PICA-PRIVATE-MIB
File:
PICA-PRIVATE-MIB.mib (10037 bytes)
Imported modules
Imported symbols
Defined Types
SfpstatusEntry |
|
SEQUENCE |
|
|
|
|
sfpIndex |
INTEGER |
|
|
sfpVendorName |
DisplayString |
|
|
sfpSerialNumber |
DisplayString |
|
|
sfpTemp |
Integer32 |
|
|
sfpVoltage |
Integer32 |
|
|
sfpBias |
Integer32 |
|
|
sfpTxPower |
Integer32 |
|
|
sfpRxPower |
Integer32 |
|
|
sfpType |
DisplayString |
|
RpsustatusEntry |
|
SEQUENCE |
|
|
|
|
rpsuIndex |
INTEGER |
|
|
rpsuStatus |
INTEGER |
|
Defined Values
picaPrivateMib |
1.3.6.1.4.1.35098 |
The MIB module to manage Pica8's Pronto product. |
MODULE-IDENTITY |
|
|
|
cpuUsage |
1.3.6.1.4.1.35098.1.1 |
The usage of CPU, the output format is integer. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..100 |
|
totalPhyMemory |
1.3.6.1.4.1.35098.1.2 |
The total physical memory size, the output format is string. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
usedPhyMemory |
1.3.6.1.4.1.35098.1.3 |
The used physical memory size, the output format is string. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
freePhyMemory |
1.3.6.1.4.1.35098.1.4 |
The free physical memory size, the output format is string. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
switchTemperature |
1.3.6.1.4.1.35098.1.5 |
The temperature of switch, the output format is integer. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..500 |
|
cpuTemperature |
1.3.6.1.4.1.35098.1.6 |
The teperature of CPU, the output format is integer. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..500 |
|
switchChipTemperature |
1.3.6.1.4.1.35098.1.7 |
The teperature of switch chip, the output format is integer. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..500 |
|
sfpstatusTable |
1.3.6.1.4.1.35098.1.8 |
A list of sfp moudule status entries. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SfpstatusEntry |
|
sfpstatusEntry |
1.3.6.1.4.1.35098.1.8.1 |
An entry containing all sfp module stauts |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SfpstatusEntry |
|
|
sfpIndex |
1.3.6.1.4.1.35098.1.8.1.1 |
The port number of interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..2147483647 |
|
sfpVendorName |
1.3.6.1.4.1.35098.1.8.1.2 |
The vendor name of sfp ransceiver transfer. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sfpSerialNumber |
1.3.6.1.4.1.35098.1.8.1.3 |
The serial number of sfp ransceiver transfer. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sfpTemp |
1.3.6.1.4.1.35098.1.8.1.4 |
The temperature of sfp ransceiver transfer. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sfpVoltage |
1.3.6.1.4.1.35098.1.8.1.5 |
The voltage of sfp ransceiver transfer. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sfpBias |
1.3.6.1.4.1.35098.1.8.1.6 |
The bias current of sfp ransceiver transfer. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sfpTxPower |
1.3.6.1.4.1.35098.1.8.1.7 |
The Tx power of sfp ransceiver transfer(dBm). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sfpRxPower |
1.3.6.1.4.1.35098.1.8.1.8 |
The Rx power of sfp ransceiver transfer(dBm). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sfpType |
1.3.6.1.4.1.35098.1.8.1.9 |
The type of sfp ransceiver transfer(dBm). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
rpsustatusTable |
1.3.6.1.4.1.35098.1.9 |
A list of Redundancy power supply unit(RPSU) status entries. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
RpsustatusEntry |
|
rpsustatusEntry |
1.3.6.1.4.1.35098.1.9.1 |
An entry containing all Redundancy power supply unit(RPSU) stauts. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RpsustatusEntry |
|
|
rpsuIndex |
1.3.6.1.4.1.35098.1.9.1.1 |
The Redundancy power supply unit(RPSU) number. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..2147483647 |
|
rpsuStatus |
1.3.6.1.4.1.35098.1.9.1.2 |
The status of Redundancy power supply unit(RPSU).
1: The Redundancy power supply unit(RPSU) is plugged in.
0: The Redundancy power supply unit(RPSU) is plugged out. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
tftpConfigFilePath |
1.3.6.1.4.1.35098.2.0 |
If the tftp path of defined config file is set, the configurations
included in the config file are also applied meanwhile. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(2..255) |
|
tftpBatchFilePath |
1.3.6.1.4.1.35098.2.1 |
If the tftp path of a command batch file is set, the present configurations
will changed depending on the execution of the command in the batch file. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(2..255) |
|
picaGroups |
1.3.6.1.4.1.35098.20.1 |
OBJECT IDENTIFIER |
|
|
|
picaBasicGroup |
1.3.6.1.4.1.35098.20.1.1 |
These objects are required for pica private mib. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
picasfpGroup |
1.3.6.1.4.1.35098.20.1.2 |
These objects are required for pica private mib. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
picarpsuGroup |
1.3.6.1.4.1.35098.20.1.3 |
These objects are required for pica private mib. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
picaConfigGroup |
1.3.6.1.4.1.35098.20.1.4 |
These objects are required for pica private mib. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
picaCompliance |
1.3.6.1.4.1.35098.20.2.1 |
The compliance statement |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|