PDN-DS1CONFIG-MIB

File: PDN-DS1CONFIG-MIB.mib (13336 bytes)

Imported modules

RFC1213-MIB RFC1155-SMI RFC-1212
PDN-HEADER-MIB

Imported symbols

DisplayString Gauge OBJECT-TYPE
pdn-interfaces

Defined Types

DevDS1TestEntry  
SEQUENCE    
  devDS1TestIfIndex INTEGER
  devDS1TestType INTEGER
  devDS1TestControl INTEGER
  devDS1TestArgument DisplayString

DevDS1MonResultEntry  
SEQUENCE    
  devDS1MonResultIfIndex INTEGER
  devDS1MonResultTestType INTEGER
  devDS1MonResultCode INTEGER
  devDS1MonResultErrorCount Gauge

DevDS1SendControlEntry  
SEQUENCE    
  devDS1SendControlIfIndex INTEGER
  devDS1SendControlInjectErr INTEGER
  devDS1SendControlErrorCount Gauge

Defined Values

ent-ds1 1.3.6.1.4.1.1795.2.24.2.6.5
OBJECT IDENTIFIER    

devDS1Test 1.3.6.1.4.1.1795.2.24.2.6.5.1
OBJECT IDENTIFIER    

devDS1TestTable 1.3.6.1.4.1.1795.2.24.2.6.5.1.1
The Paradyne DS1 Interface Test Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DevDS1TestEntry

devDS1TestEntry 1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1
An entry in the Paradyne DS1 Interface Test Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DevDS1TestEntry  

devDS1TestIfIndex 1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.1
The index value which uniquely identifies the interface for which this entry contains information on interface tests. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex from the Interfaces table of MIB II (RFC 1213).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

devDS1TestType 1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.2
The index value which uniquely identifies the test for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER llbup(1), llbdn(2), llb(3), plb(4), rlb(5), sendQRSS(6), sendZeros(7), sendOnes(8), send1in8(9), send3in24(10), send63(11), send511(12), send2047(13), send2E15(14), send2E20(15), sendUserDefined(16), monQRSS(17), monZeros(18), monOnes(19), mon1in8(20), mon3in24(21), mon63(22), mon11(23), mon2047(24), mon2E15(25), mon2E20(26), monUserDefined(27), send2E7(28), mon2E7(29), send2E11(30), mon2E11(31)  

devDS1TestControl 1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.3
A control variable used to start and stop operator- initiated interface tests. Writing idle(1) to the test table entry terminates the specified test for the interface associated with the entry. Writing running(2) activates the specified test for the interface, if allowed (i.e., the test must be allowed for the interface and in combination with any other tests currently executing for the interface). The rules for executing tests for the product are specified in the product's Operator's Guide. This variable is read to determine the current status of the test for the interface. A value of running(2) indicates the test is currently in progress on the interface. A value of idle(1) indicates that the test is currently not active on the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER idle(1), running(2)  

devDS1TestArgument 1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.4
Any argument required by the test being executed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

devDS1MonResultTable 1.3.6.1.4.1.1795.2.24.2.6.5.1.2
The Paradyne Device Monitor Test Pattern Result Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DevDS1MonResultEntry

devDS1MonResultEntry 1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1
An entry in the Paradyne Device Monitor Test Pattern Result Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DevDS1MonResultEntry  

devDS1MonResultIfIndex 1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.1
The index value which uniquely identifies the interface for which this entry contains information on the result of the monitor test pattern request. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex from the Interfaces table of MIB II (RFC 1213).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

devDS1MonResultTestType 1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.2
The index value which uniquely identifies the test for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER monQRSS(17), monZeros(18), monOnes(19), mon1in8(20), mon3in24(21), mon63(22), mon11(23), mon2047(24), mon2E15(25), mon2E20(26), monUserDefined(27), mon2E7(29), mon2E11(31)  

devDS1MonResultCode 1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.3
This object contains a code for more specific information on the test pattern monitoring result. A value of none(1) indicates that no further information is available. inSyncNoBitErrors(2) notes that the monitor pattern test has synchronized on the pattern and has not detected any bit errors. inSyncWithBitErrors indicates that the monitor pattern test has synchronized on the pattern and has detected bit errors. A monitor pattern test that has not synchronized on the request pattern returns a value of notInSync(4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), inSyncNoBitErrors(2), inSyncWithBitErrors(3), notInSync(4)  

devDS1MonResultErrorCount 1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.4
The number of bit errors detected in the received monitoring test pattern. The error count is updated once every second. The error count does not increment during periods when the pattern is not synchronized, or once synchronization is lost. The maximum value of this object is 99,999. Writing any value to this object will reset it to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

devDS1SendControlTable 1.3.6.1.4.1.1795.2.24.2.6.5.1.3
The Paradyne Device Send Test Pattern Control Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DevDS1SendControlEntry

devDS1SendControlEntry 1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1
An entry in the Paradyne Device Send Test Pattern Control Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DevDS1SendControlEntry  

devDS1SendControlIfIndex 1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1.1
The index value which uniquely identifies the interface for which this entry contains information on the result of the monitor test pattern request. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex from the Interfaces table of MIB II (RFC 1213).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

devDS1SendControlInjectErr 1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1.2
Setting this object to inject(2) will inject one error in the data pattern being sent. If no pattern is being sent, the agent will return BAD VALUE. Reading this value will always return noOp(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOp(1), inject(2)  

devDS1SendControlErrorCount 1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1.3
The number of bit errors injected into the test pattern being sent. The maximum value of this object is 99,999.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge