21
OBJECT IDENTIFIER    

tMarc-WDB 1.3.6.1.4.1.738.1.5.100.1.1.22
OBJECT IDENTIFIER    

tMarc-WD 1.3.6.1.4.1.738.1.5.100.1.1.23
OBJECT IDENTIFIER    

tMarc-F 1.3.6.1.4.1.738.1.5.100.1.1.24
OBJECT IDENTIFIER    

t5c-XG 1.3.6.1.4.1.738.1.5.100.1.1.27
OBJECT IDENTIFIER    

compact 1.3.6.1.4.1.738.1.5.100.1.1.14.1
OBJECT IDENTIFIER    

classic 1.3.6.1.4.1.738.1.5.100.1.1.14.2
OBJECT IDENTIFIER    

as9205 1.3.6.1.4.1.738.1.5.100.1.1.7.1
OBJECT IDENTIFIER    

as9205-F 1.3.6.1.4.1.738.1.5.100.1.1.9.1
OBJECT IDENTIFIER    

tMarc-250 1.3.6.1.4.1.738.1.5.100.1.1.17.1
OBJECT IDENTIFIER    

tMarc-254 1.3.6.1.4.1.738.1.5.100.1.1.17.2
OBJECT IDENTIFIER    

tMarc-254h 1.3.6.1.4.1.738.1.5.100.1.1.17.3
OBJECT IDENTIFIER    

tMarc-340 1.3.6.1.4.1.738.1.5.100.1.1.17.10
OBJECT IDENTIFIER    

tMarc-380 1.3.6.1.4.1.738.1.5.100.1.1.17.11
OBJECT IDENTIFIER    

tMarc-340-E 1.3.6.1.4.1.738.1.5.100.1.1.20.1
OBJECT IDENTIFIER    

tMarc-380-E 1.3.6.1.4.1.738.1.5.100.1.1.20.2
OBJECT IDENTIFIER    

tMarc-340-EW 1.3.6.1.4.1.738.1.5.100.1.1.21.1
OBJECT IDENTIFIER    

tMarc-380-EW 1.3.6.1.4.1.738.1.5.100.1.1.21.2
OBJECT IDENTIFIER    

tMarc-340WD-B 1.3.6.1.4.1.738.1.5.100.1.1.22.1
OBJECT IDENTIFIER    

tMarc-340WD 1.3.6.1.4.1.738.1.5.100.1.1.23.1
OBJECT IDENTIFIER    

tMarc-340-F 1.3.6.1.4.1.738.1.5.100.1.1.24.1
OBJECT IDENTIFIER    

tMarc-280 1.3.6.1.4.1.738.1.5.100.1.1.17.20
OBJECT IDENTIFIER    

dm9225 1.3.6.1.4.1.738.1.5.100.1.1.17.1.1
OBJECT IDENTIFIER    

dm9225-E 1.3.6.1.4.1.738.1.5.100.1.1.17.2.1
OBJECT IDENTIFIER    

dm9234 1.3.6.1.4.1.738.1.5.100.1.1.17.10.1
OBJECT IDENTIFIER    

alcatel-7250 1.3.6.1.4.1.738.1.5.100.1.1.16.1
OBJECT IDENTIFIER    

alcatel-7250-ES 1.3.6.1.4.1.738.1.5.100.1.1.19.1
OBJECT IDENTIFIER    

alcatel-7250-ESA 1.3.6.1.4.1.738.1.5.100.1.1.19.2
OBJECT IDENTIFIER    

tMetro-ESA 1.3.6.1.4.1.738.1.5.100.1.1.19.3
OBJECT IDENTIFIER    

as9220 1.3.6.1.4.1.738.1.5.100.1.1.19.10
OBJECT IDENTIFIER    

tMetro-200S 1.3.6.1.4.1.738.1.5.100.1.1.19.11
OBJECT IDENTIFIER    

as9215 1.3.6.1.4.1.738.1.5.100.1.1.27.1
OBJECT IDENTIFIER    

bI-Ethernet 1.3.6.1.4.1.738.1.5.100.1.1.18.1
OBJECT IDENTIFIER    

fI-Ethernet 1.3.6.1.4.1.738.1.5.100.1.1.18.2
OBJECT IDENTIFIER    

t5c 1.3.6.1.4.1.738.1.5.100.1.1.100
OBJECT IDENTIFIER    

t5cgt 1.3.6.1.4.1.738.1.5.100.1.1.222
OBJECT IDENTIFIER    

t5g 1.3.6.1.4.1.738.1.5.100.1.1.333
OBJECT IDENTIFIER    

v24s 1.3.6.1.4.1.738.1.5.100.1.1.444
OBJECT IDENTIFIER    

edgeGate281 1.3.6.1.4.1.738.1.5.100.1.1.1000
OBJECT IDENTIFIER    

edgeGate281SYS 1.3.6.1.4.1.738.1.5.100.1.1.1001
OBJECT IDENTIFIER    

edgeGate231 1.3.6.1.4.1.738.1.5.100.1.1.1010
OBJECT IDENTIFIER    

edgeGate282 1.3.6.1.4.1.738.1.5.100.1.1.1020
OBJECT IDENTIFIER    

edgeGate282S 1.3.6.1.4.1.738.1.5.100.1.1.1021
OBJECT IDENTIFIER    

edgeGate482S 1.3.6.1.4.1.738.1.5.100.1.1.1022
OBJECT IDENTIFIER    

edgeGate483S 1.3.6.1.4.1.738.1.5.100.1.1.1023
OBJECT IDENTIFIER    

edgeGate483D 1.3.6.1.4.1.738.1.5.100.1.1.1024
OBJECT IDENTIFIER    

edgeGate201 1.3.6.1.4.1.738.1.5.100.1.1.1031
OBJECT IDENTIFIER    

edgeGate232 1.3.6.1.4.1.738.1.5.100.1.1.1041
OBJECT IDENTIFIER    

ac500 1.3.6.1.4.1.738.1.5.100.1.1.1050
OBJECT IDENTIFIER    

ac505 1.3.6.1.4.1.738.1.5.100.1.1.1050.1
OBJECT IDENTIFIER    

ac512 1.3.6.1.4.1.738.1.5.100.1.1.1050.2
OBJECT IDENTIFIER    

ac524 1.3.6.1.4.1.738.1.5.100.1.1.1050.3
OBJECT IDENTIFIER    

sysIntfTable 1.3.6.1.4.1.738.1.5.100.1.2.1
This table contains the interfaces module type.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysIntfEntry

sysIntfEntry 1.3.6.1.4.1.738.1.5.100.1.2.1.1
sysIntfEntry
Status: current Access: not-accessible
OBJECT-TYPE    
  SysIntfEntry  

sysStackNo 1.3.6.1.4.1.738.1.5.100.1.2.1.1.1
This object identifies the switch
Status: current Access: read-only
OBJECT-TYPE    
  UnitIndex  

sysSlotNo 1.3.6.1.4.1.738.1.5.100.1.2.1.1.2
This indicates a single instance of a slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..256  

sysIntfUnitExist 1.3.6.1.4.1.738.1.5.100.1.2.1.1.3
This indicates interface module type
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER uninstalled(1), installed(2)  

sysIntfModule 1.3.6.1.4.1.738.1.5.100.1.2.1.1.4
This indicates interface module type
Status: current Access: read-only
OBJECT-TYPE    
  ModuleHwType  

sysSerialNumber 1.3.6.1.4.1.738.1.5.100.1.3.1
This is the device's serial number, which is entered during the manufacturing process.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysSwitchModel 1.3.6.1.4.1.738.1.5.100.1.3.2
Specifies the equipment model
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysAssemblyNumber 1.3.6.1.4.1.738.1.5.100.1.3.3
Specifies the equipment assembly number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysPartNumber 1.3.6.1.4.1.738.1.5.100.1.3.4
Specifies the equipment part number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysCLEI 1.3.6.1.4.1.738.1.5.100.1.3.5
Specifies the common language equipment identification
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysHwRevision 1.3.6.1.4.1.738.1.5.100.1.3.6
Specifies the HW revision
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysManufacturingDate 1.3.6.1.4.1.738.1.5.100.1.3.7
Specifies the manufacturing date
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysSwitchSeries 1.3.6.1.4.1.738.1.5.100.1.4.1
This object displays the switch series.
Status: current Access: read-only
OBJECT-TYPE    
  Series  

configL2 1.3.6.1.4.1.738.1.5.100.2.2
OBJECT IDENTIFIER    

configL2SpanOnOff 1.3.6.1.4.1.738.1.5.100.2.2.1
Enables/disables Spanning Tree. When Spanning Tree is disabled, the switch's ports are placed in forwarding mode, regardless of the current Spanning Tree state. When re-enabled, the normal state transitions take place.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enableSTP(1), disable(2), enableRSTP(3), enablePVST(4), enableMST(5)  

configL2IfaceTable 1.3.6.1.4.1.738.1.5.100.2.2.2
A list of Interfaces and their properties
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConfigL2IfaceEntry

configL2IfaceEntry 1.3.6.1.4.1.738.1.5.100.2.2.2.1
An index of interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  ConfigL2IfaceEntry  

configL2IfaceUnit 1.3.6.1.4.1.738.1.5.100.2.2.2.1.1
An index that uniquely identifies a unit in the Interface Table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..1000  

configL2IfaceSlot 1.3.6.1.4.1.738.1.5.100.2.2.2.1.2
An index that uniquely identifies a slot within the unit in the Interface Table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..1000  

configL2IfacePort 1.3.6.1.4.1.738.1.5.100.2.2.2.1.3
An index that uniquely identifies a port within the slot in the Interface Table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..1000  

configL2IfaceName 1.3.6.1.4.1.738.1.5.100.2.2.2.1.4
The textual name of this interface, e.g., 'John'.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

configL2IfaceEnable 1.3.6.1.4.1.738.1.5.100.2.2.2.1.5
Enables (1)or disables (2) control for the interface. For this product, this is the ONLY way to enable or disable the interface. 'ifAdminStatus' in RFC1213 and 'dot1dStpPortEnable' in RFC1493 are both implemented as 'read-only'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

configL2IfaceSTPEnable 1.3.6.1.4.1.738.1.5.100.2.2.2.1.6
Enables (1) and disables (2) Spanning Tree operation for this interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

configL2IfaceDuplexSpeedSet 1.3.6.1.4.1.738.1.5.100.2.2.2.1.7
The desired speed and duplex mode for the interface. If the selected control is not available for the interface, a value of illegal (99) is returned. If the port type does NOT support the default of autonegotiate (1), then the application will initialize the port to a valid value (e.g., 1000full (6)). Note that not all controls are available for all interfaces. For example, only full-1000 (6) is available for Gigabit Ethernet interfaces. As this object was marked as obsolete the following two configurable parameters of an interface should be used: configL2IfaceDuplexModeSet, configL2IfaceSpeedSet
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER autonegotiate(1), half-10(2), full-10(3), half-100(4), full-100(5), half-1000(6), full-1000(7), pos-155(8), pos-622(9), full-10000(10), half-auto(11), full-auto(12), auto-10(13), auto-100(14), auto-1000(16), illegal(99)  

configL2IfaceFlow 1.3.6.1.4.1.738.1.5.100.2.2.2.1.8
The desired flow mode for the interface. If the selected control is not available on the interface, a value of illegal (99) is returned. If the port type does NOT support the default value of autonegotiate (1), then the application will initialize the port to a valid value (e.g., 1000full (6)).Note that not all controls are available for all interfaces. For example, only full-1000 (6) is available for Gigabit Ethernet interfaces.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER autonegotiate(1), flowon(2), flowoff(3)  

configL2IfaceBackpressure 1.3.6.1.4.1.738.1.5.100.2.2.2.1.9
The desired back-pressure mode for the interface. If the selected control is not available on the interface, a value of illegal (99) is returned.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER backpressureon(1), backpressureoff(2), illegal(99)  

configL2IfaceResetCounters 1.3.6.1.4.1.738.1.5.100.2.2.2.1.10
This object enables resetting the statistics counters selected for this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), reset(2)  

configL2IfaceDefaultVID 1.3.6.1.4.1.738.1.5.100.2.2.2.1.11
This object sets the default VLAN ID according to 802.1Q.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4095  

configL2IfaceSnifferIfIndex 1.3.6.1.4.1.738.1.5.100.2.2.2.1.12
This object connects this port to a sniffer port indexed by the specified ifIndex. Setting this value to 0 disconnects this port from the sniffer.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

configL2TopologyChangeDetection 1.3.6.1.4.1.738.1.5.100.2.2.2.1.13
This object controls the STP topology change detection for this interface.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

configL2IfaceDuplexModeSet 1.3.6.1.4.1.738.1.5.100.2.2.2.1.14
The duplex mode for the interface. If the port type does NOT support the default of autonegotiate (1), then the application will initialize the port to a valid value (e.g., full (2)).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), full(2), half(3)  

configL2IfaceSpeedSet 1.3.6.1.4.1.738.1.5.100.2.2.2.1.15
The desired speed and duplex mode for the interface. If the selected control is not available for the interface, a value of illegal (99) is returned. If the port type does NOT support the default of autonegotiate (1), then the application will initialize the port to a valid value (e.g., 1000 (3)). Note that not all controls are available for all interfaces. For example, only 1000 (4) is available for Gigabit Ethernet interfaces.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), speed-10(2), speed-100(3), speed-1000(4), speed-10000(5), pos-155(6), pos-622(7), illegal(99)  

configL2IfaceBroadcastRateLimit 1.3.6.1.4.1.738.1.5.100.2.2.2.1.16
Rate limit broadcast traffic. Must be a number between 64Kbps and 1Gbps, specified in Kbps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..2147483647  

configL2IfaceMulticastRateLimit 1.3.6.1.4.1.738.1.5.100.2.2.2.1.17
Rate limit multicast traffic. Must be a number between 64Kbps and 1Gbps, specified in Kbps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..2147483647  

configL2IfaceUnknownRateLimit 1.3.6.1.4.1.738.1.5.100.2.2.2.1.18
Rate limit unknown traffic. Must be a number between 64Kbps and 1Gbps, specified in Kbps. For detail information see documentation.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..2147483647  

configL2IfaceBroadcastBurstSize 1.3.6.1.4.1.738.1.5.100.2.2.2.1.19
Burst size broadcast traffic. Must be a number between 12Kbps and 1Mbps, specified in Kbps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..2147483647  

configL2IfaceMulticastBurstSize 1.3.6.1.4.1.738.1.5.100.2.2.2.1.20
Burst size multicast traffic. Must be a number between 12Kbps and 1Mbps, specified in Kbps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..2147483647  

configL2IfaceUnknownBurstSize 1.3.6.1.4.1.738.1.5.100.2.2.2.1.21
Burst size unknown traffic. Must be a number between 12Kbps and 1Mbps, specified in Kbps. For detail information see documentation.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..2147483647  

configL2IfaceMtu 1.3.6.1.4.1.738.1.5.100.2.2.2.1.22
The Maximum Transmission Unit (in octets) of the interface.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 512..9216  

configL2IfaceAdminCrossOver 1.3.6.1.4.1.738.1.5.100.2.2.2.1.23
The administrative MDI/MDI-X cable connection status of ports, as specified in IEEE 803.2. The mdi-x mode (crossover) is configured (3), the interface works in MDI-X mode. The mdi mode (2) defines port to work in standard MDI mode. The auto (1) defines automatic crossover detection, and any type of MDI/MDI-X cabling can be used on the port. Note: This attribute can be configured only on interfaces that support that option.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), mdi(2), mdi-x(3), unsupported(255)  

configL2IfaceRemoteFaultDetect 1.3.6.1.4.1.738.1.5.100.2.2.2.1.24
Controls the remote fault detection on interfaces, connected to 100Base Fiber pair. Once enabled (1), the switch will indicate link-down event on the interface, once remote peer detects link down. Note: Relevant only on 100Base Fiber interfaces.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enableRemoteFaultDetect(1), disableRemoteFaultDetect(2)  

reportsL2 1.3.6.1.4.1.738.1.5.100.3.1
OBJECT IDENTIFIER    

reportsL2IfaceTable 1.3.6.1.4.1.738.1.5.100.3.1.1
A list of Interfaces and their properties
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ReportsL2IfaceEntry

reportsL2IfaceEntry 1.3.6.1.4.1.738.1.5.100.3.1.1.1
An index of interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  ReportsL2IfaceEntry  

reportsL2IfaceUnit 1.3.6.1.4.1.738.1.5.100.3.1.1.1.1
An index that uniquely identifies a unit in the Interface Table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..1000  

reportsL2IfaceSlot 1.3.6.1.4.1.738.1.5.100.3.1.1.1.2
An index that uniquely identifies a slot within the unit in the Interface Table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..1000  

reportsL2IfacePort 1.3.6.1.4.1.738.1.5.100.3.1.1.1.3
An index that uniquely identifies a port within the slot in the Interface Table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..1000  

reportsL2IfaceBridgeIndex 1.3.6.1.4.1.738.1.5.100.3.1.1.1.4
This is the bridge index of this port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..1000  

reportsL2IfaceType 1.3.6.1.4.1.738.1.5.100.3.1.1.1.5
The type of interface, repeated here from the definitions in RFC1213 as a matter of convenience.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), regular1822(2), hdh1822(3), ddn-x25(4), rfc877-x25(5), ethernet-csmacd(6), iso88023-csmacd(7), iso88024-tokenBus(8), iso88025-tokenRing(9), iso88026-man(10), starLan(11), proteon-10Mbit(12), proteon-80Mbit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), ds1(18), e1(19), basicISDN(20), primaryISDN(21), propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), ethernet-3Mbit(26), nsip(27), slip(28), ultra(29), ds3(30), sip(31), frame-relay(32)  


reportsL2IfaceDuplexSpeedGet 1.3.6.1.4.1.738.1.5.100.3.1.1.1.7
The actual speed and duplex for the interface. If the interface is not configured to one of the acceptable values, a value of illegal (99) is returned.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), half-10(2), full-10(3), half-100(4), full-100(5), half-1000(6), full-1000(7), pos-155(8), pos-622(9), full-10000(10), illegal(99)  

reportsL2IfaceTXOctetsNoErr 1.3.6.1.4.1.738.1.5.100.3.1.1.1.8
The number of octets transmitted from the interface. This number does not include octets with errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceTXPacketsNoErr 1.3.6.1.4.1.738.1.5.100.3.1.1.1.9
The number of packets transmitted from the interface. This number does not include packets with errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceRXOctetsNoErr 1.3.6.1.4.1.738.1.5.100.3.1.1.1.10
The number of octets received on the interface. This number does not include octets with errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceRXPacketsNoErr 1.3.6.1.4.1.738.1.5.100.3.1.1.1.11
The number of packets received on the interface. This number does not include packets with errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfInOctets 1.3.6.1.4.1.738.1.5.100.3.1.1.1.12
The total number of octets received on the interface, including framing characters.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfInUcastPkts 1.3.6.1.4.1.738.1.5.100.3.1.1.1.13
The number of subnetwork-unicast packets delivered to a higher-layer protocol.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfInNUcastPkts 1.3.6.1.4.1.738.1.5.100.3.1.1.1.14
The number of non-unicast (i.e., subnetwork- broadcast or subnetwork-multicast) packets delivered to a higher-layer protocol.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfInDiscards 1.3.6.1.4.1.738.1.5.100.3.1.1.1.15
The number of inbound packets that were chosen to be discarded even if no errors that prevent their deliverability to a higher-layer protocol had been detected. One possible reason for discarding such a packet could be to free buffer space.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfInErrors 1.3.6.1.4.1.738.1.5.100.3.1.1.1.16
The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfInUnknownProtos 1.3.6.1.4.1.738.1.5.100.3.1.1.1.17
The number of packets received via the interface that were discarded because of an unknown or unsupported protocol.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfOutOctets 1.3.6.1.4.1.738.1.5.100.3.1.1.1.18
The total number of octets transmitted out of the interface, including framing characters.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfOutUcastPkts 1.3.6.1.4.1.738.1.5.100.3.1.1.1.19
The total number of packets that higher-level protocols requested to be transmitted to a subnetwork-unicast address, including those that were discarded or not sent.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfOutNUcastPkts 1.3.6.1.4.1.738.1.5.100.3.1.1.1.20
The total number of packets that higher-level protocols requested to be transmitted to a non- unicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address, including those that were discarded or not sent.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfOutDiscards 1.3.6.1.4.1.738.1.5.100.3.1.1.1.21
The number of outbound packets that were chosen to be discarded even if no errors that prevented their transmission had been detected. One possible reason for discarding such a packet could be to free up buffer space.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceIfOutErrors 1.3.6.1.4.1.738.1.5.100.3.1.1.1.22
The number of outbound packets that could not be transmitted because of errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsDropEvents 1.3.6.1.4.1.738.1.5.100.3.1.1.1.23
The total number of events in which packets were dropped by the probe due to lack of resources. Note that this number is not necessarily the number of packets dropped; it is just the number of times this condition has been detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsOctets 1.3.6.1.4.1.738.1.5.100.3.1.1.1.24
The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets). This object can be used as a reasonable estimate of Ethernet utilization. If greater precision is desired, the etherStatsPkts and etherStatsOctets objects should be sampled before and after a common interval. The differences in the sampled values are Pkts and Octets, respectively, and the number of seconds in the interval is Interval. These values are used to calculate the Utilization as follows: Pkts * (9.6 + 6.4) + (Octets * .8) Utilization = ------------------------------------- Interval * 10,000 The result of this equation is the Ethernet segment utilization which is the percent utilization of the ethernet segment on a 0 to 100 percent scale.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsPkts 1.3.6.1.4.1.738.1.5.100.3.1.1.1.25
The total number of packets (including bad packets, broadcast packets, and multicast packets) received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsBroadcastPkts 1.3.6.1.4.1.738.1.5.100.3.1.1.1.26
The total number of good packets received that were directed to the broadcast address. Note that this does not include multicast packets.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsMulticastPkts 1.3.6.1.4.1.738.1.5.100.3.1.1.1.27
The total number of good packets received that were directed to a multicast address. Note that this number does not include packets directed to the broadcast address.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsCRCAlignErrors 1.3.6.1.4.1.738.1.5.100.3.1.1.1.28
The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsUndersizePkts 1.3.6.1.4.1.738.1.5.100.3.1.1.1.29
The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsOversizePkts 1.3.6.1.4.1.738.1.5.100.3.1.1.1.30
The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsFragments 1.3.6.1.4.1.738.1.5.100.3.1.1.1.31
The total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Note that it is entirely normal for etherStatsFragments to increment. This is because it counts both runts (which are normal occurrences due to collisions) and noise hits.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsJabbers 1.3.6.1.4.1.738.1.5.100.3.1.1.1.32
The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Note that this definition of jabber is different from the definition in IEEE-802.3 section 8.2.1.5 (10BASE5) and section 10.3.1.4 (10BASE2). These documents define jabber as the condition in which any packet exceeds 20 ms. The allowed range to detect jabber is between 20 ms and 150 ms.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsCollisions 1.3.6.1.4.1.738.1.5.100.3.1.1.1.33
The best estimate of the total number of collisions on this Ethernet segment. The value returned will depend on the RMON probe's location. Sections 8.2.1.3 (10BASE-5) and 10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a station must detect a collision in the receive mode if three or more stations are transmitting simultaneously. A repeater port must detect a collision when two or more stations are transmitting simultaneously. Thus a probe placed on a repeater port could record more collisions than a probe connected to a station on the same segment would. Probe location plays a much smaller role when considering 10BASE-T. Section 14.2.1.4 (10BASE-T) of IEEE standard 802.3 defines a collision as the simultaneous presence of signals on the DO and RD circuits (transmitting and receiving at the same time). A 10BASE-T station can only detect collisions when it is transmitting. Thus probes placed on a station and a repeater, should report the same number of collisions. Note also that an RMON probe inside a repeater should ideally report collisions between the repeater and one or more other hosts (transmit collisions as defined by IEEE 802.3k) plus receiver collisions observed on any coaxial segments to which the repeater is connected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsPkts64Octets 1.3.6.1.4.1.738.1.5.100.3.1.1.1.34
The total number of packets (including bad packets) received that were 64 octets in length (excluding framing bits but including FCS octets).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsPkts65to127Octets 1.3.6.1.4.1.738.1.5.100.3.1.1.1.35
The total number of packets (including bad packets) received that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsPkts128to255Octets 1.3.6.1.4.1.738.1.5.100.3.1.1.1.36
The total number of packets (including bad packets) received that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsPkts256to511Octets 1.3.6.1.4.1.738.1.5.100.3.1.1.1.37
The total number of packets (including bad packets) received that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsPkts512to1023Octets 1.3.6.1.4.1.738.1.5.100.3.1.1.1.38
The total number of packets (including bad packets) received that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceStatsPkts1024to1518Octets 1.3.6.1.4.1.738.1.5.100.3.1.1.1.39
The total number of packets (including bad packets) received that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

reportsL2IfaceFlow 1.3.6.1.4.1.738.1.5.100.3.1.1.1.40
The flow control for the interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), flowon(2), flowoff(3)  

reportsL2IfaceHWType 1.3.6.1.4.1.738.1.5.100.3.1.1.1.41
The HW type of the interface.
Status: current Access: read-only
OBJECT-TYPE    
  ModuleHwType  

reportsL2IfaceActiveJackIndex 1.3.6.1.4.1.738.1.5.100.3.1.1.1.42
The current active jack index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

reportsHardware 1.3.6.1.4.1.738.1.5.100.3.2
OBJECT IDENTIFIER    

reportsHardwarePSStatus 1.3.6.1.4.1.738.1.5.100.3.2.1
Each OCTET holds the status of 1 power supply or if supported, a status of its corresponding power supply fan. Every octet can show one of the following states: 0 - power supply not installed; 1 - power supply is installed but does not function correctly; 2 - power supply is installed and working OK; There are devices, which can also show status of the Fan, attached to the power supply. All devices which support the Power Supply fan, will display their status in series of octet pairs. The fan status octet will be displayed right after the supply status octet.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..16)  

reportsHardwareFanStatus 1.3.6.1.4.1.738.1.5.100.3.2.2
Each OCTET holds the status of 1 fan 0 - Fan stopped 1 - Fan failed 2 - Fan OK
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..16)  

reportsHardwareTemperature 1.3.6.1.4.1.738.1.5.100.3.2.3
The internal temperature of the unit in degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

reportsHardwarePSVoltage 1.3.6.1.4.1.738.1.5.100.3.2.4
Each OCTET holds the voltage of a corresponding power supply. Every octet can show one of the following states: 0 - power supply not installed or voltage information is not supported; 1-C - power supply in V, hexadecimal;
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..16)  

reportsHardwareTemperatureScale 1.3.6.1.4.1.738.1.5.100.3.2.5
Displays the scale used - Celsius (Centigrade) or Fahrenheit when measuring CPU temperature. The value of this object determines the type of scale used for the values of reportsHardwareTemperature and reportsHardwareTemperatureHighLimit objects.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

reportsHardwareTemperatureHighLimit 1.3.6.1.4.1.738.1.5.100.3.2.6
Displays the highest allowed Celsius (Centigrade) or Fahrenheit temperature at the unit CPU area. When this limit is reached an SNMP notification is sent.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 20..70  

reportsHardwareDoorStatus 1.3.6.1.4.1.738.1.5.100.3.2.7
Status of door 0 - Door not installed 1 - Door open 2 - Door closed
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2  

reportsIfJack 1.3.6.1.4.1.738.1.5.100.3.3
OBJECT IDENTIFIER    

reportsIfJackTable 1.3.6.1.4.1.738.1.5.100.3.3.2
Information about the external jacks attached to MAUs attached to an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ReportsIfJackEntry

reportsIfJackEntry 1.3.6.1.4.1.738.1.5.100.3.3.2.1
An entry in the table, containing information about a particular jack.
Status: current Access: not-accessible
OBJECT-TYPE    
  ReportsIfJackEntry  

reportsIfJackIndex 1.3.6.1.4.1.738.1.5.100.3.3.2.1.1
This variable uniquely identifies the jack described by this entry from among other jacks attached to the same MAU.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

reportsIfJackType 1.3.6.1.4.1.738.1.5.100.3.3.2.1.2
The jack connector type, as it appears on the outer side of the system.
Status: current Access: read-only
OBJECT-TYPE    
  ModuleHwType  

cpuTemperatureExceeded 1.3.6.1.4.1.738.1.5.100.0.1
The cpuTemperatuteExceeded trap indicates that the sending agent senses that the internal temperature has passed the program threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupplyStatusChange 1.3.6.1.4.1.738.1.5.100.0.2
The powerSupplyStatusChange trap indicates that the sending agent senses a change in the status of one of the power supplies.
Status: current Access: read-only
NOTIFICATION-TYPE    

fanStatusChange 1.3.6.1.4.1.738.1.5.100.0.3
The fanStatusChange trap indicates that the sending agent senses a change in the status of one of the fans.
Status: current Access: read-only
NOTIFICATION-TYPE    

portSecurityViolation 1.3.6.1.4.1.738.1.5.100.0.4
The port security violation notification indicates that a port security violation has been detected, e.g more MAC adresses have been learned on that port than the number allowed.
Status: current Access: read-only
NOTIFICATION-TYPE    

portRedundantLinkChange 1.3.6.1.4.1.738.1.5.100.0.5
The port redundant link change notification indicates that the physical state of a redundant (i.e. blocked or discarding) link has changed from link-up to link down or vice versa.
Status: current Access: read-only
NOTIFICATION-TYPE    

sysIntfModuleChange 1.3.6.1.4.1.738.1.5.100.0.6
The System Interface Module change notification indicates that the physical status of a module in the unit has changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

prvtLogNotifyFull 1.3.6.1.4.1.738.1.5.100.0.7
Log buffer is almost full.
Status: current Access: read-only
NOTIFICATION-TYPE    

doorStatusChange 1.3.6.1.4.1.738.1.5.100.0.8
The doorStatusChange trap indicates that the sending agent senses a change in the status of the door.
Status: current Access: read-only
NOTIFICATION-TYPE    

prvtSwitchMIBGroups 1.3.6.1.4.1.738.1.5.100.6.2
OBJECT IDENTIFIER    

prvtSwitchNotificationGroup 1.3.6.1.4.1.738.1.5.100.6.2.3
Private Notification Group.
Status: current Access: read-only
NOTIFICATION-GROUP