PDN-CP-IWF-MIB
File:
PDN-CP-IWF-MIB.mib (44405 bytes)
Imported modules
Imported symbols
Defined Types
CpIwfRegion |
|
Different regions define an specific group of parameters |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
usa(1), canada(2) |
|
GatewayProtocol |
|
Gateway protocols supported by CPIWF running on this agent |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
lescas(1), voiceband(2), mgcp(3), sip(4) |
|
HookState |
|
This textual convention defines the different hook status for
POTS ports. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
onhook(1), offhook(2), ringground(3) |
|
PotsSignaling |
|
This textual convention defines the possible signaling types
for POTS ports.
|
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
loopstart(1), groundstart(2) |
|
ControlProtocol |
|
This textual convention defines the control protocol
capabilities of the CpIwf.
Each bit position in the bitmap corresponds to an
specific protocol. If the bit is 1, that protocol
is supported.
Bit 0 : cas (channel associated signaling)
Bit 1 : eoc (embedded operation channel)
Bit 2 : ccs/elcp (common signaling channel/
emulated loop control protocol)
Bit 3 : Not used (Future)
Bit 4 : Not used (Future)
Bit 5 : Not used (Future)
Bit 6 : Not used (Future)
Bit 7 : Not used (Future)
|
TEXTUAL-CONVENTION |
|
|
|
|
BITS |
cas(0), eoc(1), ccselcp(2) |
|
VoiceEncoding |
|
This textual convention defines the voice encoding
capabilities of the POTS port.
|
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
g711(0), g726(1), g729(2) |
|
PdnPotsTestTypes |
|
This textual convention defines the possible test
types for POTS ports.
|
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
noTest(1), loopback(2), ringsignal(3) |
|
PdnCpIwfEntry |
|
SEQUENCE |
|
|
|
|
pdnCpIwfIndex |
Integer32 |
|
|
pdnCpIwfIfIndex |
InterfaceIndex |
|
|
pdnCpIwfRowStatus |
RowStatus |
|
|
pdnCpIwfNumPotsAssigned |
Integer32 |
|
|
pdnCpIwfGatewayProtocol |
GatewayProtocol |
|
|
pdnCpIwfAtmBLESCapability |
ControlProtocol |
|
|
pdnCpIwfSscsPredefinedProfile |
Integer32 |
|
|
pdnCpIwfJitterBufferLength |
Integer32 |
|
PdnCpIwfMappingEntry |
|
SEQUENCE |
|
|
|
|
pdnCpIwfMappingIndex |
Integer32 |
|
PdnPotsPortEntry |
|
SEQUENCE |
|
|
|
|
pdnPotsPortIfIndex |
InterfaceIndex |
|
|
pdnPotsPortCpIwfIndex |
Integer32 |
|
|
pdnPotsPortHookStatus |
HookState |
|
|
pdnPotsPortSignalingMethod |
PotsSignaling |
|
|
pdnPotsPortTxGain |
Integer32 |
|
|
pdnPotsPortRxGain |
Integer32 |
|
|
pdnPotsPortCustInfo |
DisplayString |
|
|
pdnPotsPortG729VoiceCodec |
SwitchState |
|
|
pdnPotsPortPreferedVoiceCodec |
VoiceEncoding |
|
|
pdnPotsPortPreferredPacketPeriod |
Integer32 |
|
|
pdnPotsPortSilenceSuppression |
SwitchState |
|
|
pdnPotsPortActualVoiceCodec |
VoiceEncoding |
|
|
pdnPotsPortCallElapsedTime |
Integer32 |
|
|
pdnPotsPortModemDetected |
TruthValue |
|
|
pdnPotsPortEchoCanceller |
INTEGER |
|
|
pdnPotsPortLocalEndName |
DisplayString |
|
|
pdnPotsPortActiveSoftswitch |
INTEGER |
|
PdnCpIwfAal2StatsEntry |
|
SEQUENCE |
|
|
|
|
pdnCpIwfAal2CpsRxPkts |
Counter32 |
|
|
pdnCpIwfAal2CpsTxPkts |
Counter32 |
|
|
pdnCpIwfAal2CpsParityErrors |
Counter32 |
|
|
pdnCpIwfAal2CpsSeqNumErrors |
Counter32 |
|
|
pdnCpIwfAal2CpsOsfMismatchErrors |
Counter32 |
|
|
pdnCpIwfAal2CpsOsfErrors |
Counter32 |
|
|
pdnCpIwfAal2CpsHecErrors |
Counter32 |
|
|
pdnCpIwfAal2CpsOversizeSduErrors |
Counter32 |
|
|
pdnCpIwfAal2CpsReassemblyErrors |
Counter32 |
|
|
pdnCpIwfAal2CpsHecOverlapErrors |
Counter32 |
|
|
pdnCpIwfAal2CpsUuiErrors |
Counter32 |
|
|
pdnCpIwfAal2CpsCidErrors |
Counter32 |
|
PdnPotsPortStatsEntry |
|
SEQUENCE |
|
|
|
|
pdnPotsPortTotalCalls |
Counter32 |
|
|
pdnPotsPortTotalCallsFailure |
Counter32 |
|
|
pdnPotsPortTotalCallsDropped |
Counter32 |
|
|
pdnPotsPortInCallsReceived |
Counter32 |
|
|
pdnPotsPortInCallsAnswered |
Counter32 |
|
|
pdnPotsPortInCallsConnected |
Counter32 |
|
|
pdnPotsPortInCallsFailure |
Counter32 |
|
|
pdnPotsPortOutCallsAttempted |
Counter32 |
|
|
pdnPotsPortOutCallsAnswered |
Counter32 |
|
|
pdnPotsPortOutCallsConnected |
Counter32 |
|
|
pdnPotsPortOutCallsFailure |
Counter32 |
|
|
pdnPotsPortPacketsSent |
Counter32 |
|
|
pdnPotsPortPacketsReceived |
Counter32 |
|
|
pdnPotsPortPacketsLost |
Counter32 |
|
|
pdnPotsPortBytesSent |
Counter32 |
|
|
pdnPotsPortBytesReceived |
Counter32 |
|
PdnPotsTestEntry |
|
SEQUENCE |
|
|
|
|
pdnPotsTestType |
PdnPotsTestTypes |
|
|
pdnPotsTestCmd |
INTEGER |
|
|
pdnPotsTestStatus |
INTEGER |
|
Defined Values
pdnCpIwfMIB |
1.3.6.1.4.1.1795.2.24.2.50.1 |
This module defines a portion of the management information base (MIB)
for managing multiple Loop Emulation Service (LES) Customer Premises
Interworking Functions (CP-IWF). The mib recommended by the ATM forum
(af-vmoa-0145.000) lacks the ability to manage multiple CP-IWFs as
required by the Paradyne DSLAM products.
This enterprise mib is meant to be used in connection with RFC 2863
which defines the ifTable.
|
MODULE-IDENTITY |
|
|
|
pdnCpIwfTotalNumber |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.1 |
Indicates the total number of CpIwfs correctly configured
in this system.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2147483647 |
|
pdnCpIwfIndexNext |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.2 |
This object contains an appropriate value to
be used for pdnCpIwfIndex when creating
entries in the pdnCpIwfTable. The value
0 indicates that no unassigned entries are
available. To obtain the pdnCpIwfIndexNext
value for a new entry, the manager issues a
management protocol retrieval operation to obtain
the current value of this object. After each
retrieval, the agent should modify the value to
the next unassigned index.
After a manager retrieves a value the agent will
determine through its local policy when this index
value will be made available for reuse. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
pdnCpIwfRegion |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.3 |
This object permits the selection of a regional set of
parameters that apply to the entire device. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
CpIwfRegion |
|
|
pdnCpIwfTable |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4 |
The Cp-Iwf Configuration table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PdnCpIwfEntry |
|
pdnCpIwfEntry |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1 |
An entry in the Cp-Iwf configuration table.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PdnCpIwfEntry |
|
|
pdnCpIwfIndex |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.1 |
This object is an arbitrary index assigned by the agent.
When a client wishes to add an entry to this pdnCpIwfTable, first
it must do a get to the pdnCpIwfIndexNext and use the returned
value as the table's index for the new entry.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2147483647 |
|
pdnCpIwfIfIndex |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.2 |
This object displays the interface index from the ifTable
assigned by the SNMP agent upon creation of this CPIWF. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
pdnCpIwfRowStatus |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.3 |
rowStatus object that allows creation and deletion of CpIwfs. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
pdnCpIwfNumPotsAssigned |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.4 |
This object maintains the number of pots ports currently
assigned to this CpIwf.
It is not required that a new created CpIwf has Pots ports
assigned to it. Moreover, the default value for this object
can be implementation specific, for example:
- assign all 24 POTS ports to the CpIwf port upon creation.
- assign a minimum number of POTS to the CpIwf port.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..24 |
|
pdnCpIwfAtmBLESCapability |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.6 |
This object indicates whether this CP-IWF supports the
ATM Forum BLES standard with CCS and ELCP and EOC. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
ControlProtocol |
|
|
pdnCpIwfSscsPredefinedProfile |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.7 |
This object allows selection of predefined profiles for use by
voice/voiceband data connections using UUI codepoints 0-15 with
type 1 packets. The ATM Forum predefined profiles are specified
in Annex A: ATM Forum Predefined Profiles (see reference below).
Implementations are not required to support every profile. Thus,
an SNMP set on this object to an unsupported profile must result
in an SNMP Response with error status of badValue(3).
Examples of profiles and its attributes values:
<> (PCM-64, 44 Octet packets, without silence):
-------------------------------------------------------------------------------
UUI | Packet | Encoding | Description | | Packet | Seq.No
Codepoint | Length | Format | of | M | Time | Interval
Range | (octets) | Reference | Algorithm | | (ms) | (ms)
-------------------------------------------------------------------------------
0-15 44 Fig B-1/I.366.2 PCM, G.711-64, 1 5.5 5.5
Generic
<> (PCM-64 and ADPCM-32, 44 Octet packets, without silence):
-------------------------------------------------------------------------------
UUI | Packet | Encoding | Description | | Packet | Seq.No
Codepoint | Length | Format | of | M | Time | Interval
Range | (octets) | Reference | Algorithm | | (ms) | (ms)
-------------------------------------------------------------------------------
0-7 44 Fig B-1/I.366.2 PCM, G.711-64, 1 5.5 5.5
Generic
7-15 44 Fig E-2/I.366.2 ADPCM, G.726-32 1 5.5 5.5
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnCpIwfJitterBufferLength |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.8 |
This object allows the configuration of the jitter buffer
length. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
10..120 |
|
pdnCpIwfMappingTable |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.5 |
A table mapping the 'ifIndex' values of 'pdnCpIwfIfIndex'
to the 'pdnCpIwfIndex' values of the corresponding CpIwf. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PdnCpIwfMappingEntry |
|
pdnCpIwfMappingEntry |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.5.1 |
Each row describes the mapping of one ifIndex to a pdnCpIwfIndex. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PdnCpIwfMappingEntry |
|
|
pdnCpIwfMappingIndex |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.5.1.1 |
The index assigned to the Cp-Iwf's interface upon creation. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2147483647 |
|
pdnPotsPortTable |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6 |
The Pots port Configuration table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PdnPotsPortEntry |
|
pdnPotsPortEntry |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1 |
An entry in the Pots Port configuration table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PdnPotsPortEntry |
|
|
pdnPotsPortIfIndex |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.1 |
ifIndex value from ifTable for this POTS port. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
pdnPotsPortCpIwfIndex |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.2 |
The value of this object corresponds to a valid
pdnCpIwfIndex in the pdnCpIwfTable or '0' which has
the meaning of 'not-assigned'.
The value 0 is expected to be used during changes on the
assignment of Pots ports, that is, a Pots port initially
assigned to a CpIwf port needs to be un-assigned first and
then assigned to the new CpIwf Port.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
pdnPotsPortHookStatus |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.3 |
Current hook status of this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
HookState |
|
|
pdnPotsPortTxGain |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.5 |
This is the gain in the analog-to-digital direction
(towards the uplink).
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-24..23 |
|
pdnPotsPortRxGain |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.6 |
This is the gain in the digital-to-analog direction
(towards the loop).
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-24..23 |
|
pdnPotsPortCustInfo |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.7 |
This object represents textual information about
an user, typically user name and directory number.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
pdnPotsPortG729VoiceCodec |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.8 |
This object is used to enable or disable G.729 codec
on this POTS port.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
SwitchState |
|
|
pdnPotsPortPreferredPacketPeriod |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.10 |
The value of this object contains the preferred
packetization period in milliseconds.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
pdnPotsPortSilenceSuppression |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.11 |
This object allows users to enable or disable silence
suppression. If the value of the object is 'enabled (1)'
silence suppression will be performed for a call placed
on this port if agreed via negotiation with the far end.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
SwitchState |
|
|
pdnPotsPortActualVoiceCodec |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.12 |
This object is the actual voice encoding being used on
this port as determined by the device in real-time.
This object may differ from the configurable
'pdnPotsPortPreferedVoiceCodec' object.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
VoiceEncoding |
|
|
pdnPotsPortCallElapsedTime |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.13 |
This value is the number of seconds that have elapsed
since the start of the current call.
If no active call is in progress on this port, this
object should be zero.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..65535 |
|
pdnPotsPortModemDetected |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.14 |
This object displays the status of the modem/fax
connected on this port. If the value of this object
is 'enabled (1)' the modem or fax answer tone has
been detected. Otherwise this object will return
'disabled (2)'.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
pdnPotsPortEchoCanceller |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.15 |
This object displays the current status of the
echo canceller.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
pdnPotsPortLocalEndName |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.16 |
This object contains a descriptive text
identifying the local endpoint's name.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..64) |
|
pdnPotsPortActiveSoftswitch |
1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.17 |
This object displays the active selection for the
Softswitch (e.g., Call Agent, Proxy Agent, etc.)
for this Pots port.
The possible values for this object are:
primary --> Primary Softswitch is selected
secondary --> Secondary Softswitch is selected
none --> no softswitch is currently selected.
The configuration of the primary/secondary softswitches
are found in objects outside this document
(e.g., pdnCpIwfIpMgcpPriAgentName, etc...)
If the SNMP agent can not determine an active
softswitch for this Pots port (e.g, lost communication
with the Call Agent), the value of this object will be
set to 'none (3)'.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
primary(1), secondary(2), none(3) |
|
pdnCpIwfAal2StatsTable |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1 |
This table is used to maintain AAL2-Customer Part Sublayer (CPS)
statistics per VCC associated to each CpIwf port.
An entry in this table represents the AAL2 statistics maintained
for this circuit.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PdnCpIwfAal2StatsEntry |
|
pdnCpIwfAal2StatsEntry |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1 |
Contained AAL2 stats for a VCC defined on this cpIwf. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PdnCpIwfAal2StatsEntry |
|
|
pdnCpIwfAal2CpsParityErrors |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.3 |
Number of errors encountered as specified in Table 6/I.363.2
(errnum=0) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnCpIwfAal2CpsSeqNumErrors |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.4 |
Number of errors encountered as specified in Table 6/I.363.2
(errnum=1) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnCpIwfAal2CpsOsfErrors |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.6 |
Number of errors encountered as specified in Table 6/I.363.2
(errnum=3) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnCpIwfAal2CpsHecErrors |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.7 |
Number of errors encountered as specified in Table 6/I.363.2
(errnum=4) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnCpIwfAal2CpsUuiErrors |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.11 |
Number of errors encountered as specified in Table 6/I.363.2
(errnum=8) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnCpIwfAal2CpsCidErrors |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.12 |
Number of errors encountered as specified in Table 6/I.363.2
(errnum=9) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortStatsEntry |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1 |
Contained statistics per Pots Port. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PdnPotsPortStatsEntry |
|
|
pdnPotsPortTotalCalls |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.1 |
Total Number of successfull calls performed on this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortTotalCallsDropped |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.3 |
Total number of calls (in/out) that were dropped on
this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortInCallsReceived |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.4 |
Total number of incoming calls received on this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortInCallsAnswered |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.5 |
Total number of incoming calls answered on this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortInCallsConnected |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.6 |
Total number of incoming calls connected on this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortInCallsFailure |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.7 |
Total number of incoming calls that failed on this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortOutCallsAttempted |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.8 |
Total number of outgoing calls that were attempted on
this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortOutCallsAnswered |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.9 |
Total number of outgoing calls that were answered on
this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortOutCallsConnected |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.10 |
Total number of outgoing calls that were connected on
this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortOutCallsFailure |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.11 |
Total number of outgoing calls that failed on
this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortPacketsSent |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.12 |
Total number of packets transmitted by this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortPacketsLost |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.14 |
Total number of packets lost by this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortBytesSent |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.15 |
Total number of bytes transmitted by this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsPortBytesReceived |
1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.16 |
Total number of bytes received by this POTS port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
pdnPotsTestTable |
1.3.6.1.4.1.1795.2.24.2.50.1.1.2.1 |
The Paradyne Pots Port Interface Test Table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PdnPotsTestEntry |
|
pdnPotsTestEntry |
1.3.6.1.4.1.1795.2.24.2.50.1.1.2.1.1 |
An entry in the Paradyne POTS Interface Test Table.
Only 1 test can be run at a time per POTS interface
index (ifIndex).
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PdnPotsTestEntry |
|
|
pdnPotsTestType |
1.3.6.1.4.1.1795.2.24.2.50.1.1.2.1.1.1 |
This object is used to specify the test type
in this interface.
If no test is active on this port, the agent
should return the value of 'noTest (1)'
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
PdnPotsTestTypes |
|
|
pdnPotsTestCmd |
1.3.6.1.4.1.1795.2.24.2.50.1.1.2.1.1.2 |
This object can be set to initiate and/or terminate
the test running on this interface.
If no test is 'active' on this interface, the agent
should return the value of 'noOp(1)'.
Only if a test is 'active' on this interface, the
agent should process a 'keepAlive (4)' command.
Otherwise, this command should be rejected.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noOp(1), start(2), stop(3), keepAlive(4) |
|
pdnPotsTestStatus |
1.3.6.1.4.1.1795.2.24.2.50.1.1.2.1.1.3 |
This object displays the current status of this entry.
If no test is running on this interface, the agent
should return the value 'inactive (2)'.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
active(1), inactive(2) |
|
pdnCpIwfMIBCompliance |
1.3.6.1.4.1.1795.2.24.2.50.1.2.1.1 |
The compliance statement for SNMP entities that support LES
as specified in af-vmoa-0145.000 of the ATM Forum.
This compliance has been deprecated and replaced by V2 below.
|
Status: deprecated |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
pdnCpIwfMIBComplianceV2 |
1.3.6.1.4.1.1795.2.24.2.50.1.2.1.2 |
The compliance statement for SNMP entities that support LES
as specified in af-vmoa-0145.000 of the ATM Forum.
This compliance statement superseeds the pdnCpIwfMIBCompliance.
This compliance has been deprecated and replaced by V3 below.
|
Status: deprecated |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
pdnCpIwfMIBComplianceV3 |
1.3.6.1.4.1.1795.2.24.2.50.1.2.1.3 |
The compliance statement for SNMP entities that support LES
as specified in af-vmoa-0145.000 of the ATM Forum.
This compliance statement superseeds the pdnCpIwfMIBComplianceV2.
|
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
pdnCpIwfGeneralConfigGroup |
1.3.6.1.4.1.1795.2.24.2.50.1.2.2.1 |
General Configuration of CpIwf ports |
Status: deprecated |
Access: read-only |
OBJECT-GROUP |
|
|
|
pdnCpIwfPotsPortConfigGroup |
1.3.6.1.4.1.1795.2.24.2.50.1.2.2.2 |
Configuration group for Pots ports
This group is now deprecated by
pdnCpIwfPotsPortConfigGroupV2.
|
Status: deprecated |
Access: read-only |
OBJECT-GROUP |
|
|
|
pdnCpIwfAal2StatsGroup |
1.3.6.1.4.1.1795.2.24.2.50.1.2.2.3 |
Aal2 stats per CpIwf |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
pdnCpIwfPotsPortStatsGroup |
1.3.6.1.4.1.1795.2.24.2.50.1.2.2.4 |
Pots Ports stats group |
Status: deprecated |
Access: read-only |
OBJECT-GROUP |
|
|
|
pdnCpIwfGeneralConfigGroupV2 |
1.3.6.1.4.1.1795.2.24.2.50.1.2.2.5 |
Configuration of general parameters related to the CpIwf.
This group superseeds the pdnCpIwfGeneralConfigGroup
which was splitted in two groups. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
pdnCpIwfIADConfigGroupV2 |
1.3.6.1.4.1.1795.2.24.2.50.1.2.2.6 |
Configuration of each CpIwf interfaces in the device.
This group superseeds the pdnCpIwfGeneralConfigGroup
which was splitted in two groups.
This group is now deprecated by
pdnCpIwfPotsPortConfigGroupV3. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
pdnCpIwfPotsPortConfigGroupV2 |
1.3.6.1.4.1.1795.2.24.2.50.1.2.2.8 |
Configuration group for Pots ports |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
pdnCpIwfIADConfigGroupV3 |
1.3.6.1.4.1.1795.2.24.2.50.1.2.2.10 |
Configuration of each CpIwf interfaces in the device.
This group superseeds the pdnCpIwfGeneralConfigGroupV2.
|
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|