PRVT-CES-MIB

File: PRVT-CES-MIB.mib (35335 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC DS1-MIB
SNMPv2-CONF PRVT-SWITCH-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE IpAddress
Gauge32 Integer32 Unsigned32
NOTIFICATION-TYPE TimeStamp dsx1ConfigEntry
TEXTUAL-CONVENTION MODULE-COMPLIANCE NOTIFICATION-GROUP
OBJECT-GROUP switch

Defined Types

ConfigAction  
This value is used to specify what is to be done with unapplied CES module configuration.
TEXTUAL-CONVENTION    
  INTEGER noop(1), applyConfiguration(2), rejectConfiguration(3), restart(4)  

E1Impedance  
This value is used to configure E1 line type termination impedance.
TEXTUAL-CONVENTION    
  INTEGER notApplicable(0), e1-75ohm(1), e1-75hrl(2), e1-120ohm(3), e1-120hrl(4)  

T1LongCableLength  
This value is used to configure T1 long cable length.
TEXTUAL-CONVENTION    
  INTEGER notApplicable(1), neg75dB(2), neg15dB(3), neg225dB(4), zerodB(5)  

T1GainLimit  
This value is used to configure T1 type Tx or Rx gain limit.
TEXTUAL-CONVENTION    
  INTEGER notApplicable(0), none(1), gain30(2), gain36(3)  

CESLineType  
This value is used to configure the line mode common for all TDM ports of the module.
TEXTUAL-CONVENTION    
  INTEGER e1(1), t1(2), e1-sdh(3), t1-sdh(4), t1-sonet(5)  

ServiceClock  
This values are used to configure transmit clock as one of this modes.
TEXTUAL-CONVENTION    
  INTEGER notAplicable(0), loopTiming(1), localTiming(2), adaptive(3), differntial(4)  

PrvtCESDsx1ExtEntry  
SEQUENCE    
  prvtCESE1Impedance E1Impedance
  prvtCEST1GainLimit T1GainLimit
  prvtCESPortShutdown INTEGER
  prvtCESPortLineType INTEGER
  prvtCEST1LongCableLength T1LongCableLength
  prvtCESPortOperStatus INTEGER
  prvtCESClearPortStatistics INTEGER
  prvtCESServiceClock ServiceClock

PrvtCESUnappEntry  
SEQUENCE    
  prvtCESUnappLineType INTEGER
  prvtCESUnappLineCoding INTEGER
  prvtCESUnappLoopbackConfig INTEGER
  prvtCESUnappSignalMode INTEGER
  prvtCESUnappTransmitClockSource INTEGER
  prvtCESUnappTransmitClockBackup INTEGER
  prvtCESUnappLineLength Integer32
  prvtCESUnappLineMode INTEGER
  prvtCESUnappLineBuildOut INTEGER
  prvtCESUnappE1Impedance E1Impedance
  prvtCESUnappT1GainLimit T1GainLimit
  prvtCESUnappIPAddress IpAddress
  prvtCESUnappIPAddressMask IpAddress
  prvtCESUnappGateway IpAddress

PrvtCESModuleConfEntry  
SEQUENCE    
  prvtCESModuleIndex Integer32
  prvtCESModuleLineType CESLineType
  prvtCESModuleTxClock INTEGER
  prvtCESModuleTxBackupClock INTEGER
  prvtCESModuleConfig ConfigAction
  prvtCESModuleIPAddress IpAddress
  prvtCESModuleIPAddressMask IpAddress
  prvtCESModuleGateway IpAddress
  prvtCESModuleUpTime TimeStamp
  prvtCESModuleMACAddress OCTET STRING
  prvtCESModuleHardwareRevision OCTET STRING
  prvtCESModuleFirmwareVersion OCTET STRING
  prvtCESModuleClearCircuitStatistics INTEGER
  prvtCESModuleLbit INTEGER
  prvtCESModulePolicyLops INTEGER
  prvtCESModulePolicyLbit INTEGER
  prvtCESModulePolicyRbit INTEGER
  prvtCESModulePolicyRd INTEGER
  prvtCESModulePolicyIdlePattern Unsigned32
  prvtCESModulePolicyIdleSignalling Unsigned32
  prvtCESModulePolicyLopsEnter Integer32
  prvtCESModulePolicyLopsExit Integer32
  prvtCESModulePolicyuUnstrLbit INTEGER
  prvtCESModulePolicyuStrReplace INTEGER
  prvtCESModulePolicyuUnstrReplace INTEGER
  prvtCESModulePolicyuUnstrLops INTEGER
  prvtCESModuleServiceClock ServiceClock
  prvtCESModulePolicyuUnstrReplacePattern Integer32

PrvtCESDsx1AlarmEntry  
SEQUENCE    
  prvtCESDsx1AlarmPort Integer32
  prvtCESDsx1AlarmIndex Gauge32
  prvtCESDsx1AlarmVariable OBJECT IDENTIFIER
  prvtCESDsx1AlarmThreshold Integer32
  prvtCESDsx1AlarmValue Integer32

PrvtCESCICEntry  
SEQUENCE    
  prvtCESCICModuleId Integer32
  prvtCESCICNumber Gauge32
  prvtCESCICClockNumber Integer32
  prvtCESCICMode INTEGER
  prvtCESCICTdmPort Integer32
  prvtCESCICCircuit Integer32
  prvtCESCICStatus INTEGER
  prvtCESCICState INTEGER

PrvtCESCICMappEntry  
SEQUENCE    
  prvtCESCICMappModuleId Integer32
  prvtCESCICMappClockNumber Gauge32
  prvtCESCICMappCICNumber Gauge32
  prvtCESCICMappState INTEGER

PrvtCESApsEntry  
SEQUENCE    
  prvtCESApsModuleId Integer32
  prvtCESApsEnable INTEGER
  prvtCESApsActiveLine Integer32
  prvtSdBerThreshold Integer32
  prvtSfBerThreshold Integer32

PrvtCESUpdateFirmwareEntry  
SEQUENCE    
  prvtCESModuleId Integer32
  prvtCESFirmwareImageName OCTET STRING
  prvtCESUpdateAction INTEGER
  prvtCESUpdateStatus INTEGER
  prvtCESTFTPServer IpAddress

Defined Values

prvtCESMib 1.3.6.1.4.1.738.1.5.111
This module includes configuration parameters for DS1 modules not included in DS1-MIB.
MODULE-IDENTITY    

prvtCESNotifications 1.3.6.1.4.1.738.1.5.111.0
OBJECT IDENTIFIER    

prvtCESObjects 1.3.6.1.4.1.738.1.5.111.1
OBJECT IDENTIFIER    

prvtCESConformance 1.3.6.1.4.1.738.1.5.111.2
OBJECT IDENTIFIER    

prvtCESDsx1ExtTable 1.3.6.1.4.1.738.1.5.111.1.1
This table contains object for configuring DS1 interfaces, not supported in dsx1ConfigTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrvtCESDsx1ExtEntry

prvtCESDsx1ExtEntry 1.3.6.1.4.1.738.1.5.111.1.1.1
prvtCESDsx1ExtEntry
Status: current Access: not-accessible
OBJECT-TYPE    
  PrvtCESDsx1ExtEntry  

prvtCESE1Impedance 1.3.6.1.4.1.738.1.5.111.1.1.1.1
This object configures temination impedance for TDM ports if the line type is E1.
Status: current Access: read-write
OBJECT-TYPE    
  E1Impedance  

prvtCEST1GainLimit 1.3.6.1.4.1.738.1.5.111.1.1.1.2
This object configures Tx or Rx gain limit for TDM ports if the line type is T1.
Status: current Access: read-write
OBJECT-TYPE    
  T1GainLimit  

prvtCESPortShutdown 1.3.6.1.4.1.738.1.5.111.1.1.1.3
Shutdown TDM port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

prvtCESPortLineType 1.3.6.1.4.1.738.1.5.111.1.1.1.4
Additional line types. For reference see object dsx1LineType
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), dsx1ESF(2), dsx1D4(3), dsx1E1(4), dsx1E1CRC(5), dsx1E1MF(6), dsx1E1CRCMF(7), dsx1Unframed(8), dsx1E1Unframed(9), dsx1DS2M12(10), dsx1E2(11), dsx1E1Q50(12), dsx1E1Q50CRC(13), dsx1SFCAS(14), dsx1ESFCAS(15), notApplicable(16)  

prvtCEST1LongCableLength 1.3.6.1.4.1.738.1.5.111.1.1.1.5
Long cable length options for T1 mode.
Status: current Access: read-write
OBJECT-TYPE    
  T1LongCableLength  

prvtCESPortOperStatus 1.3.6.1.4.1.738.1.5.111.1.1.1.6
TDM link state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3), unknown(4), dormant(5), notPresent(6), lowerlayerDown(7)  

prvtCESClearPortStatistics 1.3.6.1.4.1.738.1.5.111.1.1.1.7
Clear port statistics.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), clear(1)  

prvtCESServiceClock 1.3.6.1.4.1.738.1.5.111.1.1.1.8
Service Clock available only for DS1 interface.
Status: current Access: read-write
OBJECT-TYPE    
  ServiceClock  

prvtCESUnappTable 1.3.6.1.4.1.738.1.5.111.1.3
This table displays CES module configuration which will take effect after prvtCESModuleConf is set to applyConfiguration(2).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrvtCESUnappEntry

prvtCESUnappEntry 1.3.6.1.4.1.738.1.5.111.1.3.1
prvtCESUnappEntry
Status: current Access: not-accessible
OBJECT-TYPE    
  PrvtCESUnappEntry  

prvtCESUnappLineType 1.3.6.1.4.1.738.1.5.111.1.3.1.1
The value of dsx1LineType before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), dsx1ESF(2), dsx1D4(3), dsx1E1(4), dsx1E1CRC(5), dsx1E1MF(6), dsx1E1CRCMF(7), dsx1Unframed(8), dsx1E1Unframed(9), dsx1DS2M12(10), dsx1E2(11), dsx1E1Q50(12), dsx1E1Q50CRC(13)  

prvtCESUnappLineCoding 1.3.6.1.4.1.738.1.5.111.1.3.1.2
The value of dsx1LineCoding before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER dsx1JBZS(1), dsx1B8ZS(2), dsx1HDB3(3), dsx1ZBTSI(4), dsx1AMI(5), other(6), dsx1B6ZS(7)  

prvtCESUnappLoopbackConfig 1.3.6.1.4.1.738.1.5.111.1.3.1.3
The value of dsx1LoopbackConfig before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER dsx1NoLoop(1), dsx1PayloadLoop(2), dsx1LineLoop(3), dsx1OtherLoop(4), dsx1InwardLoop(5), dsx1DualLoop(6)  

prvtCESUnappSignalMode 1.3.6.1.4.1.738.1.5.111.1.3.1.4
The value of dsx1SignalMode before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), robbedBit(2), bitOriented(3), messageOriented(4), other(5)  

prvtCESUnappTransmitClockSource 1.3.6.1.4.1.738.1.5.111.1.3.1.5
The value of dsx1TransmitClockSource before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), throughTiming(3), adaptive(4), external-port(5)  

prvtCESUnappTransmitClockBackup 1.3.6.1.4.1.738.1.5.111.1.3.1.6
The value of dsx1TransmitClockBackup before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

prvtCESUnappLineLength 1.3.6.1.4.1.738.1.5.111.1.3.1.7
The value of dsx1LineLength before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..64000  

prvtCESUnappLineMode 1.3.6.1.4.1.738.1.5.111.1.3.1.8
The value of dsx1LineMode before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER csu(1), dsu(2)  

prvtCESUnappLineBuildOut 1.3.6.1.4.1.738.1.5.111.1.3.1.9
The value of dsx1LineBuildOut before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), neg75dB(2), neg15dB(3), neg225dB(4), zerodB(5)  

prvtCESUnappE1Impedance 1.3.6.1.4.1.738.1.5.111.1.3.1.10
The value of prvtCESE1Impedance before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  E1Impedance  

prvtCESUnappT1GainLimit 1.3.6.1.4.1.738.1.5.111.1.3.1.11
The value of prvtCEST1GainLimit before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  T1GainLimit  

prvtCESUnappIPAddress 1.3.6.1.4.1.738.1.5.111.1.3.1.12
The CES Module IP address before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

prvtCESUnappIPAddressMask 1.3.6.1.4.1.738.1.5.111.1.3.1.13
The CES Module IP address mask before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

prvtCESUnappGateway 1.3.6.1.4.1.738.1.5.111.1.3.1.14
The CES Module Gateway before configuration is applied.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

prvtCESModuleConfTable 1.3.6.1.4.1.738.1.5.111.1.2
This table contains object for configuring options that are applied to the entire module.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrvtCESModuleConfEntry

prvtCESModuleConfEntry 1.3.6.1.4.1.738.1.5.111.1.2.1
prvtCESModuleConfEntry
Status: current Access: not-accessible
OBJECT-TYPE    
  PrvtCESModuleConfEntry  

prvtCESModuleIndex 1.3.6.1.4.1.738.1.5.111.1.2.1.1
Index of each CES module installed.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..65535  

prvtCESModuleLineType 1.3.6.1.4.1.738.1.5.111.1.2.1.2
Line mode for the module.
Status: current Access: read-write
OBJECT-TYPE    
  CESLineType  

prvtCESModuleTxClock 1.3.6.1.4.1.738.1.5.111.1.2.1.3
Configures Transmit Source Clock for the module.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), throughTiming(3), adaptive(4), external-port(5), line(6), ptp(7)  

prvtCESModuleTxBackupClock 1.3.6.1.4.1.738.1.5.111.1.2.1.4
Configures Backup Clock for the module.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

prvtCESModuleConfig 1.3.6.1.4.1.738.1.5.111.1.2.1.5
When this object is set to applyConfiguration(2), the module is restarted and the changes in dsx1ConfigTable or prvtCESConfTable are applied. The object must be set to rejectConfiguration(3) to remove unapplied changes. If the object is set to restart(4), the module is restarted with applying the changes. This object always returns a value of noop(1) when get.
Status: current Access: read-write
OBJECT-TYPE    
  ConfigAction  

prvtCESModuleIPAddress 1.3.6.1.4.1.738.1.5.111.1.2.1.6
The CES Module IP address after configuration is applied.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prvtCESModuleIPAddressMask 1.3.6.1.4.1.738.1.5.111.1.2.1.7
The CES Module IP address mask after configuration is applied.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prvtCESModuleGateway 1.3.6.1.4.1.738.1.5.111.1.2.1.8
CES Module Gateway after configuration is applied.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prvtCESModuleUpTime 1.3.6.1.4.1.738.1.5.111.1.2.1.9
CES Up Time
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

prvtCESModuleMACAddress 1.3.6.1.4.1.738.1.5.111.1.2.1.10
CES MAC Address
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prvtCESModuleHardwareRevision 1.3.6.1.4.1.738.1.5.111.1.2.1.11
CES Hardware revision
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prvtCESModuleFirmwareVersion 1.3.6.1.4.1.738.1.5.111.1.2.1.12
CES Firmware revision
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prvtCESModuleClearCircuitStatistics 1.3.6.1.4.1.738.1.5.111.1.2.1.13
Clear circuits statistics.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), clear(1)  

prvtCESModuleLbit 1.3.6.1.4.1.738.1.5.111.1.2.1.14
Enable/disable L bit set upon AIS defect detection, in structure agnostic mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

prvtCESModulePolicyLops 1.3.6.1.4.1.738.1.5.111.1.2.1.15
Controls policy lops. Object does not require module to be restarted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), all-one(1), channel-idle(2), none(3)  

prvtCESModulePolicyLbit 1.3.6.1.4.1.738.1.5.111.1.2.1.16
Controls policy lbit. Object does not require module to be restarted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), all-one(1), channel-idle(2), none(3)  

prvtCESModulePolicyRbit 1.3.6.1.4.1.738.1.5.111.1.2.1.17
Controls policy rbit. Object does not require module to be restarted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), rai(1), channel-idle(2)  

prvtCESModulePolicyRd 1.3.6.1.4.1.738.1.5.111.1.2.1.18
Controls policy rd. Object does not require module to be restarted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), rai(1), channel-idle(2)  

prvtCESModulePolicyIdlePattern 1.3.6.1.4.1.738.1.5.111.1.2.1.19
Controls policy idle pattern. Object does not require module to be restarted.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

prvtCESModulePolicyIdleSignalling 1.3.6.1.4.1.738.1.5.111.1.2.1.20
Controls policy idle signalling. Object does not require module to be restarted.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..15  

prvtCESModulePolicyLopsEnter 1.3.6.1.4.1.738.1.5.111.1.2.1.21
Controls the number of consecutive missed packets required to enter LOPS state. Object does not require module to be restarted.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..1023  

prvtCESModulePolicyLopsExit 1.3.6.1.4.1.738.1.5.111.1.2.1.22
Controls the number of consecutive missed packets required to exit LOPS state. Object does not require module to be restarted.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..1023  

prvtCESModulePolicyuUnstrLbit 1.3.6.1.4.1.738.1.5.111.1.2.1.23
If a packet is received with L bit set, and the payload is present (not suppressed), one of the following is sent to the TDM line, according to a globally configurable unstructured L-flag policy: The AIS pattern all-one The received payload as-is none
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), all-one(1)  

prvtCESModulePolicyuStrReplace 1.3.6.1.4.1.738.1.5.111.1.2.1.24
If a missing packet is detected, one of the following is sent to the TDM line, according to a globally configurable structured missing packet replacement policy: The AIS pattern all-one on the relevant timeslots The configured IDLE pattern
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER all-one(1), idle(2)  

prvtCESModulePolicyuUnstrReplace 1.3.6.1.4.1.738.1.5.111.1.2.1.25
If a missing packet is detected, one of the following is sent to the TDM line, according to a globally configurable unstructured missing packet replacement policy: The AIS pattern all-one The configured IDLE pattern
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER all-one(1), idle(2)  

prvtCESModulePolicyuUnstrLops 1.3.6.1.4.1.738.1.5.111.1.2.1.26
If a CES circuit enters the LOPS state, one of the following is sent to the TDM line, according to a globally configurable unstructured missing packet replacement policy: The AIS pattern all-one The contents of the jitter buffer - none
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), all-one(1)  

prvtCESModuleServiceClock 1.3.6.1.4.1.738.1.5.111.1.2.1.27
Clock mode for CES module
Status: current Access: read-write
OBJECT-TYPE    
  ServiceClock  

prvtCESModulePolicyuUnstrReplacePattern 1.3.6.1.4.1.738.1.5.111.1.2.1.28
Unstructured packet replace policy pattern number
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

prvtCESDsx1AlarmTable 1.3.6.1.4.1.738.1.5.111.1.4
This table contains object for configuring and displaying TDM ports TCA thresholds.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrvtCESDsx1AlarmEntry

prvtCESDsx1AlarmEntry 1.3.6.1.4.1.738.1.5.111.1.4.1
prvtCESDsx1AlarmEntry
Status: current Access: not-accessible
OBJECT-TYPE    
  PrvtCESDsx1AlarmEntry  

prvtCESDsx1AlarmPort 1.3.6.1.4.1.738.1.5.111.1.4.1.1
The DS1 port for which this alarm is configured.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..65535  

prvtCESDsx1AlarmIndex 1.3.6.1.4.1.738.1.5.111.1.4.1.2
An integer uniquely identifying an alarm entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Gauge32  

prvtCESDsx1AlarmVariable 1.3.6.1.4.1.738.1.5.111.1.4.1.3
The OID of the variable whose value is being monitored. Depending on the time interval, the error condition and the ifIndex of the TDM interface, this points to an object from an entry in dsx1CurrentTable or dsx1TotalTable.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

prvtCESDsx1AlarmThreshold 1.3.6.1.4.1.738.1.5.111.1.4.1.4
The alarm condition threshold for this alarm entry. The alarm is triggered if the value of the object pointed by prvtCESDsx1AlarmVariable remains above this threshold for more than 3 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prvtCESDsx1AlarmValue 1.3.6.1.4.1.738.1.5.111.1.4.1.5
The value of the object pointed to by prvtCESDsx1AlarmVariable, present for notification purposes.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

prvtCESAlarmMonitor 1.3.6.1.4.1.738.1.5.111.1.5
CES alarm monitor
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

prvtCESCICTable 1.3.6.1.4.1.738.1.5.111.1.6
This table contains objects for configuring Clock Input Controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrvtCESCICEntry

prvtCESCICEntry 1.3.6.1.4.1.738.1.5.111.1.6.1
prvtCESCICEntry
Status: current Access: not-accessible
OBJECT-TYPE    
  PrvtCESCICEntry  

prvtCESCICModuleId 1.3.6.1.4.1.738.1.5.111.1.6.1.1
Slot of CES module installed.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

prvtCESCICNumber 1.3.6.1.4.1.738.1.5.111.1.6.1.2
An integer uniquely identifying a Clock Input Controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  Gauge32  

prvtCESCICClockNumber 1.3.6.1.4.1.738.1.5.111.1.6.1.3
This variable indicates the index of the clock the clock input controller belongs to
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prvtCESCICMode 1.3.6.1.4.1.738.1.5.111.1.6.1.4
The mode of the clock input controller. Not all clock input controllers support all modes. The clock input controller status is 'locked' only if the clock input controller is in 'normal' mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER freeRun(1), acquisition(2), normal(3), holdover(4), fastAcquisiton(5)  

prvtCESCICTdmPort 1.3.6.1.4.1.738.1.5.111.1.6.1.5
If the clock input controller recovers a clock from a port , this variable indicates the TDM Port. Otherwise, it must be set to zero.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..4  

prvtCESCICCircuit 1.3.6.1.4.1.738.1.5.111.1.6.1.6
If the clock input controller recovers a clock from a circuit, this variable indicates the circuit ID. Otherwise, it must be set to zero.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prvtCESCICStatus 1.3.6.1.4.1.738.1.5.111.1.6.1.7
The status of the input reference.Reference is ok when the status is 'locked'. Otherwise, the status is 'notLocked'. Alternatively, if an error was detected at the input, the status indicates this error.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER locked(1), notlocked(2), sourceInputLost(3), sourceInputDegraded(4), sourceTraceLost(5), sourceTraceDegraded(6), sourceFreqOffsetFailure(7), recoveredClockDegraded(8), localReferenceFailure(9), remoteReferenceFailure(10)  

prvtCESCICState 1.3.6.1.4.1.738.1.5.111.1.6.1.8
The state is set to 'active' if the input controller was selected by the clock to drive the clock output. At least one input out of the clock-input-controllers attached to a clock must be in an 'active' state at any given time
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), backup(2)  

prvtCESCICMappTable 1.3.6.1.4.1.738.1.5.111.1.7
This table contains clock configuration and status monitoring information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrvtCESCICMappEntry

prvtCESCICMappEntry 1.3.6.1.4.1.738.1.5.111.1.7.1
prvtCESCICMappEntry
Status: current Access: not-accessible
OBJECT-TYPE    
  PrvtCESCICMappEntry  

prvtCESCICMappModuleId 1.3.6.1.4.1.738.1.5.111.1.7.1.1
Slot of CES module installed.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prvtCESCICMappClockNumber 1.3.6.1.4.1.738.1.5.111.1.7.1.2
Index for the conceptual row identifying a clock within this mapping table
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prvtCESCICMappCICNumber 1.3.6.1.4.1.738.1.5.111.1.7.1.3
Index for the conceptual row identifying a clock input within this mapping table
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prvtCESCICMappState 1.3.6.1.4.1.738.1.5.111.1.7.1.4
The state is set to 'active' if the input controller was selected by the clock to drive the clock output. At least one input out of the clock-input-controllers attached to a clock must be in an 'active' state at any given time This value of this variable is equal to the prvtCESCICState variable in the CIC table
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), backup(2)  

prvtCESApsTable 1.3.6.1.4.1.738.1.5.111.1.8
This table contains objects needed APS configuration
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrvtCESApsEntry

prvtCESApsEntry 1.3.6.1.4.1.738.1.5.111.1.8.1
prvtCESApsEntry
Status: current Access: not-accessible
OBJECT-TYPE    
  PrvtCESApsEntry  

prvtCESApsModuleId 1.3.6.1.4.1.738.1.5.111.1.8.1.1
An integer uniquely identifying slot of the CES module installed
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

prvtCESApsEnable 1.3.6.1.4.1.738.1.5.111.1.8.1.2
Enable/Disable Automatic Protection Switching
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

prvtCESApsActiveLine 1.3.6.1.4.1.738.1.5.111.1.8.1.3
APS active line
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..2  

prvtSdBerThreshold 1.3.6.1.4.1.738.1.5.111.1.8.1.4
The Signal Degrade Bit Error Rate. The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER). For example, a value of 5 indicates a BER threshold of 10^-5.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 5..9  

prvtSfBerThreshold 1.3.6.1.4.1.738.1.5.111.1.8.1.5
The Signal Failure Bit Error Rate. The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER). For example, a value of 5 indicates a BER threshold of 10^-5.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..5  

prvtCESUpdateFirmwareTable 1.3.6.1.4.1.738.1.5.111.1.9
This table contains object needed in update firmware of CES module
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrvtCESUpdateFirmwareEntry

prvtCESUpdateFirmwareEntry 1.3.6.1.4.1.738.1.5.111.1.9.1
prvtCESUpdateFirmwareEntry
Status: current Access: not-accessible
OBJECT-TYPE    
  PrvtCESUpdateFirmwareEntry  

prvtCESModuleId 1.3.6.1.4.1.738.1.5.111.1.9.1.1
An integer uniquely identifying slot of the CES module installed
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..32000  

prvtCESFirmwareImageName 1.3.6.1.4.1.738.1.5.111.1.9.1.2
Name of the firmware image file
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prvtCESUpdateAction 1.3.6.1.4.1.738.1.5.111.1.9.1.3
Update CES firmware
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), update(2), updateThroughUART(3)  

prvtCESUpdateStatus 1.3.6.1.4.1.738.1.5.111.1.9.1.4
The status of the last update procedure, if any. This object will have a value of updateStatusUnknown(2) if no update process has been performed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER updateStatusUnknown(1), updateSuccess(2), updateInProgress(3), updateFailed(4)  

prvtCESTFTPServer 1.3.6.1.4.1.738.1.5.111.1.9.1.5
IP Address of Tftp Server
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prvtCESDsx1Alarm 1.3.6.1.4.1.738.1.5.111.0.1
This notification is sent when the value of a TDM port error condition statistic has exceeded the configured threshold.
Status: current Access: read-write
NOTIFICATION-TYPE    

prvtCESModuleAvailable 1.3.6.1.4.1.738.1.5.111.0.2
prvtCESModuleAvailable trap
Status: current Access: read-write
NOTIFICATION-TYPE    

prvtCESModuleUnAvailableDueExtract 1.3.6.1.4.1.738.1.5.111.0.3
prvtCESModuleUnAvailableDueExtract trap.
Status: current Access: read-write
NOTIFICATION-TYPE    

prvtCESModuleUnAvailableDueReload 1.3.6.1.4.1.738.1.5.111.0.4
prvtCESModuleUnAvailableDueReload trap
Status: current Access: read-write
NOTIFICATION-TYPE    

prvtCESDsx1Compliances 1.3.6.1.4.1.738.1.5.111.2.1
OBJECT IDENTIFIER    

prvtCESDsx1Groups 1.3.6.1.4.1.738.1.5.111.2.2
OBJECT IDENTIFIER    

prvtCESDsx1Compliance 1.3.6.1.4.1.738.1.5.111.2.1.1
The compliance statement for management of TDM ports.
Status: current Access: read-write
MODULE-COMPLIANCE    

prvtCESDsx1NotificationsGroup 1.3.6.1.4.1.738.1.5.111.2.2.1
The group of supported notifications.
Status: current Access: read-write
NOTIFICATION-GROUP    

prvtCESDsx1ROGroup 1.3.6.1.4.1.738.1.5.111.2.2.2
The group of objects with MAX-ACCESS read-write supported with read-only access for the first release.
Status: current Access: read-write
OBJECT-GROUP