PCE-MIB

File: PCE-MIB.mib (1864287 bytes)

Imported modules

RFC-1215 RFC1155-SMI RFC1213-MIB

Imported symbols

TRAP-TYPE enterprises OBJECT-TYPE
NetworkAddress IpAddress Counter
Gauge TimeTicks DisplayString
PhysAddress

Defined Types

FcCtlAlteredLpEntry  
SEQUENCE    
  fcCtlAlteredLpId INTEGER

FcCtlAlteredDlciEntry  
SEQUENCE    
  fcCtlAlteredDlciPpId INTEGER
  fcCtlAlteredDlciNum INTEGER
  fcCtlAlteredDlciState INTEGER

FcCtlAlteredIfEntry  
SEQUENCE    
  fcCtlAlteredIfId INTEGER

FcCtlErrorEntry  
SEQUENCE    
  fcCtlErrorIndex INTEGER
  fcCtlErrorCode INTEGER
  fcCtlErrorMessage DisplayString
  fcCtlErrorTime TimeTicks

FcCtlHRCheckMessagesEntry  
SEQUENCE    
  fcCtlHRCheckMsgIndex INTEGER
  fcCtlHRCheckMsgCode OCTET STRING
  fcCtlHRCheckMessage DisplayString

FcsModuleEntry  
SEQUENCE    
  fcsModuleId INTEGER
  fcsModuleSubscriberNumber OCTET STRING
  fcsModuleBridgeInit INTEGER
  fcsModuleIpxRouterInit INTEGER
  fcsModuleClnpRouterInit INTEGER

FcmMgtFctActivationEntry  
SEQUENCE    
  fcmMgfActName INTEGER
  fcmMgfActAdminStatus INTEGER
  fcmMgfActPassword DisplayString

FcmMgtFctCugEntry  
SEQUENCE    
  fcmMgtFctCugFunctionId INTEGER
  fcmMgtFctCugGroupId INTEGER
  fcmMgtFctCugClosedUserGroupExt INTEGER
  fcmMgtFctCugClosedUserGroupInt INTEGER
  fcmMgtFctCugChecking INTEGER

FcmAlrmEventEntry  
SEQUENCE    
  fcmAlrmEvtFamilyId INTEGER
  fcmAlrmEvtEventSelection INTEGER
  fcmAlrmEvtEvent1 OCTET STRING
  fcmAlrmEvtEvent2 OCTET STRING
  fcmAlrmEvtEvent3 OCTET STRING
  fcmAlrmEvtEvent4 OCTET STRING
  fcmAlrmEvtEvent5 OCTET STRING
  fcmAlrmEvtEvent6 OCTET STRING
  fcmAlrmEvtEvent7 OCTET STRING

FcmAlrmPhysPortEntry  
SEQUENCE    
  fcmAlrmPpFamilyId INTEGER
  fcmAlrmPpPhysPortSelection INTEGER
  fcmAlrmPpPhysPort1 INTEGER
  fcmAlrmPpPhysPort2 INTEGER
  fcmAlrmPpPhysPort3 INTEGER
  fcmAlrmPpPhysPort4 INTEGER
  fcmAlrmPpPhysPort5 INTEGER
  fcmAlrmPpPhysPort6 INTEGER
  fcmAlrmPpPhysPort7 INTEGER

FcfPhysicalPortEntry  
SEQUENCE    
  fcfPhysPortId INTEGER
  fcfPhysPortConnector INTEGER
  fcfInterfaceType INTEGER

FcfLineEntry  
SEQUENCE    
  fcfLineInterfaceId INTEGER
  fcfLineType INTEGER
  fcfLineModemManagement INTEGER
  fcfLineSpeed INTEGER
  fcfLineLinkCheckPeriod INTEGER
  fcfLineCheckPeriodCount INTEGER

FcfLineV28AsynOutDteSignalEntry  
SEQUENCE    
  fcfLineV28AsynOutDteInterfaceId INTEGER
  fcfLineV28AsynOutDteRts105 INTEGER
  fcfLineV28AsynOutDteDtr108 INTEGER
  fcfLineV28AsynOutDteDrs111 INTEGER
  fcfLineV28AsynOutDteRil140 INTEGER
  fcfLineV28AsynOutDteLl141 INTEGER

FcfLineV28AsynOutDceSignalEntry  
SEQUENCE    
  fcfLineV28AsynOutDceInterfaceId INTEGER
  fcfLineV28AsynOutDceCts106 INTEGER
  fcfLineV28AsynOutDceDsr107 INTEGER
  fcfLineV28AsynOutDceDcd109 INTEGER
  fcfLineV28AsynOutDceSi117 INTEGER
  fcfLineV28AsynOutDceTi142 INTEGER

FcfLineV28AsynInDteSignalEntry  
SEQUENCE    
  fcfLineV28AsynInDteInterfaceId INTEGER
  fcfLineV28AsynInDteEnablingSig1 INTEGER
  fcfLineV28AsynInDteEnablingSig2 INTEGER
  fcfLineV28AsynInDteSigMonitored1 INTEGER
  fcfLineV28AsynInDteSigMonitored2 INTEGER

FcfLineV28AsynInDceSignalEntry  
SEQUENCE    
  fcfLineV28AsynInDceInterfaceId INTEGER
  fcfLineV28AsynInDceEnablingSig1 INTEGER
  fcfLineV28AsynInDceEnablingSig2 INTEGER
  fcfLineV28AsynInDceSigMonitored1 INTEGER
  fcfLineV28AsynInDceSigMonitored2 INTEGER

FcfLineV28DteSignalEntry  
SEQUENCE    
  fcfLineV28DteInterfaceId INTEGER
  fcfLineV28DteCts106 INTEGER
  fcfLineV28DteDsr107 INTEGER
  fcfLineV28DteDcd109 INTEGER
  fcfLineV28DteSi117 INTEGER
  fcfLineV28DteTi142 INTEGER
  fcfLineV28DteSyn INTEGER

FcfLineV28DceSignalEntry  
SEQUENCE    
  fcfLineV28DceInterfaceId INTEGER
  fcfLineV28DceRts105 INTEGER
  fcfLineV28DceDtr108 INTEGER
  fcfLineV28DceDrs111 INTEGER
  fcfLineV28DceRil140 INTEGER
  fcfLineV28DceLl141 INTEGER
  fcfLineV28DceSyn INTEGER

FcfLineV11DteSignalEntry  
SEQUENCE    
  fcfLineV11DteInterfaceId INTEGER
  fcfLineV11DteIndication109 INTEGER
  fcfLineV11DteSyn INTEGER

FcfLineV11DceSignalEntry  
SEQUENCE    
  fcfLineV11DceInterfaceId INTEGER
  fcfLineV11DceControl105 INTEGER
  fcfLineV11DceSyn INTEGER

FcfLineV35DteSignalEntry  
SEQUENCE    
  fcfLineV35DteInterfaceId INTEGER
  fcfLineV35DteD106 INTEGER
  fcfLineV35DteE107 INTEGER
  fcfLineV35DteF109 INTEGER
  fcfLineV35DteTi142 INTEGER
  fcfLineV35DteSyn INTEGER

FcfLineV35DceSignalEntry  
SEQUENCE    
  fcfLineV35DceInterfaceId INTEGER
  fcfLineV35DceC105 INTEGER
  fcfLineV35DceH108 INTEGER
  fcfLineV35DceRil140 INTEGER
  fcfLineV35DceLl141 INTEGER
  fcfLineV35DceSyn INTEGER

FcfLineModemEntry  
SEQUENCE    
  fcfLineModInterfaceId INTEGER
  fcfLineModType INTEGER
  fcfLineModLinkUpTimer INTEGER
  fcfLineModNewDiallingTimer INTEGER
  fcfLineModDiallingCount INTEGER
  fcfLineModUnuseTimer INTEGER
  fcfLineModSpeed INTEGER
  fcfLineModCallDirection INTEGER
  fcfLineModInitString DisplayString
  fcfLineModOutputXidString INTEGER
  fcfLineModOutputXidStringId INTEGER
  fcfLineModInputXidString INTEGER
  fcfLineModInputXidStringCount INTEGER

FcfLineModXidStringEntry  
SEQUENCE    
  fcfLineModXidStringId INTEGER
  fcfLineModXidStringEltNum INTEGER
  fcfLineModXidStringEltStatus INTEGER
  fcfLineModXidStringElement OCTET STRING

FcfLineDVBEntry  
SEQUENCE    
  fcfLineDVBInterfaceId INTEGER
  fcfLineDVBStatus INTEGER
  fcfLineDVBConnection INTEGER

FcfIsdnBasicRateInterfaceEntry  
SEQUENCE    
  fcfIsdnBasicRateInterfaceId INTEGER
  fcfIsdnBriSignalling INTEGER
  fcfIsdnBriCountry INTEGER
  fcfIsdnBriInterfaceCheckPeriod INTEGER
  fcfIsdnBriFilterRepeatCount INTEGER
  fcfIsdnBriEnablingTimer INTEGER
  fcfIsdnBriDisablingTimer INTEGER

FcfIsdnPrimaryRateInterfaceEntry  
SEQUENCE    
  fcfIsdnPrimaryRateInterfaceId INTEGER
  fcfIsdnPriSignalling INTEGER
  fcfIsdnPriCountry INTEGER
  fcfIsdnPriINbBChannel INTEGER
  fcfIsdnPriCrc4 INTEGER

FcfIsdnDChannelSignallingEntry  
SEQUENCE    
  fcfIsdnDSigIsdnInterfaceId INTEGER
  fcfIsdnDSigIsdnNumber OCTET STRING
  fcfIsdnDSigUnuseTimer INTEGER
  fcfIsdnDSigCalledSubAddressCheck INTEGER
  fcfIsdnDSigDirectInwardDialingCheck INTEGER
  fcfIsdnDSigInactivityTimer INTEGER
  fcfIsdnDSigMulDialsRetryTimer INTEGER
  fcfIsdnDSigMulDialsCycleTimer INTEGER
  fcfIsdnDSigMulDialsCycleCount INTEGER
  fcfIsdnDSigMulDialsTotalDuration INTEGER
  fcfIsdnDSigLowLayerCompatibility INTEGER
  fcfIsdnDSigHighLayerCompatibility INTEGER
  fcfIsdnDSigHighLayerCharactIdent INTEGER

FcfIsdnDChannelSigTimerEntry  
SEQUENCE    
  fcfIsdnDTimIsdnInterfaceId INTEGER
  fcfIsdnDTimBChannelUpTimer INTEGER
  fcfIsdnDTimT301AlertConnectTimer INTEGER
  fcfIsdnDTimT303SetupResponseTimer INTEGER
  fcfIsdnDTimT305DisconnectResponseTimer INTEGER
  fcfIsdnDTimT308ReleaseResponseTimer INTEGER
  fcfIsdnDTimT309DataLinkFailureTimer INTEGER
  fcfIsdnDTimT310CallProceedingTimer INTEGER
  fcfIsdnDTimT313ConnectAcknowledgeTimer INTEGER

FcfIsdnRemotePeerEntry  
SEQUENCE    
  fcfIsdnRemRemotePeerId INTEGER
  fcfIsdnRemStatus INTEGER
  fcfIsdnRemIsdnNumber OCTET STRING
  fcfIsdnRemCallDirection INTEGER

FcfE1Ds1PhysEntry  
SEQUENCE    
  fcfE1Ds1PhysIfId INTEGER
  fcfE1Ds1PhysStatus INTEGER
  fcfE1Ds1PhysPhysicalPort INTEGER

FcfE1PhysPortEntry  
SEQUENCE    
  fcfE1PhysPortId INTEGER
  fcfE1PhysPortSynchSrc INTEGER
  fcfE1PhysPortFraming INTEGER
  fcfE1PhysPortFlowType INTEGER

FcfE1Ds1ChannelEntry  
SEQUENCE    
  fcfE1Ds1ChannelIfId INTEGER
  fcfE1Ds1ChannelStatus INTEGER
  fcfE1Ds1ChannelPhysIf INTEGER
  fcfE1Ds1ChannelSlots DisplayString

FcfE1Ds1DropInsertEntry  
SEQUENCE    
  fcfE1Ds1DropInsertIf1 INTEGER
  fcfE1Ds1DropInsertIf2 INTEGER
  fcfE1Ds1DropInsertStatus INTEGER

FcfTokenRingEntry  
SEQUENCE    
  fcfTokenRingInterfaceId INTEGER
  fcfTokenRingSpeed INTEGER
  fcfTokenRingLinkCheckPeriod INTEGER
  fcfTokenRingCheckPeriodCount INTEGER

FcFrSwitchingEntry  
SEQUENCE    
  fcFrSwInputInterfaceId INTEGER
  fcFrSwInputDlci INTEGER
  fcFrSwStatus INTEGER
  fcFrSwOutputInterfaceId INTEGER
  fcFrSwOutputDlci INTEGER
  fcFrSwPriority INTEGER

FclLogicalPortEntry  
SEQUENCE    
  fclLogPortId INTEGER
  fclLogPortStatus INTEGER
  fclLogPortType INTEGER

FclEthernetEntry  
SEQUENCE    
  fclEthLogPortId INTEGER
  fclEthInterfaceId INTEGER

FclAsynLogPortEntry  
SEQUENCE    
  fclAsynLpLogPortId INTEGER
  fclAsynLpInterfaceId INTEGER
  fclAsynLpSubscriberNumber OCTET STRING
  fclAsynLpConfigId INTEGER
  fclAsynLpTerminalType INTEGER

FclAsynPadLpEntry  
SEQUENCE    
  fclAsynPadLpLogPortId INTEGER
  fclAsynPadLpLink INTEGER
  fclAsynPadLpSpeedDetection INTEGER
  fclAsynPadLpEquipment INTEGER
  fclAsynPadLpMnemonicType INTEGER
  fclAsynPadLpNui INTEGER
  fclAsynPadLpCombinedFlowCtrl INTEGER

FclAsynPadHomePageEntry  
SEQUENCE    
  fclAsynPadPageBlocId INTEGER
  fclAsynPadPageStatus INTEGER
  fclAsynPadPageMessage DisplayString
  fclAsynPadPageAttributes OCTET STRING

FclAsynVdxLpEntry  
SEQUENCE    
  fclAsynVdxLpLogPortId INTEGER
  fclAsynVdxLpLink INTEGER
  fclAsynVdxLpMnemonicType INTEGER
  fclAsynVdxLpNui INTEGER
  fclAsynVdxLpParityBit INTEGER
  fclAsynVdxLpPceSubThreshold INTEGER
  fclAsynVdxLpPceNackTimer INTEGER

FclAsynVdxHomePageEntry  
SEQUENCE    
  fclAsynVdxPageBlocId INTEGER
  fclAsynVdxPageStatus INTEGER
  fclAsynVdxPageMessage DisplayString
  fclAsynVdxPageAttributes OCTET STRING

FclAsynLscpLpEntry  
SEQUENCE    
  fclAsynLscpLpLogPortId INTEGER
  fclAsynLscpLpLink INTEGER
  fclAsynLscpLpEquipment INTEGER

FclAsynMultiLpEntry  
SEQUENCE    
  fclAsynMultiLpLogPortId INTEGER
  fclAsynMultiLpAuthStep1 INTEGER
  fclAsynMultiLpAuthStep2 INTEGER
  fclAsynMultiLpAuthStep3 INTEGER
  fclAsynMultiLpAuthStep4 INTEGER

FclAsynX28PlusLpEntry  
SEQUENCE    
  fclAsynX28PlusLpLogPortId INTEGER
  fclAsynX28PlusLpLink INTEGER
  fclAsynX28PlusLpSpeedDetection INTEGER
  fclAsynX28PlusLpEquipment INTEGER
  fclAsynX28PlusLpMnemonicType INTEGER
  fclAsynX28PlusLpFullDuplex INTEGER
  fclAsynX28PlusLpIdleTimerSelection INTEGER
  fclAsynX28PlusLpIdleTimerDelay INTEGER
  fclAsynX28PlusLpX3Mode INTEGER
  fclAsynX28PlusLpEscapeDigit INTEGER
  fclAsynX28PlusLpConIdTelenet INTEGER
  fclAsynX28PlusLpConIdRemote INTEGER
  fclAsynX28PlusLpRemPrSentOnCalls INTEGER
  fclAsynX28PlusLpEasyMnemo INTEGER
  fclAsynX28PlusLpMonSignalCTS INTEGER
  fclAsynX28PlusLpMonSignalDSR INTEGER
  fclAsynX28PlusLpMonSignalDCD INTEGER

FclAsynX28PlusConfTELENETEntry  
SEQUENCE    
  fclAsynX28PlusCfgTELENETConfigId INTEGER
  fclAsynX28PlusCfgTELENETDescription DisplayString

FclAsynX28PlusParTELENETEntry  
SEQUENCE    
  fclAsynX28PlusParTelConfigId INTEGER
  fclAsynX28PlusParTelLpFullDuplex INTEGER
  fclAsynX28PlusParTelLpIdleTimerSelection INTEGER
  fclAsynX28PlusParTelLpIdleTimerDelay INTEGER
  fclAsynX28PlusParTelLpX3Mode INTEGER

FclAsynX28PlusConfRemoteEntry  
SEQUENCE    
  fclAsynX28PlusRemoteConfigId INTEGER
  fclAsynX28PlusRemoteCfgDescription DisplayString

FclAsynX28PlusRemoteCfgX3Part1Entry  
SEQUENCE    
  fclAsynX28PlusRemConfigId INTEGER
  fclAsynX28PlusRemCfgX3P01EscapeChar INTEGER
  fclAsynX28PlusRemCfgX3P02Echo INTEGER
  fclAsynX28PlusRemCfgX3P03ForwardingChar INTEGER
  fclAsynX28PlusRemCfgX3P04IdleTimerDelay INTEGER
  fclAsynX28PlusRemCfgX3P05OutputFlowCtrl INTEGER
  fclAsynX28PlusRemCfgX3P06ServiceSignals INTEGER
  fclAsynX28PlusRemCfgX3P07BreakHandling INTEGER
  fclAsynX28PlusRemCfgX3P08OutputDiscard INTEGER
  fclAsynX28PlusRemCfgX3P09CrPadding INTEGER
  fclAsynX28PlusRemCfgX3P10LineFolding INTEGER
  fclAsynX28PlusRemCfgX3P11BinarySpeed INTEGER

FclAsynX28PlusRemoteCfgX3Part2Entry  
SEQUENCE    
  fclAsynX28PlusRemCfgX3Part2ConfigId INTEGER
  fclAsynX28PlusRemCfgX3P12InputFlowCtrl INTEGER
  fclAsynX28PlusRemCfgX3P13LfInsertion INTEGER
  fclAsynX28PlusRemCfgX3P14LfPadding INTEGER
  fclAsynX28PlusRemCfgX3P15Editing INTEGER
  fclAsynX28PlusRemCfgX3P16CharDelete INTEGER
  fclAsynX28PlusRemCfgX3P17LineDelete INTEGER
  fclAsynX28PlusRemCfgX3P18LineDisplay INTEGER
  fclAsynX28PlusRemCfgX3P19EditingSignal INTEGER
  fclAsynX28PlusRemCfgX3P20EchoMask INTEGER
  fclAsynX28PlusRemCfgX3P21Parity INTEGER
  fclAsynX28PlusRemCfgX3P22PageWait INTEGER

FclAsynX28PlusRemoteTELENETEntry  
SEQUENCE    
  fclAsynX28PlusRemCfgTELENETConfigId INTEGER
  fclAsynX28PlusRemLpFullDuplex INTEGER
  fclAsynX28PlusRemLpIdleTimerSelection INTEGER
  fclAsynX28PlusRemLpIdleTimerDelay INTEGER
  fclAsynX28PlusRemLpX3Mode INTEGER

FclAsynCfgConfigEntry  
SEQUENCE    
  fclAsynCfgConfigId INTEGER
  fclAsynCfgStatus INTEGER
  fclAsynCfgDescription DisplayString
  fclAsynCfgX3ProfileId INTEGER
  fclAsynCfgX3ModifCount INTEGER
  fclAsynCfgConnectionProfileId INTEGER
  fclAsynCfgConnModifCount INTEGER

FclAsynCfgX3Part1Entry  
SEQUENCE    
  fclAsynCfgX3Part1ConfigId INTEGER
  fclAsynCfgX3Part1ProfileId INTEGER
  fclAsynCfgX3P01EscapeChar INTEGER
  fclAsynCfgX3P02Echo INTEGER
  fclAsynCfgX3P03ForwardingChar INTEGER
  fclAsynCfgX3P04IdleTimerDelay INTEGER
  fclAsynCfgX3P05OutputFlowCtrl INTEGER
  fclAsynCfgX3P06ServiceSignals INTEGER
  fclAsynCfgX3P07BreakHandling INTEGER
  fclAsynCfgX3P08OutputDiscard INTEGER
  fclAsynCfgX3P09CrPadding INTEGER
  fclAsynCfgX3P10LineFolding INTEGER
  fclAsynCfgX3P11BinarySpeed INTEGER

FclAsynCfgX3Part2Entry  
SEQUENCE    
  fclAsynCfgX3Part2ConfigId INTEGER
  fclAsynCfgX3Part2ProfileId INTEGER
  fclAsynCfgX3P12InputFlowCtrl INTEGER
  fclAsynCfgX3P13LfInsertion INTEGER
  fclAsynCfgX3P14LfPadding INTEGER
  fclAsynCfgX3P15Editing INTEGER
  fclAsynCfgX3P16CharDelete INTEGER
  fclAsynCfgX3P17LineDelete INTEGER
  fclAsynCfgX3P18LineDisplay INTEGER
  fclAsynCfgX3P19EditingSignal INTEGER
  fclAsynCfgX3P20EchoMask INTEGER
  fclAsynCfgX3P21Parity INTEGER
  fclAsynCfgX3P22PageWait INTEGER

FclAsynCfgConnLinkEntry  
SEQUENCE    
  fclAsynCfgLinkConfigId INTEGER
  fclAsynCfgLinkXonXoffParity INTEGER
  fclAsynCfgLinkServSignalParity INTEGER
  fclAsynCfgLinkDataParity INTEGER
  fclAsynCfgLinkBitCount INTEGER
  fclAsynCfgLinkStopBitCount INTEGER
  fclAsynCfgLinkXonXoffSignal INTEGER
  fclAsynCfgLinkInactivityTimer INTEGER
  fclAsynCfgLinkBlockSize INTEGER
  fclAsynCfgLinkCallResponseTimer INTEGER

FclAsynCfgConnFacilityEntry  
SEQUENCE    
  fclAsynCfgFacConfigId INTEGER
  fclAsynCfgFacClosedUserGroup INTEGER
  fclAsynCfgFacReverseCharging INTEGER
  fclAsynCfgFacThroughputClass INTEGER
  fclAsynCfgFacDefOutThroughputClass INTEGER
  fclAsynCfgFacDefInThroughputClass INTEGER
  fclAsynCfgFacMaxOutThroughputClass INTEGER
  fclAsynCfgFacMaxInThroughputClass INTEGER
  fclAsynCfgFacPacketSize INTEGER
  fclAsynCfgFacDefOutPacketSize INTEGER
  fclAsynCfgFacDefInPacketSize INTEGER
  fclAsynCfgFacMaxOutPacketSize INTEGER
  fclAsynCfgFacMaxInPacketSize INTEGER
  fclAsynCfgFacMinOutPacketSize INTEGER
  fclAsynCfgFacMinInPacketSize INTEGER
  fclAsynCfgFacWindowSize INTEGER
  fclAsynCfgFacDefOutWindowSize INTEGER
  fclAsynCfgFacDefInWindowSize INTEGER
  fclAsynCfgFacMaxOutWindowSize INTEGER
  fclAsynCfgFacMaxInWindowSize INTEGER

FclAsynCfgConnServiceEntry  
SEQUENCE    
  fclAsynCfgSerConfigId INTEGER
  fclAsynCfgSerCompression INTEGER
  fclAsynCfgSerCompressNegociation INTEGER
  fclAsynCfgSerCompressScrambling INTEGER
  fclAsynCfgSerCompressMultiPacketsTimer INTEGER
  fclAsynCfgSerX29Reselection INTEGER
  fclAsynCfgSerCallReturnTransmission INTEGER
  fclAsynCfgSerDBitModification INTEGER
  fclAsynCfgSerReliableVc INTEGER
  fclAsynCfgSerCos INTEGER
  fclAsynCfgSerCir INTEGER
  fclAsynCfgSerMinCir INTEGER
  fclAsynCfgSerConversionAimedPoint INTEGER
  fclAsynCfgSerConversionIncomingCall INTEGER
  fclAsynCfgSerConversionOutgoingCall INTEGER
  fclAsynCfgSerConversionAddressCheck INTEGER

FclAsynAutoCallEntry  
SEQUENCE    
  fclAsynAutoLogPortId INTEGER
  fclAsynAutoStatus INTEGER
  fclAsynAutoCalledAddr OCTET STRING
  fclAsynAutoFacility INTEGER
  fclAsynAutoFacThroughputClass INTEGER
  fclAsynAutoCallUserDataAscii DisplayString
  fclAsynAutoCallUserDataHexa OCTET STRING
  fclAsynAutoMinimumRecallTimer INTEGER
  fclAsynAutoDiscardCharDuringTimer INTEGER

FclAsynAutoVdxKeyTranslationEntry  
SEQUENCE    
  fclAsynAutoTransLpId INTEGER
  fclAsynAutoTransTranscoding INTEGER
  fclAsynAutoTransProfile INTEGER
  fclAsynAutoTransAutoTermMode INTEGER
  fclAsynAutoTransCFKeyHandling INTEGER
  fclAsynAutoTransClearHangUp INTEGER

FclAsynMnemonicEntry  
SEQUENCE    
  fclAsynMneMnemonicId INTEGER
  fclAsynMneStatus INTEGER
  fclAsynMneName DisplayString
  fclAsynMneCalledAddr OCTET STRING
  fclAsynMneFacility INTEGER
  fclAsynMneFacThroughputClass INTEGER
  fclAsynMneCallUserDataAscii DisplayString
  fclAsynMneCallUserDataHexa OCTET STRING

FclAsynMneVdxKeyTranslationEntry  
SEQUENCE    
  fclAsynMneTransMnemonicId INTEGER
  fclAsynMneTransName DisplayString
  fclAsynMneTransTranscoding INTEGER
  fclAsynMneTransProfile INTEGER
  fclAsynMneTransAutoTermMode INTEGER
  fclAsynMneTransCFKeyHandling INTEGER
  fclAsynMneTransClearHangUp INTEGER

FclAsynPstnRemotePeerEntry  
SEQUENCE    
  fclAsynPstnRemX121Addr OCTET STRING
  fclAsynPstnRemStatus INTEGER
  fclAsynPstnRemPstnNumber OCTET STRING

FclAsynNetUserEntry  
SEQUENCE    
  fclAsynNetUserId INTEGER
  fclAsynNetStatus INTEGER
  fclAsynNetNui DisplayString
  fclAsynNetNua INTEGER

FclFraLogPortEntry  
SEQUENCE    
  fclFraLpLogPortId INTEGER
  fclFraLpInterfaceId INTEGER
  fclFraLpLmi INTEGER
  fclFraLpGroupingThreshold INTEGER
  fclFraLpFecnBecnThreshold INTEGER
  fclFraLpDeDiscardThreshold INTEGER
  fclFraLpAllDiscardThreshold INTEGER
  fclFraLpX25InterframeFlagCount INTEGER
  fclFraLpInactivityCheckDelay INTEGER
  fclFraLpCompression INTEGER
  fclFraLpCompressNegotiation INTEGER
  fclFraLpCompressScrambling INTEGER
  fclFraLpCompressMultiPacketsTimer INTEGER
  fclFraLpReliableVc INTEGER

FclFraLmiEntry  
SEQUENCE    
  fclFraLmiLogPortId INTEGER
  fclFraLmiDlci INTEGER
  fclFraLmiLmiStandard INTEGER
  fclFraLmiAccessibilityCondition INTEGER
  fclFraLmiN391FullStatusPollCount INTEGER
  fclFraLmiN392ErrorThreshold INTEGER
  fclFraLmiN393MonitoredEventCount INTEGER
  fclFraLmiT391LinkIntegPollTimer INTEGER
  fclFraLmiT392PollingVerifTimer INTEGER

FclFraPvcEndPointEntry  
SEQUENCE    
  fclFraPvcLogPortId INTEGER
  fclFraPvcDlci INTEGER
  fclFraPvcStatus INTEGER
  fclFraPvcCalledAddr OCTET STRING
  fclFraPvcSubscriberNumber INTEGER
  fclFraPvcCallDirection INTEGER
  fclFraPvcEncapsulation INTEGER
  fclFraPvcMinRecallTimer INTEGER
  fclFraPvcInactivityTimer INTEGER

FclHdlcLogPortEntry  
SEQUENCE    
  fclHdlcLpLogPortId INTEGER
  fclHdlcLpInterfaceId INTEGER
  fclHdlcLpCrcTransport INTEGER
  fclHdlcLpGroupingThreshold INTEGER
  fclHdlcLpAllDiscardThreshold INTEGER
  fclHdlcLpX25InterframeFlagCount INTEGER
  fclHdlcLpInactivityCheckDelay INTEGER
  fclHdlcLpCompression INTEGER
  fclHdlcLpCompressNegotiation INTEGER
  fclHdlcLpCompressScrambling INTEGER
  fclHdlcLpCompressMultiPacketsTimer INTEGER
  fclHdlcLpReliableVc INTEGER
  fclHdlcLpCos INTEGER
  fclHdlcLpCir INTEGER
  fclHdlcLpMinCir INTEGER

FclHdlcAutoCallEntry  
SEQUENCE    
  fclHdlcAutoLogPortId INTEGER
  fclHdlcAutoCalledAddr OCTET STRING
  fclHdlcAutoSubscriberNumber INTEGER
  fclHdlcAutoCallDirection INTEGER
  fclHdlcAutoEncapsulation INTEGER
  fclHdlcAutoMinRecallTimer INTEGER
  fclHdlcAutoInactivityTimer INTEGER

FclSdlcLogPortEntry  
SEQUENCE    
  fclSdlcLpLogPortId INTEGER
  fclSdlcLpInterfaceId INTEGER
  fclSdlcLpPhysicalUnitType INTEGER
  fclSdlcLpSubscriberNumber OCTET STRING
  fclSdlcLpBitEncoding INTEGER
  fclSdlcLpUnknownPackets INTEGER
  fclSdlcLpLogicalLinkProtocol INTEGER
  fclSdlcLpPacketSize INTEGER
  fclSdlcLpWindowSize INTEGER
  fclSdlcLpCompression INTEGER
  fclSdlcLpCompressNegotiation INTEGER
  fclSdlcLpCompressScrambling INTEGER
  fclSdlcLpCompressMultiPacketsTimer INTEGER
  fclSdlcLpReliableVc INTEGER
  fclSdlcLpCos INTEGER
  fclSdlcLpCir INTEGER
  fclSdlcLpMinCir INTEGER
  fclSdlcLpBe INTEGER

FclSdlcPriLogPortEntry  
SEQUENCE    
  fclSdlcPriLpLogPortId INTEGER
  fclSdlcPriLpLinkType INTEGER
  fclSdlcPriLpRemPuIdentification INTEGER
  fclSdlcPriLpPollingGroupResponse INTEGER
  fclSdlcPriLpPollingGroupAddress OCTET STRING

FclSdlcPriClusterEntry  
SEQUENCE    
  fclSdlcPriClusterLogPortId INTEGER
  fclSdlcPriClusterAddress OCTET STRING
  fclSdlcPriClusterStatus INTEGER
  fclSdlcPriClusterRemPu2CalledAddr OCTET STRING

FclSdlcSecLogPortEntry  
SEQUENCE    
  fclSdlcSecLpLogPortId INTEGER
  fclSdlcSecLpLinkType INTEGER
  fclSdlcSecLpRemPuIdentification INTEGER
  fclSdlcSecLpT1AcknowledgeTimer INTEGER
  fclSdlcSecLpN2RetryCount INTEGER
  fclSdlcSecLpCallRetryCount INTEGER
  fclSdlcSecLpPollingTimer INTEGER
  fclSdlcSecLpPollingMaxCount INTEGER

FclSdlcSecClusterEntry  
SEQUENCE    
  fclSdlcSecClusterLogPortId INTEGER
  fclSdlcSecClusterAddress OCTET STRING
  fclSdlcSecClusterStatus INTEGER
  fclSdlcSecClusterCalledAddr OCTET STRING
  fclSdlcSecClusterFacility INTEGER
  fclSdlcSecClusterFacThroughputClass INTEGER
  fclSdlcSecClusterMinRecallTimer INTEGER
  fclSdlcSecClusterRemPvcLogChannel INTEGER
  fclSdlcSecClusterXidStringResponse OCTET STRING
  fclSdlcSecClusterCos INTEGER
  fclSdlcSecClusterCir INTEGER
  fclSdlcSecClusterCirmin INTEGER
  fclSdlcSecClusterBc INTEGER
  fclSdlcSecClusterBe INTEGER

FclVipLogPortEntry  
SEQUENCE    
  fclVipLpLogPortId INTEGER
  fclVipLpInterfaceId INTEGER
  fclVipLpEmulationType INTEGER
  fclVipLpResponseSurveyPollingTimer INTEGER
  fclVipLpScreenRetryTimer INTEGER
  fclVipLpPrinterRetryTimer INTEGER
  fclVipLpMessageRetryNumber INTEGER
  fclVipLpPrinterMessagesManagement INTEGER

FclVipHosLogPortEntry  
SEQUENCE    
  fclVipHosLpLogPortId INTEGER
  fclVipHosLpWaitTimeOutForPrinter INTEGER
  fclVipHosLpRepAEot INTEGER
  fclVipHosLpFtbcc INTEGER

FclVipHosElementEntry  
SEQUENCE    
  fclVipHosElementId INTEGER
  fclVipHosElemStatus INTEGER
  fclVipHosElemLogPortId INTEGER
  fclVipHosElemType INTEGER
  fclVipHosElemAddress INTEGER

FclVipHosStationEntry  
SEQUENCE    
  fclVipHosStatElementId INTEGER
  fclVipHosStatStationAddress INTEGER
  fclVipHosStatStatus INTEGER

FclVipCluLogPortEntry  
SEQUENCE    
  fclVipCluLpLogPortId INTEGER
  fclVipCluLpPollingTimer INTEGER
  fclVipCluLpFailedPollingMaxNumber INTEGER
  fclVipCluLpPollingTypeAfterSelect INTEGER
  fclVipCluLpScreenKeepTimer INTEGER

FclVipCluElementEntry  
SEQUENCE    
  fclVipCluElementId INTEGER
  fclVipCluElemStatus INTEGER
  fclVipCluElemLogPortId INTEGER
  fclVipCluElemType INTEGER
  fclVipCluElemAddress INTEGER
  fclVipCluElemCalledAddr OCTET STRING
  fclVipCluElemMinRecallTimer INTEGER

FclVipCluStationEntry  
SEQUENCE    
  fclVipCluStatElementId INTEGER
  fclVipCluStatStationAddress INTEGER
  fclVipCluStatStatus INTEGER

FclB3270LogPortEntry  
SEQUENCE    
  fclB3270LpLogPortId INTEGER
  fclB3270LpInterfaceId INTEGER
  fclB3270LpEmulationType INTEGER
  fclB3270LpCodingParityType INTEGER
  fclB3270LpNoAnswerWatchDog INTEGER
  fclB3270LpMessageRetryNumber INTEGER

FclB3270HosLogPortEntry  
SEQUENCE    
  fclB3270HosLpLogPortId INTEGER
  fclB3270HosLpLineWatchDog INTEGER
  fclB3270HosLpWackTransmission INTEGER
  fclB3270HosLpAnswerToPolling INTEGER

FclB3270HosClusterEntry  
SEQUENCE    
  fclB3270HosClusterLogPortId INTEGER
  fclB3270HosClusterCluAdd INTEGER
  fclB3270HosClusterStaAdd INTEGER
  fclB3270HosClusterStatus INTEGER

FclB3270CluLogPortEntry  
SEQUENCE    
  fclB3270CluLpLogPortId INTEGER
  fclB3270CluLpPollingTimer INTEGER
  fclB3270CluLpMaxNumberOfUnwPolls INTEGER
  fclB3270CluLpReconnectionType INTEGER

FclB3270CluClusterEntry  
SEQUENCE    
  fclB3270CluClusterLogPortId INTEGER
  fclB3270CluClusterCluAdd INTEGER
  fclB3270CluClusterStaAdd INTEGER
  fclB3270CluClusterStatus INTEGER

FclB3270CluCallEntry  
SEQUENCE    
  fclB3270CluCallLogPortId INTEGER
  fclB3270CluCallCluAdd INTEGER
  fclB3270CluCallStatus INTEGER
  fclB3270CluCallCallAddr OCTET STRING
  fclB3270CluCallMinRecallTimer INTEGER

FclBX780LogPortEntry  
SEQUENCE    
  fclBX780LpLogPortId INTEGER
  fclBX780LpInterfaceId INTEGER
  fclBX780LpProtocolType INTEGER
  fclBX780LpCallDirection INTEGER
  fclBX780LpDeconnectTimer INTEGER
  fclBX780LpSurveyTimer INTEGER
  fclBX780LpCodingParityType INTEGER
  fclBX780LpEquipementType INTEGER
  fclBX780LpENQRetransTimer INTEGER
  fclBX780LpAuthorAnswerTimer INTEGER
  fclBX780LpNoAnswerWatchDog INTEGER
  fclBX780LpMessageRetryNumber INTEGER

FclBX780ConnectionEntry  
SEQUENCE    
  fclBX780ConnLogPortId INTEGER
  fclBX780ConnCalledAddr OCTET STRING
  fclBX780ConnMinimumRecallTimer INTEGER

FclBX780IdentEntry  
SEQUENCE    
  fclBX780IdentLogPortId INTEGER
  fclBX780IdentTermId OCTET STRING
  fclBX780IdentStatus INTEGER

FclBSctLogPortEntry  
SEQUENCE    
  fclBSctLpLogPortId INTEGER
  fclBSctLpInterfaceId INTEGER
  fclBSctLpLinkType INTEGER
  fclBSctLpNumberOfSYN INTEGER
  fclBSctLpSignalEnvelope INTEGER
  fclBSctLpCodingParityType INTEGER
  fclBSctLpMaxFrameNumberIn INTEGER
  fclBSctLpUnderrunManagement INTEGER
  fclBSctLpOnePadSuppressed INTEGER

FclBSctConnectionEntry  
SEQUENCE    
  fclBSctConnLogPortId INTEGER
  fclBSctConnCalledAddr OCTET STRING
  fclBSctConnCallDirection INTEGER
  fclBSctConnSubscriberNumber INTEGER
  fclBSctConnMinimumRecallTimer INTEGER

FclBSctProtocolDefinition1Entry  
SEQUENCE    
  fclBSctProtDef1LogPortId INTEGER
  fclBSctProtDef1PermanentDelimiter1 INTEGER
  fclBSctProtDef1PermanentDelimiter2 INTEGER
  fclBSctProtDef1PermanentDelimiter3 INTEGER
  fclBSctProtDef1PermanentDelimiter4 INTEGER
  fclBSctProtDef1PermanentDelimiter5 INTEGER
  fclBSctProtDef1StartFrameDelimiter1 INTEGER
  fclBSctProtDef1StartFrameDelimiter2 INTEGER
  fclBSctProtDef1StartFrameDelimiter3 INTEGER
  fclBSctProtDef1NbCharInhibited INTEGER
  fclBSctProtDef1StFrDelimiterInhib1 INTEGER
  fclBSctProtDef1StFrDelimiterInhib2 INTEGER

FclBSctProtocolDefinition2Entry  
SEQUENCE    
  fclBSctProtDef2LogPortId INTEGER
  fclBSctProtDef2DataFrameTerminator1 INTEGER
  fclBSctProtDef2DataFrameTerminator2 INTEGER
  fclBSctProtDef2DataFrameTerminator3 INTEGER
  fclBSctProtDef2ControlFrameTerminator1 INTEGER
  fclBSctProtDef2ControlFrameTerminator2 INTEGER
  fclBSctProtDef2ACK0 INTEGER
  fclBSctProtDef2ACK1 INTEGER
  fclBSctProtDef2WACK INTEGER
  fclBSctProtDef2RVI INTEGER
  fclBSctProtDef2WABT INTEGER

FclX25SlpAccessEntry  
SEQUENCE    
  fclX25AccLogPortId INTEGER
  fclX25AccInterfaceId INTEGER
  fclX25AccConnectionType INTEGER
  fclX25AccSubscriberNumber OCTET STRING
  fclX25AccPdnLinkAddress OCTET STRING
  fclX25AccX25AccessConfigId INTEGER
  fclX25AccIsdnBackupEnabling INTEGER
  fclX25AccPstnBackupEnabling INTEGER

FclX25AccPrivateNetEntry  
SEQUENCE    
  fclX25AccPrivLogPortId INTEGER
  fclX25AccPrivX25FieldsSave INTEGER
  fclX25AccPrivX25FieldsChanges OCTET STRING

FclX25AccPermanentVcEntry  
SEQUENCE    
  fclX25AccPvcLogPortId INTEGER
  fclX25AccPvcLocalLogChannel INTEGER
  fclX25AccPvcStatus INTEGER
  fclX25AccPvcCalledAddr OCTET STRING
  fclX25AccPvcRemoteLogChannel INTEGER
  fclX25AccPvcMinimumRecallTimer INTEGER
  fclX25AccPvcCallDirection INTEGER
  fclX25AccPvcFacility INTEGER
  fclX25AccPvcFacThroughputClass INTEGER

FclX25AccSwitchOverEntry  
SEQUENCE    
  fclX25AccSwLogPortId INTEGER
  fclX25AccSwMeasureCount INTEGER
  fclX25AccSwSwitchThreshold INTEGER
  fclX25AccSwSwitchBackThreshold INTEGER

FclX25AccIsdnBackupEntry  
SEQUENCE    
  fclX25AccIsdnBackLogPortId INTEGER
  fclX25AccIsdnBackIsdnInterfaceId INTEGER
  fclX25AccIsdnBackStatus INTEGER

FclX25AccIsdnRemotePeerEntry  
SEQUENCE    
  fclX25AccIsdnRemLogPortId INTEGER
  fclX25AccIsdnRemIsdnInterfaceId INTEGER
  fclX25AccIsdnRemStatus INTEGER
  fclX25AccIsdnRemX25AccessConfigId INTEGER
  fclX25AccIsdnRemPriority INTEGER
  fclX25AccIsdnRemCallRetryCount INTEGER

FclX25AccPstnBackupEntry  
SEQUENCE    
  fclX25AccPstnBackLogPortId INTEGER
  fclX25AccPstnBackStatus INTEGER
  fclX25AccPstnBackInterfaceId INTEGER
  fclX25AccPstnBackPstnNumber OCTET STRING
  fclX25AccPstnBackX25AccessConfigId INTEGER

FclX25InDIsdnEntry  
SEQUENCE    
  fclX25InDLogPortId INTEGER
  fclX25InDIsdnInterfaceId INTEGER
  fclX25InDTei INTEGER
  fclX25InDBackupEnabling INTEGER
  fclX25InDConnectionType INTEGER
  fclX25InDSubscriberNumber OCTET STRING
  fclX25InDPdnLinkAddress OCTET STRING
  fclX25InDX25AccessConfigId INTEGER
  fclX25InDInactivityTimer INTEGER
  fclX25InDActiveLinkAtBootTime INTEGER

FclX25InDSwitchOverEntry  
SEQUENCE    
  fclX25InDSwLogPortId INTEGER
  fclX25InDSwMeasureCount INTEGER
  fclX25InDSwSwitchThreshold INTEGER
  fclX25InDSwSwitchBackThreshold INTEGER

FclX25InDIsdnBackupEntry  
SEQUENCE    
  fclX25InDIsdnBackLogPortId INTEGER
  fclX25InDIsdnBackIsdnInterfaceId INTEGER
  fclX25InDIsdnBackStatus INTEGER

FclX25InDIsdnRemotePeerEntry  
SEQUENCE    
  fclX25InDIsdnRemLogPortId INTEGER
  fclX25InDIsdnRemIsdnInterfaceId INTEGER
  fclX25InDIsdnRemStatus INTEGER
  fclX25InDIsdnRemConnectionType INTEGER
  fclX25InDIsdnRemSubscriberNumber OCTET STRING
  fclX25InDIsdnRemPdnLinkAddress OCTET STRING
  fclX25InDIsdnRemX25AccConfigId INTEGER
  fclX25InDIsdnRemPriority INTEGER
  fclX25InDIsdnRemCallRetryCount INTEGER

FclX25InBIsdnEntry  
SEQUENCE    
  fclX25InBLogPortId INTEGER
  fclX25InBIsdnInterfaceId INTEGER

FclX25InBRemotePeerEntry  
SEQUENCE    
  fclX25InBRemX121Addr OCTET STRING
  fclX25InBRemPeerId INTEGER
  fclX25InBRemStatus INTEGER
  fclX25InBRemConnectionType INTEGER
  fclX25InBRemSubscriberNumber OCTET STRING
  fclX25InBRemPdnLinkAddress OCTET STRING
  fclX25InBRemX25ConfigId INTEGER
  fclX25InBRemPriority INTEGER
  fclX25InBRemCallRetryCount INTEGER
  fclX25InBRemLinkCheckPeriod INTEGER
  fclX25InBRemCheckPeriodCount INTEGER

FclX25InPstnEntry  
SEQUENCE    
  fclX25PstnLogPortId INTEGER
  fclX25PstnInterfaceId INTEGER
  fclX25PstnX25InterNodeConfigId INTEGER

FclX25PstnRemotePeerEntry  
SEQUENCE    
  fclX25PstnRemX121Addr OCTET STRING
  fclX25PstnRemStatus INTEGER
  fclX25PstnRemPstnNumber OCTET STRING

FclX25SlpInterNodeEntry  
SEQUENCE    
  fclX25SlpLogPortId INTEGER
  fclX25SlpInterfaceId INTEGER
  fclX25SlpIsdnBackupEnabling INTEGER
  fclX25SlpPstnBackupEnabling INTEGER
  fclX25SlpX25InterNodeConfigId INTEGER
  fclX25SlpDARApplicable INTEGER
  fclX25SlpBackupTimer INTEGER

FclX25SlpSwitchOverEntry  
SEQUENCE    
  fclX25SlpSwLogPortId INTEGER
  fclX25SlpSwMeasureCount INTEGER
  fclX25SlpSwSwitchThreshold INTEGER
  fclX25SlpSwSwitchBackThreshold INTEGER

FclX25SlpIsdnBackupEntry  
SEQUENCE    
  fclX25SlpIsdnBackLogPortId INTEGER
  fclX25SlpIsdnBackIsdnInterfaceId INTEGER
  fclX25SlpIsdnBackStatus INTEGER

FclX25SlpIsdnRemotePeerEntry  
SEQUENCE    
  fclX25SlpIsdnRemLogPortId INTEGER
  fclX25SlpIsdnRemIsdnInterfaceId INTEGER
  fclX25SlpIsdnRemStatus INTEGER
  fclX25SlpIsdnRemX25InterNodeConfigId INTEGER
  fclX25SlpIsdnRemPriority INTEGER
  fclX25SlpIsdnRemCallRetryCount INTEGER

FclX25SlpPstnBackupEntry  
SEQUENCE    
  fclX25SlpPstnBackLogPortId INTEGER
  fclX25SlpPstnBackStatus INTEGER
  fclX25SlpPstnBackInterfaceId INTEGER
  fclX25SlpPstnBackPstnNumber OCTET STRING
  fclX25SlpPstnBackX25InterNodeConfigId INTEGER

FclX25MlpEntry  
SEQUENCE    
  fclX25MlpLogPortId INTEGER
  fclX25MlpLink1InterfaceId INTEGER
  fclX25MlpLink2InterfaceId INTEGER
  fclX25MlpLink3InterfaceId INTEGER
  fclX25MlpLink4InterfaceId INTEGER
  fclX25MlpIsdnOverflow INTEGER
  fclX25MlpPstnOverflow INTEGER
  fclX25MlpX25InterNodeConfigId INTEGER
  fclX25MlpDARApplicable INTEGER

FclX25MlpParameterEntry  
SEQUENCE    
  fclX25MlpParamLogPortId INTEGER
  fclX25MlpMwMultilinkWindowSize INTEGER
  fclX25MlpRxMlpMxWinGuardRegion INTEGER
  fclX25MlpMt1LostFrameTimer INTEGER
  fclX25MlpMt3ResetConfirmationTimer INTEGER
  fclX25MlpMt4DownLinkDetectionTimer INTEGER
  fclX25MlpFramesMaxCountByLink INTEGER
  fclX25MlpRestartTxAfterResetRx INTEGER
  fclX25MlpTns3Level3CheckTimer INTEGER

FclX25MlpOverflowEntry  
SEQUENCE    
  fclX25MlpOvLogPortId INTEGER
  fclX25MlpOvMeasureCount INTEGER
  fclX25MlpOvOverflowThreshold INTEGER
  fclX25MlpOvOverflowBackThreshold INTEGER

FclX25MlpIsdnOverflowEntry  
SEQUENCE    
  fclX25MlpIsdnOverLogPortId INTEGER
  fclX25MlpIsdnOverIsdnInterfaceId INTEGER
  fclX25MlpIsdnOverStatus INTEGER
  fclX25MlpIsdnOverBChannelCount INTEGER

FclX25MlpIsdnRemotePeerEntry  
SEQUENCE    
  fclX25MlpIsdnRemLogPortId INTEGER
  fclX25MlpIsdnRemPeerId INTEGER
  fclX25MlpIsdnRemStatus INTEGER
  fclX25MlpIsdnRemPriority INTEGER
  fclX25MlpIsdnRemCallRetryCount INTEGER

FclX25MlpPstnOverflowEntry  
SEQUENCE    
  fclX25MlpPstnOvLogPortId INTEGER
  fclX25MlpPstnOvStatus INTEGER
  fclX25MlpPstnOvInterfaceId INTEGER
  fclX25MlpPstnOvPstnNumber OCTET STRING

FclPppSerialLogPortEntry  
SEQUENCE    
  fclPppSerLpLogPortId INTEGER
  fclPppSerLpInterfaceId INTEGER
  fclPppSerLpLocalSubscriberNb OCTET STRING
  fclPppSerLpConfigId INTEGER
  fclPppSerLpCos INTEGER
  fclPppSerLpCir INTEGER
  fclPppSerLpMinCir INTEGER
  fclPppSerLpBe INTEGER

FclPppSerialAutoCallEntry  
SEQUENCE    
  fclPppSerAutoLogPortId INTEGER
  fclPppSerAutoStatus INTEGER
  fclPppSerAutoRemoteAddress OCTET STRING
  fclPppSerAutoMinimumRecallTimer INTEGER
  fclPppSerAutoInactivityTimer INTEGER
  fclPppSerAutoReliableVc INTEGER
  fclPppSerAutoCompression INTEGER
  fclPppSerAutoCompressNegotiation INTEGER
  fclPppSerAutoCompressScrambling INTEGER
  fclPppSerAutoCompressMultiPktTimer INTEGER

FclPppPstnLogPortEntry  
SEQUENCE    
  fclPppPstnLpLogPortId INTEGER
  fclPppPstnLpInterfaceId INTEGER
  fclPppPstnLpLocalSubscriberNb OCTET STRING
  fclPppPstnLpConfigId INTEGER

FclPppPstnRemotePeerEntry  
SEQUENCE    
  fclPppPstnRemX121Addr OCTET STRING
  fclPppPstnRemStatus INTEGER
  fclPppPstnRemPstnNumber OCTET STRING

FclPppBIsdnLogPortEntry  
SEQUENCE    
  fclPppBIsdnLpLogPortId INTEGER
  fclPppBIsdnLpIsdnInterfaceId INTEGER

FclPppBIsdnLocalBriEntry  
SEQUENCE    
  fclPppBIsdnBriId INTEGER
  fclPppBIsdnBriStatus INTEGER
  fclPppBIsdnBriLocalSubsNb1 OCTET STRING
  fclPppBIsdnBriLocalSubsNb2 OCTET STRING

FclPppBIsdnRemotePeerEntry  
SEQUENCE    
  fclPppBIsdnRemX121Addr OCTET STRING
  fclPppBIsdnRemPeerId INTEGER
  fclPppBIsdnRemStatus INTEGER
  fclPppBIsdnRemConfigId INTEGER
  fclPppBIsdnRemPriority INTEGER
  fclPppBIsdnRemCallRetryCount INTEGER
  fclPppBIsdnRemLinkCheckPeriod INTEGER
  fclPppBIsdnRemCheckPeriodCount INTEGER

FclPppBIsdnLocalPriEntry  
SEQUENCE    
  fclPppBIsdnPriId INTEGER
  fclPppBIsdnPriStatus INTEGER
  fclPppBIsdnPriLocalSubs DisplayString

FclPppConfigurationsEntry  
SEQUENCE    
  fclPppCfgConfigId INTEGER
  fclPppCfgStatus INTEGER
  fclPppCfgDescription DisplayString
  fclPppCfgLcpMagicNumber INTEGER
  fclPppCfgLcpLocalMru INTEGER
  fclPppCfgLcpLocalMtu INTEGER
  fclPppCfgNcpBridge INTEGER
  fclPppCfgNcpIp INTEGER
  fclPppCfgNcpIpx INTEGER
  fclPppCfgNcpClnp INTEGER
  fclPppCfgAuthentication INTEGER
  fclPppCfgAuthenticationMode INTEGER
  fclPppCfgIpAddrAssignment INTEGER

FclPppConfigTimersEntry  
SEQUENCE    
  fclPppCftConfigId INTEGER
  fclPppCftLcpEchoRequestPeriod INTEGER
  fclPppCftConnectionTimer INTEGER
  fclPppCftRestartTimer INTEGER
  fclPppCftConfigureMaxCount INTEGER
  fclPppCftTerminateMaxCount INTEGER
  fclPppCftFailureMaxCount INTEGER

FclPppCfaRemotePeerEntry  
SEQUENCE    
  fclPppCfaRemPeerId INTEGER
  fclPppCfaRemStatus INTEGER
  fclPppCfaRemIdentifier DisplayString
  fclPppCfaRemPassword DisplayString

FclFrCeLogPortEntry  
SEQUENCE    
  fclFrCeLpLogPortId INTEGER
  fclFrCeLpInterfaceId INTEGER
  fclFrCeLpLocalAddress OCTET STRING
  fclFrCeLpConfigId INTEGER
  fclFrCeLpLmi INTEGER

FclFrCeParGenEntry  
SEQUENCE    
  fclFrCeParGenLogPortId INTEGER
  fclFrCeParGenDlcSetupAlarmThreshold INTEGER
  fclFrCeParGenDlcSetupDiscardThreshold INTEGER
  fclFrCeParGenBookingUbrThreshold INTEGER
  fclFrCeParGenBookingVbrRtThreshold INTEGER
  fclFrCeParGenVoiceMaxTransitDelay INTEGER

FclFrTeLogPortEntry  
SEQUENCE    
  fclFrTeLpLogPortId INTEGER
  fclFrTeLpInterfaceId INTEGER
  fclFrTeLpLocalAddress OCTET STRING
  fclFrTeLpConfigId INTEGER
  fclFrTeLpLmi INTEGER
  fclFrTeLpFragmentation INTEGER
  fclFrTeLpLinkLayerConsolidation INTEGER
  fclFrTeLpLogPortBackupEnabling INTEGER
  fclFrTeLpFragFrameSize INTEGER
  fclFrTeLpBackupTimer INTEGER

FclFrTeParGenEntry  
SEQUENCE    
  fclFrTeParGenLogPortId INTEGER
  fclFrTeParGenDlcSetupAlarmThreshold INTEGER
  fclFrTeParGenDlcSetupDiscardThreshold INTEGER
  fclFrTeParGenBookingUbrThreshold INTEGER
  fclFrTeParGenBookingVbrRtThreshold INTEGER
  fclFrTeParGenVoiceMaxTransitDelay INTEGER
  fclFrTeParGenDynamicEir INTEGER
  fclFrTeParGenPredictionRoundTripDelay INTEGER
  fclFrTeParGenNetworkBandwidth INTEGER

FclFrTeIsdnBackupEntry  
SEQUENCE    
  fclFrTeIsdnBackLogPortId INTEGER
  fclFrTeIsdnBackIsdnInterfaceId INTEGER
  fclFrTeIsdnBackStatus INTEGER

FclFrTeIsdnRemotePeerEntry  
SEQUENCE    
  fclFrTeIsdnRemLogPortId INTEGER
  fclFrTeIsdnRemRemotePeerId INTEGER
  fclFrTeIsdnRemStatus INTEGER
  fclFrTeIsdnRemPriority INTEGER
  fclFrTeIsdnRemCallRetryCount INTEGER
  fclFrTeIsdnRemProtocol INTEGER
  fclFrTeIsdnRemConfigId INTEGER

FclFrSeLogPortEntry  
SEQUENCE    
  fclFrSeLpLogPortId INTEGER
  fclFrSeLpInterfaceId INTEGER
  fclFrSeLpConfigId INTEGER
  fclFrSeLpLogPortBackupEnabling INTEGER
  fclFrSeLpBackupTimer INTEGER

FclFrSeIsdnBackupEntry  
SEQUENCE    
  fclFrSeIsdnBackLogPortId INTEGER
  fclFrSeIsdnBackIsdnInterfaceId INTEGER
  fclFrSeIsdnBackStatus INTEGER

FclFrSeIsdnRemotePeerEntry  
SEQUENCE    
  fclFrSeIsdnRemLogPortId INTEGER
  fclFrSeIsdnRemRemotePeerId INTEGER
  fclFrSeIsdnRemStatus INTEGER
  fclFrSeIsdnRemConfigId INTEGER
  fclFrSeIsdnRemPriority INTEGER
  fclFrSeIsdnRemCallRetryCount INTEGER

FclFrSeInBIsdnLogPortEntry  
SEQUENCE    
  fclFrSeInBLpLogPortId INTEGER
  fclFrSeInBLpIsdnInterfaceId INTEGER

FclFrSeInBRemotePeerEntry  
SEQUENCE    
  fclFrSeInBRemRemoteAddress OCTET STRING
  fclFrSeInBRemPeerId INTEGER
  fclFrSeInBRemStatus INTEGER
  fclFrSeInBRemPriority INTEGER
  fclFrSeInBRemCallRetryCount INTEGER
  fclFrSeInBRemConfigId INTEGER

FclFrPvcEndPointEntry  
SEQUENCE    
  fclFrPvcLinkType INTEGER
  fclFrPvcLinkId INTEGER
  fclFrPvcDlci INTEGER
  fclFrPvcStatus INTEGER
  fclFrPvcCalledAddress OCTET STRING
  fclFrPvcCallDirection INTEGER
  fclFrPvcEncapsulation INTEGER
  fclFrPvcBackupEnabling INTEGER
  fclFrPvcBackupDlci INTEGER
  fclFrPvcTrafficManagementStrategy INTEGER
  fclFrPvcNetworkTransport INTEGER

FclFrPvcQualityOfServiceEntry  
SEQUENCE    
  fclFrPvcQosLinkType INTEGER
  fclFrPvcQosLinkId INTEGER
  fclFrPvcQosDlci INTEGER
  fclFrPvcQosCos INTEGER
  fclFrPvcQosInBc INTEGER
  fclFrPvcQosInBe INTEGER
  fclFrPvcQosInCir INTEGER
  fclFrPvcQosInMinCir INTEGER
  fclFrPvcQosOutBc INTEGER
  fclFrPvcQosOutBe INTEGER
  fclFrPvcQosOutCir INTEGER
  fclFrPvcQosOutMinCir INTEGER

FclFrPvcX25EncapsulationEntry  
SEQUENCE    
  fclFrPvcX25LinkType INTEGER
  fclFrPvcX25LinkId INTEGER
  fclFrPvcX25Dlci INTEGER
  fclFrPvcX25AssociatedAddress OCTET STRING
  fclFrPvcX25InterNodeConfigId INTEGER

FclFrPvcSnaEncapsulationEntry  
SEQUENCE    
  fclFrPvcSnaLinkType INTEGER
  fclFrPvcSnaLinkId INTEGER
  fclFrPvcSnaDlci INTEGER
  fclFrPvcSnaConnTestEnabling INTEGER
  fclFrPvcSnaLevel3Pid INTEGER
  fclFrPvcSnaDestinationSap OCTET STRING
  fclFrPvcSnaSourceSap OCTET STRING
  fclFrPvcSnaT1ReplyTimer INTEGER
  fclFrPvcSnaN2RetryCount INTEGER
  fclFrPvcSnaT2ReceiverAckTimer INTEGER
  fclFrPvcSnaN3AcknowledgedCount INTEGER
  fclFrPvcSnaNwIncrementAckCount INTEGER
  fclFrPvcSnaTwTransmitWinSize INTEGER
  fclFrPvcSnaRwReceiveWinSize INTEGER

FclFrPvcSnaBanEncapsulationEntry  
SEQUENCE    
  fclFrPvcSnaBanLinkType INTEGER
  fclFrPvcSnaBanLinkId INTEGER
  fclFrPvcSnaBanDlci INTEGER
  fclFrPvcSnaBanPuId INTEGER
  fclFrPvcSnaBanConnTestEnabling INTEGER
  fclFrPvcSnaBanLink INTEGER
  fclFrPvcSnaBanT1ReplyTimer INTEGER
  fclFrPvcSnaBanN2RetryCount INTEGER
  fclFrPvcSnaBanT2ReceiverAckTimer INTEGER
  fclFrPvcSnaBanN3AcknowledgedCount INTEGER
  fclFrPvcSnaBanNwIncrementAckCount INTEGER
  fclFrPvcSnaBanTwTransmitWinSize INTEGER
  fclFrPvcSnaBanRwReceiveWinSize INTEGER
  fclFrPvcSnaBanMinRecallTimer INTEGER

FclFrPvcTunEndPointEntry  
SEQUENCE    
  fclFrPvcTunLinkType INTEGER
  fclFrPvcTunLinkId INTEGER
  fclFrPvcTunDlci INTEGER
  fclFrPvcTunStatus INTEGER
  fclFrPvcTunInCir INTEGER
  fclFrPvcTunOutCir INTEGER
  fclFrPvcTunBackupEnabling INTEGER
  fclFrPvcTunBackupDlci INTEGER
  fclFrPvcTunAssociatedAddress OCTET STRING
  fclFrPvcTunFrseConfiguration INTEGER

FclFrBackupEntry  
SEQUENCE    
  fclFrMainLPId INTEGER
  fclFrMainDlci INTEGER
  fclFrBackupLPId INTEGER
  fclFrBackupDlci INTEGER
  fclFrBackupStatus INTEGER

FclFrConfigCeTeEntry  
SEQUENCE    
  fclFrCfcConfigId INTEGER
  fclFrCfcStatus INTEGER
  fclFrCfcDescription DisplayString
  fclFrCfcProfileId INTEGER
  fclFrCfcModificationCount INTEGER

FclFrCfcGeneralParameterEntry  
SEQUENCE    
  fclFrCfcGenConfigId INTEGER
  fclFrCfcGenMinimumRecallTimer INTEGER
  fclFrCfcGenInactivityCheckDelay INTEGER
  fclFrCfcGenInactivityTimer INTEGER
  fclFrCfcGenUnuseTimer INTEGER
  fclFrCfcGenSVC INTEGER

FclFrCfcSignallingParameterEntry  
SEQUENCE    
  fclFrCfcSigConfigId INTEGER
  fclFrCfcSigOuputTimeout INTEGER
  fclFrCfcSigSignalOutputWinSize INTEGER
  fclFrCfcSigN200RetransMaxCount INTEGER
  fclFrCfcSigT200RetransTimer INTEGER
  fclFrCfcSigT203InactivityTimer INTEGER
  fclFrCfcSigT303SetupResponseTimer INTEGER
  fclFrCfcSigT305DisconnectResponseTimer INTEGER
  fclFrCfcSigT308ReleaseResponseTimer INTEGER
  fclFrCfcSigT310CallProceedingTimer INTEGER
  fclFrCfcSigT316RestartAcknowledgeTimer INTEGER
  fclFrCfcSigConversionAimedPoint INTEGER

FclFrCfcEiCodingEntry  
SEQUENCE    
  fclFrCfcEiCodConfigId INTEGER
  fclFrCfcEiCodCalledTypNum INTEGER
  fclFrCfcEiCodCalledNumPlanId INTEGER
  fclFrCfcEiCodCallingTypNum INTEGER
  fclFrCfcEiCodCallingNumPlanId INTEGER

FclFrCfcLmiParameterEntry  
SEQUENCE    
  fclFrCfcLmiConfigId INTEGER
  fclFrCfcLmiDlci INTEGER
  fclFrCfcLmiStandard INTEGER
  fclFrCfcLmiAccessibilityCondition INTEGER
  fclFrCfcLmiN391FullStatusPollCount INTEGER
  fclFrCfcLmiN392ErrorThreshold INTEGER
  fclFrCfcLmiN393MonitoredEventCount INTEGER
  fclFrCfcLmiT391LinkIntegPollTimer INTEGER
  fclFrCfcLmiT392PollingVerifTimer INTEGER
  fclFrCfcLmiAsynchronousStatusReport INTEGER

FclFrConfigSeEntry  
SEQUENCE    
  fclFrCfsConfigId INTEGER
  fclFrCfsStatus INTEGER
  fclFrCfsDescription DisplayString
  fclFrCfsProfileId INTEGER
  fclFrCfsModificationCount INTEGER

FclFrCfsGeneralParameterEntry  
SEQUENCE    
  fclFrCfsGenConfigId INTEGER
  fclFrCfsGenCallReturnTransmission INTEGER
  fclFrCfsGenUnuseTimer INTEGER
  fclFrCfsGenDlcSetupAlarmThreshold INTEGER
  fclFrCfsGenDlcSetupDiscardThreshold INTEGER
  fclFrCfsGenBookingUbrThreshold INTEGER
  fclFrCfsGenBookingVbrRtThreshold INTEGER
  fclFrCfsGenBehavior INTEGER
  fclFrCfsGenDynamicEir INTEGER
  fclFrCfsGenPredictionRoundTripDelay INTEGER
  fclFrCfsGenNetworkBandwidth INTEGER

FclFrCfsSignallingEntry  
SEQUENCE    
  fclFrCfsSigConfigId INTEGER
  fclFrCfsSigOuputTimeout INTEGER
  fclFrCfsSigSignalOutputWinSize INTEGER
  fclFrCfsSigN200RetransMaxCount INTEGER
  fclFrCfsSigT200RetransTimer INTEGER
  fclFrCfsSigT203InactivityTimer INTEGER
  fclFrCfsSigT303SetupResponseTimer INTEGER
  fclFrCfsSigT305DisconnectResponseTimer INTEGER
  fclFrCfsSigT308ReleaseResponseTimer INTEGER
  fclFrCfsSigT310CallProceedingTimer INTEGER
  fclFrCfsSigT316RestartAcknowledgeTimer INTEGER

FclInterUnitLinkEntry  
SEQUENCE    
  fclIulLogPortId INTEGER
  fclIulInterfaceId INTEGER
  fclIulCallReturnTransmission INTEGER
  fclIulConversionAimedPoint INTEGER
  fclIulConversionIncomingCall INTEGER
  fclIulConversionOutgoingCall INTEGER
  fclIulConversionAddressCheck INTEGER

FclX25ConfigAccessEntry  
SEQUENCE    
  fclX25CfaConfigId INTEGER
  fclX25CfaStatus INTEGER
  fclX25CfaDescription DisplayString
  fclX25CfaProfileId INTEGER
  fclX25CfaModificationCount INTEGER

FclX25CfaDataLinkNetworkEntry  
SEQUENCE    
  fclX25CfaDlnConfigId INTEGER
  fclX25CfaDlnStationType INTEGER
  fclX25CfaDlnNetworkType INTEGER
  fclX25CfaDlnN2RetryCount INTEGER
  fclX25CfaDlnT1AcknowledgeTimer INTEGER
  fclX25CfaDlnT2AcknwledgeDelayTimer INTEGER
  fclX25CfaDlnKWindowSize INTEGER
  fclX25CfaDlnEachPacketAcknowledgement INTEGER
  fclX25CfaDlnLowestIncomingChannel INTEGER
  fclX25CfaDlnIncomingChannelCount INTEGER
  fclX25CfaDlnLowestTwoWayChannel INTEGER
  fclX25CfaDlnTwoWayChannelCount INTEGER
  fclX25CfaDlnLowestOutgoingChannel INTEGER
  fclX25CfaDlnOutgoingChannelCount INTEGER
  fclX25CfaDlnOutgoingChannelNumbering INTEGER
  fclX25CfaDlnDBitModification INTEGER

FclX25CfaFacilityEntry  
SEQUENCE    
  fclX25CfaFacConfigId INTEGER
  fclX25CfaFacClosedUserGroup INTEGER
  fclX25CfaFacReverseCharging INTEGER
  fclX25CfaFacTransitDelay INTEGER
  fclX25CfaFacOutputMarkers INTEGER
  fclX25CfaFacInputMarkers INTEGER
  fclX25CfaFacOutputUnknownFacility INTEGER
  fclX25CfaFacInputUnknownFacility INTEGER

FclX25CfaNegotiatedFacilityEntry  
SEQUENCE    
  fclX25CfaNegConfigId INTEGER
  fclX25CfaNegOutputFastSelect INTEGER
  fclX25CfaNegInputFastSelect INTEGER
  fclX25CfaNegThroughputClass INTEGER
  fclX25CfaNegDefOutThroughputClass INTEGER
  fclX25CfaNegDefInThroughputClass INTEGER
  fclX25CfaNegMaxOutThroughputClass INTEGER
  fclX25CfaNegMaxInThroughputClass INTEGER
  fclX25CfaNegPacketSize INTEGER
  fclX25CfaNegDefOutPacketSize INTEGER
  fclX25CfaNegDefInPacketSize INTEGER
  fclX25CfaNegMaxOutPacketSize INTEGER
  fclX25CfaNegMaxInPacketSize INTEGER
  fclX25CfaNegMinOutPacketSize INTEGER
  fclX25CfaNegMinInPacketSize INTEGER
  fclX25CfaNegWindowSize INTEGER
  fclX25CfaNegDefOutWindowSize INTEGER
  fclX25CfaNegDefInWindowSize INTEGER
  fclX25CfaNegMaxOutWindowSize INTEGER
  fclX25CfaNegMaxInWindowSize INTEGER

FclX25CfaSignallingEntry  
SEQUENCE    
  fclX25CfaSigConfigId INTEGER
  fclX25CfaSigType INTEGER
  fclX25CfaSigPacketAddressCount INTEGER
  fclX25CfaSigSubAddressTransmission INTEGER
  fclX25CfaSigPdnIndicator INTEGER
  fclX25CfaSigConversionAimedPoint INTEGER
  fclX25CfaSigConversionIncomingCall INTEGER
  fclX25CfaSigConversionOutgoingCall INTEGER
  fclX25CfaSigConversionAddressCheck INTEGER
  fclX25CfaSigConvMultiCalledAddrInCall INTEGER
  fclX25CfaSigConvMultiCallingAddrInCall INTEGER
  fclX25CfaSigConvMultiCalledAddrOutCall INTEGER
  fclX25CfaSigConvMultiCallingAddrOutCall INTEGER
  fclX25CfaSigOutPacketCauseField INTEGER
  fclX25CfaSigInPacketCauseField INTEGER
  fclX25CfaSigT11CallResponseTimer INTEGER
  fclX25CfaSigCallAcceptedFormat INTEGER
  fclX25CfaSigClearFormat INTEGER

FclX25CfaServiceEntry  
SEQUENCE    
  fclX25CfaSerConfigId INTEGER
  fclX25CfaSerReliableVc INTEGER
  fclX25CfaSerCharging INTEGER
  fclX25CfaSerX29Reselection INTEGER
  fclX25CfaSerRemoteExclusiveLink INTEGER
  fclX25CfaSerStatLoadAndTraffic INTEGER
  fclX25CfaSerStatSignalling INTEGER
  fclX25CfaSerStatTotalizer INTEGER
  fclX25CfaSerStatCompression INTEGER
  fclX25CfaSerCompression INTEGER
  fclX25CfaSerCompressNegotiation INTEGER
  fclX25CfaSerCompressScrambling INTEGER
  fclX25CfaSerCompressMultiPacketsTimer INTEGER
  fclX25CfaSerCos INTEGER
  fclX25CfaSerCir INTEGER
  fclX25CfaSerMinCir INTEGER
  fclX25CfaSerBe INTEGER

FclX25CfaPackingEntry  
SEQUENCE    
  fclX25CfaPackPrivateZoSb OCTET STRING
  fclX25CfaPackStatus INTEGER
  fclX25CfaPackSubAddress OCTET STRING

FclX25CfaClosedUserGroupEntry  
SEQUENCE    
  fclX25CfaCugLogPortId INTEGER
  fclX25CfaCugClosedUserGroupId INTEGER
  fclX25CfaCugStatus INTEGER
  fclX25CfaCugChecking INTEGER
  fclX25CfaCugClosedUserGroupExt INTEGER

FclX25ConfigInterNodeEntry  
SEQUENCE    
  fclX25CfnConfigId INTEGER
  fclX25CfnStatus INTEGER
  fclX25CfnDescription DisplayString
  fclX25CfnProfileId INTEGER
  fclX25CfnModificationCount INTEGER

FclX25CfnDataLinkNetworkEntry  
SEQUENCE    
  fclX25CfnDlnConfigId INTEGER
  fclX25CfnDlnStationType INTEGER
  fclX25CfnDlnN2RetryCount INTEGER
  fclX25CfnDlnT1AcknowledgeTimer INTEGER
  fclX25CfnDlnT2AcknowledgeDelayTimer INTEGER
  fclX25CfnDlnKWindowSize INTEGER
  fclX25CfnDlnEachPacketAcknowledgement INTEGER
  fclX25CfnDlnLowestIncomingChannel INTEGER
  fclX25CfnDlnIncomingChannelCount INTEGER
  fclX25CfnDlnLowestTwoWayChannel INTEGER
  fclX25CfnDlnTwoWayChannelCount INTEGER
  fclX25CfnDlnLowestOutgoingChannel INTEGER
  fclX25CfnDlnOutgoingChannelCount INTEGER
  fclX25CfnDlnOutgoingChannelNumbering INTEGER
  fclX25CfnDlnDBitModification INTEGER

FclX25CfnNegotiatedFacilityEntry  
SEQUENCE    
  fclX25CfnNegConfigId INTEGER
  fclX25CfnNegOutputFastSelect INTEGER
  fclX25CfnNegInputFastSelect INTEGER
  fclX25CfnNegThroughputClass INTEGER
  fclX25CfnNegDefOutThroughputClass INTEGER
  fclX25CfnNegDefInThroughputClass INTEGER
  fclX25CfnNegMaxOutThroughputClass INTEGER
  fclX25CfnNegMaxInThroughputClass INTEGER
  fclX25CfnNegPacketSize INTEGER
  fclX25CfnNegDefOutPacketSize INTEGER
  fclX25CfnNegDefInPacketSize INTEGER
  fclX25CfnNegMaxOutPacketSize INTEGER
  fclX25CfnNegMaxInPacketSize INTEGER
  fclX25CfnNegMinOutPacketSize INTEGER
  fclX25CfnNegMinInPacketSize INTEGER
  fclX25CfnNegWindowSize INTEGER
  fclX25CfnNegDefOutWindowSize INTEGER
  fclX25CfnNegDefInWindowSize INTEGER
  fclX25CfnNegMaxOutWindowSize INTEGER
  fclX25CfnNegMaxInWindowSize INTEGER

FclX25CfnSignallingEntry  
SEQUENCE    
  fclX25CfnSigConfigId INTEGER
  fclX25CfnSigSubAddressTransmission INTEGER
  fclX25CfnSigConversionAimedPoint INTEGER
  fclX25CfnSigConversionIncomingCall INTEGER
  fclX25CfnSigConversionOutgoingCall INTEGER
  fclX25CfnSigConversionAddressCheck INTEGER
  fclX25CfnSigConvMultiCalledAddrInCall INTEGER
  fclX25CfnSigConvMultiCallingAddrInCall INTEGER
  fclX25CfnSigConvMultiCalledAddrOutCall INTEGER
  fclX25CfnSigConvMultiCallingAddrOutCall INTEGER
  fclX25CfnSigT11CallResponseTimer INTEGER
  fclX25CfnSigCallAcceptedFormat INTEGER

FclX25CfnServiceEntry  
SEQUENCE    
  fclX25CfnSerConfigId INTEGER
  fclX25CfnSerReliableVc INTEGER
  fclX25CfnSerCharging INTEGER
  fclX25CfnSerX29Reselection INTEGER
  fclX25CfnSerRemoteExclusiveLink INTEGER
  fclX25CfnSerCallReturnTransmission INTEGER
  fclX25CfnSerStatLoadAndTraffic INTEGER
  fclX25CfnSerStatSignalling INTEGER
  fclX25CfnSerStatTotalizer INTEGER
  fclX25CfnSerStatCompression INTEGER

FclX25CfmTransmitFlowControlEntry  
SEQUENCE    
  fclX25CfmFlowCtrlPacketSize INTEGER
  fclX25CfmFlowCtrlMaxWindowSize INTEGER

FcwAddrConvIncomingCallEntry  
SEQUENCE    
  fcwConvInExternalAddr OCTET STRING
  fcwConvInStatus INTEGER
  fcwConvInConvertedAddr OCTET STRING
  fcwConvInOrderNum INTEGER

FcwAddrConvOutgoingCallEntry  
SEQUENCE    
  fcwConvOutExternalAddr OCTET STRING
  fcwConvOutStatus INTEGER
  fcwConvOutConvertedAddr OCTET STRING
  fcwConvOutOrderNum INTEGER

FcwAddrConvMultiCriterionInCallEntry  
SEQUENCE    
  fcwConvMultiInConvID OCTET STRING
  fcwConvMultiInExternalAddr OCTET STRING
  fcwConvMultiInStatus INTEGER
  fcwConvMultiInConvertedAddr OCTET STRING
  fcwConvMultiInOrderNum INTEGER

FcwAddrConvMultiCriterionOutCallEntry  
SEQUENCE    
  fcwConvMultiOutConvID OCTET STRING
  fcwConvMultiOutExternalAddr OCTET STRING
  fcwConvMultiOutStatus INTEGER
  fcwConvMultiOutConvertedAddr OCTET STRING
  fcwConvMultiOutOrderNum INTEGER

FcwAddrConvCondOutgoingCallEntry  
SEQUENCE    
  fcwConvCondOutExternalAddr OCTET STRING
  fcwConvCondOutTryOn INTEGER
  fcwConvCondOutStatus INTEGER
  fcwConvCondOutConvertedAddr OCTET STRING

FcwRouteEntry  
SEQUENCE    
  fcwRoutRouteId INTEGER
  fcwRoutLogPortId INTEGER
  fcwRoutChannelId INTEGER
  fcwRoutStatus INTEGER
  fcwRoutType INTEGER

FcwDnicRoutingEntry  
SEQUENCE    
  fcwDnicDataNetworkIdentifierCode OCTET STRING
  fcwDnicRouteId INTEGER
  fcwDnicStatus INTEGER

FcwZoRoutingEntry  
SEQUENCE    
  fcwZoZone OCTET STRING
  fcwZoRouteId INTEGER
  fcwZoStatus INTEGER

FcwSbRoutingEntry  
SEQUENCE    
  fcwSbSubscriberNumber OCTET STRING
  fcwSbRouteId INTEGER
  fcwSbStatus INTEGER

FcwSerClearAnalysisEntry  
SEQUENCE    
  fcwSClearAnalysId INTEGER
  fcwSClearAnalysStatus INTEGER
  fcwSClearAnalysCause DisplayString
  fcwSClearAnalysDiag DisplayString

FcwSQOSX25Entry  
SEQUENCE    
  fcwSQOSX25CalledAddress OCTET STRING
  fcwSQOSX25CallingAddress OCTET STRING
  fcwSQOSX25CUDProfileId INTEGER
  fcwSQOSX25Status INTEGER
  fcwSQOSX25PriorityLevel INTEGER
  fcwSQOSX25QOSProfileId INTEGER
  fcwSQOSX25Cos INTEGER
  fcwSQOSX25TrafficManagementStrategy INTEGER

FcwSCUDProfilesEntry  
SEQUENCE    
  fcwSCUDProfilesId INTEGER
  fcwSCUDProfilesStatus INTEGER
  fcwSCUDProfilesCUD OCTET STRING

FcwSQOSProfilesEntry  
SEQUENCE    
  fcwSQOSProfilesId INTEGER
  fcwSQOSProfilesStatus INTEGER
  fcwSQOSProfilesCIR INTEGER
  fcwSQOSProfilesCIRmin INTEGER
  fcwSQOSProfilesBc INTEGER
  fcwSQOSProfilesBe INTEGER

FcvVirtualPortEntry  
SEQUENCE    
  fcvVpVirtualPortId INTEGER
  fcvVpStatus INTEGER
  fcvVpType INTEGER
  fcvVpModuleId INTEGER

FcvLocalVirtualPortEntry  
SEQUENCE    
  fcvLvpVirtualPortId INTEGER
  fcvLvpLogicalPortId INTEGER

FcvLvpFltConditionEntry  
SEQUENCE    
  fcvLvpFltCondConditionId INTEGER
  fcvLvpFltCondStatus INTEGER
  fcvLvpFltCondOffset INTEGER
  fcvLvpFltCondMask OCTET STRING
  fcvLvpFltCondValue OCTET STRING

FcvLvpFltFilterEntry  
SEQUENCE    
  fcvLvpFltFilterId INTEGER
  fcvLvpFltFilterStatus INTEGER
  fcvLvpFltFilterCondition1Id INTEGER
  fcvLvpFltFilterCondition2Id INTEGER
  fcvLvpFltFilterCondition3Id INTEGER

FcvLvpFltFilteringEntry  
SEQUENCE    
  fcvLvpFltFilteringVirtualPortId INTEGER
  fcvLvpFltFilteringFilterId INTEGER
  fcvLvpFltFilteringStatus INTEGER
  fcvLvpFltFilteringType INTEGER

FcvRvpConnectionEntry  
SEQUENCE    
  fcvRvpConnRemoteAddress OCTET STRING
  fcvRvpConnEncapsulation INTEGER
  fcvRvpConnConnectionId INTEGER
  fcvRvpConnStatus INTEGER
  fcvRvpConnFlowTypeMask INTEGER
  fcvRvpConnModule0VpId INTEGER
  fcvRvpConnModule1VpId INTEGER
  fcvRvpConnModule2VpId INTEGER
  fcvRvpConnCallDirection INTEGER
  fcvRvpConnGrouping INTEGER
  fcvRvpConnMinimumRecallTimer INTEGER
  fcvRvpConnInactivityTimer INTEGER
  fcvRvpConnCir INTEGER
  fcvRvpConnCos INTEGER
  fcvRvpConnBe INTEGER

FcsnaLvpLocalLanPuEntry  
SEQUENCE    
  fcsnaLvpLlpVirtualPortId INTEGER
  fcsnaLvpLlpPuId INTEGER
  fcsnaLvpLlpStatus INTEGER

FcsnaGpRoutingEntry  
SEQUENCE    
  fcsnaGpRoutClusterPuId INTEGER
  fcsnaGpRoutHostPuId INTEGER
  fcsnaGpRoutStatus INTEGER
  fcsnaGpRoutDsap OCTET STRING
  fcsnaGpRoutSsap OCTET STRING
  fcsnaGpRoutCos INTEGER
  fcsnaGpRoutCir INTEGER
  fcsnaGpRoutCirmin INTEGER
  fcsnaGpRoutBc INTEGER
  fcsnaGpRoutBe INTEGER

FcsnaGpRemotePuEntry  
SEQUENCE    
  fcsnaGpRemPuPuId INTEGER
  fcsnaGpRemPuStatus INTEGER
  fcsnaGpRemPuProtocol INTEGER

FcsnaGpSdlcEntry  
SEQUENCE    
  fcsnaGpSdlcPuId INTEGER
  fcsnaGpSdlcStatus INTEGER
  fcsnaGpSdlcLp INTEGER
  fcsnaGpSdlcCluster OCTET STRING

FcsnaGpX25Entry  
SEQUENCE    
  fcsnaGpX25PuId INTEGER
  fcsnaGpX25Status INTEGER
  fcsnaGpX25Address OCTET STRING

FcsnaGpLanFrEntry  
SEQUENCE    
  fcsnaGpLanFrPuId INTEGER
  fcsnaGpLanFrStatus INTEGER
  fcsnaGpLanFrMacAddress OCTET STRING

FcbBrdgVirtualPortEntry  
SEQUENCE    
  fcbBrdgVpVirtualPortId INTEGER
  fcbBrdgVpStatus INTEGER
  fcbBrdgVpAgingTime INTEGER
  fcbBrdgVpBroadcasting INTEGER
  fcbBrdgVpFcsPreservation INTEGER

FcbBrdgRemoteAddressMappingEntry  
SEQUENCE    
  fcbBrdgMapMacAddress OCTET STRING
  fcbBrdgMapStatus INTEGER
  fcbBrdgMapRemoteAddress OCTET STRING

FcbStpVirtualPortEntry  
SEQUENCE    
  fcbStpVpVirtualPortId INTEGER
  fcbStpVpPortPriority INTEGER
  fcbStpVpPortPathCost INTEGER
  fcbStpVpBpduEncapsulation INTEGER

FciVirtualPortEntry  
SEQUENCE    
  fciVpVirtualPortId INTEGER
  fciVpStatus INTEGER
  fciVpIpAddress IpAddress
  fciVpNetMask IpAddress
  fciVpMtu INTEGER
  fciVpProxyArp INTEGER
  fciVpInverseArp INTEGER

FciLocalVirtualPortEntry  
SEQUENCE    
  fciLvpVirtualPortId INTEGER
  fciLvpStatus INTEGER
  fciLvpEncapsulation INTEGER

FciLocalClusterEntry  
SEQUENCE    
  fciLclVirtualPortId INTEGER
  fciLclClusterNumber INTEGER
  fciLclStatus INTEGER
  fciLclVirtualIpAddress IpAddress
  fciLclPriority INTEGER

FciRemoteNetToMediaEntry  
SEQUENCE    
  fciRemIpAddress IpAddress
  fciRemStatus INTEGER
  fciRemRemoteAddress OCTET STRING

FciNetToMediaEntry  
SEQUENCE    
  fciNetToMediaIpAddress IpAddress
  fciNetToMediaStatus INTEGER
  fciNetToMediaMacAddress OCTET STRING

FciIpRouteEntry  
SEQUENCE    
  fciRouteDest IpAddress
  fciRouteMask IpAddress
  fciRouteStatus INTEGER
  fciRouteNextHop IpAddress
  fciRouteMetric INTEGER

FciFlowEntry  
SEQUENCE    
  fciFlowFlowId INTEGER
  fciFlowStatus INTEGER
  fciFlowType INTEGER
  fciFlowVpId INTEGER
  fciFlowSrcIpAddress IpAddress
  fciFlowSrcMask IpAddress
  fciFlowDestIpAddress IpAddress
  fciFlowDestMask IpAddress
  fciFlowProtocol INTEGER
  fciFlowPortMin INTEGER
  fciFlowPortMax INTEGER
  fciFlowLengthMax INTEGER
  fciFlowSegmented INTEGER

FciFlowAddrSubstituteEntry  
SEQUENCE    
  fciFlowSubstFlowId INTEGER
  fciFlowSubstDestIpAddress IpAddress
  fciFlowSubstStatus INTEGER

FciFlowRouteEntry  
SEQUENCE    
  fciFlowRouteFlowId INTEGER
  fciFlowRouteStatus INTEGER
  fciFlowRouteNextHop IpAddress

FciRipVirtualPortEntry  
SEQUENCE    
  fciRipVpVirtualPortId INTEGER
  fciRipVpDistribution INTEGER
  fciRipVpMetricOut INTEGER
  fciRipVpRipIn INTEGER
  fciRipVpMetricIn INTEGER
  fciRipVpVersion INTEGER
  fciRipVpMulticast INTEGER
  fciRipVpAuthType INTEGER
  fciRipVpAuthKey DisplayString

FciRipNeighborEntry  
SEQUENCE    
  fciRipNeighborIpAddress IpAddress
  fciRipNeighborStatus INTEGER
  fciRipNeighborOutput INTEGER
  fciRipNeighborInput INTEGER
  fciRipNeighborBackupGroup INTEGER

FciRipEgpRoutesDistributionEntry  
SEQUENCE    
  fciRipEgpRoutesAsNumber INTEGER
  fciRipEgpRoutesStatus INTEGER
  fciRipEgpRoutesMetric INTEGER

FciOspfVirtualPortsEntry  
SEQUENCE    
  fciOspfVpId INTEGER
  fciOspfVpAdminStatus INTEGER
  fciOspfVpAreaId IpAddress
  fciOspfVpMetric INTEGER
  fciOspfVpType INTEGER
  fciOspfVpDRPriority INTEGER
  fciOspfVpTransitDelay INTEGER
  fciOspfVpRetransmitInterval INTEGER
  fciOspfVpHelloInterval INTEGER
  fciOspfVpRouterDeadInterval INTEGER
  fciOspfVpPollInterval INTEGER
  fciOspfVpAuthenticationKey DisplayString

FciOspfNeighborsEntry  
SEQUENCE    
  fciOspfNeighborIpAddress IpAddress
  fciOspfNeighborStatus INTEGER
  fciOspfNeighborEligibleStatus INTEGER

FciOspfAreasEntry  
SEQUENCE    
  fciOspfAreaId IpAddress
  fciOspfAreaStatus INTEGER
  fciOspfAreaAuthType INTEGER
  fciOspfAreaStubStatus INTEGER
  fciOspfAreaStubMetric INTEGER

FciOspfAreaRangesEntry  
SEQUENCE    
  fciOspfAreaRangeIpAddress IpAddress
  fciOspfAreaRangeIpMask IpAddress
  fciOspfAreaRangeStatus INTEGER
  fciOspfAreaRangeAreaId IpAddress
  fciOspfAreaRangeRestrict INTEGER

FciOspfVirtualLinksEntry  
SEQUENCE    
  fciOspfVlNeighborId IpAddress
  fciOspfVlTransitAreaId IpAddress
  fciOspfVlStatus INTEGER
  fciOspfVlDRPriority INTEGER
  fciOspfVlTransitDelay INTEGER
  fciOspfVlRetransmitInterval INTEGER
  fciOspfVlHelloInterval INTEGER
  fciOspfVlRouterDeadInterval INTEGER
  fciOspfVlAuthenticationKey DisplayString

FciEgpNeighborEntry  
SEQUENCE    
  fciEgpNeighborIpAddress IpAddress
  fciEgpNeighborStatus INTEGER
  fciEgpNeighborAsNumber INTEGER

FciEgpTargetAsDistributionEntry  
SEQUENCE    
  fciEgpTargetAsNumber INTEGER
  fciEgpTargetAsStatus INTEGER

FciSnmpManagerEntry  
SEQUENCE    
  fciSnmpManagerIpAddress IpAddress
  fciSnmpManagerStatus INTEGER
  fciSnmpManagerSendTraps INTEGER
  fciSnmpManagerTrapsUdpPort INTEGER

FciBootPInterfaceEntry  
SEQUENCE    
  fciBootPInterfaceVpId INTEGER
  fciBootPInterfaceIpAddress IpAddress
  fciBootPInterfaceStatus INTEGER
  fciBootPInterfaceType INTEGER

FciTelnetUserEntry  
SEQUENCE    
  fciTelnetUserId INTEGER
  fciTelnetUserStatus INTEGER
  fciTelnetUserLogin DisplayString
  fciTelnetUserPriority INTEGER

FcxCircuitEntry  
SEQUENCE    
  fcxCircCircuitId INTEGER
  fcxCircStatus INTEGER
  fcxCircVirtualPortId INTEGER
  fcxCircOperState INTEGER
  fcxCircName DisplayString
  fcxCircType INTEGER
  fcxCircLocalMaxPacketSize INTEGER
  fcxCircNetNumber OCTET STRING
  fcxCircChecksumEnabling INTEGER

FcxCircuitLocalVpEntry  
SEQUENCE    
  fcxCircLvpCircuitId INTEGER
  fcxCircLvpStatus INTEGER
  fcxCircLvpEncapsulation INTEGER

FcxCircuitRemoteVpEntry  
SEQUENCE    
  fcxCircRvpCircuitId INTEGER
  fcxCircRvpStatus INTEGER
  fcxCircRvpRemoteAddress OCTET STRING
  fcxCircRvpLocalNode OCTET STRING

FcxRoutCircuitEntry  
SEQUENCE    
  fcxRoutCircCircuitId INTEGER
  fcxRoutCircNcpSpoofing INTEGER
  fcxRoutCircType20PacketBroadcasting INTEGER
  fcxRoutCircAddressFiltering INTEGER

FcxRoutIpxStaticRouteEntry  
SEQUENCE    
  fcxRoutStaticRouteCircuitId INTEGER
  fcxRoutStaticRouteNetNum OCTET STRING
  fcxRoutStaticRouteStatus INTEGER
  fcxRoutStaticRouteTicks INTEGER
  fcxRoutStaticRouteHopCount INTEGER

FcxRoutAddressFilteringEntry  
SEQUENCE    
  fcxRoutAddrFltCircuitId INTEGER
  fcxRoutAddrFltFilterId INTEGER
  fcxRoutAddrFltStatus INTEGER
  fcxRoutAddrFltFiltering INTEGER
  fcxRoutAddrFltField INTEGER
  fcxRoutAddrFltMask OCTET STRING
  fcxRoutAddrFltValue OCTET STRING

FcxRipCircuitEntry  
SEQUENCE    
  fcxRipCircCircuitId INTEGER
  fcxRipCircState INTEGER
  fcxRipCircPace INTEGER
  fcxRipCircUpdate INTEGER
  fcxRipCircAgeMultiplier INTEGER
  fcxRipCircPacketSize INTEGER
  fcxRipCircOutputFiltering INTEGER

FcxRipInputFilteringEntry  
SEQUENCE    
  fcxRipInFltFilterId INTEGER
  fcxRipInFltStatus INTEGER
  fcxRipInFltFiltering INTEGER
  fcxRipInFltNetAddress OCTET STRING
  fcxRipInFltMask OCTET STRING

FcxRipOutputFilteringEntry  
SEQUENCE    
  fcxRipOutFltCircuitId INTEGER
  fcxRipOutFltFilterId INTEGER
  fcxRipOutFltStatus INTEGER
  fcxRipOutFltFiltering INTEGER
  fcxRipOutFltNetAddress OCTET STRING
  fcxRipOutFltMask OCTET STRING

FcxServCircuitEntry  
SEQUENCE    
  fcxServCircSapCircuitId INTEGER
  fcxServCircSapState INTEGER
  fcxServCircSapPace INTEGER
  fcxServCircSapUpdate INTEGER
  fcxServCircSapAgeMultiplier INTEGER
  fcxServCircSapPacketSize INTEGER
  fcxServCircSapGetNearestServerReply INTEGER
  fcxServCircSapOutputFiltering INTEGER

FcxServStaticServiceEntry  
SEQUENCE    
  fcxServStaticServiceId INTEGER
  fcxServStaticStatus INTEGER
  fcxServStaticCircuitId INTEGER
  fcxServStaticName DisplayString
  fcxServStaticType OCTET STRING
  fcxServStaticNetNum OCTET STRING
  fcxServStaticNode OCTET STRING
  fcxServStaticSocket OCTET STRING
  fcxServStaticHopCount INTEGER

FcxServSapInputFilteringEntry  
SEQUENCE    
  fcxServSapInFltFilterId INTEGER
  fcxServSapInFltStatus INTEGER
  fcxServSapInFltFiltering INTEGER
  fcxServSapInFltCheckedField INTEGER
  fcxServSapInFltServiceNameType INTEGER
  fcxServSapInFltServiceName DisplayString
  fcxServSapInFltServiceType OCTET STRING

FcxServSapOutputFilteringEntry  
SEQUENCE    
  fcxServSapOutFltCircuitId INTEGER
  fcxServSapOutFltFilterId INTEGER
  fcxServSapOutFltStatus INTEGER
  fcxServSapOutFltFiltering INTEGER
  fcxServSapOutFltCheckedField INTEGER
  fcxServSapOutFltServiceNameType INTEGER
  fcxServSapOutFltServiceName DisplayString
  fcxServSapOutFltServiceType OCTET STRING

FccVirtualPortEntry  
SEQUENCE    
  fccVpVirtualPortId INTEGER
  fccVpStatus INTEGER
  fccVpMtu INTEGER

FccLocalVirtualPortEntry  
SEQUENCE    
  fccLvpVirtualPortId INTEGER
  fccLvpStatus INTEGER
  fccLvpEsIsRedirection INTEGER
  fccLvpEsIsConfigTimer INTEGER
  fccLvpEsIsHoldingTimer INTEGER

FccNeighborEntry  
SEQUENCE    
  fccNeighNeighborId INTEGER
  fccNeighStatus INTEGER
  fccNeighType INTEGER
  fccNeighVirtualPortId INTEGER
  fccNeighClnpAddress OCTET STRING

FccLocalNeighborEntry  
SEQUENCE    
  fccLneighNeighborId INTEGER
  fccLneighStatus INTEGER
  fccLneighMacAddress OCTET STRING

FccRemoteNeighborEntry  
SEQUENCE    
  fccRneighNeighborId INTEGER
  fccRneighStatus INTEGER
  fccRneighRemoteAddress OCTET STRING

FccClnpRouteEntry  
SEQUENCE    
  fccRoutRouteId INTEGER
  fccRoutStatus INTEGER
  fccRoutDestClnpAddress OCTET STRING
  fccRoutNextHopNeighborId INTEGER

FmeTroubleReportInfoEntry  
SEQUENCE    
  fmeTrblInfoIndex INTEGER
  fmeTrblInfoData DisplayString

FmeFamilyEntry  
SEQUENCE    
  fmeFamFamilyId INTEGER
  fmeFamStoredEventsCount INTEGER
  fmeFamStoredEventsCommand INTEGER

FmeEventEntry  
SEQUENCE    
  fmeEvtFamilyId INTEGER
  fmeEvtEventIndex INTEGER
  fmeEvtEventType OCTET STRING
  fmeEvtTime TimeTicks
  fmeEvtLineId INTEGER
  fmeEvtData DisplayString

FmStatLineEntry  
SEQUENCE    
  fmsLineId INTEGER
  fmsLineState INTEGER
  fmsLineLcInUseCount Gauge
  fmsLineReinitsCounter Counter
  fmsLineIncidentsCounter INTEGER
  fmsLineInputOctetsCounter Counter
  fmsLineOutputOctetsCounter Counter
  fmsLineType INTEGER
  fmsLineTestState INTEGER

FmStatSignalEntry  
SEQUENCE    
  fmsSigPhysPortId INTEGER
  fmsSigState INTEGER
  fmsSigDceOrDte INTEGER
  fmsSig105 INTEGER
  fmsSig106 INTEGER
  fmsSig107 INTEGER
  fmsSig108 INTEGER
  fmsSig109 INTEGER
  fmsSig111 INTEGER
  fmsSig125 INTEGER
  fmsSig140 INTEGER
  fmsSig141 INTEGER
  fmsSig142 INTEGER
  fmsSigSyn INTEGER

FmStatStateEntry  
SEQUENCE    
  fmsStateLine INTEGER
  fmsStateLineType INTEGER
  fmsStateOsiState INTEGER
  fmsStateTestState INTEGER
  fmsStateMlpTrunkMainLine INTEGER
  fmsStateMlpTrunkNumber INTEGER
  fmsStateMlpTrunkState INTEGER

FmStatMlpEntry  
SEQUENCE    
  fmsMlpTrunkNumber INTEGER
  fmsMlpLineId INTEGER
  fmsMlpLineType INTEGER

FmStatEthernetEntry  
SEQUENCE    
  fmsEthLineId INTEGER
  fmsEthPhysAddr OCTET STRING
  fmsEthOperStatus INTEGER
  fmsEthInterface INTEGER
  fmsEthAutoPortSelection INTEGER
  fmsEthPolarityCorrection INTEGER
  fmsEthPolarityInversion INTEGER
  fmsEthLinkIntegrity INTEGER
  fmsEthTestLoopback INTEGER
  fmsEthJabber INTEGER
  fmsEthTestMode INTEGER
  fmsEthTdrState INTEGER
  fmsEthTdrLoc INTEGER
  fmsEthUpTime TimeTicks

FmStatEthInputTrafficEntry  
SEQUENCE    
  fmsEthInLineId INTEGER
  fmsEthInOctetsCounter Counter
  fmsEthInPktsCounter Counter
  fmsEthInNoErrCounter Counter
  fmsEthInUcastPktsCounter Counter
  fmsEthInAlignmentErrorsCounter Counter
  fmsEthInFCSErrorsCounter Counter
  fmsEthInPktsTooLongsCounter Counter
  fmsEthInPktsTooShortsCounter Counter
  fmsEthInErrOutOfResourcesCounter Counter
  fmsEthInErrDmaOverrunCounter Counter
  fmsEthInErrCollCounter Counter
  fmsEthInErrOverFlowCounter Counter

FmStatEthOutputTrafficEntry  
SEQUENCE    
  fmsEthOutLineId INTEGER
  fmsEthOutOctetsCounter Counter
  fmsEthOutPktsCounter Counter
  fmsEthOutNoErrCounter Counter
  fmsEthOutSingleCollisionFramesCounter Counter
  fmsEthOutMultipleCollisionFramesCounter Counter
  fmsEthOutDeferredTransmissionsCounter Counter
  fmsEthOutSQETestErrorsCounter Counter
  fmsEthOutLateCollisionsCounter Counter
  fmsEthOutExcessiveCollisionsCounter Counter
  fmsEthOutCarrierSenseErrorsCounter Counter
  fmsEthOutErrExcdDelayCounter Counter
  fmsEthOutErrCtsLossCounter Counter
  fmsEthOutErrDmaUnderrunCounter Counter

FmStatEthManagementEntry  
SEQUENCE    
  fmsEthManLineId INTEGER
  fmsEthManSupervisionOkCounter Counter
  fmsEthManSupervisionNokCounter Counter
  fmsEthManInputResetCounter Counter
  fmsEthManFilterPermitCounter Counter
  fmsEthManFilterDenyCounter Counter

FmStatWanConnectionsEntry  
SEQUENCE    
  fmsWanConnId INTEGER
  fmsWanConnRemoteAddr OCTET STRING
  fmsWanConnEncapsulation INTEGER
  fmsWanConnStatus INTEGER
  fmsWanConnGrouping INTEGER
  fmsWanConnLocalSbNumber INTEGER
  fmsWanConnInPktsCounter Counter
  fmsWanConnInErrPktsCounter Counter
  fmsWanConnInOctetsCounter Counter
  fmsWanConnOutPktsCounter Counter
  fmsWanConnOutOctetsCounter Counter

FmStatRvpConnectionsEntry  
SEQUENCE    
  fmsRvpConnRemoteAddr OCTET STRING
  fmsRvpConnEncapsulation INTEGER
  fmsRvpConnId INTEGER
  fmsRvpConnStatus INTEGER
  fmsRvpConnGrouping INTEGER
  fmsRvpConnLocalSbNumber INTEGER
  fmsRvpConnInPktsCounter Counter
  fmsRvpConnInErrPktsCounter Counter
  fmsRvpConnInOctetsCounter Counter
  fmsRvpConnOutPktsCounter Counter
  fmsRvpConnOutOctetsCounter Counter

FmStatIpClusterStateEntry  
SEQUENCE    
  fmsIpCluVpId INTEGER
  fmsIpCluClusterNumber INTEGER
  fmsIpCluVirtualIpAddress IpAddress
  fmsIpCluOperStatus INTEGER
  fmsIpCluAdminStatus INTEGER
  fmsIpCluLastChange TimeTicks

FmsFrLpLogPortEntry  
SEQUENCE    
  fmsFrLpLogPortId INTEGER
  fmsFrLpInterfaceType INTEGER
  fmsFrLpNumPlan INTEGER
  fmsFrLpAddrDlciLen INTEGER
  fmsFrLpVcSigProtocol INTEGER

FmsFrLpIncomingEntry  
SEQUENCE    
  fmsFrLpInLogPortId INTEGER
  fmsFrLpInOctets Counter
  fmsFrLpInFrames Counter
  fmsFrLpInErrors Counter
  fmsFrLpInFrHeaderErrors Counter
  fmsFrLpInFecnFrames Counter
  fmsFrLpInBecnFrames Counter
  fmsFrLpInExcessFrames Counter
  fmsFrLpInDiscards Counter

FmsFrLpOutgoingEntry  
SEQUENCE    
  fmsFrLpOutLogPortId INTEGER
  fmsFrLpOutOctets Counter
  fmsFrLpOutFrames Counter
  fmsFrLpOutFecnFrames Counter
  fmsFrLpOutLocalCongFecnFrames Counter
  fmsFrLpOutBecnFrames Counter
  fmsFrLpOutLocalCongBecnFrames Counter
  fmsFrLpOutLocalCongDiscards Counter

FmsFrLpLmiEntry  
SEQUENCE    
  fmsFrLpLmiLogPortId INTEGER
  fmsFrLpLmiProced INTEGER
  fmsFrLpLmiUserN391 INTEGER
  fmsFrLpLmiUserN392 INTEGER
  fmsFrLpLmiUserN393 INTEGER
  fmsFrLpLmiUserT391 INTEGER
  fmsFrLpLmiNetN392 INTEGER
  fmsFrLpLmiNetN393 INTEGER
  fmsFrLpLmiNetT392 INTEGER
  fmsFrLpLmiUserLinkRelErrors Counter
  fmsFrLpLmiUserProtErrors Counter
  fmsFrLpLmiUserChanInactive Counter
  fmsFrLpLmiNetLinkRelErrors Counter
  fmsFrLpLmiNetProtErrors Counter
  fmsFrLpLmiNetChanInactive Counter

FmsFrLpSvcSignallingEntry  
SEQUENCE    
  fmsFrLpSvcLogPortId INTEGER
  fmsFrLpSvcDlcInitialized Gauge
  fmsFrLpSvcDlcUbr Gauge
  fmsFrLpSvcDlcVbr Gauge
  fmsFrLpSvcDlcVbrRt Gauge
  fmsFrLpSvcBookingVbrThroughput Gauge
  fmsFrLpSvcBookingVbrRtThroughput Gauge
  fmsFrLpSvcOverBookingThroughput Gauge
  fmsFrLpSvcBookingRate Gauge

FmsFrDlcEntry  
SEQUENCE    
  fmsFrDlcLogPortId INTEGER
  fmsFrDlcDlci INTEGER
  fmsFrDlcState INTEGER
  fmsFrDlcRcvdSigStatus INTEGER
  fmsFrDlcCos INTEGER

FmsFrDlcIncomingEntry  
SEQUENCE    
  fmsFrDlcInLogPortId INTEGER
  fmsFrDlcInDlci INTEGER
  fmsFrDlcInFrames Counter
  fmsFrDlcInOctets Counter
  fmsFrDlcInDeFrames Counter
  fmsFrDlcInFecnFrames Counter
  fmsFrDlcInBecnFrames Counter
  fmsFrDlcInExcessFrames Counter
  fmsFrDlcInDiscards Counter
  fmsFrDlcInLostFrames Counter
  fmsFrDlcInLostSegments Counter

FmsFrDlcOutgoingEntry  
SEQUENCE    
  fmsFrDlcOutLogPortId INTEGER
  fmsFrDlcOutDlci INTEGER
  fmsFrDlcOutFrames Counter
  fmsFrDlcOutOctets Counter
  fmsFrDlcOutFecnFrames Counter
  fmsFrDlcOutBecnFrames Counter
  fmsFrDlcOutExcessFrames Counter
  fmsFrDlcOutDiscards Counter

FmStatFrLineEntry  
SEQUENCE    
  fmsFrLineId INTEGER
  fmsFrLineStatus INTEGER
  fmsFrLineLmiStatus INTEGER
  fmsFrLineCircuitCount Gauge
  fmsFrLineActiveCircuitCount Gauge

FmStatFrCircuitEntry  
SEQUENCE    
  fmsFrCircuitLineId INTEGER
  fmsFrCircuitDlci INTEGER
  fmsFrCircuitStatus INTEGER
  fmsFrCircuitAge INTEGER
  fmsFrCircuitOutOctetsCounter Counter
  fmsFrCircuitInOctetsCounter Counter

FmsFrCommStorageEntry  
SEQUENCE    
  fmsFrcStoragePhysIfId INTEGER
  fmsFrcStorageChannelId INTEGER
  fmsFrcStorageDlci INTEGER
  fmsFrcStorageSubDlci INTEGER
  fmsFrcStorageTypeOfDlci INTEGER
  fmsFrcStorageDirection OCTET STRING
  fmsFrcStorageTypeOfTransport INTEGER
  fmsFrcStoragePvcStatus INTEGER
  fmsFrcStorageDestAddr OCTET STRING
  fmsFrcStorageSrcAddr OCTET STRING
  fmsFrcStorageCos INTEGER
  fmsFrcStorageCir INTEGER
  fmsFrcStorageMinCir INTEGER
  fmsFrcStorageBc INTEGER
  fmsFrcStorageBe INTEGER

FmStatPppPhysLineEntry  
SEQUENCE    
  fmsPppPhysLineId INTEGER
  fmsPppPhysLocalMru INTEGER
  fmsPppPhysRemoteMru INTEGER
  fmsPppPhysMagicNumber INTEGER

FmStatPppProtocolStatusEntry  
SEQUENCE    
  fmsPppProtoLineId INTEGER
  fmsPppProtoLcpStatus INTEGER
  fmsPppProtoLcpDiag INTEGER
  fmsPppProtoIpNcpStatus INTEGER
  fmsPppProtoIpNcpDiag INTEGER
  fmsPppProtoBrdgNcpStatus INTEGER
  fmsPppProtoBrdgNcpDiag INTEGER
  fmsPppProtoIpxNcpStatus INTEGER
  fmsPppProtoIpxNcpDiag INTEGER
  fmsPppProtoClnpNcpStatus INTEGER
  fmsPppProtoClnpNcpDiag INTEGER

FmStatPppAuthenticationEntry  
SEQUENCE    
  fmsPppAuthLineId INTEGER
  fmsPppAuthMasterAuthentication INTEGER
  fmsPppAuthMasterSuccessCounter Counter
  fmsPppAuthMasterFailureCounter Counter
  fmsPppAuthSlaveAuthentication INTEGER
  fmsPppAuthSlaveSuccessCounter Counter
  fmsPppAuthSlaveFailureCounter Counter

FmStatPppIpAddrAssignmentEntry  
SEQUENCE    
  fmsPppIpAddrLineId INTEGER
  fmsPppIpAddrReceived IpAddress
  fmsPppIpAddrSent IpAddress

FmStatE1Ds1ChannelEntry  
SEQUENCE    
  fmsE1Ds1ChIfPhysId INTEGER
  fmsE1Ds1ChIfChannelId INTEGER
  fmsE1Ds1ChIfType INTEGER
  fmsE1Ds1ChIfDescr DisplayString
  fmsE1Ds1ChIfMtu INTEGER
  fmsE1Ds1ChIfSpeed INTEGER
  fmsE1Ds1ChIfPhysAddress OCTET STRING
  fmsE1Ds1ChIfAdminStatus INTEGER
  fmsE1Ds1ChIfOperStatus INTEGER
  fmsE1Ds1ChIfLastChange TimeTicks
  fmsE1Ds1ChIfInOctets Counter
  fmsE1Ds1ChIfInUcastPkts Counter
  fmsE1Ds1ChIfInNUcastPkts Counter
  fmsE1Ds1ChIfInDiscards Counter
  fmsE1Ds1ChIfInErrors Counter
  fmsE1Ds1ChIfInUnknownProtos Counter
  fmsE1Ds1ChIfOutOctets Counter
  fmsE1Ds1ChIfOutUcastPkts Counter
  fmsE1Ds1ChIfOutNUcastPkts Counter
  fmsE1Ds1ChIfOutDiscards Counter
  fmsE1Ds1ChIfOutErrors Counter
  fmsE1Ds1ChIfOutQLen Gauge
  fmsE1Ds1ChIfSpecific INTEGER

FmStatS2BChannelEntry  
SEQUENCE    
  fmsS2BChPhysIfId INTEGER
  fmsS2BChChannelId INTEGER
  fmsS2BChProto INTEGER
  fmsS2BChIfSpeed INTEGER
  fmsS2BChAdminStatus INTEGER
  fmsS2BChOperStatus INTEGER
  fmsS2BChIfLastChange TimeTicks
  fmsS2BChIfInOctets Counter
  fmsS2BChIfOutOctets Counter
  fmsS2BChIfCalledAddress OCTET STRING
  fmsS2BChIfCallingAddress OCTET STRING

FmStatS0BChannelEntry  
SEQUENCE    
  fmsS0BChPhysIfId INTEGER
  fmsS0BChChannelId INTEGER
  fmsS0BChProto INTEGER
  fmsS0BChIfSpeed INTEGER
  fmsS0BChAdminStatus INTEGER
  fmsS0BChOperStatus INTEGER
  fmsS0BChIfLastChange TimeTicks
  fmsS0BChIfInOctets Counter
  fmsS0BChIfOutOctets Counter
  fmsS0BChIfCalledAddress OCTET STRING
  fmsS0BChIfCallingAddress OCTET STRING

FmOsiCLNPCircuitEntry  
SEQUENCE    
  fmOsiCLNPCircIndex INTEGER
  fmOsiCLNPCircOutPDUs Counter
  fmOsiCLNPCircInPDUs Counter

FmOsiESISCircuitEntry  
SEQUENCE    
  fmOsiESISCircIndex INTEGER
  fmOsiESISCircOutPDUs Counter
  fmOsiESISCircInPDUs Counter

FmOsiISISCircuitEntry  
SEQUENCE    
  fmOsiISISCircIndex INTEGER
  fmOsiISISCircOutPdu Counter
  fmOsiISISCircInPdu Counter
  fmOsiISISCircAdjChanges Counter
  fmOsiISISCircInitFails Counter
  fmOsiISISCircRejAdjs Counter
  fmOsiISISCircOutCtrlPdu Counter
  fmOsiISISCircInCrtlPdu Counter
  fmOsiISISCircIDFieldLenMismatches Counter
  fmOsiISISCircMaxAreaAddrMismatches Counter
  fmOsiISISCircL1DesIS DisplayString
  fmOsiISISCircLANL1DesISChanges Counter
  fmOsiISISCircL2DesIS DisplayString
  fmOsiISISCircLANL2DesISChanges Counter
  fmOsiISISCircAuthFails Counter

FmOsiISISAreaEntry  
SEQUENCE    
  fmOsiISISAreaAddress DisplayString

FmOsiISISISAdjacencyEntry  
SEQUENCE    
  fmOsiISISISAdjCircIndex INTEGER
  fmOsiISISISAdjIndex INTEGER
  fmOsiISISISAdjSysID DisplayString
  fmOsiISISISAdjState INTEGER
  fmOsiISISISAdjSNPAAddress DisplayString
  fmOsiISISISAdjType INTEGER
  fmOsiISISISAdjUsage INTEGER
  fmOsiISISISAdjHoldTimer INTEGER
  fmOsiISISISAdjPriority INTEGER

FmOsiISISISAdjacencyAreaAddressEntry  
SEQUENCE    
  fmOsiISISISAdjAreaAddrCircIndex INTEGER
  fmOsiISISISAdjAreaAddrAdjIndex INTEGER
  fmOsiISISISAdjAreaAddress DisplayString

FmOsiISISESAdjacencyEntry  
SEQUENCE    
  fmOsiISISESAdjCircIndex INTEGER
  fmOsiISISESAdjAdjIndex INTEGER
  fmOsiISISESAdjESID DisplayString
  fmOsiISISESAdjState INTEGER
  fmOsiISISESAdjNeighSNPAAdress DisplayString
  fmOsiISISESAdjType INTEGER

FmOsiISISReachableAddressEntry  
SEQUENCE    
  fmOsiISISRASystemType INTEGER
  fmOsiISISRAAddress DisplayString
  fmOsiISISRAMetric INTEGER
  fmOsiISISRAPathIdentifier INTEGER
  fmOsiISISRAType INTEGER
  fmOsiISISRACircuitId INTEGER
  fmOsiISISRAAdjacencyId INTEGER
  fmOsiISISRAPathCost INTEGER
  fmOsiISISRASNPAAddress DisplayString

FmPingEntry  
SEQUENCE    
  fmPingIdentifier INTEGER
  fmPingProtocol INTEGER
  fmPingAddress DisplayString
  fmPingCountRequest INTEGER
  fmPingPacketSize INTEGER
  fmPingDelay INTEGER
  fmPingTimeout INTEGER
  fmPingPermanent INTEGER
  fmPingSentPackets Counter
  fmPingReceivedPackets Counter
  fmPingMinRoundTrip INTEGER
  fmPingAvgRoundTrip INTEGER
  fmPingMaxRoundTrip INTEGER
  fmPingCompletedFlag INTEGER
  fmPingOwner DisplayString
  fmPingAdminState INTEGER

FmRip2IfStatEntry  
SEQUENCE    
  fmRip2IfStatAddress IpAddress
  fmRip2IfStatRcvBadPackets Counter
  fmRip2IfStatRcvBadRoutes Counter
  fmRip2IfStatSentUpdates Counter
  fmRip2IfStatStatus INTEGER

FmRip2IfConfEntry  
SEQUENCE    
  fmRip2IfConfAddress IpAddress
  fmRip2IfConfDomain DisplayString
  fmRip2IfConfAuthType INTEGER
  fmRip2IfConfAuthKey DisplayString
  fmRip2IfConfSend INTEGER
  fmRip2IfConfReceive INTEGER
  fmRip2IfConfDefaultMetric INTEGER
  fmRip2IfConfStatus INTEGER

FmRip2PeerEntry  
SEQUENCE    
  fmRip2PeerAddress IpAddress
  fmRip2PeerDomain DisplayString
  fmRip2PeerLastUpdate TimeTicks
  fmRip2PeerVersion INTEGER
  fmRip2PeerRcvBadPackets Counter
  fmRip2PeerRcvBadRoutes Counter

FmOspfStandardAreaEntry  
SEQUENCE    
  fmOspfStandardAreaId IpAddress
  fmOspfStandardAuthType INTEGER
  fmOspfStandardImportASExtern INTEGER
  fmOspfStandardSpfRuns Counter
  fmOspfStandardAreaBdrRtrCount Gauge
  fmOspfStandardASBdrRtrCount Gauge
  fmOspfStandardAreaLSACount Gauge
  fmOspfStandardAreaLSACksumSum INTEGER

FmOspfStandardStubAreaEntry  
SEQUENCE    
  fmOspfStandardStubAreaID IpAddress
  fmOspfStandardStubTOS INTEGER
  fmOspfStandardStubMetric INTEGER
  fmOspfStandardStubStatus INTEGER

FmOspfStandardLsdbEntry  
SEQUENCE    
  fmOspfStandardLsdbAreaId IpAddress
  fmOspfStandardLsdbType INTEGER
  fmOspfStandardLsdbLSID IpAddress
  fmOspfStandardLsdbRouterId IpAddress
  fmOspfStandardLsdbSequence INTEGER
  fmOspfStandardLsdbAge INTEGER
  fmOspfStandardLsdbChecksum INTEGER
  fmOspfStandardLsdbAdvertisement DisplayString

FmOspfStandardAreaRangeEntry  
SEQUENCE    
  fmOspfStandardAreaRangeAreaID IpAddress
  fmOspfStandardAreaRangeNet IpAddress
  fmOspfStandardAreaRangeMask IpAddress
  fmOspfStandardAreaRangeStatus INTEGER

FmOspfStandardHostEntry  
SEQUENCE    
  fmOspfStandardHostIpAddress IpAddress
  fmOspfStandardHostTOS INTEGER
  fmOspfStandardHostMetric INTEGER
  fmOspfStandardHostStatus INTEGER

FmOspfStandardIfEntry  
SEQUENCE    
  fmOspfStandardIfIpAddress IpAddress
  fmOspfStandardAddressLessIf INTEGER
  fmOspfStandardIfAreaId IpAddress
  fmOspfStandardIfType INTEGER
  fmOspfStandardIfAdminStat INTEGER
  fmOspfStandardIfRtrPriority INTEGER
  fmOspfStandardIfTransitDelay INTEGER
  fmOspfStandardIfRetransInterval INTEGER
  fmOspfStandardIfHelloInterval INTEGER
  fmOspfStandardIfRtrDeadInterval INTEGER
  fmOspfStandardIfPollInterval INTEGER
  fmOspfStandardIfState INTEGER
  fmOspfStandardIfDesignatedRouter IpAddress
  fmOspfStandardIfBackupDesignatedRouter IpAddress
  fmOspfStandardIfEvents Counter
  fmOspfStandardIfAuthKey DisplayString

FmOspfStandardIfMetricEntry  
SEQUENCE    
  fmOspfStandardIfMetricIpAddress IpAddress
  fmOspfStandardIfMetricAddressLessIf INTEGER
  fmOspfStandardIfMetricTOS INTEGER
  fmOspfStandardIfMetricMetric INTEGER
  fmOspfStandardIfMetricStatus INTEGER

FmOspfStandardVirtIfEntry  
SEQUENCE    
  fmOspfStandardVirtIfAreaID IpAddress
  fmOspfStandardVirtIfNeighbor IpAddress
  fmOspfStandardVirtIfTransitDelay INTEGER
  fmOspfStandardVirtIfRetransInterval INTEGER
  fmOspfStandardVirtIfHelloInterval INTEGER
  fmOspfStandardVirtIfRtrDeadInterval INTEGER
  fmOspfStandardVirtIfState INTEGER
  fmOspfStandardVirtIfEvents Counter
  fmOspfStandardVirtIfAuthKey DisplayString
  fmOspfStandardVirtIfStatus INTEGER

FmOspfStandardNbrEntry  
SEQUENCE    
  fmOspfStandardNbrIpAddress IpAddress
  fmOspfStandardNbrAddressLessIndex INTEGER
  fmOspfStandardNbrRtrId IpAddress
  fmOspfStandardNbrOptions INTEGER
  fmOspfStandardNbrPriority INTEGER
  fmOspfStandardNbrState INTEGER
  fmOspfStandardNbrEvents Counter
  fmOspfStandardNbrLSRetransQLen Gauge
  fmOspfStandardNBMANbrStatus INTEGER

FmOspfStandardVirtNbrEntry  
SEQUENCE    
  fmOspfStandardVirtNbrArea IpAddress
  fmOspfStandardVirtNbrRtrId IpAddress
  fmOspfStandardVirtNbrIpAddr IpAddress
  fmOspfStandardVirtNbrOptions INTEGER
  fmOspfStandardVirtNbrState INTEGER
  fmOspfStandardVirtNbrEvents Counter
  fmOspfStandardVirtNbrLSRetransQLen Gauge

FmsInArpVirtualPortEntry  
SEQUENCE    
  fmsInArpVpConnX121 OCTET STRING
  fmsInArpVpVirtualPortId INTEGER
  fmsInArpVpOutRequests Counter
  fmsInArpVpInResponses Counter
  fmsInArpVpInRequests Counter
  fmsInArpVpOutResponses Counter
  fmsInArpVpInverseArpStatus INTEGER
  fmsInArpVpRemoteIpAddr IpAddress
  fmsInArpVpLocalIpAddr IpAddress

FmsBootPRelayEntry  
SEQUENCE    
  fmsBootPRelayVirtualPortId INTEGER
  fmsBootPRelayRelayedPkts Counter
  fmsBootPRelayDroppedPkts Counter
  fmsBootPRelayRecRequests Counter
  fmsBootPRelayRecReplies Counter

FdpModResponseEntry  
SEQUENCE    
  fdpModRespEltNum INTEGER
  fdpModRespElement DisplayString

VcCtlErrorEntry  
SEQUENCE    
  vcCtlErrorIndex INTEGER
  vcCtlErrorCode INTEGER
  vcCtlErrorMessage DisplayString
  vcCtlErrorTime TimeTicks

VcmAlrmGenEntry  
SEQUENCE    
  vcmAlrmGenFamilyId INTEGER
  vcmAlrmGenTyp INTEGER
  vcmAlrmGenTrapSend INTEGER
  vcmAlrmGenDisplay INTEGER

VcmAlrmSCEntry  
SEQUENCE    
  vcmAlrmSCFamilyId INTEGER
  vcmAlrmSCTyp INTEGER
  vcmAlrmSCTrapSend INTEGER
  vcmAlrmSCDisplay INTEGER

VcmAlrmVCEntry  
SEQUENCE    
  vcmAlrmVCFamilyId INTEGER
  vcmAlrmVCTyp INTEGER
  vcmAlrmVCTrapSend INTEGER
  vcmAlrmVCDisplay INTEGER

VcmAlrmLMIEntry  
SEQUENCE    
  vcmAlrmLMIFamilyId INTEGER
  vcmAlrmLMITyp INTEGER
  vcmAlrmLMITrapSend INTEGER
  vcmAlrmLMIDisplay INTEGER

VcmAlrmSwEntry  
SEQUENCE    
  vcmAlrmSwFamilyId INTEGER
  vcmAlrmSwTyp INTEGER
  vcmAlrmSwTrapSend INTEGER
  vcmAlrmSwDisplay INTEGER

VcmAlrmCmpEntry  
SEQUENCE    
  vcmAlrmCmpFamilyId INTEGER
  vcmAlrmCmpTyp INTEGER
  vcmAlrmCmpTrapSend INTEGER
  vcmAlrmCmpDisplay INTEGER

VcmAlrmFaxEntry  
SEQUENCE    
  vcmAlrmFaxFamilyId INTEGER
  vcmAlrmFaxTyp INTEGER
  vcmAlrmFaxTrapSend INTEGER
  vcmAlrmFaxDisplay INTEGER

VcmAlrmTftpEntry  
SEQUENCE    
  vcmAlrmTftpFamilyId INTEGER
  vcmAlrmTftpTyp INTEGER
  vcmAlrmTftpTrapSend INTEGER
  vcmAlrmTftpDisplay INTEGER

VcmAlrmSvcEntry  
SEQUENCE    
  vcmAlrmSvcFamilyId INTEGER
  vcmAlrmSvcTyp INTEGER
  vcmAlrmSvcTrapSend INTEGER
  vcmAlrmSvcDisplay INTEGER

VcfPhysicalPortEntry  
SEQUENCE    
  vcfPhysPortId INTEGER
  vcfPhysPortConnector INTEGER

VcfNumericLineEntry  
SEQUENCE    
  vcfNumericLineInterfaceId INTEGER
  vcfNumericLineType INTEGER

VcfDataLineEntry  
SEQUENCE    
  vcfDataLineInterfaceId INTEGER
  vcfDataLineRate INTEGER
  vcfDataLineRts105 INTEGER
  vcfDataLineDtr108 INTEGER
  vcfDataLineCts106 INTEGER
  vcfDataLineDsr107 INTEGER
  vcfDataLineDcd109 INTEGER

VcfConfLineEntry  
SEQUENCE    
  vcfConfLineInterfaceId INTEGER
  vcfConfLineRate INTEGER

VcFrSwitchingEntry  
SEQUENCE    
  vcFrSwL0Dlci INTEGER
  vcFrSwL1Dlci INTEGER
  vcFrSwStatus INTEGER
  vcFrSwL0DlciPriority INTEGER
  vcFrSwL0MuxEnable INTEGER
  vcFrSwL0ChanelIdentifierCID INTEGER
  vcFrSwL1DlciPriority INTEGER
  vcFrSwL1MuxEnable INTEGER
  vcFrSwL1ChanelIdentifierCID INTEGER

VclLogicalPortEntry  
SEQUENCE    
  vclLogPortId INTEGER
  vclLogPortStatus INTEGER
  vclLogPortType INTEGER

VclHdlcLogPortEntry  
SEQUENCE    
  vclHdlcLpLogPortId INTEGER
  vclHdlcLpFragmentationLength INTEGER
  vclHdlcLpRemoteAddress OCTET STRING

VclFrCeLogPortEntry  
SEQUENCE    
  vclFrCeLpLogPortId INTEGER
  vclFrCeLpInterfaceId INTEGER

VclFrTeLogPortEntry  
SEQUENCE    
  vclFrTeLpLogPortId INTEGER
  vclFrTeLpInterfaceId INTEGER
  vclFrTeLpConfigId INTEGER
  vclFrTeLpLmi INTEGER

VclFrSeLogPortEntry  
SEQUENCE    
  vclFrSeLpLogPortId INTEGER
  vclFrSeLpInterfaceId INTEGER
  vclFrSeLpConfigId INTEGER

VclFrLmiParameterEntry  
SEQUENCE    
  vclFrLmiParaConfigId INTEGER
  vclFrLmiParaDlci INTEGER
  vclFrLmiParaStandard INTEGER
  vclFrLmiParaAccessibilityCondition INTEGER
  vclFrLmiParaN391FullStatusPollCount INTEGER
  vclFrLmiParaN392ErrorThreshold INTEGER
  vclFrLmiParaN393MonitoredEventCount INTEGER
  vclFrLmiParaT391LinkIntegPollTimer INTEGER

VclFrSeSignallingEntry  
SEQUENCE    
  vclFrSeSigConfigId INTEGER
  vclFrSeSigOuputTimeout INTEGER
  vclFrSeSigSignalOutputWinSize INTEGER
  vclFrSeSigN200RetransMaxCount INTEGER
  vclFrSeSigT200RetransTimer INTEGER
  vclFrSeSigT203InactivityTimer INTEGER
  vclFrSeSigT303SetupResponseTimer INTEGER
  vclFrSeSigT305DisconnectResponseTimer INTEGER
  vclFrSeSigT308ReleaseResponseTimer INTEGER
  vclFrSeSigT310CallProceedingTimer INTEGER
  vclFrSeSigT316RestartAcknowledgeTimer INTEGER

VcwABPvcLpEntry  
SEQUENCE    
  vcwABPvcLpId INTEGER
  vcwABPvcLpAddress OCTET STRING

VcwWanRouteEntry  
SEQUENCE    
  vcwWanRouteDnicZoAddress OCTET STRING
  vcwWanRouteStatus INTEGER
  vcwWanRouteLogPortId INTEGER

VcvVirtualPortEntry  
SEQUENCE    
  vcvVirtualPortId INTEGER

VcvIpLocalEntry  
SEQUENCE    
  vcvIpLocVirtualPortId INTEGER
  vcvIpLocAddressHost IpAddress
  vcvIpLocSubNetMask IpAddress
  vcvIpLocMtu INTEGER
  vcvIpLocRouteNextHop IpAddress
  vcvIpLocMinimumRecallTimer INTEGER
  vcvIpLocSvcClearCallTimer INTEGER
  vcvIpLocSvcCallRetryCount INTEGER

VcvSnmpManagerEntry  
SEQUENCE    
  vcvSnmpManagerIpAddress IpAddress
  vcvSnmpManagerStatus INTEGER
  vcvSnmpManagerName DisplayString
  vcvSnmpManagerSendTraps INTEGER
  vcvSnmpManagerTrapsUdpPort INTEGER

VcvRemoteConfEntry  
SEQUENCE    
  vcvRemoteConfName DisplayString
  vcvRemoteConfStatus INTEGER
  vcvRemoteConfWanAddress OCTET STRING

VcvTftpEntry  
SEQUENCE    
  vcvTftpIpAddress IpAddress
  vcvTftpStatus INTEGER
  vcvTftpName DisplayString
  vcvTftpRetryTimer INTEGER
  vcvTftpInactTimer INTEGER

VcvRemoteNetToMediaEntry  
SEQUENCE    
  vcvRemNetIpAddress IpAddress
  vcvRemNetStatus INTEGER
  vcvRemNetWanAddress OCTET STRING
  vcvRemNetEncapsulation INTEGER

VcvVoiceTransportEntry  
SEQUENCE    
  vcvVoiceTransProfileId INTEGER
  vcvVoiceTransEncapsulationMode INTEGER
  vcvVoiceTransMaxPayLoadNumber INTEGER
  vcvVoiceTransCompressionAlgorithm INTEGER
  vcvVoiceTransJitterCompensation INTEGER
  vcvVoiceTransVoicePacketsCombination INTEGER
  vcvVoiceTransQosBc INTEGER
  vcvVoiceTransQosBe INTEGER
  vcvVoiceTransQosCir INTEGER

VcvVoiceSuscriberEntry  
SEQUENCE    
  vcvVoiceSuscrOrderNumber INTEGER
  vcvVoiceSuscrNumber DisplayString
  vcvVoiceSuscrStatus INTEGER
  vcvVoiceSuscrTransportNetwork INTEGER
  vcvVoiceSuscrTransportNetworkAddress OCTET STRING
  vcvVoiceSuscrTransportProfileId INTEGER
  vcvVoiceSuscrRemovedDigitNumber INTEGER
  vcvVoiceSuscrInsPrefix DisplayString
  vcvVoiceSuscrInsSuffix DisplayString

VcvVoiceSwEntry  
SEQUENCE    
  vcvVoiceSwOrderNumber INTEGER
  vcvVoiceSwSuscriberNumber DisplayString
  vcvVoiceSwStatus INTEGER
  vcvVoiceSwLogPortSetId INTEGER
  vcvVoiceSwRemovedDigitNumber INTEGER
  vcvVoiceSwInsPrefix DisplayString
  vcvVoiceSwInsSuffix DisplayString

VcvDialingReceptEntry  
SEQUENCE    
  vcvDialRxSuscriberNumber DisplayString
  vcvDialRxStatus INTEGER
  vcvDialRxNumberLength INTEGER
  vcvDialRxEndOfDialingTimer INTEGER

VcvVoiceLogicalPortEntry  
SEQUENCE    
  vcvVoiceLogPortId INTEGER
  vcvVoiceLogPortStatus INTEGER
  vcvVoiceLogPortType INTEGER

VcvToneGenEntry  
SEQUENCE    
  vcvToneGenProfileId INTEGER
  vcvToneGenLevel INTEGER

VcvToneEntry  
SEQUENCE    
  vcvToneProfileId INTEGER
  vcvToneType INTEGER
  vcvToneEnable INTEGER
  vcvToneFreq1 INTEGER
  vcvToneDuration1 INTEGER
  vcvToneFreq2 INTEGER
  vcvToneDuration2 INTEGER

VcvEMPermEntry  
SEQUENCE    
  vcvEMPermLpId INTEGER
  vcvEMPermCommunicationMode INTEGER
  vcvEMPermRemoteNumber DisplayString
  vcvEMPermInterfaceId INTEGER

VcvEMSwEntry  
SEQUENCE    
  vcvEMSwLpId INTEGER
  vcvEMSwLogPortSetId INTEGER
  vcvEMSwCallType INTEGER
  vcvEMSwRemoteNumber DisplayString
  vcvEMSwConfigId INTEGER
  vcvEMSwInterfaceId INTEGER

VcvEMConfigEntry  
SEQUENCE    
  vcvEMConfId INTEGER
  vcvEMConfCallSignalling INTEGER
  vcvEMConfDialingMode INTEGER
  vcvEMConfDialingTimeOut INTEGER
  vcvEMConfSigChannelDiscTimeOut INTEGER
  vcvEMConfTimeBetweenSuccOutCall INTEGER
  vcvEMConfLineInterfacePolarity INTEGER
  vcvEMConfMinLineSeizureAckTime INTEGER
  vcvEMConfMaxLineSeizureAckTime INTEGER
  vcvEMConfLineSeizureAckTime INTEGER
  vcvEMConfClearToIncCallTime INTEGER
  vcvEMConfSeizureAckPulseDuration INTEGER
  vcvEMConfMinSeizureAckPulseDuration INTEGER
  vcvEMConfDialingFormat INTEGER
  vcvEMConfInterdigitTime INTEGER
  vcvEMConfPauseTime INTEGER
  vcvEMConfDtmfDigitTime INTEGER
  vcvEMConfDtmfDigitLevel INTEGER
  vcvEMConfDelayBeforeDialing INTEGER
  vcvEMConfDigitReceptionTimeOut INTEGER
  vcvEMConfEndOfDialingTimer INTEGER
  vcvEMConfToneProfile INTEGER

VcvFxxLpEntry  
SEQUENCE    
  vcvFxxLpLogPortId INTEGER
  vcvFxxLpSetId INTEGER
  vcvFxxLpCallType INTEGER
  vcvFxxLpRemoteNumber DisplayString
  vcvFxxLpConfigId INTEGER
  vcvFxxLpInterfaceId INTEGER

VcvFxxConfigEntry  
SEQUENCE    
  vcvFxxConfId INTEGER
  vcvFxxConfCallSignalling INTEGER
  vcvFxxConfDialingMode INTEGER
  vcvFxxConfSigChannelDiscTimeOut INTEGER
  vcvFxxConfTimeBetweenSuccOutCall INTEGER
  vcvFxxConfDialingFormat INTEGER
  vcvFxxConfInterdigitTime INTEGER
  vcvFxxConfPauseTime INTEGER
  vcvFxxConfDtmfDigitTime INTEGER
  vcvFxxConfDtmfDigitLevel INTEGER
  vcvFxxConfTxRecallSignalDuration INTEGER
  vcvFxxConfDelayBeforeDialing INTEGER
  vcvFxxConfDialingTimeOut INTEGER
  vcvFxxConfDigitReceptionTimeOut INTEGER
  vcvFxxConfEndOfDialingTimer INTEGER
  vcvFxxConfMinRxRecallSignalDuration INTEGER
  vcvFxxConfToneProfile INTEGER
  vcvFxxConfRingingProfile INTEGER

VcvFxxRingEntry  
SEQUENCE    
  vcvFxxRingProfile INTEGER
  vcvFxxRingFrequency INTEGER
  vcvFxxRingTopDuration INTEGER
  vcvFxxRingSilenceDuration INTEGER
  vcvFxxRingMaxRingingTime INTEGER

VcvAnalogLineEntry  
SEQUENCE    
  vcvAnalogLineInterfaceId INTEGER
  vcvAnalogLineTypeInterface INTEGER
  vcvAnalogLineVoiceProfile INTEGER

VcvVoiceProfileEntry  
SEQUENCE    
  vcvVoiceProfId INTEGER
  vcvVoiceProfTransmitLevel INTEGER
  vcvVoiceProfReceiveLevel INTEGER
  vcvVoiceProfSilenceDetection INTEGER
  vcvVoiceProfSilenceDetectionLevel INTEGER
  vcvVoiceProfEchoCancellation INTEGER
  vcvVoiceProfEchoCancellationLength INTEGER
  vcvVoiceProfNoiseFramesPeriodicity INTEGER
  vcvVoiceProfLoopActivation INTEGER
  vcvVoiceProfFaxActivation INTEGER
  vcvVoiceProfMaximumFaxSpeed INTEGER

VcvVoicePhysicalPortEntry  
SEQUENCE    
  vcvVoicePhysPortId INTEGER
  vcvVoicePhysPortConnector INTEGER

DcCtlErrorEntry  
SEQUENCE    
  dcCtlErrorIndex INTEGER
  dcCtlErrorCode INTEGER
  dcCtlErrorMessage DisplayString
  dcCtlErrorTime TimeTicks

DcmAlrmGenEntry  
SEQUENCE    
  dcmAlrmGenFamilyId INTEGER
  dcmAlrmGenTyp INTEGER
  dcmAlrmGenTrapSend INTEGER
  dcmAlrmGenDisplay INTEGER

DcmAlrmSCEntry  
SEQUENCE    
  dcmAlrmSCFamilyId INTEGER
  dcmAlrmSCTyp INTEGER
  dcmAlrmSCTrapSend INTEGER
  dcmAlrmSCDisplay INTEGER

DcmAlrmVCEntry  
SEQUENCE    
  dcmAlrmVCFamilyId INTEGER
  dcmAlrmVCTyp INTEGER
  dcmAlrmVCTrapSend INTEGER
  dcmAlrmVCDisplay INTEGER

DcmAlrmLMIEntry  
SEQUENCE    
  dcmAlrmLMIFamilyId INTEGER
  dcmAlrmLMITyp INTEGER
  dcmAlrmLMITrapSend INTEGER
  dcmAlrmLMIDisplay INTEGER

DcmAlrmSwEntry  
SEQUENCE    
  dcmAlrmSwFamilyId INTEGER
  dcmAlrmSwTyp INTEGER
  dcmAlrmSwTrapSend INTEGER
  dcmAlrmSwDisplay INTEGER

DcmAlrmCmpEntry  
SEQUENCE    
  dcmAlrmCmpFamilyId INTEGER
  dcmAlrmCmpTyp INTEGER
  dcmAlrmCmpTrapSend INTEGER
  dcmAlrmCmpDisplay INTEGER

DcmAlrmFaxEntry  
SEQUENCE    
  dcmAlrmFaxFamilyId INTEGER
  dcmAlrmFaxTyp INTEGER
  dcmAlrmFaxTrapSend INTEGER
  dcmAlrmFaxDisplay INTEGER

DcmAlrmTftpEntry  
SEQUENCE    
  dcmAlrmTftpFamilyId INTEGER
  dcmAlrmTftpTyp INTEGER
  dcmAlrmTftpTrapSend INTEGER
  dcmAlrmTftpDisplay INTEGER

DcmAlrmSvcEntry  
SEQUENCE    
  dcmAlrmSvcFamilyId INTEGER
  dcmAlrmSvcTyp INTEGER
  dcmAlrmSvcTrapSend INTEGER
  dcmAlrmSvcDisplay INTEGER

DcmAlrmSyncEntry  
SEQUENCE    
  dcmAlrmSyncFamilyId INTEGER
  dcmAlrmSyncTyp INTEGER
  dcmAlrmSyncTrapSend INTEGER
  dcmAlrmSyncDisplay INTEGER

DcfPhysicalPortEntry  
SEQUENCE    
  dcfPhysPortId INTEGER
  dcfPhysPortConnector INTEGER

DcfNumericLineEntry  
SEQUENCE    
  dcfNumericLineInterfaceId INTEGER
  dcfNumericLineType INTEGER

DcfDataLineEntry  
SEQUENCE    
  dcfDataLineInterfaceId INTEGER
  dcfDataLineRate INTEGER
  dcfDataLineRts105 INTEGER
  dcfDataLineDtr108 INTEGER
  dcfDataLineCts106 INTEGER
  dcfDataLineDsr107 INTEGER
  dcfDataLineDcd109 INTEGER

DcfConfLineEntry  
SEQUENCE    
  dcfConfLineInterfaceId INTEGER
  dcfConfLineRate INTEGER

DclLogicalPortEntry  
SEQUENCE    
  dclLogPortId INTEGER
  dclLogPortStatus INTEGER
  dclLogPortType INTEGER

DclFrTeLogPortEntry  
SEQUENCE    
  dclFrTeLpLogPortId INTEGER
  dclFrTeLpInterfaceId INTEGER
  dclFrTeLpConfigId INTEGER
  dclFrTeLpLmi INTEGER

DclFrSeLogPortEntry  
SEQUENCE    
  dclFrSeLpLogPortId INTEGER
  dclFrSeLpInterfaceId INTEGER
  dclFrSeLpConfigId INTEGER

DclFrLmiParameterEntry  
SEQUENCE    
  dclFrLmiParaConfigId INTEGER
  dclFrLmiParaDlci INTEGER
  dclFrLmiParaStandard INTEGER
  dclFrLmiParaAccessibilityCondition INTEGER
  dclFrLmiParaN391FullStatusPollCount INTEGER
  dclFrLmiParaN392ErrorThreshold INTEGER
  dclFrLmiParaN393MonitoredEventCount INTEGER
  dclFrLmiParaT391LinkIntegPollTimer INTEGER

DclFrSeSignallingEntry  
SEQUENCE    
  dclFrSeSigConfigId INTEGER
  dclFrSeSigOuputTimeout INTEGER
  dclFrSeSigSignalOutputWinSize INTEGER
  dclFrSeSigN200RetransMaxCount INTEGER
  dclFrSeSigT200RetransTimer INTEGER
  dclFrSeSigT203InactivityTimer INTEGER
  dclFrSeSigT303SetupResponseTimer INTEGER
  dclFrSeSigT305DisconnectResponseTimer INTEGER
  dclFrSeSigT308ReleaseResponseTimer INTEGER
  dclFrSeSigT310CallProceedingTimer INTEGER
  dclFrSeSigT316RestartAcknowledgeTimer INTEGER

DcwABPvcLpEntry  
SEQUENCE    
  dcwABPvcLpId INTEGER
  dcwABPvcLpAddress OCTET STRING

DcvVirtualPortEntry  
SEQUENCE    
  dcvVirtualPortId INTEGER

DcvIpLocalEntry  
SEQUENCE    
  dcvIpLocVirtualPortId INTEGER
  dcvIpLocAddressHost IpAddress
  dcvIpLocSubNetMask IpAddress
  dcvIpLocMtu INTEGER
  dcvIpLocRouteNextHop IpAddress
  dcvIpLocMinimumRecallTimer INTEGER
  dcvIpLocSvcClearCallTimer INTEGER
  dcvIpLocSvcCallRetryCount INTEGER

DcvSnmpManagerEntry  
SEQUENCE    
  dcvSnmpManagerIpAddress IpAddress
  dcvSnmpManagerStatus INTEGER
  dcvSnmpManagerName DisplayString
  dcvSnmpManagerSendTraps INTEGER
  dcvSnmpManagerTrapsUdpPort INTEGER

DcvRemoteConfEntry  
SEQUENCE    
  dcvRemoteConfName DisplayString
  dcvRemoteConfStatus INTEGER
  dcvRemoteConfWanAddress OCTET STRING

DcvTftpEntry  
SEQUENCE    
  dcvTftpIpAddress IpAddress
  dcvTftpStatus INTEGER
  dcvTftpName DisplayString
  dcvTftpRetryTimer INTEGER
  dcvTftpInactTimer INTEGER

DcvRemoteNetToMediaEntry  
SEQUENCE    
  dcvRemNetIpAddress IpAddress
  dcvRemNetStatus INTEGER
  dcvRemNetWanAddress OCTET STRING
  dcvRemNetEncapsulation INTEGER

DcvVoiceTransportEntry  
SEQUENCE    
  dcvVoiceTransProfileId INTEGER
  dcvVoiceTransEncapsulationMode INTEGER
  dcvVoiceTransMaxPayLoadNumber INTEGER
  dcvVoiceTransCompressionAlgorithm INTEGER
  dcvVoiceTransJitterCompensation INTEGER
  dcvVoiceTransVoicePacketsCombination INTEGER
  dcvVoiceTransQosBc INTEGER
  dcvVoiceTransQosBe INTEGER
  dcvVoiceTransQosCir INTEGER

DcvVoiceSuscriberEntry  
SEQUENCE    
  dcvVoiceSuscrOrderNumber INTEGER
  dcvVoiceSuscrNumber DisplayString
  dcvVoiceSuscrStatus INTEGER
  dcvVoiceSuscrTransportNetwork INTEGER
  dcvVoiceSuscrTransportNetworkAddress OCTET STRING
  dcvVoiceSuscrTransportProfileId INTEGER
  dcvVoiceSuscrRemovedDigitNumber INTEGER
  dcvVoiceSuscrInsPrefix DisplayString
  dcvVoiceSuscrInsSuffix DisplayString

DcvVoiceSwEntry  
SEQUENCE    
  dcvVoiceSwOrderNumber INTEGER
  dcvVoiceSwSuscriberNumber DisplayString
  dcvVoiceSwStatus INTEGER
  dcvVoiceSwLogPortSetId INTEGER
  dcvVoiceSwRemovedDigitNumber INTEGER
  dcvVoiceSwInsPrefix DisplayString
  dcvVoiceSwInsSuffix DisplayString

DcvDialingReceptEntry  
SEQUENCE    
  dcvDialRxSuscriberNumber DisplayString
  dcvDialRxStatus INTEGER
  dcvDialRxNumberLength INTEGER
  dcvDialRxEndOfDialingTimer INTEGER

DcvVoiceLogicalPortEntry  
SEQUENCE    
  dcvVoiceLogPortId INTEGER
  dcvVoiceLogPortStatus INTEGER
  dcvVoiceLogPortType INTEGER

DcvToneGenEntry  
SEQUENCE    
  dcvToneGenProfileId INTEGER
  dcvToneGenLevel INTEGER

DcvToneEntry  
SEQUENCE    
  dcvToneProfileId INTEGER
  dcvToneType INTEGER
  dcvToneEnable INTEGER
  dcvToneFreq1 INTEGER
  dcvToneDuration1 INTEGER
  dcvToneFreq2 INTEGER
  dcvToneDuration2 INTEGER

DcvTSPCMPermEntry  
SEQUENCE    
  dcvTSPCMPermLpId INTEGER
  dcvTSPCMPermCommunicationMode INTEGER
  dcvTSPCMPermRemoteNumber DisplayString
  dcvTSPCMPermConfigId INTEGER
  dcvTSPCMPermChannIfId INTEGER

DcvTSPCMSwEntry  
SEQUENCE    
  dcvTSPCMSwLpId INTEGER
  dcvTSPCMSwLogPortSetId INTEGER
  dcvTSPCMSwCallType INTEGER
  dcvTSPCMSwRemoteNumber DisplayString
  dcvTSPCMSwConfigId INTEGER
  dcvTSPCMSwChannIfId INTEGER

DcvCASConfigEntry  
SEQUENCE    
  dcvCASConfId INTEGER
  dcvCASConfSignallingTransport INTEGER
  dcvCASConfCallSignalling INTEGER
  dcvCASConfDialingMode INTEGER
  dcvCASConfDialingTimeOut INTEGER
  dcvCASConfSigChannelDiscTimeOut INTEGER
  dcvCASConfTimeBetweenSuccOutCall INTEGER
  dcvCASConfLineInterfacePolarity INTEGER
  dcvCASConfMinLineSeizureAckTime INTEGER
  dcvCASConfMaxLineSeizureAckTime INTEGER
  dcvCASConfLineSeizureAckTime INTEGER
  dcvCASConfClearToIncCallTime INTEGER
  dcvCASConfSeizureAckPulseDuration INTEGER
  dcvCASConfMinSeizureAckPulseDuration INTEGER
  dcvCASConfDialingFormat INTEGER
  dcvCASConfInterdigitTime INTEGER
  dcvCASConfPauseTime INTEGER
  dcvCASConfDtmfDigitTime INTEGER
  dcvCASConfDtmfDigitLevel INTEGER
  dcvCASConfDelayBeforeDialing INTEGER
  dcvCASConfDigitReceptionTimeOut INTEGER
  dcvCASConfEndOfDialingTimer INTEGER
  dcvCASConfToneProfile INTEGER
  dcvCASConfIdleState INTEGER
  dcvCASConfAlarmState INTEGER

DcvIfPCMPhysEntry  
SEQUENCE    
  dcvIfPCMPhysIfId INTEGER
  dcvIfPCMPhysTypeId INTEGER
  dcvIfPCMPhysPhysicalPort INTEGER

DcvIfPCMChannelEntry  
SEQUENCE    
  dcvIfPCMChannelIfId INTEGER
  dcvIfPCMChannelStatus INTEGER
  dcvIfPCMChannelVoiceProfId INTEGER
  dcvIfPCMChannelPhysIf INTEGER

DcvVoiceProfileEntry  
SEQUENCE    
  dcvVoiceProfId INTEGER
  dcvVoiceProfTransmitLevel INTEGER
  dcvVoiceProfReceiveLevel INTEGER
  dcvVoiceProfSilenceDetection INTEGER
  dcvVoiceProfSilenceDetectionLevel INTEGER
  dcvVoiceProfEchoCancellation INTEGER
  dcvVoiceProfEchoCancellationLength INTEGER
  dcvVoiceProfNoiseFramesPeriodicity INTEGER
  dcvVoiceProfLoopActivation INTEGER
  dcvVoiceProfFaxActivation INTEGER
  dcvVoiceProfMaximumFaxSpeed INTEGER
  dcvVoiceProfCESMode INTEGER
  dcvVoiceProfCESModeAverageDelay INTEGER

DcvVoicePhysicalPortEntry  
SEQUENCE    
  dcvVoicePhysPortId INTEGER
  dcvVoicePhysPortConnector INTEGER

Defined Values

pce 2.1.866
OBJECT IDENTIFIER    

products 2.1.866.1
OBJECT IDENTIFIER    

manager 2.1.866.2
OBJECT IDENTIFIER    

systemDescription 2.1.866.3
OBJECT IDENTIFIER    

projects 2.1.866.4
OBJECT IDENTIFIER    

frxSoftware 2.1.866.20
OBJECT IDENTIFIER    

frxConfig 2.1.866.20.1
OBJECT IDENTIFIER    

frxManagement 2.1.866.20.10
OBJECT IDENTIFIER    

frxDiagnostic 2.1.866.20.20
OBJECT IDENTIFIER    

vcxSoftware 2.1.866.30
OBJECT IDENTIFIER    

vcxConfig 2.1.866.30.1
OBJECT IDENTIFIER    

dvbConfig 2.1.866.30.20
OBJECT IDENTIFIER    

mmxSoftware 2.1.866.40
OBJECT IDENTIFIER    

compacProxySoftware 2.1.866.51
OBJECT IDENTIFIER    

compacV9toV11 2.1.866.1.1
OBJECT IDENTIFIER    

transProduct 2.1.866.1.10
OBJECT IDENTIFIER    

netAccessProduct 2.1.866.1.20
OBJECT IDENTIFIER    

adaptis 2.1.866.1.20.10
OBJECT IDENTIFIER    

vpx10 2.1.866.1.20.20
OBJECT IDENTIFIER    

vpx20 2.1.866.1.20.21
OBJECT IDENTIFIER    

mcx103 2.1.866.1.20.30
OBJECT IDENTIFIER    

mcx104 2.1.866.1.20.31
OBJECT IDENTIFIER    

atLan 2.1.866.1.20.40
OBJECT IDENTIFIER    

mcx300 2.1.866.1.20.50
OBJECT IDENTIFIER    

frx300 2.1.866.1.20.60
OBJECT IDENTIFIER    

vcx100 2.1.866.1.20.90
OBJECT IDENTIFIER    

avb1002-EM 2.1.866.1.20.200
OBJECT IDENTIFIER    

avb1002-FXS-FXO 2.1.866.1.20.201
OBJECT IDENTIFIER    

sc103-3W 2.1.866.1.20.210
OBJECT IDENTIFIER    

sc103-6W 2.1.866.1.20.211
OBJECT IDENTIFIER    

sc103-6W-M 2.1.866.1.20.212
OBJECT IDENTIFIER    

sc104 2.1.866.1.20.220
OBJECT IDENTIFIER    

sc106 2.1.866.1.20.225
OBJECT IDENTIFIER    

sc112 2.1.866.1.20.226
OBJECT IDENTIFIER    

sc300-1W-1E 2.1.866.1.20.230
OBJECT IDENTIFIER    

sc300-3W-1E 2.1.866.1.20.231
OBJECT IDENTIFIER    

sc300-4W 2.1.866.1.20.232
OBJECT IDENTIFIER    

sc310-8W 2.1.866.1.20.240
OBJECT IDENTIFIER    

sc310-12W 2.1.866.1.20.241
OBJECT IDENTIFIER    

sc320-4W-1TR 2.1.866.1.20.250
OBJECT IDENTIFIER    

sc320-8W-1TR 2.1.866.1.20.251
OBJECT IDENTIFIER    

sc330 2.1.866.1.20.254
OBJECT IDENTIFIER    

sc1200 2.1.866.1.20.255
OBJECT IDENTIFIER    

netConcentratorProduct 2.1.866.1.30
OBJECT IDENTIFIER    

mcx09 2.1.866.1.30.20
OBJECT IDENTIFIER    

mcx109 2.1.866.1.30.21
OBJECT IDENTIFIER    

mcx106 2.1.866.1.30.30
OBJECT IDENTIFIER    

mcx112 2.1.866.1.30.35
OBJECT IDENTIFIER    

mcx212 2.1.866.1.30.40
OBJECT IDENTIFIER    

mcx212Y 2.1.866.1.30.41
OBJECT IDENTIFIER    

mcx512 2.1.866.1.30.45
OBJECT IDENTIFIER    

mcx512Y 2.1.866.1.30.46
OBJECT IDENTIFIER    

lmx506 2.1.866.1.30.50
OBJECT IDENTIFIER    

frx800 2.1.866.1.30.60
OBJECT IDENTIFIER    

sc512 2.1.866.1.30.210
OBJECT IDENTIFIER    

sc512Y 2.1.866.1.30.211
OBJECT IDENTIFIER    

hpb1025-8W 2.1.866.1.30.220
OBJECT IDENTIFIER    

hpb1025-12W 2.1.866.1.30.221
OBJECT IDENTIFIER    

spb1033 2.1.866.1.30.250
OBJECT IDENTIFIER    

dvb1008 2.1.866.1.30.270
OBJECT IDENTIFIER    

netBackboneProduct 2.1.866.1.40
OBJECT IDENTIFIER    

npx09 2.1.866.1.40.20
OBJECT IDENTIFIER    

npx90 2.1.866.1.40.21
OBJECT IDENTIFIER    

frx1000 2.1.866.1.40.60
OBJECT IDENTIFIER    

frx2000 2.1.866.1.40.65
OBJECT IDENTIFIER    

frx2000Y 2.1.866.1.40.70
OBJECT IDENTIFIER    

mmx5000 2.1.866.1.40.100
OBJECT IDENTIFIER    

mmx10000 2.1.866.1.40.105
OBJECT IDENTIFIER    

sc5000 2.1.866.1.40.200
OBJECT IDENTIFIER    

netCentralSiteProduct 2.1.866.1.50
OBJECT IDENTIFIER    

fpb2025 2.1.866.1.50.200
OBJECT IDENTIFIER    

rpb2025 2.1.866.1.50.201
OBJECT IDENTIFIER    

spb2033 2.1.866.1.50.250
OBJECT IDENTIFIER    

dvb2030 2.1.866.1.50.270
OBJECT IDENTIFIER    

nodeName 2.1.866.2.1
This describes the name of the node whose status has changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

nodeStatus 2.1.866.2.2
This describes the status of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notMonitored(8), inService(1), serviceInterrupted(2), unknown(3), crippled(4), functionOccupied(6), callForBackupAddress(7)  

portLabel 2.1.866.2.3
This describes the label of the port whose status has changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

portNumber 2.1.866.2.4
This describes the number of the port whose status has changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portStatus 2.1.866.2.5
This describes the status of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notMonitored(8), inService(1), serviceInterrupted(2), unknown(3), shiftToPstn(5)  

changeDescription 2.1.866.2.6
Description of the status report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

nodeStatusChanged 0
Tok_String
TRAP-TYPE    

lineStatusChanged 1
Tok_String
TRAP-TYPE    

fcControl 2.1.866.20.1.1
OBJECT IDENTIFIER    

fcCtlConfigurationState 2.1.866.20.1.1.1
The value of this object indicates the current state of the configuration (see fcCtlConfigurationCommand to manage this configuration) : noChange : not any objects has been modified since the last 'load' command or the last boot, notReady : this configuration can not be saved because it has not been checked or it has been checked but it contains some errors, limitedReset : this configuration may be saved and it may be taken into account by a 'hotReset' command, reboot : this configuration may be saved and it will be taken into account by the next 'reboot' command (the 'hotReset' command is not enough complete), savingInProgress : this configuration is beeing saved, do not modify any parameter while this saving is being processed, loadingInProgress : a new configuration is beeing loaded, do not modify any parameter while this loading is being processed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noChange(1), notReady(2), limitedReset(10), reboot(11), savingInProgress(20), loadingInProgress(21)  

fcCtlStateCheckingResults 2.1.866.20.1.1.2
The value of this object indicates the results of the checking controls of the configuration. This message is also recorded in fcCtlErrorTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

fcCtlConfigurationCommand 2.1.866.20.1.1.10
The value of this object is the command used to manage the current configuration : ready : this value is always returned by the equipment in response to a GET request, check : a SET to this value starts the global checking of the current configuration (the possible errors are described in fcCtlStateCheckingResults), determines which ports are concerned by the modifications (see fcCtlAlteredLpTable and fcCtlAlteredIfTable for the list of these ports) and sets fcCtlConfigurationState to 'notReady', 'limitedReset' or 'reboot', load : a SET to this value starts the loading of the configuration from fcCtlStorageDevice, this configuration replaces the current one (do not modify any parameter while this loading is being processed), save : a SET to this value starts the saving of the current configuration to fcCtlStorageDevice (do not modify any parameter while this saving is being processed). This saving procedure must follow a checking command with correct results. erase : not available, hotReset : a SET to this value resets (i.e., disconnects and connects) the ports, the parameters of which have been changed (see fcCtlAlteredLpTable and fcCtlAlteredIfTable for the list of these ports), this is possible only if fcCtlConfigurationState is equal to 'limitedReset', reboot : a SET to this value reboots the equipment, the configuration taken into account is specified by fcCtlBootDevice. When the current configuration is going to be modified, it is advisable to save a valid one on the backupNvram to avoid the loss of accessibility to the equipment. The default value is 'ready'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), check(2), load(5), save(6), erase(7), hotReset(10), reboot(20)  

fcCtlBootDevice 2.1.866.20.1.1.20
The value of this object is the device containing the configuration which will be used by the equipment at next boot time. When the equipment fails to boot because of an inconsistent configuration, it will retry to boot with another one as following : normalNvram : normal non volatile random access memory (i.e., first part of the EEPROM), when it boots the equipment tries to use the configuration from : 1st time : normalNvram, 2nd time normalNvram, 3rd time backupNvram, 4th time flashMemory. backupNvram : backup non volatile random access memory (i.e., second part of the EEPROM), when it boots the equipment tries to use the configuration from : 1st time backupNvram, 2nd time backupNvram, 3rd time flashMemory. startCard : start card, when it boots the equipment tries to use the configuration from : 1st time startCard, 2nd time startCard, 3rd time backupNvram, 4th time flashMemory. The default value is 'normalNvram'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normalNvram(1), backupNvram(2), startCard(3)  

fcCtlStorageDevice 2.1.866.20.1.1.21
The value of this object is the device where the next load or save command will operate : normalNvram : normal non volatile random access memory (i.e., first part of the EEPROM), backupNvram : backup non volatile random access memory (i.e., second part of the EEPROM), startCard : start card, flashMemory : flash memory, this device is not available for the save command (this configuration is a minimum one). The default value is 'normalNvram'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normalNvram(1), backupNvram(2), startCard(3), flashMemory(4)  

fcCtlAlteredLpTable 2.1.866.20.1.1.30
This table contains the logical ports that will be reinitialized by the next hotReset command.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcCtlAlteredLpEntry

fcCtlAlteredLpEntry 2.1.866.20.1.1.30.1
An entry of fcCtlAlteredLpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcCtlAlteredLpEntry  

fcCtlAlteredLpId 2.1.866.20.1.1.30.1.1
The value of this object identifies one and only one logical port which will be reinitialized by the next hotReset command (see fcCtlConfigurationCommand).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fcCtlAlteredDlciTable 2.1.866.20.1.1.31
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcCtlAlteredDlciEntry

fcCtlAlteredDlciEntry 2.1.866.20.1.1.31.1
An entry of fcCtlAlteredDlciTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcCtlAlteredDlciEntry  

fcCtlAlteredDlciPpId 2.1.866.20.1.1.31.1.1
PP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fcCtlAlteredDlciNum 2.1.866.20.1.1.31.1.2
DLCI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

fcCtlAlteredDlciState 2.1.866.20.1.1.31.1.3
Etat
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER added(1), notchanged(2), modified(3), suppressed(4)  

fcCtlAlteredIfTable 2.1.866.20.1.1.32
This table contains the interfaces that will be reinitialized by the next hotReset command.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcCtlAlteredIfEntry

fcCtlAlteredIfEntry 2.1.866.20.1.1.32.1
An entry of fcCtlAlteredIfTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcCtlAlteredIfEntry  

fcCtlAlteredIfId 2.1.866.20.1.1.32.1.1
The value of this object identifies one and only one interface which will be reinitialized by the next hotReset command (see fcCtlConfigurationCommand).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fcCtlErrorTable 2.1.866.20.1.1.40
This table contains the last 8 configuration messages. The last message is the first one in the table (fcCtlErrorIndex = 1), the oldest is the last one (fcCtlErrorIndex = 8).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcCtlErrorEntry

fcCtlErrorEntry 2.1.866.20.1.1.40.1
An entry of fcCtlErrorTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcCtlErrorEntry  

fcCtlErrorIndex 2.1.866.20.1.1.40.1.1
The value of this object identifies one and only one message. '1' identifies the last message and '8' the oldest one.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

fcCtlErrorCode 2.1.866.20.1.1.40.1.2
The value of this object is the error code for this error. '0' means that this message does not contain an error but some useful informations.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fcCtlErrorMessage 2.1.866.20.1.1.40.1.3
The value of this object is the textual description of this message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

fcCtlErrorTime 2.1.866.20.1.1.40.1.4
The value of this object is the value of sysUpTime when this message was recorded.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fcCtlHRCheckMessagesTable 2.1.866.20.1.1.50
This table contains .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcCtlHRCheckMessagesEntry

fcCtlHRCheckMessagesEntry 2.1.866.20.1.1.50.1
An entry of fcCtlHRCheckMessagesTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcCtlHRCheckMessagesEntry  

fcCtlHRCheckMsgIndex 2.1.866.20.1.1.50.1.1
The value of this object identifies one and only one message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

fcCtlHRCheckMsgCode 2.1.866.20.1.1.50.1.2
The value of this object is .
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcCtlHRCheckMessage 2.1.866.20.1.1.50.1.3
The value of this object is .
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

fcSystem 2.1.866.20.1.2
OBJECT IDENTIFIER    

fcsConfigDescription 2.1.866.20.1.2.1
OBJECT IDENTIFIER    

fcsConfigDescName 2.1.866.20.1.2.1.1
The value of this object is a textual comment. It can be used to store a little description of the configuration or of the equipment. This is a 0 to 8 ASCII characters string. The default value is 'Default'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

fcsConfigDescAuthor 2.1.866.20.1.2.1.2
The value of this object is a textual comment. It can be used to store the name of the person who creates the configuration. This is a 0 to 8 ASCII characters string. The default value is 'PCE'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

fcsConfigDescDate 2.1.866.20.1.2.1.3
The value of this object is an octet string comment. It can be used to store the date when the configuration is created. This is a three-bytes octet string with digits in the range 0 to 9. The default value is '01 01 96'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

fcsConfigDescVersion 2.1.866.20.1.2.1.4
The value of this object can be used to store the version of the configuration. This is a decimal integer in the range 1 to 254. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fcsHardwareDescription 2.1.866.20.1.2.2
OBJECT IDENTIFIER    

fcsHardDescReplicatedMode 2.1.866.20.1.2.2.1
The value of this object indicates whether the replicated mode is enabled (on two or three modules) or not. The replicated mode permits, inside a unit with two or three modules, to backup all the lines of a breakdown module on the remaining ones. This feature can be enabled only on a particular hardware. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onTwoModules(3), onThreeModules(4)  

fcsModuleTable 2.1.866.20.1.2.5
This table defines for each module of the subscriber number of the bridge and routers entities, and which of these entities must be initialized (i.e., must reserve resources). It is not possible to add or delete an entry of this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcsModuleEntry

fcsModuleEntry 2.1.866.20.1.2.5.1
An entry of fcsModuleTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcsModuleEntry  

fcsModuleId 2.1.866.20.1.2.5.1.1
The value of this object identifies one and only one module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2  

fcsModuleSubscriberNumber 2.1.866.20.1.2.5.1.2
The value of this object is the subscriber number added to the DNICZO of the equipment to make the calling address in a call sent from the bridge or routers entities of this module. This is a one-byte octet string with 2 digits in the range 0 to 9. The default values are '93' for the module 0, '94' for the module 1, '95' for the module 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcsModuleBridgeInit 2.1.866.20.1.2.5.1.5
The value of this object indicates whether the bridge entity is initialized on this module or not. When not initialized this entity does not reserve resources that thus are available for other entities. The default value is 'off' for each of the three modules.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcsModuleIpxRouterInit 2.1.866.20.1.2.5.1.6
The value of this object indicates whether the IPX router entity is initialized on this module or not. When not initialized this entity does not reserve resources that thus are available for other entities. The default value is 'off' for each of the three modules.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcsModuleClnpRouterInit 2.1.866.20.1.2.5.1.7
The value of this object indicates whether the CLNP router entity is initialized on this module or not. When not initialized this entity does not reserve resources that thus are available for other entities. The default value is 'off' for each of the three modules.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcManagement 2.1.866.20.1.3
OBJECT IDENTIFIER    

fcmManagementFunctions 2.1.866.20.1.3.1
OBJECT IDENTIFIER    

fcmMgtFctActivationTable 2.1.866.20.1.3.1.1
This table indicates the activation of each management function. It is not possible to add or delete an entry of this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcmMgtFctActivationEntry

fcmMgtFctActivationEntry 2.1.866.20.1.3.1.1.1
An entry of fcmMgtFctActivationTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcmMgtFctActivationEntry  

fcmMgfActName 2.1.866.20.1.3.1.1.1.1
The value of this object identifies oneand only one management function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER trafficGeneration(1), observation(2), statistics(3), outstandingEvents(4), fileTransfer(5), telemaintenance(6), alarm(8), userInterface(10), billing(11), extendedStatistics(12), exploitationAccess(17)  

fcmMgfActAdminStatus 2.1.866.20.1.3.1.1.1.2
The value of this object indicates whether this management function is initialized or not. When not initialized this management function does not reserve resources that thus are available for other entities. The default values are : trafficGeneration : on, observation : on, statistics : on, outstandingEvents : on, fileTransfer : on, telemaintenance : on, alarm : off, userInterface : on, billing : on, extendedStatistics : off, exploitationAccess : on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcmMgfActPassword 2.1.866.20.1.3.1.1.1.3
The value of this object is the password needed to enable this management function. This password takes place in the call user data of a call to this management function. It must contains 1 to 6 alphanumeric characters (except for 'alarm' which can not be called and then does not use a password). The default values are : trafficGeneration : GG, observation : OO, statistics : SS, outstandingEvents : EE, fileTransfer : TT, telemaintenance : MM, alarm : (empty), userInterface : RR, billing : TX, extendedStatistics : SC, exploitationAccess : PP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..6)  

fcmMgtFctParameters 2.1.866.20.1.3.1.2
OBJECT IDENTIFIER    

fcmMgfGeneratorCount 2.1.866.20.1.3.1.2.1
The value of this object is the maximum number of traffic generators that may be enabled. This is a decimal integer in the range 1 to 15. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fcmMgfGeneratorsAction 2.1.866.20.1.3.1.2.2
The value of this object indicates whether the generators send traffic ('output') or receive traffic ('input'). The default value is 'output'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER output(1), input(2)  

fcmMgfGeneratorsDelay 2.1.866.20.1.3.1.2.3
The value of this object indicates, when the generators send traffic, the delay in seconds between two successive sent packets. This is a decimal integer in the range 0 to 98. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..98  

fcmMgfAlarmsSubscriber1 2.1.866.20.1.3.1.2.10
The value of this object indicates the X121 address of the main manager to which the alarms will be sent. This is a eight-bytes octet string with up to 15 digits in the range 0 to 9. It must be padded with 'F' digits for a total of 16 digits. The equipment configurator does not need this final padding. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcmMgfAlarmsSubscriber2 2.1.866.20.1.3.1.2.11
The value of this object indicates the X121 address of the backup manager to which the alarms will be sent. This is a eight-bytes octet string with up to 15 digits in the range 0 to 9. It must be padded with 'F' digits for a total of 16 digits. The equipment configurator does not need this final padding. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcmMgfStatSummingPeriod 2.1.866.20.1.3.1.2.20
The value of this object indicates the period, in seconds, during which the statistics are calculated in the 'notInfinite' summing mode (see fmsCtrlSumming). This is a decimal integer in the range 10 to 990 by step of 10. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..990  

fcmMgfStatBufferThreshold 2.1.866.20.1.3.1.2.21
The value of this object indicates a threshold in percents used by the statistics management function. The statistics management function calculates how long more than fcmMgfStatBufferThreshold percents of buffers are used and how long more than fcmMgfStatBufferThreshold percents of CPU is busy. This is a decimal integer in the range 0 to 100. The default value is '75'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fcmMgfStatThroughputSamplingPeriod 2.1.866.20.1.3.1.2.25
The value of this object indicates a sampling period in seconds used by the statistics management function. The statistics management function determines the observed throughput by counting the octets sent or received on a line during this sampling period. More this sampling period is small, more precise is the evaluated throughput. This is a decimal integer in the range 10 to 1800 by step of 10. The default value is '60'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..1800  

fcmMgfStatOutputThreshold 2.1.866.20.1.3.1.2.26
The value of this object indicates a threshold in percents used by the statistics management function. The statistics management function calculates how long the observed outgoing throughput is superior to fcmMgfStatOuputThreshold percents of the maximum throughput of the line. This is a decimal integer in the range 0 to 100. The default value is '75'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fcmMgfStatInputThreshold 2.1.866.20.1.3.1.2.27
The value of this object indicates a threshold in percents used by the statistics management function. The statistics management function calculates how long the observed incoming throughput is superior to fcmMgfStatOuputThreshold percents of the maximum throughput of the line. This is a decimal integer in the range 0 to 100. The default value is '75'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fcmMgfStatLogChannelSamplingPeriod 2.1.866.20.1.3.1.2.30
The value of this object indicates a period in seconds used by the statistics management function. The statistics management function periodically counts the busy logical channels on a line every fcmMgfStatLogChannelSamplingPeriod seconds. This is a decimal integer in the range 10 to 1800 by step of 10. The default value is '60'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..1800  

fcmMgfStatLogChannelThreshold 2.1.866.20.1.3.1.2.31
The value of this object indicates a threshold in percents used by the statistics management function. The statistics management function calculates how long the observed number of the busy logical channels is superior to fcmMgfStatLogChannelThreshold percents of the maximum number of logical channels for a line. This is a decimal integer in the range 0 to 100. The default value is '75'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fcmMgfConversionAimedPoint 2.1.866.20.1.3.1.2.32
Conversion adresse : point vise
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcmMgfConversionIncomingCall 2.1.866.20.1.3.1.2.33
Conversion d'adresse sur appel entrant
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fcmMgfConversionOutgoingCall 2.1.866.20.1.3.1.2.34
Conversion adresse sur appel sortant
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fcmMgfConversionAddressCheck 2.1.866.20.1.3.1.2.35
Conversion adresse : controle de la presence dans les tables de conversion
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(4)  

fcmMgfConvMultiCalledAddrInCall 2.1.866.20.1.3.1.2.36
Numero d'identification pour conversion d'adresse d'appele multi-criteres en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fcmMgfConvMultiCallingAddrInCall 2.1.866.20.1.3.1.2.37
Numero d'identification pour conversion d'adresse d'appelant multi-criteres en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fcmMgfConvMultiCalledAddrOutCall 2.1.866.20.1.3.1.2.38
Numero d'identification pour conversion d'adresse d'appele multi-criteres en sortie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fcmMgfConvMultiCallingAddrOutCall 2.1.866.20.1.3.1.2.39
Numero d'identification pour conversion d'adresse d'appelant multi-criteres en sortie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fcmMgfBISDNChannelOpening 2.1.866.20.1.3.1.2.40
The value of this object describes the way ISDN backup will operate : off: B ISDN channel opening is automatic on: B ISDN channel opening is under management center control. A comparison is done between the calling address and the Manager and backup addresses defined in the management functions. If one of these addresses matches, the B ISDN channel is opened, otherwise the restart works only if the B channel is already open. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcmMgfCallAcceptwithReverseCharging 2.1.866.20.1.3.1.2.41
Acceptation appel avec TAD
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fcmMgfClosedUserGroup 2.1.866.20.1.3.1.2.42
GFA
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(2), clear(1), subscribe(3), subscribeAndRemove(4)  

fcmMgtFctCugTable 2.1.866.20.1.3.1.3
This table defines the configuration of four couples internal GFU / external GFU for each operating function.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcmMgtFctCugEntry

fcmMgtFctCugEntry 2.1.866.20.1.3.1.3.1
An entry of fcmMgtFctCugTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcmMgtFctCugEntry  

fcmMgtFctCugFunctionId 2.1.866.20.1.3.1.3.1.1
The value of this object defines the operating function
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER observation(1), statistics(2), outstandingEvents(3), alarm(4), trafficGeneration(5), telemaintenance(7), configuration(8), billing(10), extendedStatistics(11), pae(14)  

fcmMgtFctCugGroupId 2.1.866.20.1.3.1.3.1.2
The value of this object defines the number of the group for each couple internal GFU / external GFU This is a decimal integer in the range 0 to 3. The default value is '0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

fcmMgtFctCugClosedUserGroupExt 2.1.866.20.1.3.1.3.1.3
GFU externe This is a decimal integer in the range 0 to 99. The default value is ' '.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

fcmMgtFctCugClosedUserGroupInt 2.1.866.20.1.3.1.3.1.4
GFU interne The value of this object indicates a This is a decimal integer in the range 0 to 99. The default value is ' '.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

fcmMgtFctCugChecking 2.1.866.20.1.3.1.3.1.5
The value of this object defines on which call the equipment checks this CUG. The default values is 'onIncomingCallAndOutgoingCall'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER onOutgoingCall(3), onIncomingCallAndOutgoingCall(1)  

fcmAlarms 2.1.866.20.1.3.2
OBJECT IDENTIFIER    

fcmAlrmEventTable 2.1.866.20.1.3.2.1
This table defines, for each family, the selection of events which may be sent as alarms on the one hand, and as SNMP traps on the other hand. For most of these families, their events are sent for the physical ports selected in fcmAlrmPhysPortTable. It is not possible to add or delete an entry of this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcmAlrmEventEntry

fcmAlrmEventEntry 2.1.866.20.1.3.2.1.1
An entry of fcmAlrmEventTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcmAlrmEventEntry  

fcmAlrmEvtFamilyId 2.1.866.20.1.3.2.1.1.1
The value of this object identifies one and only one events family (the hexadecimal code of this family is the last part of the value-name). This entry selects events of this family which may be sent as alarms on the one hand, and as SNMP traps on the other hand.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER troubleReport-00(1), management-01(2), synchronousSignalling-02(3), x25SynchronousProcedure-03(4), synchronousLink-04(5), linePhysicalLevel-05(6), asynchronousProtocolLevel-06(7), asynchronousCommandSyntax-07(8), asynchronousSemanticLevel-08(9), sdlcProcedure-09(10), vipProcedure-0A(11), tvipFradBscProcedure-0B(12), dlcBscProcedure-0C(13), mlp-0D(14), pstnProcedure-0E(15), securizedVcEsv-0F(16), securizedVcN4-10(17), securizedVcIr-11(18), isdnDChannelProcedure-12(19), x29Rerouting-13(20), ethernetBridgeAndIpRouterFunctions-14(21), dlcMtrFrad-15(22), compressionProcedure-16(23), dlmFunction-17(24), configurationFunction-18(25), lmiFunction-19(26), ppp-1A(27), frameRelaySna-1B(28)  

fcmAlrmEvtEventSelection 2.1.866.20.1.3.2.1.1.2
The value of this object indicates whether all the events of this family are selected or only those mentioned for this family (in this case one to seven events may be selected). The default value is 'mentioned'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mentioned(1), all(2)  

fcmAlrmEvtEvent1 2.1.866.20.1.3.2.1.1.3
The value of this object is an event of this family which is selected when fcmAlrmEvtEventSelection is set to 'mentioned'. This is a one-byte octet string with 2 digits in the range 0 to F. The default value is 'FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcmAlrmEvtEvent2 2.1.866.20.1.3.2.1.1.4
The value of this object is an event of this family which is selected when fcmAlrmEvtEventSelection is set to 'mentioned'. This is a one-byte octet string with 2 digits in the range 0 to F. The default value is 'FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcmAlrmEvtEvent3 2.1.866.20.1.3.2.1.1.5
The value of this object is an event of this family which is selected when fcmAlrmEvtEventSelection is set to 'mentioned'. This is a one-byte octet string with 2 digits in the range 0 to F. The default value is 'FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcmAlrmEvtEvent4 2.1.866.20.1.3.2.1.1.6
The value of this object is an event of this family which is selected when fcmAlrmEvtEventSelection is set to 'mentioned'. This is a one-byte octet string with 2 digits in the range 0 to F. The default value is 'FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcmAlrmEvtEvent5 2.1.866.20.1.3.2.1.1.7
The value of this object is an event of this family which is selected when fcmAlrmEvtEventSelection is set to 'mentioned'. This is a one-byte octet string with 2 digits in the range 0 to F. The default value is 'FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcmAlrmEvtEvent6 2.1.866.20.1.3.2.1.1.8
The value of this object is an event of this family which is selected when fcmAlrmEvtEventSelection is set to 'mentioned'. This is a one-byte octet string with 2 digits in the range 0 to F. The default value is 'FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcmAlrmEvtEvent7 2.1.866.20.1.3.2.1.1.9
The value of this object is an event of this family which is selected when fcmAlrmEvtEventSelection is set to 'mentioned'. This is a one-byte octet string with 2 digits in the range 0 to F. The default value is 'FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcmAlrmPhysPortTable 2.1.866.20.1.3.2.2
This table defines, for each family, the selection of lines from which the events selected in fcmAlrmEventTable will be sent as alarms on the one hand, and as SNMP traps on the other hand. It is not possible to add or delete an entry of this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcmAlrmPhysPortEntry

fcmAlrmPhysPortEntry 2.1.866.20.1.3.2.2.1
An entry of fcmAlrmPhysPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcmAlrmPhysPortEntry  

fcmAlrmPpFamilyId 2.1.866.20.1.3.2.2.1.1
The value of this object identifies one and only one events family (the hexadecimal code of this family is the last part of the value-name). This entry selects lines from which the events selected in fcmAlrmEventTable will be sent as alarms on the one hand, and as SNMP traps on the other hand.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER troubleReport-00(1), management-01(2), synchronousSignalling-02(3), x25SynchronousProcedure-03(4), synchronousLink-04(5), linePhysicalLevel-05(6), asynchronousProtocolLevel-06(7), asynchronousCommandSyntax-07(8), asynchronousSemanticLevel-08(9), sdlcProcedure-09(10), vipProcedure-0A(11), tvipFradBscProcedure-0B(12), dlcBscProcedure-0C(13), mlp-0D(14), pstnProcedure-0E(15), isdnDChannelProcedure-12(19), dlcMtrFrad-15(22), compressionProcedure-16(23), dlmFunction-17(24), configurationFunction-18(25), lmiFunction-19(26), ppp-1A(27), frameRelaySna-1B(28)  

fcmAlrmPpPhysPortSelection 2.1.866.20.1.3.2.2.1.2
The value of this object indicates whether the selected events of this family are sent only for the physical ports mentioned for this family or for all the physical ports except those mentioned (note in this second case that all the physical ports are selected when none is specified). The default value is 'mentioned'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mentioned(1), allExceptMentioned(2)  

fcmAlrmPpPhysPort1 2.1.866.20.1.3.2.2.1.3
The value of this object is a physical port for which the selected events of this family will be or will not be sent according to fcmAlrmPpPhysPortSelection. This is a decimal integer in the range 0 to 35. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fcmAlrmPpPhysPort2 2.1.866.20.1.3.2.2.1.4
The value of this object is a physical port for which the selected events of this family will be or will not be sent according to fcmAlrmPpPhysPortSelection. This is a decimal integer in the range 0 to 35. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fcmAlrmPpPhysPort3 2.1.866.20.1.3.2.2.1.5
The value of this object is a physical port for which the selected events of this family will be or will not be sent according to fcmAlrmPpPhysPortSelection. This is a decimal integer in the range 0 to 35. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fcmAlrmPpPhysPort4 2.1.866.20.1.3.2.2.1.6
The value of this object is a physical port for which the selected events of this family will be or will not be sent according to fcmAlrmPpPhysPortSelection. This is a decimal integer in the range 0 to 35. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fcmAlrmPpPhysPort5 2.1.866.20.1.3.2.2.1.7
The value of this object is a physical port for which the selected events of this family will be or will not be sent according to fcmAlrmPpPhysPortSelection. This is a decimal integer in the range 0 to 35. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fcmAlrmPpPhysPort6 2.1.866.20.1.3.2.2.1.8
The value of this object is a physical port for which the selected events of this family will be or will not be sent according to fcmAlrmPpPhysPortSelection. This is a decimal integer in the range 0 to 35. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fcmAlrmPpPhysPort7 2.1.866.20.1.3.2.2.1.9
The value of this object is a physical port for which the selected events of this family will be or will not be sent according to fcmAlrmPpPhysPortSelection. This is a decimal integer in the range 0 to 35. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fcInterfaces 2.1.866.20.1.10
OBJECT IDENTIFIER    

fcfPhysicalPortTable 2.1.866.20.1.10.1
This table defines how the physical ports of the equipment are used to build the interfaces. It is not possible to add or delete an entry of this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfPhysicalPortEntry

fcfPhysicalPortEntry 2.1.866.20.1.10.1.1
An entry of fcfPhysicalPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfPhysicalPortEntry  

fcfPhysPortId 2.1.866.20.1.10.1.1.1
The value of this object identifies one and only one physical port. A physical port has the same number than the physical connector which it goes with (this number is indicated on the equipment). This is a decimal integer in the range 0 to the number of the physical ports minus 1 (36 at the most).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..36  

fcfPhysPortConnector 2.1.866.20.1.10.1.1.2
The value of this object indicates whether the connector type is Ethernet or DB25 or RJ45.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet(1), db25orRj45(2), link(3), db9orRj45(4)  

fcfInterfaceType 2.1.866.20.1.10.1.1.3
The value of this object indicates how this physical port is used to build an interface (the interface identifiers are set by the equipment) : unUsed : this physical port is not used, ethernetAui : this physical port will support an ethernet interface with the same identifier (AUI connector for 10 base 5 ethernet), ethernet10baseT : this physical port will support an ethernet interface with the same identifier (RJ 45 connector for 10 base T ethernet), ethernetAuto : this physical port will support an ethernet interface with the same identifier (automatic detection between 10 base 5 and 10 base T), line : this physical port will support a serial line interface with the same identifier (the characteristics of this serial line interface are described in fcfLineTable), isdnBChannel : this physical port will support a B-channel of an ISDN Basic Rate Interface, isdnDChannel : this physical port will support a D-channel of an ISDN Basic Rate Interface with the same identifier (the characteristics of this ISDN BRI are described in fcfIsdnBasicRateInterfaceTable). interUnitLinks : this physical port will support a UnitLinks Interface, e1 : this physical port will support a E1 Interface, ds1 : this physical port will support a DS1 Interface, isdnPri : this physical port will support a Primary Rate Interface, tokenRing : this physical port will support a token ring Interface, analogVoiceEM : this physical port will support a EM analog voice Interface, analogVoiceFxs : this physical port will support a Fxs analog voice Interface, analogVoiceFxo : this physical port will support a Fxo analog voice Interface, isdnBri : this physical port will support a Basic Rate Interface, Each equipment has its own characteristics and the building of the interfaces must be done according to its hardware limitations. The default value is 'unUsed'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unUsed(1), ethernetAuto(2), ethernet10baseT(3), ethernetAui(4), line(5), isdnBChannel(6), isdnDChannel(7), interUnitLinks(8), e1(9), ds1(10), isdnPri(11), lineorB(12), tokenRing(13)  

fcfLines 2.1.866.20.1.10.2
OBJECT IDENTIFIER    

fcfLineTable 2.1.866.20.1.10.2.1
This table defines the characteristics of the serial line interfaces. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfPhysicalPortTable, to one instance of fcfInterfaceType equal to 'line').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineEntry

fcfLineEntry 2.1.866.20.1.10.2.1.1
An entry of fcfLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineEntry  

fcfLineInterfaceId 2.1.866.20.1.10.2.1.1.1
The value of this object identifies one and only one serial line interface. Each serial line interface corresponds, in fcfPhysicalPortTable, to one instance of fcfInterfaceType equal to 'line'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineType 2.1.866.20.1.10.2.1.1.2
The value of this object indicates which DTE/DCE interface characteristics (physical layer) are used on this serial line interface : synchronousV28Dte : Synchronous, V28, the equipment is a DTE, synchronousV28Dce : Synchronous, V28, the equipment is a DCE, asynchronousV28Dte : Asynchronous, V28, the equipment is a DTE, asynchronousV28Dce : Asynchronous, V28, the equipment is a DCE, v11Dte : Synchronous, V11, the equipment is a DTE, v11Dce : Synchronous, V11, the equipment is a DCE, v35Dte : Synchronous, V35, the equipment is a DTE, v35Dce : Synchronous, V35, the equipment is a DCE, g703 : G703. The selection of this type must be done according to the hardware characteristics of this serial line interface. The default value is 'synchronousV28Dte'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER synchroneV28Dte(1), synchroneV28Dce(2), asynchroneV28Dte(3), asynchroneV28Dce(4), v11Dte(5), v11Dce(6), v35Dte(7), v35Dce(8), g703(9)  

fcfLineModemManagement 2.1.866.20.1.10.2.1.1.3
The value of this object indicates whether a modem is drived by the equipment or not. The characteristics of the modem are described in fcfLineModemTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineSpeed 2.1.866.20.1.10.2.1.1.4
The value of this object indicates the speed in bits per second used on this serial line interface. The values s300, s57600 and s115200 can not be used on synchronous serial line interfaces. The default value is 's19200'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s300(23), s600(2), s1200(3), s2400(6), s3200(7), s4800(8), s9600(10), s14400(9), s19200(11), s28800(26), s38400(12), s48000(13), s56000(14), s57600(24), s64000(15), s72000(16), s115200(25), s128000(17), s144000(18), s256000(19), s512000(20), s1024000(21), s2048000(22)  

fcfLineLinkCheckPeriod 2.1.866.20.1.10.2.1.1.5
The value of this object indicates a period in milliseconds used to look after the circuits of this serial line interface. Each circuit state is checked every fcfLineLinkCheckPeriod milliseconds and when it changes and remains changed after fcfLineCheckPeriodCount checkings, this new state is delivered to the upper level. This is a decimal integer in the range 200 to 50800 by step of 200. The default value is '2000'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 200..50800  

fcfLineCheckPeriodCount 2.1.866.20.1.10.2.1.1.6
The value of this object indicates the number of checkings of the circuits of this serial line interface. Each circuit state is checked every fcfLineLinkCheckPeriod milliseconds and when it changes and remains changed after fcfLineCheckPeriodCount checkings, this new state is delivered to the upper level. This is a decimal integer in the range 1 to 250. The default value is '3'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..250  

fcfLineV28AsynOutDteSignalTable 2.1.866.20.1.10.2.5
This table defines how the outgoing circuits are used on asynchronous V28 serial line interfaces when the equipment is a DTE. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'asynchronousV28Dte').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineV28AsynOutDteSignalEntry

fcfLineV28AsynOutDteSignalEntry 2.1.866.20.1.10.2.5.1
An entry of fcfLineV28AsynOutDteSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineV28AsynOutDteSignalEntry  

fcfLineV28AsynOutDteInterfaceId 2.1.866.20.1.10.2.5.1.1
The value of this object identifies one and only one asynchronous V28 DTE serial line interface. Each asynchronous V28 DTE serial line interface corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'asynchronousV28Dte'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineV28AsynOutDteRts105 2.1.866.20.1.10.2.5.1.2
The value of this object defines whether the circuit 105 (request to send) is set, in any case, to 'on' or to 'off'. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineV28AsynOutDteDtr108 2.1.866.20.1.10.2.5.1.3
The value of this object defines whether the circuit 108 (108/1 : connect data set to line or 108/2 : data terminal ready) is set, in any case, to 'on' or to 'off'. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineV28AsynOutDteDrs111 2.1.866.20.1.10.2.5.1.4
The value of this object defines whether the circuit 111 (data signalling rate selector) is set, in any case, to 'on' or to 'off'. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineV28AsynOutDteRil140 2.1.866.20.1.10.2.5.1.5
The value of this object defines whether the circuit 140 (loopback / maintance test) is set, in any case, to 'on' or to 'off'. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineV28AsynOutDteLl141 2.1.866.20.1.10.2.5.1.6
The value of this object defines whether the circuit 141 (local loopback) is set, in any case, to 'on' or to 'off'. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineV28AsynOutDceSignalTable 2.1.866.20.1.10.2.6
This table defines how the outgoing circuits are used on asynchronous V28 serial line interfaces when the equipment is a DCE. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'asynchronousV28Dce').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineV28AsynOutDceSignalEntry

fcfLineV28AsynOutDceSignalEntry 2.1.866.20.1.10.2.6.1
An entry of fcfLineV28AsynOutDceSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineV28AsynOutDceSignalEntry  

fcfLineV28AsynOutDceInterfaceId 2.1.866.20.1.10.2.6.1.1
The value of this object identifies one and only one asynchronous V28 DCE serial line interface. Each asynchronous V28 DCE serial line interface corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'asynchronousV28Dce'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineV28AsynOutDceCts106 2.1.866.20.1.10.2.6.1.2
The value of this object defines whether the circuit 106 (ready for sending) is set, in any case, to 'on' or to 'off'. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineV28AsynOutDceDsr107 2.1.866.20.1.10.2.6.1.3
The value of this object defines whether the circuit 107 (data set ready) is set, in any case, to 'on' or to 'off'. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineV28AsynOutDceDcd109 2.1.866.20.1.10.2.6.1.4
The value of this object defines whether the circuit 109 (data channel received line signal detector) is set, in any case, to 'on' or to 'off'. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineV28AsynOutDceSi117 2.1.866.20.1.10.2.6.1.5
The value of this object defines whether the circuit 117 (standby indicator) is set, in any case, to 'on' or to 'off'. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineV28AsynOutDceTi142 2.1.866.20.1.10.2.6.1.6
The value of this object defines whether the circuit 142 (test indicator) is set, in any case, to 'on' or to 'off'. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineV28AsynInDteSignalTable 2.1.866.20.1.10.2.7
This table defines how the incoming circuits are interpreted on asynchronous V28 serial line interfaces when the equipment is a DTE. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'asynchronousV28Dte').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineV28AsynInDteSignalEntry

fcfLineV28AsynInDteSignalEntry 2.1.866.20.1.10.2.7.1
An entry of fcfLineV28AsynInDteSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineV28AsynInDteSignalEntry  

fcfLineV28AsynInDteInterfaceId 2.1.866.20.1.10.2.7.1.1
The value of this object identifies one and only one asynchronous V28 DTE serial line interface. Each asynchronous V28 DTE serial line interface corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'asynchronousV28Dte'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineV28AsynInDteEnablingSig1 2.1.866.20.1.10.2.7.1.2
The value of this object defines which circuits are scanned to determine whether this serial line interface is up or down. Secondary circuits may also be simultaneously scanned (see fcfLineV28AsynInDteEnablingSig2). none : the circuits 106, 107, 109 are not used. If also the circuits 117 and 142 are not used the state of this interface is determined by another method, cts106 : the circuit 106 (ready for sending) is used, dsr107 : the circuit 107 (data set ready) is used, dcd109 : the circuit 109 (data channel received line signal detector) is used, cts106-dsr107 : both circuits 106 and 107 are used, cts106-dcd109 : both circuits 106 and 109 are used, dsr107-dcd109 : both circuits 107 and 109 are used, cts106-dsr107-dcd109 : both circuits 106, 107 and 109 are used. The default value is 'cts106'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), cts106(33), dsr107(2), dcd109(9), cts106-dsr107(34), cts106-dcd109(41), dsr107-dcd109(10), cts106-dsr107-dcd109(42)  

fcfLineV28AsynInDteEnablingSig2 2.1.866.20.1.10.2.7.1.3
The value of this object defines which circuits are scanned to determine whether this serial line interface is up or down. Main circuits may also be simultaneously scanned (see fcfLineV28AsynInDteEnablingSig1). none : the circuits 117, 142 are not used. If also the circuits 106, 107 and 109 are not used the state of this interface is determined by another method, si117 : the circuit 117 (standby indicator) is used, ti142 : the circuit 142 (test indicator) is used. The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), si117(5), ti142(3)  

fcfLineV28AsynInDteSigMonitored1 2.1.866.20.1.10.2.7.1.4
The value of this object defines which circuits are monitored to eventually generate the corresponding event when the state of one of them changes. Secondary circuits may also be simultaneously monitored (see fcfLineV28AsynInDteMonitored2). none : the circuits 106, 107, 109 are not monitored, cts106 : the circuit 106 (ready for sending) is monitored, dsr107 : the circuit 107 (data set ready) is monitored, dcd109 : the circuit 109 (data channel received line signal detector) is monitored, cts106-dsr107 : both circuits 106 and 107 are monitored, cts106-dcd109 : both circuits 106 and 109 are monitored, dsr107-dcd109 : both circuits 107 and 109 are monitored, cts106-dsr107-dcd109 : both circuits 106, 107 and 109 are monitored. The default value is 'cts106'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), cts106(33), dsr107(2), dcd109(9), cts106-dsr107(34), cts106-dcd109(41), dsr107-dcd109(10), cts106-dsr107-dcd109(42)  

fcfLineV28AsynInDteSigMonitored2 2.1.866.20.1.10.2.7.1.5
The value of this object defines which circuits are monitored to eventually generate the corresponding event when the state of one of them changes. Main circuits may also be simultaneously monitored (see fcfLineV28AsynInDteMonitored1). none : the circuits 117, 142 are not monitored, si117 : the circuit 117 (standby indicator) is monitored, ti142 : the circuit 142 (test indicator) is monitored. The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), si117(5), ti142(3)  

fcfLineV28AsynInDceSignalTable 2.1.866.20.1.10.2.8
This table defines how the incoming circuits are interpreted on asynchronous V28 serial line interfaces when the equipment is a DCE. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'asynchronousV28Dce').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineV28AsynInDceSignalEntry

fcfLineV28AsynInDceSignalEntry 2.1.866.20.1.10.2.8.1
An entry of fcfLineV28AsynInDceSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineV28AsynInDceSignalEntry  

fcfLineV28AsynInDceInterfaceId 2.1.866.20.1.10.2.8.1.1
The value of this object identifies one and only one asynchronous V28 DCE serial line interface. Each asynchronous V28 DCE serial line interface corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'asynchronousV28Dce'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineV28AsynInDceEnablingSig1 2.1.866.20.1.10.2.8.1.2
The value of this object defines which circuits are scanned to determine whether this serial line interface is up or down. Secondary circuits may also be simultaneously scanned (see fcfLineV28AsynInDceEnablingSig2). none : the circuits 105, 108 are not used. If also the circuits 111, 140 and 141 are not used the state of this interface is determined by another method, rts105 : the circuit 105 (request to send) is used, dtr108 : the circuit 108 (108/1 connect data set to line, 108/2 data terminal ready) is used, rts105-dtr108 : both circuits 105 and 108 are used. The default value is 'rts105'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), rts105(9), dtr108(33), rts105-dtr108(41)  

fcfLineV28AsynInDceEnablingSig2 2.1.866.20.1.10.2.8.1.3
The value of this object defines which circuits are scanned to determine whether this serial line interface is up or down. Main circuits may also be simultaneously scanned (see fcfLineV28AsynInDceEnablingSig1). none : the circuits 111, 140, 141 are not used. If also the circuits 105 and 108 are not used the state of this interface is determined by another method, drs111 : the circuit 111 (data signal rate selector) is used, ril140 : the circuit 140 (loopback / maintenance test) is used, ll141 : the circuit 141 (local loopback) is used. The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), drs111(2), ril140(3), ll141(5)  

fcfLineV28AsynInDceSigMonitored1 2.1.866.20.1.10.2.8.1.4
The value of this object defines which circuits are monitored to eventually generate the corresponding event when the state of one of them changes. Secondary circuits may also be simultaneously monitored (see fcfLineV28AsynInDceMonitored2). none : the circuits 105, 108 are not monitored, rts105 : the circuit 105 (request to send) is monitored, dtr108 : the circuit 108 (108/1 connect data set to line, 108/2 data terminal ready) is monitored, rts105-dtr108 : both circuits 105 and 108 are monitored. The default value is 'rts105'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), rts105(9), dtr108(33), rts105-dtr108(41)  

fcfLineV28AsynInDceSigMonitored2 2.1.866.20.1.10.2.8.1.5
The value of this object defines which circuits are monitored to eventually generate the corresponding event when the state of one of them changes. Main circuits may also be simultaneously monitored (see fcfLineV28AsynInDceMonitored1). none : the circuits 111, 140, 141 are not monitored, drs111 : the circuit 111 (data signal rate selector) is monitored, ril140 : the circuit 140 (loopback / maintenance test) is monitored, ll141 : the circuit 141 (local loopback) is monitored. The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), rts111(2), ril140(3), ll141(5)  

fcfLineV28DteSignalTable 2.1.866.20.1.10.2.11
This table defines how the incoming circuits are monitored and interpreted on synchronous V28 serial line interfaces when the equipment is a DTE. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'synchronousV28Dte').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineV28DteSignalEntry

fcfLineV28DteSignalEntry 2.1.866.20.1.10.2.11.1
An entry of fcfLineV28DteSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineV28DteSignalEntry  

fcfLineV28DteInterfaceId 2.1.866.20.1.10.2.11.1.1
The value of this object identifies one and only one synchronous V28 DTE serial line interface. Each synchronous V28 DTE serial line interface corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'synchronousV28Dte'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineV28DteCts106 2.1.866.20.1.10.2.11.1.2
The value of this object defines how the circuit 106 (ready fo sending) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV28DteDsr107 2.1.866.20.1.10.2.11.1.3
The value of this object defines how the circuit 107 (data set ready) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV28DteDcd109 2.1.866.20.1.10.2.11.1.4
The value of this object defines how the circuit 109 (data channel received line signal detector) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV28DteSi117 2.1.866.20.1.10.2.11.1.5
The value of this object defines how the circuit 117 (standby indicator) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV28DteTi142 2.1.866.20.1.10.2.11.1.6
The value of this object defines how the circuit 142 (test indicator) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV28DteSyn 2.1.866.20.1.10.2.11.1.7
The value of this object defines how the flags are checked to determine whether this serial line interface is up or down. notMonitored : the flags are not checked, monitoredOff : the flags are checked and they must be not present to determine that this serial line interface is in the UP state, monitoredOn : the flags are checked and they must be present to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredOff(2), monitoredOn(3)  

fcfLineV28DceSignalTable 2.1.866.20.1.10.2.12
This table defines how the incoming circuits are monitored and interpreted on synchronous V28 serial line interfaces when the equipment is a DCE. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'synchronousV28Dce').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineV28DceSignalEntry

fcfLineV28DceSignalEntry 2.1.866.20.1.10.2.12.1
An entry of fcfLineV28DceSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineV28DceSignalEntry  

fcfLineV28DceInterfaceId 2.1.866.20.1.10.2.12.1.1
The value of this object identifies one and only one synchronous V28 DCE serial line interface. Each synchronous V28 DCE serial line interface corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'synchronousV28Dce'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineV28DceRts105 2.1.866.20.1.10.2.12.1.2
The value of this object defines how the circuit 105 (request to send) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV28DceDtr108 2.1.866.20.1.10.2.12.1.3
The value of this object defines how the circuit 108 (108/1 connect data set to line, 108/2 data terminal ready) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV28DceDrs111 2.1.866.20.1.10.2.12.1.4
The value of this object defines how the circuit 111 (data signal rate selector) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV28DceRil140 2.1.866.20.1.10.2.12.1.5
The value of this object defines how the circuit 140 (loopback / maintenance test) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV28DceLl141 2.1.866.20.1.10.2.12.1.6
The value of this object defines how the circuit 141 (local loopback) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV28DceSyn 2.1.866.20.1.10.2.12.1.7
The value of this object defines how the flags are checked to determine whether this serial line interface is up or down. notMonitored : the flags are not checked, monitoredOff : the flags are checked and they must be not present to determine that this serial line interface is in the UP state, monitoredOn : the flags are checked and they must be present to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredOff(2), monitoredOn(3)  

fcfLineV11DteSignalTable 2.1.866.20.1.10.2.15
This table defines how the incoming circuits are monitored and interpreted on synchronous V11 serial line interfaces when the equipment is a DTE. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'synchronousV11Dte').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineV11DteSignalEntry

fcfLineV11DteSignalEntry 2.1.866.20.1.10.2.15.1
An entry of fcfLineV11DteSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineV11DteSignalEntry  

fcfLineV11DteInterfaceId 2.1.866.20.1.10.2.15.1.1
The value of this object identifies one and only one synchronous V11 DTE serial line interface. Each synchronous V11 DTE serial line interface corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'synchronousV11Dte'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineV11DteIndication109 2.1.866.20.1.10.2.15.1.2
The value of this object defines how the circuit 109 (I, indication) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV11DteSyn 2.1.866.20.1.10.2.15.1.3
The value of this object defines how the flags are checked to determine whether this serial line interface is up or down. notMonitored : the flags are not checked, monitoredOff : the flags are checked and they must be not present to determine that this serial line interface is in the UP state, monitoredOn : the flags are checked and they must be present to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredOff(2), monitoredOn(3)  

fcfLineV11DceSignalTable 2.1.866.20.1.10.2.16
This table defines how the incoming circuits are monitored and interpreted on synchronous V11 serial line interfaces when the equipment is a DCE. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'synchronousV11Dce').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineV11DceSignalEntry

fcfLineV11DceSignalEntry 2.1.866.20.1.10.2.16.1
An entry of fcfLineV11DceSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineV11DceSignalEntry  

fcfLineV11DceInterfaceId 2.1.866.20.1.10.2.16.1.1
The value of this object identifies one and only one synchronous V11 DCE serial line interface. Each synchronous V11 DCE serial line interface corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'synchronousV11Dce'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineV11DceControl105 2.1.866.20.1.10.2.16.1.2
The value of this object defines how the circuit 105 (C, control) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV11DceSyn 2.1.866.20.1.10.2.16.1.3
The value of this object defines how the flags are checked to determine whether this serial line interface is up or down. notMonitored : the flags are not checked, monitoredOff : the flags are checked and they must be not present to determine that this serial line interface is in the UP state, monitoredOn : the flags are checked and they must be present to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredOff(2), monitoredOn(3)  

fcfLineV35DteSignalTable 2.1.866.20.1.10.2.19
This table defines how the incoming circuits are monitored and interpreted on V35 serial line interfaces when the equipment is a DTE. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'v35Dte').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineV35DteSignalEntry

fcfLineV35DteSignalEntry 2.1.866.20.1.10.2.19.1
An entry of fcfLineV35DteSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineV35DteSignalEntry  

fcfLineV35DteInterfaceId 2.1.866.20.1.10.2.19.1.1
The value of this object identifies one and only one V35 DTE serial line interface. Each V35 DTE serial line interface corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'v35Dte'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineV35DteD106 2.1.866.20.1.10.2.19.1.2
The value of this object defines how the circuit 106 (pin D, ready fo sending) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV35DteE107 2.1.866.20.1.10.2.19.1.3
The value of this object defines how the circuit 107 (pin E, data set ready) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV35DteF109 2.1.866.20.1.10.2.19.1.4
The value of this object defines how the circuit 109 (pin F, data channel received line signal detector) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV35DteTi142 2.1.866.20.1.10.2.19.1.5
The value of this object defines how the circuit 142 (pin NN, test indicator) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV35DteSyn 2.1.866.20.1.10.2.19.1.6
The value of this object defines how the flags are checked to determine whether this serial line interface is up or down. notMonitored : the flags are not checked, monitoredOff : the flags are checked and they must be not present to determine that this serial line interface is in the UP state, monitoredOn : the flags are checked and they must be present to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'..
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredOff(2), monitoredOn(3)  

fcfLineV35DceSignalTable 2.1.866.20.1.10.2.20
This table defines how the incoming circuits are monitored and interpreted on V35 serial line interfaces when the equipment is a DCE. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'v35Dce').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineV35DceSignalEntry

fcfLineV35DceSignalEntry 2.1.866.20.1.10.2.20.1
An entry of fcfLineV35DceSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineV35DceSignalEntry  

fcfLineV35DceInterfaceId 2.1.866.20.1.10.2.20.1.1
The value of this object identifies one and only one V35 DCE serial line interface. Each V35 DCE serial line interface corresponds, in fcfLineTable, to one instance of fcfLineType equal to 'v35Dce'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineV35DceC105 2.1.866.20.1.10.2.20.1.2
The value of this object defines how the circuit 105 (pin C, request to send) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV35DceH108 2.1.866.20.1.10.2.20.1.3
The value of this object defines how the circuit 108 (pin H, 108/1 connect data set to line, 108/2 data terminal ready) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV35DceRil140 2.1.866.20.1.10.2.20.1.4
The value of this object defines how the circuit 140 (pin N, loopback / maintenance test) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV35DceLl141 2.1.866.20.1.10.2.20.1.5
The value of this object defines how the circuit 141 (pin L, local loopback) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4)  

fcfLineV35DceSyn 2.1.866.20.1.10.2.20.1.6
The value of this object defines how the flags are checked to determine whether this serial line interface is up or down. notMonitored : the flags are not checked, monitoredOff : the flags are checked and they must be not present to determine that this serial line interface is in the UP state, monitoredOn : the flags are checked and they must be present to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notMonitored(1), monitoredOff(2), monitoredOn(3)  

fcfLineModem 2.1.866.20.1.10.2.30
OBJECT IDENTIFIER    

fcfLineModemTable 2.1.866.20.1.10.2.30.1
This table defines, for each serial line interface facing to a modem, how this modem is managed. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfLineTable, to one instance of fcfLineModemManagement equal to 'on').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineModemEntry

fcfLineModemEntry 2.1.866.20.1.10.2.30.1.1
An entry of fcfLineModemTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineModemEntry  

fcfLineModInterfaceId 2.1.866.20.1.10.2.30.1.1.1
The value of this object identifies one and only one serial line interface facing to a modem. Each of these serial line interfaces corresponds, in fcfLineTable, to one instance of fcfLineModemManagement equal to 'on'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineModType 2.1.866.20.1.10.2.30.1.1.2
The value of this object defines how the automatic calling and/or answering data stations is operated on this serial line interface : direct : The 'direct call and/or answer controlled by the DTE (circuit 108/1)' mode gives to the equipment (in DTE mode) the capacity of calling a number pre-recorded in the modem (in DCE mode), by means of the 108/1 control circuit. It gives also to the equipment the capacity of accepting incoming calls on a'per call' basis. addressedAt : The 'addressed call and/or answer authorized by the DTE (circuit 108/2)' mode gives to the equipment (in DTE mode) extensive facilities by means of instructions exchanged between the DTE and the DCE on circuits 103 (transmitted data) and 104 (received data). It gives also to the equipment the capacity to accept 'a priori' an incoming call. The commands / indications use the AT format. addressedV25Bis : The 'addressed call and/or answer authorized by the DTE (circuit 108/2)' mode gives to the equipment (in DTE mode) extensive facilities by means of instructions exchanged between the DTE and the DCE on circuits 103 (transmitted data) and 104 (received data). It gives also to the equipment the capacity to accept 'a priori' an incoming call. The commands / indications use the ITU-T V.25 bis recommendation format. The default value is 'addressedV25Bis'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER direct(1), addressedAt(2), addressedV25Bis(3)  

fcfLineModLinkUpTimer 2.1.866.20.1.10.2.30.1.1.3
The value of this object is the management timer in seconds for this serial line interface. It starts when the first call request is sent to the modem and it is normally stopped when the serial line interface is 'up'. The serial line interface state is set to 'down' when this timer runs out. The value of this timer must be larger than the total duration of the successive dialling attempts to not interrupt this processing (see fcfLineModNewDiallingTimer and fcfLineModDiallingCount). This is a decimal integer in the range 1 to 250. The default value is '180'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..250  

fcfLineModNewDiallingTimer 2.1.866.20.1.10.2.30.1.1.4
The value of this object is the dialling timer in seconds for this serial line interface. It starts when a call request is sent to the modem and it is normally stopped when the call is successfull or when the modem answers with an error message. The call request is sent again when this timer runs out. After transmission of the call request fcfLineModDiallingCount times the serial line interface state is set to 'down'. This is a decimal integer in the range 0 to 2500 by step of 10. The default value is '30'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2500  

fcfLineModDiallingCount 2.1.866.20.1.10.2.30.1.1.5
The value of this object is the maximum number of attempts to complete a sucessfull call for this serial line interface. A new call request is sent to the modem when fcfLineModNewDiallingTimer runs out. This is a decimal integer in the range 0 to 250. The default value is '3'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fcfLineModUnuseTimer 2.1.866.20.1.10.2.30.1.1.6
The value of this object is the unuse timer in seconds for this serial line interface. This function is specified in order to clear a call when no communications are established on it. This timer starts upon the clearing of the last communication using this call and it is normally stopped when a new one is initiated. The equipment clears the call when this timer runs out. The value '0' disables the processing of this timer. This is a decimal integer in the range 0 to 250 by step of 10. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..254  

fcfLineModSpeed 2.1.866.20.1.10.2.30.1.1.7
The value of this object indicates the speed in bits per second used between the equipment and the modem for this serial line interface. The other characteristics of this communication are : no parity, one stop bit, eight bits per character. The default value is 's9600'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s150(1), s300(2), s600(3), s1200(4), s2400(5), s4800(9), s9600(11), s19200(12), s28800(13), s38400(14), s57600(15), s115200(16)  

fcfLineModCallDirection 2.1.866.20.1.10.2.30.1.1.8
The value of this object defines the mode used to establish the connection with the remote system for this serial line interface : calling : the caller is the equipment, called : the caller is the remote system, auto : automatic choise between 'calling' and 'called' (not accepted when fcfLineModType is set to 'direct'). The default value is 'auto'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER calling(3), called(2), auto(1)  

fcfLineModInitString 2.1.866.20.1.10.2.30.1.1.9
The value of this object is a characters string sent by the equipment to the modem when the state of this serial line interface becomes 'up'. This is a 0 to 50 ASCII characters string. The default value is the empty string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..50)  

fcfLineModOutputXidString 2.1.866.20.1.10.2.30.1.1.10
The value of this object indicates, for this serial line interface, whether an XID string is sent by the equipment or not prior to the estblishment of any virtual call (exchange identification procedure). This XID string is defined by fcfLineModOutputXidStringId. This mechanism may be enabled only when this serial line interface is used by the X25 protocol. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineModOutputXidStringId 2.1.866.20.1.10.2.30.1.1.11
The value of this object indicates, for this serial line interface, which XID string will be sent by the equipment prior to the estblishment of any virtual call (exchange identification procedure). This XID string is defined in fcfLineModXidStringTable. This is a decimal integer in the range 0 to 3. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

fcfLineModInputXidString 2.1.866.20.1.10.2.30.1.1.12
The value of this object indicates, for this serial line interface, whether an XID string will be received by the equipment or not prior to the estblishment of any virtual call (exchange identification procedure). If yes fcfLineModInputXidStringCount defines how many XID strings will be received. This mechanism may be enabled only when this serial line interface is used by the X25 protocol. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfLineModInputXidStringCount 2.1.866.20.1.10.2.30.1.1.13
The value of this object defines, for this serial line interface, how many XID strings will be received by the equipment prior to the estblishment of any virtual call (exchange identification procedure) if this mechanism is enabled (see fcfLineModInputXidString). This is a decimal integer in the range 0 to 250. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fcfLineModXidStringTable 2.1.866.20.1.10.2.30.2
This table contains the XID strings that are sent by the equipment prior to the estblishment of any virtual call (exchange identification procedure) on serial line interfaces according to fcfLineModOutputXidString. An XID string, identified by fcfLineModXidStringId, is the concatenation, in ascending order of fcfLineModXidStringEltNum, of 1 to 4 elements of 0 to 32 bytes. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fcfLineModXidStringEltStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineModXidStringEntry

fcfLineModXidStringEntry 2.1.866.20.1.10.2.30.2.1
An entry of fcfLineModXidStringTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineModXidStringEntry  

fcfLineModXidStringId 2.1.866.20.1.10.2.30.2.1.1
The value of this object identifies one and only one XID string which is sent by the equipment prior to the estblishment of any virtual call (exchange identification procedure) on serial line interfaces according to fcfLineModOutputXidString. This XID string is the concatenation, in ascending order of fcfLineModXidStringEltNum, of 1 to 4 elements of 0 to 32 bytes. This is a decimal integer in the range 0 to 3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

fcfLineModXidStringEltNum 2.1.866.20.1.10.2.30.2.1.2
The value of this object identifies one and only one element of this XID string. The whole XID string is the concatenation, in ascending order of this value, of all of its elements. This is a decimal integer in the range 1 to 4.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

fcfLineModXidStringEltStatus 2.1.866.20.1.10.2.30.2.1.3
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcfLineModXidStringElement 2.1.866.20.1.10.2.30.2.1.4
The value of this object contains the bytes of this element of this XID string. The whole XID string is the concatenation, in ascending order of fcfLineModXidStringEltNum, of all of its elements. This is a thirty-three-bytes octet string with up to 66 digits in the range 0 to F. The first byte contains the number of following useful bytes. It must be padded with 'F' digits for a total of 66 digits. The equipment configurator does not need this final padding neither the first byte (which is automatically updated). The default value is 'empty' : first byte set to '00', others set to 'FF' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(33)  

fcfLineDVBTable 2.1.866.20.1.10.2.31
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfLineDVBEntry

fcfLineDVBEntry 2.1.866.20.1.10.2.31.1
An entry of fcfLineDVBTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfLineDVBEntry  

fcfLineDVBInterfaceId 2.1.866.20.1.10.2.31.1.1
IF id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfLineDVBStatus 2.1.866.20.1.10.2.31.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcfLineDVBConnection 2.1.866.20.1.10.2.31.1.3
Link with DVB
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), lsForDvb1(2), lsForDvb2(3)  

fcfIsdn 2.1.866.20.1.10.5
OBJECT IDENTIFIER    

fcfIsdnBasicRateInterfaceTable 2.1.866.20.1.10.5.1
This table defines the characteristics of the integrated services digital network (ISDN) basic rate interfaces (BRI). It is not possible to add or delete an entry of this table (each entry corresponds, in fcfPhysicalPortTable, to one instance of fcfInterfaceType equal to 'isdnDChannel').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfIsdnBasicRateInterfaceEntry

fcfIsdnBasicRateInterfaceEntry 2.1.866.20.1.10.5.1.1
An entry of fcfIsdnBasicRateInterfaceTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfIsdnBasicRateInterfaceEntry  

fcfIsdnBasicRateInterfaceId 2.1.866.20.1.10.5.1.1.1
The value of this object identifies one and only one integrated services digital network (ISDN) basic rate interface (BRI). Each ISDN BRI corresponds, in fcfPhysicalPortTable, to one instance of fcfInterfaceType equal to 'isdnDChannel' or 'isdnBri'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfIsdnBriSignalling 2.1.866.20.1.10.5.1.1.2
The value of this object indicates, for this basic rate interface, whether signalling is enabled or not. It must be set to 'on' to use the B-channels. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfIsdnBriCountry 2.1.866.20.1.10.5.1.1.3
The value of this object permits to take into account the national characteristics of some ISDN implementations : franceVn2 : France VN 2 implementation, franceVn3 : France VN 3 implementation, franceVn4 : France VN 4 implementation, unitedKingdom : France VN 2 implementation, switzerland : Switzerland implementation, europeanIsdn : Europe implementation. japan : japan implementation. usa : usa implementation. The default value is 'europeanIsdn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER franceVn2(1), franceVn3(2), unitedKingdom(3), switzerland(4), europeanIsdn(5), japan(6)  

fcfIsdnBriInterfaceCheckPeriod 2.1.866.20.1.10.5.1.1.4
The value of this object indicates a period in milliseconds of detection of power source 1 or power source 2, whichever may be provided for this basic rate interface. The power source is checked every fcfIsdnBriInterfaceCheckPeriod milliseconds and when it changes and remains changed after fcfIsdnBriFilterRepeatCount checkings, this new state is delivered to the upper level. This is a decimal integer in the range 0 to 51000 by step of 200. The default value is '200'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..51000  

fcfIsdnBriFilterRepeatCount 2.1.866.20.1.10.5.1.1.5
The value of this object indicates the number of detections of power source 1 or power source 2, whichever may be provided for this basic rate interface. The power source is checked every fcfIsdnBriInterfaceCheckPeriod milliseconds and when it changes and remains changed after fcfIsdnBriFilterRepeatCount checkings, this new state is delivered to the upper level. This is a decimal integer in the range 0 to 255. The default value is '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fcfIsdnBriEnablingTimer 2.1.866.20.1.10.5.1.1.6
The value of this object is the activation timer in milliseconds for this basic rate interface (timer 3). The deactivation function is specified in order to permit this interface and the network-side interface to be placed in a low power consumption mode when no calls are in progress. This timer starts upon the reception of an ACTIVATE REQUEST by the layer 1 and it is normally stopped when the ACTIVATED state is reached. The equipment sends DEACTIVATE INDICATIONS when this timer runs out This is a decimal integer in the range 200 to 30000 by step of 200. The default value is '10000'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 200..30000  

fcfIsdnBriDisablingTimer 2.1.866.20.1.10.5.1.1.7
The value of this object is the deactivation delay in milliseconds for this basic rate interface. The deactivation function is specified in order to permit this interface and the network-side interface to be placed in a low power consumption mode when no calls are in progress. The layer 2 is informed of the reception of an DEACTIVATE INDICATION by the layer 1 when this delay runs out. This is a decimal integer in the range 0 to 1000 by step of 200. The default value is '600'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1000  

fcfIsdnPrimaryRateInterfaceTable 2.1.866.20.1.10.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfIsdnPrimaryRateInterfaceEntry

fcfIsdnPrimaryRateInterfaceEntry 2.1.866.20.1.10.5.2.1
An entry of fcfIsdnPrimaryRateInterfaceTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfIsdnPrimaryRateInterfaceEntry  

fcfIsdnPrimaryRateInterfaceId 2.1.866.20.1.10.5.2.1.1
The value of this object identifies one and only one integrated services digital network (ISDN) primary rate interface (PRI). Each ISDN PRI corresponds, in fcfPhysicalPortTable, to one instance of fcfInterfaceType equal to 'isdnPri'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfIsdnPriSignalling 2.1.866.20.1.10.5.2.1.2
The value of this object indicates, for this primary rate interface, whether signalling is enabled or not. It must be set to 'on' to use the B-channels. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfIsdnPriCountry 2.1.866.20.1.10.5.2.1.3
The value of this object permits to take into account the national characteristics of some ISDN implementations : franceVn2 : France VN 2 implementation, franceVn3 : France VN 3 implementation, franceVn4 : France VN 4 implementation, unitedKingdom : France VN 2 implementation, switzerland : Switzerland implementation, europeanIsdn : Europe implementation. japan : japan implementation. usa : usa implementation. The default value is 'europeanIsdn'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER franceVn2(1), franceVn3(2), unitedKingdom(3), switzerland(4), europeanIsdn(5)  

fcfIsdnPriINbBChannel 2.1.866.20.1.10.5.2.1.10
The value of this object is the number of B channels for this ISDN primary rate interface. This is a decimal integer in the range 0 to 30 by step of 1. The default value is '30'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..30  

fcfIsdnPriCrc4 2.1.866.20.1.10.5.2.1.11
The value of this object indicates, for this primary rate interface, whether cyclic redundancy code management is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfIsdnDChannelSignallingTable 2.1.866.20.1.10.5.10
This table defines the signalling characteristics of the integrated services digital network (ISDN) basic rate interfaces (BRI). It is not possible to add or delete an entry of this table (each entry corresponds, in fcfIsdnBasicRateInterfaceTable, to one instance of fcfIsdnBriSignalling equal to 'on').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfIsdnDChannelSignallingEntry

fcfIsdnDChannelSignallingEntry 2.1.866.20.1.10.5.10.1
An entry of fcfIsdnDChannelSignallingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfIsdnDChannelSignallingEntry  

fcfIsdnDSigIsdnInterfaceId 2.1.866.20.1.10.5.10.1.1
The value of this object identifies one and only one integrated services digital network (ISDN) basic rate interface (BRI) with signalling procedures. Each ISDN BRI corresponds, in fcfIsdnBasicRateInterfaceTable, to one instance of fcfIsdnBriSignalling equal to 'on'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfIsdnDSigIsdnNumber 2.1.866.20.1.10.5.10.1.2
The value of this object indicates the ISDN address (the ISDN number and the optional subaddress) of this basic rate interface. This is a eleven-bytes octet string with : up to 16 digits in the range 0 to 9 for the ISDN number, an optional separator marking the end of the ISDN number and the beginning of the ISDN subaddress : digit 'A' (':' on the equipment configurator), optional 1 to 4 digits in the range 0 to 9 for the ISDN subaddress, mandatory 'F' digits to pad the value until a total of 22 digits (the equipment configurator does not need this final padding). The default value is 'FF FF FF FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(11)  

fcfIsdnDSigUnuseTimer 2.1.866.20.1.10.5.10.1.3
The value of this object is the unuse timer in seconds for this basic rate interface. This function is specified in order to clear a call when no communications are established on it. This timer starts upon the clearing of the last communication using this call and it is normally stopped when a new one is initiated. The equipment clears the call when this timer runs out. The value '0' disables the processing of this timer. This is a decimal integer in the range 0 to 2550 by step of 10. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2550  

fcfIsdnDSigCalledSubAddressCheck 2.1.866.20.1.10.5.10.1.4
The value of this object indicates, for this basic rate interface, whether ISDN subaddresses are checked or not. When it is set to 'on' the incoming calls are cleared if the called party subaddress is not present in the SETUP message. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfIsdnDSigDirectInwardDialingCheck 2.1.866.20.1.10.5.10.1.5
The value of this object indicates, for this basic rate interface, whether the direct dialling-in (DDI) service is used or not. When the direct dialling-in is in use, this basic rate interface accepts only the incoming calls with the called party number equal to its own ISDN number defined by fcfIsdnDSigIsdnNumber (the ISDN subaddress is not concerned). The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcfIsdnDSigInactivityTimer 2.1.866.20.1.10.5.10.1.6
The value of this object is the inactivity timer in seconds for this basic rate interface. This timer starts upon the establishment of the call and it restarts at each expiry if no trafic has been using it during this period.. The value '0' disables the processing of this timer. This is a decimal integer in the range 0 to 120. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..120  

fcfIsdnDSigMulDialsRetryTimer 2.1.866.20.1.10.5.10.1.10
The value of this object is the retry timer in seconds for this basic rate interface. To reach a particular destination the equipment may successively try one or several times to call one remote ISDN interfaces. This timer starts when a call is initiated towards a particular remote ISDN interface and it is normally stopped when this call is successfull. A new call towards this remote ISDN interface is initated when this timer runs out. This is a decimal integer in the range 1 to 254. The default value is '5'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fcfIsdnDSigMulDialsCycleTimer 2.1.866.20.1.10.5.10.1.11
The value of this object is the cycle timer in seconds for this basic rate interface. To reach a particular destination the equipment may successively try one or several times to call one or several remote ISDN interfaces. This is a cycle of calls and there may be several identical cycles. The cycle timer starts when a cycle of calls is initiated and it is normally stopped when one call is successfull. A new cycle of calls is initated when this timer runs out. This is a decimal integer in the range 1 to 254. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fcfIsdnDSigMulDialsCycleCount 2.1.866.20.1.10.5.10.1.12
The value of this object is the maximum number of cycle of calls for this basic rate interface. To reach a particular destination the equipment may successively try one or several times to call one or several remote ISDN interfaces. This is a cycle of calls and there may be several identical cycles. This is a decimal integer in the range 1 to 255. The default value is '3'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcfIsdnDSigMulDialsTotalDuration 2.1.866.20.1.10.5.10.1.13
The value of this object is, for this basic rate interface, the maximum duration in seconds of successive tries to reach a destination. To reach a particular destination the equipment may successively try one or several times to call one or several remote ISDN interfaces. This is a cycle of calls and there may be several identical cycles. This timer starts when the first cycle of calls is initiated and it is normally stopped when one call is successfull. If this timer runs out the destination is said unreachable. This is a decimal integer in the range 5 to 100. The default value is '100'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..100  

fcfIsdnDSigLowLayerCompatibility 2.1.866.20.1.10.5.10.1.20
The value of this object indicates whether the low layer compatibility information element (LLC IE) is present or not in the CONNECT and SETUP call establishment messages sent from this basic rate interface (outgoing call) and whether it is checked or not in the same messages received by this basic rate interface (incoming call). The checking of LLC IE in the incoming calls is made as described below : the coding standard must be set to 'CCITT standardized coding', the information transfer capability must be set to 'unrestricted digital information', the transfer mode must be set to 'circuit mode', the information transfer rate must be set to '64 kbit/s', the user information layer 1 protocol must be set to 'CCITT standardized rate adaption X.31 HDLC flag stuffing', the user information layer 2 protocol must be set to 'CCITT Recommendation X.25 link layer' or 'CCITT Recommendation X.25 multilink', the user information layer 3 protocol must be set to 'CCITT Recommendation X.25 packet layer', the other octets of the LLC IE are not checked, This object may be set to one of the following values : notTransmittedAndNotChecked : the LLC IE is not present in the outgoing calls and it is not checked in the incoming calls, transmittedAndNotChecked : the LLC IE is present in the outgoing calls and it is not checked in the incoming calls, notTransmittedAndChecked : the LLC IE is not present in the outgoing calls and it is checked in the incoming calls, transmittedAndChecked : the LLC IE is present in the outgoing calls and it is checked in the incoming calls. The default value is 'notTransmittedAndChecked'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notTransmittedAndNotChecked(1), transmittedAndNotChecked(2), notTransmittedAndChecked(3), transmittedAndChecked(4)  

fcfIsdnDSigHighLayerCompatibility 2.1.866.20.1.10.5.10.1.21
The value of this object indicates whether the high layer compatibility information element (HLC IE) is present or not in the SETUP call establishment messages sent from this basic rate interface (outgoing call) and whether it is checked or not in the same messages received by this basic rate interface (incoming call). The checking of HLC IE in the incoming calls consists in verifying that the HLC IE is equal to the value of fcfIsdnDSigHighLayerCharactIdent. This object may be set to one of the following values : notTransmittedAndNotChecked : the HLC IE is not present in the outgoing calls and it is not checked in the incoming calls, transmittedAndNotChecked : the HLC IE is present in the outgoing calls and it is not checked in the incoming calls, notTransmittedAndChecked : the HLC IE is not present in the outgoing calls and it is checked in the incoming calls, transmittedAndChecked : the HLC IE is present in the outgoing calls and it is checked in the incoming calls. The default value is 'notTransmittedAndChecked'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notTransmittedAndNotChecked(1), transmittedAndNotChecked(2), notTransmittedAndChecked(3), transmittedAndChecked(4)  

fcfIsdnDSigHighLayerCharactIdent 2.1.866.20.1.10.5.10.1.22
The value of this object indicates the value of the high layer compatibility information element (HLC IE) which must be present in the SETUP call establishment messages received by this basic rate interface (incoming call) when the checking is enabled (see fcfIsdnDSigHighLayerCompatibility) : ccittOsiApplication : the coding standard must be set to 'CCITT standardized coding', the interpretation must be set to 'first (primary only) high layer characteristics identification to be used in the call', the presentation method of protocol profile must be set to 'high layer protocol profile (without specification of attributes)', the high layer characteristics identification must be set to 'OSI application (recommendation X.200 series)', nationalUnknownNetworkedService : the coding standard must be set to 'national standard (only when the desired HLC cannot be represented with the CCITT-standardized coding)', the interpretation must be set to 'first (primary only) high layer characteristics identification to be used in the call', the presentation method of protocol profile must be set to 'high layer protocol profile (without specification of attributes)', the high layer characteristics identification must be set to 'unknown networked service', nationalNotStandardizedApplication : the coding standard must be set to 'national standard (only when the desired HLC cannot be represented with the CCITT-standardized coding)', the interpretation must be set to 'first (primary only) high layer characteristics identification to be used in the call', the presentation method of protocol profile must be set to 'high layer protocol profile (without specification of attributes)', the high layer characteristics identification must be set to 'not standardized application', The default value is 'notTransmittedAndChecked'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ccittOsiApplication(193), nationalUnknownNetworkedService(128), nationalNotStandardizedApplication(255)  

fcfIsdnDChannelSigTimerTable 2.1.866.20.1.10.5.11
This table defines the signalling timers of the integrated services digital network (ISDN) basic rate interfaces (BRI). It is not possible to add or delete an entry of this table (each entry corresponds, in fcfIsdnBasicRateInterfaceTable, to one instance of fcfIsdnBriSignalling equal to 'on').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfIsdnDChannelSigTimerEntry

fcfIsdnDChannelSigTimerEntry 2.1.866.20.1.10.5.11.1
An entry of fcfIsdnDChannelSigTimerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfIsdnDChannelSigTimerEntry  

fcfIsdnDTimIsdnInterfaceId 2.1.866.20.1.10.5.11.1.1
The value of this object identifies one and only one integrated services digital network (ISDN) basic rate interface (BRI) with signalling procedures. Each ISDN BRI corresponds, in fcfIsdnBasicRateInterfaceTable, to one instance of fcfIsdnBriSignalling equal to 'on'. This is a decimal integer in the range 0 to 35.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfIsdnDTimBChannelUpTimer 2.1.866.20.1.10.5.11.1.2
The value of this object is the up state timer in seconds for this basic rate interface. This timer starts when the ISDN call is successfull (i.e., a B-channel is established) and it is normally stopped when the protocol stack layered on this B-channel is in the up state. The call is cleared when this timer runs out. This is a decimal integer in the range 1 to 2550 by step of 10. The default value is '60'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2550  

fcfIsdnDTimT301AlertConnectTimer 2.1.866.20.1.10.5.11.1.10
The value of this object is the T301 timer in seconds for this basic rate interface. This timer starts when an ALERTING call establishment message is received and it is normally stopped when a CONNECT message is received. The call is cleared when this timer runs out. This is a decimal integer in the range 1 to 2550 by step of 10. The default value is '20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2550  

fcfIsdnDTimT303SetupResponseTimer 2.1.866.20.1.10.5.11.1.11
The value of this object is the T303 timer in seconds for this basic rate interface. This timer starts when a SETUP call establishment message is sent and it is normally stopped when an ALERTING, CONNECT, SETUP ACKNOWLEDGE, CALL PROCEEDING or RELEASE COMPLETE message is received. When this timer runs out for the first time the equipment retransmits the SETUP message and restarts this timer. When this timer runs out for the second time the equipment clears the call. This is a decimal integer in the range 1 to 255. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcfIsdnDTimT305DisconnectResponseTimer 2.1.866.20.1.10.5.11.1.12
The value of this object is the T305 timer in seconds for this basic rate interface. This timer starts when a DISCONNECT call clearing message is sent and it is normally stopped when a RELEASE or DISCONNECT message is received. When this timer runs out the equipment sent a RELEASE message. This is a decimal integer in the range 1 to 255. The default value is '30'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcfIsdnDTimT308ReleaseResponseTimer 2.1.866.20.1.10.5.11.1.13
The value of this object is the T308 timer in seconds for this basic rate interface. This timer starts when a RELEASE call clearing message is sent and it is normally stopped when a RELEASE COMPLETE or RELEASE message is received. When this timer runs out for the first time the equipment retransmits the RELEASE message and restarts this timer. When this timer runs out for the second time the equipment places the B-channel in maintenance condition. This is a decimal integer in the range 1 to 255. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcfIsdnDTimT309DataLinkFailureTimer 2.1.866.20.1.10.5.11.1.14
The value of this object is the T309 timer in seconds for this basic rate interface. This timer starts when the data link is disconnected and it is normally stopped when it is reconnected. The call is cleared when this timer runs out. This is a decimal integer in the range 0 to 180. The default value is '60'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..180  

fcfIsdnDTimT310CallProceedingTimer 2.1.866.20.1.10.5.11.1.15
The value of this object is the T310 timer in seconds for this basic rate interface. This timer starts when a CALL PROCEEDING call establishment message is received and it is normally stopped when an ALERTING, CONNECT, DISCONNECT or PROGRESS message is received. The DISCONNECT message is sent when this timer runs out. This is a decimal integer in the range 1 to 255. The default value is '40'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcfIsdnDTimT313ConnectAcknowledgeTimer 2.1.866.20.1.10.5.11.1.16
The value of this object is the T313 timer in seconds for this basic rate interface. This timer starts when a CONNECT call establishment message is sent and it is normally stopped when a CONNECT ACKNOWLEDGE message is received. The DISCONNECT message is sent when this timer runs out. This is a decimal integer in the range 1 to 255. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcfIsdnRemotePeerTable 2.1.866.20.1.10.5.20
This table contains the interfaces which may be connected to the equipment through an ISDN. Each of these remote ISDN interfaces is identified by a decimal integer in the range 0 to 249. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fcfIsdnRemStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfIsdnRemotePeerEntry

fcfIsdnRemotePeerEntry 2.1.866.20.1.10.5.20.1
An entry of fcfIsdnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfIsdnRemotePeerEntry  

fcfIsdnRemRemotePeerId 2.1.866.20.1.10.5.20.1.1
The value of this object identifies one and only one remote ISDN interface which may be connected to the equipment through an ISDN. This is a decimal integer in the range 0 to 249 in releases before 4.2, in the range 0 to 999 after.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

fcfIsdnRemStatus 2.1.866.20.1.10.5.20.1.2
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcfIsdnRemIsdnNumber 2.1.866.20.1.10.5.20.1.3
The value of this object is the ISDN address (the ISDN number and the optional subaddress) of this remote ISDN interface. This is a eleven-bytes octet string with : up to 16 digits in the range 0 to 9 for the ISDN number, an optional separator marking the end of the ISDN number and the beginning of the ISDN subaddress : digit 'A' (':' on the equipment configurator), optional 1 to 4 digits in the range 0 to 9 for the ISDN subaddress, mandatory 'F' digits to pad the value until a total of 22 digits (the equipment configurator does not need this final padding). This value is automatically completed by a selection of digits from the X121 address when this X121 address contains two digits 'A' (':' on the equipment configurator) to make the complete ISDN address. See, in the fcLogicalPorts group, the tables which defines the connections to the ISDN remote interfaces. The default value is 'FF FF FF FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(11)  

fcfIsdnRemCallDirection 2.1.866.20.1.10.5.20.1.4
The value of this object defines the mode used to establish the call with this remote ISDN interface : calling : the caller is one of the ISDN interface of the equipment, called : the caller is this remote ISDN interface, auto : automatic choise between 'calling' and 'called'. The default value is 'auto'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER calling(32), called(16), auto(48)  

fcfE1Ds1 2.1.866.20.1.10.15
OBJECT IDENTIFIER    

fcfE1Ds1PhysTable 2.1.866.20.1.10.15.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfE1Ds1PhysEntry

fcfE1Ds1PhysEntry 2.1.866.20.1.10.15.1.1
An entry of fcfE1Ds1PhysTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfE1Ds1PhysEntry  

fcfE1Ds1PhysIfId 2.1.866.20.1.10.15.1.1.1
IF E1 ou DS1 Physique id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfE1Ds1PhysStatus 2.1.866.20.1.10.15.1.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcfE1Ds1PhysPhysicalPort 2.1.866.20.1.10.15.1.1.3
PP E1 ou DS1
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fcfE1PhysPortTable 2.1.866.20.1.10.15.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfE1PhysPortEntry

fcfE1PhysPortEntry 2.1.866.20.1.10.15.3.1
An entry of fcfE1PhysPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfE1PhysPortEntry  

fcfE1PhysPortId 2.1.866.20.1.10.15.3.1.1
PP E1 If id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfE1PhysPortSynchSrc 2.1.866.20.1.10.15.3.1.2
Synchronisation Source
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER network(1), freeRun(2)  

fcfE1PhysPortFraming 2.1.866.20.1.10.15.3.1.3
Framing
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER doubleframe(1), multiframeWithCrc4(2), extendedCrc4(3)  

fcfE1PhysPortFlowType 2.1.866.20.1.10.15.3.1.4
Type de flux
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER data(1), voice(2), voiceAndData(3)  

fcfE1Ds1ChannelTable 2.1.866.20.1.10.15.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfE1Ds1ChannelEntry

fcfE1Ds1ChannelEntry 2.1.866.20.1.10.15.5.1
An entry of fcfE1Ds1ChannelTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfE1Ds1ChannelEntry  

fcfE1Ds1ChannelIfId 2.1.866.20.1.10.15.5.1.1
IF E1 ou DS1 Canal id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 42..181  

fcfE1Ds1ChannelStatus 2.1.866.20.1.10.15.5.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcfE1Ds1ChannelPhysIf 2.1.866.20.1.10.15.5.1.3
Interface E1 ou DS1 Physique
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fcfE1Ds1ChannelSlots 2.1.866.20.1.10.15.5.1.4
Slots
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..24)  

fcfE1Ds1DropInsertTable 2.1.866.20.1.10.15.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfE1Ds1DropInsertEntry

fcfE1Ds1DropInsertEntry 2.1.866.20.1.10.15.10.1
An entry of fcfE1Ds1DropInsertTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfE1Ds1DropInsertEntry  

fcfE1Ds1DropInsertIf1 2.1.866.20.1.10.15.10.1.1
Interface Canal 1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 42..181  

fcfE1Ds1DropInsertIf2 2.1.866.20.1.10.15.10.1.2
Interface Canal 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 42..181  

fcfE1Ds1DropInsertStatus 2.1.866.20.1.10.15.10.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcfTokenRing 2.1.866.20.1.10.20
OBJECT IDENTIFIER    

fcfTokenRingTable 2.1.866.20.1.10.20.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcfTokenRingEntry

fcfTokenRingEntry 2.1.866.20.1.10.20.1.1
An entry of fcfTokenRingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcfTokenRingEntry  

fcfTokenRingInterfaceId 2.1.866.20.1.10.20.1.1.1
IF id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcfTokenRingSpeed 2.1.866.20.1.10.20.1.1.2
Vitesse
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s4000000(1), s16000000(2)  

fcfTokenRingLinkCheckPeriod 2.1.866.20.1.10.20.1.1.3
Periode de surveillance jonction (msec)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcfTokenRingCheckPeriodCount 2.1.866.20.1.10.20.1.1.4
Confirmation au bout de n periodes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..250  

fcFrameRelaySwitch 2.1.866.20.1.15
OBJECT IDENTIFIER    

fcFrSwitchingTable 2.1.866.20.1.15.1
This table defines the static part of ralaying table used by the frame relay switch to establish bi-directional connections between PVC (Permanenent Virtual Circuit) end points. A PVC end point is defined by the couple (interface identifier, data link connection identifier).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcFrSwitchingEntry

fcFrSwitchingEntry 2.1.866.20.1.15.1.1
An entry of fcFrSwitchingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcFrSwitchingEntry  

fcFrSwInputInterfaceId 2.1.866.20.1.15.1.1.1
The value of this object is the interface identifier for this PVC end point. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fcFrSwInputDlci 2.1.866.20.1.15.1.1.2
The value of this object is the Data Link Connection Identifier for this PVC end point. The possible values are : '0..1023. If it is unused, the value of this parameter is '65535'. The PVC end point connected to this PVC end point is defined by fcFrSwOutputInterfaceId and fcFrSwOutputDlci.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..991  

fcFrSwStatus 2.1.866.20.1.15.1.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcFrSwOutputInterfaceId 2.1.866.20.1.15.1.1.4
The value of this object is the interface identifier for the connected PVC end point. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fcFrSwOutputDlci 2.1.866.20.1.15.1.1.5
The value of this object is the Data Link Connection Identifier for the connected PVC end point. The possible values are : '0..1023. If it is unused, the value of this parameter is '65535'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..991  

fcFrSwPriority 2.1.866.20.1.15.1.1.6
The value of this object indicates if this PVC end point connection is foreground. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcLogicalPorts 2.1.866.20.1.20
OBJECT IDENTIFIER    

fclLogicalPortTable 2.1.866.20.1.20.1
This table defines the parameters of a logical port. A logical port permits the transmission between systems with a specific stack of protocols, over one physical port or more.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclLogicalPortEntry

fclLogicalPortEntry 2.1.866.20.1.20.1.1
An entry of fclLogicalPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclLogicalPortEntry  

fclLogPortId 2.1.866.20.1.20.1.1.1
The value of this object identifies one and only one logical port. The possible values are : '0..131. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclLogPortStatus 2.1.866.20.1.20.1.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclLogPortType 2.1.866.20.1.20.1.1.3
The value of this object identifies the stack of protocols used by this logical port. The default value is 'x25InterNode'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ethernet-tr(1), asynchronous(10), fra(11), hdlc(12), sdlc(13), vip(14), bsc3270(15), bsc2780or3780(16), bscSCT(17), x25Access(20), x25InDIsdn(21), x25InBIsdn(22), x25InPstn(23), x25InterNode(24), x25Mlp(25), pppSerialLink(30), pppPstn(31), pppIsdn(32), frCe(40), frTe(41), frSe(42), frSeInBIsdn(45), interUnitLink(50)  

fclEthernet 2.1.866.20.1.20.2
OBJECT IDENTIFIER    

fclEthernetTable 2.1.866.20.1.20.2.1
This table defines the parameters of an ethernet logical port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclEthernetEntry

fclEthernetEntry 2.1.866.20.1.20.2.1.1
An entry of fclEthernetTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclEthernetEntry  

fclEthLogPortId 2.1.866.20.1.20.2.1.1.1
The value of this object identifies one and only one ethernet logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclEthInterfaceId 2.1.866.20.1.20.2.1.1.2
The value of this object identifies the ethernet interface used by this logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclAsynchronousAccessLogPort 2.1.866.20.1.20.5
OBJECT IDENTIFIER    

fclAsynLogPortTable 2.1.866.20.1.20.5.1
This table defines the general parameters of asynchronous logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynLogPortEntry

fclAsynLogPortEntry 2.1.866.20.1.20.5.1.1
An entry of fclAsynLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynLogPortEntry  

fclAsynLpLogPortId 2.1.866.20.1.20.5.1.1.1
The value of this object identifies one and only one asynchronous logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclAsynLpInterfaceId 2.1.866.20.1.20.5.1.1.2
The value of this object identifies the line interface used by this asynchronous logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclAsynLpSubscriberNumber 2.1.866.20.1.20.5.1.1.3
The value of this object is the SB number added to the DNICZO of the equipment to make the calling address in a call sent from this logical port. The value must contain 2 digits (digits 0..9). The default value is 'FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclAsynLpConfigId 2.1.866.20.1.20.5.1.1.4
The value of this object identifies the asynchronous configuration used by this asynchronous logical port. This asynchronous configuration must be present in fclAsynCfgConfigTable. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynLpTerminalType 2.1.866.20.1.20.5.1.1.5
The value of this object is the type of the terminal connected to this asynchronous logical port. The default value is 'pad'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pad(1), videotext(2), lowSpeedComputerPort(3), lowSpeedComputerPortWithAutoCalls(4), kioskClient(7), multiStandardPad(6), x28Plus(20)  

fclAsynPadLogPort 2.1.866.20.1.20.5.2
OBJECT IDENTIFIER    

fclAsynPadLpTable 2.1.866.20.1.20.5.2.1
This table defines the specific parameters of an asynchronous logical port when the terminal type is 'pad'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynPadLpEntry

fclAsynPadLpEntry 2.1.866.20.1.20.5.2.1.1
An entry of fclAsynPadLpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynPadLpEntry  

fclAsynPadLpLogPortId 2.1.866.20.1.20.5.2.1.1.1
The value of this object identifies one and only one asynchronous logical port used to connect a 'pad' terminal. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  


fclAsynPadLpSpeedDetection 2.1.866.20.1.20.5.2.1.1.3
The value of this object indicates if the automatic speed detection is used. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynPadLpEquipment 2.1.866.20.1.20.5.2.1.1.4
The value of this object indicates the terminal in facing. 'other' means 'all equipment except Hewlett Packard'. The default value is 'other'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), hpHost(2), hpTerminal(3)  

fclAsynPadLpMnemonicType 2.1.866.20.1.20.5.2.1.1.5
The value of this object indicates the mnemonic type. When set to 'pad' the mnemonic must begin with a point, the call command is allowed, the X28 command is allowed, the call data and the password are checked by the remote host. When set to 'vdxRemoteAuth' the mnemonic may optionaly begin with a point, the call command is forbidden, the X28 command is forbidden, the call data and the password are checked by the remote host. When set to 'vdxTeletel' the mnemonic may optionaly begin with a point, the call command is allowed, the X28 command is forbidden, the call data and the password are checked by the remote host. When set to 'vdxLocalAuth' the mnemonic may optionaly begin with a point, the call command is forbidden, the X28 command is forbidden, the call data and the password are checked by the pad. The default is 'pad'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pad(1), vdxRemoteAuth(2), vdxTeletel(3), vdxLocalAuth(4)  

fclAsynPadLpNui 2.1.866.20.1.20.5.2.1.1.6
The value of this object indicates the treatment of the NUI (Network User Identifier). The authorized values are 'none' (not checking), 'none-rc' (not checking, but reverse charging), 'optional-transmitOrRc' (The NUI is optional. If it is present, the NUI is transmitted, else reverse charging), 'optional-checkNuaOrRc' (The NUI is optional, if the NUI is present then it is checked else reverse charging), 'mandatory-check' (The NUI is mandatory and checked), 'mandatory-check-nua' (The NUI is mandatory and checked. After checking, the NUI is coded in NUA), 'mandatory-transmit' (The NUI is mandatory but not checked, and it is transmitted), 'command-transmitOrRc' (NUI ON or NUI OFF is manadatory before a communication). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), none-rc(7), optional-transmitOrRc(6), optional-checkNuaOrRc(4), mandatory-check(2), mandatory-check-nua(3), mandatory-transmit(5), command-transmitOrRc(11)  

fclAsynPadLpCombinedFlowCtrl 2.1.866.20.1.20.5.2.1.1.7
The value of this object indicates wheter combined flow control (by XON/XOFF and RTS/CTS) is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynPadHomePageTable 2.1.866.20.1.20.5.2.10
This table defines the home page of the PAD. The home page is made of blocks. Each block contains a message and its graphical attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynPadHomePageEntry

fclAsynPadHomePageEntry 2.1.866.20.1.20.5.2.10.1
An entry of fclAsynPadHomePageTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynPadHomePageEntry  

fclAsynPadPageBlocId 2.1.866.20.1.20.5.2.10.1.1
The value of this object is the block identifier. The possible values are '0..99'. If it is unused, the value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..19  

fclAsynPadPageStatus 2.1.866.20.1.20.5.2.10.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclAsynPadPageMessage 2.1.866.20.1.20.5.2.10.1.3
The value of this object is the message. This message may contains from 0 to 12 characters. The default value is the empty string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..12)  

fclAsynPadPageAttributes 2.1.866.20.1.20.5.2.10.1.4
The value of this object defines the attributes used to display the message. 11 bytes from 00 to FF must be specified. The first byte contains the number of following useful bytes. The trailing bytes must be set to 'FF'. The equipment configurator does not need this final completion. The default value is 'empty' (first byte set to '00').
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(11)  

fclAsynVdxLogPort 2.1.866.20.1.20.5.3
OBJECT IDENTIFIER    

fclAsynVdxLpTable 2.1.866.20.1.20.5.3.1
This table defines the specific parameters of an asynchronous logical port when the terminal type is 'videotext'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynVdxLpEntry

fclAsynVdxLpEntry 2.1.866.20.1.20.5.3.1.1
An entry of fclAsynVdxLpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynVdxLpEntry  

fclAsynVdxLpLogPortId 2.1.866.20.1.20.5.3.1.1.1
The value of this object identifies one and only one asynchronous logical port used to connect a 'videotext' terminal. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  


fclAsynVdxLpMnemonicType 2.1.866.20.1.20.5.3.1.1.5
The value of this object indicates the mnemonic type. When set to 'pad' the mnemonic must begin with a point, the call command is allowed, the X28 command is allowed, the call data and the password are checked by the remote host. When set to 'vdxRemoteAuth' the mnemonic may optionaly begin with a point, the call command is forbidden, the X28 command is forbidden, the call data and the password are checked by the remote host. When set to 'vdxTeletel' the mnemonic may optionaly begin with a point, the call command is allowed, the X28 command is forbidden, the call data and the password are checked by the remote host. When set to 'vdxLocalAuth' the mnemonic may optionaly begin with a point, the call command is forbidden, the X28 command is forbidden, the call data and the password are checked by the pad. The default is 'pad'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pad(1), vdxRemoteAuth(2), vdxTeletel(3), vdxLocalAuth(4)  

fclAsynVdxLpNui 2.1.866.20.1.20.5.3.1.1.6
The value of this object indicates the treatment of the NUI (Network User Identifier). The authorized values are 'none' (not checking), 'none-rc' (not checking, but reverse charging), 'optional-transmitOrRc' (The NUI is optional. If it is present, the NUI is transmitted, else reverse charging), 'optional-checkNuaOrRc' (The NUI is optional, if the NUI is present then it is checked else reverse charging), 'mandatory-check' (The NUI is mandatory and checked), 'mandatory-check-nua' (The NUI is mandatory and checked. After checking, the NUI is coded in NUA), 'mandatory-transmit' (The NUI is mandatory but not checked, and it is transmitted), 'command-transmitOrRc' (NUI ON or NUI OFF is manadatory before a communication). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), none-rc(7), optional-transmitOrRc(6), optional-checkNuaOrRc(4), mandatory-check(2), mandatory-check-nua(3), mandatory-transmit(5), command-transmitOrRc(11)  

fclAsynVdxLpParityBit 2.1.866.20.1.20.5.3.1.1.10
Parite X25
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), setTo1(2)  

fclAsynVdxLpPceSubThreshold 2.1.866.20.1.20.5.3.1.1.11
Seuil de Comptage SUB (PCE)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fclAsynVdxLpPceNackTimer 2.1.866.20.1.20.5.3.1.1.12
Tempo d'emission NACK (PCE) msec
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25400  

fclAsynVdxHomePageTable 2.1.866.20.1.20.5.3.10
This table defines the home page of the VIDEOTEXT PAD. The home page is made of blocks. Each block contains a message and its graphical attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynVdxHomePageEntry

fclAsynVdxHomePageEntry 2.1.866.20.1.20.5.3.10.1
An entry of fclAsynVdxHomePageTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynVdxHomePageEntry  

fclAsynVdxPageBlocId 2.1.866.20.1.20.5.3.10.1.1
The value of this object is the block identifier. The possible values are '0..99'. If it is unused, the value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

fclAsynVdxPageStatus 2.1.866.20.1.20.5.3.10.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclAsynVdxPageMessage 2.1.866.20.1.20.5.3.10.1.3
The value of this object is the message. This message may contains from 0 to 12 characters. The default value is the empty string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..12)  

fclAsynVdxPageAttributes 2.1.866.20.1.20.5.3.10.1.4
The value of this object defines the attributes used to display the message. 11 bytes from 00 to FF must be specified. The first byte contains the number of following useful bytes. The trailing bytes must be set to 'FF'. The equipment configurator does not need this final completion. The values are defined by the TELETEL standard. The default value is 'empty' (first byte set to '00').
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(11)  

fclAsynLowSpeedCpLogPort 2.1.866.20.1.20.5.4
OBJECT IDENTIFIER    

fclAsynLscpLpTable 2.1.866.20.1.20.5.4.1
This table defines the specific parameters of an asynchronous logical port when the terminal type is 'lowSpeedComputerPort' or 'lowSpeedComputerPortWithAutoCalls'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynLscpLpEntry

fclAsynLscpLpEntry 2.1.866.20.1.20.5.4.1.1
An entry of fclAsynLscpLpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynLscpLpEntry  

fclAsynLscpLpLogPortId 2.1.866.20.1.20.5.4.1.1.1
The value of this object identifies one and only one asynchronous logical port used to connect a 'lowSpeedComputerPort' terminal. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  


fclAsynLscpLpEquipment 2.1.866.20.1.20.5.4.1.1.4
The value of this object indicates the terminal in facing. 'other' means 'all equipment except Hewlett Packard'. The default value is 'other'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), hpHost(2), hpTerminal(3)  

fclAsynMultiStandardPadLogPort 2.1.866.20.1.20.5.5
OBJECT IDENTIFIER    

fclAsynMultiLpTable 2.1.866.20.1.20.5.5.1
This table defines the specific parameters of an asynchronous logical port when the terminal type is 'multiStandardPad'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynMultiLpEntry

fclAsynMultiLpEntry 2.1.866.20.1.20.5.5.1.1
An entry of fclAsynMultiLpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynMultiLpEntry  

fclAsynMultiLpLogPortId 2.1.866.20.1.20.5.5.1.1.1
The value of this object identifies one and only one asynchronous logical port used to connect a 'multiStandardPad' terminal. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclAsynMultiLpAuthStep1 2.1.866.20.1.20.5.5.1.1.10
The value of this object defines the treatment used in the first step of authentication. 'undefined' means 'no treatment. The default value is 'undefined'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER undefined(1), tfi-noParity(2), tfi-evenParity(3), enquire(4), ter(5)  

fclAsynMultiLpAuthStep2 2.1.866.20.1.20.5.5.1.1.11
The value of this object defines the treatment used in the second step of authentication. 'undefined' means 'no treatment. The default value is 'undefined'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER undefined(1), tfi-noParity(2), tfi-evenParity(3), enquire(4), ter(5)  

fclAsynMultiLpAuthStep3 2.1.866.20.1.20.5.5.1.1.12
The value of this object defines the treatment used in the third step of authentication. 'undefined' means 'no treatment. The default value is 'undefined'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER undefined(1), tfi-noParity(2), tfi-evenParity(3), enquire(4), ter(5)  

fclAsynMultiLpAuthStep4 2.1.866.20.1.20.5.5.1.1.13
The value of this object defines the treatment used in the fourth step of authentication. 'undefined' means 'no treatment. The default value is 'undefined'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER undefined(1), tfi-noParity(2), tfi-evenParity(3), enquire(4), ter(5)  

fclAsynX28PlusLogPort 2.1.866.20.1.20.5.6
OBJECT IDENTIFIER    

fclAsynX28PlusLpTable 2.1.866.20.1.20.5.6.1
This table defines the specific parameters of an asynchronous logical port when the terminal type is 'x28plus'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynX28PlusLpEntry

fclAsynX28PlusLpEntry 2.1.866.20.1.20.5.6.1.1
An entry of fclAsynX28PlusLpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynX28PlusLpEntry  

fclAsynX28PlusLpLogPortId 2.1.866.20.1.20.5.6.1.1.1
The value of this object identifies one and only one asynchronous logical port used to connect a 'x28plus' terminal. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  


fclAsynX28PlusLpSpeedDetection 2.1.866.20.1.20.5.6.1.1.3
The value of this object indicates if the automatic speed detection is used. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynX28PlusLpEquipment 2.1.866.20.1.20.5.6.1.1.4
The value of this object indicates the terminal in facing. 'other' means 'all equipment except Hewlett Packard'. The default value is 'other'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), hpHost(2), hpTerminal(3)  

fclAsynX28PlusLpMnemonicType 2.1.866.20.1.20.5.6.1.1.5
The value of this object indicates the mnemonic type. When set to 'pad' the mnemonic must begin with a point, the call command is allowed, the X28 command is allowed, the call data and the password are checked by the remote host. When set to 'vdxRemoteAuth' the mnemonic may optionaly begin with a point, the call command is forbidden, the X28 command is forbidden, the call data and the password are checked by the remote host. When set to 'vdxTeletel' the mnemonic may optionaly begin with a point, the call command is allowed, the X28 command is forbidden, the call data and the password are checked by the remote host. When set to 'vdxLocalAuth' the mnemonic may optionaly begin with a point, the call command is forbidden, the X28 command is forbidden, the call data and the password are checked by the pad. The default is 'pad'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pad(1), vdxRemoteAuth(2), vdxTeletel(3), vdxLocalAuth(4)  

fclAsynX28PlusLpFullDuplex 2.1.866.20.1.20.5.6.1.1.10
The value of this object indicates whether the line is in full duplex (with echo) or half duplex (without echo). The echo of a transfer mode character is also defined by the X3 parameter number 2. The authorized values are 'off' (line in half duplex), 'on' (line in full duplex). The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynX28PlusLpIdleTimerSelection 2.1.866.20.1.20.5.6.1.1.11
The value of this object indicates whether the timers fclAsynCfgX3P04IdleTimerDelay and fclAsynX28PlusLpIdleTimerDelay are enabled or not. The data are sent upon when one of these two timers expires. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynX28PlusLpIdleTimerDelay 2.1.866.20.1.20.5.6.1.1.12
The value of this object defines the data forwarding time-out in milliseconds. This timer is started at reception time of the first character. When this time-out expires, the PAD sends the received characters to the network. The time-out is restarted upon reception of the first character to follow. The authorized values are '0..12750' milliseconds. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..12750  

fclAsynX28PlusLpX3Mode 2.1.866.20.1.20.5.6.1.1.13
The value of this object indicates the X3 mode. The authorized value are 'transparent' (X3 parameters 1, 13 and 15 are interpreted : case of escape, no LF insertion after CR) or 'networkVirtualTerminal' (X3 parameters 1, 13 and 15 are not inhibited). The default value is 'networkVirtualTerminal'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER transparent(1), networkVirtualTerminal(2)  

fclAsynX28PlusLpEscapeDigit 2.1.866.20.1.20.5.6.1.1.14
Digit d'echappement
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9  

fclAsynX28PlusLpConIdTelenet 2.1.866.20.1.20.5.6.1.1.15
Config ID TELENET
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclAsynX28PlusLpConIdRemote 2.1.866.20.1.20.5.6.1.1.16
Config ID Remote X3 et TELENET
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclAsynX28PlusLpRemPrSentOnCalls 2.1.866.20.1.20.5.6.1.1.17
Envoi du profil distant
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER never(1), inBound(2), outBound(3), both(4)  

fclAsynX28PlusLpEasyMnemo 2.1.866.20.1.20.5.6.1.1.20
Facilite mnemonique
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynX28PlusLpMonSignalCTS 2.1.866.20.1.20.5.6.1.1.21
Gestion du signal sortant106CTS (DCE)/108DTR(DTE)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclAsynX28PlusLpMonSignalDSR 2.1.866.20.1.20.5.6.1.1.22
Gestion du signal sortant 107DSR (DCE)/111DRS(DTE)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclAsynX28PlusLpMonSignalDCD 2.1.866.20.1.20.5.6.1.1.23
Gestion du signal sortant 109DCD(DCE)/105RTS(DTE)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclAsynX28PlusGeneralParameters 2.1.866.20.1.20.5.6.2
OBJECT IDENTIFIER    

fclAsynX28PlusGenParDNIC 2.1.866.20.1.20.5.6.2.1
DNIC pour adresse abregee
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

fclAsynX28PlusConfTELENETTable 2.1.866.20.1.20.5.6.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynX28PlusConfTELENETEntry

fclAsynX28PlusConfTELENETEntry 2.1.866.20.1.20.5.6.3.1
An entry of fclAsynX28PlusConfTELENETTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynX28PlusConfTELENETEntry  

fclAsynX28PlusCfgTELENETConfigId 2.1.866.20.1.20.5.6.3.1.1
Config Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclAsynX28PlusCfgTELENETDescription 2.1.866.20.1.20.5.6.3.1.2
Description
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

fclAsynX28PlusParTELENETTable 2.1.866.20.1.20.5.6.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynX28PlusParTELENETEntry

fclAsynX28PlusParTELENETEntry 2.1.866.20.1.20.5.6.4.1
An entry of fclAsynX28PlusParTELENETTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynX28PlusParTELENETEntry  

fclAsynX28PlusParTelConfigId 2.1.866.20.1.20.5.6.4.1.1
Config Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclAsynX28PlusParTelLpFullDuplex 2.1.866.20.1.20.5.6.4.1.10
Ligne FullDuplex
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynX28PlusParTelLpIdleTimerSelection 2.1.866.20.1.20.5.6.4.1.11
Envoi sur tempo
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynX28PlusParTelLpIdleTimerDelay 2.1.866.20.1.20.5.6.4.1.12
Tempo d'envoi de donnees
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..12750  

fclAsynX28PlusParTelLpX3Mode 2.1.866.20.1.20.5.6.4.1.13
Terminal Virtuel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER transparent(1), networkVirtualTerminal(2)  

fclAsynX28PlusConfRemoteTable 2.1.866.20.1.20.5.6.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynX28PlusConfRemoteEntry

fclAsynX28PlusConfRemoteEntry 2.1.866.20.1.20.5.6.5.1
An entry of fclAsynX28PlusConfRemoteTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynX28PlusConfRemoteEntry  

fclAsynX28PlusRemoteConfigId 2.1.866.20.1.20.5.6.5.1.1
Config Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclAsynX28PlusRemoteCfgDescription 2.1.866.20.1.20.5.6.5.1.2
Description
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

fclAsynX28PlusRemoteCfgX3Part1Table 2.1.866.20.1.20.5.6.6
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynX28PlusRemoteCfgX3Part1Entry

fclAsynX28PlusRemoteCfgX3Part1Entry 2.1.866.20.1.20.5.6.6.1
An entry of fclAsynX28PlusRemoteCfgX3Part1Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynX28PlusRemoteCfgX3Part1Entry  

fclAsynX28PlusRemConfigId 2.1.866.20.1.20.5.6.6.1.1
Config Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynX28PlusRemCfgX3P01EscapeChar 2.1.866.20.1.20.5.6.6.1.11
Caractere d'echappement
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..126  

fclAsynX28PlusRemCfgX3P02Echo 2.1.866.20.1.20.5.6.6.1.12
Echo
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-off(1), val1-on(2), not-used(255)  

fclAsynX28PlusRemCfgX3P03ForwardingChar 2.1.866.20.1.20.5.6.6.1.13
Caractere d'envoi des donnees
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val2-cr(3), val6-crEscBelEnqAck(7), val18-crEotEtx(19), val32-htLfVtFf(33), val126-allCtrlChars(127), val127-allChars(128), val128-allCtrlChars-vdxFunctionKeys(129), val253-encapsCharacSLIP(254), not-used(255)  

fclAsynX28PlusRemCfgX3P04IdleTimerDelay 2.1.866.20.1.20.5.6.6.1.14
Delai d'envoi (en 1/20eme de seconde)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynX28PlusRemCfgX3P05OutputFlowCtrl 2.1.866.20.1.20.5.6.6.1.15
Control de flux PAD vers Terminal
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-xonXoffInTransfer(2), val2-xonXoff(3), val8-rtsCtsInTransfer(9), not-used(255)  

fclAsynX28PlusRemCfgX3P06ServiceSignals 2.1.866.20.1.20.5.6.6.1.16
Transmission des indications par le PAD
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-servSignal-stdFormat(2), val5-servSignalAndPrompt-stdFormat(6), val9-servSignal-explicitFormat(10), val13-servSignalAndPrompt-explicitFormat(14), not-used(255)  

fclAsynX28PlusRemCfgX3P07BreakHandling 2.1.866.20.1.20.5.6.6.1.17
Reaction sur Break
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-forwardingChar(1), val1-interrupt(2), val2-reset(3), val4-breakIndication(5), val5-interrupt-breakIndication(6), val8-escapeFromTransfer(9), val21-interrupt-breakIndication-discardOutput(22), not-used(255)  

fclAsynX28PlusRemCfgX3P08OutputDiscard 2.1.866.20.1.20.5.6.6.1.18
Arret de la remise des donnees
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-off(1), val1-on(2), not-used(255)  

fclAsynX28PlusRemCfgX3P09CrPadding 2.1.866.20.1.20.5.6.6.1.19
Bourrage apres RC
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynX28PlusRemCfgX3P10LineFolding 2.1.866.20.1.20.5.6.6.1.20
Pliage de ligne
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynX28PlusRemCfgX3P11BinarySpeed 2.1.866.20.1.20.5.6.6.1.21
Debit binaire (en bit/s)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-110(1), val1-134-5(2), val2-300(3), val3-1200(4), val4-600(5), val5-75(6), val6-150(7), val7-1800(8), val8-200(9), val9-100(10), val10-50(11), val11-in75Out1200(12), val12-2400(13), val13-4800(14), val14-9600(15), val15-19200(16), val23-28800(24), val17-57600(18), val20-38400(21), val21-out1200In75(22), val22-115200(23), not-used(255)  

fclAsynX28PlusRemoteCfgX3Part2Table 2.1.866.20.1.20.5.6.7
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynX28PlusRemoteCfgX3Part2Entry

fclAsynX28PlusRemoteCfgX3Part2Entry 2.1.866.20.1.20.5.6.7.1
An entry of fclAsynX28PlusRemoteCfgX3Part2Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynX28PlusRemoteCfgX3Part2Entry  

fclAsynX28PlusRemCfgX3Part2ConfigId 2.1.866.20.1.20.5.6.7.1.1
Config Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynX28PlusRemCfgX3P12InputFlowCtrl 2.1.866.20.1.20.5.6.7.1.22
Control de flux Terminal vers PAD
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-xonXoff(2), val8-rtsCts(9), not-used(255)  

fclAsynX28PlusRemCfgX3P13LfInsertion 2.1.866.20.1.20.5.6.7.1.23
Insertion de LF apres RC
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-outCr(2), val2-inCr(3), val3-outCr-inCr(4), val4-outCrEcho(5), val5-outCr-outCrEcho(6), val6-inCr-outCrEcho(7), val7-outCr-inCr-outCrEcho(8), not-used(255)  

fclAsynX28PlusRemCfgX3P14LfPadding 2.1.866.20.1.20.5.6.7.1.24
Bourrage apres LF
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynX28PlusRemCfgX3P15Editing 2.1.866.20.1.20.5.6.7.1.25
Edition
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-off(1), val1-on(2), not-used(255)  

fclAsynX28PlusRemCfgX3P16CharDelete 2.1.866.20.1.20.5.6.7.1.26
Caractere d'effacement d'un caractere
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

fclAsynX28PlusRemCfgX3P17LineDelete 2.1.866.20.1.20.5.6.7.1.27
Caractere d'effacement d'une ligne
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

fclAsynX28PlusRemCfgX3P18LineDisplay 2.1.866.20.1.20.5.6.7.1.28
Caractere d'affichage d'une ligne
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fclAsynX28PlusRemCfgX3P19EditingSignal 2.1.866.20.1.20.5.6.7.1.29
Indication d'edition
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-printingTerminal(2), val2-displayTerminal(3), not-used(255)  

fclAsynX28PlusRemCfgX3P20EchoMask 2.1.866.20.1.20.5.6.7.1.30
Masque d'echo
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fclAsynX28PlusRemCfgX3P21Parity 2.1.866.20.1.20.5.6.7.1.31
Traitement de la parite
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-check(2), val2-generate(3), val3-check-generate(4), not-used(255)  

fclAsynX28PlusRemCfgX3P22PageWait 2.1.866.20.1.20.5.6.7.1.32
Attente en fin de page
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fclAsynX28PlusRemoteTELENETTable 2.1.866.20.1.20.5.6.8
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynX28PlusRemoteTELENETEntry

fclAsynX28PlusRemoteTELENETEntry 2.1.866.20.1.20.5.6.8.1
An entry of fclAsynX28PlusRemoteTELENETTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynX28PlusRemoteTELENETEntry  

fclAsynX28PlusRemCfgTELENETConfigId 2.1.866.20.1.20.5.6.8.1.1
Config Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclAsynX28PlusRemLpFullDuplex 2.1.866.20.1.20.5.6.8.1.10
Ligne FullDuplex
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), not-used(255)  

fclAsynX28PlusRemLpIdleTimerSelection 2.1.866.20.1.20.5.6.8.1.11
Envoi sur tempo
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), not-used(255)  

fclAsynX28PlusRemLpIdleTimerDelay 2.1.866.20.1.20.5.6.8.1.12
Tempo d'envoi de donnees
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..12750  

fclAsynX28PlusRemLpX3Mode 2.1.866.20.1.20.5.6.8.1.13
Terminal Virtuel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER transparent(1), networkVirtualTerminal(2), not-used(255)  

fclAsynGeneralParameters 2.1.866.20.1.20.5.7
OBJECT IDENTIFIER    

fclAsynGenParLanguageType 2.1.866.20.1.20.5.7.1
Type de langue
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER french(1), english(2)  

fclAsynConfiguration 2.1.866.20.1.20.5.10
OBJECT IDENTIFIER    

fclAsynCfgConfigTable 2.1.866.20.1.20.5.10.1
This table contains the asynchronous configurations used in the asynchronous logical port table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynCfgConfigEntry

fclAsynCfgConfigEntry 2.1.866.20.1.20.5.10.1.1
An entry of fclAsynCfgConfigTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynCfgConfigEntry  

fclAsynCfgConfigId 2.1.866.20.1.20.5.10.1.1.1
The value of this object identifies one and only one asynchronous configuration. This configuration may be referenced by fclAsynLpConfigId in the asynchronous logical port table. The possible values are : '0..199. If it is unused, the value of this parameter is '255'. The configuration parameters are described in : fclAsynCfgX3Part1Table : X3 part 1, fclAsynCfgX3Part2Table : X3 part 2, fclAsynCfgConnLinkTable : data link level (connection part), fclAsynCfgConnFacilityTable : facility level (connection part), fclAsynCfgConnServiceTable : service level (connection part). When creating a new configuration each parameter takes its default value. Setting a profile allows the user to fill all the parameters with values pre-defined in this profile but each one may also be individually modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgStatus 2.1.866.20.1.20.5.10.1.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclAsynCfgDescription 2.1.866.20.1.20.5.10.1.1.3
The value of this object stores a text description of the configuration elaborated by the user. This description may contains from 0 to 32 characters. The default value is 'TTY'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

fclAsynCfgX3ProfileId 2.1.866.20.1.20.5.10.1.1.4
The value of this object is the profile number used to automatically valorize all the X3 parameters in an entry of the two tables which composes the X3 part of asynchronous configurations (see fclAsynCfgConfigId). The possible values are : 00 Plain terminal, 01 Transparent terminal or LSCP, 02 LSCP, 03 Terminal communicating with LSCP, 04 Same as profile 03 with send time-out and padding, 05 Terminal with control by PAD, 06 Same es profile 00 with special break and break, 08 Same as profile 05 with echo, 09 Telex terminals, 10 Same as profile 05 without control by PAD, 11 Same as profile 02 without control by PAD, 12 Same as profile 00 without echo, 13 Block mode terminal controlled by PAD without send time-out, 14 Same as profile 13 with authorized DLE, 15 Same as profile 13 without control, 16 Host HEWLETT PACKARD, 17 Terminal HEWLETT PACKARD, 20 Same as profile 00 with control and teleprinter adapted editing, 21 Same as profile 20 with display-terminal adapted editing, 22 Same as profile 13 with control bye DTE-C, 23 Same as profile 21 for data base application, 30 VIDEOTEX terminal, 32 Multi-standard VIDEOTEX terminal, 80 User defined profile : the values in this profile are defined by the user (they may be specified in groups fclAsynCfgX3UserProfilePart1 and fclAsynCfgX3UserProfilePart2, 89 Special terminal, 90 Plain terminal without padding or send time-out, 91 Plain transparent LSCP. If it is unused, the value of this parameter is '255'. The default value is '89' (meaning that default values of X3 parameters are those pre-defined in profile number 89).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgX3ModifCount 2.1.866.20.1.20.5.10.1.1.5
The value of this object indicates how many X3 parameters have not the value defined in the profile specified by fclAsynCfgX3ProfileId (i.e how many individual modifications).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fclAsynCfgConnectionProfileId 2.1.866.20.1.20.5.10.1.1.6
The value of this object is the profile number used to automatically valorize all the connection parameters in an entry of the three tables which composes the connection part of asynchronous configurations (see fclAsynCfgConfigId). The possible values are : 07 Terminal with automatic baud rate detect, 08 Direct connected terminal, 09 Terminal connection PSTN, 10 Terminal connected by dedicated line, 11 LSCP terminal - direct connection, 12 LSCP terminal - dedicated line connection, 13 LSCP-A terminal - direct connection, 14 LSCP-A terminal - dedicated line connection, 15 Minitel terminal - direct connection, 16 Minitel terminal - PSTN connection, 34 TTY terminal - PSTN connection (V.25 bis), 35 Minitel terminal - PSTN connection (V.25 bis), 36 Minitel terminal - PSTN connection (modem turnaround), 37 Multistandard videotex terminal, 38 Kiosk micro computer, If it is unused, the value of this parameter is '255'. The default value is '8' (meaning that default values of connection parameters are those pre-defined in profile number 08).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgConnModifCount 2.1.866.20.1.20.5.10.1.1.7
The value of this object indicates how many connection parameters have not the value defined in the profile specified by fclAsynCfgConnectionProfileId (i.e how many individual modifications).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fclAsynCfgX3Part1Table 2.1.866.20.1.20.5.10.11
This table contains the X3 parameters (part 1) of asynchronous configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynCfgX3Part1Entry

fclAsynCfgX3Part1Entry 2.1.866.20.1.20.5.10.11.1
An entry of fclAsynCfgX3Part1Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynCfgX3Part1Entry  

fclAsynCfgX3Part1ConfigId 2.1.866.20.1.20.5.10.11.1.1
The value of this object identifies one and only one asynchronous configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgX3Part1ProfileId 2.1.866.20.1.20.5.10.11.1.2
The value of this object is the X3 profile number used to create this configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgX3P01EscapeChar 2.1.866.20.1.20.5.10.11.1.11
The value of this object is the character to escape from the data transfer state and to recall the PAD. The authorized values are '0..126'. The value '0' indicates no escape. The value '1' is the DLE character. The values '2..126' are the ASCII code of the character. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..126  

fclAsynCfgX3P02Echo 2.1.866.20.1.20.5.10.11.1.12
The value of this object indicates whether the echo is local not. The authorized values are 'off' (echoing by the terminal), 'on' (echoing by the equipment). The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-off(1), val1-on(2)  

fclAsynCfgX3P03ForwardingChar 2.1.866.20.1.20.5.10.11.1.13
The value of this object is the data forwarding character(s). The authorized values are 'none' (no character), 'CR' (Carriage Return), 'CR ESC BEL ENQ ACK' (Carriage Return, Escape, Bell, Enquire, Acknowledge), 'CR EOT ETX' (Carriage Return, End Of Text, End Of Transmission), 'HT LF VT FF' (Horizontal Tabulation, Line Feed, Vertical Tabulation, Form Feed), 'all Ctrl Chars' (all control characters), 'all Chars' (all characters), 'all Ctrl Chars vdxFunctionKeys' (all control characters and videotext function keys), 'encapsCharacSLIP', 'encapsCharacPPP'. The default value is 'all Ctrl Chars'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val2-cr(3), val6-crEscBelEnqAck(7), val18-crEotEtx(19), val32-htLfVtFf(33), val126-allCtrlChars(127), val127-allChars(128), val128-allCtrlChars-vdxFunctionKeys(129), val253-encapsCharacSLIP(254), val254-encapsCharacPPP(255)  

fclAsynCfgX3P04IdleTimerDelay 2.1.866.20.1.20.5.10.11.1.14
The value of this object is the idle timer delay in twentieths of a second. The authorized values are '0..250'. The value '0' will indicate that no data forwarding on time-out is required. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynCfgX3P05OutputFlowCtrl 2.1.866.20.1.20.5.10.11.1.15
The value of this object indicates the flow control type from the equipment to the terminal. The authorized values are 'none' (no use of XON and XOFF), 'xonXoffInTransfer' (use of XON and XOFF in data transfer), 'xonXoff' (use of XON and XOFF in data transfer and command), 'rtsCtsInTransfer' (use of CTS and RTS signals in transfer). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-xonXoffInTransfer(2), val2-xonXoff(3), val8-rtsCtsInTransfer(9)  

fclAsynCfgX3P06ServiceSignals 2.1.866.20.1.20.5.10.11.1.16
The value of this object is the control of service signals and command signals sent by the equipment. The authorized values are 'none' (no service signals are transmitted to the start-stop mode DTE), 'servSignal-stdFormat' (service signals other than the prompt PAD service signal are transmitted in the standard format), 'servSignalAndPrompt-stdFormat' (service signals and the prompt service signal are transmitted in the standard format), 'servSignal-explicitFormat' (service signals other than the prompt service signal are transmitted in the explicit format), 'servSignalAndPrompt-explicitFormat' (service signals and the prompt service signal are transmitted in the explicit format). The default value is 'servSignalAndPrompt-explicitFormat'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-servSignal-stdFormat(2), val5-servSignalAndPrompt-stdFormat(6), val9-servSignal-explicitFormat(10), val13-servSignalAndPrompt-explicitFormat(14)  

fclAsynCfgX3P07BreakHandling 2.1.866.20.1.20.5.10.11.1.17
The value of this object is the selection of equipment operations on receipt of break signal from the start-stop mode DTE. The authorized values are 'forwardingChar' (no particular operation), 'interrupt' (send to packet mode DTE or other PAD an interrupt packet), 'reset' (reset), 'interrupt-breakIndication' (send to packet mode DTE or other PAD an interrupt packet and an indication of break PAD message), 'escapeFromTransfer' (escape from data transfer state), 'interrupt-breakIndication-discardOutput' (send to packet mode DTE or other PAD an interrupt packet and an indication of break PAD message, and discard output to start-stop mode DTE). The default value is 'reset'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-forwardingChar(1), val1-interrupt(2), val2-reset(3), val4-breakIndication(5), val5-interrupt-breakIndication(6), val8-escapeFromTransfer(9), val21-interrupt-breakIndication-discardOutput(22)  

fclAsynCfgX3P08OutputDiscard 2.1.866.20.1.20.5.10.11.1.18
The value of this object indicates whether data are sent to the terminal or not. The authorized values are 'off' (normal data delivery to the start-stop mode DTE), 'on' (discard output to start-stop mode DTE). The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-off(1), val1-on(2)  

fclAsynCfgX3P09CrPadding 2.1.866.20.1.20.5.10.11.1.19
The value of this object indicates the padding after carriage return. The authorized values are '0..250'. A value between '0' and '250' will indicate the number of padding characters to be generated by the equipment after a carriage return character is transmitted to the start-stop mode DTE. When the value of this parameter is '0', there will be no padding except that PAD service signals will contain a number of padding characters according to the data rate of the start-stop mode DTE. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynCfgX3P10LineFolding 2.1.866.20.1.20.5.10.11.1.20
The value of this object indicates the line folding. The authorized values are '0..250'. The value '0' indicates no line folding. A value between '1' and '250' will indicate the number of graphic characters per line that will be transmitted by the equipment without inserting appropriate format effectors. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynCfgX3P11BinarySpeed 2.1.866.20.1.20.5.10.11.1.21
The value of this object is the binary speed in bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-110(1), val1-134-5(2), val2-300(3), val3-1200(4), val4-600(5), val5-75(6), val6-150(7), val7-1800(8), val8-200(9), val9-100(10), val10-50(11), val11-in75Out1200(12), val12-2400(13), val13-4800(14), val14-9600(15), val15-19200(16), val23-28800(24), val17-57600(18), val20-38400(21), val21-out1200In75(22), val22-115200(23)  

fclAsynCfgX3Part2Table 2.1.866.20.1.20.5.10.12
This table contains the X3 parameters (part 2) of asynchronous configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynCfgX3Part2Entry

fclAsynCfgX3Part2Entry 2.1.866.20.1.20.5.10.12.1
An entry of fclAsynCfgX3Part2Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynCfgX3Part2Entry  

fclAsynCfgX3Part2ConfigId 2.1.866.20.1.20.5.10.12.1.1
The value of this object identifies one and only one asynchronous configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgX3Part2ProfileId 2.1.866.20.1.20.5.10.12.1.2
The value of this object is the X3 profile number used to create this configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgX3P12InputFlowCtrl 2.1.866.20.1.20.5.10.12.1.22
The value of this object indicates the flow control type from the start-stop mode DTE to the equipment. The authorized values are 'none' (no use of XON and XOFF for flow control), 'xonXoff' (use of XON and XOFF for flow control), 'rtsCts' (use of RTS and CTS for flow control). The default value is 'xonXoff'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-xonXoff(2), val8-rtsCts(9)  

fclAsynCfgX3P13LfInsertion 2.1.866.20.1.20.5.10.12.1.23
The value of this object indicates where there is the Line Feed insertion after Carriage Return. The authorized values are 'none' (no Line Feed insertion), 'outCr' (insert Line Feed after each Carriage Return in the data stream to the start-stop mode DTE), 'inCr' (insert Line Feed after each Carriage Return in the data stream from the start-stop mode DTE), 'outCr-inCr' (insert Line Feed after each Carriage Return in the data stream from and to the start-stop mode DTE), 'outCrEcho' (insert Line Feed after each Carriage Return in the echo stream to the start-stop mode DTE), 'outCr-outCrEcho' ('outCr' + 'outCrEcho'), 'inCr-outCrEcho' ('inCr' + 'outCrEcho'), 'outCr-inCr-outCrEcho' ('outCr-inCr' + 'outCrEcho'). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-outCr(2), val2-inCr(3), val3-outCr-inCr(4), val4-outCrEcho(5), val5-outCr-outCrEcho(6), val6-inCr-outCrEcho(7), val7-outCr-inCr-outCrEcho(8)  

fclAsynCfgX3P14LfPadding 2.1.866.20.1.20.5.10.12.1.24
The value of this object is the Line Feed padding. The authorized values are '0..250'. A value between '0' and '250' will indicate the number of padding characters to be generated by the equipement after a Line Feed character transmitted to the start-stop mode DTE during the data transfer state. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynCfgX3P15Editing 2.1.866.20.1.20.5.10.12.1.25
The value of this object indicates the editing mode. The authorized values are 'off', 'on'. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-off(1), val1-on(2)  

fclAsynCfgX3P16CharDelete 2.1.866.20.1.20.5.10.12.1.26
The value of this object is the 'character delete' character. The authorized values are '0..128'. The default value is '127'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

fclAsynCfgX3P17LineDelete 2.1.866.20.1.20.5.10.12.1.27
The value of this object is the 'line delete' character. The authorized values are '0..128'. The default value is '24'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

fclAsynCfgX3P18LineDisplay 2.1.866.20.1.20.5.10.12.1.28
The value of this object is the 'line display' character. The authorized values are '0..127'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fclAsynCfgX3P19EditingSignal 2.1.866.20.1.20.5.10.12.1.29
The value of this object defines the editing PAD service signals. The authorized values are 'none' (no editing PAD service signals), 'printingTerminal' (editing PAD service signals for printing terminals), 'displayTerminal' (editing PAD service signals for display terminals). The default value is 'displayTerminal'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-printingTerminal(2), val2-displayTerminal(3)  

fclAsynCfgX3P20EchoMask 2.1.866.20.1.20.5.10.12.1.30
The value of this object is the echo mask. The authorized values are '0..255'. The default value is '64'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fclAsynCfgX3P21Parity 2.1.866.20.1.20.5.10.12.1.31
The value of this object indicates the parity treatment. The authorized values are 'none' (no parity checking or generation), 'check' (parity checking), 'generate' (parity generation), 'check-generate' (parity checking and generation). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-check(2), val2-generate(3), val3-check-generate(4)  

fclAsynCfgX3P22PageWait 2.1.866.20.1.20.5.10.12.1.32
The value of this object defines the page wait. The authorized values are '0..127'. The value '0' indicates that the page wait is disabled. A value between '1' and '127' is the number of Line Feed characters sent by the equipment to the start-stop mode DTE. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fclAsynCfgX3UserProfilePart1 2.1.866.20.1.20.5.10.15
OBJECT IDENTIFIER    

fclAsynCfgX3UserProfileId 2.1.866.20.1.20.5.10.15.3
The value of this object is 80 the number of the user profile. This profile may be used, as any other X3 profile, to make a new asynchronous configuration in fclAsynCfgConfigTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgX3UserProfileDesc 2.1.866.20.1.20.5.10.15.4
The value of this object stores a text description of the user profile elaborated by the user. This description may contains from 0 to 32 characters. The default value is 'User profile'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

fclAsynCfgX3UserP01EscapeChar 2.1.866.20.1.20.5.10.15.11
The value of this object is the character to escape from the data transfer state and to recall the PAD. The authorized values are '0..126'. The value '0' indicates no escape. The value '1' is the DLE character. The values '2..126' are the ASCII code of the character. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..126  

fclAsynCfgX3UserP02Echo 2.1.866.20.1.20.5.10.15.12
The value of this object indicates whether the echo is local not. The authorized values are 'off' (echoing by the terminal), 'on' (echoing by the equipment). The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-off(1), val1-on(2)  

fclAsynCfgX3UserP03ForwardingChar 2.1.866.20.1.20.5.10.15.13
The value of this object is the data forwarding character(s). The authorized values are 'none' (no character), 'CR' (Carriage Return), 'CR ESC BEL ENQ ACK' (Carriage Return, Escape, Bell, Enquire, Acknowledge), 'CR EOT ETX' (Carriage Return, End Of Text, End Of Transmission), 'HT LF VT FF' (Horizontal Tabulation, Line Feed, Vertical Tabulation, Form Feed), 'all Ctrl Chars' (all control characters), 'all Chars' (all characters), 'all Ctrl Chars vdxFunctionKeys' (all control characters and videotext function keys) 'encapsCharacSLIP', 'encapsCharacPPP'. The default value is 'all Ctrl Chars'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val2-cr(3), val6-crEscBelEnqAck(7), val18-crEotEtx(19), val32-htLfVtFf(33), val126-allCtrlChars(127), val127-allChars(128), val128-allCtrlChars-vdxFunctionKeys(129), val253-encapsCharacSLIP(254), val254-encapsCharacPPP(255)  

fclAsynCfgX3UserP04IdleTimerDelay 2.1.866.20.1.20.5.10.15.14
The value of this object is the idle timer delay in twentieths of a second. The authorized values are '0..250'. The value '0' will indicate that no data forwarding on time-out is required. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynCfgX3UserP05OutputFlowCtrl 2.1.866.20.1.20.5.10.15.15
The value of this object indicates the flow control type from the equipment to the terminal. The authorized values are 'none' (no use of XON and XOFF), 'xonXoffInTransfer' (use of XON and XOFF in data transfer), 'xonXoff' (use of XON and XOFF in data transfer and command), 'rtsCtsInTransfer' (use of CTS and RTS signals in transfer). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-xonXoffInTransfer(2), val2-xonXoff(3), val8-rtsCtsInTransfer(9)  

fclAsynCfgX3UserP06ServiceSignals 2.1.866.20.1.20.5.10.15.16
The value of this object is the control of service signals and command signals sent by the equipment. The authorized values are 'none' (no service signals are transmitted to the start-stop mode DTE), 'servSignal-stdFormat' (service signals other than the prompt PAD service signal are transmitted in the standard format), 'servSignalAndPrompt-stdFormat' (service signals and the prompt service signal are transmitted in the standard format), 'servSignal-explicitFormat' (service signals other than the prompt service signal are transmitted in the explicit format), 'servSignalAndPrompt-explicitFormat' (service signals and the prompt service signal are transmitted in the explicit format). The default value is 'servSignalAndPrompt-explicitFormat'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-servSignal-stdFormat(2), val5-servSignalAndPrompt-stdFormat(6), val9-servSignal-explicitFormat(10), val13-servSignalAndPrompt-explicitFormat(14)  

fclAsynCfgX3UserP07BreakHandling 2.1.866.20.1.20.5.10.15.17
The value of this object is the selection of equipment operations on receipt of break signal from the start-stop mode DTE. The authorized values are 'forwardingChar' (no particular operation), 'interrupt' (send to packet mode DTE or other PAD an interrupt packet), 'reset' (reset), 'interrupt-breakIndication' (send to packet mode DTE or other PAD an interrupt packet and an indication of break PAD message), 'escapeFromTransfer' (escape from data transfer state), 'interrupt-breakIndication-discardOutput' (send to packet mode DTE or other PAD an interrupt packet and an indication of break PAD message, and discard output to start-stop mode DTE). The default value is 'reset'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-forwardingChar(1), val1-interrupt(2), val2-reset(3), val4-breakIndication(5), val5-interrupt-breakIndication(6), val8-escapeFromTransfer(9), val21-interrupt-breakIndication-discardOutput(22)  

fclAsynCfgX3UserP08OutputDiscard 2.1.866.20.1.20.5.10.15.18
The value of this object indicates whether data are sent to the terminal or not. The authorized values are 'off' (normal data delivery to the start-stop mode DTE), 'on' (discard output to start-stop mode DTE). The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-off(1), val1-on(2)  

fclAsynCfgX3UserP09CrPadding 2.1.866.20.1.20.5.10.15.19
The value of this object indicates the padding after carriage return. The authorized values are '0..250'. A value between '0' and '250' will indicate the number of padding characters to be generated by the equipment after a carriage return character is transmitted to the start-stop mode DTE. When the value of this parameter is '0', there will be no padding except that PAD service signals will contain a number of padding characters according to the data rate of the start-stop mode DTE. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynCfgX3UserP10LineFolding 2.1.866.20.1.20.5.10.15.20
The value of this object indicates the line folding. The authorized values are '0..250'. The value '0' indicates no line folding. A value between '1' and '250' will indicate the number of graphic characters per line that will be transmitted by the equipment without inserting appropriate format effectors. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynCfgX3UserP11BinarySpeed 2.1.866.20.1.20.5.10.15.21
The value of this object is the binary speed in bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-110(1), val1-134-5(2), val2-300(3), val3-1200(4), val4-600(5), val5-75(6), val6-150(7), val7-1800(8), val8-200(9), val9-100(10), val10-50(11), val11-75-1200(12), val12-2400(13), val13-4800(14), val14-9600(15), val15-19200(16), val23-28800(24), val17-57600(18), val20-38400(21), val21-1200-75(22), val22-115200(23)  

fclAsynCfgX3UserProfilePart2 2.1.866.20.1.20.5.10.16
OBJECT IDENTIFIER    

fclAsynCfgX3UserP12InputFlowCtrl 2.1.866.20.1.20.5.10.16.22
The value of this object indicates the flow control type from the start-stop mode DTE to the equipment. The authorized values are 'none' (no use of XON and XOFF for flow control), 'xonXoff' (use of XON and XOFF for flow control), 'rtsCts' (use of RTS and CTS for flow control). The default value is 'xonXoff'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-xonXoff(2), val8-rtsCts(9)  

fclAsynCfgX3UserP13LfInsertion 2.1.866.20.1.20.5.10.16.23
The value of this object indicates where there is the Line Feed insertion after Carriage Return. The authorized values are 'none' (no Line Feed insertion), 'outCr' (insert Line Feed after each Carriage Return in the data stream to the start-stop mode DTE), 'inCr' (insert Line Feed after each Carriage Return in the data stream from the start-stop mode DTE), 'outCr-inCr' (insert Line Feed after each Carriage Return in the data stream from and to the start-stop mode DTE), 'outCrEcho' (insert Line Feed after each Carriage Return in the echo stream to the start-stop mode DTE), 'outCr-outCrEcho' ('outCr' + 'outCrEcho'), 'inCr-outCrEcho' ('inCr' + 'outCrEcho'), 'outCr-inCr-outCrEcho' ('outCr-inCr' + 'outCrEcho'). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-outCr(2), val2-inCr(3), val3-outCr-inCr(4), val4-outCrEcho(5), val5-outCr-outCrEcho(6), val6-inCr-outCrEcho(7), val7-outCr-inCr-outCrEcho(8)  

fclAsynCfgX3UserP14LfPadding 2.1.866.20.1.20.5.10.16.24
The value of this object is the Line Feed padding. The authorized values are '0..250'. A value between '0' and '250' will indicate the number of padding characters to be generated by the equipement after a Line Feed character transmitted to the start-stop mode DTE during the data transfer state. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclAsynCfgX3UserP15Editing 2.1.866.20.1.20.5.10.16.25
The value of this object indicates the editing mode. The authorized values are 'off', 'on'. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-off(1), val1-on(2)  

fclAsynCfgX3UserP16CharDelete 2.1.866.20.1.20.5.10.16.26
The value of this object is the 'character delete' character. The authorized values are '0..128'. The default value is '127'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

fclAsynCfgX3UserP17LineDelete 2.1.866.20.1.20.5.10.16.27
The value of this object is the 'line delete' character. The authorized values are '0..128'. The default value is '24'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

fclAsynCfgX3UserP18LineDisplay 2.1.866.20.1.20.5.10.16.28
The value of this object is the 'line display' character. The authorized values are '0..127'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fclAsynCfgX3UserP19EditingSignal 2.1.866.20.1.20.5.10.16.29
The value of this object defines the editing PAD service signals. The authorized values are 'none' (no editing PAD service signals), 'printingTerminal' (editing PAD service signals for printing terminals), 'displayTerminal' (editing PAD service signals for display terminals). The default value is 'displayTerminal'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-printingTerminal(2), val2-displayTerminal(3)  

fclAsynCfgX3UserP20EchoMask 2.1.866.20.1.20.5.10.16.30
The value of this object is the echo mask. The authorized values are '0..255'. The default value is '64'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fclAsynCfgX3UserP21Parity 2.1.866.20.1.20.5.10.16.31
The value of this object indicates the parity treatment. The authorized values are 'none' (no parity checking or generation), 'check' (parity checking), 'generate' (parity generation), 'check-generate' (parity checking and generation). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0-none(1), val1-check(2), val2-generate(3), val3-check-generate(4)  

fclAsynCfgX3UserP22PageWait 2.1.866.20.1.20.5.10.16.32
The value of this object defines the page wait. The authorized values are '0..127'. The value '0' indicates that the page wait is disabled. A value between '1' and '127' is the number of Line Feed characters sent by the equipment to the start-stop mode DTE. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fclAsynCfgConnLinkTable 2.1.866.20.1.20.5.10.21
This table contains the connection parameters (link part) of asynchronous configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynCfgConnLinkEntry

fclAsynCfgConnLinkEntry 2.1.866.20.1.20.5.10.21.1
An entry of fclAsynCfgConnLinkTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynCfgConnLinkEntry  

fclAsynCfgLinkConfigId 2.1.866.20.1.20.5.10.21.1.1
The value of this object identifies one and only one asynchronous configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgLinkXonXoffParity 2.1.866.20.1.20.5.10.21.1.2
The value of this object indicates the XON/XOFF parity. The default value is 'even'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(3), even(1), odd(2)  

fclAsynCfgLinkServSignalParity 2.1.866.20.1.20.5.10.21.1.3
The value of this object indicates the signals parity. The default value is 'even'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(3), even(1), odd(2)  

fclAsynCfgLinkDataParity 2.1.866.20.1.20.5.10.21.1.4
The value of this object indicates the data parity. The default value is 'even'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), even(4), odd(2)  

fclAsynCfgLinkBitCount 2.1.866.20.1.20.5.10.21.1.5
The value of this object indicates the number of bits by characters. The authorized values are '7' or '8'. The default value is '7'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 7..8  

fclAsynCfgLinkStopBitCount 2.1.866.20.1.20.5.10.21.1.6
The value of this object defines the number of stop bits. The default value is 'one'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(4), oneAndAHalf(8), two(12)  

fclAsynCfgLinkXonXoffSignal 2.1.866.20.1.20.5.10.21.1.7
The value of this object indicates if there are a transmission of XOFF when moving to the command mode and a transmission of XON when moving to the data transmission mode. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynCfgLinkInactivityTimer 2.1.866.20.1.20.5.10.21.1.8
The value of this object defines the line inactivity time-out in transfer state. When the time-out expires, the call is cleared. For a Minitel using a PSTN profile, the telephone communication is cut when the VC is cleared (This after T/2 seconds). The authorized values are '0..2500'. The value '0' indicates no time-out. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2500  

fclAsynCfgLinkBlockSize 2.1.866.20.1.20.5.10.21.1.9
The value of this object indicates the number of bytes received by the equipment in the receive buffers. The authorized values are '1..128'. The default value is '128'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..128  

fclAsynCfgLinkCallResponseTimer 2.1.866.20.1.20.5.10.21.1.10
The value of this object is the supervision time-out for response to a call request packet sent on the link. A clear packet is sent if there is no response after this period. The authorized values are '10..2500'. The default value is '20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fclAsynCfgConnFacilityTable 2.1.866.20.1.20.5.10.25
This table contains the connection parameters (facility part) of asynchronous configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynCfgConnFacilityEntry

fclAsynCfgConnFacilityEntry 2.1.866.20.1.20.5.10.25.1
An entry of fclAsynCfgConnFacilityTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynCfgConnFacilityEntry  

fclAsynCfgFacConfigId 2.1.866.20.1.20.5.10.25.1.1
The value of this object identifies one and only one asynchronous configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgFacClosedUserGroup 2.1.866.20.1.20.5.10.25.1.2
The value of this object specifies the behaviour of the equipment with respect to the Closed User Group (CUG) facility. There are 3 possible values : noCheck : the CUG is not checked, clear : clearing if the CUG is present in the call packet, subscribe : clearing if the CUG is not present in the call packet. The default value is 'noCheck'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(2), clear(1), subscribe(3)  

fclAsynCfgFacReverseCharging 2.1.866.20.1.20.5.10.25.1.3
The value of this object specifies the behaviour of the equipment with respect to the reverse charging facility. If the called subscriber doesn't accept the reverse charging, the call is not transmitted and a clear is sent. The default value is 'refuse'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER refuse(1), accept(2)  

fclAsynCfgFacThroughputClass 2.1.866.20.1.20.5.10.25.1.10
The value of this object indicates if the subscriber connected to the link has subscribed to throughput class negociation facility. The authorized values are 'clear' (not subscriber) or 'subscribe'. The default value is 'clear'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), subscribe(2)  

fclAsynCfgFacDefOutThroughputClass 2.1.866.20.1.20.5.10.25.1.11
The value of this object indicates the default throughput class in transmit direction (equipment to remote peer). The default value is 9600 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclAsynCfgFacDefInThroughputClass 2.1.866.20.1.20.5.10.25.1.12
The value of this object indicates the default throughput class in receive direction (remote peer to equipment). The default value is 9600 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclAsynCfgFacMaxOutThroughputClass 2.1.866.20.1.20.5.10.25.1.13
The value of this object indicates the maximum throughput class in transmit direction (equipment to remote peer). The default value is 9600 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclAsynCfgFacMaxInThroughputClass 2.1.866.20.1.20.5.10.25.1.14
The value of this object indicates the maximum throughput class in receive direction (remote peer to equipment). The default value is 9600 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclAsynCfgFacPacketSize 2.1.866.20.1.20.5.10.25.1.20
The value of this object indicates if the subscriber connected to the link has subscribed to packet size negociation facility. The authorized values are 'clear' (not subscriber) or 'subscribe'. The default value is 'clear'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), subscribe(2)  

fclAsynCfgFacDefOutPacketSize 2.1.866.20.1.20.5.10.25.1.21
The value of this object indicates the default packet size in transmit direction (equipment to remote peer). The default value is 128 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclAsynCfgFacDefInPacketSize 2.1.866.20.1.20.5.10.25.1.22
The value of this object indicates the default packet size in receive direction (remote peer to equipment). The default value is 128 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclAsynCfgFacMaxOutPacketSize 2.1.866.20.1.20.5.10.25.1.23
The value of this object indicates the maximum packet size in transmit direction (equipment to remote peer). The default value is 128 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclAsynCfgFacMaxInPacketSize 2.1.866.20.1.20.5.10.25.1.24
The value of this object indicates the maximum packet size in receive direction (remote peer to equipment). The default value is 128 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclAsynCfgFacMinOutPacketSize 2.1.866.20.1.20.5.10.25.1.25
The value of this object indicates the minimum packet size in transmit direction (equipment to remote peer). The default value is 16 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclAsynCfgFacMinInPacketSize 2.1.866.20.1.20.5.10.25.1.26
The value of this object indicates the minimum packet size in receive direction (remote peer to equipment). The default value is 16 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclAsynCfgFacWindowSize 2.1.866.20.1.20.5.10.25.1.30
The value of this object indicates if the subscriber connected to the link has subscribed to the negociation of the transmit window size facility. The authorized values are 'clear' (not subscriber) or 'subscribe'. The default value is 'clear'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), subscribe(2)  

fclAsynCfgFacDefOutWindowSize 2.1.866.20.1.20.5.10.25.1.31
The value of this object indicates the default window size in transmit direction (equipment to remote peer). The authorized values are '1..7'. The default value is '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclAsynCfgFacDefInWindowSize 2.1.866.20.1.20.5.10.25.1.32
The value of this object indicates the default window size in receive direction (remote peer to equipment). The authorized values are '1..7'. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclAsynCfgFacMaxOutWindowSize 2.1.866.20.1.20.5.10.25.1.33
The value of this object indicates the maximum window size in transmit direction (equipment to remote peer). The authorized values are '1..7'. The default value is '3'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclAsynCfgFacMaxInWindowSize 2.1.866.20.1.20.5.10.25.1.34
The value of this object indicates the maximum window size in receive direction (remote peer to equipment). The authorized values are '1..7'. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclAsynCfgConnServiceTable 2.1.866.20.1.20.5.10.30
This table contains the connection parameters (service part) of asynchronous configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynCfgConnServiceEntry

fclAsynCfgConnServiceEntry 2.1.866.20.1.20.5.10.30.1
An entry of fclAsynCfgConnServiceTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynCfgConnServiceEntry  

fclAsynCfgSerConfigId 2.1.866.20.1.20.5.10.30.1.1
The value of this object identifies one and only one asynchronous configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclAsynCfgSerCompression 2.1.866.20.1.20.5.10.30.1.2
The value of this object indicates the compression enabling for each direction. The authorized values are : off : no compression, networkToSubscriber : compression of the flow from the remote peer to the equipment, subscriberToNetwork : compression of the flow from the equipment to the remote peer, bothway : compression of the two flows from and to the equipment. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), networkToSubscriber(2), subscriberToNetwork(3), bothway(4)  

fclAsynCfgSerCompressNegociation 2.1.866.20.1.20.5.10.30.1.3
The value of this object indicates whether the compression facility is negociated or not and, if negociated, the optional/obligatory status. The authorized values are : off' :no negociation, onOptionalCompression : negociation but compression is optional, onMandatoryCompression : negociation and compression is mandatory. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onOptionalCompression(2), onMandatoryCompression(3)  

fclAsynCfgSerCompressScrambling 2.1.866.20.1.20.5.10.30.1.4
The value of this object indicates, when the compression is active, whether the scrambling is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynCfgSerCompressMultiPacketsTimer 2.1.866.20.1.20.5.10.30.1.5
The value of this object defines the maximum waiting time, in milliseconds by steps of 100 milliseconds , which, if there is not another packet to compress, the packet of compressed packets is sent beyond (this permits to reduce the number of packets transmitted to the remote peer). The authorized values are '0..1500'. '0' means no packets grouping (i. e. : each packet is individually compressed and sent). The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

fclAsynCfgSerX29Reselection 2.1.866.20.1.20.5.10.30.1.6
The value of this object indicates whether the subscriber connected to the link has subscribed to X29 reselection or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynCfgSerCallReturnTransmission 2.1.866.20.1.20.5.10.30.1.7
The value of this object indicates whether the 'call return' packet may be sent on this link or not. The 'call return' packet, sent to the previous equipment, makes this equipments search for another route to join the called DTE. The defaut value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(3)  

fclAsynCfgSerDBitModification 2.1.866.20.1.20.5.10.30.1.8
The value of this object specifies the management of the D bit. The authorized values are 'off' or 'clear' (in this case, there is clearing ....) or 'on'. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(2), on(3)  

fclAsynCfgSerReliableVc 2.1.866.20.1.20.5.10.30.1.9
The value of this object is used to enable the Reliable Virtual Circuit service. The authorized values are : off : no RVC, the VCs are considered as normal VCs, no particular processing, clear : RVCs are not allowed for the subscriber, each attempt to establish a RVC provokes a clear of the connection, subscribe : all calls transmitted by the subscriber establish RVCs, it is also possible to receive calls with RVC option, check : for a link to a subscriber : when a call with RVC option is received, a RVC is established for a link to a network : the RVC option is ignored when it is present in a call sent by a local subscriber, the connection is cleared when the RVC option is present in a call sent by the network. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(3), subscribe(2), check(4)  

fclAsynCfgSerCos 2.1.866.20.1.20.5.10.30.1.20
COS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1)  

fclAsynCfgSerCir 2.1.866.20.1.20.5.10.30.1.21
Entrant CIR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 600..2048000  

fclAsynCfgSerMinCir 2.1.866.20.1.20.5.10.30.1.22
Entrant CIR mini
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclAsynCfgSerConversionAimedPoint 2.1.866.20.1.20.5.10.30.1.30
Conversion adresse : point vise
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynCfgSerConversionIncomingCall 2.1.866.20.1.20.5.10.30.1.31
Conversion d'adresse sur appel entrant
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fclAsynCfgSerConversionOutgoingCall 2.1.866.20.1.20.5.10.30.1.32
Conversion adresse sur appel sortant
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fclAsynCfgSerConversionAddressCheck 2.1.866.20.1.20.5.10.30.1.33
Conversion adresse : controle de la presence dans les tables de conversion
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(4)  

fclAsynAutoCalls 2.1.866.20.1.20.5.20
OBJECT IDENTIFIER    

fclAsynAutoCallTable 2.1.866.20.1.20.5.20.1
This table contains the asynchronous logical ports for which a call is automatically sent when the operational state of this LP becomes 'up'. For each LP this table defines the addres of the called remote peer and the different parameters of the call processing.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynAutoCallEntry

fclAsynAutoCallEntry 2.1.866.20.1.20.5.20.1.1
An entry of fclAsynAutoCallTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynAutoCallEntry  

fclAsynAutoLogPortId 2.1.866.20.1.20.5.20.1.1.1
The value of this object identifies one and only one asynchronous logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclAsynAutoStatus 2.1.866.20.1.20.5.20.1.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclAsynAutoCalledAddr 2.1.866.20.1.20.5.20.1.1.5
The value of this object is the X121 address of the called remote peer. This value is the called address specified in the call packet sent from this logical port. The value may contain up to 15 digits (digits 0..9). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclAsynAutoFacility 2.1.866.20.1.20.5.20.1.1.6
The value of this object indicates the facilities set in the call packet. The authorized values are 'none' (no facility), 'reverseCharging' (code '0101'), 'cug' (code '0300'), 'reverseCharging-cug' (code '01010300'), 'throughputClass' (code '02xx' where 'x' is the throughput class code defined by fclAsynAutoFacThroughputClass). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), reverseCharging(2), cug(3), reverseCharging-cug(4), throughputClass(5)  

fclAsynAutoFacThroughputClass 2.1.866.20.1.20.5.20.1.1.7
The value of this object indicates the throughput class facility set in the call packet when the object fclAsynAutoFacility is set to 'throughputClass'. The authorized values, in bits per second, are 75 (code '3'), 150 (code '4'), 300 (code '5'), 600 (code '6'), 1200 (code '7'), 2400 (code '8'), 4800 (code '9'), 9600 (code 'A'), 19200 (code 'B'), 48000 (code 'C'), 64000 (code 'D'), 128000 (code 'E'), 192000 (code 'F'). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclAsynAutoCallUserDataAscii 2.1.866.20.1.20.5.20.1.1.10
The value of this object is the call user data specified in DisplayString format. When both objects fclAsynAutoCallUserDataAscii and fclAsynAutoCallUserDataAscii are not empty the first one is ignored. The value may contain up to 12 characters. The default value is an empty string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..12)  

fclAsynAutoCallUserDataHexa 2.1.866.20.1.20.5.20.1.1.11
The value of this object is the call user data specified in OCTET STRING format. When both objects fclAsynAutoCallUserDataAscii and fclAsynAutoCallUserDataAscii are not empty the first one is ignored. 13 bytes from 00 to FF must be specified. The first byte contains the number of following useful bytes. The trailing bytes must be set to 'FF'. The equipment configurator does not need this final completion. The default value is 'empty' (first byte set to '00').
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(13)  

fclAsynAutoMinimumRecallTimer 2.1.866.20.1.20.5.20.1.1.15
The value of this object specifies the minimum recall time (in seconds) between two successive calls. The authorized values are '0..990' by step of 10. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclAsynAutoDiscardCharDuringTimer 2.1.866.20.1.20.5.20.1.1.16
The value of this object specifies the reaction of the equipment receiving a character from the asynchronous device during the recall time : either stops the timer and lets the operator with his asynchronous device to type any X28 command ('No' value), or discards the character and lets go on the recall timer('Yes' value). The authorized values are 'Yes' or 'No'. The default value is 'No'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynAutoVdxKeyTranslationTable 2.1.866.20.1.20.5.20.2
This table contains the logical ports for which a call is automatically sent when the operational state of this LP becomes 'up'. This table describes how the videotext keyboard function keys are translated.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynAutoVdxKeyTranslationEntry

fclAsynAutoVdxKeyTranslationEntry 2.1.866.20.1.20.5.20.2.1
An entry of fclAsynAutoVdxKeyTranslationTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynAutoVdxKeyTranslationEntry  

fclAsynAutoTransLpId 2.1.866.20.1.20.5.20.2.1.1
The value of this object identifies one and only one asynchronous logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclAsynAutoTransTranscoding 2.1.866.20.1.20.5.20.2.1.2
The value of this object indicates whether the videotext keyboard function keys are transcoded or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynAutoTransProfile 2.1.866.20.1.20.5.20.2.1.3
The value of this object is the X3 profile number used during the transfert. The authorized values are 'p1' (profile number 1), 'p2' (profile number 2). The default value is 'p1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER p1(1), p2(2)  

fclAsynAutoTransAutoTermMode 2.1.866.20.1.20.5.20.2.1.4
The value of this object indicates whether the automatic changeover to data communication standard during data transfert is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynAutoTransCFKeyHandling 2.1.866.20.1.20.5.20.2.1.5
The value of this object indicates the handling of the videotext keyboard 'connexion/fin' key. The authorized values are 'local' (.....), 'remote' (....). The default value is 'local'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER local(1), remote(2)  

fclAsynAutoTransClearHangUp 2.1.866.20.1.20.5.20.2.1.6
The value of this object indicates whether the local communication is hang up (case PSTN link) when a clear packet is received or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynMnemonic 2.1.866.20.1.20.5.21
OBJECT IDENTIFIER    

fclAsynMnemonicTable 2.1.866.20.1.20.5.21.1
This table contains mnemonics that permit to associate names to remote peer. For each name this table defines the addres of the called remote peer and the different parameters of the call processing.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynMnemonicEntry

fclAsynMnemonicEntry 2.1.866.20.1.20.5.21.1.1
An entry of fclAsynMnemonicTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynMnemonicEntry  

fclAsynMneMnemonicId 2.1.866.20.1.20.5.21.1.1.1
The value of this object identifies one and only one mnemonic (this value is used as index of this table instead of the mnemonic name to make the SNMP managers handle correctly this table). The possible values are : '0..99'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

fclAsynMneStatus 2.1.866.20.1.20.5.21.1.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclAsynMneName 2.1.866.20.1.20.5.21.1.1.3
The value of this object is the mnemonic name. The value may contain up to 6 characters. The default value is an empty string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..6)  

fclAsynMneCalledAddr 2.1.866.20.1.20.5.21.1.1.5
The value of this object is the X121 address of the called remote peer. This value is the called address specified in the call packet sent from this logical port. The value may contain up to 15 digits (digits 0..9). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclAsynMneFacility 2.1.866.20.1.20.5.21.1.1.6
The value of this object indicates the facilities set in the call packet. The authorized values are 'none' (no facility), 'reverseCharging' (code '0101'), 'cug' (code '0300'), 'reverseCharging-cug' (code '01010300'), 'throughputClass' (code '02xx' where 'x' is the throughput class code defined by fclAsynMneFacThroughputClass). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), reverseCharging(2), cug(3), reverseCharging-cug(4), throughputClass(5)  

fclAsynMneFacThroughputClass 2.1.866.20.1.20.5.21.1.1.7
The value of this object indicates the throughput class facility set in the call packet when the object fclAsynMneFacility is set to 'throughputClass'. The authorized values, in bits per second, are 75 (code '3'), 150 (code '4'), 300 (code '5'), 600 (code '6'), 1200 (code '7'), 2400 (code '8'), 4800 (code '9'), 9600 (code 'A'), 19200 (code 'B'), 48000 (code 'C'), 64000 (code 'D'), 128000 (code 'E'), 192000 (code 'F'). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclAsynMneCallUserDataAscii 2.1.866.20.1.20.5.21.1.1.10
The value of this object is the call user data specified in DisplayString format. When both objects fclAsynMneCallUserDataAscii and fclAsynMneCallUserDataAscii are not empty the first one is ignored. The value may contain up to 12 characters. The default value is an empty string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..12)  

fclAsynMneCallUserDataHexa 2.1.866.20.1.20.5.21.1.1.11
The value of this object is the call user data specified in OCTET STRING format. When both objects fclAsynMneCallUserDataAscii and fclAsynMneCallUserDataAscii are not empty the first one is ignored. 13 bytes from 00 to FF must be specified. The first byte contains the number of following useful bytes. The trailing bytes must be set to 'FF'. The equipment configurator does not need this final completion. The default value is 'empty' (first byte set to '00').
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(13)  

fclAsynMneVdxKeyTranslationTable 2.1.866.20.1.20.5.21.2
This table contains mnemonics that permit to associate names to remote peer. This table describes how the videotext keyboard function keys are translated.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynMneVdxKeyTranslationEntry

fclAsynMneVdxKeyTranslationEntry 2.1.866.20.1.20.5.21.2.1
An entry of fclAsynMneVdxKeyTranslationTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynMneVdxKeyTranslationEntry  

fclAsynMneTransMnemonicId 2.1.866.20.1.20.5.21.2.1.1
The value of this object identifies one and only one mnemonic (this value is used as index of this table instead of the mnemonic name to make the SNMP managers handle correctly this table). The possible values are : '0..99. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

fclAsynMneTransName 2.1.866.20.1.20.5.21.2.1.2
The value of this object is the mnemonic name.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..6)  

fclAsynMneTransTranscoding 2.1.866.20.1.20.5.21.2.1.3
The value of this object indicates whether the videotext keyboard function keys are transcoded or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclAsynMneTransProfile 2.1.866.20.1.20.5.21.2.1.4
The value of this object is the X3 profile number used during the transfert. The authorized values are 'p1' (profile number 1), 'p2' (profile number 2). The default value is 'p1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER p1(1), p2(2)  

fclAsynMneTransAutoTermMode 2.1.866.20.1.20.5.21.2.1.5
The value of this object indicates whether the automatic changeover to data communication standard during data transfert is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynMneTransCFKeyHandling 2.1.866.20.1.20.5.21.2.1.6
The value of this object indicates the handling of the videotext keyboard 'connexion/fin' key. The authorized values are 'local' (.....), 'remote' (....). The default value is 'local'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER local(1), remote(2)  

fclAsynMneTransClearHangUp 2.1.866.20.1.20.5.21.2.1.7
The value of this object indicates whether the local communication is hang up (case PSTN link) when a clear packet is received or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclAsynPstnRemotePeerTable 2.1.866.20.1.20.5.25
This table contains the remote peers to call by Public Switched Telephone Network way.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynPstnRemotePeerEntry

fclAsynPstnRemotePeerEntry 2.1.866.20.1.20.5.25.1
An entry of fclAsynPstnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynPstnRemotePeerEntry  

fclAsynPstnRemX121Addr 2.1.866.20.1.20.5.25.1.1
The value of this object is the X121 address of the called remote peer. The value may contain up to 15 digits (digits 0..9, B, D). The digits 'B', 'D' (respectively characters '*', '?' on the equipment configurator) have special meanings : 'B' matches any address. When used it must be the only digit specified (with final completion as explained below). 'D' matches any single digit. The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclAsynPstnRemStatus 2.1.866.20.1.20.5.25.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclAsynPstnRemPstnNumber 2.1.866.20.1.20.5.25.1.3
The value of this object is the PSTN address of the called remote peer. The value may contain up to 28 digits (digits 0..E). The digits 'A', 'B', 'C', 'D', 'E' (respectively characters 'W', ',', 'P', 'T', '!' on the equipment configurator) have special meanings : 'A' means 'attente de tonalite', 'B' means 'pause of 2 seconds', 'C' means 'numerotation decimale', 'D' means 'numerotation multifrequence', 'E' means 'raccrocher 0.5 second'. The value must be completed with 'F' digits for a total of 28 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(14)  

fclAsynNetUserTable 2.1.866.20.1.20.5.26
This table contains user identifications.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclAsynNetUserEntry

fclAsynNetUserEntry 2.1.866.20.1.20.5.26.1
An entry of fclAsynNetUserTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclAsynNetUserEntry  

fclAsynNetUserId 2.1.866.20.1.20.5.26.1.1
The value of this object identifies one and only one user (this value is used as index of this table instead of the NUI to make the SNMP managers handle correctly this table). The possible values are : '0..254'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..254  

fclAsynNetStatus 2.1.866.20.1.20.5.26.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclAsynNetNui 2.1.866.20.1.20.5.26.1.3
The value of this object is the NUI (Network User Identifier). The authorized values are all the alphabetical characters strings on 6 characters. The default value is the empty string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..6)  

fclAsynNetNua 2.1.866.20.1.20.5.26.1.4
The value of this object is the NUA (Network User Access). The authorized values are '0..9999'. If it is unused, the value is '65535'. The default value is '65535'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9999  

fclFrameRelayAccessLogPort 2.1.866.20.1.20.13
OBJECT IDENTIFIER    

fclFraLogPortTable 2.1.866.20.1.20.13.1
This table defines the general parameters of Frame Relay Access logical ports. These FRA logical ports are used when X25 Virtual Channel must be established between local FR PVC (Frame Relay Permanent Virtual Circuit) end points and remote FR PVC end points through a X25 network. They are not adapted to cross a Frame Relay network (see FR CE logical ports in this case).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFraLogPortEntry

fclFraLogPortEntry 2.1.866.20.1.20.13.1.1
An entry of fclFraLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFraLogPortEntry  

fclFraLpLogPortId 2.1.866.20.1.20.13.1.1.1
The value of this object identifies one and only one Frame Relay Access logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFraLpInterfaceId 2.1.866.20.1.20.13.1.1.2
The value of this object identifies the line interface used by this FRA logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclFraLpLmi 2.1.866.20.1.20.13.1.1.3
The value of this object defines which kind of signalling is used on this FRA logical port. The possible values are 'off' (no signalling), lmiUni (Link Management Interface - User to Network Interface : the equipment performs user-side procedures), lmiNui (Link Management Interface - Network to User Interface : the equipment performs network-side procedures). The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), lmiUni(2), lmiNui(3)  

fclFraLpGroupingThreshold 2.1.866.20.1.20.13.1.1.5
The value of this object is the input resource threshold over which several input frames coming from a FR PVC end point are grouped in a single X25 packet to cross the X25 network. The enabling of this grouping is PVC end point specific (see fclFraPvcEncapsulation). The possible values are : '1..97'. The thresholds must be set as following : fclFraLpGroupingThreshold < fclFraLpFecnBecnThreshold < fclFraLpDeDiscardThreshold < fclFraLpAllDiscardThreshold. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..97  

fclFraLpFecnBecnThreshold 2.1.866.20.1.20.13.1.1.6
The value of this object is the input resource threshold over which bits FECN (Forward Explicit Congestion Notification) of input frames and BECN (Backward Explicit Congestion Notification) of output frames are set to 1. The possible values are : '2..98'. The thresholds must be set as following : fclFraLpGroupingThreshold < fclFraLpFecnBecnThreshold < fclFraLpDeDiscardThreshold < fclFraLpAllDiscardThreshold. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..98  

fclFraLpDeDiscardThreshold 2.1.866.20.1.20.13.1.1.7
The value of this object is the input resource threshold over which input frames with bit DE (Discard Eligible) set to 1 are discarded (i.e. : not sent accross the X25 network). The possible values are : '3..99'. The thresholds must be set as following : fclFraLpGroupingThreshold < fclFraLpFecnBecnThreshold < fclFraLpDeDiscardThreshold < fclFraLpAllDiscardThreshold. The default value is '15'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 3..99  

fclFraLpAllDiscardThreshold 2.1.866.20.1.20.13.1.1.8
The value of this object is the input resource threshold over which all input frames are discarded (i.e. : not sent accross the X25 network). The possible values are : '4..100'. The thresholds must be set as following : fclFraLpGroupingThreshold < fclFraLpFecnBecnThreshold < fclFraLpDeDiscardThreshold < fclFraLpAllDiscardThreshold. The default value is '20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..100  

fclFraLpX25InterframeFlagCount 2.1.866.20.1.20.13.1.1.9
The value of this object is the number of interframe flags (it concerns the framing aspects of link access procedures of X25 and not the fact to put several frames coming from a FR PVC end point in a single X25 packet). The possible values are : '1..15'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclFraLpInactivityCheckDelay 2.1.866.20.1.20.13.1.1.10
The value of this object is the inactivity check delay in minutes.............. The possible values are : '0..254'. The value '0' disables this clearing mechanism. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..254  

fclFraLpCompression 2.1.866.20.1.20.13.1.1.20
The value of this object indicates the compression enabling for each direction. The authorized values are : off : no compression, networkToSubscriber : compression of the flow from the remote peer to the equipment, subscriberToNetwork : compression of the flow from the equipment to the remote peer, bothway : compression of the two flows from and to the equipment. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), networkToSubscriber(2), subscriberToNetwork(3), bothway(4)  

fclFraLpCompressNegotiation 2.1.866.20.1.20.13.1.1.21
The value of this object indicates whether the compression facility is negociated or not and, if negociated, the optional/obligatory status. The authorized values are : off' :no negociation, onOptionalCompression : negociation but compression is optional, onMandatoryCompression : negociation and compression is mandatory. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onOptionalCompression(2), onMandatoryCompression(3)  

fclFraLpCompressScrambling 2.1.866.20.1.20.13.1.1.22
The value of this object indicates, when the compression is active, whether the scrambling is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclFraLpCompressMultiPacketsTimer 2.1.866.20.1.20.13.1.1.23
The value of this object defines the maximum waiting time, in milliseconds by steps of 100 milliseconds , which, if there is not another packet to compress, the packet of compressed packets is sent beyond (this permits to reduce the number of packets transmitted to the remote peer). The authorized values are '0..1500'. '0' means no packets grouping (i. e. : each packet is individually compressed and sent). The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

fclFraLpReliableVc 2.1.866.20.1.20.13.1.1.24
The value of this object is used to enable the Reliable Virtual Circuit service. The authorized values are : off : no RVC, the VCs are considered as normal VCs, no particular processing, clear : RVCs are not allowed for the subscriber, each attempt to establish a RVC provokes a clear of the connection, subscribe : all calls transmitted by the subscriber establish RVCs, it is also possible to receive calls with RVC option, check : for a link to a subscriber : when a call with RVC option is received, a RVC is established for a link to a network : the RVC option is ignored when it is present in a call sent by a local subscriber, the connection is cleared when the RVC option is present in a call sent by the network. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(3), subscribe(2), check(4)  

fclFraLmiTable 2.1.866.20.1.20.13.2
This table defines the LMI (Link Management Interface) parameters of Frame Relay Access logical ports with LMI signalling.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFraLmiEntry

fclFraLmiEntry 2.1.866.20.1.20.13.2.1
An entry of fclFraLmiTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFraLmiEntry  

fclFraLmiLogPortId 2.1.866.20.1.20.13.2.1.1
The value of this object identifies one and only one Frame Relay Access logical port with LMI (Link Management Interface) signalling. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFraLmiDlci 2.1.866.20.1.20.13.2.1.2
The value of this object is the DLCI Data Link Connection Identifier of the Frame Relay PVC (Permanent Virtual Circuit) used by LMI to exchange management datas with the facing peer. The possible values are '0' or '1023'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dlci0(1), dlci1023(2)  

fclFraLmiLmiStandard 2.1.866.20.1.20.13.2.1.3
The value of this object defines which standard is used. The possible values are 'ansiT1-617d' (ANSI T1.617 Annex D) or 'itutQ933a' (ITU-T Q.933 Annex A). The default value is 'ansiT1-617d'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ansiT1-617d(1), itutQ933a(2)  

fclFraLmiAccessibilityCondition 2.1.866.20.1.20.13.2.1.4
The value of this object defines calculation mode of the 'up' operational status of the logical port. The operational state may be deducted using the N393 mechanism (value 'n393') or, more rapidly, withoutis using this mechanism (value 'fast'). The default value is 'fast'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fast(1), n393(2)  

fclFraLmiN391FullStatusPollCount 2.1.866.20.1.20.13.2.1.5
The value of this object identifies the user-side N391 full status polling cycle value for this logical port. This the number of status enquiry intervals that pass before issuance of full status enquiry message. If the logical port is not performing user-side procedures, then this value is meaningless. The authorized values are '1..254'. The default value is '6'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fclFraLmiN392ErrorThreshold 2.1.866.20.1.20.13.2.1.6
The value of this object identifies the user-side or network-side N392 error threshold value for this logical port. This is the maximum number of unanswered Status Enquiries the equipment shall accept before declaring the logical port down. The authorized values are '1..10. The default value is '3'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

fclFraLmiN393MonitoredEventCount 2.1.866.20.1.20.13.2.1.7
The value of this object identifies the user-side or network-side N393 monitored events count value for this logical port. This is the number of status polling intervals over which the error threshold is counted. For example if within 'MonitoredEvents' number of events the equipment receives 'ErrorThreshold' number of errors, the logical port is marked as down. The authorized values are '1..10. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

fclFraLmiT391LinkIntegPollTimer 2.1.866.20.1.20.13.2.1.8
The value of this object identifies the user-side T391 link integrity verification polling timer value for this logical port. This is the number of seconds between successive status enquiry messages. If the logical port is not performing user-side procedures, then this value is meaningless. The authorized values are '5..30'. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

fclFraLmiT392PollingVerifTimer 2.1.866.20.1.20.13.2.1.9
The value of this object identifies the network-side T392 polling verification timer value (nT2 for LMI) for this logical port. This value is expressed in seconds. If the logical port is not performing network-side procedures, then this value is meaningless. The authorized values are '5..30'. The default value is '15'
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

fclFraPvcEndPointTable 2.1.866.20.1.20.13.3
This table defines the Frame Relay PVC (Permananent Virtual Circuit) end points on Frame Relay Access logical ports. For each PVC end point this table defines the addres of the called remote peer and the different parameters of the call processing.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFraPvcEndPointEntry

fclFraPvcEndPointEntry 2.1.866.20.1.20.13.3.1
An entry of fclFraPvcEndPointTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFraPvcEndPointEntry  

fclFraPvcLogPortId 2.1.866.20.1.20.13.3.1.1
The value of this object identifies one and only one Frame Relay Access logical port. This is the logical port this PVC (Permanent Virtual Circuit) end point is layered onto. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFraPvcDlci 2.1.866.20.1.20.13.3.1.2
The value of this object is equal to the DLCI (Data Link Connection Identifier) value for this PVC (Permanent Virtual Circuit) end point. The possible values are : '0..1023. If it is unused, the value of this parameter is '65535'. The default value is '65535'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..991  

fclFraPvcStatus 2.1.866.20.1.20.13.3.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFraPvcCalledAddr 2.1.866.20.1.20.13.3.1.5
The value of this object is the X121 address of the called remote peer PVC end point. This value is the called address specified in the call packet sent from this PVC end point. The value may contain up to 15 digits (digits 0..9). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclFraPvcSubscriberNumber 2.1.866.20.1.20.13.3.1.6
The value of this object is the SB number added to the DNICZO of the equipment to make the calling address in a call sent from this PVC end point. The value must contain 4 digits (digits 0..9). The default value is 'FF FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9999  

fclFraPvcCallDirection 2.1.866.20.1.20.13.3.1.7
The value of this object defines the mode used to establish the X25 VC between this PVC end point and the remote one on the other side of the X25 network. The authorized values are 'calling' (the caller is this PVC end point), 'called' (the caller is the remote PVC end point), 'auto' (automatic choise between 'calling' and 'called'). The default value is 'auto'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER calling(1), called(2), auto(3)  

fclFraPvcEncapsulation 2.1.866.20.1.20.13.3.1.8
The value of this object defines how FR frames are transported in the X25 VC between this PVC end point and the remote one on the other side of the X25 network. The authorized values are 'none' (each FR frame is put in one X25 packet without any particular treatment), 'fastSelect' (Fast select is requested in the call packet), 'fastSelect-frHeader' (Fast select is requested in the call packet, the FR header is also transported), 'fastSelect-frHeader-grouping' (Fast select is requested in the call packet, the FR header is also transported, several FR frames may be grouped in only one X25 packet). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), fastSelect(2), fastSelect-frHeader(3), fastSelect-frHeader-grouping(4)  

fclFraPvcMinRecallTimer 2.1.866.20.1.20.13.3.1.10
The value of this object specifies the minimum recall time (in seconds) between two successive calls. The authorized values are '0..990' by step of 10. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclFraPvcInactivityTimer 2.1.866.20.1.20.13.3.1.11
The value of this object is the inactivity time in seconds.............. The possible values are : '0..2540'. This clearing mechanism is enabled or disabled on the logical port (see fclFraLpInactivityCheckDelay). The default value is '30'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2540  

fclHdlcAccessLogPort 2.1.866.20.1.20.14
OBJECT IDENTIFIER    

fclHdlcLogPortTable 2.1.866.20.1.20.14.1
This table defines the general parameters of HDLC (High-level Data Link Control) access logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclHdlcLogPortEntry

fclHdlcLogPortEntry 2.1.866.20.1.20.14.1.1
An entry of fclHdlcLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclHdlcLogPortEntry  

fclHdlcLpLogPortId 2.1.866.20.1.20.14.1.1.1
The value of this object identifies one and only one HDLC (High-level Data Link Control) access logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclHdlcLpInterfaceId 2.1.866.20.1.20.14.1.1.2
The value of this object identifies the line interface used by this HDLC logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..181  

fclHdlcLpCrcTransport 2.1.866.20.1.20.14.1.1.3
The value of this object indicates whether the CRC (Cyclic Redundancy Check) is transported or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(1)  

fclHdlcLpGroupingThreshold 2.1.866.20.1.20.14.1.1.5
The value of this object is the input resource threshold over which several input frames coming from this HDLC logical port are grouped in a single X25 packet. See fclHdlcAutoEncapsulation to enable this grouping. The possible values are : '1..97'. The thresholds must be set as following : fclHdlcLpGroupingThreshold < fclHdlcLpAllDiscardThreshold. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..97  

fclHdlcLpAllDiscardThreshold 2.1.866.20.1.20.14.1.1.8
The value of this object is the input resource threshold over which all input frames are discarded (i.e. : not sent accross the network). The possible values are : '4..100'. The thresholds must be set as following : fclHdlcLpGroupingThreshold < fclHdlcLpAllDiscardThreshold. The default value is '20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..100  

fclHdlcLpX25InterframeFlagCount 2.1.866.20.1.20.14.1.1.9
The value of this object is the number of interframe flags (it concerns the framing aspects of link access procedures of X25 and not the fact to put several frames coming from this HDLC logical port in a single X25 packet). The possible values are : '1..15'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclHdlcLpInactivityCheckDelay 2.1.866.20.1.20.14.1.1.10
The value of this object is the inactivity check delay in minutes.............. The possible values are : '0..254'. The value '0' disables this clearing mechanism. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..254  

fclHdlcLpCompression 2.1.866.20.1.20.14.1.1.20
The value of this object indicates the compression enabling for each direction. The authorized values are : off : no compression, networkToSubscriber : compression of the flow from the remote peer to the equipment, subscriberToNetwork : compression of the flow from the equipment to the remote peer, bothway : compression of the two flows from and to the equipment. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), networkToSubscriber(2), subscriberToNetwork(3), bothway(4)  

fclHdlcLpCompressNegotiation 2.1.866.20.1.20.14.1.1.21
The value of this object indicates whether the compression facility is negociated or not and, if negociated, the optional/obligatory status. The authorized values are : off' :no negociation, onOptionalCompression : negociation but compression is optional, onMandatoryCompression : negociation and compression is mandatory. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onOptionalCompression(2), onMandatoryCompression(3)  

fclHdlcLpCompressScrambling 2.1.866.20.1.20.14.1.1.22
The value of this object indicates, when the compression is active, whether the scrambling is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclHdlcLpCompressMultiPacketsTimer 2.1.866.20.1.20.14.1.1.23
The value of this object defines the maximum waiting time, in milliseconds by steps of 100 milliseconds , which, if there is not another packet to compress, the packet of compressed packets is sent beyond (this permits to reduce the number of packets transmitted to the remote peer). The authorized values are '0..1500'. '0' means no packets grouping (i. e. : each packet is individually compressed and sent). The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

fclHdlcLpReliableVc 2.1.866.20.1.20.14.1.1.24
The value of this object is used to enable the Reliable Virtual Circuit service. The authorized values are : off : no RVC, the VCs are considered as normal VCs, no particular processing, clear : RVCs are not allowed for the subscriber, each attempt to establish a RVC provokes a clear of the connection, subscribe : all calls transmitted by the subscriber establish RVCs, it is also possible to receive calls with RVC option, check : for a link to a subscriber : when a call with RVC option is received, a RVC is established for a link to a network : the RVC option is ignored when it is present in a call sent by a local subscriber, the connection is cleared when the RVC option is present in a call sent by the network. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(3), subscribe(2), check(4)  

fclHdlcLpCos 2.1.866.20.1.20.14.1.1.30
COS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr-rt(2), vbr(1)  

fclHdlcLpCir 2.1.866.20.1.20.14.1.1.31
Entrant CIR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 600..2048000  

fclHdlcLpMinCir 2.1.866.20.1.20.14.1.1.32
Entrant CIR mini
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclHdlcAutoCallTable 2.1.866.20.1.20.14.2
This table contains the HDLC logical ports for which a call is automatically sent when the operational state of this LP becomes 'up'. For each LP this table defines the addres of the called remote peer and the different parameters of the call processing.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclHdlcAutoCallEntry

fclHdlcAutoCallEntry 2.1.866.20.1.20.14.2.1
An entry of fclHdlcAutoCallTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclHdlcAutoCallEntry  

fclHdlcAutoLogPortId 2.1.866.20.1.20.14.2.1.1
The value of this object identifies one and only one HDLC logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclHdlcAutoCalledAddr 2.1.866.20.1.20.14.2.1.5
The value of this object is the X121 address of the called remote peer. This value is the called address specified in the call packet sent from this logical port. The value may contain up to 15 digits (digits 0..9). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclHdlcAutoSubscriberNumber 2.1.866.20.1.20.14.2.1.6
The value of this object is the SB number added to the DNICZO of the equipment to make the calling address in a call sent from this HDLC logical port. The value must contain 2 digits (digits 0..9). The default value is 'FF FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

fclHdlcAutoCallDirection 2.1.866.20.1.20.14.2.1.7
The value of this object defines the mode used to establish the X25 VC between this HDLC logical port and the remote one on the other side of the network. The authorized values are 'calling' (the caller is this HDLC logical port), 'called' (the caller is this remote HDLC logical port), 'auto' (automatic choise between 'calling' and 'called'). The default value is 'auto'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER calling(1), called(2), auto(3)  

fclHdlcAutoEncapsulation 2.1.866.20.1.20.14.2.1.8
The value of this object defines how HDLC frames are transported in the X25 VC between this HDLC logical port and the remote one on the other side of the network. The authorized values are 'none' (each FR frame is put in one packet without any particular treatment), 'fastSelect' (Fast select is requested in the call packet), 'fastSelect-frHeader' (Fast select is requested in the call packet, the FR header is also transported), 'fastSelect-frHeader-grouping' (Fast select is requested in the call packet, the FR header is also transported, several FR frames may be grouped in only one packet). The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), fastSelect(2), fastSelect-grouping(4)  

fclHdlcAutoMinRecallTimer 2.1.866.20.1.20.14.2.1.10
The value of this object specifies the minimum recall time (in seconds) between two successive calls. The authorized values are '0..990' by step of 10. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclHdlcAutoInactivityTimer 2.1.866.20.1.20.14.2.1.11
The value of this object is the inactivity time in seconds.............. The possible values are : '0..2540'. See fclHdlcLpInactivityCheckDelay to enable or disable this clearing. The default value is '30'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2540  

fclSdlcLogPort 2.1.866.20.1.20.15
OBJECT IDENTIFIER    

fclSdlcLogPortTable 2.1.866.20.1.20.15.1
This table defines the general parameters of SDLC (Synchronous Data Link Control) access logical ports. These SDLC logical ports are used in SNA (Systems Network Architecture) to cross X25 or Frame Relay networks.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclSdlcLogPortEntry

fclSdlcLogPortEntry 2.1.866.20.1.20.15.1.1
An entry of fclSdlcLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclSdlcLogPortEntry  

fclSdlcLpLogPortId 2.1.866.20.1.20.15.1.1.1
The value of this object identifies one and only one SDLC (Synchronous Data Link Control) access logical port in SNA (Systems Network Architecture). The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclSdlcLpInterfaceId 2.1.866.20.1.20.15.1.1.2
The value of this object identifies the line interface used by this SDLC logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclSdlcLpPhysicalUnitType 2.1.866.20.1.20.15.1.1.3
The value of this object indicates the type of the physical unit(s) which are in front of this SDLC logical port. The PU may be 'primary' or 'secondary'. Primary PUs poll secondary Pus in a predetermined order and then secondaries transmit if they have outgoing data. The equipment acts as a primary PU in front of secondaries PU and, on the other side, it acts as secondaries PU in front of a primary PU. The default value is 'secondary' (so the equipment acts as primary PU).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER primary(18), secondary(17)  

fclSdlcLpSubscriberNumber 2.1.866.20.1.20.15.1.1.4
The value of this object is the SB number added to the DNICZO of the equipment to make the calling address in a call sent from this logical port. The value must contain 2 digits (digits 0..9). The default value is 'FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclSdlcLpBitEncoding 2.1.866.20.1.20.15.1.1.5
The value of this object indicates whether the coding format is NRZ (Non Return to Zero) or NRZI (Non Return to Zero Inverted) The default value is 'nrz'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nrz(1), nrzInverse(2)  

fclSdlcLpUnknownPackets 2.1.866.20.1.20.15.1.1.6
The value of this object indicates, when the equipment receives an unknown packet on this logical port, whether it clears the WAN connection or it deletes this packet (i.e. it does not transmit this packet over the network). The default value is 'nrz'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), delete(2)  

fclSdlcLpLogicalLinkProtocol 2.1.866.20.1.20.15.1.1.7
The value of this object indicates which transport protocol is used over the network. QLLC (...) or PSH (...) may be used. The default value is 'qllc'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER qllc(1), psh(2)  

fclSdlcLpPacketSize 2.1.866.20.1.20.15.1.1.8
The value of this object indicates the packet size used across the network. When PSH is used as transport protocol the packet size must be 128 or 256 octets. The default value is 128 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12)  

fclSdlcLpWindowSize 2.1.866.20.1.20.15.1.1.9
The value of this object indicates the window size used across the network. The authorized values are '1..7'. The default value is '7'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclSdlcLpCompression 2.1.866.20.1.20.15.1.1.20
The value of this object indicates the compression enabling for each direction. The authorized values are : off : no compression, networkToSubscriber : compression of the flow from the remote peer to the equipment, subscriberToNetwork : compression of the flow from the equipment to the remote peer, bothway : compression of the two flows from and to the equipment. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), networkToSubscriber(2), subscriberToNetwork(3), bothway(4)  

fclSdlcLpCompressNegotiation 2.1.866.20.1.20.15.1.1.21
The value of this object indicates whether the compression facility is negociated or not and, if negociated, the optional/obligatory status. The authorized values are : off' :no negociation, onOptionalCompression : negociation but compression is optional, onMandatoryCompression : negociation and compression is mandatory. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onOptionalCompression(2), onMandatoryCompression(3)  

fclSdlcLpCompressScrambling 2.1.866.20.1.20.15.1.1.22
The value of this object indicates, when the compression is active, whether the scrambling is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclSdlcLpCompressMultiPacketsTimer 2.1.866.20.1.20.15.1.1.23
The value of this object defines the maximum waiting time, in milliseconds by steps of 100 milliseconds , which, if there is not another packet to compress, the packet of compressed packets is sent beyond (this permits to reduce the number of packets transmitted to the remote peer). The authorized values are '0..1500'. '0' means no packets grouping (i. e. : each packet is individually compressed and sent). The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

fclSdlcLpReliableVc 2.1.866.20.1.20.15.1.1.24
The value of this object is used to enable the Reliable Virtual Circuit service. The authorized values are : off : no RVC, the VCs are considered as normal VCs, no particular processing, clear : RVCs are not allowed for the subscriber, each attempt to establish a RVC provokes a clear of the connection, subscribe : all calls transmitted by the subscriber establish RVCs, it is also possible to receive calls with RVC option, check : for a link to a subscriber : when a call with RVC option is received, a RVC is established for a link to a network : the RVC option is ignored when it is present in a call sent by a local subscriber, the connection is cleared when the RVC option is present in a call sent by the network. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(3), subscribe(2), check(4)  

fclSdlcLpCos 2.1.866.20.1.20.15.1.1.30
COS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1)  

fclSdlcLpCir 2.1.866.20.1.20.15.1.1.31
Entrant CIR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 600..2048000  

fclSdlcLpMinCir 2.1.866.20.1.20.15.1.1.32
Entrant CIR mini
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclSdlcLpBe 2.1.866.20.1.20.15.1.1.33
Entrant BE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclSdlcPrimaryPuLogPort 2.1.866.20.1.20.15.2
OBJECT IDENTIFIER    

fclSdlcPriLogPortTable 2.1.866.20.1.20.15.2.1
This table defines the parameters of SDLC access logical ports which are in front of primaries Physical Units.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclSdlcPriLogPortEntry

fclSdlcPriLogPortEntry 2.1.866.20.1.20.15.2.1.1
An entry of fclSdlcPriLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclSdlcPriLogPortEntry  

fclSdlcPriLpLogPortId 2.1.866.20.1.20.15.2.1.1.1
The value of this object identifies one and only one SDLC access logical port which is in front of primaries Physical Units. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclSdlcPriLpLinkType 2.1.866.20.1.20.15.2.1.1.2
The value of this object indicates which kind of link is estblished over the network. In this description the primary PU in front of this logical port is said 'local', the secondary PU on the other side of the network is said 'remote'. The values are expressed with the format 'local-remote' : pu4-pu4 : PU 4 to PU 4, pu4-pu21 PU 4 to PU 2.1, pu4-pu20 : PU 4 to PU 2.0, pu21-pu21 : PU 2.1 to PU 2.1, nixd-pu20 : Nixdorf PU to PU 2.0, rwsi-pu20 : RWSI to PU 2.0. The default value is 'pu4-pu20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pu4-pu4(25), pu4-pu21(20), pu4-pu20(16), pu21-pu21(22), nixd-pu20(27), rwsi-pu20(30)  

fclSdlcPriLpRemPuIdentification 2.1.866.20.1.20.15.2.1.1.3
The value of this object indicates whether the remote secondary PU is identified by a proprietary way or by using the called address field of call packets. The default value is 'proprietary'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER proprietary(1), calledAddr(2)  

fclSdlcPriLpPollingGroupResponse 2.1.866.20.1.20.15.2.1.1.4
The value of this object indicates whether the equipment answers to the polling group when this feature is used by the local primary PU as a normal secondary PU should do. The address used by this polling group is defined in fclSdlcPriLpPollingGroupAddress. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclSdlcPriLpPollingGroupAddress 2.1.866.20.1.20.15.2.1.1.5
The value of this object defines the address used by the polling group (if the equipment must answer according to fclSdlcPriLpPollingGroupResponse). The value must contain 2 digits (digits 0..F). The default value is 'FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclSdlcPriClusterTable 2.1.866.20.1.20.15.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclSdlcPriClusterEntry

fclSdlcPriClusterEntry 2.1.866.20.1.20.15.2.2.1
An entry of fclSdlcPriClusterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclSdlcPriClusterEntry  

fclSdlcPriClusterLogPortId 2.1.866.20.1.20.15.2.2.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclSdlcPriClusterAddress 2.1.866.20.1.20.15.2.2.1.2
Adresse du cluster
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclSdlcPriClusterStatus 2.1.866.20.1.20.15.2.2.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclSdlcPriClusterRemPu2CalledAddr 2.1.866.20.1.20.15.2.2.1.5
Adresse X121 si identification PU2 distant par adresse appelee
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclSdlcSecondaryPuLogPort 2.1.866.20.1.20.15.3
OBJECT IDENTIFIER    

fclSdlcSecLogPortTable 2.1.866.20.1.20.15.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclSdlcSecLogPortEntry

fclSdlcSecLogPortEntry 2.1.866.20.1.20.15.3.1.1
An entry of fclSdlcSecLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclSdlcSecLogPortEntry  

fclSdlcSecLpLogPortId 2.1.866.20.1.20.15.3.1.1.1
The value of this object identifies one and only one SDLC access logical port which is in front of primaries Physical Units. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclSdlcSecLpLinkType 2.1.866.20.1.20.15.3.1.1.2
The value of this object indicates which kind of link is estblished over the network. In this description the secondary PU in front of this logical port is said 'local', the primary PU on the other side of the network is said 'remote'. The values are expressed with the format 'local-remote' : pu4-pu4 : PU 4 to PU 4, pu21-pu4 PU 2.1 to PU 4, pu21-pu21 : PU 2.1 to PU 2.1, pu20-pu4 : PU 2.0 to PU 4, pu20-nixd : PU 2.0 to Nixdorf PU, pu20-rwsi : PU 2.0 to RWSI. terminal to pu4. The default value is 'pu20-pu4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pu4-pu4(26), pu21-pu4(21), pu21-pu21(23), pu20-pu4(17), pu20-nixd(28), pu20-rwsi(31), terminal-pu4(34)  

fclSdlcSecLpRemPuIdentification 2.1.866.20.1.20.15.3.1.1.3
The value of this object indicates whether the remote secondary PU is identified by a proprietary way or by using the called address field of call packets. The default value is 'proprietary'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER proprietary(1), calledAddr(2)  

fclSdlcSecLpT1AcknowledgeTimer 2.1.866.20.1.20.15.3.1.1.4
T1 Reply timer. A SDLC link-station uses T1 to detect a failure to receive a required acknowlegment or response. T1 runs when there are acknowlegments outstanding, it is reset when acknowlegments are received.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 200..25000  

fclSdlcSecLpN2RetryCount 2.1.866.20.1.20.15.3.1.1.5
The maximum number of transmissions. If the reply timer expires for whatever reason, an S-frame with poll bit set is sent to sollicit a response from remote SDLC link-station. If there is still no response after N2 retry, the link is deemed to be inoperative.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..250  

fclSdlcSecLpCallRetryCount 2.1.866.20.1.20.15.3.1.1.6
The maximum number of calls. If the call confirm is not received, the network layer will repeat a call packet. If there is still no response after n calls, the network layer will then start a slow call.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

fclSdlcSecLpPollingTimer 2.1.866.20.1.20.15.3.1.1.10
Timer between two polling of all stations in a list.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..12800  

fclSdlcSecLpPollingMaxCount 2.1.866.20.1.20.15.3.1.1.11
Number of polling counts before to poll the station with SNRM
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclSdlcSecClusterTable 2.1.866.20.1.20.15.3.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclSdlcSecClusterEntry

fclSdlcSecClusterEntry 2.1.866.20.1.20.15.3.2.1
An entry of fclSdlcSecClusterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclSdlcSecClusterEntry  

fclSdlcSecClusterLogPortId 2.1.866.20.1.20.15.3.2.1.1
The value of this object identifies one and only one SDLC access logical port which is in front of primaries Physical Units. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclSdlcSecClusterAddress 2.1.866.20.1.20.15.3.2.1.2
This is the poll address of the controller. You must make sure this address matches the one assignedto the attached controller. Range is '01 to FF'
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclSdlcSecClusterStatus 2.1.866.20.1.20.15.3.2.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclSdlcSecClusterCalledAddr 2.1.866.20.1.20.15.3.2.1.5
Called X121 address. X121 Address of the corresponding Hpad element.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclSdlcSecClusterFacility 2.1.866.20.1.20.15.3.2.1.6
The value of this object indicates the X25 call packet facility. The possible values are : none : no facility in the call packet, reverseCharging : Reverse Charging, cug : Closed User Group, reverseCharging -cug : Closed User Group, Reverse Charging. The default value is 'none'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), reverseCharging(2), cug(3), reverseCharging-cug(4), throughputClass(5)  

fclSdlcSecClusterFacThroughputClass 2.1.866.20.1.20.15.3.2.1.7
Throughput Class
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclSdlcSecClusterMinRecallTimer 2.1.866.20.1.20.15.3.2.1.10
Slow call timer
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclSdlcSecClusterRemPvcLogChannel 2.1.866.20.1.20.15.3.2.1.11
PVC number
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclSdlcSecClusterXidStringResponse 2.1.866.20.1.20.15.3.2.1.12
This field enables you to assign a PU XID. The unit uses XID's to establish and negociate PU application session. If the PU cannot respond to an XID request from the Host, the unit uses this assigned XID value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

fclSdlcSecClusterCos 2.1.866.20.1.20.15.3.2.1.20
COS Class Of Service VBR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1), vbr-rt(2)  

fclSdlcSecClusterCir 2.1.866.20.1.20.15.3.2.1.21
CIR Committed information Rate is the maximum number of bits per seconds which an end station can transmit into the network . This is the access rate of the user-network interface and it is limited by the line speed of the user-network connection and established by subscription.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclSdlcSecClusterCirmin 2.1.866.20.1.20.15.3.2.1.22
CIRmin If the end station is informed about the congestion of the network, this is the minimum CIR that the end station can transmit into the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclSdlcSecClusterBc 2.1.866.20.1.20.15.3.2.1.23
Bc The Committed Burst Size is a measure for the volume of data for which the network will garantee message delivery under normal conditions. It is measured during the committed rate measurement interval (Tc).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclSdlcSecClusterBe 2.1.866.20.1.20.15.3.2.1.24
Be The Excess Burst Size is the maximum amount of uncommitted data in access of Bc that the network will attemp to deliver during a time interval (Tc). End stations are allowed to transmit data in excess of the committed burst rate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclVipLogPort 2.1.866.20.1.20.16
OBJECT IDENTIFIER    

fclVipLogPortTable 2.1.866.20.1.20.16.1
This table defines the general parameters of VIP (Visual Information Projection) access logical ports. These VIP logical ports are used in HONEYWELL -BULL systems to cross X25 or Frame Relay networks
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclVipLogPortEntry

fclVipLogPortEntry 2.1.866.20.1.20.16.1.1
An entry of fclVipLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclVipLogPortEntry  

fclVipLpLogPortId 2.1.866.20.1.20.16.1.1.1
The value of this object identifies one and only one VIP(Visual Information Projection) access logical port in BULL network architecture. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclVipLpInterfaceId 2.1.866.20.1.20.16.1.1.2
The value of this object identifies the line interface used by this VIP logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclVipLpEmulationType 2.1.866.20.1.20.16.1.1.3
The value of this object indicates the type of unit which are in front of this VIP logical port. The unit may be 'Host' or 'Cluster'. Host units poll cluster units in a predetermined order and then clusters transmit if they have outgoing data. The COMPAC equipment acts as a Cluster in front of a host(HPAD emulation) and, on the other side, it acts as a host in front of a cluster(TPAD emulation). The TPAD always originates the link circuit request .The HPAD is waiting for the link circuit indication. The default value is 'HPAD'(so the equipment acts as Cluster).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER tpad(50), hpad(51)  

fclVipLpResponseSurveyPollingTimer 2.1.866.20.1.20.16.1.1.8
Supervision line watchdog. If this timeout matures, the line is considered as beeing out of order. The default value is 300ms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25000  

fclVipLpScreenRetryTimer 2.1.866.20.1.20.16.1.1.9
Value of screen message transmission Time Out. The default value is '10' s
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fclVipLpPrinterRetryTimer 2.1.866.20.1.20.16.1.1.10
Value of printer message retransmission Time Out. The default value is '70' s
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fclVipLpMessageRetryNumber 2.1.866.20.1.20.16.1.1.11
Number of message retransmissions. The default value is '5'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclVipLpPrinterMessagesManagement 2.1.866.20.1.20.16.1.1.12
'Local management' or 'transparency'of printer messages. Local management It is the standard functionning. When a printer message is received from the HOST , it is not immediateley aknowledged by the COMPAC HPAD.It will be acknowledged when the fclVipLpHosPrinterRetryTimer time out elapses. Transparency. It is an end to end aknowlegement, the printer aknowlege is conveyed through the network(transparency). The default value is 'local management'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER local(1), transparent(2)  

fclVipHostPadLogPort 2.1.866.20.1.20.16.2
OBJECT IDENTIFIER    

fclVipHosLogPortTable 2.1.866.20.1.20.16.2.1
This table defines the parameters of VIP access logical ports which are in front of Host Units
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclVipHosLogPortEntry

fclVipHosLogPortEntry 2.1.866.20.1.20.16.2.1.1
An entry of fclVipHosLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclVipHosLogPortEntry  

fclVipHosLpLogPortId 2.1.866.20.1.20.16.2.1.1.1
The value of this object identifies one and only one VIP access logical port which is in front of a HOST. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclVipHosLpWaitTimeOutForPrinter 2.1.866.20.1.20.16.2.1.1.2
Value of inter-polling time-out for printer. The default value is '300' ms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..12800  

fclVipHosLpRepAEot 2.1.866.20.1.20.16.2.1.1.5
EOT response or not from the HPAD on polls of the HOST and in case the virtual circuit with the TPAD has not been established. The default value is 'EOT response on the polls'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclVipHosLpFtbcc 2.1.866.20.1.20.16.2.1.1.6
Special treatment or not for the 'PENQ (printer Enquiry)sequence'(seen with customer FTBCC ITALY). The default value is 'no special treatement'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclVipHosElementTable 2.1.866.20.1.20.16.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclVipHosElementEntry

fclVipHosElementEntry 2.1.866.20.1.20.16.2.2.1
An entry of fclVipHosElementTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclVipHosElementEntry  

fclVipHosElementId 2.1.866.20.1.20.16.2.2.1.1
Ident Element. The value of this object identifies one identificable addressable entity. The possible values are : '0..200'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..200  

fclVipHosElemStatus 2.1.866.20.1.20.16.2.2.1.2
Status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclVipHosElemLogPortId 2.1.866.20.1.20.16.2.2.1.3
LpId. Logical Port Identifier.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..181  

fclVipHosElemType 2.1.866.20.1.20.16.2.2.1.4
Element Type. Cluster or Isolated Station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cluster(1), isolatedstation(2)  

fclVipHosElemAddress 2.1.866.20.1.20.16.2.2.1.5
Element Address. Vip Address of The Entity Between '0' and '31'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

fclVipHosStationTable 2.1.866.20.1.20.16.2.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclVipHosStationEntry

fclVipHosStationEntry 2.1.866.20.1.20.16.2.3.1
An entry of fclVipHosStationTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclVipHosStationEntry  

fclVipHosStatElementId 2.1.866.20.1.20.16.2.3.1.1
Ident Element.The value of this object identifies one identificable addressable entity. The possible values are : '0..200'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..200  

fclVipHosStatStationAddress 2.1.866.20.1.20.16.2.3.1.2
Station Address. Vip Address of the cluster defined in the previous table (case when element type=Cluster).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

fclVipHosStatStatus 2.1.866.20.1.20.16.2.3.1.3
Status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclVipClusterLogPort 2.1.866.20.1.20.16.3
OBJECT IDENTIFIER    

fclVipCluLogPortTable 2.1.866.20.1.20.16.3.1
This table defines the parameters of VIP access logical ports which are in front of Cluster Units
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclVipCluLogPortEntry

fclVipCluLogPortEntry 2.1.866.20.1.20.16.3.1.1
An entry of fclVipCluLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclVipCluLogPortEntry  

fclVipCluLpLogPortId 2.1.866.20.1.20.16.3.1.1.1
The value of this object identifies one and only one VIP access logical port which is in front of a HOST. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclVipCluLpPollingTimer 2.1.866.20.1.20.16.3.1.1.2
Value of interpolling wait time-out (retransmission of polling frame on expiry of time out).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..12800  

fclVipCluLpFailedPollingMaxNumber 2.1.866.20.1.20.16.3.1.1.3
Maximum number of unanswered polls The default value is '6'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..250  

fclVipCluLpPollingTypeAfterSelect 2.1.866.20.1.20.16.3.1.1.8
Polling Type after select Station polling. After a select the Tpad sends a station poll in order to directly receive from it an immediate aknowledgement . Cluster polling. After a select , the Tpad sends a cluster select. Although less efficient it is sometimes used in certain configurations. The default value is 'station poll'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER stationPoll(1), clusterPoll(2)  

fclVipCluLpScreenKeepTimer 2.1.866.20.1.20.16.3.1.1.9
Screen message Blocking Duration of the blocking of the screen flow .After reception of a screen message , transmitted by a VIP station ,the message flow from that station to the screen is blocked .The station is released when a screen message is received from the Host or when the protection time-out expires. The default value is no blocking.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2550  

fclVipCluElementTable 2.1.866.20.1.20.16.3.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclVipCluElementEntry

fclVipCluElementEntry 2.1.866.20.1.20.16.3.2.1
An entry of fclVipCluElementTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclVipCluElementEntry  

fclVipCluElementId 2.1.866.20.1.20.16.3.2.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..200  

fclVipCluElemStatus 2.1.866.20.1.20.16.3.2.1.2
Status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclVipCluElemLogPortId 2.1.866.20.1.20.16.3.2.1.3
LpId. Logical Port Identifier
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..181  

fclVipCluElemType 2.1.866.20.1.20.16.3.2.1.4
Element Type. Cluster or Isolated Station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cluster(1), isolatedstation(2)  

fclVipCluElemAddress 2.1.866.20.1.20.16.3.2.1.5
Element Address. Vip Adress of the Entity between '0' and '31'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

fclVipCluElemCalledAddr 2.1.866.20.1.20.16.3.2.1.10
Called X121 address. X121 Address of the corresponding Hpad element.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclVipCluElemMinRecallTimer 2.1.866.20.1.20.16.3.2.1.11
Call Retransmission timing value. If a call fails, this timer is started. When it matures, an other call is made.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclVipCluStationTable 2.1.866.20.1.20.16.3.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclVipCluStationEntry

fclVipCluStationEntry 2.1.866.20.1.20.16.3.3.1
An entry of fclVipCluStationTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclVipCluStationEntry  

fclVipCluStatElementId 2.1.866.20.1.20.16.3.3.1.1
Ident Element. The value of this objetc identifies one identifiable and addressable entity. The possible values are : '0..200'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..200  

fclVipCluStatStationAddress 2.1.866.20.1.20.16.3.3.1.2
Station Address. Vip adress of the cluster defined in the previuos table (case when element type=cluster).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

fclVipCluStatStatus 2.1.866.20.1.20.16.3.3.1.3
Status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclBsc3270LogPort 2.1.866.20.1.20.17
OBJECT IDENTIFIER    

fclB3270LogPortTable 2.1.866.20.1.20.17.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclB3270LogPortEntry

fclB3270LogPortEntry 2.1.866.20.1.20.17.1.1
An entry of fclB3270LogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclB3270LogPortEntry  

fclB3270LpLogPortId 2.1.866.20.1.20.17.1.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclB3270LpInterfaceId 2.1.866.20.1.20.17.1.1.2
IF Id (type ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclB3270LpEmulationType 2.1.866.20.1.20.17.1.1.3
Type d'emulation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER tpad(60), hpad(61)  

fclB3270LpCodingParityType 2.1.866.20.1.20.17.1.1.4
Type de codage parite
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ebcdic(1), asciioddparity(2)  

fclB3270LpNoAnswerWatchDog 2.1.866.20.1.20.17.1.1.5
Temporisation de non reponse
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25000  

fclB3270LpMessageRetryNumber 2.1.866.20.1.20.17.1.1.6
Nombre de reemission de message
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fclB3270HostPadLogPort 2.1.866.20.1.20.17.2
OBJECT IDENTIFIER    

fclB3270HosLogPortTable 2.1.866.20.1.20.17.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclB3270HosLogPortEntry

fclB3270HosLogPortEntry 2.1.866.20.1.20.17.2.1.1
An entry of fclB3270HosLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclB3270HosLogPortEntry  

fclB3270HosLpLogPortId 2.1.866.20.1.20.17.2.1.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclB3270HosLpLineWatchDog 2.1.866.20.1.20.17.2.1.1.2
Tempo de surveillance de ligne
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fclB3270HosLpWackTransmission 2.1.866.20.1.20.17.2.1.1.3
Emission WACK
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclB3270HosLpAnswerToPolling 2.1.866.20.1.20.17.2.1.1.4
Reponse au poll systematique
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER always(1), onlinkup(2)  

fclB3270HosClusterTable 2.1.866.20.1.20.17.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclB3270HosClusterEntry

fclB3270HosClusterEntry 2.1.866.20.1.20.17.2.2.1
An entry of fclB3270HosClusterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclB3270HosClusterEntry  

fclB3270HosClusterLogPortId 2.1.866.20.1.20.17.2.2.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclB3270HosClusterCluAdd 2.1.866.20.1.20.17.2.2.1.2
Adresse du cluster
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

fclB3270HosClusterStaAdd 2.1.866.20.1.20.17.2.2.1.3
Adresse station
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

fclB3270HosClusterStatus 2.1.866.20.1.20.17.2.2.1.4
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclB3270ClusterLogPort 2.1.866.20.1.20.17.3
OBJECT IDENTIFIER    

fclB3270CluLogPortTable 2.1.866.20.1.20.17.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclB3270CluLogPortEntry

fclB3270CluLogPortEntry 2.1.866.20.1.20.17.3.1.1
An entry of fclB3270CluLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclB3270CluLogPortEntry  

fclB3270CluLpLogPortId 2.1.866.20.1.20.17.3.1.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclB3270CluLpPollingTimer 2.1.866.20.1.20.17.3.1.1.10
Temporisation d'interpolling
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25000  

fclB3270CluLpMaxNumberOfUnwPolls 2.1.866.20.1.20.17.3.1.1.11
Nombre maximum de non reponse au polling
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fclB3270CluLpReconnectionType 2.1.866.20.1.20.17.3.1.1.12
Type de reconnexion
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER automatic(1), ondata(2)  

fclB3270CluClusterTable 2.1.866.20.1.20.17.3.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclB3270CluClusterEntry

fclB3270CluClusterEntry 2.1.866.20.1.20.17.3.2.1
An entry of fclB3270CluClusterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclB3270CluClusterEntry  

fclB3270CluClusterLogPortId 2.1.866.20.1.20.17.3.2.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclB3270CluClusterCluAdd 2.1.866.20.1.20.17.3.2.1.2
Adresse du cluster
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

fclB3270CluClusterStaAdd 2.1.866.20.1.20.17.3.2.1.3
Adresse station
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

fclB3270CluClusterStatus 2.1.866.20.1.20.17.3.2.1.4
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclB3270CluCallTable 2.1.866.20.1.20.17.3.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclB3270CluCallEntry

fclB3270CluCallEntry 2.1.866.20.1.20.17.3.3.1
An entry of fclB3270CluCallTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclB3270CluCallEntry  

fclB3270CluCallLogPortId 2.1.866.20.1.20.17.3.3.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclB3270CluCallCluAdd 2.1.866.20.1.20.17.3.3.1.2
Adresse du cluster
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

fclB3270CluCallStatus 2.1.866.20.1.20.17.3.3.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclB3270CluCallCallAddr 2.1.866.20.1.20.17.3.3.1.5
Adresse X121 appelee
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclB3270CluCallMinRecallTimer 2.1.866.20.1.20.17.3.3.1.10
Tempo de retransmission d'appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclBscX780LogPort 2.1.866.20.1.20.18
OBJECT IDENTIFIER    

fclBX780LogPortTable 2.1.866.20.1.20.18.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclBX780LogPortEntry

fclBX780LogPortEntry 2.1.866.20.1.20.18.1.1
An entry of fclBX780LogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclBX780LogPortEntry  

fclBX780LpLogPortId 2.1.866.20.1.20.18.1.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclBX780LpInterfaceId 2.1.866.20.1.20.18.1.1.2
IF Id (type ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclBX780LpProtocolType 2.1.866.20.1.20.18.1.1.3
Type de BSC
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bsc2780(1), bsc3780(2), bsc3780onPSTN(3)  

fclBX780LpCallDirection 2.1.866.20.1.20.18.1.1.4
Mode d'appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER calling(1), called(2)  

fclBX780LpDeconnectTimer 2.1.866.20.1.20.18.1.1.5
Tempo de deconnexion
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2500  

fclBX780LpSurveyTimer 2.1.866.20.1.20.18.1.1.6
Tempo de surveillance
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2500  

fclBX780LpCodingParityType 2.1.866.20.1.20.18.1.1.7
Type de codage parite
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ebcdic(1), asciioddparity(2)  

fclBX780LpEquipementType 2.1.866.20.1.20.18.1.1.8
Type de couple
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER term-term(1), term-cpu(2), cpu-cpu(3), cpu-term(4)  

fclBX780LpENQRetransTimer 2.1.866.20.1.20.18.1.1.9
Tempo de retransmission du ENQ
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25000  

fclBX780LpAuthorAnswerTimer 2.1.866.20.1.20.18.1.1.10
Tempo de reponse auteur
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25000  

fclBX780LpNoAnswerWatchDog 2.1.866.20.1.20.18.1.1.11
Temporisation de non reponse
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25000  

fclBX780LpMessageRetryNumber 2.1.866.20.1.20.18.1.1.12
Nombre de reemission de message
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fclBX780ConnectionTable 2.1.866.20.1.20.18.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclBX780ConnectionEntry

fclBX780ConnectionEntry 2.1.866.20.1.20.18.2.1
An entry of fclBX780ConnectionTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclBX780ConnectionEntry  

fclBX780ConnLogPortId 2.1.866.20.1.20.18.2.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclBX780ConnCalledAddr 2.1.866.20.1.20.18.2.1.2
WAN adresse appelee
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclBX780ConnMinimumRecallTimer 2.1.866.20.1.20.18.2.1.3
Tempo de retransmission d'appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclBX780IdentTable 2.1.866.20.1.20.18.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclBX780IdentEntry

fclBX780IdentEntry 2.1.866.20.1.20.18.3.1
An entry of fclBX780IdentTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclBX780IdentEntry  

fclBX780IdentLogPortId 2.1.866.20.1.20.18.3.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclBX780IdentTermId 2.1.866.20.1.20.18.3.1.2
Ident du terminal
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

fclBX780IdentStatus 2.1.866.20.1.20.18.3.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclBscSctLogPort 2.1.866.20.1.20.19
OBJECT IDENTIFIER    

fclBSctLogPortTable 2.1.866.20.1.20.19.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclBSctLogPortEntry

fclBSctLogPortEntry 2.1.866.20.1.20.19.1.1
An entry of fclBSctLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclBSctLogPortEntry  

fclBSctLpLogPortId 2.1.866.20.1.20.19.1.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclBSctLpInterfaceId 2.1.866.20.1.20.19.1.1.2
IF Id (type ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclBSctLpLinkType 2.1.866.20.1.20.19.1.1.3
Type de liaison
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2), tpc(3)  

fclBSctLpNumberOfSYN 2.1.866.20.1.20.19.1.1.4
Nombre de SYN avant la trame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER trans-of-2-SYN(2), trans-of-4-SYN(4)  

fclBSctLpSignalEnvelope 2.1.866.20.1.20.19.1.1.5
Enveloppe de trame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclBSctLpCodingParityType 2.1.866.20.1.20.19.1.1.6
Type de codage parite
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ebcdic(1), asciioddparity(2)  

fclBSctLpMaxFrameNumberIn 2.1.866.20.1.20.19.1.1.7
Nombre de trame acceptee en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..254  

fclBSctLpUnderrunManagement 2.1.866.20.1.20.19.1.1.8
Gestion de l underrun
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclBSctLpOnePadSuppressed 2.1.866.20.1.20.19.1.1.9
Suppression d un pad
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclBSctConnectionTable 2.1.866.20.1.20.19.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclBSctConnectionEntry

fclBSctConnectionEntry 2.1.866.20.1.20.19.2.1
An entry of fclBSctConnectionTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclBSctConnectionEntry  

fclBSctConnLogPortId 2.1.866.20.1.20.19.2.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclBSctConnCalledAddr 2.1.866.20.1.20.19.2.1.2
WAN adresse appele
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclBSctConnCallDirection 2.1.866.20.1.20.19.2.1.3
Mode d appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER calling(1), called(2), auto(3), datagram(4)  

fclBSctConnSubscriberNumber 2.1.866.20.1.20.19.2.1.4
Numero d'abonne
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9999  

fclBSctConnMinimumRecallTimer 2.1.866.20.1.20.19.2.1.5
Tempo de retransmission d'appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclBSctProtocolDefinition1Table 2.1.866.20.1.20.19.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclBSctProtocolDefinition1Entry

fclBSctProtocolDefinition1Entry 2.1.866.20.1.20.19.3.1
An entry of fclBSctProtocolDefinition1Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclBSctProtocolDefinition1Entry  

fclBSctProtDef1LogPortId 2.1.866.20.1.20.19.3.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclBSctProtDef1PermanentDelimiter1 2.1.866.20.1.20.19.3.1.2
1 e Delimiteur Permanent
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef1PermanentDelimiter2 2.1.866.20.1.20.19.3.1.3
2 e Delimiteur Permanent
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef1PermanentDelimiter3 2.1.866.20.1.20.19.3.1.4
3 e Delimiteur Permanent
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef1PermanentDelimiter4 2.1.866.20.1.20.19.3.1.5
4 e Delimiteur Permanent
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef1PermanentDelimiter5 2.1.866.20.1.20.19.3.1.6
5 e Delimiteur Permanent
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef1StartFrameDelimiter1 2.1.866.20.1.20.19.3.1.7
1 e delimiteur de debut de trame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef1StartFrameDelimiter2 2.1.866.20.1.20.19.3.1.8
2 e delimiteur de debut de trame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef1StartFrameDelimiter3 2.1.866.20.1.20.19.3.1.9
3 e delimiteur de debut de trame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef1NbCharInhibited 2.1.866.20.1.20.19.3.1.10
nombre de caracteres a iniber
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..10  

fclBSctProtDef1StFrDelimiterInhib1 2.1.866.20.1.20.19.3.1.11
1 e delimiteur de debut de trame avec inibition
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef1StFrDelimiterInhib2 2.1.866.20.1.20.19.3.1.12
2 e delimiteur de debut de trame avec inibition
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtocolDefinition2Table 2.1.866.20.1.20.19.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclBSctProtocolDefinition2Entry

fclBSctProtocolDefinition2Entry 2.1.866.20.1.20.19.4.1
An entry of fclBSctProtocolDefinition2Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclBSctProtocolDefinition2Entry  

fclBSctProtDef2LogPortId 2.1.866.20.1.20.19.4.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclBSctProtDef2DataFrameTerminator1 2.1.866.20.1.20.19.4.1.2
1 e Terminateur de trame de donnees
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef2DataFrameTerminator2 2.1.866.20.1.20.19.4.1.3
2 e Terminateur de trame de donnees
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef2DataFrameTerminator3 2.1.866.20.1.20.19.4.1.4
3 e Terminateur de trame de donnees
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef2ControlFrameTerminator1 2.1.866.20.1.20.19.4.1.5
1 e Terminateur de trame de controle
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef2ControlFrameTerminator2 2.1.866.20.1.20.19.4.1.6
2 e Terminateur de trame de controle
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), enq(2), nak(3), eot(4), stx(5), soh(6), etx(7), etb(8), pad(9), ack(10), dle(11), esc(12), bel(13)  

fclBSctProtDef2ACK0 2.1.866.20.1.20.19.4.1.7
ACK0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclBSctProtDef2ACK1 2.1.866.20.1.20.19.4.1.8
ACK1
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclBSctProtDef2WACK 2.1.866.20.1.20.19.4.1.9
WACK
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclBSctProtDef2RVI 2.1.866.20.1.20.19.4.1.10
RVI
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclBSctProtDef2WABT 2.1.866.20.1.20.19.4.1.11
WABT
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclX25SlpAccess 2.1.866.20.1.20.20
OBJECT IDENTIFIER    

fclX25SlpAccessTable 2.1.866.20.1.20.20.1
This table defines the general parameters of X25 SLP (Single Link Protocol) access logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25SlpAccessEntry

fclX25SlpAccessEntry 2.1.866.20.1.20.20.1.1
An entry of fclX25SlpAccessTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25SlpAccessEntry  

fclX25AccLogPortId 2.1.866.20.1.20.20.1.1.1
The value of this object identifies one and only one X25 SLP (Single Link Protocol) access logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25AccInterfaceId 2.1.866.20.1.20.20.1.1.2
The value of this object identifies the line interface used by this X25 access logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25AccConnectionType 2.1.866.20.1.20.20.1.1.3
The value of this object indicates which is the system connected to this X25 access logical port. The possible values are : subscriber : this X25 access logical port logical port is facing to a X25 subscriber, fclX25AccSubscriberNumber is used, fclX25AccPdnLinkAddress is not used, publicNetwork : this logical port is facing to a X25 Public Data Network, fclX25AccSubscriberNumber is not used, fclX25AccPdnLinkAddress is used. The default value is 'subscriber'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER subscriber(1), publicNetwork(2)  

fclX25AccSubscriberNumber 2.1.866.20.1.20.20.1.1.4
The value of this object is the SB number added to the DNICZO of the equipment to make the calling address in a call sent from this X25 access logical port (if fclX25AccConnectionType is set to 'subscriber'). The value must contain 2 digits (digits 0..9). The default value is 'FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclX25AccPdnLinkAddress 2.1.866.20.1.20.20.1.1.5
The value of this object is the X121 address of the equipment on the connected network (if fclX25AccConnectionType is set to 'publicNetwork'). The value may contain up to 15 digits (digits 0..9). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclX25AccX25AccessConfigId 2.1.866.20.1.20.20.1.1.6
The value of this object identifies the X25 access configuration used by this X25 access logical port. This X25 access configuration must be present in fclX25ConfigAccessTable. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25AccIsdnBackupEnabling 2.1.866.20.1.20.20.1.1.7
Secours RNIS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onWhileActivity(2), onWhileLpDown(3), onWhileExcessTraffic(7)  

fclX25AccPstnBackupEnabling 2.1.866.20.1.20.20.1.1.8
Secours RTC
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onWhileActivity(2), onWhileLpDown(3), onWhileExcessTraffic(7)  

fclX25AccPrivateNetTable 2.1.866.20.1.20.20.2
This table defines the X25 access logical ports for which some X25 call packet fields are saved in X25 facility field. The restoration of these field takes place on the other side of the network in a symetric X25 SLP access logical port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25AccPrivateNetEntry

fclX25AccPrivateNetEntry 2.1.866.20.1.20.20.2.1
An entry of fclX25AccPrivateNetTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25AccPrivateNetEntry  

fclX25AccPrivLogPortId 2.1.866.20.1.20.20.2.1.1
The value of this object identifies one and only one X25 access logical port.The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25AccPrivX25FieldsSave 2.1.866.20.1.20.20.2.1.2
The value of this object indicates which X25 call packet fields are saved in X25 facility field for this X25 access logical port. The save operation is made on X25 call packets sent over the network and the restore operation is made on X25 packets received from the network. The possible values are : off : no save/restore procedure, addr : called and calling addresses, addrCug : called and calling addresses, Closed User Group, addrCugRc : called and calling addresses, Closed User Group, Reverse Charging. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), addr(4), addrCug(8), addrCugRc(16)  

fclX25AccPrivX25FieldsChanges 2.1.866.20.1.20.20.2.1.3
The value of this object describes X25 fields modifications. The syntaxe is [value]. There are 3 possible modifications : BF : adds a facility at output, DA : deletes caller's address at input, CE : changes called party address. Example : DA CE 90 40 21 80 BF 70 10 00, DA deletes the calling address, CE 90 40 21 80 changes the called address to 90402180, BF 70 10 00 adds the facility 701000 at output of switch. 25 bytes from 00 to FF must be specified. The first byte contains the number of following useful bytes. The trailing bytes must be set to 'FF'. The equipment configurator does not need this final completion. The default value is 'empty' (first byte set to '00').
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(25)  

fclX25AccPermanentVcTable 2.1.866.20.1.20.20.3
This table defines the X25 PVC (Permananent Virtual Circuits) on X25 Access logical ports. For each PVC this table defines the addres of the called remote peer and the different parameters of the call processing.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25AccPermanentVcEntry

fclX25AccPermanentVcEntry 2.1.866.20.1.20.20.3.1
An entry of fclX25AccPermanentVcTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25AccPermanentVcEntry  

fclX25AccPvcLogPortId 2.1.866.20.1.20.20.3.1.1
The value of this object identifies one and only one X25 Access logical port. This is the logical port this PVC (Permanent Virtual Circuit) is layered onto. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25AccPvcLocalLogChannel 2.1.866.20.1.20.20.3.1.2
The value of this object is equal to the logical channel value for this PVC. The possible values are '0..250'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..250  

fclX25AccPvcStatus 2.1.866.20.1.20.20.3.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25AccPvcCalledAddr 2.1.866.20.1.20.20.3.1.4
The value of this object is the X121 address of the called remote peer PVC. This value is the called address specified in the call packet sent from this PVC. The value may contain up to 15 digits (digits 0..9). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclX25AccPvcRemoteLogChannel 2.1.866.20.1.20.20.3.1.5
The value of this object is equal to the logical channel value for the remote peer PVC. The possible values are '0..250'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclX25AccPvcMinimumRecallTimer 2.1.866.20.1.20.20.3.1.6
The value of this object specifies the minimum recall time (in seconds) between two successive calls. The authorized values are '0..990' by step of 10. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclX25AccPvcCallDirection 2.1.866.20.1.20.20.3.1.7
The value of this object defines the mode used to establish the X25 VC between this PVC and the remote one on the other side of the network. The authorized values are 'calling' (the caller is this PVC), 'called' (the caller is the remote PVC), 'auto' (automatic choise between 'calling' and 'called'). The default value is 'auto'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER calling(1), called(2), auto(3)  

fclX25AccPvcFacility 2.1.866.20.1.20.20.3.1.8
Facilites
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), throughputClass(2)  

fclX25AccPvcFacThroughputClass 2.1.866.20.1.20.20.3.1.9
Classe de debit eventuelle
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclX25AccSwitchOverTable 2.1.866.20.1.20.20.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25AccSwitchOverEntry

fclX25AccSwitchOverEntry 2.1.866.20.1.20.20.4.1
An entry of fclX25AccSwitchOverTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25AccSwitchOverEntry  

fclX25AccSwLogPortId 2.1.866.20.1.20.20.4.1.1
LP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25AccSwMeasureCount 2.1.866.20.1.20.20.4.1.2
Nombre de mesures avant basculement
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..249  

fclX25AccSwSwitchThreshold 2.1.866.20.1.20.20.4.1.3
Seuil haut (en pourcentage)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclX25AccSwSwitchBackThreshold 2.1.866.20.1.20.20.4.1.4
Seuil bas (en pourcentage)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclX25AccIsdnBackupTable 2.1.866.20.1.20.20.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25AccIsdnBackupEntry

fclX25AccIsdnBackupEntry 2.1.866.20.1.20.20.5.1
An entry of fclX25AccIsdnBackupTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25AccIsdnBackupEntry  

fclX25AccIsdnBackLogPortId 2.1.866.20.1.20.20.5.1.1
LP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25AccIsdnBackIsdnInterfaceId 2.1.866.20.1.20.20.5.1.2
IF id (type RNIS)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclX25AccIsdnBackStatus 2.1.866.20.1.20.20.5.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25AccIsdnRemotePeerTable 2.1.866.20.1.20.20.6
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25AccIsdnRemotePeerEntry

fclX25AccIsdnRemotePeerEntry 2.1.866.20.1.20.20.6.1
An entry of fclX25AccIsdnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25AccIsdnRemotePeerEntry  

fclX25AccIsdnRemLogPortId 2.1.866.20.1.20.20.6.1.1
LP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25AccIsdnRemIsdnInterfaceId 2.1.866.20.1.20.20.6.1.2
Interface RNIS distante id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclX25AccIsdnRemStatus 2.1.866.20.1.20.20.6.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25AccIsdnRemX25AccessConfigId 2.1.866.20.1.20.20.6.1.4
Configuration X25 acces id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25AccIsdnRemPriority 2.1.866.20.1.20.20.6.1.5
Priorite
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

fclX25AccIsdnRemCallRetryCount 2.1.866.20.1.20.20.6.1.6
Nb de tentatives appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclX25AccPstnBackupTable 2.1.866.20.1.20.20.7
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25AccPstnBackupEntry

fclX25AccPstnBackupEntry 2.1.866.20.1.20.20.7.1
An entry of fclX25AccPstnBackupTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25AccPstnBackupEntry  

fclX25AccPstnBackLogPortId 2.1.866.20.1.20.20.7.1.1
LP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25AccPstnBackStatus 2.1.866.20.1.20.20.7.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25AccPstnBackInterfaceId 2.1.866.20.1.20.20.7.1.3
IF id (type ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25AccPstnBackPstnNumber 2.1.866.20.1.20.20.7.1.4
Numero RTC
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(14)  

fclX25AccPstnBackX25AccessConfigId 2.1.866.20.1.20.20.7.1.5
Configuration X25 acces id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25InDIsdn 2.1.866.20.1.20.21
OBJECT IDENTIFIER    

fclX25InDIsdnTable 2.1.866.20.1.20.21.1
This table defines the general parameters of X25 SLP (Single Link Protocol) in ISDN D channel access logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25InDIsdnEntry

fclX25InDIsdnEntry 2.1.866.20.1.20.21.1.1
An entry of fclX25InDIsdnTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25InDIsdnEntry  

fclX25InDLogPortId 2.1.866.20.1.20.21.1.1.1
The value of this object identifies one and only one X25 in ISDN D Channel logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25InDIsdnInterfaceId 2.1.866.20.1.20.21.1.1.2
The value of this object identifies the ISDN Basic Rate Interface used by this X25 in ISDN-D logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25InDTei 2.1.866.20.1.20.21.1.1.3
The value of this object defines the TEI (Terminal Endpoint Identifier) used by this X25 in ISDN-D logical port. The authorized values are '1..63'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..63  

fclX25InDBackupEnabling 2.1.866.20.1.20.21.1.1.4
The value of this object defines how this X25 in ISDN-D logical port may be backuped by an ISDN-B channel. The possible values are : off : backup is never enabled, onWhileActivity : when the logical port is DOWN, backup is enabled on reception of a new call and remains active while at least one X25 VC is using this way. When no VC is active, the backup is disabled and the next VC will be established on the logical port (if it is UP obviously). onWhileLpDown : when the logical port is DOWN, backup is enabled on reception of a new call and remains active while the logical port is DOWN. The backup is disabled (meaning clearing of all VCs using this way) when the logical port comes back UP and the next VC will be established on the logical port. onWhileExcessTraffic : when the traffic overtakes the fclX25InDSwSwitchThreshold value the logical port state is marked DOWN (meaning clearing of all VCs), backup is enabled on reception of a new call and remains active while the traffic is overtaking the fclX25InDSwSwitchBackThreshold value. When the traffic does not overtake any more the fclX25InDSwSwitchBackThreshold value, the logical port is marked UP and the backup is disabled (meaning clearing of all VCs using this way) so the next VC will be established on the logical port. This Switch Over mechanism permits to transmit temporay excess traffic which could not be transmitted on the ISDN-D Channel because of an insufficient bandwith (16 kbit/s against 64 kbits/s for an ISDN-B Channel). The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onWhileActivity(2), onWhileLpDown(3), onWhileExcessTraffic(7)  

fclX25InDConnectionType 2.1.866.20.1.20.21.1.1.5
The value of this object indicates which is the system connected to this X25 in ISDN-D logical port. The possible values are : subscriber : this X25 ISDN-D logical port logical port is facing to a X25 subscriber, fclX25InDSubscriberNumber is used, fclX25InDPdnLinkAddress is not used, publicNetwork : this logical port is facing to a X25 Public Data Network, fclX25InDSubscriberNumber is not used, fclX25InDPdnLinkAddress is used. The default value is 'subscriber'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER subscriber(1), publicNetwork(2)  

fclX25InDSubscriberNumber 2.1.866.20.1.20.21.1.1.6
The value of this object is the SB number added to the DNICZO of the equipment to make the calling address in a call sent from this X25 in ISDN-D logical port (if fclX25InDConnectionType is set to 'subscriber'). The value must contain 2 digits (digits 0..9). The default value is 'FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclX25InDPdnLinkAddress 2.1.866.20.1.20.21.1.1.7
The value of this object is the X121 address of the equipment on the connected network (if fclX25InDConnectionType is set to 'publicNetwork'). The value may contain up to 15 digits (digits 0..9). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclX25InDX25AccessConfigId 2.1.866.20.1.20.21.1.1.8
The value of this object identifies the X25 access configuration used by this X25 in ISDN-D logical port. This X25 access configuration must be present in fclX25ConfigAccessTable. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25InDInactivityTimer 2.1.866.20.1.20.21.1.1.9
The value of this object defines the delay in seconds between the clearing of the last X25 VC using this ISDN-D logical port and the clearing of the ISDN connection. The authorized values are '0..250'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclX25InDActiveLinkAtBootTime 2.1.866.20.1.20.21.1.1.10
The value of this object indicates whether the equipment, when it has just started, must establish the ISDN connection or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25InDSwitchOverTable 2.1.866.20.1.20.21.2
This table defines the switch over parameters of X25 in ISDN D channel access logical ports using the switch over mechanism.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25InDSwitchOverEntry

fclX25InDSwitchOverEntry 2.1.866.20.1.20.21.2.1
An entry of fclX25InDSwitchOverTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25InDSwitchOverEntry  

fclX25InDSwLogPortId 2.1.866.20.1.20.21.2.1.1
The value of this object identifies one and only one X25 in ISDN D Channel logical port using the switch over mechanism (fclX25InDBackupEnabling set to 'onWhileExcessTraffic'). The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25InDSwMeasureCount 2.1.866.20.1.20.21.2.1.2
The value of this object is the number of traffic measures before switching. The measure duration is defined by fcwLoadAndTrafficSummingPeriod. The authorized values are '0..249'. The default value is '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..249  

fclX25InDSwSwitchThreshold 2.1.866.20.1.20.21.2.1.3
The value of this object indicates the traffic threshold (in percents of bandwith of the main link of logical port) over which the switch over mechanism is enabled. The authorized values are '0..100'. The default value is '80'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclX25InDSwSwitchBackThreshold 2.1.866.20.1.20.21.2.1.4
The value of this object indicates the traffic threshold (in percents of bandwith of the main link of logical port) under which the switch over mechanism is disabled. The authorized values are '0..100'. The default value is '60'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclX25InDIsdnBackupTable 2.1.866.20.1.20.21.3
This table defines which ISDN Basic Rate Interface may be used by each X25 in ISDN D channel access logical port when enabling backup on ISDN B-Channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25InDIsdnBackupEntry

fclX25InDIsdnBackupEntry 2.1.866.20.1.20.21.3.1
An entry of fclX25InDIsdnBackupTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25InDIsdnBackupEntry  

fclX25InDIsdnBackLogPortId 2.1.866.20.1.20.21.3.1.1
The value of this object identifies one and only one X25 in ISDN D channel access logical port. One X25 X25 in ISDN D channel logical port may use backup with one or several ISDN Basic Rate Interfaces. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25InDIsdnBackIsdnInterfaceId 2.1.866.20.1.20.21.3.1.2
The value of this object identifies one ISDN Basic Rate Interface used by the X25 in ISDN D channel access logical port defined by fclX25InDIsdnBackLogPortId. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclX25InDIsdnBackStatus 2.1.866.20.1.20.21.3.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25InDIsdnRemotePeerTable 2.1.866.20.1.20.21.4
This table defines the ISDN remote systems which may be connected to the equipment using the backup mechanism of X25 in ISDN D channel access logical ports .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25InDIsdnRemotePeerEntry

fclX25InDIsdnRemotePeerEntry 2.1.866.20.1.20.21.4.1
An entry of fclX25InDIsdnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25InDIsdnRemotePeerEntry  

fclX25InDIsdnRemLogPortId 2.1.866.20.1.20.21.4.1.1
The value of this object identifies one and only one X25 in ISDN D channel access logical port. One X25 in ISDN D channel logical port may use backup mechanism with one or several ISDN remote systems (these ISDN systems can be on different equipments). The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25InDIsdnRemIsdnInterfaceId 2.1.866.20.1.20.21.4.1.2
The value of this object identifies one and only one ISDN remote system. This ISDN remote system must exist in fclIsdnRemotePeerTable. There may be several ISDN remote system for only one X25 in ISDN D channel logical port (these ISDN systems can be on different equipments). The possible values are : '0..249'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclX25InDIsdnRemStatus 2.1.866.20.1.20.21.4.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25InDIsdnRemConnectionType 2.1.866.20.1.20.21.4.1.4
The value of this object indicates which is the system connected by the backup mechanism to this X25 in ISDN-D logical port. The possible values are : subscriber : this X25 ISDN-D logical port logical port is facing to a X25 subscriber, fclX25InDIsdnRemSubscriberNumber is used, fclX25InDIsdnRemPdnLinkAddress is not used, publicNetwork : this logical port is facing to a X25 Public Data Network, fclX25InDIsdnRemSubscriberNumber is not used, fclX25InDIsdnRemPdnLinkAddress is used. The default value is 'subscriber'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER subscriber(1), publicNetwork(2)  

fclX25InDIsdnRemSubscriberNumber 2.1.866.20.1.20.21.4.1.5
The value of this object is the SB number added to the DNICZO of the equipment to make the calling address in a call sent from this X25 in ISDN-D logical port by the backup mechanism (if fclX25InDIsdnRemConnectionType is set to 'subscriber'). The value must contain 2 digits (digits 0..9). The default value is 'FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclX25InDIsdnRemPdnLinkAddress 2.1.866.20.1.20.21.4.1.6
The value of this object is the X121 address of the equipment on the connected network (if fclX25InDIsdnRemConnectionType is set to 'publicNetwork'). The value may contain up to 15 digits (digits 0..9). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclX25InDIsdnRemX25AccConfigId 2.1.866.20.1.20.21.4.1.7
The value of this object identifies the X25 access configuration used by this X25 in ISDN-D logical port. backup link. This X25 access configuration must be present in fclX25ConfigAccessTable. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25InDIsdnRemPriority 2.1.866.20.1.20.21.4.1.8
The value of this object indicates, when there is several ISDN remote system for only one X25 in ISDN D channel logical port, in which order the equipment will try to call these several ISDN remote system to establish an ISDN B Channel. When a try to one ISDN remote system fails the equipment continues, in the increasing order of this parameter, with the following in the list until the end of the list. The possible values are : '0..15'. The default value is '0' (meaning 'first of the list').
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

fclX25InDIsdnRemCallRetryCount 2.1.866.20.1.20.21.4.1.9
The value of this object indicates how many times the equipment will try to call this particular ISDN remote system to establish an ISDN B Channel. The possible values are : '1..15'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclX25InBIsdn 2.1.866.20.1.20.22
OBJECT IDENTIFIER    

fclX25InBIsdnTable 2.1.866.20.1.20.22.1
This table defines the general parameters of X25 SLP (Single Link Protocol) in ISDN B channel logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25InBIsdnEntry

fclX25InBIsdnEntry 2.1.866.20.1.20.22.1.1
An entry of fclX25InBIsdnTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25InBIsdnEntry  

fclX25InBLogPortId 2.1.866.20.1.20.22.1.1.1
The value of this object identifies one and only one X25 in ISDN B Channel logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25InBIsdnInterfaceId 2.1.866.20.1.20.22.1.1.2
The value of this object identifies the ISDN Basic Rate Interface used by this X25 in ISDN-B logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25InBRemotePeerTable 2.1.866.20.1.20.22.2
This table defines the ISDN remote systems which may be connected to the equipment using an X25 in ISDN B channel logical ports .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25InBRemotePeerEntry

fclX25InBRemotePeerEntry 2.1.866.20.1.20.22.2.1
An entry of fclX25InBRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25InBRemotePeerEntry  

fclX25InBRemX121Addr 2.1.866.20.1.20.22.2.1.1
The value of this object is the X121 address of one or several ISDN remote systems. The value may contain up to 15 digits (digits 0..9, A,B,D). The digits 'A', 'B', 'D' (respectively characters ':', '*', '?' on the equipment configurator) have special meanings : 'A' is a separator used to defines which digits of this X121 address are added to the value of fcfIsdnRemIsdnNumber corresponding to fclX25InBRemPeerId to make the complete ISDN address. When used there must be exactly two separators to mark the beginning and the end of the digits selection. 'B' matches any address. When used it must be the only digit specified (with final completion as explained below). 'D' matches any single digit. The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclX25InBRemPeerId 2.1.866.20.1.20.22.2.1.2
The value of this object identifies one and only one ISDN remote system. This ISDN remote system must exist in fclIsdnRemotePeerTable. There may be several ISDN remote system for only one X121 address. The possible values are : '0..249' in releases before 4.2, '0..999' after. If it is unused, the value of this parameter is '255' or '65535'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

fclX25InBRemStatus 2.1.866.20.1.20.22.2.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25InBRemConnectionType 2.1.866.20.1.20.22.2.1.4
The value of this object indicates which is the ISDN remote system connected to one of the X25 in ISDN-B logical port. The possible values are : subscriber : this X25 ISDN-B logical port logical port is facing to a X25 subscriber, fclX25InBRemSubscriberNumber is used, fclX25InBRemPdnLinkAddress is not used, publicNetwork : this logical port is facing to a X25 Public Data Network, fclX25InBRemSubscriberNumber is not used, fclX25InBRemPdnLinkAddress is used. interNode : this logical port is used as inter-node ling (i.e. inside an X25 network), fclX25InBRemSubscriberNumber is not used, fclX25InBRemPdnLinkAddress is not used. The default value is 'subscriber'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER subscriber(1), publicNetwork(2), interNode(3)  

fclX25InBRemSubscriberNumber 2.1.866.20.1.20.22.2.1.5
The value of this object is the SB number added to the DNICZO of the equipment to make the calling address in a call sent to this ISDN remote system (if fclX25InBRemConnectionType is set to 'subscriber'). The value must contain 2 digits (digits 0..9). The default value is 'FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclX25InBRemPdnLinkAddress 2.1.866.20.1.20.22.2.1.6
The value of this object is the X121 address of the equipment on the connected network (if fclX25InBRemConnectionType is set to 'publicNetwork'). The value may contain up to 15 digits (digits 0..9). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclX25InBRemX25ConfigId 2.1.866.20.1.20.22.2.1.7
The value of this object identifies the X25 configuration used to establish the X25 VC towards the ISDN remote system. This X25 configuration must be present in fclX25ConfigAccessTable (case X25 access configuration if fclX25InBRemConnectionType is set to 'subscriber' or 'publicNetwork') or in fclX25ConfigInterNodeTable (case X25 inter-node configuration if fclX25InBRemConnectionType is set to 'interNode'). The possible values are : '0..199'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25InBRemPriority 2.1.866.20.1.20.22.2.1.8
The value of this object indicates, when there is several ISDN remote system for only one X121 address, in which order the equipment will try to call these several ISDN remote system to establish an ISDN B Channel. When a try to one ISDN remote system fails the equipment continues, in the increasing order of this parameter, with the following in the list until the end of the list. The possible values are : '0..15'. The default value is '0' (meaning 'first of the list').
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

fclX25InBRemCallRetryCount 2.1.866.20.1.20.22.2.1.9
The value of this object indicates how many times the equipment will try to call this particular ISDN remote system to establish an ISDN B Channel. The possible values are : '1..15'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclX25InBRemLinkCheckPeriod 2.1.866.20.1.20.22.2.1.10
The value of this object is the scanning time (in milliseconds) to detect the B-Channel state. The authorized values are '2000..50800' by steps of 200 msec. The default value is '200'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 200..50800  

fclX25InBRemCheckPeriodCount 2.1.866.20.1.20.22.2.1.11
The value of this object is the number of periods of 'fclX25InBRemLinkCheckPeriod' milliseconds before declaring the state of the B-Channel. The authorized values are '1..250'. The default value is '3'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..250  

fclX25InPstn 2.1.866.20.1.20.23
OBJECT IDENTIFIER    

fclX25InPstnTable 2.1.866.20.1.20.23.1
This table defines the general parameters of X25 SLP (Single Link Protocol) in PSTN (Public Switched Telephone Network) link inter-node logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25InPstnEntry

fclX25InPstnEntry 2.1.866.20.1.20.23.1.1
An entry of fclX25InPstnTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25InPstnEntry  

fclX25PstnLogPortId 2.1.866.20.1.20.23.1.1.1
The value of this object identifies one and only one X25 in PSTN link logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25PstnInterfaceId 2.1.866.20.1.20.23.1.1.2
The value of this object identifies the line interface used by this X25 in PSTN logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25PstnX25InterNodeConfigId 2.1.866.20.1.20.23.1.1.3
The value of this object identifies the X25 inter-node configuration used to establish the X25 VC towards the PSTN remote system. This X25 inter-node configuration must be present in fclX25ConfigInterNodeTable. The possible values are : '0..199'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25PstnRemotePeerTable 2.1.866.20.1.20.23.2
This table defines the PSTN remote systems which may be called by the equipment using a X25 in PSTN link logical ports .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25PstnRemotePeerEntry

fclX25PstnRemotePeerEntry 2.1.866.20.1.20.23.2.1
An entry of fclX25PstnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25PstnRemotePeerEntry  

fclX25PstnRemX121Addr 2.1.866.20.1.20.23.2.1.1
The value of this object is the X121 address of one PSTN remote system. The value may contain up to 15 digits (digits 0..9, B, D). The digits 'B', 'D' (respectively characters '*', '?' on the equipment configurator) have special meanings : 'B' matches any address. When used it must be the only digit specified (with final completion as explained below). 'D' matches any single digit. The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclX25PstnRemStatus 2.1.866.20.1.20.23.2.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25PstnRemPstnNumber 2.1.866.20.1.20.23.2.1.3
The value of this object is the PSTN address of this PSTN remote system. The value may contain up to 28 digits (digits 0..E). The digits 'A', 'B', 'C', 'D', 'E' (respectively characters 'W', ',', 'P', 'T', '!' on the equipment configurator) have special meanings : 'A' means 'attente de tonalite', 'B' means 'pause of 2 seconds', 'C' means 'numerotation decimale', 'D' means 'numerotation multifrequence', 'E' means 'raccrocher 0.5 second'. The value must be completed with 'F' digits for a total of 28 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(14)  

fclX25SlpInterNode 2.1.866.20.1.20.24
OBJECT IDENTIFIER    

fclX25SlpInterNodeTable 2.1.866.20.1.20.24.1
This table defines the general parameters of X25 SLP (Single Link Protocol) inter-node logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25SlpInterNodeEntry

fclX25SlpInterNodeEntry 2.1.866.20.1.20.24.1.1
An entry of fclX25SlpInterNodeTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25SlpInterNodeEntry  

fclX25SlpLogPortId 2.1.866.20.1.20.24.1.1.1
The value of this object identifies one and only one X25 SLP (Single Link Protocol) inter-node logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25SlpInterfaceId 2.1.866.20.1.20.24.1.1.2
The value of this object identifies the line interface used by this X25 inter-node logical port. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..181  

fclX25SlpIsdnBackupEnabling 2.1.866.20.1.20.24.1.1.3
The value of this object defines how this X25 inter-node logical port may be backuped by an ISDN-B channel. The possible values are : off : backup is never enabled, onWhileActivity : when the logical port is DOWN, backup is enabled on reception of a new call and remains active while at least one X25 VC is using this way. When no VC is active, the backup is disabled and the next VC will be established on the logical port (if it is UP obviously). onWhileLpDown : when the logical port is DOWN, backup is enabled on reception of a new call and remains active while the logical port is DOWN. The backup is disabled (meaning clearing of all VCs using this way) when the logical port comes back UP and the next VC will be established on the logical port. onWhileExcessTraffic : when the traffic overtakes the fclX25SlpSwSwitchThreshold value the logical port state is marked DOWN (meaning clearing of all VCs), backup is enabled on reception of a new call and remains active while the traffic is overtaking the fclX25SlpSwSwitchBackThreshold value. When the traffic does not overtake any more the fclX25SlpSwSwitchBackThreshold value, the logical port is marked UP and the backup is disabled (meaning clearing of all VCs using this way) so the next VC will be established on the logical port. This Switch Over mechanism permits to transmit temporay excess traffic which could not be transmitted on the logical port because of an insufficient bandwith on a line interface with a speed (fcfLineSpeed) inferior to 64 kbit/s. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onWhileActivity(2), onWhileLpDown(3), onWhileExcessTraffic(7)  

fclX25SlpPstnBackupEnabling 2.1.866.20.1.20.24.1.1.4
The value of this object defines how this X25 inter-node logical port may be backuped by a PSTN (Public Switched Telephone Network) link. The possible values are : off : backup is never enabled, onWhileActivity : when the logical port is DOWN, backup is enabled on reception of a new call and remains active while at least one X25 VC is using this way. When no VC is active, the backup is disabled and the next VC will be established on the logical port (if it is UP obviously). onWhileLpDown : when the logical port is DOWN, backup is enabled on reception of a new call and remains active while the logical port is DOWN. The backup is disabled (meaning clearing of all VCs using this way) when the logical port comes back UP and the next VC will be established on the logical port. onWhileExcessTraffic : when the traffic overtakes the fclX25SlpSwSwitchThreshold value the logical port state is marked DOWN (meaning clearing of all VCs), backup is enabled on reception of a new call and remains active while the traffic is overtaking the fclX25SlpSwSwitchBackThreshold value. When the traffic does not overtake any more the fclX25SlpSwSwitchBackThreshold value, the logical port is marked UP and the backup is disabled (meaning clearing of all VCs using this way) so the next VC will be established on the logical port. This Switch Over mechanism permits to transmit temporay excess traffic which could not be transmitted on the logical port because of an insufficient bandwith on a line interface with a speed (fcfLineSpeed) inferior to the speed of a PSTN link (depending on modem capability). The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onWhileActivity(2), onWhileLpDown(3), onWhileExcessTraffic(7)  

fclX25SlpX25InterNodeConfigId 2.1.866.20.1.20.24.1.1.5
The value of this object identifies the X25 inter-node configuration used by this X25 inter-node logical port. This X25 inter-node configuration must be present in fclX25ConfigInterNodeTable. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25SlpDARApplicable 2.1.866.20.1.20.24.1.1.6
Ligne utilisable par le RAD
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclX25SlpBackupTimer 2.1.866.20.1.20.24.1.1.7
Tempo de retour sur LS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2540  

fclX25SlpSwitchOverTable 2.1.866.20.1.20.24.2
This table defines the switch over parameters of X25 inter-node logical ports using the switch over mechanism.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25SlpSwitchOverEntry

fclX25SlpSwitchOverEntry 2.1.866.20.1.20.24.2.1
An entry of fclX25SlpSwitchOverTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25SlpSwitchOverEntry  

fclX25SlpSwLogPortId 2.1.866.20.1.20.24.2.1.1
The value of this object identifies one and only one X25 inter-node logical port using the switch over mechanism (fclX25SlpIsdnBackupEnabling or fclX25SlpPstnBackupEnabling set to 'onWhileExcessTraffic'). The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25SlpSwMeasureCount 2.1.866.20.1.20.24.2.1.2
The value of this object is the number of traffic measures before switching. The measure duration is defined by fcwLoadAndTrafficSummingPeriod. The authorized values are '0..249'. The default value is '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..249  

fclX25SlpSwSwitchThreshold 2.1.866.20.1.20.24.2.1.3
The value of this object indicates the traffic threshold (in percents of bandwith of the main link of logical port) over which the switch over mechanism is enabled. The authorized values are '0..100'. The default value is '80'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclX25SlpSwSwitchBackThreshold 2.1.866.20.1.20.24.2.1.4
The value of this object indicates the traffic threshold (in percents of bandwith of the main link of logical port) under which the switch over mechanism is disabled. The authorized values are '0..100'. The default value is '60'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclX25SlpIsdnBackupTable 2.1.866.20.1.20.24.3
This table defines which ISDN Basic Rate Interface may be used by each X25 inter-node logical port when enabling backup on ISDN B-Channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25SlpIsdnBackupEntry

fclX25SlpIsdnBackupEntry 2.1.866.20.1.20.24.3.1
An entry of fclX25SlpIsdnBackupTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25SlpIsdnBackupEntry  

fclX25SlpIsdnBackLogPortId 2.1.866.20.1.20.24.3.1.1
The value of this object identifies one and only one X25 SLP (Single Link Protocol) inter-node logical port. One X25 inter-node logical port may use backup with one or several ISDN Basic Rate Interfaces. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25SlpIsdnBackIsdnInterfaceId 2.1.866.20.1.20.24.3.1.2
The value of this object identifies one ISDN Basic Rate Interface used by the X25 inter-node logical port defined by fclX25SlpIsdnBackLogPortId. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclX25SlpIsdnBackStatus 2.1.866.20.1.20.24.3.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25SlpIsdnRemotePeerTable 2.1.866.20.1.20.24.4
This table defines the ISDN remote systems which may be connected to the equipment using the backup mechanism of X25 inter-node logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25SlpIsdnRemotePeerEntry

fclX25SlpIsdnRemotePeerEntry 2.1.866.20.1.20.24.4.1
An entry of fclX25SlpIsdnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25SlpIsdnRemotePeerEntry  

fclX25SlpIsdnRemLogPortId 2.1.866.20.1.20.24.4.1.1
The value of this object identifies one and only one X25 SLP (Single Link Protocol) inter-node logical port. One X25 inter-node logical port may use backup mechanism with one or several ISDN remote systems (these ISDN systems can be on different equipments). The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25SlpIsdnRemIsdnInterfaceId 2.1.866.20.1.20.24.4.1.2
The value of this object identifies one and only one ISDN remote system. This ISDN remote system must exist in fclIsdnRemotePeerTable. There may be several ISDN remote system for only one X25 inter-node logical port (these ISDN systems can be on different equipments). The possible values are : '0..249'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclX25SlpIsdnRemStatus 2.1.866.20.1.20.24.4.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25SlpIsdnRemX25InterNodeConfigId 2.1.866.20.1.20.24.4.1.4
The value of this object identifies the X25 inter-node configuration used by this X25 inter-node logical port backup link. This X25 inter-node configuration must be present in fclX25ConfigInterNodeTable. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25SlpIsdnRemPriority 2.1.866.20.1.20.24.4.1.5
The value of this object indicates, when there is several ISDN remote system for only one X25 inter-node logical port, in which order the equipment will try to call these several ISDN remote system to establish an ISDN B Channel. When a try to one ISDN remote system fails the equipment continues, in the increasing order of this parameter, with the following in the list until the end of the list. The possible values are : '0..15'. The default value is '0' (meaning 'first of the list').
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

fclX25SlpIsdnRemCallRetryCount 2.1.866.20.1.20.24.4.1.6
The value of this object indicates how many times the equipment will try to call this particular ISDN remote system to establish an ISDN B Channel. The possible values are : '1..15'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclX25SlpPstnBackupTable 2.1.866.20.1.20.24.5
This table defines which line interface may be used by each X25 inter-node logical ports when enabling backup mechanism on PSTN links.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25SlpPstnBackupEntry

fclX25SlpPstnBackupEntry 2.1.866.20.1.20.24.5.1
An entry of fclX25SlpPstnBackupTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25SlpPstnBackupEntry  

fclX25SlpPstnBackLogPortId 2.1.866.20.1.20.24.5.1.1
The value of this object identifies one and only one X25 SLP (Single Link Protocol) inter-node logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25SlpPstnBackStatus 2.1.866.20.1.20.24.5.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25SlpPstnBackInterfaceId 2.1.866.20.1.20.24.5.1.3
The value of this object identifies the line interface used by the X25 inter-node logical port defined by fclX25SlpPstnBackLogPortId. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25SlpPstnBackPstnNumber 2.1.866.20.1.20.24.5.1.4
The value of this object is the PSTN address of this PSTN remote system. The value may contain up to 28 digits (digits 0..E). The digits 'A', 'B', 'C', 'D', 'E' (respectively characters 'W', ',', 'P', 'T', '!' on the equipment configurator) have special meanings : 'A' means 'attente de tonalite', 'B' means 'pause of 2 seconds', 'C' means 'numerotation decimale', 'D' means 'numerotation multifrequence', 'E' means 'raccrocher 0.5 second'. The value must be completed with 'F' digits for a total of 28 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(14)  

fclX25SlpPstnBackX25InterNodeConfigId 2.1.866.20.1.20.24.5.1.5
The value of this object identifies the X25 inter-node configuration used by this X25 inter-node logical port backup link. This X25 inter-node configuration must be present in fclX25ConfigInterNodeTable. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25Mlp 2.1.866.20.1.20.25
OBJECT IDENTIFIER    

fclX25MlpTable 2.1.866.20.1.20.25.1
This table defines the general parameters of X25 MLP (Multi-Link Protocol) inter-node logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25MlpEntry

fclX25MlpEntry 2.1.866.20.1.20.25.1.1
An entry of fclX25MlpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25MlpEntry  

fclX25MlpLogPortId 2.1.866.20.1.20.25.1.1.1
The value of this object identifies one and only one X25 MLP (Multi-Link Protocol) inter-node logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25MlpLink1InterfaceId 2.1.866.20.1.20.25.1.1.2
The value of this object identifies the first line interface used by this X25 MLP logical port. This line interface is mandatory. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25MlpLink2InterfaceId 2.1.866.20.1.20.25.1.1.3
The value of this object identifies the second line interface used by this X25 MLP logical port. This line interface is optional. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25MlpLink3InterfaceId 2.1.866.20.1.20.25.1.1.4
The value of this object identifies the third line interface used by this X25 MLP logical port. This line interface is optional. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25MlpLink4InterfaceId 2.1.866.20.1.20.25.1.1.5
The value of this object identifies the fourth line interface used by this X25 MLP logical port. This line interface is optional. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25MlpIsdnOverflow 2.1.866.20.1.20.25.1.1.6
The value of this object defines how this X25 MLP logical port may use additional ISDN-B channel to transmit temporary excess traffic (overflow mechanism). When opening or closing additional B-Channels the existing VCs are not cleared, so this overflow mechanism does not alter the communication between the two extremities. The possible values are : off : overflow is never enabled, onSlave : overflow is enabled by the connected equipment, onMasterWhileActivity : when the traffic overtakes the fclX25MlpOvOverflowThreshold value for all the links in use (line interfaces and eventual ISDN B-Channels), a new ISDN B-Channel is open by the equipment and remains active while at least one X25 VC is using this way. When no VC is active, this ISDN B-Channel is closed. onMasterWhileExcessTraffic : when the traffic overtakes the fclX25MlpOvOverflowThreshold value for all the links in use (line interfaces and eventual ISDN B-Channels), a new ISDN B-Channel is open by the equipment and remains active while the traffic is overtaking the fclX25SlpOvOverflowBackThreshold value. When the traffic does not overtake any more the fclX25SlpOvOverflowBackThreshold value, this ISDN B-Channel is closed. When one line interface is DOWN its bandwith is considered as being 0. So the overflow mechanism may be used as a backup mechanism which permits to not clear existing VCs. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onSlave(2), onMasterWhileActivity(10), onMasterWhileExcessTraffic(11)  

fclX25MlpPstnOverflow 2.1.866.20.1.20.25.1.1.7
The value of this object defines how this X25 MLP logical port may use additional PSTN links to transmit temporary excess traffic (overflow mechanism). When opening or closing additional PSTN links the existing VCs are not cleared, so this overflow mechanism does not alter the communication between the two extremities. The possible values are : off : overflow is never enabled, onSlave : overflow is enabled by the connected equipment, onMasterWhileActivity : when the traffic overtakes the fclX25MlpOvOverflowThreshold value for all the links in use (line interfaces and eventual PSTN links), a new PSTN link is open by the equipment and remains active while at least one X25 VC is using this way. When no VC is active, this PSTN link is closed. onMasterWhileExcessTraffic : when the traffic overtakes the fclX25MlpOvOverflowThreshold value for all the links in use (line interfaces and eventual PSTN links), a new PSTN link is open by the equipment and remains active while the traffic is overtaking the fclX25SlpOvOverflowBackThreshold value. When the traffic does not overtake any more the fclX25SlpOvOverflowBackThreshold value, this PSTN link is closed. When one line interface is DOWN its bandwith is considered as being 0. So the overflow mechanism may be used as a backup mechanism which permits to not clear existing VCs. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onSlave(2), onMasterWhileActivity(10), onMasterWhileExcessTraffic(11)  

fclX25MlpX25InterNodeConfigId 2.1.866.20.1.20.25.1.1.8
The value of this object identifies the X25 inter-node configuration used by this X25 MLP logical port. This X25 inter-node configuration must be present in fclX25ConfigInterNodeTable. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25MlpDARApplicable 2.1.866.20.1.20.25.1.1.9
Ligne utilisable par le RAD
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fclX25MlpParameterTable 2.1.866.20.1.20.25.2
This table defines the MLP parameters of X25 MLP (Multi-Link Protocol) inter-node logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25MlpParameterEntry

fclX25MlpParameterEntry 2.1.866.20.1.20.25.2.1
An entry of fclX25MlpParameterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25MlpParameterEntry  

fclX25MlpParamLogPortId 2.1.866.20.1.20.25.2.1.1
The value of this object identifies one and only one X25 MLP (Multi-Link Protocol) inter-node logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25MlpMwMultilinkWindowSize 2.1.866.20.1.20.25.2.1.2
The value of this object is the maximum number (MW) of sequentially numbered multilink frames that the DCE or DTE may transfer which the lowest numbered multilink frame which has not yet been acknowledged beyond. This parameter shall have the same value for both switching points. The authorized values are '1..32'. The default value is '32'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..32  

fclX25MlpRxMlpMxWinGuardRegion 2.1.866.20.1.20.25.2.1.3
The value of this object defines a guard region (MX) of multilink sequence numbers of fixed size. The range of MX shall be large enough for that the receiving MLP recognizes the highest numbered frame that it may receive after the multilink frame loss. The window MX must be smaller than or equal to the window MW. The authorized values are '1..32'. The default value is '32'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..32  

fclX25MlpMt1LostFrameTimer 2.1.866.20.1.20.25.2.1.4
The value of this object defines the timer (MT1), in seconds, which a transmitted frames is declared lost beyond. The authorized values are '1..255'. The default value is '22'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclX25MlpMt3ResetConfirmationTimer 2.1.866.20.1.20.25.2.1.5
The value of this object defines the maximum time (MT3), in seconds, between a reset request and a reset confirmation, which the multilink resetting procedure restarts beyond. The authorized values are '1..255'. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclX25MlpMt4DownLinkDetectionTimer 2.1.866.20.1.20.25.2.1.6
The value of this object defines the timer (MT4), in seconds, which the line is declared down beyond. The line is out if all the lines of the MLP group are down. The authorized values are '0..255'. The default value is '40'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  


fclX25MlpRestartTxAfterResetRx 2.1.866.20.1.20.25.2.1.8
The value of this object indicates if there is recovery after MLP reset. The authorized values are 'off' or 'on'. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25MlpTns3Level3CheckTimer 2.1.866.20.1.20.25.2.1.9
The value of this object defines the timer, in seconds, between a sending of frames and the reception of its acknowledges, which the multilink resetting procedure restarts beyond. The authorized values are '0..255' by step of 10 seconds. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fclX25MlpOverflowTable 2.1.866.20.1.20.25.3
This table defines the overflow parameters of X25 MLP logical ports enabling the overflow mechanism.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25MlpOverflowEntry

fclX25MlpOverflowEntry 2.1.866.20.1.20.25.3.1
An entry of fclX25MlpOverflowTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25MlpOverflowEntry  

fclX25MlpOvLogPortId 2.1.866.20.1.20.25.3.1.1
The value of this object identifies one and only one X25 MLP logical port enabling the overflow mechanism (fclX25MlpIsdnOverflow or fclX25MlpPstnOverflow set to 'onMasterWhileActivity', 'onMasterWhileExcessTraffic'). The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25MlpOvMeasureCount 2.1.866.20.1.20.25.3.1.2
The value of this object is the number of traffic measures before opening an additional link. The measure duration is defined by fcwLoadAndTrafficSummingPeriod. The authorized values are '0..249'. The default value is '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..249  

fclX25MlpOvOverflowThreshold 2.1.866.20.1.20.25.3.1.3
The value of this object indicates the traffic threshold (in percents of bandwith of alls the link in use by this logical port) over which a new link is open. The authorized values are '0..100'. The default value is '80'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclX25MlpOvOverflowBackThreshold 2.1.866.20.1.20.25.3.1.4
The value of this object indicates the traffic threshold (in percents of bandwith of alls the link in use by this logical port) under which the last open link is closed. The authorized values are '0..100'. The default value is '60'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclX25MlpIsdnOverflowTable 2.1.866.20.1.20.25.4
This table defines which ISDN Basic Rate Interface may be used by each X25 MLP logical ports when enabling overflow mechanism on ISDN B-Channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25MlpIsdnOverflowEntry

fclX25MlpIsdnOverflowEntry 2.1.866.20.1.20.25.4.1
An entry of fclX25MlpIsdnOverflowTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25MlpIsdnOverflowEntry  

fclX25MlpIsdnOverLogPortId 2.1.866.20.1.20.25.4.1.1
The value of this object identifies one and only one X25 MLP (Multi-Link Protocol) inter-node logical port. One X25 MLP logical port may use overflow mechanism with one or several ISDN Basic Rate Interfaces. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25MlpIsdnOverIsdnInterfaceId 2.1.866.20.1.20.25.4.1.2
The value of this object identifies one ISDN Basic Rate Interface used by the X25 MLP logical port defined by fclX25MlpIsdnOverLogPortId. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclX25MlpIsdnOverStatus 2.1.866.20.1.20.25.4.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25MlpIsdnOverBChannelCount 2.1.866.20.1.20.25.4.1.4
The value of this object is the number of B channels of this ISDN Basic Rate Interface that may be used. The authorized values are '1..30'. The default value is '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..30  

fclX25MlpIsdnRemotePeerTable 2.1.866.20.1.20.25.5
This table defines the ISDN remote systems which may be connected to the equipment using the overflow mechanism of X25 MLP logical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25MlpIsdnRemotePeerEntry

fclX25MlpIsdnRemotePeerEntry 2.1.866.20.1.20.25.5.1
An entry of fclX25MlpIsdnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25MlpIsdnRemotePeerEntry  

fclX25MlpIsdnRemLogPortId 2.1.866.20.1.20.25.5.1.1
The value of this object identifies one and only one X25 MLP (Multi-Link Protocol) inter-node logical port. One X25 MLP logical port may use overflow mechanism with one or several ISDN remote systems (but all these ISDN systems must be on the same equipment to make X25 MLP work correctly). The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25MlpIsdnRemPeerId 2.1.866.20.1.20.25.5.1.2
The value of this object identifies one and only one ISDN remote system. This ISDN remote system must exist in fclIsdnRemotePeerTable. There may be several ISDN remote system for only one X25 MLP logical port (but all these ISDN systems must be on the same equipment to make X25 MLP work correctly). The possible values are : '0..249'. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclX25MlpIsdnRemStatus 2.1.866.20.1.20.25.5.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25MlpIsdnRemPriority 2.1.866.20.1.20.25.5.1.4
The value of this object indicates, when there is several ISDN remote system for only one X25 MLP logical port, in which order the equipment will try to call these several ISDN remote system to establish an ISDN B Channel. When a try to one ISDN remote system fails the equipment continues, in the increasing order of this parameter, with the following in the list until the end of the list. The possible values are : '0..15'. The default value is '0' (meaning 'first of the list').
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

fclX25MlpIsdnRemCallRetryCount 2.1.866.20.1.20.25.5.1.5
The value of this object indicates how many times the equipment will try to call this particular ISDN remote system to establish an ISDN B Channel. The possible values are : '1..15'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclX25MlpPstnOverflowTable 2.1.866.20.1.20.25.6
This table defines which line interface may be used by each X25 MLP logical ports when enabling overflow mechanism on PSTN links.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25MlpPstnOverflowEntry

fclX25MlpPstnOverflowEntry 2.1.866.20.1.20.25.6.1
An entry of fclX25MlpPstnOverflowTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25MlpPstnOverflowEntry  

fclX25MlpPstnOvLogPortId 2.1.866.20.1.20.25.6.1.1
The value of this object identifies one and only one X25 MLP (Multi-Link Protocol) inter-node logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25MlpPstnOvStatus 2.1.866.20.1.20.25.6.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25MlpPstnOvInterfaceId 2.1.866.20.1.20.25.6.1.3
The value of this object identifies the line interface used by the X25 MLP logical port defined by fclX25MlpPstnOverLogPortId. The possible values are : '0..35'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclX25MlpPstnOvPstnNumber 2.1.866.20.1.20.25.6.1.4
The value of this object is the PSTN address of this PSTN remote system. The value may contain up to 28 digits (digits 0..E). The digits 'A', 'B', 'C', 'D', 'E' (respectively characters 'W', ',', 'P', 'T', '!' on the equipment configurator) have special meanings : 'A' means 'attente de tonalite', 'B' means 'pause of 2 seconds', 'C' means 'numerotation decimale', 'D' means 'numerotation multifrequence', 'E' means 'raccrocher 0.5 second'. The value must be completed with 'F' digits for a total of 28 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(14)  

fclPointToPointProtocol 2.1.866.20.1.20.30
OBJECT IDENTIFIER    

fclPppSerialLinkAccess 2.1.866.20.1.20.30.1
OBJECT IDENTIFIER    

fclPppSerialLogPortTable 2.1.866.20.1.20.30.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppSerialLogPortEntry

fclPppSerialLogPortEntry 2.1.866.20.1.20.30.1.1.1
An entry of fclPppSerialLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppSerialLogPortEntry  

fclPppSerLpLogPortId 2.1.866.20.1.20.30.1.1.1.1
LP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclPppSerLpInterfaceId 2.1.866.20.1.20.30.1.1.1.2
IF id (type ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..181  

fclPppSerLpLocalSubscriberNb 2.1.866.20.1.20.30.1.1.1.3
Numero d'abonne
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclPppSerLpConfigId 2.1.866.20.1.20.30.1.1.1.10
Config PPP id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclPppSerLpCos 2.1.866.20.1.20.30.1.1.1.20
COS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1)  

fclPppSerLpCir 2.1.866.20.1.20.30.1.1.1.21
Entrant CIR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 600..2048000  

fclPppSerLpMinCir 2.1.866.20.1.20.30.1.1.1.22
Entrant CIR mini
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclPppSerLpBe 2.1.866.20.1.20.30.1.1.1.23
Entrant BE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclPppSerialAutoCallTable 2.1.866.20.1.20.30.1.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppSerialAutoCallEntry

fclPppSerialAutoCallEntry 2.1.866.20.1.20.30.1.2.1
An entry of fclPppSerialAutoCallTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppSerialAutoCallEntry  

fclPppSerAutoLogPortId 2.1.866.20.1.20.30.1.2.1.1
LP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclPppSerAutoStatus 2.1.866.20.1.20.30.1.2.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclPppSerAutoRemoteAddress 2.1.866.20.1.20.30.1.2.1.3
Adresse du point vise
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclPppSerAutoMinimumRecallTimer 2.1.866.20.1.20.30.1.2.1.7
Tempo de retransmission appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclPppSerAutoInactivityTimer 2.1.866.20.1.20.30.1.2.1.8
Duree de silence (Tb)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2540  

fclPppSerAutoReliableVc 2.1.866.20.1.20.30.1.2.1.10
CV fiabilise
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(3), on(2)  

fclPppSerAutoCompression 2.1.866.20.1.20.30.1.2.1.11
Compression : abonnement et direction
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), networkToSubscriber(2), subscriberToNetwork(3), bothway(4)  

fclPppSerAutoCompressNegotiation 2.1.866.20.1.20.30.1.2.1.12
Compression : negociation et caractere
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onOptionalCompression(2), onMandatoryCompression(3)  

fclPppSerAutoCompressScrambling 2.1.866.20.1.20.30.1.2.1.13
Compression : brouillage
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclPppSerAutoCompressMultiPktTimer 2.1.866.20.1.20.30.1.2.1.14
Compression : tempo attente multi-paquet msec
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

fclPppPstnAccess 2.1.866.20.1.20.30.2
OBJECT IDENTIFIER    

fclPppPstnLogPortTable 2.1.866.20.1.20.30.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppPstnLogPortEntry

fclPppPstnLogPortEntry 2.1.866.20.1.20.30.2.1.1
An entry of fclPppPstnLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppPstnLogPortEntry  

fclPppPstnLpLogPortId 2.1.866.20.1.20.30.2.1.1.1
LP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclPppPstnLpInterfaceId 2.1.866.20.1.20.30.2.1.1.2
IF id (de type ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclPppPstnLpLocalSubscriberNb 2.1.866.20.1.20.30.2.1.1.3
Numero d'abonne
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclPppPstnLpConfigId 2.1.866.20.1.20.30.2.1.1.10
Config PPP id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclPppPstnRemotePeerTable 2.1.866.20.1.20.30.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppPstnRemotePeerEntry

fclPppPstnRemotePeerEntry 2.1.866.20.1.20.30.2.2.1
An entry of fclPppPstnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppPstnRemotePeerEntry  

fclPppPstnRemX121Addr 2.1.866.20.1.20.30.2.2.1.1
Adresse X121
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclPppPstnRemStatus 2.1.866.20.1.20.30.2.2.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclPppPstnRemPstnNumber 2.1.866.20.1.20.30.2.2.1.3
Numero RTC
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(14)  

fclPppBIsdnAccess 2.1.866.20.1.20.30.3
OBJECT IDENTIFIER    

fclPppBIsdnLogPortTable 2.1.866.20.1.20.30.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppBIsdnLogPortEntry

fclPppBIsdnLogPortEntry 2.1.866.20.1.20.30.3.1.1
An entry of fclPppBIsdnLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppBIsdnLogPortEntry  

fclPppBIsdnLpLogPortId 2.1.866.20.1.20.30.3.1.1.1
LP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclPppBIsdnLpIsdnInterfaceId 2.1.866.20.1.20.30.3.1.1.2
IF id (de type RNIS S0)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclPppBIsdnLocalBriTable 2.1.866.20.1.20.30.3.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppBIsdnLocalBriEntry

fclPppBIsdnLocalBriEntry 2.1.866.20.1.20.30.3.2.1
An entry of fclPppBIsdnLocalBriTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppBIsdnLocalBriEntry  

fclPppBIsdnBriId 2.1.866.20.1.20.30.3.2.1.1
IF id (de type RNIS S0)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclPppBIsdnBriStatus 2.1.866.20.1.20.30.3.2.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclPppBIsdnBriLocalSubsNb1 2.1.866.20.1.20.30.3.2.1.3
Numero d'abonne 1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclPppBIsdnBriLocalSubsNb2 2.1.866.20.1.20.30.3.2.1.4
Numero d'abonne 2
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclPppBIsdnRemotePeerTable 2.1.866.20.1.20.30.3.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppBIsdnRemotePeerEntry

fclPppBIsdnRemotePeerEntry 2.1.866.20.1.20.30.3.3.1
An entry of fclPppBIsdnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppBIsdnRemotePeerEntry  

fclPppBIsdnRemX121Addr 2.1.866.20.1.20.30.3.3.1.1
Adresse X121
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclPppBIsdnRemPeerId 2.1.866.20.1.20.30.3.3.1.2
Interface RNIS distante id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

fclPppBIsdnRemStatus 2.1.866.20.1.20.30.3.3.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclPppBIsdnRemConfigId 2.1.866.20.1.20.30.3.3.1.4
Config PPP id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclPppBIsdnRemPriority 2.1.866.20.1.20.30.3.3.1.5
Priorite
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

fclPppBIsdnRemCallRetryCount 2.1.866.20.1.20.30.3.3.1.6
Nb de tentatives appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclPppBIsdnRemLinkCheckPeriod 2.1.866.20.1.20.30.3.3.1.7
Periode de surveillance jonction (msec)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 200..50800  

fclPppBIsdnRemCheckPeriodCount 2.1.866.20.1.20.30.3.3.1.8
Confirmation au bout de n periodes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..250  

fclPppBIsdnLocalPriTable 2.1.866.20.1.20.30.3.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppBIsdnLocalPriEntry

fclPppBIsdnLocalPriEntry 2.1.866.20.1.20.30.3.4.1
An entry of fclPppBIsdnLocalPriTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppBIsdnLocalPriEntry  

fclPppBIsdnPriId 2.1.866.20.1.20.30.3.4.1.1
IF id (de type RNIS S2)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fclPppBIsdnPriStatus 2.1.866.20.1.20.30.3.4.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclPppBIsdnPriLocalSubs 2.1.866.20.1.20.30.3.4.1.3
Numero d'abonne
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..24)  

fclPppConfig 2.1.866.20.1.20.30.10
OBJECT IDENTIFIER    

fclPppConfigurationsTable 2.1.866.20.1.20.30.10.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppConfigurationsEntry

fclPppConfigurationsEntry 2.1.866.20.1.20.30.10.10.1
An entry of fclPppConfigurationsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppConfigurationsEntry  

fclPppCfgConfigId 2.1.866.20.1.20.30.10.10.1.1
Config PPP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclPppCfgStatus 2.1.866.20.1.20.30.10.10.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclPppCfgDescription 2.1.866.20.1.20.30.10.10.1.3
Description
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

fclPppCfgLcpMagicNumber 2.1.866.20.1.20.30.10.10.1.10
LCP Utilisation du Magic Number
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclPppCfgLcpLocalMru 2.1.866.20.1.20.30.10.10.1.11
LCP Local Maximum Receive Unit
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mru100(1), mru200(2), mru300(3), mru400(4), mru500(5), mru600(6), mru700(7), mru800(8), mru900(9), mru1000(10), mru1100(11), mru1200(12), mru1300(13), mru1400(14), mru1500(15), mru1600(16)  

fclPppCfgLcpLocalMtu 2.1.866.20.1.20.30.10.10.1.12
LCP Local Maximum Transmit Unit
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mtu100(1), mtu200(2), mtu300(3), mtu400(4), mtu500(5), mtu600(6), mtu700(7), mtu800(8), mtu900(9), mtu1000(10), mtu1100(11), mtu1200(12), mtu1300(13), mtu1400(14), mtu1500(15), mtu1600(16)  

fclPppCfgNcpBridge 2.1.866.20.1.20.30.10.10.1.20
Bridge NCP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclPppCfgNcpIp 2.1.866.20.1.20.30.10.10.1.25
IP NCP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclPppCfgNcpIpx 2.1.866.20.1.20.30.10.10.1.30
IPX NCP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclPppCfgNcpClnp 2.1.866.20.1.20.30.10.10.1.35
CLNP NCP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclPppCfgAuthentication 2.1.866.20.1.20.30.10.10.1.40
Option authentification
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), pap(2), chap(3), papAndChap(4)  

fclPppCfgAuthenticationMode 2.1.866.20.1.20.30.10.10.1.41
Mode authentification
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER master(1), slave(2), masterAndSlave(3)  

fclPppCfgIpAddrAssignment 2.1.866.20.1.20.30.10.10.1.42
Option adresse IP dynamique
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), byLocalSubscriber(2), byRemotePeer(3)  

fclPppConfigTimersTable 2.1.866.20.1.20.30.10.11
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppConfigTimersEntry

fclPppConfigTimersEntry 2.1.866.20.1.20.30.10.11.1
An entry of fclPppConfigTimersTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppConfigTimersEntry  

fclPppCftConfigId 2.1.866.20.1.20.30.10.11.1.1
Config PPP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclPppCftLcpEchoRequestPeriod 2.1.866.20.1.20.30.10.11.1.10
Periode d'emission des echo requests LCP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fclPppCftConnectionTimer 2.1.866.20.1.20.30.10.11.1.20
Temporisateur de surveillance
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fclPppCftRestartTimer 2.1.866.20.1.20.30.10.11.1.21
Tempo de reemission des messages
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fclPppCftConfigureMaxCount 2.1.866.20.1.20.30.10.11.1.22
Nombre max de retransmission des configure request
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fclPppCftTerminateMaxCount 2.1.866.20.1.20.30.10.11.1.23
Nombre max de retransmission des terminate request
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fclPppCftFailureMaxCount 2.1.866.20.1.20.30.10.11.1.24
Nombre max de retransmission des configure nak
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fclPppConfigAuthentication 2.1.866.20.1.20.30.10.20
OBJECT IDENTIFIER    

fclPppCfaLocalIdentifier 2.1.866.20.1.20.30.10.20.1
Identite de l'equipement local
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..16)  

fclPppCfaLocalPassword 2.1.866.20.1.20.30.10.20.2
Mot de passe de l'equipement local
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..16)  

fclPppCfaRemotePeerTable 2.1.866.20.1.20.30.10.20.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclPppCfaRemotePeerEntry

fclPppCfaRemotePeerEntry 2.1.866.20.1.20.30.10.20.10.1
An entry of fclPppCfaRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclPppCfaRemotePeerEntry  

fclPppCfaRemPeerId 2.1.866.20.1.20.30.10.20.10.1.1
Distant Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclPppCfaRemStatus 2.1.866.20.1.20.30.10.20.10.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclPppCfaRemIdentifier 2.1.866.20.1.20.30.10.20.10.1.3
Identite de l'equipement distant
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..16)  

fclPppCfaRemPassword 2.1.866.20.1.20.30.10.20.10.1.4
Mot de passe de l'equipement distant
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..16)  

fclFrameRelay 2.1.866.20.1.20.40
OBJECT IDENTIFIER    

fclFrCommunicationEquipment 2.1.866.20.1.20.40.1
OBJECT IDENTIFIER    

fclFrCeLogPortTable 2.1.866.20.1.20.40.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrCeLogPortEntry

fclFrCeLogPortEntry 2.1.866.20.1.20.40.1.1.1
An entry of fclFrCeLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrCeLogPortEntry  

fclFrCeLpLogPortId 2.1.866.20.1.20.40.1.1.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFrCeLpInterfaceId 2.1.866.20.1.20.40.1.1.1.2
IF Id (type ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..181  

fclFrCeLpLocalAddress 2.1.866.20.1.20.40.1.1.1.5
Adresse de localisation sur le plan d'adressage du routage (Numero d'abonne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclFrCeLpConfigId 2.1.866.20.1.20.40.1.1.1.10
Configuration FR-CE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCeLpLmi 2.1.866.20.1.20.40.1.1.1.11
LMI
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), lmiNui(3), lmiNni(4)  

fclFrCeParGenTable 2.1.866.20.1.20.40.1.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrCeParGenEntry

fclFrCeParGenEntry 2.1.866.20.1.20.40.1.2.1
An entry of fclFrCeParGenTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrCeParGenEntry  

fclFrCeParGenLogPortId 2.1.866.20.1.20.40.1.2.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFrCeParGenDlcSetupAlarmThreshold 2.1.866.20.1.20.40.1.2.1.30
A% Seuil alarmique d'acceptation des connexions (pourcentage du debit de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclFrCeParGenDlcSetupDiscardThreshold 2.1.866.20.1.20.40.1.2.1.31
R% Seuil de refus d'etablissement des DLC VBR-NRT (pourcentage du debit de la ligne : 100 = pas de surbooking)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..1100  

fclFrCeParGenBookingUbrThreshold 2.1.866.20.1.20.40.1.2.1.32
U% Bande passante reservee aux reseaux virtuels UBR (pourcentage du debit de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclFrCeParGenBookingVbrRtThreshold 2.1.866.20.1.20.40.1.2.1.33
V% Bande passante reservee aux COS VBR-RT (pourcentage du debit de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclFrCeParGenVoiceMaxTransitDelay 2.1.866.20.1.20.40.1.2.1.34
PDN transit delay
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclFrTerminalEquipment 2.1.866.20.1.20.40.2
OBJECT IDENTIFIER    

fclFrTeLogPortTable 2.1.866.20.1.20.40.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrTeLogPortEntry

fclFrTeLogPortEntry 2.1.866.20.1.20.40.2.1.1
An entry of fclFrTeLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrTeLogPortEntry  

fclFrTeLpLogPortId 2.1.866.20.1.20.40.2.1.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFrTeLpInterfaceId 2.1.866.20.1.20.40.2.1.1.2
IF Id (type ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..181  

fclFrTeLpLocalAddress 2.1.866.20.1.20.40.2.1.1.5
Adresse de localisation sur le plan d'adressage du routage (Numero d'abonne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclFrTeLpConfigId 2.1.866.20.1.20.40.2.1.1.10
Configuration FR-TE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclFrTeLpLmi 2.1.866.20.1.20.40.2.1.1.11
LMI
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), lmiUni(2), lmiNni(4)  

fclFrTeLpFragmentation 2.1.866.20.1.20.40.2.1.1.20
Segmentation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), optimized(3)  

fclFrTeLpLinkLayerConsolidation 2.1.866.20.1.20.40.2.1.1.21
CLLM
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclFrTeLpLogPortBackupEnabling 2.1.866.20.1.20.40.2.1.1.22
Secours
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onWhileActivity(2), onWhileDlciDown(3), onWhileLpDown(4)  

fclFrTeLpFragFrameSize 2.1.866.20.1.20.40.2.1.1.23
Taille des trames pour la Segmentation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), s128(2), s256(3), s512(5), s1024(9), s2048(17), s4096(33), s8192(65)  

fclFrTeLpBackupTimer 2.1.866.20.1.20.40.2.1.1.25
Tempo de retour su LS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2540  

fclFrTeParGenTable 2.1.866.20.1.20.40.2.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrTeParGenEntry

fclFrTeParGenEntry 2.1.866.20.1.20.40.2.4.1
An entry of fclFrTeParGenTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrTeParGenEntry  

fclFrTeParGenLogPortId 2.1.866.20.1.20.40.2.4.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFrTeParGenDlcSetupAlarmThreshold 2.1.866.20.1.20.40.2.4.1.30
A% Seuil alarmique d'acceptation des connexions (pourcentage du debit de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclFrTeParGenDlcSetupDiscardThreshold 2.1.866.20.1.20.40.2.4.1.31
R% Seuil de refus d'etablissement des DLC VBR-NRT (pourcentage du debit de la ligne : 100 = pas de surbooking)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..1100  

fclFrTeParGenBookingUbrThreshold 2.1.866.20.1.20.40.2.4.1.32
U% Bande passante reservee aux reseaux virtuels UBR (pourcentage du debit de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclFrTeParGenBookingVbrRtThreshold 2.1.866.20.1.20.40.2.4.1.33
V% Bande passante reservee aux COS VBR-RT (pourcentage du debit de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclFrTeParGenVoiceMaxTransitDelay 2.1.866.20.1.20.40.2.4.1.34
PDN transit delay
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclFrTeParGenDynamicEir 2.1.866.20.1.20.40.2.4.1.35
The value 'off' of this object means the Burst Exceeded object configuration is used in the traffic management plan with respect agreement traffic. The value 'on' of this object allows the whole connection to have a fair share of the line bandwidth in the proportion of the Commited Information Rate. In this case, the Burst Exceeded used in the traffic control is made dynamically from the unloaded line in the prorata of the CIR. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclFrTeParGenPredictionRoundTripDelay 2.1.866.20.1.20.40.2.4.1.36
Prediction du delai de propagation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclFrTeParGenNetworkBandwidth 2.1.866.20.1.20.40.2.4.1.37
Bande passante du reseau
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..34  

fclFrTeIsdnBackupTable 2.1.866.20.1.20.40.2.11
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrTeIsdnBackupEntry

fclFrTeIsdnBackupEntry 2.1.866.20.1.20.40.2.11.1
An entry of fclFrTeIsdnBackupTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrTeIsdnBackupEntry  

fclFrTeIsdnBackLogPortId 2.1.866.20.1.20.40.2.11.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFrTeIsdnBackIsdnInterfaceId 2.1.866.20.1.20.40.2.11.1.2
Interface RNIS locale id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclFrTeIsdnBackStatus 2.1.866.20.1.20.40.2.11.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFrTeIsdnRemotePeerTable 2.1.866.20.1.20.40.2.12
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrTeIsdnRemotePeerEntry

fclFrTeIsdnRemotePeerEntry 2.1.866.20.1.20.40.2.12.1
An entry of fclFrTeIsdnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrTeIsdnRemotePeerEntry  

fclFrTeIsdnRemLogPortId 2.1.866.20.1.20.40.2.12.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFrTeIsdnRemRemotePeerId 2.1.866.20.1.20.40.2.12.1.2
InterfaceRNIS distante id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclFrTeIsdnRemStatus 2.1.866.20.1.20.40.2.12.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFrTeIsdnRemPriority 2.1.866.20.1.20.40.2.12.1.8
Priorite
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

fclFrTeIsdnRemCallRetryCount 2.1.866.20.1.20.40.2.12.1.9
Nombre de tentatives d'appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclFrTeIsdnRemProtocol 2.1.866.20.1.20.40.2.12.1.15
Type de protocole
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER frse(1), frte(2), main-line-protocol(3)  

fclFrTeIsdnRemConfigId 2.1.866.20.1.20.40.2.12.1.16
Configuration id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclFrSwitchEquipment 2.1.866.20.1.20.40.3
OBJECT IDENTIFIER    

fclFrSeLogPortTable 2.1.866.20.1.20.40.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrSeLogPortEntry

fclFrSeLogPortEntry 2.1.866.20.1.20.40.3.1.1
An entry of fclFrSeLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrSeLogPortEntry  

fclFrSeLpLogPortId 2.1.866.20.1.20.40.3.1.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFrSeLpInterfaceId 2.1.866.20.1.20.40.3.1.1.2
IF Id (type ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..181  

fclFrSeLpConfigId 2.1.866.20.1.20.40.3.1.1.10
Configuration FR-SE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclFrSeLpLogPortBackupEnabling 2.1.866.20.1.20.40.3.1.1.22
Secours
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onWhileActivity(2), onWhileLpDown(3)  

fclFrSeLpBackupTimer 2.1.866.20.1.20.40.3.1.1.25
Tempo de retour sur LS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2540  

fclFrSeIsdnBackupTable 2.1.866.20.1.20.40.3.11
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrSeIsdnBackupEntry

fclFrSeIsdnBackupEntry 2.1.866.20.1.20.40.3.11.1
An entry of fclFrSeIsdnBackupTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrSeIsdnBackupEntry  

fclFrSeIsdnBackLogPortId 2.1.866.20.1.20.40.3.11.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFrSeIsdnBackIsdnInterfaceId 2.1.866.20.1.20.40.3.11.1.2
Interface RNIS locale id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclFrSeIsdnBackStatus 2.1.866.20.1.20.40.3.11.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFrSeIsdnRemotePeerTable 2.1.866.20.1.20.40.3.12
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrSeIsdnRemotePeerEntry

fclFrSeIsdnRemotePeerEntry 2.1.866.20.1.20.40.3.12.1
An entry of fclFrSeIsdnRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrSeIsdnRemotePeerEntry  

fclFrSeIsdnRemLogPortId 2.1.866.20.1.20.40.3.12.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFrSeIsdnRemRemotePeerId 2.1.866.20.1.20.40.3.12.1.2
Interface RNIS distante id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclFrSeIsdnRemStatus 2.1.866.20.1.20.40.3.12.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFrSeIsdnRemConfigId 2.1.866.20.1.20.40.3.12.1.4
Configuration FR-SE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclFrSeIsdnRemPriority 2.1.866.20.1.20.40.3.12.1.8
Priorite
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

fclFrSeIsdnRemCallRetryCount 2.1.866.20.1.20.40.3.12.1.9
Nombre de tentatives d'appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclFrSeInBIsdn 2.1.866.20.1.20.40.13
OBJECT IDENTIFIER    

fclFrSeInBIsdnLogPortTable 2.1.866.20.1.20.40.13.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrSeInBIsdnLogPortEntry

fclFrSeInBIsdnLogPortEntry 2.1.866.20.1.20.40.13.1.1
An entry of fclFrSeInBIsdnLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrSeInBIsdnLogPortEntry  

fclFrSeInBLpLogPortId 2.1.866.20.1.20.40.13.1.1.1
LP Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclFrSeInBLpIsdnInterfaceId 2.1.866.20.1.20.40.13.1.1.2
IF Id (type RNIS)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fclFrSeInBRemotePeerTable 2.1.866.20.1.20.40.13.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrSeInBRemotePeerEntry

fclFrSeInBRemotePeerEntry 2.1.866.20.1.20.40.13.2.1
An entry of fclFrSeInBRemotePeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrSeInBRemotePeerEntry  

fclFrSeInBRemRemoteAddress 2.1.866.20.1.20.40.13.2.1.1
Adresse visee
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclFrSeInBRemPeerId 2.1.866.20.1.20.40.13.2.1.2
Interface RNIS distante id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

fclFrSeInBRemStatus 2.1.866.20.1.20.40.13.2.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFrSeInBRemPriority 2.1.866.20.1.20.40.13.2.1.8
Priorite
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

fclFrSeInBRemCallRetryCount 2.1.866.20.1.20.40.13.2.1.9
Nb de tentatives appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fclFrSeInBRemConfigId 2.1.866.20.1.20.40.13.2.1.10
Configuration FR-SE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclFrPvcEndPoint 2.1.866.20.1.20.40.20
OBJECT IDENTIFIER    

fclFrPvcEndPointTable 2.1.866.20.1.20.40.20.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrPvcEndPointEntry

fclFrPvcEndPointEntry 2.1.866.20.1.20.40.20.1.1
An entry of fclFrPvcEndPointTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrPvcEndPointEntry  

fclFrPvcLinkType 2.1.866.20.1.20.40.20.1.1.1
Type de liaison (=logicalPort en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER logicalPort(1), bChannelIsdn(2)  

fclFrPvcLinkId 2.1.866.20.1.20.40.20.1.1.2
Liaison Id (=LogPortId en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclFrPvcDlci 2.1.866.20.1.20.40.20.1.1.3
DLCI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..991  

fclFrPvcStatus 2.1.866.20.1.20.40.20.1.1.4
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFrPvcCalledAddress 2.1.866.20.1.20.40.20.1.1.5
Adresse distante (non utilisee si encapsulation X25)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclFrPvcCallDirection 2.1.866.20.1.20.40.20.1.1.6
Mode d'appel (non utilise si encapsulation X25)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER calling(1), called(2), calledMulti(5), auto(3), datagram(4)  

fclFrPvcEncapsulation 2.1.866.20.1.20.40.20.1.1.7
Encapsulation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), lanProtocols(2), x25(3), sna(4), snaBan(5), voice(6)  

fclFrPvcBackupEnabling 2.1.866.20.1.20.40.20.1.1.10
Terminaison de PVC a secourir
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclFrPvcBackupDlci 2.1.866.20.1.20.40.20.1.1.11
DLCI de secours
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..991  

fclFrPvcTrafficManagementStrategy 2.1.866.20.1.20.40.20.1.1.20
Traffic management strategy
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER discardButNotDelay(1), delayButNotDiscard-Bc(3), delayButNotDiscard-BcBe(4)  

fclFrPvcNetworkTransport 2.1.866.20.1.20.40.20.1.1.21
FR Network transport
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER transparent(36), ansiT1-617-G(32)  

fclFrPvcQualityOfServiceTable 2.1.866.20.1.20.40.20.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrPvcQualityOfServiceEntry

fclFrPvcQualityOfServiceEntry 2.1.866.20.1.20.40.20.2.1
An entry of fclFrPvcQualityOfServiceTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrPvcQualityOfServiceEntry  

fclFrPvcQosLinkType 2.1.866.20.1.20.40.20.2.1.1
Type de liaison (=logicalPort en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER logicalPort(1), bChannelIsdn(2)  

fclFrPvcQosLinkId 2.1.866.20.1.20.40.20.2.1.2
Liaison Id (=LogPortId en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclFrPvcQosDlci 2.1.866.20.1.20.40.20.2.1.3
DLCI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..991  

fclFrPvcQosCos 2.1.866.20.1.20.40.20.2.1.5
COS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1), vbr-rt(2)  

fclFrPvcQosInBc 2.1.866.20.1.20.40.20.2.1.11
Entrant BC
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclFrPvcQosInBe 2.1.866.20.1.20.40.20.2.1.12
Entrant BE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclFrPvcQosInCir 2.1.866.20.1.20.40.20.2.1.13
Entrant CIR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclFrPvcQosInMinCir 2.1.866.20.1.20.40.20.2.1.14
Entrant CIR mini
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclFrPvcQosOutBc 2.1.866.20.1.20.40.20.2.1.21
Sortant BC
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclFrPvcQosOutBe 2.1.866.20.1.20.40.20.2.1.22
Sortant BE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclFrPvcQosOutCir 2.1.866.20.1.20.40.20.2.1.23
Sortant CIR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclFrPvcQosOutMinCir 2.1.866.20.1.20.40.20.2.1.24
Sortant CIR mini
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclFrPvcX25EncapsulationTable 2.1.866.20.1.20.40.20.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrPvcX25EncapsulationEntry

fclFrPvcX25EncapsulationEntry 2.1.866.20.1.20.40.20.10.1
An entry of fclFrPvcX25EncapsulationTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrPvcX25EncapsulationEntry  

fclFrPvcX25LinkType 2.1.866.20.1.20.40.20.10.1.1
Type de liaison (=logicalPort en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER logicalPort(1), bChannelIsdn(2)  

fclFrPvcX25LinkId 2.1.866.20.1.20.40.20.10.1.2
Liaison Id (=LogPortId en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclFrPvcX25Dlci 2.1.866.20.1.20.40.20.10.1.3
DLCI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..991  

fclFrPvcX25AssociatedAddress 2.1.866.20.1.20.40.20.10.1.5
Adresse associee
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclFrPvcX25InterNodeConfigId 2.1.866.20.1.20.40.20.10.1.10
Configuration X25
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclFrPvcSnaEncapsulationTable 2.1.866.20.1.20.40.20.11
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrPvcSnaEncapsulationEntry

fclFrPvcSnaEncapsulationEntry 2.1.866.20.1.20.40.20.11.1
An entry of fclFrPvcSnaEncapsulationTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrPvcSnaEncapsulationEntry  

fclFrPvcSnaLinkType 2.1.866.20.1.20.40.20.11.1.1
Type de liaison (=logicalPort en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER logicalPort(1), bChannelIsdn(2)  

fclFrPvcSnaLinkId 2.1.866.20.1.20.40.20.11.1.2
Liaison Id (=LogPortId en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclFrPvcSnaDlci 2.1.866.20.1.20.40.20.11.1.3
DLCI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..991  

fclFrPvcSnaConnTestEnabling 2.1.866.20.1.20.40.20.11.1.5
Initiative d'etablissement de connexion par une trame test
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclFrPvcSnaLevel3Pid 2.1.866.20.1.20.40.20.11.1.10
L3 PID
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER subArea(1), peripheral(2), appn(3)  

fclFrPvcSnaDestinationSap 2.1.866.20.1.20.40.20.11.1.11
DSAP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclFrPvcSnaSourceSap 2.1.866.20.1.20.40.20.11.1.12
SSAP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fclFrPvcSnaT1ReplyTimer 2.1.866.20.1.20.40.20.11.1.20
Timer T1 attente une trame U
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25000  

fclFrPvcSnaN2RetryCount 2.1.866.20.1.20.40.20.11.1.21
N2 Nombre maximum de retransmissions
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fclFrPvcSnaT2ReceiverAckTimer 2.1.866.20.1.20.40.20.11.1.22
Timer T2 acquittement des trames I
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..15000  

fclFrPvcSnaN3AcknowledgedCount 2.1.866.20.1.20.40.20.11.1.23
N3 Nombre de trames ok avant acquittement
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fclFrPvcSnaNwIncrementAckCount 2.1.866.20.1.20.40.20.11.1.24
NW congestion : nombre de trames ok avant incrementer la fenetre de travail
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fclFrPvcSnaTwTransmitWinSize 2.1.866.20.1.20.40.20.11.1.25
TW Fenetre en emission
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fclFrPvcSnaRwReceiveWinSize 2.1.866.20.1.20.40.20.11.1.26
RW fenetre reception
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fclFrSnaBan 2.1.866.20.1.20.40.20.12
OBJECT IDENTIFIER    

fclFrNbStationDlci 2.1.866.20.1.20.40.20.12.1
OBJECT IDENTIFIER    

fclFrNbStationByDlci 2.1.866.20.1.20.40.20.12.1.1
Nombre de stations par DLCI BAN Frontal
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nb0(1), nb16(2), nb32(3), nb64(4), nb128(5)  

fclFrPvcSnaBanEncapsulationTable 2.1.866.20.1.20.40.20.12.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrPvcSnaBanEncapsulationEntry

fclFrPvcSnaBanEncapsulationEntry 2.1.866.20.1.20.40.20.12.10.1
An entry of fclFrPvcSnaBanEncapsulationTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrPvcSnaBanEncapsulationEntry  

fclFrPvcSnaBanLinkType 2.1.866.20.1.20.40.20.12.10.1.1
Type de liaison (=logicalPort en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER logicalPort(1), bChannelIsdn(2)  

fclFrPvcSnaBanLinkId 2.1.866.20.1.20.40.20.12.10.1.2
Liaison Id (=LogPortId en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclFrPvcSnaBanDlci 2.1.866.20.1.20.40.20.12.10.1.3
DLCI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..991  

fclFrPvcSnaBanPuId 2.1.866.20.1.20.40.20.12.10.1.10
Pu id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1999  

fclFrPvcSnaBanConnTestEnabling 2.1.866.20.1.20.40.20.12.10.1.11
Initiative d'etablissement de connexion par une trame test
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  


fclFrPvcSnaBanT1ReplyTimer 2.1.866.20.1.20.40.20.12.10.1.20
Timer T1 attente une trame U
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25000  

fclFrPvcSnaBanN2RetryCount 2.1.866.20.1.20.40.20.12.10.1.21
N2 Nombre maximum de retransmissions
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fclFrPvcSnaBanT2ReceiverAckTimer 2.1.866.20.1.20.40.20.12.10.1.22
Timer T2 acquittement des trames I
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..15000  

fclFrPvcSnaBanN3AcknowledgedCount 2.1.866.20.1.20.40.20.12.10.1.23
N3 Nombre de trames ok avant acquittement
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fclFrPvcSnaBanNwIncrementAckCount 2.1.866.20.1.20.40.20.12.10.1.24
NW congestion : nombre de trames ok avant incrementer la fenetre de travail
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fclFrPvcSnaBanTwTransmitWinSize 2.1.866.20.1.20.40.20.12.10.1.25
TW Fenetre en emission
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fclFrPvcSnaBanRwReceiveWinSize 2.1.866.20.1.20.40.20.12.10.1.26
RW fenetre reception
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fclFrPvcSnaBanMinRecallTimer 2.1.866.20.1.20.40.20.12.10.1.27
Minimum recall timer
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fclFrPvcSpecific 2.1.866.20.1.20.40.25
OBJECT IDENTIFIER    

fclFrPvcTunEndPointTable 2.1.866.20.1.20.40.25.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrPvcTunEndPointEntry

fclFrPvcTunEndPointEntry 2.1.866.20.1.20.40.25.1.1
An entry of fclFrPvcTunEndPointTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrPvcTunEndPointEntry  

fclFrPvcTunLinkType 2.1.866.20.1.20.40.25.1.1.1
Type de liaison (=logicalPort en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER logicalPort(1), bChannelIsdn(2)  

fclFrPvcTunLinkId 2.1.866.20.1.20.40.25.1.1.2
Liaison Id (=LogPortId en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..249  

fclFrPvcTunDlci 2.1.866.20.1.20.40.25.1.1.3
DLCI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..991  

fclFrPvcTunStatus 2.1.866.20.1.20.40.25.1.1.4
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFrPvcTunInCir 2.1.866.20.1.20.40.25.1.1.5
Entrant CIR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclFrPvcTunOutCir 2.1.866.20.1.20.40.25.1.1.6
Sortant CIR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclFrPvcTunBackupEnabling 2.1.866.20.1.20.40.25.1.1.10
Terminaison de PVC a secourir
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclFrPvcTunBackupDlci 2.1.866.20.1.20.40.25.1.1.11
DLCI de secours
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..991  

fclFrPvcTunAssociatedAddress 2.1.866.20.1.20.40.25.1.1.15
Adresse associee
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fclFrPvcTunFrseConfiguration 2.1.866.20.1.20.40.25.1.1.20
Configuration FRSE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclFrameRelayBackup 2.1.866.20.1.20.40.27
OBJECT IDENTIFIER    

fclFrBackupTable 2.1.866.20.1.20.40.27.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrBackupEntry

fclFrBackupEntry 2.1.866.20.1.20.40.27.1.1
An entry of fclFrBackupTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrBackupEntry  

fclFrMainLPId 2.1.866.20.1.20.40.27.1.1.1
LP principale
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

fclFrMainDlci 2.1.866.20.1.20.40.27.1.1.2
DLCI principal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

fclFrBackupLPId 2.1.866.20.1.20.40.27.1.1.3
LP secours
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

fclFrBackupDlci 2.1.866.20.1.20.40.27.1.1.4
DLCI secours
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

fclFrBackupStatus 2.1.866.20.1.20.40.27.1.1.5
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFrConfigurationCeTe 2.1.866.20.1.20.40.30
OBJECT IDENTIFIER    

fclFrConfigCeTeTable 2.1.866.20.1.20.40.30.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrConfigCeTeEntry

fclFrConfigCeTeEntry 2.1.866.20.1.20.40.30.1.1
An entry of fclFrConfigCeTeTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrConfigCeTeEntry  

fclFrCfcConfigId 2.1.866.20.1.20.40.30.1.1.1
Configuration id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCfcStatus 2.1.866.20.1.20.40.30.1.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFrCfcDescription 2.1.866.20.1.20.40.30.1.1.3
Description
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

fclFrCfcProfileId 2.1.866.20.1.20.40.30.1.1.4
The value of this object is the profile number used to automatically valorize all the FR parameters in an entry of the two tables which composes FR-CE or FR-TE configurations (see fclFrCfcConfigId). The possible values are : 84 FRTE interface, 85 FRCE interface, If it is unused, the value of this parameter is '255'. The default value is '85' (meaning that default values of FR parameters are those pre-defined in profile number 85).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCfcModificationCount 2.1.866.20.1.20.40.30.1.1.5
Nombre de parametres modifies par rapport au profil
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fclFrCfcGeneralParameterTable 2.1.866.20.1.20.40.30.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrCfcGeneralParameterEntry

fclFrCfcGeneralParameterEntry 2.1.866.20.1.20.40.30.10.1
An entry of fclFrCfcGeneralParameterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrCfcGeneralParameterEntry  

fclFrCfcGenConfigId 2.1.866.20.1.20.40.30.10.1.1
Configuration id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCfcGenMinimumRecallTimer 2.1.866.20.1.20.40.30.10.1.20
Tempo de slow call (Tsc) en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2540  

fclFrCfcGenInactivityCheckDelay 2.1.866.20.1.20.40.30.10.1.21
Inactivity check delay (Ta) en minutes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..254  

fclFrCfcGenInactivityTimer 2.1.866.20.1.20.40.30.10.1.22
Inactivity timer (Tb) en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2540  

fclFrCfcGenUnuseTimer 2.1.866.20.1.20.40.30.10.1.23
Tempo 0 CV en secondes (0 = pas de surveillance)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2550  

fclFrCfcGenSVC 2.1.866.20.1.20.40.30.10.1.24
SVC
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

fclFrCfcSignallingParameterTable 2.1.866.20.1.20.40.30.15
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrCfcSignallingParameterEntry

fclFrCfcSignallingParameterEntry 2.1.866.20.1.20.40.30.15.1
An entry of fclFrCfcSignallingParameterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrCfcSignallingParameterEntry  

fclFrCfcSigConfigId 2.1.866.20.1.20.40.30.15.1.1
Configuration id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCfcSigOuputTimeout 2.1.866.20.1.20.40.30.15.1.2
Tempo de surveillance de ligne en emission en millisecondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..51000  

fclFrCfcSigSignalOutputWinSize 2.1.866.20.1.20.40.30.15.1.3
Fenetre d'emission DLCI de signalisation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclFrCfcSigN200RetransMaxCount 2.1.866.20.1.20.40.30.15.1.5
N 200 : Nombre de repetition trames
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclFrCfcSigT200RetransTimer 2.1.866.20.1.20.40.30.15.1.6
T 200 : Tempo de retransmission en millisecondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..25500  

fclFrCfcSigT203InactivityTimer 2.1.866.20.1.20.40.30.15.1.7
T 203 : Polling RR en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fclFrCfcSigT303SetupResponseTimer 2.1.866.20.1.20.40.30.15.1.11
T 303 : Tempo attente de reponse a un etablissement sortant en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclFrCfcSigT305DisconnectResponseTimer 2.1.866.20.1.20.40.30.15.1.12
T 305 : Tempo attente de reponse a une demande de deconnexion en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclFrCfcSigT308ReleaseResponseTimer 2.1.866.20.1.20.40.30.15.1.13
T 308 : Tempo attente de reponse a une demande de liberation en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclFrCfcSigT310CallProceedingTimer 2.1.866.20.1.20.40.30.15.1.15
T 310 : Tempo entre un appel recu et une alerte ou une connexion en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclFrCfcSigT316RestartAcknowledgeTimer 2.1.866.20.1.20.40.30.15.1.17
T 316 : Tempo de reponse au RESTART en secondes (0 = pas de RESTART)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fclFrCfcSigConversionAimedPoint 2.1.866.20.1.20.40.30.15.1.10
Conversion adresse : point vise
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclFrCfcEiCodingTable 2.1.866.20.1.20.40.30.16
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrCfcEiCodingEntry

fclFrCfcEiCodingEntry 2.1.866.20.1.20.40.30.16.1
An entry of fclFrCfcEiCodingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrCfcEiCodingEntry  

fclFrCfcEiCodConfigId 2.1.866.20.1.20.40.30.16.1.1
Configuration id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCfcEiCodCalledTypNum 2.1.866.20.1.20.40.30.16.1.2
Called Type of number
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), international-number(2), national-number(3), complementary-address(4), network-specific(5)  

fclFrCfcEiCodCalledNumPlanId 2.1.866.20.1.20.40.30.16.1.3
Called Numbering plan identification
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), e164(2), x121(3), private-num-plan(9)  

fclFrCfcEiCodCallingTypNum 2.1.866.20.1.20.40.30.16.1.4
Calling Type of number
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), international-number(2), national-number(3), complementary-address(4), network-specific(5)  

fclFrCfcEiCodCallingNumPlanId 2.1.866.20.1.20.40.30.16.1.5
Calling Numbering plan identification
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), e164(2), x121(3), private-num-plan(9)  

fclFrCfcLmiParameterTable 2.1.866.20.1.20.40.30.21
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrCfcLmiParameterEntry

fclFrCfcLmiParameterEntry 2.1.866.20.1.20.40.30.21.1
An entry of fclFrCfcLmiParameterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrCfcLmiParameterEntry  

fclFrCfcLmiConfigId 2.1.866.20.1.20.40.30.21.1.1
Configuration id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCfcLmiDlci 2.1.866.20.1.20.40.30.21.1.2
DLCI utilise
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dlci0(1), dlci1023(2)  

fclFrCfcLmiStandard 2.1.866.20.1.20.40.30.21.1.3
Standard LMI
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ansiT1-617d(1), itutQ933a(2)  

fclFrCfcLmiAccessibilityCondition 2.1.866.20.1.20.40.30.21.1.4
Critere de disponibilite
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fast(1), n393(2)  

fclFrCfcLmiN391FullStatusPollCount 2.1.866.20.1.20.40.30.21.1.5
N 391 (User) Cycle interrogation prealable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fclFrCfcLmiN392ErrorThreshold 2.1.866.20.1.20.40.30.21.1.6
N 392 (User/Net) Seuil erreur
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

fclFrCfcLmiN393MonitoredEventCount 2.1.866.20.1.20.40.30.21.1.7
N393 (User/Net) Compteur des evenements controles
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

fclFrCfcLmiT391LinkIntegPollTimer 2.1.866.20.1.20.40.30.21.1.8
T 391 (User) Tempo de polling status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

fclFrCfcLmiT392PollingVerifTimer 2.1.866.20.1.20.40.30.21.1.9
T 392 (Net) Tempo attente de la demande etat
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

fclFrCfcLmiAsynchronousStatusReport 2.1.866.20.1.20.40.30.21.1.10
Envoi du status asynchrone
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclFrConfigurationSe 2.1.866.20.1.20.40.40
OBJECT IDENTIFIER    

fclFrConfigSeTable 2.1.866.20.1.20.40.40.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrConfigSeEntry

fclFrConfigSeEntry 2.1.866.20.1.20.40.40.1.1
An entry of fclFrConfigSeTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrConfigSeEntry  

fclFrCfsConfigId 2.1.866.20.1.20.40.40.1.1.1
Configuration id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCfsStatus 2.1.866.20.1.20.40.40.1.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclFrCfsDescription 2.1.866.20.1.20.40.40.1.1.3
Description
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

fclFrCfsProfileId 2.1.866.20.1.20.40.40.1.1.4
The value of this object is the profile number used to automatically valorize all the FR parameters in an entry of the two tables which composes FR-SE configurations (see fclFrCfsConfigId). The possible values are : 80 FRSE interface. If it is unused, the value of this parameter is '255'. The default value is '80' (meaning that default values of FR parameters are those pre-defined in profile number 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCfsModificationCount 2.1.866.20.1.20.40.40.1.1.5
Nombre de parametres modifies par rapport au profil
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fclFrCfsGeneralParameterTable 2.1.866.20.1.20.40.40.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrCfsGeneralParameterEntry

fclFrCfsGeneralParameterEntry 2.1.866.20.1.20.40.40.10.1
An entry of fclFrCfsGeneralParameterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrCfsGeneralParameterEntry  

fclFrCfsGenConfigId 2.1.866.20.1.20.40.40.10.1.1
Configuration id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCfsGenCallReturnTransmission 2.1.866.20.1.20.40.40.10.1.15
Retour d'appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onIfFailed(3), onIfFailedOrBusy(4)  

fclFrCfsGenUnuseTimer 2.1.866.20.1.20.40.40.10.1.20
Tempo 0 CV en secondes (0 = pas de surveillance)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2550  

fclFrCfsGenDlcSetupAlarmThreshold 2.1.866.20.1.20.40.40.10.1.30
A% Seuil alarmique d'acceptation des connexions (pourcentage du debit de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclFrCfsGenDlcSetupDiscardThreshold 2.1.866.20.1.20.40.40.10.1.31
R% Seuil de refus d'etablissement des DLC VBR-NRT (pourcentage du debit de la ligne : 100 = pas de surbooking)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..1100  

fclFrCfsGenBookingUbrThreshold 2.1.866.20.1.20.40.40.10.1.32
U% Bande passante reservee aux reseaux virtuels UBR (pourcentage du debit de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclFrCfsGenBookingVbrRtThreshold 2.1.866.20.1.20.40.40.10.1.33
V% Bande passante reservee aux COS VBR-RT (pourcentage du debit de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fclFrCfsGenBehavior 2.1.866.20.1.20.40.40.10.1.40
Type de comportement
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), svc-endpoint(2)  

fclFrCfsGenDynamicEir 2.1.866.20.1.20.40.40.10.1.41
The value 'off' of this object means the Burst Exceeded object configuration is used in the traffic management plan with respect agreement traffic. The value 'on' of this object allows the whole connection to have a fair share of the line bandwidth in the proportion of the Commited Information Rate. In this case, the Burst Exceeded used in the traffic control is made dynamically from the unloaded line in the prorata of the CIR. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclFrCfsGenPredictionRoundTripDelay 2.1.866.20.1.20.40.40.10.1.42
Prediction du delai de propagation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fclFrCfsGenNetworkBandwidth 2.1.866.20.1.20.40.40.10.1.43
Bande passante du reseau
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..34  

fclFrCfsSignallingTable 2.1.866.20.1.20.40.40.20
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclFrCfsSignallingEntry

fclFrCfsSignallingEntry 2.1.866.20.1.20.40.40.20.1
An entry of fclFrCfsSignallingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclFrCfsSignallingEntry  

fclFrCfsSigConfigId 2.1.866.20.1.20.40.40.20.1.1
Configuration id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclFrCfsSigOuputTimeout 2.1.866.20.1.20.40.40.20.1.2
Tempo de surveillance de ligne en emission en millisecondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..51000  

fclFrCfsSigSignalOutputWinSize 2.1.866.20.1.20.40.40.20.1.3
Fenetre d'emission DLCI de signalisation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclFrCfsSigN200RetransMaxCount 2.1.866.20.1.20.40.40.20.1.5
N 200 : Nombre de repetition trames
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclFrCfsSigT200RetransTimer 2.1.866.20.1.20.40.40.20.1.6
T 200 : Tempo de retransmission en millisecondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..25500  

fclFrCfsSigT203InactivityTimer 2.1.866.20.1.20.40.40.20.1.7
T 203 : Polling RR en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fclFrCfsSigT303SetupResponseTimer 2.1.866.20.1.20.40.40.20.1.11
T 303 : Tempo attente de reponse a un etablissement sortant en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclFrCfsSigT305DisconnectResponseTimer 2.1.866.20.1.20.40.40.20.1.12
T 305 : Tempo attente de reponse a une demande de deconnexion en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclFrCfsSigT308ReleaseResponseTimer 2.1.866.20.1.20.40.40.20.1.13
T 308 : Tempo attente de reponse a une demande de liberation en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclFrCfsSigT310CallProceedingTimer 2.1.866.20.1.20.40.40.20.1.15
T 310 : Tempo entre un appel recu et une alerte ou une connexion en secondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fclFrCfsSigT316RestartAcknowledgeTimer 2.1.866.20.1.20.40.40.20.1.17
T 316 : Tempo de reponse au RESTART en secondes (0 = pas de RESTART)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  


fclInterUnitLinkTable 2.1.866.20.1.20.45.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclInterUnitLinkEntry

fclInterUnitLinkEntry 2.1.866.20.1.20.45.1.1
An entry of fclInterUnitLinkTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclInterUnitLinkEntry  

fclIulLogPortId 2.1.866.20.1.20.45.1.1.1
LP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 36..41  

fclIulInterfaceId 2.1.866.20.1.20.45.1.1.2
IF id (type LIU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 36..41  

fclIulCallReturnTransmission 2.1.866.20.1.20.45.1.1.5
Autorisation retour d'appel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(3)  

fclIulConversionAimedPoint 2.1.866.20.1.20.45.1.1.10
Conversion adresse : point vise
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclIulConversionIncomingCall 2.1.866.20.1.20.45.1.1.11
Conversion d'adresse sur appel entrant
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fclIulConversionOutgoingCall 2.1.866.20.1.20.45.1.1.12
Conversion adresse sur appel sortant
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fclIulConversionAddressCheck 2.1.866.20.1.20.45.1.1.13
Conversion adresse : controle de la presence dans les tables de conversion
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(4)  

fclX25Configurations 2.1.866.20.1.20.50
OBJECT IDENTIFIER    

fclX25ConfigAccess 2.1.866.20.1.20.50.1
OBJECT IDENTIFIER    

fclX25ConfigAccessTable 2.1.866.20.1.20.50.1.1
This table contains the X25 access configurations used by X25 access links.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25ConfigAccessEntry

fclX25ConfigAccessEntry 2.1.866.20.1.20.50.1.1.1
An entry of fclX25ConfigAccessTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25ConfigAccessEntry  

fclX25CfaConfigId 2.1.866.20.1.20.50.1.1.1.1
The value of this object identifies one and only one X25 access configuration. This configuration may be referenced by fclX25AccX25AccessConfigId, fclX25InDX25AccessConfigId, fclX25InDIsdnRemX25AccConfigId or fclX25InBRemX25ConfigId. The possible values are : '0..199. If it is unused, the value of this parameter is '255'. The X25 access configuration parameters are described in : fclX25CfaDataLinkNetworkTable : data link and network levels, fclX25CfaFacilityTable : facility level, fclX25CfaNegotiatedFacilityTable : facility level (negotiaitions), fclX25CfaSignallingTable : signalling level, fclX25CfaServiceTable : services level. When creating a new configuration each parameter takes its default value. Setting a profile allows the user to fill all the parameters with values pre-defined in this profile but each one may also be individually modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfaStatus 2.1.866.20.1.20.50.1.1.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25CfaDescription 2.1.866.20.1.20.50.1.1.1.3
The value of this object stores a text description of the X25 access configuration elaborated by the user. This description may contains from 0 to 32 characters. The default value is 'Subscriber with facilities'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

fclX25CfaProfileId 2.1.866.20.1.20.50.1.1.1.4
The value of this object is the profile number used to automatically valorize all the X25 parameters in an entry of the five tables which composes X25 access configurations (see fclX25CfaConfigId). The possible values are : 00 Public network with facilities, 01 Subscribers without facilities, 02 Subscribers with facilities, 03 PSTN, 19 PSTN VX.32 (TRANSPAC), If it is unused, the value of this parameter is '255'. The default value is '2' (meaning that default values of X25 parameters are those pre-defined in profile number 02).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfaModificationCount 2.1.866.20.1.20.50.1.1.1.5
The value of this object indicates how many X25 parameters have not the value defined in the profile specified by fclX25CfaProfileId (i.e how many individual modifications).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fclX25CfaDataLinkNetworkTable 2.1.866.20.1.20.50.1.10
This table contains the data link and network levels parameters of X25 access configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfaDataLinkNetworkEntry

fclX25CfaDataLinkNetworkEntry 2.1.866.20.1.20.50.1.10.1
An entry of fclX25CfaDataLinkNetworkTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfaDataLinkNetworkEntry  

fclX25CfaDlnConfigId 2.1.866.20.1.20.50.1.10.1.1
The value of this object identifies one and only one X25 access configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfaDlnStationType 2.1.866.20.1.20.50.1.10.1.2
The value of this object defines the type of the interface at the data link layer (and not at the physical layer which is defined in fcfLineType). The equipment can acts as a DTE (Data Terminal Equipment) or as a DCE (Data Circuit-terminating Equipment). The default value is 'dce'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2)  

fclX25CfaDlnNetworkType 2.1.866.20.1.20.50.1.10.1.3
The value of this parameter defines the type of the network which the equipment is working with. The authorized values are : x25, 'transpac' in France, 'telenet' in the USA, 'tymnet' in the USA, 'infoSwitch' in Canada, 'datapac' in Canada, 'dn1' in the Netherlands, 'pss' in Great Britain, 'germanyDatexP' in Germany, 'dcs' in Belgium, 'itapac' in Italy, 'austpac' in Australia, 'uninet' in the USA, 'telepac' in Switzerland, 'iberpac' in Spain, 'datapak' in Sweden, 'helpac' in Greece, 'entel' in Argentina, 'austriaDatexP' in Austria. The default value is 'transpac'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER x25(1), transpac(5), telenet(9), tymnet(13), infoSwitch(17), datapac(21), dn1(25), pss(29), germanyDatexP(33), dcs(37), itapac(41), austpac(45), uninet(53), telepac(61), iberpac(65), datapak(69), helpac(73), entel(77), austriaDatexP(93)  

fclX25CfaDlnN2RetryCount 2.1.866.20.1.20.50.1.10.1.5
The value of this object indicates the maximum number (N2) of attempts made by the equipment to complete the successfull transmission of a frame. The authorized values are '2..250'. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..250  

fclX25CfaDlnT1AcknowledgeTimer 2.1.866.20.1.20.50.1.10.1.6
The value of this object indicates the period (T1), in milliseconds, at the end of which retransmission of a frame may be initiated. The authorized values are '200..25000'. The default value is '1600'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 200..25000  

fclX25CfaDlnT2AcknwledgeDelayTimer 2.1.866.20.1.20.50.1.10.1.7
The value of this object indicates the amount of time available (T2), in milliseconds, before the acknowledging frame must be initiated. This parameter must be smaller than T1. The authorized values are '100..12700'. The default value is '100'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..12700  

fclX25CfaDlnKWindowSize 2.1.866.20.1.20.50.1.10.1.8
The value of this object indicates the maximum number (K) of sequentially numbered I frames that the equipment may have outstanding (i.e.. unacknowledged) at any given time. The authorized values are '1..127'. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fclX25CfaDlnEachPacketAcknowledgement 2.1.866.20.1.20.50.1.10.1.9
The value of this object indicates whether each frame is acknowledged or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfaDlnLowestIncomingChannel 2.1.866.20.1.20.50.1.10.1.10
The value of this object is the Lowest Incoming one-way logical Channel (LIC).The authorized values are '0..4095'. The default value is '26'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

fclX25CfaDlnIncomingChannelCount 2.1.866.20.1.20.50.1.10.1.11
The value of this object is the Number of Incoming one-way logical Channels (NIC). So the Highest Incoming one-way logical Channel (HIC) is : HIC = LIC + NIC - 1. The authorized values are '0..4096'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4096  

fclX25CfaDlnLowestTwoWayChannel 2.1.866.20.1.20.50.1.10.1.15
The value of this object is the Lowest Two-way logical Channel (LTC). The authorized values are '0..4095'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

fclX25CfaDlnTwoWayChannelCount 2.1.866.20.1.20.50.1.10.1.16
The value of this object is the Number of Two-way logical Channels. So the Highest Two-way logical Channel (HTC) is : HTC = LTC + NTC - 1. The authorized values are '0..4096'. The default value is '25'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4096  

fclX25CfaDlnLowestOutgoingChannel 2.1.866.20.1.20.50.1.10.1.17
The value of this object is the Lowest Outgoing one-way logical Channel (LOC). The authorized values are '0..4095'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

fclX25CfaDlnOutgoingChannelCount 2.1.866.20.1.20.50.1.10.1.18
The value of this object is the Number of Outgoing one-way logical Channels (NOC). So the Highest Outgoing one-way logical Channel (HOC) is : HOC = LOC + NOC - 1. The authorized values are '0..4096'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4096  

fclX25CfaDlnOutgoingChannelNumbering 2.1.866.20.1.20.50.1.10.1.19
The value of this object indicates whether the equipment searches for a logical channel from the lowest one to the highest one (incremental order) or from the highest one to the lowest one (decremental order). The default value is 'incremental'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER decremental(1), incremental(2)  

fclX25CfaDlnDBitModification 2.1.866.20.1.20.50.1.10.1.30
The value of this object indicates how the equipment manages the D bit (Delivery Confirmation Bit). When it receives a call from a DTE wishing to receive an end-to-end acknowledgement of delivery the equipment may : ignore this D bit procedure ('off' value), ??? indicate clearing ('clear' value), ??? ('on' value), The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(2), on(3)  

fclX25CfaFacilityTable 2.1.866.20.1.20.50.1.20
This table contains the facility level parameters of X25 access configurations (except fast select, throughput class, packet size and window size which take place in fclX25CfaNegotiatedFacilityTable).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfaFacilityEntry

fclX25CfaFacilityEntry 2.1.866.20.1.20.50.1.20.1
An entry of fclX25CfaFacilityTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfaFacilityEntry  

fclX25CfaFacConfigId 2.1.866.20.1.20.50.1.20.1.1
The value of this object identifies one and only one X25 access configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfaFacClosedUserGroup 2.1.866.20.1.20.50.1.20.1.2
The value of this object specifies the behaviour of the equipment with respect to the Closed User Group (CUG) facility. There are 4 possible values : noCheck : the CUG is not checked, clear : clearing if the CUG is present in a call packet from a subscriber, subscribe : clearing if the CUG is not present in a call packet from a subcriber, subscribeAndRemove : clearing if the CUG is not present in a call packet from a subcriber, suppression of the CUG in a call packet to a subcriber. The default value is 'noCheck'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(2), clear(1), subscribe(3), subscribeAndRemove(4)  

fclX25CfaFacReverseCharging 2.1.866.20.1.20.50.1.20.1.5
The value of this object specifies the behaviour of the equipment with respect to the reverse charging facility. If the called subscriber doesn't accept the reverse charging, the call is not transmitted and a clear is sent. The default value is 'refuse'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER refuse(1), accept(2)  

fclX25CfaFacTransitDelay 2.1.866.20.1.20.50.1.20.1.6
The value of this object specifies the behaviour of the equipment with respect to the transit delay facility. The authorized values are : noCheck : no checking clear : clearing subscribe : according to the following table : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | packet |from network|from subscriber| |~~~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~~~~| | call |no checking | no checking | |~~~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~~~~| |call connected|no checking | clearing (2) | |~~~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~~~~| | clear |clearing (1)| clearing (2) | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ (1) : diagnostic = 05 41 (2) : diagnostic to local equipment = 03 41, diagnostic to remote equipment = 03 41 The default value is 'noCheck'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(1), clear(3), subscribe(2)  

fclX25CfaFacOutputMarkers 2.1.866.20.1.20.50.1.20.1.7
The value of this object specifies the behaviour of the equipment with respect to the outgoing facility markers. The authorized values are : noCheck : no checking, remove : the markers are not transmitted, check : according to the following table : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | packet | facility marker | | |~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | 0000 (1) | 00FF (2) | 000F (3) | |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | call |no checking |clearing (5)|no checking| |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | call | | | | |connected|clearing (4)|no checking |no checking| |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | clear | - | - |no checking| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ (1) : registration codes, non-x25 facilities provided by the network in case of intranetwork calls, non-x25 facilities provided by the network to which the calling DTE is connected in case of internetwork calls (2) : non-x25 facilities provided by the network to which the calling DTE is connected in case of intranetwork calls (3) : CCITT-specified DTE facilities (4) : diagnostic to local equipment = 03 42, diagnostic to remote equipment = 11 42 (5) : diagnostic to local equipment = 03 42 The default value is 'noCheck'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(1), check(2), remove(3)  

fclX25CfaFacInputMarkers 2.1.866.20.1.20.50.1.20.1.8
Marqueurs en reception
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(1), check(2), remove(3)  

fclX25CfaFacOutputUnknownFacility 2.1.866.20.1.20.50.1.20.1.10
The value of this object specifies the behaviour of the equipment with respect to an outgoing unknown facility. The authorized values are : noCheck : no checking, remove : the unknown facility is not sent, clear : clearing. The default value is 'noCheck'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(1), clear(3), remove(2)  

fclX25CfaFacInputUnknownFacility 2.1.866.20.1.20.50.1.20.1.11
The value of this object specifies the behaviour of the equipment with respect to an incoming unknown facility. The authorized values are : noCheck : no checking, remove : the unknown facility is not sent, clear : clearing. The default value is 'noCheck'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(1), clear(3), remove(2)  

fclX25CfaNegotiatedFacilityTable 2.1.866.20.1.20.50.1.21
This table contains the facility level parameters of X25 access configurations (except closed user group, reverse charging, transit delay, markers, unknown facility which take place in fclX25CfaFacilityTable).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfaNegotiatedFacilityEntry

fclX25CfaNegotiatedFacilityEntry 2.1.866.20.1.20.50.1.21.1
An entry of fclX25CfaNegotiatedFacilityTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfaNegotiatedFacilityEntry  

fclX25CfaNegConfigId 2.1.866.20.1.20.50.1.21.1.1
The value of this object identifies one and only one X25 access configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfaNegOutputFastSelect 2.1.866.20.1.20.50.1.21.1.2
The value of this object specifies the behaviour of the equipment with respect to the fast select facility in outgoing call. The authorized values are 'noCheck' (no checking), 'clear' (clearing), 'subscribe'. The default value is 'noCheck'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(3), clear(1), subscribe(2)  

fclX25CfaNegInputFastSelect 2.1.866.20.1.20.50.1.21.1.3
The value of this object is the maximum size of the call user data field in a received call request packet not containing the fast select facility. The authorized values are 'subscribe' (up to 16 bytes) or 'longUserData' (up to 128 bytes). The default value is 'subscribe'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER subscribe(2), longUserData(4)  

fclX25CfaNegThroughputClass 2.1.866.20.1.20.50.1.21.1.10
The value of this object indicates whether the subscriber connected to the link has subscribed to throughput class negociation facility or not. The authorized values are 'clear' (not subscriber) or 'subscribe'. The default value is 'subscribe'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), subscribe(2)  

fclX25CfaNegDefOutThroughputClass 2.1.866.20.1.20.50.1.21.1.11
The value of this object indicates the default throughput class in transmit direction (equipment to remote peer). The default value is 4800 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclX25CfaNegDefInThroughputClass 2.1.866.20.1.20.50.1.21.1.12
The value of this object indicates the default throughput class in receive direction (remote peer to equipment). The default value is 4800 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclX25CfaNegMaxOutThroughputClass 2.1.866.20.1.20.50.1.21.1.13
The value of this object indicates the maximum throughput class in transmit direction (equipment to remote peer). The default value is 4800 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclX25CfaNegMaxInThroughputClass 2.1.866.20.1.20.50.1.21.1.14
The value of this object indicates the maximum throughput class in receive direction (equipment to remote peer). The default value is 4800 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclX25CfaNegPacketSize 2.1.866.20.1.20.50.1.21.1.20
The value of this object indicates whether the subscriber connected to the link has subscribed to packet size negociation facility or not. The authorized values are 'clear' (not subscriber) or 'subscribe'. The default value is 'subscribe'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), subscribe(2)  

fclX25CfaNegDefOutPacketSize 2.1.866.20.1.20.50.1.21.1.21
The value of this object indicates the default packet size in transmit direction (equipment to remote peer). The default value is 128 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfaNegDefInPacketSize 2.1.866.20.1.20.50.1.21.1.22
The value of this object indicates the default packet size in receive direction (remote peer to equipment). The default value is 128 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfaNegMaxOutPacketSize 2.1.866.20.1.20.50.1.21.1.23
The value of this object indicates the maximum packet size in transmit direction (equipment to remote peer). The default value is 256 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfaNegMaxInPacketSize 2.1.866.20.1.20.50.1.21.1.24
The value of this object indicates the maximum packet size in receive direction (remote peer to equipment). The default value is 256 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfaNegMinOutPacketSize 2.1.866.20.1.20.50.1.21.1.25
The value of this object indicates the minimum packet size in transmit direction (equipment to remote peer). The default value is 32 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfaNegMinInPacketSize 2.1.866.20.1.20.50.1.21.1.26
The value of this object indicates the minimum packet size in receive direction (remote peer to equipment). The default value is 32 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfaNegWindowSize 2.1.866.20.1.20.50.1.21.1.30
The value of this object indicates whether the subscriber connected to the link has subscribed to the negociation of the transmit window size facility or not. The authorized values are 'clear' (not subscriber) or 'subscribe'. The default value is 'subscribe'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), subscribe(2)  

fclX25CfaNegDefOutWindowSize 2.1.866.20.1.20.50.1.21.1.31
The value of this object indicates the default window size in transmit direction (equipment to remote peer). The authorized values are '1..7'. The default value is '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclX25CfaNegDefInWindowSize 2.1.866.20.1.20.50.1.21.1.32
The value of this object indicates the default window size in receive direction (remote peer to equipment). The authorized values are '1..7'. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclX25CfaNegMaxOutWindowSize 2.1.866.20.1.20.50.1.21.1.33
The value of this object indicates the maximum window size in transmit direction (equipment to remote peer). The authorized values are '1..7'. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclX25CfaNegMaxInWindowSize 2.1.866.20.1.20.50.1.21.1.34
The value of this object indicates the maximum window size in receive direction (remote peer to equipment). The authorized values are '1..7'. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclX25CfaSignallingTable 2.1.866.20.1.20.50.1.30
This table contains the signalling level parameters of X25 access configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfaSignallingEntry

fclX25CfaSignallingEntry 2.1.866.20.1.20.50.1.30.1
An entry of fclX25CfaSignallingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfaSignallingEntry  

fclX25CfaSigConfigId 2.1.866.20.1.20.50.1.30.1.1
The value of this object identifies one and only one X25 access configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfaSigType 2.1.866.20.1.20.50.1.30.1.2
The value of this object defines the signalling processing behaviour over the connected line. The authorized values are 'x25Network', 'x25Subscriber', 'x75'. The default value is 'x25Subscriber'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER x25Network(1), x25Subscriber(2), x75(3)  

fclX25CfaSigPacketAddressCount 2.1.866.20.1.20.50.1.30.1.3
The value of this object is the number of addresses in call request packets sent or received. The authorized values are '1..2'. The '1' value indicates that one of two addressing fields (calling address for packets from subscriber, called address for packets to subscriber) contains only the suffix (after DNIC ZO AB). The '2' value indicates that both addressing fields of each of the two types of call request packet (calling, called) contain the complete addresses. If fclX25CfaSigType is set to 'x25Network', the value of this object must be '2'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2  

fclX25CfaSigSubAddressTransmission 2.1.866.20.1.20.50.1.30.1.4
The value of this object indicates whether the sub-address of the called address field of the call request packet received on a PDNL (Public Data Network Link) is retransmitted on the outgoing line or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfaSigPdnIndicator 2.1.866.20.1.20.50.1.30.1.5
The value of this object specifies the behaviour of the equipment with respect to a PDNL (Public Data Network Link). The authorized values are : off : it is not a PDNL, pdnWithoutAddressTransmission : for a PDNL with address transport, pdnWithAddressTransmission : for a PDNL with address packing, dedicatedLaPoste : for Muse network, dedicatedTranspac : for Transpac network. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), pdnWithoutAddressTransmission(2), pdnWithAddressTransmission(5), dedicatedLaPoste(3), dedicatedTranspac(4)  

fclX25CfaSigConversionAimedPoint 2.1.866.20.1.20.50.1.30.1.10
The value of this object indicates whether the 'aimed point' address conversion is enabled or not. This conversion consists in making the routing process work not with the called address from the call packet but with a substituted address according to the address conversion table (see fcwAddrConvIncomingCallTable). Therefore this reduces the number of entries of the routing tables if several called addresses are converted to same 'aimed point' address. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfaSigConversionIncomingCall 2.1.866.20.1.20.50.1.30.1.11
The value of this object indicates which address field are converted on an incoming call. The authorized values are : off : no address field conversion, callingAddress : conversion of the calling address field according to the contains of fcwAddrConvIncomingCallTable, calledAddress : conversion of the called address field according to the contains of fcwAddrConvIncomingCallTable, callingAddressAndCalledAddress : conversion of the calling and called address fields according to the contains of fcwAddrConvIncomingCallTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fclX25CfaSigConversionOutgoingCall 2.1.866.20.1.20.50.1.30.1.12
The value of this object indicates which address field are converted on an outgoing call. The authorized values are : off : no address field conversion, callingAddress : conversion of the calling address field according to the contains of fcwAddrConvOutgoingCallTable, calledAddress : conversion of the called address field according to the contains of fcwAddrConvOutgoingCallTable, callingAddressAndCalledAddress : conversion of the calling and called address fields according to the contains of fcwAddrConvOutgoingCallTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fclX25CfaSigConversionAddressCheck 2.1.866.20.1.20.50.1.30.1.13
The value of this object indicates the behaviour of the equipment when a requested address conversion can not be made because the address is not found in the address conversion tables (fcwAddrConvIncomingCallTable or fcwAddrConvOutgoingCallTable). In this case the call will be cleared when 'checking' is enabled. The authorized values are : off : no checking, onIncomingCall : checking on incoming calls, onOutgoingCall : checking on outgoing calls, onIcomingCallAndOutgoingCall : checking on incoming and outgoing calls. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(4)  

fclX25CfaSigConvMultiCalledAddrInCall 2.1.866.20.1.20.50.1.30.1.14
Numero d'identification pour conversion d'adresse d'appele multi-criteres en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fclX25CfaSigConvMultiCallingAddrInCall 2.1.866.20.1.20.50.1.30.1.15
Numero d'identification pour conversion d'adresse d'appelant multi-criteres en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fclX25CfaSigConvMultiCalledAddrOutCall 2.1.866.20.1.20.50.1.30.1.16
Numero d'identification pour conversion d'adresse d'appele multi-criteres en sortie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fclX25CfaSigConvMultiCallingAddrOutCall 2.1.866.20.1.20.50.1.30.1.17
Numero d'identification pour conversion d'adresse d'appelant multi-criteres en sortie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fclX25CfaSigOutPacketCauseField 2.1.866.20.1.20.50.1.30.1.20
The value of this object describes which operation the equipment makes on the cause field of reset, clear, and restart request and indication outgoing packets. The authorized values are : noModify : no operation, setToZero : the cause field is set to 0 (meaning 'DTE originated'). The default value is 'noModify'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noModify(1), setToZero(2)  

fclX25CfaSigInPacketCauseField 2.1.866.20.1.20.50.1.30.1.21
The value of this object describes which operation the equipment makes on the cause field of reset, clear, and restart request and indication incoming packets. The authorized values are : noModify : no operation, setToZero : the cause field is set to 'DTE originated'. setToZeroIfLowerThan128 : the cause field is set to 'DTE originated' only if the bit 8 is 0 (i.e. if the bits 7 to 1 are those included by the remote DTE). modify : if the cause field is 'Invalid facility request' or 'Local procedure error' then it is changed to 'Network congestion' else no operation. The default value is 'noModify'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noModify(1), setToZero(2), setToZeroIfLowerThan128(3), modify(4)  

fclX25CfaSigT11CallResponseTimer 2.1.866.20.1.20.50.1.30.1.22
The value of this object is the maximum time (in seconds) the equipment will wait for a response to a call request packet sent on the link. A clear packet is sent if there is no response after this time. The authorized values are '10..2500' by step of 10. The default value is '200'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fclX25CfaSigCallAcceptedFormat 2.1.866.20.1.20.50.1.30.1.25
The value of this object defines the format of an outgoing call connected packet. The authorized values are : noFacilitiesNoAddresses : no facility length and facility fields, calling and called DTE address lengths set to 0, facilitiesNoAddresses : facility length and facility fields, calling and called DTE address lengths set to 0, facilitiesNoCheckedAdresses : facility length and facility fields, calling and called DTE address lengths different from 0, addresses are not checked (???), facilitiesCheckedAddresses : facility length and facility fields, calling and called DTE address lengths different from 0, addresses are checked (???), The default value is 'noFacilitiesNoAddresses'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noFacilitiesNoAddresses(3), facilitiesNoAddresses(2), facilitiesNotCheckedAddresses(4), facilitiesCheckedAddresses(1)  

fclX25CfaSigClearFormat 2.1.866.20.1.20.50.1.30.1.26
The value of this object defines the format of an outgoing call connected packet. The authorized values are : noFacilitiesNoAddresses : no facility length and facility fields, calling and called DTE address lengths set to 0, facilitiesNoAddresses : facility length and facility fields, calling and called DTE address lengths set to 0, facilitiesNoCheckedAdresses : facility length and facility fields, calling and called DTE address lengths different from 0, addresses are not checked (???), facilitiesCheckedAddresses : facility length and facility fields, calling and called DTE address lengths different from 0, addresses are checked (???), The default value is 'noFacilitiesNoAddresses'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noFacilitiesNoAddresses(3), facilitiesNoAddresses(2), facilitiesNotCheckedAddresses(4), facilitiesCheckedAddresses(1)  

fclX25CfaServiceTable 2.1.866.20.1.20.50.1.40
This table contains the services level parameters of X25 access configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfaServiceEntry

fclX25CfaServiceEntry 2.1.866.20.1.20.50.1.40.1
An entry of fclX25CfaServiceTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfaServiceEntry  

fclX25CfaSerConfigId 2.1.866.20.1.20.50.1.40.1.1
The value of this object identifies one and only one X25 access configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfaSerReliableVc 2.1.866.20.1.20.50.1.40.1.2
The value of this object is used to enable the Reliable Virtual Circuit service. The authorized values are : off : no RVC, the VCs are considered as normal VCs, no particular processing, clear : RVCs are not allowed for the subscriber, each attempt to establish a RVC provokes a clear of the connection, subscribe : all calls transmitted by the subscriber establish RVCs, it is also possible to receive calls with RVC option, check : for a link to a subscriber : when a call with RVC option is received, a RVC is established for a link to a network : the RVC option is ignored when it is present in a call sent by a local subscriber, the connection is cleared when the RVC option is present in a call sent by the network. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(3), subscribe(2), check(4)  

fclX25CfaSerCharging 2.1.866.20.1.20.50.1.40.1.3
The value of this object is used to enable the charging service. The authorized values are : off : no charging, overall : charging (a charging ticket is made of informations from all the lines of the equipment), detailed : charging (a charging ticket is made of informations from one virtual circuit), The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), overall(2), detailed(3)  

fclX25CfaSerX29Reselection 2.1.866.20.1.20.50.1.40.1.4
The value of this object indicates whether the subscriber connected to the link has subscribed to X29 reselection or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  


fclX25CfaSerStatLoadAndTraffic 2.1.866.20.1.20.50.1.40.1.10
The value of this object indicates whether, for this link, the load and traffic informations recording of the statistics management function is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfaSerStatSignalling 2.1.866.20.1.20.50.1.40.1.11
The value of this object indicates whether, for this link, the signalling informations recording of the statistics management function is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfaSerStatTotalizer 2.1.866.20.1.20.50.1.40.1.12
The value of this object indicates whether, for this link, the frames counting informations recording of the statistics management function is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfaSerStatCompression 2.1.866.20.1.20.50.1.40.1.13
The value of this object indicates whether, for this link, the compression informations recording of the statistics management function is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfaSerCompression 2.1.866.20.1.20.50.1.40.1.20
The value of this object indicates the compression enabling for each direction. The authorized values are : off : no compression, networkToSubscriber : compression of the flow from the remote peer to the equipment, subscriberToNetwork : compression of the flow from the equipment to the remote peer, bothway : compression of the two flows from and to the equipment. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), networkToSubscriber(2), subscriberToNetwork(3), bothway(4)  

fclX25CfaSerCompressNegotiation 2.1.866.20.1.20.50.1.40.1.21
The value of this object indicates whether the compression facility is negociated or not and, if negociated, the optional/obligatory status. The authorized values are : off' :no negociation, onOptionalCompression : negociation but compression is optional, onMandatoryCompression : negociation and compression is mandatory. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onOptionalCompression(2), onMandatoryCompression(3)  

fclX25CfaSerCompressScrambling 2.1.866.20.1.20.50.1.40.1.22
The value of this object indicates, when the compression is active, whether the scrambling is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfaSerCompressMultiPacketsTimer 2.1.866.20.1.20.50.1.40.1.23
The value of this object defines the maximum waiting time, in milliseconds by steps of 100 milliseconds , which, if there is not another packet to compress, the packet of compressed packets is sent beyond (this permits to reduce the number of packets transmitted to the remote peer). The authorized values are '0..1500'. '0' means no packets grouping (i. e. : each packet is individually compressed and sent). The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

fclX25CfaSerCos 2.1.866.20.1.20.50.1.40.1.30
COS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1)  

fclX25CfaSerCir 2.1.866.20.1.20.50.1.40.1.31
Entrant CIR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 600..2048000  

fclX25CfaSerMinCir 2.1.866.20.1.20.50.1.40.1.32
Entrant CIR mini
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclX25CfaSerBe 2.1.866.20.1.20.50.1.40.1.33
Entrant BE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fclX25CfaPackingAddresses 2.1.866.20.1.20.50.1.50
OBJECT IDENTIFIER    

fclX25CfaPackOutSubAddressCheck 2.1.866.20.1.20.50.1.50.1
The value of this object indicates whether the packing mechanism (see fclX25CfaPackingTable) is enabled for the outgoing call packets or not. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfaPackOutSubAddressSize 2.1.866.20.1.20.50.1.50.2
The value of this object defines the length of the substituted sub-address used by the packing mechanism (see fclX25CfaPackSubAddress). The authorized values are '1..4'. The default value is '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

fclX25CfaPackPdnCallingSubAddress 2.1.866.20.1.20.50.1.50.3
The value of this object indicates, when using the packing mechanism, whether the calling address is packed or is removed (i.e. there is no calling sub-address). The default value is 'remove'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pack(1), remove(2)  

fclX25CfaPackingTable 2.1.866.20.1.20.50.1.50.4
This table defines the association between the ZO SB part of the DNIC ZO SB address and the substituted sub-address (i.e. the 'packed ZO SB'). This substitution is enabled on a link when fclX25CfaSigPdnIndicator is set to 'pdnWithAddressTransmission'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfaPackingEntry

fclX25CfaPackingEntry 2.1.866.20.1.20.50.1.50.4.1
An entry of fclX25CfaPackingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfaPackingEntry  

fclX25CfaPackPrivateZoSb 2.1.866.20.1.20.50.1.50.4.1.1
The value of this object is the ZO SB part of the DNIC ZO SB address which is replaced by the sub-address defined in fclX25CfaPackSubAddress. The value may contain up to 4 digits (digits 0..9). The value must be completed with 'F' digits for a total of 4 digits. The equipment configurator does not need final completion. The default value is 'FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

fclX25CfaPackStatus 2.1.866.20.1.20.50.1.50.4.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25CfaPackSubAddress 2.1.866.20.1.20.50.1.50.4.1.3
The value of this object is the substituted sub-address (i.e. the 'packed ZO SB') which replaces the ZO SB part of the DNIC ZO SB address defined in fclX25CfaPackPrivateZoSb. The value may contain up to 'fclX25CfaPackOutSubAddressSize' digits (digits 0..9). The value must be completed with 'F' digits for a total of 4 digits. The equipment configurator does not need final completion. The default value is 'FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

fclX25CfaClosedUserGroupTable 2.1.866.20.1.20.50.1.51
This table defines the Closed User Groups to which belong the subscribers. This table is used on a link when fclX25CfaFacClosedUserGroup is set to 'subscribe' or 'subscribeAndRemove'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfaClosedUserGroupEntry

fclX25CfaClosedUserGroupEntry 2.1.866.20.1.20.50.1.51.1
An entry of fclX25CfaClosedUserGroupTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfaClosedUserGroupEntry  

fclX25CfaCugLogPortId 2.1.866.20.1.20.50.1.51.1.1
The value of this object identifies one and only one access logical port. There may up to 28 CUG for only one logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fclX25CfaCugClosedUserGroupId 2.1.866.20.1.20.50.1.51.1.2
This value defines one CUG associated to the logical port defined in fclX25CfaCugLogPortId. The possible values are : '0..99. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

fclX25CfaCugStatus 2.1.866.20.1.20.50.1.51.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25CfaCugChecking 2.1.866.20.1.20.50.1.51.1.4
The value of this object defines on which call the equipment checks this CUG. The default values is 'onIncomingCallAndOutgoingCall'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(1)  

fclX25CfaCugClosedUserGroupExt 2.1.866.20.1.20.50.1.51.1.5
GFU externe
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

fclX25ConfigInterNode 2.1.866.20.1.20.50.10
OBJECT IDENTIFIER    

fclX25ConfigInterNodeTable 2.1.866.20.1.20.50.10.1
This table contains the X25 inter-node configurations used by X25 inter-node links.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25ConfigInterNodeEntry

fclX25ConfigInterNodeEntry 2.1.866.20.1.20.50.10.1.1
An entry of fclX25ConfigInterNodeTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25ConfigInterNodeEntry  

fclX25CfnConfigId 2.1.866.20.1.20.50.10.1.1.1
The value of this object identifies one and only one X25 inter-node configuration. This configuration may be referenced by fclX25InBRemX25ConfigId, fclX25PstnX25InterNodeConfigId, fclX25SlpX25InterNodeConfigId, fclX25SlpIsdnRemX25InterNodeConfigId, fclX25SlpPstnBackX25InterNodeConfigId, fclX25MlpX25InterNodeConfigId or fclFrPvcX25InterNodeConfigId. The possible values are : '0..199. If it is unused, the value of this parameter is '255'. The X25 inter-node configuration parameters are described in : fclX25CfnaDataLinkNetworkTable : data link and network levels, fclX25CfnNegotiatedFacilityTable : facility level, fclX25CfnSignallingTable : signalling level, fclX25CfnServiceTable : services level. When creating a new configuration each parameter takes its default value. Setting a profile allows the user to fill all the parameters with values pre-defined in this profile but each one may also be individually modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfnStatus 2.1.866.20.1.20.50.10.1.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fclX25CfnDescription 2.1.866.20.1.20.50.10.1.1.3
The value of this object stores a text description of the X25 inter-node configuration elaborated by the user. This description may contains from 0 to 32 characters. The default value is 'DTE inter-node'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

fclX25CfnProfileId 2.1.866.20.1.20.50.10.1.1.4
The value of this object is the profile number used to automatically valorize all the X25 parameters in an entry of the four tables which composes X25 inter-node configurations (see fclX25CfnConfigId). The possible values are : 04 DTE inter-node, 05 DCE inter-node, 20 DTE PSTN back-up auto modem, 21 DCE PSTN back-up auto modem, 24 Inter-node (TRANSPAC), 24 Inter-node (TRANSPAC), 40 DTE PSTN back-up V.25bis modem, 1 DCE PSTN back-up V.25bis modem, 74 DTE inter-node X.75 physical, 75 DCE inter-node X.75 physical, 86 DTE FR network (p transac), 87 DCE FR network (p transac), 88 DTE FR Network (no priority), 89 DCE FR Network (no priority), If it is unused, the value of this parameter is '255'. The default value is '4' (meaning that default values of X25 parameters are those pre-defined in profile number 04).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfnModificationCount 2.1.866.20.1.20.50.10.1.1.5
The value of this object indicates how many X25 parameters have not the value defined in the profile specified by fclX25CfnProfileId (i.e how many individual modifications).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fclX25CfnDataLinkNetworkTable 2.1.866.20.1.20.50.10.10
This table contains the data link and network levels parameters of X25 inter-node configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfnDataLinkNetworkEntry

fclX25CfnDataLinkNetworkEntry 2.1.866.20.1.20.50.10.10.1
An entry of fclX25CfnDataLinkNetworkTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfnDataLinkNetworkEntry  

fclX25CfnDlnConfigId 2.1.866.20.1.20.50.10.10.1.1
The value of this object identifies one and only one X25 inter-node configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfnDlnStationType 2.1.866.20.1.20.50.10.10.1.2
The value of this object defines the type of the interface at the data link layer (and not at the physical layer which is defined in fcfLineType). The equipment can acts as a DTE (Data Terminal Equipment) or as a DCE (Data Circuit-terminating Equipment). The default value is 'dce'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2)  

fclX25CfnDlnN2RetryCount 2.1.866.20.1.20.50.10.10.1.5
The value of this object indicates the maximum number (N2) of attempts made by the equipment to complete the successfull transmission of a frame. The authorized values are '2..250'. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..250  

fclX25CfnDlnT1AcknowledgeTimer 2.1.866.20.1.20.50.10.10.1.6
The value of this object indicates the period (T1), in milliseconds, at the end of which retransmission of a frame may be initiated. The authorized values are '200..25000'. The default value is '800'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 200..25000  

fclX25CfnDlnT2AcknowledgeDelayTimer 2.1.866.20.1.20.50.10.10.1.7
The value of this object indicates the amount of time available (T2), in milliseconds, before the acknowledging frame must be initiated. This parameter must be smaller than T1. The authorized values are '100..12700'. The default value is '400'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..12700  

fclX25CfnDlnKWindowSize 2.1.866.20.1.20.50.10.10.1.8
The value of this object indicates the maximum number (K) of sequentially numbered I frames that the equipment may have outstanding (i.e.. unacknowledged) at any given time. The authorized values are '1..127'. The default value is '7'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fclX25CfnDlnEachPacketAcknowledgement 2.1.866.20.1.20.50.10.10.1.9
The value of this object indicates whether each frame is acknowledged or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfnDlnLowestIncomingChannel 2.1.866.20.1.20.50.10.10.1.10
The value of this object is the Lowest Incoming one-way logical Channel (LIC).The authorized values are '0..4095'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

fclX25CfnDlnIncomingChannelCount 2.1.866.20.1.20.50.10.10.1.11
The value of this object is the Number of Incoming one-way logical Channels (NIC). So the Highest Incoming one-way logical Channel (HIC) is : HIC = LIC + NIC - 1. The authorized values are '0..4096'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4096  

fclX25CfnDlnLowestTwoWayChannel 2.1.866.20.1.20.50.10.10.1.15
The value of this object is the Lowest Two-way logical Channel (LTC). The authorized values are '0..4095'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

fclX25CfnDlnTwoWayChannelCount 2.1.866.20.1.20.50.10.10.1.16
The value of this object is the Number of Two-way logical Channels. So the Highest Two-way logical Channel (HTC) is : HTC = LTC + NTC - 1. The authorized values are '0..4096'. The default value is '20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4096  

fclX25CfnDlnLowestOutgoingChannel 2.1.866.20.1.20.50.10.10.1.17
The value of this object is the Lowest Outgoing one-way logical Channel (LOC). The authorized values are '0..4095'. The default value is '20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

fclX25CfnDlnOutgoingChannelCount 2.1.866.20.1.20.50.10.10.1.18
The value of this object is the Number of Outgoing one-way logical Channels (NOC). So the Highest Outgoing one-way logical Channel (HOC) is : HOC = LOC + NOC - 1. The authorized values are '0..4096'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4096  

fclX25CfnDlnOutgoingChannelNumbering 2.1.866.20.1.20.50.10.10.1.19
The value of this object indicates whether the equipment searches for a logical channel from the lowest one to the highest one (incremental order) or from the highest one to the lowest one (decremental order). The default value is 'decremental'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER decremental(1), incremental(2)  

fclX25CfnDlnDBitModification 2.1.866.20.1.20.50.10.10.1.30
The value of this object indicates how the equipment manages the D bit (Delivery Confirmation Bit). When it receives a call from a DTE wishing to receive an end-to-end acknowledgement of delivery the equipment may : ignore this D bit procedure ('off' value), ??? indicate clearing ('clear' value), ??? ('on' value), The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(2), on(3)  

fclX25CfnNegotiatedFacilityTable 2.1.866.20.1.20.50.10.11
This table contains the facility level parameters of X25 inter-node configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfnNegotiatedFacilityEntry

fclX25CfnNegotiatedFacilityEntry 2.1.866.20.1.20.50.10.11.1
An entry of fclX25CfnNegotiatedFacilityTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfnNegotiatedFacilityEntry  

fclX25CfnNegConfigId 2.1.866.20.1.20.50.10.11.1.1
The value of this object identifies one and only one X25 inter-node configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfnNegOutputFastSelect 2.1.866.20.1.20.50.10.11.1.2
The value of this object specifies the behaviour of the equipment with respect to the fast select facility in outgoing call. The authorized values are 'noCheck' (no checking), 'clear' (clearing), 'subscribe'. The default value is 'noCheck'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(3), clear(1), subscribe(2)  

fclX25CfnNegInputFastSelect 2.1.866.20.1.20.50.10.11.1.3
The value of this object is the maximum size of the call user data field in a received call request packet not containing the fast select facility. The authorized values are 'subscribe' (up to 16 bytes) or 'longUserData' (up to 128 bytes). The default value is 'subscribe'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER subscribe(2), longUserData(4)  

fclX25CfnNegThroughputClass 2.1.866.20.1.20.50.10.11.1.10
The value of this object indicates whether the subscriber connected to the link has subscribed to throughput class negociation facility or not. The authorized values are 'clear' (not subscriber) or 'subscribe'. The default value is 'subscribe'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), subscribe(2)  

fclX25CfnNegDefOutThroughputClass 2.1.866.20.1.20.50.10.11.1.11
The value of this object indicates the default throughput class in transmit direction (equipment to remote peer). The default value is 9600 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclX25CfnNegDefInThroughputClass 2.1.866.20.1.20.50.10.11.1.12
The value of this object indicates the default throughput class in receive direction (remote peer to equipment). The default value is 9600 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclX25CfnNegMaxOutThroughputClass 2.1.866.20.1.20.50.10.11.1.13
The value of this object indicates the maximum throughput class in transmit direction (equipment to remote peer). The default value is 9600 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclX25CfnNegMaxInThroughputClass 2.1.866.20.1.20.50.10.11.1.14
The value of this object indicates the maximum throughput class in receive direction (equipment to remote peer). The default value is 9600 bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t75(3), t150(4), t300(5), t600(6), t1200(7), t2400(8), t4800(9), t9600(10), t19200(11), t48000(12), t64000(13), t128000(14), t192000(15)  

fclX25CfnNegPacketSize 2.1.866.20.1.20.50.10.11.1.20
The value of this object indicates whether the subscriber connected to the link has subscribed to packet size negociation facility or not. The authorized values are 'clear' (not subscriber) or 'subscribe'. The default value is 'subscribe'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), subscribe(2)  

fclX25CfnNegDefOutPacketSize 2.1.866.20.1.20.50.10.11.1.21
The value of this object indicates the default packet size in transmit direction (equipment to remote peer). The default value is 128 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfnNegDefInPacketSize 2.1.866.20.1.20.50.10.11.1.22
The value of this object indicates the default packet size in receive direction (remote peer to equipment). The default value is 128 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfnNegMaxOutPacketSize 2.1.866.20.1.20.50.10.11.1.23
The value of this object indicates the maximum packet size in transmit direction (equipment to remote peer). The default value is 256 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfnNegMaxInPacketSize 2.1.866.20.1.20.50.10.11.1.24
The value of this object indicates the maximum packet size in receive direction (remote peer to equipment). The default value is 256 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfnNegMinOutPacketSize 2.1.866.20.1.20.50.10.11.1.25
The value of this object indicates the minimum packet size in transmit direction (equipment to remote peer). The default value is 16 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfnNegMinInPacketSize 2.1.866.20.1.20.50.10.11.1.26
The value of this object indicates the minimum packet size in receive direction (remote peer to equipment). The default value is 16 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfnNegWindowSize 2.1.866.20.1.20.50.10.11.1.30
The value of this object indicates whether the subscriber connected to the link has subscribed to the negociation of the transmit window size facility or not. The authorized values are 'clear' (not subscriber) or 'subscribe'. The default value is 'subscribe'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), subscribe(2)  

fclX25CfnNegDefOutWindowSize 2.1.866.20.1.20.50.10.11.1.31
The value of this object indicates the default window size in transmit direction (equipment to remote peer). The authorized values are '1..7'. The default value is '3'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclX25CfnNegDefInWindowSize 2.1.866.20.1.20.50.10.11.1.32
The value of this object indicates the default window size in receive direction (remote peer to equipment). The authorized values are '1..7'. The default value is '3'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclX25CfnNegMaxOutWindowSize 2.1.866.20.1.20.50.10.11.1.33
The value of this object indicates the maximum window size in transmit direction (equipment to remote peer). The authorized values are '1..7'. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclX25CfnNegMaxInWindowSize 2.1.866.20.1.20.50.10.11.1.34
The value of this object indicates the maximum window size in receive direction (remote peer to equipment). The authorized values are '1..7'. The default value is '4'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fclX25CfnSignallingTable 2.1.866.20.1.20.50.10.30
This table contains the signalling level parameters of X25 inter-node configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfnSignallingEntry

fclX25CfnSignallingEntry 2.1.866.20.1.20.50.10.30.1
An entry of fclX25CfnSignallingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfnSignallingEntry  

fclX25CfnSigConfigId 2.1.866.20.1.20.50.10.30.1.1
The value of this object identifies one and only one X25 inter-node configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfnSigSubAddressTransmission 2.1.866.20.1.20.50.10.30.1.4
The value of this object indicates whether the sub-address of the called address field of the call request packet received on a PDNL (Public Data Network Link) is retransmitted on the outgoing line or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfnSigConversionAimedPoint 2.1.866.20.1.20.50.10.30.1.10
The value of this object indicates whether the 'aimed point' address conversion is enabled or not. This conversion consists in making the routing process work not with the called address from the call packet but with a substituted address according to the address conversion table (see fcwAddrConvIncomingCallTable). Therefore this reduces the number of entries of the routing tables if several called addresses are converted to same 'aimed point' address. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfnSigConversionIncomingCall 2.1.866.20.1.20.50.10.30.1.11
The value of this object indicates which address field are converted on an incoming call. The authorized values are : off : no address field conversion, callingAddress : conversion of the calling address field according to the contains of fcwAddrConvIncomingCallTable, calledAddress : conversion of the called address field according to the contains of fcwAddrConvIncomingCallTable, callingAddressAndCalledAddress : conversion of the calling and called address fields according to the contains of fcwAddrConvIncomingCallTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fclX25CfnSigConversionOutgoingCall 2.1.866.20.1.20.50.10.30.1.12
The value of this object indicates which address field are converted on an outgoing call. The authorized values are : off : no address field conversion, callingAddress : conversion of the calling address field according to the contains of fcwAddrConvOutgoingCallTable, calledAddress : conversion of the called address field according to the contains of fcwAddrConvOutgoingCallTable, callingAddressAndCalledAddress : conversion of the calling and called address fields according to the contains of fcwAddrConvOutgoingCallTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fclX25CfnSigConversionAddressCheck 2.1.866.20.1.20.50.10.30.1.13
The value of this object indicates the behaviour of the equipment when a requested address conversion can not be made because the address is not found in the address conversion tables (fcwAddrConvIncomingCallTable or fcwAddrConvOutgoingCallTable). In this case the call will be cleared when 'checking' is enabled. The authorized values are : off : no checking, onIncomingCall : checking on incoming calls, onOutgoingCall : checking on outgoing calls, onIcomingCallAndOutgoingCall : checking on incoming and outgoing calls. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(4)  

fclX25CfnSigConvMultiCalledAddrInCall 2.1.866.20.1.20.50.10.30.1.14
Numero d'identification pour conversion d'adresse d'appele multi-criteres en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fclX25CfnSigConvMultiCallingAddrInCall 2.1.866.20.1.20.50.10.30.1.15
Numero d'identification pour conversion d'adresse d'appelant multi-criteres en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fclX25CfnSigConvMultiCalledAddrOutCall 2.1.866.20.1.20.50.10.30.1.16
Numero d'identification pour conversion d'adresse d'appele multi-criteres en sortie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fclX25CfnSigConvMultiCallingAddrOutCall 2.1.866.20.1.20.50.10.30.1.17
Numero d'identification pour conversion d'adresse d'appelant multi-criteres en sortie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fclX25CfnSigT11CallResponseTimer 2.1.866.20.1.20.50.10.30.1.22
The value of this object is the maximum time (in seconds) the equipment will wait for a response to a call request packet sent on the link. A clear packet is sent if there is no response after this time. The authorized values are '10..2500' by step of 10. The default value is '200'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fclX25CfnSigCallAcceptedFormat 2.1.866.20.1.20.50.10.30.1.25
The value of this object defines the format of an outgoing call connected packet. The authorized values are : noFacilitiesNoAddresses : no facility length and facility fields, calling and called DTE address lengths set to 0, facilitiesNoAddresses : facility length and facility fields, calling and called DTE address lengths set to 0, facilitiesNoCheckedAdresses : facility length and facility fields, calling and called DTE address lengths different from 0, addresses are not checked (???), facilitiesCheckedAddresses : facility length and facility fields, calling and called DTE address lengths different from 0, addresses are checked (???), The default value is 'noFacilitiesNoAddresses'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noFacilitiesNoAddresses(3), facilitiesNoAddresses(2), facilitiesNotCheckedAddresses(4), facilitiesCheckedAddresses(1)  

fclX25CfnServiceTable 2.1.866.20.1.20.50.10.40
This table contains the services level parameters of X25 inter-node configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfnServiceEntry

fclX25CfnServiceEntry 2.1.866.20.1.20.50.10.40.1
An entry of fclX25CfnServiceTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfnServiceEntry  

fclX25CfnSerConfigId 2.1.866.20.1.20.50.10.40.1.1
The value of this object identifies one and only one X25 inter-node configuration. The possible values are : '0..199. If it is unused, the value of this parameter is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fclX25CfnSerReliableVc 2.1.866.20.1.20.50.10.40.1.2
The value of this object is used to enable the Reliable Virtual Circuit service. The authorized values are : off : no RVC, the VCs are considered as normal VCs, no particular processing, clear : RVCs are not allowed for the subscriber, each attempt to establish a RVC provokes a clear of the connection, subscribe : all calls transmitted by the subscriber establish RVCs, it is also possible to receive calls with RVC option, check : for a link to a subscriber : when a call with RVC option is received, a RVC is established for a link to a network : the RVC option is ignored when it is present in a call sent by a local subscriber, the connection is cleared when the RVC option is present in a call sent by the network. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(3), subscribe(2), check(4)  

fclX25CfnSerCharging 2.1.866.20.1.20.50.10.40.1.3
The value of this object is used to enable the charging service. The authorized values are : off : no charging, overall : charging (a charging ticket is made of informations from all the lines of the equipment), detailed : charging (a charging ticket is made of informations from one virtual circuit), The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), overall(2), detailed(3)  

fclX25CfnSerX29Reselection 2.1.866.20.1.20.50.10.40.1.4
The value of this object indicates whether the subscriber connected to the link has subscribed to X29 reselection or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  


fclX25CfnSerCallReturnTransmission 2.1.866.20.1.20.50.10.40.1.6
The value of this object indicates whether the 'call return' packet may be sent on this link or not. The 'call return' packet, sent to the previous equipment, makes this equipments search for another route to join the called DTE. The defaut value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(3)  

fclX25CfnSerStatLoadAndTraffic 2.1.866.20.1.20.50.10.40.1.10
The value of this object indicates whether, for this link, the load and traffic informations recording of the statistics management function is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfnSerStatSignalling 2.1.866.20.1.20.50.10.40.1.11
The value of this object indicates whether, for this link, the signalling informations recording of the statistics management function is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfnSerStatTotalizer 2.1.866.20.1.20.50.10.40.1.12
The value of this object indicates whether, for this link, the frames counting informations recording of the statistics management function is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfnSerStatCompression 2.1.866.20.1.20.50.10.40.1.13
The value of this object indicates whether, for this link, the compression informations recording of the statistics management function is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25ConfigMiscellaneous 2.1.866.20.1.20.50.30
OBJECT IDENTIFIER    

fclX25CfmDiagnosticCodeField 2.1.866.20.1.20.50.30.1
The value of this object indicates how the diagnostic field is encoded. The default value is 'privateCoding'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER privateCoding(2), publicCoding(1), x75Coding(3)  

fclX25CfmTransmitFlowControl 2.1.866.20.1.20.50.30.2
The value of this object indicates whether the flow control is made according to the standard or according to fclX25CfmTransmitFlowControlTable (this way is used by TRANSPAC). The default value is 'standard'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER standard(1), dedicatedTranspac(2)  

fclX25CfmAddress14DigitsTruncation 2.1.866.20.1.20.50.30.3
The value of this object indicates whether the addresses are truncated to 14 digits or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fclX25CfmTransmitFlowControlTable 2.1.866.20.1.20.50.30.20
This table defines non standard flow control. This table is used if fclX25CfmTransmitFlowControl is set to 'dedicatedTranspac'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FclX25CfmTransmitFlowControlEntry

fclX25CfmTransmitFlowControlEntry 2.1.866.20.1.20.50.30.20.1
An entry of fclX25CfmTransmitFlowControlTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FclX25CfmTransmitFlowControlEntry  

fclX25CfmFlowCtrlPacketSize 2.1.866.20.1.20.50.30.20.1.1
The value of this object defines a packet size.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER s16(4), s32(5), s64(6), s128(7), s256(8), s512(9), s1024(10), s2048(11), s4096(12), s8192(13)  

fclX25CfmFlowCtrlMaxWindowSize 2.1.866.20.1.20.50.30.20.1.2
The value of this object defines the maximum window size used for this packet size.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fcWanSwitch 2.1.866.20.1.25
OBJECT IDENTIFIER    

fcwDnicZoAddress 2.1.866.20.1.25.1
The value of this object is the address of the equipment. This address , with a DNIC ZO format as explained below, must have 6 digits (0..9). The default value is '900000'. Address format : Eight digits (0..9) of X121 format are used as the network address numbering plan. This numbering plan has a hierarchical structure : 4 digits define the Data Network Identifier Code (DNIC) : DNIC identifies the region to which belongs the equipment, 2 digits define the zone (ZO) : ZO identifies the equipment inside the region, 2 digits define the subscriber (SB) : SB identifies a subscriber of the equipment. Therefore each subscriber is completely identified by its address of the form DNIC ZO SB and each equipment by its address of the form DNIC ZO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

fcwMaxActiveCommunications 2.1.866.20.1.25.10
The value of this object defines the maximum number of the simultaneous active communications. The authorized values are '32..2048'. The default value is '512'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 256..4064  

fcwDataPacketsDiscardThreshold 2.1.866.20.1.25.20
The value of this object defines the busy memory threshold, in percentage of the total memory resources, beyond which the equipment discards the X25 data packets. The authorized values are '10..99'. The default value is '98'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..99  

fcwDataPacketsAcceptThreshold 2.1.866.20.1.25.21
The value of this object defines the busy memory threshold, in percentage of the total memory resources, under which the equipment does not discard any more the X25 data packets. The authorized values are '10..99'. The default value is '98'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..99  

fcwCallPacketsDiscardThreshold 2.1.866.20.1.25.22
The value of this object defines the busy memory threshold, in percentage of the total memory resources, beyond which the equipment discards the X25 call packets. The authorized values are '10..99'. The default value is '95'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..99  

fcwCallPacketsAcceptThreshold 2.1.866.20.1.25.23
The value of this object defines the busy memory threshold, in percentage of the total memory resources, under which the equipment does not discard any more the X25 call packets. The authorized values are '10..99'. The default value is '90'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..99  

fcwLocalCommunications 2.1.866.20.1.25.30
The value of this object defines whether the local communications (i.e. between two subscribers to this equipment) are authorized or not. For instance, these communications are denied when it is neccessary to re-route them to a billing equipment. The route used in this case is defined by fcwLocalIncomingCallsRouteId. The default value is 'permitted'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER denied(1), permitted(2)  

fcwLocalIncomingCallsRouteId 2.1.866.20.1.25.31
The value of this object defines the route used by the local incoming call packets when the local communications are forbidden (fcwLocalCommunications set to 'denied'). This route must exist in fcwRouteTable. The authorized values are '0..199'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fcwLoadAndTrafficSummingPeriod 2.1.866.20.1.25.40
The value of this object is the period, in seconds, during which load and traffic quantity is summed and used by the switch over or overflow mechanisms. The authorized values are '10..2500' by step of 10. The default value is '20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fcwLoadAndTrafficEventsTimer 2.1.866.20.1.25.41
The value of this object defines the time, in seconds, between two load and traffic event generations. These event are generated by the switch over or overflow mechanisms when a threshold is crossed. The authorized values are '10..2500' by step of 10. The default value is '20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fcwFrameRelay 2.1.866.20.1.25.45
OBJECT IDENTIFIER    

fcwFrDlcStatusChangeTrapEnabling 2.1.866.20.1.25.45.5
Emission du TRAP 'changement d'etat d'une terminaison PVC' defini en RFC1315
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcwFrAnnexeGInternalStacksMaxCount 2.1.866.20.1.25.45.6
Nb max d'instances FRI disponible
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2000  

fcwFrEndPointMaxCount 2.1.866.20.1.25.45.10
Nb max de terminaisons FR simultanees (SVC ou PVC)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..5000  

fcwFrFrameAcceptCpuThreshold 2.1.866.20.1.25.45.20
Seuil : CPU autorisee pour l'acceptation des trames
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fcwFrFrameAcceptMemoryThreshold 2.1.866.20.1.25.45.21
Seuil : Memoire autorisee pour l'acceptation des trames
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fcwFrDlcSetupAlarmThreshold 2.1.866.20.1.25.45.22
Seuil : A% seuil alarmique d'acceptation de connexions FR en terme de ressources
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fcwFrDlcSetupDiscardThreshold 2.1.866.20.1.25.45.23
R% Seuil de refus d'etablissement des DLC VBR-NRT (pourcentage des ressources : 100 = pas de surbooking)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..350  

fcwFrVoiceFrameSize 2.1.866.20.1.25.45.40
Longueur trames voix
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fcwFrVoiceMaxTransitDelay 2.1.866.20.1.25.45.41
Temps de transit maximum de bout en bout des communications de type voix en millisecondes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fcwFrCongestionCheckTimer 2.1.866.20.1.25.45.50
Tempo de surveillance de la congestion du reseau FR (milisecondes)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 200..4000  

fcwFrCongestionCount 2.1.866.20.1.25.45.51
Critere de decongestion du reseau FR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..255  

fcwFrCirTimer 2.1.866.20.1.25.45.52
Tempo echantillonage CIR (millisecondes)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 20..400  

fcwFrEventOutput 2.1.866.20.1.25.45.53
Filtrage des EVR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), oneOutOf16(3), oneOutOf64(4), oneOutOf256(5), all(2)  

fcwFrSlowingDownThreshold 2.1.866.20.1.25.45.54
S0 seuil de ralentissement du trafic sans positionner de bits de congestion (0 = pas de ralentissement)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fcwFrFecnBecnOfDeFramesThreshold 2.1.866.20.1.25.45.55
S1 seuil de positionnement des bits FECN BECN sur les trames DE (0 = calcule en fct de la vitesse de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fcwFrFecnBecnOfAllFramesThreshold 2.1.866.20.1.25.45.56
S2 seuil de positionnement des bits FECN BECN sur toutes les trames (0 = calcule en fct de la vitesse de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fcwFrDeFramesDiscardThreshold 2.1.866.20.1.25.45.57
S3 seuil de rejet des trames DE (0 = calcule en fct de la vitesse de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fcwFrAllFramesDiscardThreshold 2.1.866.20.1.25.45.58
S4 seuil de rejet de toutes les trames (0 = calcule en fct de la vitesse de la ligne)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

fcwAddressConversion 2.1.866.20.1.25.48
OBJECT IDENTIFIER    

fcwAddrConvIncomingCallTable 2.1.866.20.1.25.48.1
This table defines, for the incoming call packets, the association between an X121 address pattern to be converted and the substituted address pattern. This substitution is used on the logical ports when *ConversionAimedPoint is set to 'on', *ConversionIncomingCall is not set to 'off' or *ConversionAddressCheck is set to 'onIncomingCall' or 'onIncomingCallAndOutgoingCall'. Two digits have special meanings : The digit 'C' ('$' on the equipment configurator) when simultaneously used in the address pattern to be converted AND in the converted address pattern matches any single digit which will be reported in the converted address. Example : fcwConvInExternalAddr = 1234C6C8FFFFFFF fcwConvInConvertedAddr = 900010CCFFFFFFF 1234567890 is converted to 9000105790 The digit 'D' ('?' on the equipment configurator) when used in the address pattern to be converted matches any single digit which will not be present in the converted address. Example : fcwConvInExternalAddr = 1234DD78FFFFFFF fcwConvInConvertedAddr = 9000FFFFFFFFFFF 1234567890 is converted to 900090, 1234007890 is converted to 900090, 1234560090 is not converted.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwAddrConvIncomingCallEntry

fcwAddrConvIncomingCallEntry 2.1.866.20.1.25.48.1.1
An entry of fcwAddrConvIncomingCallTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwAddrConvIncomingCallEntry  

fcwConvInExternalAddr 2.1.866.20.1.25.48.1.1.1
The value of this object identifies one and only one external address pattern to be converted. The value may contain up to 15 digits (digits 0..9, special digits C and D). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator). The conversion mechanism is explained in the description of this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcwConvInStatus 2.1.866.20.1.25.48.1.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwConvInConvertedAddr 2.1.866.20.1.25.48.1.1.3
The value of this object defines the converted address pattern. The value may contain up to 15 digits (digits 0..9, special digit C). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator). The conversion mechanism is explained in the description of this table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcwConvInOrderNum 2.1.866.20.1.25.48.1.1.4
No ordre
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcwAddrConvOutgoingCallTable 2.1.866.20.1.25.48.2
This table defines, for the outgoing call packets, the association between an X121 address pattern to be converted and the substituted address pattern. This substitution is used on the logical ports when *ConversionOutgoingCall is not set to 'off' or *ConversionAddressCheck is set to 'onOutgoingCall' or 'onIncomingCallAndOutgoingCall'. Two digits have special meanings : The digit 'C' ('$' on the equipment configurator) when simultaneously used in the address pattern to be converted AND in the converted address pattern matches any single digit which will be reported in the converted address. Example : fcwConvOutExternalAddr = 1234C6C8FFFFFFF fcwConvOutConvertedAddr = 900010CCFFFFFFF 1234567890 is converted to 9000105790 The digit 'D' ('?' on the equipment configurator) when used in the address pattern to be converted matches any single digit which will not be present in the converted address. Example : fcwConvOutExternalAddr = 1234DD78FFFFFFF fcwConvOutConvertedAddr = 9000FFFFFFFFFFF 1234567890 is converted to 900090, 1234007890 is converted to 900090, 1234560090 is not converted.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwAddrConvOutgoingCallEntry

fcwAddrConvOutgoingCallEntry 2.1.866.20.1.25.48.2.1
An entry of fcwAddrConvOutgoingCallTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwAddrConvOutgoingCallEntry  

fcwConvOutExternalAddr 2.1.866.20.1.25.48.2.1.1
The value of this object identifies one and only one external address pattern to be converted. The value may contain up to 15 digits (digits 0..9, special digits C and D). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator). The conversion mechanism is explained in the description of this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcwConvOutStatus 2.1.866.20.1.25.48.2.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwConvOutConvertedAddr 2.1.866.20.1.25.48.2.1.3
The value of this object defines the converted address pattern. The value may contain up to 15 digits (digits 0..9, special digit C). The value must be completed with 'F' digits for a total of 16 digits. The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator). The conversion mechanism is explained in the description of this table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcwConvOutOrderNum 2.1.866.20.1.25.48.2.1.4
No ordre
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcwAddrConvMultiCriterionInCallTable 2.1.866.20.1.25.48.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwAddrConvMultiCriterionInCallEntry

fcwAddrConvMultiCriterionInCallEntry 2.1.866.20.1.25.48.3.1
An entry of fcwAddrConvMultiCriterionInCallTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwAddrConvMultiCriterionInCallEntry  

fcwConvMultiInConvID 2.1.866.20.1.25.48.3.1.1
Conversion ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcwConvMultiInExternalAddr 2.1.866.20.1.25.48.3.1.2
Prefixe adresse exterieur
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

fcwConvMultiInStatus 2.1.866.20.1.25.48.3.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwConvMultiInConvertedAddr 2.1.866.20.1.25.48.3.1.4
Prefixe converti
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

fcwConvMultiInOrderNum 2.1.866.20.1.25.48.3.1.5
No ordre
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcwAddrConvMultiCriterionOutCallTable 2.1.866.20.1.25.48.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwAddrConvMultiCriterionOutCallEntry

fcwAddrConvMultiCriterionOutCallEntry 2.1.866.20.1.25.48.4.1
An entry of fcwAddrConvMultiCriterionOutCallTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwAddrConvMultiCriterionOutCallEntry  

fcwConvMultiOutConvID 2.1.866.20.1.25.48.4.1.1
Conversion ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcwConvMultiOutExternalAddr 2.1.866.20.1.25.48.4.1.2
Prefixe adresse exterieur
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

fcwConvMultiOutStatus 2.1.866.20.1.25.48.4.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwConvMultiOutConvertedAddr 2.1.866.20.1.25.48.4.1.4
Prefixe converti
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

fcwConvMultiOutOrderNum 2.1.866.20.1.25.48.4.1.5
No ordre
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcwAddrConvCondOutgoingCallTable 2.1.866.20.1.25.48.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwAddrConvCondOutgoingCallEntry

fcwAddrConvCondOutgoingCallEntry 2.1.866.20.1.25.48.5.1
An entry of fcwAddrConvCondOutgoingCallTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwAddrConvCondOutgoingCallEntry  

fcwConvCondOutExternalAddr 2.1.866.20.1.25.48.5.1.1
The value of this object identifies one and only one external address pattern to be converted. The value may contain up to 12 digits (digits 0..9, special digits C and D). The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator). The conversion mechanism is explained in the description of fcwAddrConvOutgoingCallTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

fcwConvCondOutTryOn 2.1.866.20.1.25.48.5.1.2
The value of this object defines which kind of LP in the route table the entry is associated with : all : this conversion is for both primary LP with routing type normalClear1, and associated backup LP, normalClear1 : this conversion is only for primary LP with routing type normalClear1, backup : this conversion is only for backups of primary LP with routing type normalClear1, The default value is 'all'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normalClear1(1), backup(2), all(3)  

fcwConvCondOutStatus 2.1.866.20.1.25.48.5.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwConvCondOutConvertedAddr 2.1.866.20.1.25.48.5.1.4
The value of this object defines the converted address pattern. The value may contain up to 12 digits (digits 0..9, special digit C). The equipment configurator does not need final completion. The default value is 'FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator The conversion mechanism is explained in the description of fcwAddrConvOutgoingCallTable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

fcwRouteTable 2.1.866.20.1.25.50
This table defines the routes which may be used by the call packets according to the routing tables. One route is composed of one or more logical ports. Most of times each logical port has only one channel and it is not necessary to indicates the channel identifier.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwRouteEntry

fcwRouteEntry 2.1.866.20.1.25.50.1
An entry of fcwRouteTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwRouteEntry  

fcwRoutRouteId 2.1.866.20.1.25.50.1.1
The value of this object identifies one and only one route. One route may be composed of one or several logical ports. The possible values are : '0..199'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcwRoutLogPortId 2.1.866.20.1.25.50.1.2
The value of this object identifies one of the logical ports which compose the route defined by fcwRoutRouteId. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..181  

fcwRoutChannelId 2.1.866.20.1.25.50.1.3
The value of this object identifies one of the channels available on the logical port defined by fcwRoutLogPortId. Most of times each logical port has only one channel and it is not necessary to indicates this channel identifier. In some very particular cases a logical port may have several channels and the equipment is not able to choose the right one. So the channel identifier must be indicated. This happens, for instance, with a Frame Relay logical port which has several Permanent Virtual Circuit end points and when it is impossible to find which one must be used : the corresponding DLCI (Data Link Connection Identifier) must be indicated in fcwRoutChannelId. The possible values are : '0..1023'. If it is unused, the value of this parameter is '65535'. The default value is '65535'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

fcwRoutStatus 2.1.866.20.1.25.50.1.4
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwRoutType 2.1.866.20.1.25.50.1.5
The value of this object indicates how the equipment will try to use this logical port (or this couple [logical port, channel]) which composes this route. The following combinations are possible : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |Route|LP|Type| Routing description | |~~~~~|~~|~~~~|~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| | 1 | 1| n | -> on one LP | |~~~~~|~~|~~~~|~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| | 2 | 1| n | -> 1 : on one main LP | | 2 | 2| b1 | \ | | 2 | 3| b1 | > 2 : on three equal | | 2 | 4| b1 | / priority backup LPs | |~~~~~|~~|~~~~|~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| | 3 | 1| n | \ | | 3 | 2| n | | | | 3 | 3| n | > on five equal priority LPs | | 3 | 4| n | | | | 3 | 5| n | / | |~~~~~|~~|~~~~|~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| | 4 | 1| n | -> 1 : on one main LP | | 4 | 2| b1 | -> 2 : on one first backup LP | | 4 | 3| b2 | -> 3 : on one second backup LP | | 4 | 4| b3 | -> 4 : on one third backup LP | |~~~~~|~~|~~~~|~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| | 5 | 1| n | \ on three equal | | 5 | 2| n | > 1 : priority main LPs | | 5 | 3| n | / | | 5 | 4| b1 | -> 2 : on one backup LP | |~~~~~|~~|~~~~|~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| | 8 | 1| nM | each module of the equipment | | 8 | 2| b1 | considers its own LPs as having | | 8 |11| b2 | a higher priority than the | | 8 | 3| b3 | LPs of the other modules | | 8 |21| b4 | (see below) | | 8 |12| b5 | | |~~~~~|~~|~~~~|~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| | 9 | 1| nC | -> 1 : on one main LP | |~~~~~|~~|~~~~|~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| | 10 | 1| nC | -> 1 : on one main LP | | 10 | 2| b1 | -> 2 : on one first backup LP | | 10 | 3| b2 | -> 3 : on one second backup LP | | 10 | 4| b3 | -> 4 : on one third backup LP | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Types : n : normal, nM : normalPriorityModule, b1 : backup1, b2 : backup2, b3 : backup3, b4 : backup4, b5 : backup5, dynamic, backupDynamic, nC : normalClear1. Interpretation of the route 8 : In this example let us suppose that LP 1, 2 and 3 belongs to the module 0, 11 and 12 to the module 1, and 21 to the module 2. The route 8 becomes : on the module 0 : LP : 1 2 3 11 21 12 Type : n b1 b2 b3 b4 b5 on the module 1 : LP : 11 12 1 2 3 21 Type : n b1 b2 b3 b4 b5 on the module 2 : LP : 21 1 2 11 3 12 Type : n b1 b2 b3 b4 b5 Interpretation of the route 9 : there must be at least 1 valid entry with try on = normalClear1 (or all) in the Clear cause/diagnostic table. The address is converted according to that entry. Interpretation of the route 10 : there must be at least 1 valid entry with try on = normalClear1 and 1 with try on = backup (or 1 with all) in the Clear cause/diagnostic table. The address is converted according to that entry. The default value is 'normal'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), normalPriorityModule(2), backup1(3), backup2(4), backup3(5), backup4(6), backup5(7), dynamic(8), backupDynamic(9), normalClear1(10)  

fcwDnicRoutingTable 2.1.866.20.1.25.60
This table is the call packets routing table for the Data Network Identifier Code (DNIC) part of the X121 called address.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwDnicRoutingEntry

fcwDnicRoutingEntry 2.1.866.20.1.25.60.1
An entry of fcwDnicRoutingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwDnicRoutingEntry  

fcwDnicDataNetworkIdentifierCode 2.1.866.20.1.25.60.1.1
The value of this object is the Data Network Identifier Code (DNIC) part of the X121 called address from the call packet to be routed. This address , with a DNIC format as explained below, may contain up to 4 digits (0..9, B). The digit 'B' (character '*' on the equipment configurator) have special meaning : 'B' matches any address. When used it must be the only digit specified (with final completion as explained below). The associated route is used only if the equipment does not find another possibility in this table. There must be only one route for each specified address but partial addresses are accepted. Example : If route 1 is specified for DNIC '1234', route 2 for DNIC '12' and route 3 for DNIC 'B', call packets to DNIC 1234 are routed on the route 1, call packets to DNIC 12xx (xx different from 34) are routed on the route 2 and all others are routed on the route 3. The value must be completed with 'F' digits for a total of 4 digits. The equipment configurator does not need final completion. The default value is 'FF FF' meaning 'empty value' (blank value on the equipment configurator). Address format : Eight digits (0..9) of X121 format are used as the network address numbering plan. This numbering plan has a hierarchical structure : 4 digits define the Data Network Identifier Code (DNIC) : DNIC identifies the region to which belongs the equipment, 2 digits define the zone (ZO) : ZO identifies the equipment inside the region, 2 digits define the subscriber (SB) : SB identifies a subscriber of the equipment. Therefore each subscriber is completely identified by its address of the form DNIC ZO SB and each equipment by its address of the form DNIC ZO.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

fcwDnicRouteId 2.1.866.20.1.25.60.1.2
The value of this object defines the route associated to this address. This route must exist in fcwRouteTable. The authorized values are '0..199'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcwDnicStatus 2.1.866.20.1.25.60.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwZoRoutingTable 2.1.866.20.1.25.61
This table is the call packets routing table for the Zone (ZO) part of the X121 called address.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwZoRoutingEntry

fcwZoRoutingEntry 2.1.866.20.1.25.61.1
An entry of fcwZoRoutingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwZoRoutingEntry  

fcwZoZone 2.1.866.20.1.25.61.1.1
The value of this object is the Zone (ZO) part of the X121 called address from the call packet to be routed. This address , with a ZO format as explained below, must contains 2 digits (0..9, B). The digit 'B' (character '*' on the equipment configurator) have special meaning : 'B' matches any address. When used it must be the only digit specified (with final completion as explained below). The associated route is used only if the equipment does not find another possibility in this table. There must be only one route for each specified address. Example : If route 1 is specified for ZO '12', route 2 for ZO 'B', call packets to ZO 12 are routed on the route 1 and all others are routed on the route 2. The value must be completed with 'F' digits for a total of 2 digits (here only if the digit 'B' is used). The equipment configurator does not need final completion. The default value is 'FF' meaning 'empty value' (blank value on the equipment configurator). Address format : Eight digits (0..9) of X121 format are used as the network address numbering plan. This numbering plan has a hierarchical structure : 4 digits define the Data Network Identifier Code (DNIC) : DNIC identifies the region to which belongs the equipment, 2 digits define the zone (ZO) : ZO identifies the equipment inside the region, 2 digits define the subscriber (SB) : SB identifies a subscriber of the equipment. Therefore each subscriber is completely identified by its address of the form DNIC ZO SB and each equipment by its address of the form DNIC ZO.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcwZoRouteId 2.1.866.20.1.25.61.1.2
The value of this object defines the route associated to this address. This route must exist in fcwRouteTable. The authorized values are '0..199'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcwZoStatus 2.1.866.20.1.25.61.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwSbRoutingTable 2.1.866.20.1.25.62
This table is the call packets routing table for the Subscriber (SB) part of the X121 called address.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwSbRoutingEntry

fcwSbRoutingEntry 2.1.866.20.1.25.62.1
An entry of fcwSbRoutingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwSbRoutingEntry  

fcwSbSubscriberNumber 2.1.866.20.1.25.62.1.1
The value of this object is the Subscriber (SB) part of the X121 called address from the call packet to be routed. This address , with a SB format as explained below, must contains 2 digits (0..9, B). The digit 'B' (character '*' on the equipment configurator) have special meaning : 'B' matches any address. When used it must be the only digit specified (with final completion as explained below). The associated route is used only if the equipment does not find another possibility in this table. There must be only one route for each specified address. Example : If route 1 is specified for SB '12', route 2 for SB 'B', call packets to SB 12 are routed on the route 1 and all others are routed on the route 2. The value must be completed with 'F' digits for a total of 2 digits (here only if the digit 'B' is used). The equipment configurator does not need final completion. The default value is 'FF' meaning 'empty value' (blank value on the equipment configurator). Address format : Eight digits (0..9) of X121 format are used as the network address numbering plan. This numbering plan has a hierarchical structure : 4 digits define the Data Network Identifier Code (DNIC) : DNIC identifies the region to which belongs the equipment, 2 digits define the zone (ZO) : ZO identifies the equipment inside the region, 2 digits define the subscriber (SB) : SB identifies a subscriber of the equipment. Therefore each subscriber is completely identified by its address of the form DNIC ZO SB and each equipment by its address of the form DNIC ZO.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcwSbRouteId 2.1.866.20.1.25.62.1.2
The value of this object defines the route associated to this address. This route must exist in fcwRouteTable. The authorized values are '0..199'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcwSbStatus 2.1.866.20.1.25.62.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwServices 2.1.866.20.1.25.70
OBJECT IDENTIFIER    

fcwSerCompression 2.1.866.20.1.25.70.1
OBJECT IDENTIFIER    

fcwSCompModule0CompressedVcCount 2.1.866.20.1.25.70.1.1
The value of this object defines the maximum number of virtual circuits which may be simultaneously compressed by the module 0 of the equipment. The compression of virtual circuits may be enabled at the logical port level. The authorized values are '0..2048'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048  

fcwSCompModule1CompressedVcCount 2.1.866.20.1.25.70.1.2
The value of this object defines the maximum number of the virtual channels that may be simultaneously compressed by the module 0 of the equipment. The authorized values are '0..2048'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048  

fcwSCompModule2CompressedVcCount 2.1.866.20.1.25.70.1.3
The value of this object defines the maximum number of the virtual channels that may be simultaneously compressed by the module 0 of the equipment. The authorized values are '0..2048'. The default value is '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048  

fcwSCompAlgorithmSelection 2.1.866.20.1.25.70.1.4
The value of this object which compression algorithm is used by the equipment. It can use an algorithm compatible to which one used on equipment with version 9 software or version 10 software. It can also choise the right one automatically. The default value is 'auto'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), v9Compatible(2), v10Compatible(3)  

fcwSerReliableVirtualCircuits 2.1.866.20.1.25.70.2
OBJECT IDENTIFIER    

fcwSRvcReliableVcCount 2.1.866.20.1.25.70.2.1
The value of this object defines the maximum number of simultaneously reliable virtual circuits in the equipment. The reliable virtual circuits may be enabled at the logical port level. The authorized values are '0..255. The default value is '20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fcwSRvcFirstDataPacketTimer 2.1.866.20.1.25.70.2.2
The value of this object is the waiting time between the call connected packet and the first data packet which there is clearing beyond. This parameter is pertinent only if the fast select facility is used. The authorized values are '1..254'. The default value is '12'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fcwSRvcRestoreOutgoingCallRetryCount 2.1.866.20.1.25.70.2.3
The value of this object indicates how many times the equipment will try to send a call packet to restore the virtual circuit wich has been unintentionnaly cleared. The possible values are : '1..254'. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fcwSRvcRestoreMinimumRecallTimer 2.1.866.20.1.25.70.2.4
The value of this object specifies the minimum recall time (in seconds) between two successive calls. The authorized values are '1..254'. The default value is '20'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

fcwSRvcRestoreIncomingCallTimer 2.1.866.20.1.25.70.2.5
The value of this object is the time between a new connection request and the reception of the corresponding call connected packet which there is clearing beyond. The authorized values are '10..2540'. The default value is '120'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2540  

fcwSRvcRestoreOutgoingCallDelay 2.1.866.20.1.25.70.2.6
When it is not possible to restore the network connection, the standard forces to not use the called reference number during the value of this object. The authorized values are '10..2540'. The default value is '120'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2540  

fcwSRvcKWindowSize 2.1.866.20.1.25.70.2.7
The value of this object indicates the maximum number (K) of sequentially numbered I frames that the equipment may have outstanding (i.e.. unacknowledged) at any given time. The authorized values are '1..127'. The default value is '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fcwSRvcFastSelectUse 2.1.866.20.1.25.70.2.8
The value of this object specifies whether the equipment uses the fast select facility or not. The default value is 'onk'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcwSRvcOutputMarkers 2.1.866.20.1.25.70.2.9
The value of this object specifies the behaviour of the equipment with respect to the outgoing facility markers. The authorized values are : noCheck : no checking, remove : the markers are not transmitted, check : according to the following table : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | packet | facility marker | | |~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | 0000 (1) | 00FF (2) | 000F (3) | |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | call |no checking |clearing (5)|no checking| |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | call | | | | |connected|clearing (4)|no checking |no checking| |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | clear | - | - |no checking| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ (1) : registration codes, non-x25 facilities provided by the network in case of intranetwork calls, non-x25 facilities provided by the network to which the calling DTE is connected in case of internetwork calls (2) : non-x25 facilities provided by the network to which the calling DTE is connected in case of intranetwork calls (3) : CCITT-specified DTE facilities (4) : diagnostic to local equipment = 03 42, diagnostic to remote equipment = 11 42 (5) : diagnostic to local equipment = 03 42 The default value is 'noCheck'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCheck(1), check(2), remove(3)  

fcwSRvcConversionAimedPoint 2.1.866.20.1.25.70.2.10
The value of this object indicates whether the 'aimed point' address conversion is enabled or not. This conversion consists in making the routing process work not with the called address from the call packet but with a substituted address according to the address conversion table (see fcwAddrConvIncomingCallTable). Therefore this reduces the number of entries of the routing tables if several called addresses are converted to same 'aimed point' address. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcwSRvcConversionIncomingCall 2.1.866.20.1.25.70.2.11
The value of this object indicates which address field are converted on an incoming call. The authorized values are : off : no address field conversion, callingAddress : conversion of the calling address field according to the contains of fcwAddrConvIncomingCallTable, calledAddress : conversion of the called address field according to the contains of fcwAddrConvIncomingCallTable, callingAddressAndCalledAddress : conversion of the calling and called address fields according to the contains of fcwAddrConvIncomingCallTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fcwSRvcConversionOutgoingCall 2.1.866.20.1.25.70.2.12
The value of this object indicates which address field are converted on an outgoing call. The authorized values are : off : no address field conversion, callingAddress : conversion of the calling address field according to the contains of fcwAddrConvOutgoingCallTable, calledAddress : conversion of the called address field according to the contains of fcwAddrConvOutgoingCallTable, callingAddressAndCalledAddress : conversion of the calling and called address fields according to the contains of fcwAddrConvOutgoingCallTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fcwSRvcConversionAddressCheck 2.1.866.20.1.25.70.2.13
The value of this object indicates the behaviour of the equipment when a requested address conversion can not be made because the address is not found in the address conversion tables (fcwAddrConvIncomingCallTable or fcwAddrConvOutgoingCallTable). In this case the call will be cleared when 'checking' is enabled. The authorized values are : off : no checking, onIncomingCall : checking on incoming calls, onOutgoingCall : checking on outgoing calls, onIcomingCallAndOutgoingCall : checking on incoming and outgoing calls. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(4)  

fcwSerReselectionX29 2.1.866.20.1.25.70.3
OBJECT IDENTIFIER    

fcwSResLogChannelCount 2.1.866.20.1.25.70.3.1
The value of this object is the number of logical Channels. The authorized values are '0..255. The default value is '200'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fcwSResProtocolIdentifierTransmission 2.1.866.20.1.25.70.3.2
The value of this object indicates whether the protocol identifier is transmitted or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcwSResConversionAimedPoint 2.1.866.20.1.25.70.3.10
The value of this object indicates whether the 'aimed point' address conversion is enabled or not. This conversion consists in making the routing process work not with the called address from the call packet but with a substituted address according to the address conversion table (see fcwAddrConvIncomingCallTable). Therefore this reduces the number of entries of the routing tables if several called addresses are converted to same 'aimed point' address. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcwSResConversionIncomingCall 2.1.866.20.1.25.70.3.11
The value of this object indicates which address field are converted on an incoming call. The authorized values are : off : no address field conversion, callingAddress : conversion of the calling address field according to the contains of fcwAddrConvIncomingCallTable, calledAddress : conversion of the called address field according to the contains of fcwAddrConvIncomingCallTable, callingAddressAndCalledAddress : conversion of the calling and called address fields according to the contains of fcwAddrConvIncomingCallTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fcwSResConversionOutgoingCall 2.1.866.20.1.25.70.3.12
The value of this object indicates which address field are converted on an outgoing call. The authorized values are : off : no address field conversion, callingAddress : conversion of the calling address field according to the contains of fcwAddrConvOutgoingCallTable, calledAddress : conversion of the called address field according to the contains of fcwAddrConvOutgoingCallTable, callingAddressAndCalledAddress : conversion of the calling and called address fields according to the contains of fcwAddrConvOutgoingCallTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fcwSResConversionAddressCheck 2.1.866.20.1.25.70.3.13
The value of this object indicates the behaviour of the equipment when a requested address conversion can not be made because the address is not found in the address conversion tables (fcwAddrConvIncomingCallTable or fcwAddrConvOutgoingCallTable). In this case the call will be cleared when 'checking' is enabled. The authorized values are : off : no checking, onIncomingCall : checking on incoming calls, onOutgoingCall : checking on outgoing calls, onIcomingCallAndOutgoingCall : checking on incoming and outgoing calls. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(4)  

fcwSerDynamicRouting 2.1.866.20.1.25.70.4
OBJECT IDENTIFIER    

fcwSDynDynamicRouting 2.1.866.20.1.25.70.4.1
Mode de fonctionnement RAD
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(3)  

fcwSDynPassword 2.1.866.20.1.25.70.4.2
Mode de passe fonction d'exploitation RAD
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..6)  

fcwSDynNeighborMaxCount 2.1.866.20.1.25.70.4.3
Nb max de LSPDU memorisees
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..250  

fcwSDynLspAgingTimer 2.1.866.20.1.25.70.4.4
Duree de stockage d'un LSPDU
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fcwSDynLspRetransRequestTimer 2.1.866.20.1.25.70.4.5
Duree de stockage minimum declanchant une demande de mise a jour d'un LSPDU
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fcwSDynLspRetransmissionTimer 2.1.866.20.1.25.70.4.6
Periode de diffusion de la topologie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fcwSDynRouteCalculationTimer 2.1.866.20.1.25.70.4.7
Periode de calcul des routes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fcwSDynRouteCalculLockingTimer 2.1.866.20.1.25.70.4.8
Duree de verrouillage du calcul des routes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..2500  

fcwSerClearAnalysisTable 2.1.866.20.1.25.70.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwSerClearAnalysisEntry

fcwSerClearAnalysisEntry 2.1.866.20.1.25.70.5.1
An entry of fcwSerClearAnalysisTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwSerClearAnalysisEntry  

fcwSClearAnalysId 2.1.866.20.1.25.70.5.1.1
The value of this object identifies one and only one entry in the table (index)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..17  

fcwSClearAnalysStatus 2.1.866.20.1.25.70.5.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwSClearAnalysCause 2.1.866.20.1.25.70.5.1.3
The value of this object indicates which cause(s) is taken into account in case of clear indication. Possible values are : 00..FF TT (all DTE clear indications) TC (all DCE clear indications) * (any clearing cause)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

fcwSClearAnalysDiag 2.1.866.20.1.25.70.5.1.4
The value of this object indicates which diagnostic is taken into account in case of clear indication. Possible values are : 00..FF * (any clearing diagnostic)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

fcwSerQOSX25 2.1.866.20.1.25.70.10
OBJECT IDENTIFIER    

fcwSQOSX25Table 2.1.866.20.1.25.70.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwSQOSX25Entry

fcwSQOSX25Entry 2.1.866.20.1.25.70.10.1.1
An entry of fcwSQOSX25Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwSQOSX25Entry  

fcwSQOSX25CalledAddress 2.1.866.20.1.25.70.10.1.1.1
Called Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcwSQOSX25CallingAddress 2.1.866.20.1.25.70.10.1.1.2
Calling Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcwSQOSX25CUDProfileId 2.1.866.20.1.25.70.10.1.1.3
CUD Profile Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..100  

fcwSQOSX25Status 2.1.866.20.1.25.70.10.1.1.4
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwSQOSX25PriorityLevel 2.1.866.20.1.25.70.10.1.1.5
Priority Level
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

fcwSQOSX25QOSProfileId 2.1.866.20.1.25.70.10.1.1.6
QOS Profile Id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

fcwSQOSX25Cos 2.1.866.20.1.25.70.10.1.1.7
COS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1), vbr-rt(2)  

fcwSQOSX25TrafficManagementStrategy 2.1.866.20.1.25.70.10.1.1.8
Traffic Management Strategy
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER discardButNotDelay(1), delayButNotDiscard-Bc(3), delayButNotDiscard-BcBe(4)  

fcwSCUDProfilesTable 2.1.866.20.1.25.70.10.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwSCUDProfilesEntry

fcwSCUDProfilesEntry 2.1.866.20.1.25.70.10.2.1
An entry of fcwSCUDProfilesTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwSCUDProfilesEntry  

fcwSCUDProfilesId 2.1.866.20.1.25.70.10.2.1.1
CUD Profile Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..100  

fcwSCUDProfilesStatus 2.1.866.20.1.25.70.10.2.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwSCUDProfilesCUD 2.1.866.20.1.25.70.10.2.1.3
Donnees d'appel hexa CUD
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(13)  

fcwSQOSProfilesTable 2.1.866.20.1.25.70.10.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcwSQOSProfilesEntry

fcwSQOSProfilesEntry 2.1.866.20.1.25.70.10.3.1
An entry of fcwSQOSProfilesTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcwSQOSProfilesEntry  

fcwSQOSProfilesId 2.1.866.20.1.25.70.10.3.1.1
QOS Profile Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..100  

fcwSQOSProfilesStatus 2.1.866.20.1.25.70.10.3.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcwSQOSProfilesCIR 2.1.866.20.1.25.70.10.3.1.3
CIR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcwSQOSProfilesCIRmin 2.1.866.20.1.25.70.10.3.1.4
CIRmin
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcwSQOSProfilesBc 2.1.866.20.1.25.70.10.3.1.5
Bc
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcwSQOSProfilesBe 2.1.866.20.1.25.70.10.3.1.6
Be
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcVirtualPorts 2.1.866.20.1.30
OBJECT IDENTIFIER    

fcvVirtualPortTable 2.1.866.20.1.30.1
This table defines the virtual ports. Through a virtual port the bridge and the IP, IPX and CLNP routers can communicate with bridges and routers taking place inside a particular virtual network. These communications may use a Local Area Network (LAN), namely the virtual network matches the LAN, or Wide Area Networks (WAN), namely the virtual network matches a group of remote bridges or routers. Each module of the equipment has its own virtual ports. The module 0 can enable bridge forwarding, IP (Internet Protocol) routing, IPX (Internetwork Packet eXchange : Novell protocol) routing and CLNP (ConnectionLess Network Protocol) routing. The modules 1 and 2 can only act as IP host. So each of these two modules needs one remote VP when its SNMP agent must exchange SNMP datas with an SNMP manager. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fcvVpStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcvVirtualPortEntry

fcvVirtualPortEntry 2.1.866.20.1.30.1.1
An entry of fcvVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcvVirtualPortEntry  

fcvVpVirtualPortId 2.1.866.20.1.30.1.1.1
The value of this object identifies one and only one virtual port. Through a virtual port the bridge and the IP, IPX and CLNP routers can communicate with bridges and routers taking place inside a particular virtual network. These communications may use a Local Area Network (LAN), namely the virtual network matches the LAN, or Wide Area Networks (WAN), namely the virtual network matches a group of remote bridges or routers. This is a decimal integer in the range 0 to 11.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fcvVpStatus 2.1.866.20.1.30.1.1.2
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcvVpType 2.1.866.20.1.30.1.1.3
The value of this object indicates whether this virtual port is: local : the virtual network is a Local Area Network (LAN), or remote : the virtual network is a group of remote equipments which may be reached through Wide Area Networks (WAN). The default value is 'remote'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER local(1), remote(2)  

fcvVpModuleId 2.1.866.20.1.30.1.1.4
The value of this object indicates the module of the equipment to which this virtual port belongs to. Each module of the equipment has its own virtual ports. The module 0 can enable bridge forwarding, IP (Internet Protocol) routing, IPX (Internetwork Packet eXchange : Novell protocol) routing and CLNP (ConnectionLess Network Protocol) routing. The modules 1 and 2 can only act as IP host. So each of these two modules needs one remote VP when its SNMP agent must exchange SNMP datas with an SNMP manager. This is a decimal integer in the range 0 to 2. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2  

fcvLocalVirtualPorts 2.1.866.20.1.30.10
OBJECT IDENTIFIER    

fcvLocalVirtualPortTable 2.1.866.20.1.30.10.1
This table defines the characteristics of the local virtual ports. It is not possible to add or delete an entry of this table (each entry corresponds, in fcvVirtualPortTable, to one instance of fcvVpType equal to 'local').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcvLocalVirtualPortEntry

fcvLocalVirtualPortEntry 2.1.866.20.1.30.10.1.1
An entry of fcvLocalVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcvLocalVirtualPortEntry  

fcvLvpVirtualPortId 2.1.866.20.1.30.10.1.1.1
The value of this object identifies one and only one local virtual port. Each local virtual port corresponds, in fcvVirtualPortTable, to one instance of fcvVpType equal to 'local'. This is a decimal integer in the range 0 to 11.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fcvLvpLogicalPortId 2.1.866.20.1.30.10.1.1.2
The value of this object indicates the logical port to which this local virtual port is associated. This logical port must exist in fclEthernetTable. This is a decimal integer in the range 0 to 131. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..181  

fcvLvpFiltering 2.1.866.20.1.30.10.10
OBJECT IDENTIFIER    

fcvLvpFltConditionTable 2.1.866.20.1.30.10.10.1
This table defines the conditions which may be used to make filters in fcvLvpFltFilterTable. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fcvLvpFltCondStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcvLvpFltConditionEntry

fcvLvpFltConditionEntry 2.1.866.20.1.30.10.10.1.1
An entry of fcvLvpFltConditionTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcvLvpFltConditionEntry  

fcvLvpFltCondConditionId 2.1.866.20.1.30.10.10.1.1.1
The value of this object identifies one and only one condition. This condition identifier is used in fcvFltFilterTable to make filters. This is a decimal integer in the range 0 to 99.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

fcvLvpFltCondStatus 2.1.866.20.1.30.10.10.1.1.2
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcvLvpFltCondOffset 2.1.866.20.1.30.10.10.1.1.3
The value of this object selects the four bytes as of which are applied the mask defined by fcvLvpFltCondMask and the value defined by fcvLvpFltCondValue. Examples : Offset at MAC level : Destination MAC address (6 bytes): 0 Source MAC address (6 bytes) : 6 PID field (2 bytes) : 12 Offset at IP level with Ethernet encapsulation : Protocol (1 byte): 23 Source IP address (4 bytes): 26 Destination IP address (4 bytes): 30 This is a decimal integer in the range 0 to 1513. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1513  

fcvLvpFltCondMask 2.1.866.20.1.30.10.10.1.1.4
The value of this object defines the mask indicating the bits of the four bytes selected by fcvLvpFltCondOffset which are to be compared with the bits of the four bytes defined by fcvLvpFltCondValue. This is a four-bytes octet string with 8 digits in the range 0 to F, The default value is 'FF FF FF FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcvLvpFltCondValue 2.1.866.20.1.30.10.10.1.1.5
The value of this object defines the values of the bits with which are compared, according to the mask defined by fcvLvpFltCondMask, the bits of the four bytes selected by fcvLvpFltCondOffset. This is a four-bytes octet string with 8 digits in the range 0 to F, The default value is 'FF FF FF FF'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcvLvpFltFilterTable 2.1.866.20.1.30.10.10.2
This table defines the filters which may be used in the filtering table (fcvLvpFltFilteringTable). One filter is a combination of up to three conditions from fcvLvpFltConditionTable. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fcvLvpFltFilterStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcvLvpFltFilterEntry

fcvLvpFltFilterEntry 2.1.866.20.1.30.10.10.2.1
An entry of fcvLvpFltFilterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcvLvpFltFilterEntry  

fcvLvpFltFilterId 2.1.866.20.1.30.10.10.2.1.1
The value of this object identifies one and only one filter. This filter is a combination of one, two or three conditions defined in fcvLvpFltConditionTable. A filter selects the received frames which simultaneously verify those of the three conditions which are actually used for this filter. When several filters are simultaneously used on the same virtual port, the equipment analyses them in the incremental order of this filter identifier until whether the current frame is selected by one of these filters or all of them are analysed. So the numbering order must be done with a particular attention. This is a decimal integer in the range 0 to 199.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcvLvpFltFilterStatus 2.1.866.20.1.30.10.10.2.1.2
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcvLvpFltFilterCondition1Id 2.1.866.20.1.30.10.10.2.1.3
The value of this object specifies a first condition used by this filter. This condition must exist in fcvLvpFltConditionTable. Important : by convention, the condition identifier increased by 100 allows the opposite condition to be applied : the received frames not verifying this condition are then selected.. This is a decimal integer in the range 0 to 199. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fcvLvpFltFilterCondition2Id 2.1.866.20.1.30.10.10.2.1.4
The value of this object specifies a second condition used by this filter. This condition must exist in fcvLvpFltConditionTable. Important : by convention, the condition identifier increased by 100 allows the opposite condition to be applied : the received frames not verifying this condition are then selected.. This is a decimal integer in the range 0 to 199. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fcvLvpFltFilterCondition3Id 2.1.866.20.1.30.10.10.2.1.5
The value of this object specifies a third condition used by this filter. This condition must exist in fcvLvpFltConditionTable. Important : by convention, the condition identifier increased by 100 allows the opposite condition to be applied : the received frames not verifying this condition are then selected.. This is a decimal integer in the range 0 to 199. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fcvLvpFltFilteringTable 2.1.866.20.1.30.10.10.3
This table is the filtering table. It defines which filters are used by each virtual port to select the frames to which is applied the reject/accept decision. By default, if no filter has been configured or if the frame is not selected by any filter, it is accepted. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fcvLvpFltFilteringStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcvLvpFltFilteringEntry

fcvLvpFltFilteringEntry 2.1.866.20.1.30.10.10.3.1
An entry of fcvLvpFltFilteringTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcvLvpFltFilteringEntry  

fcvLvpFltFilteringVirtualPortId 2.1.866.20.1.30.10.10.3.1.1
The value of this object identifies one and only one local virtual port. This local virtual port must exist in fcvLocalVirtualPortTable. Each local virtual port may use several filters : the equipment analyses them in the incremental order of the filter identifier until whether the current frame is selected by one of these filters or all of them are analysed. This is a decimal integer in the range 0 to 11.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fcvLvpFltFilteringFilterId 2.1.866.20.1.30.10.10.3.1.2
The value of this object identifies one filter used by this local virtual port. This filter must exist in fcvFltFilterTable. When several filters are simultaneously used on the same virtual port, the equipment analyses them in the incremental order of this filter identifier. So the numbering order must be done with a particular attention. Important : , the value 200 designates a special filter grouping all the frames received by this VP which were not selected by the other filters applied to this VP. This special filter is the last analysed filter for this VP. This filtering process concerns all the traffic received on one of the IP, IPX or CNLP routers or bridge whereas the filtering described in fciFlowTable is made only at the IP level. This is a decimal integer in the range 0 to 200.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

fcvLvpFltFilteringStatus 2.1.866.20.1.30.10.10.3.1.3
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcvLvpFltFilteringType 2.1.866.20.1.30.10.10.3.1.4
The value of this object specifies whether the frames selected by the filter are rejected or accepted : deny : the frames selected by the filter are rejected, therefore the frames not selected are accepted, permit : the frames selected by the filter are accepted, therefore the frames not selected are rejected. The default value is 'deny'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER deny(1), permit(2)  

fcvRemoteVirtualPorts 2.1.866.20.1.30.20
OBJECT IDENTIFIER    

fcvRvpCompression 2.1.866.20.1.30.20.1
For all the connections described in fcvRvpConnectionTable, the value of this object indicates the compression enabling for each direction : off : compression is disabled, networkToSubscriber : compression is enabled for the flow from the remote peer to the equipment, subscriberToNetwork : compression is enabled for the flow from the equipment to the remote peer, bothway : compression is enabled for the two flows from and to the equipment. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), networkToSubscriber(2), subscriberToNetwork(3), bothway(4)  

fcvRvpCompressNegotiation 2.1.866.20.1.30.20.2
The value of this object indicates, when the compression is active, whether the compression facility is negociated or not and, if negociated, the optional/mandatory status : off : negociation is disabled, onOptionalCompression : negociation is enabled and compression is optional, onMandatoryCompression : negociation is enabled and compression is mandatory. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onOptionalCompression(2), onMandatoryCompression(3)  

fcvRvpCompressScrambling 2.1.866.20.1.30.20.3
The value of this object indicates, when the compression is active, whether the scrambling is enabled or not. @ The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcvRvpCompressMultiPacketsTimer 2.1.866.20.1.30.20.4
The value of this object is the multi-packets timer in milliseconds. When the compression is active, the multi-packets function is specified in order to reduce the number of single packets (i.e., without 'More Data mark' = bit M set to 0) transmitted to the remote peer by grouping several packets in an only one compressed output packet. The value 0 disables this function (i.e., each single packet is individually compressed and sent). So to enable this function this timer must be different from 0 on both the local equipment and the remote peer (even when the compression direction is set to 'subscriberToNetwork' or 'subscriberToNetwork'). This timer starts when the equipment begins to fill a new compressed output packet and it is normally stopped when this packet is sent. When this timer runs out the equipment sends this compressed packet even if it is not full. This is a decimal integer in the range 0 to 1500 by step of 100. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

fcvRvpReliableVirtualCircuit 2.1.866.20.1.30.20.5
For all the connections described in fcvRvpConnectionTable, the value of this object indicates whether the Reliable Virtual Circuit (RVC) service is enabled or not : off : no RVC, the VCs are considered as normal VCs, no particular processing, on : all calls transmitted by the subscriber establish RVCs, it is also possible to receive calls with RVC option. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcvRvpBe 2.1.866.20.1.30.20.6
Entrant BE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcvRvpConversionAimedPoint 2.1.866.20.1.30.20.7
Conversion adresse : point vise
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcvRvpConversionIncomingCall 2.1.866.20.1.30.20.8
Conversion d'adresse sur appel entrant
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fcvRvpConversionOutgoingCall 2.1.866.20.1.30.20.9
Conversion adresse sur appel sortant
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), callingAddress(2), calledAddress(3), callingAddressAndCalledAddress(4)  

fcvRvpConversionAddressCheck 2.1.866.20.1.30.20.10
Conversion adresse : controle de la presence dans les tables de conversion
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(4)  

fcvRvpConvMultiCalledAddrInCall 2.1.866.20.1.30.20.11
Numero d'identification pour conversion d'adresse d'appele multi-criteres en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fcvRvpConvMultiCallingAddrInCall 2.1.866.20.1.30.20.12
Numero d'identification pour conversion d'adresse d'appelant multi-criteres en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fcvRvpConvMultiCalledAddrOutCall 2.1.866.20.1.30.20.13
Numero d'identification pour conversion d'adresse d'appele multi-criteres en sortie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fcvRvpConvMultiCallingAddrOutCall 2.1.866.20.1.30.20.14
Numero d'identification pour conversion d'adresse d'appelant multi-criteres en sortie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fcvRvpCallAcceptwithReverseCharging 2.1.866.20.1.30.20.15
Acceptation appel avec TAD
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fcvRvpCos 2.1.866.20.1.30.20.20
For all the connections described in fcvRvpConnectionTable, the value of this object indicates the Class Of Service (COS) desired on a Frame Relay network. This object is meaningless if the call is established on another transport network. ubr : undefined bit rate, vbr : variable bit rate. The default value is 'ubr'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1)  

fcvRvpCir 2.1.866.20.1.30.20.21
For all the connections described in fcvRvpConnectionTable, the value of this object indicates the Committed Infomation Rate (CIR) in bits per second desired on a Frame Relay network. This object is meaningless if the call is established on another transport network. The CIR is the subscriber data rate that the Frame Relay network commits to deliver under normal network conditions. This is a decimal integer in the range 600 to 2048000. Only the following values are valid : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | # | value | # | value | # | value | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | 0 | 0 | 17 | 144000 | 33 | 1152000 | | 2 | 600 | 18 | 192000 | 34 | 1216000 | | 3 | 1200 | 19 | 256000 | 35 | 1280000 | | 4 | 2400 | 20 | 320000 | 36 | 1344000 | | 5 | 4800 | 21 | 384000 | 37 | 1408000 | | 6 | 9600 | 22 | 448000 | 38 | 1472000 | | 7 | 14400 | 23 | 512000 | 39 | 1536000 | | 8 | 19200 | 24 | 576000 | 40 | 1600000 | | 9 | 32000 | 25 | 640000 | 41 | 1664000 | | 10 | 38400 | 26 | 704000 | 42 | 1728000 | | 11 | 48000 | 27 | 768000 | 43 | 1792000 | | 12 | 56000 | 28 | 832000 | 44 | 1856000 | | 13 | 64000 | 29 | 896000 | 45 | 1920000 | | 14 | 72000 | 30 | 960000 | 46 | 1984000 | | 15 | 96000 | 31 | 1024000 | 47 | 2048000 | | 16 | 128000 | 32 | 1088000 | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ The default value is '4294967295' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 600..2048000  

fcvRvpMinCir 2.1.866.20.1.30.20.22
For all the connections described in fcvRvpConnectionTable, the value of this object indicates the minimum Committed Infomation Rate (CIR) in bits per second desired on a Frame Relay network. This object is meaningless if the call is established on another transport network. This is a decimal integer in the range 600 to 2048000. Only the following values are valid : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | # | value | # | value | # | value | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | 0 | 0 | 17 | 144000 | 33 | 1152000 | | 2 | 600 | 18 | 192000 | 34 | 1216000 | | 3 | 1200 | 19 | 256000 | 35 | 1280000 | | 4 | 2400 | 20 | 320000 | 36 | 1344000 | | 5 | 4800 | 21 | 384000 | 37 | 1408000 | | 6 | 9600 | 22 | 448000 | 38 | 1472000 | | 7 | 14400 | 23 | 512000 | 39 | 1536000 | | 8 | 19200 | 24 | 576000 | 40 | 1600000 | | 9 | 32000 | 25 | 640000 | 41 | 1664000 | | 10 | 38400 | 26 | 704000 | 42 | 1728000 | | 11 | 48000 | 27 | 768000 | 43 | 1792000 | | 12 | 56000 | 28 | 832000 | 44 | 1856000 | | 13 | 64000 | 29 | 896000 | 45 | 1920000 | | 14 | 72000 | 30 | 960000 | 46 | 1984000 | | 15 | 96000 | 31 | 1024000 | 47 | 2048000 | | 16 | 128000 | 32 | 1088000 | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ The default value is '4294967295' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcvRvpConnectionTable 2.1.866.20.1.30.20.23
This table defines the connections to each remote bridge or router on WAN virtual networks. Each connection is attached to one remote virtual port of a module of the equipment. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fcvRvpConnStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcvRvpConnectionEntry

fcvRvpConnectionEntry 2.1.866.20.1.30.20.23.1
An entry of fcvRvpConnectionTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcvRvpConnectionEntry  

fcvRvpConnRemoteAddress 2.1.866.20.1.30.20.23.1.1
The value of this object is the X121 address of the called remote bridge or router. This value is the called address specified in the call packet sent from this module. Several connections using different encapsulations may be established with the same remote equipment. But when multiplexing is used it must be the only encapsulation used with this particular remote equipment. This is a eight-bytes octet string with : up to 15 digits in the range 0 to 9, mandatory 'F' digits to pad the value until a total of 16 digits (the equipment configurator does not need this final padding).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcvRvpConnEncapsulation 2.1.866.20.1.30.20.23.1.2
The value of this object indicates the protocol(s) to be transferred on the connection : multiplexing : all protocols may be transported on this connection and it must be the only encapsulation specified for this X121 address, bridge : bridge protocol, bridgeSpecific : bridge specific protocol, ip : internet protocol, ipx : internetwork packet exchange protocol, ipxSpecific : specific internetwork packet exchange protocol, clnp : connectionless network protocol.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER multiplexing(1), bridge(10), bridgeSpecific(11), ip(20), ipx(30), ipxSpecific(31), clnp(40)  

fcvRvpConnConnectionId 2.1.866.20.1.30.20.23.1.3
When several connections are established with the same encapsulation for the same remote equipment, the value of this object identifies this particular connection. This connection identifier must also be configured on the remote equipment. When only one connection is established with the same encapsulation for the same remote equipment, the value of this object is '255' (blank value on the equipment configurator) meaning 'unused'. This is a decimal integer in the range 1 to 8 or equal to 255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

fcvRvpConnStatus 2.1.866.20.1.30.20.23.1.4
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcvRvpConnFlowTypeMask 2.1.866.20.1.30.20.23.1.5
The value of this object is a mask specifying the families (defined by fciFlowType) which have to transit via this connection. Example : let us suppose that fciFlowTable defines the content of families 2, 8, 16, 32 and 64 and this connection is set up to process families 8, 16 and 32. The mask therefore takes on value : 8 + 16 + 32 = 56. If two connections to the same address with the same encapsulation select the same family, the family will be oriented towards the first of these connections (increasing order of the connection identifiers). By convention, the value 255 selects, out of all the flows directed towards a WAN address, not only all the specified flows (i.e., defined in fciFlowTable) but also the unspecified flows (i.e., not defined in fciFlowTable). This is the default value to be used when flow separation is not being used. This is a decimal integer in the range 1 to 255. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcvRvpConnModule0VpId 2.1.866.20.1.30.20.23.1.10
The value of this object indicates the virtual port used by the Bridge and Router functions of the module 0 to communicate with the remote equipment. This VP must exist in fcvVirtualPortTable and must be a remote VP. When this connection is not processed by the module 0 this value is set to '255' (blank value on the equipment configurator). This is a decimal integer in the range 0 to 11. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..11  

fcvRvpConnModule1VpId 2.1.866.20.1.30.20.23.1.11
The value of this object indicates the virtual port used by the Bridge and Router functions of the module 1 to communicate with the remote equipment. This VP must exist in fcvVirtualPortTable and must be a remote VP. When this connection is not processed by the module 1 this value is set to '255' (blank value on the equipment configurator). This is a decimal integer in the range 0 to 11. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..11  

fcvRvpConnModule2VpId 2.1.866.20.1.30.20.23.1.12
The value of this object indicates the virtual port used by the Bridge and Router functions of the module 2 to communicate with the remote equipment. This VP must exist in fcvVirtualPortTable and must be a remote VP. When this connection is not processed by the module 2 this value is set to '255' (blank value on the equipment configurator). This is a decimal integer in the range 0 to 11. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..11  

fcvRvpConnCallDirection 2.1.866.20.1.30.20.23.1.20
The value of this object defines the mode used to establish this connection. The authorized values are : calling : the caller is this equipment (at initialization time), called : the caller is the remote this equipment (at initialization time), auto : automatic choise between 'calling' and 'called' (at initialization time with call collision processing), datagram : the caller is this equipment or the remote one (at any time) depending on which of them is the first one that wishes send datas. The default value is 'datagram'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER calling(1), called(2), auto(3), datagram(4)  

fcvRvpConnGrouping 2.1.866.20.1.30.20.23.1.21
The value of this object indicates whether the frame grouping/separation service (according to a specific proprietary encapsulation) is enabled or not. It requires the configuration of the fast select facility accross the WAN network. The frame grouping option is compatible only with the bridgeSpecific and ip encapsulations (see fcvRvpConnEncapsulation). The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcvRvpConnMinimumRecallTimer 2.1.866.20.1.30.20.23.1.22
The value of this object is the minimum recall timer in seconds. This timer starts when the equipment initiates the call and it is normally stopped when this call is successfull. When this timer runs out the equipment initiates a new call. This is a decimal integer in the range 0 to 990 by step of 10. The default value is '100'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fcvRvpConnInactivityTimer 2.1.866.20.1.30.20.23.1.23
The value of this object is the inactivity timer in seconds. This timer starts one minute after the call is successfull. When this timer runs out, if there was traffic on this call during this period, this timer is re-started otherwise this call is cleared. This is a decimal integer in the range 0 to 2540 by step of 10. The default value is '30'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2540  

fcvRvpConnCir 2.1.866.20.1.30.20.23.1.24
The value of this object indicates, for this connection, the Committed Infomation Rate (CIR) in bits per second desired on a Frame Relay network. This object is meaningless if the call is established on another transport network. The CIR is the subscriber data rate that the Frame Relay network commits to deliver under normal network conditions. This is a decimal integer in the range 600 to 2048000. Only the following values are valid : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | # | value | # | value | # | value | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | 0 | 0 | 17 | 144000 | 33 | 1152000 | | 2 | 600 | 18 | 192000 | 34 | 1216000 | | 3 | 1200 | 19 | 256000 | 35 | 1280000 | | 4 | 2400 | 20 | 320000 | 36 | 1344000 | | 5 | 4800 | 21 | 384000 | 37 | 1408000 | | 6 | 9600 | 22 | 448000 | 38 | 1472000 | | 7 | 14400 | 23 | 512000 | 39 | 1536000 | | 8 | 19200 | 24 | 576000 | 40 | 1600000 | | 9 | 32000 | 25 | 640000 | 41 | 1664000 | | 10 | 38400 | 26 | 704000 | 42 | 1728000 | | 11 | 48000 | 27 | 768000 | 43 | 1792000 | | 12 | 56000 | 28 | 832000 | 44 | 1856000 | | 13 | 64000 | 29 | 896000 | 45 | 1920000 | | 14 | 72000 | 30 | 960000 | 46 | 1984000 | | 15 | 96000 | 31 | 1024000 | 47 | 2048000 | | 16 | 128000 | 32 | 1088000 | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ The default value is '4294967295' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 600..2048000  

fcvRvpConnCos 2.1.866.20.1.30.20.23.1.25
Requested Class of Service for this connection, the Cos can be configured more globally.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), global(4), vbr(1), vbr-rt(2)  

fcvRvpConnBe 2.1.866.20.1.30.20.23.1.26
Be
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcSna 2.1.866.20.1.32
OBJECT IDENTIFIER    

fcsnaLocalVirtualPort 2.1.866.20.1.32.1
OBJECT IDENTIFIER    

fcsnaLvpLocalLanPuTable 2.1.866.20.1.32.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcsnaLvpLocalLanPuEntry

fcsnaLvpLocalLanPuEntry 2.1.866.20.1.32.1.1.1
An entry of fcsnaLvpLocalLanPuTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcsnaLvpLocalLanPuEntry  

fcsnaLvpLlpVirtualPortId 2.1.866.20.1.32.1.1.1.1
VP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fcsnaLvpLlpPuId 2.1.866.20.1.32.1.1.1.2
Physical Unit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1999  

fcsnaLvpLlpStatus 2.1.866.20.1.32.1.1.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcsnaLvpParameters 2.1.866.20.1.32.1.10
OBJECT IDENTIFIER    

fcsnaLvpParamLinkType 2.1.866.20.1.32.1.10.1
The type of frontal must be connected to a primary link-station or negociable link station that will become the primary. The type of remote must be connected to a secondary link-station or negociable link station that will become the secondary. The default value is 'frontal'
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER frontal(1), remote(2)  

fcsnaLvpParamFrameFormat 2.1.866.20.1.32.1.10.2
The unit supports IEEE 802.3 and V2 DIX Ethernet frame format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER e802-3(1), v2-DIX(2)  

fcsnaLvpParamLocalTest 2.1.866.20.1.32.1.10.3
This feature is used in 'frontal' mode. If this feature is set to on, and when the internal connection is established, it will send a local test frame to the primary link-station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcsnaLvpParamCallDirection 2.1.866.20.1.32.1.10.4
Frontal mode is called. Remote mode is calling.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER called(1), calling(2)  

fcsnaLvpMacAddressTrans 2.1.866.20.1.32.1.10.5
MAC address translation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcsnaLvpParamT1 2.1.866.20.1.32.1.10.10
T1 Reply timer. A link-station uses T1 to detect a failure to receive a required acknowlegment or response. T1 runs when there are acknowlegments outstanding, it is reset when acknowlegments are received.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25000  

fcsnaLvpParamN2 2.1.866.20.1.32.1.10.11
The maximum number of transmissions. If the reply timer expires for whatever reason, an S-frame with poll bit set is sent to sollicit a response from remote link-station. If there is still no response after N2 retry, the link is deemed to be inoperative.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fcsnaLvpParamT2 2.1.866.20.1.32.1.10.12
Receiver acknowledge timer. The end station uses this timer to delay the seding of an acknowlegment for a received I-frame LPDU. The link-station starts T2 when it receives an I-frame and resets it when it sends an acknowlegment. T2 must be less than T1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..15000  

fcsnaLvpParamN3 2.1.866.20.1.32.1.10.13
Number of I-frame LPDU's received before sending an acknowledgment.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fcsnaLvpParamNW 2.1.866.20.1.32.1.10.14
Number of acknowledgments needed to increment Ww.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fcsnaLvpParamTW 2.1.866.20.1.32.1.10.15
LLC transmit window size. This is maximum number of sequentially numbered Iframe that the link-station may have outstanding at any given time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fcsnaLvpParamRW 2.1.866.20.1.32.1.10.16
LLC receive window size. This is the maximum number of unacknowlegment sequentially numbered I-frame the link-station can receive from the remote station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fcsnaLvpParamMinRecallTimer 2.1.866.20.1.32.1.10.20
Slow call timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fcsnaLvpParamSubscriberNumber 2.1.866.20.1.32.1.10.21
The value of this object is the SB number added to the DNICZO of the equipment to make the calling address in a call sent from this logical port. The value must contain 2 digits (digits 0..9). The default value is '22'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcsnaLvpParamReliableVc 2.1.866.20.1.32.1.10.22
The value of this object is used to enable the Reliable Virtual Circuit service. The authorized values are : off : no RVC, the VCs are considered as normal VCs, no particular processing, clear : RVCs are not allowed for the subscriber, each attempt to establish a RVC provokes a clear of the connection, subscribe : all calls transmitted by the subscriber establish RVCs, it is also possible to receive calls with RVC option, check : for a link to a subscriber : when a call with RVC option is received, a RVC is established for a link to a network : the RVC option is ignored when it is present in a call sent by a local subscriber, the connection is cleared when the RVC option is present in a call sent by the network. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(3), subscribe(2), check(4)  

fcsnaLvpParamCompression 2.1.866.20.1.32.1.10.30
The value of this object indicates the compression enabling for each direction. The authorized values are : off : no compression, networkToSubscriber : compression of the flow from the remote peer to the equipment, subscriberToNetwork : compression of the flow from the equipment to the remote peer, bothway : compression of the two flows from and to the equipment. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), networkToSubscriber(2), subscriberToNetwork(3), bothway(4)  

fcsnaLvpParamCompressNegotiation 2.1.866.20.1.32.1.10.31
The value of this object indicates whether the compression facility is negociated or not and, if negociated, the optional/obligatory status. The authorized values are : off' :no negociation, onOptionalCompression : negociation but compression is optional, onMandatoryCompression : negociation and compression is mandatory. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onOptionalCompression(2), onMandatoryCompression(3)  

fcsnaLvpParamCompressScrambling 2.1.866.20.1.32.1.10.32
The value of this object indicates, when the compression is active, whether the scrambling is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcsnaLvpParamCompressMultiPacketsTimer 2.1.866.20.1.32.1.10.33
The value of this object defines the maximum waiting time, in milliseconds by steps of 100 milliseconds , which, if there is not another packet to compress, the packet of compressed packets is sent beyond (this permits to reduce the number of packets transmitted to the remote peer). The authorized values are '0..1500'. '0' means no packets grouping (i. e. : each packet is individually compressed and sent). The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

fcsnaLvpParamCos 2.1.866.20.1.32.1.10.40
Class Of Service VBR or UBR.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1)  

fcsnaLvpParamCir 2.1.866.20.1.32.1.10.41
Committed information Rate is the maximum number of bits per seconds which an end station can transmit into the network . This is the access rate of the user-network interface and it is limited by the line speed of the user-network connection and established by subscription.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 600..2048000  

fcsnaLvpParamCirMin 2.1.866.20.1.32.1.10.42
If the end station is informed about the congestion of the network, this is the minimum CIR that the end station can transmit into the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcsnaLvpParamBc 2.1.866.20.1.32.1.10.43
The Committed Burst Size is a measure for the volume of data for which the network will garantee message delivery under normal conditions. It is measured during the committed rate measurement interval (Tc).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcsnaLvpParamBe 2.1.866.20.1.32.1.10.44
The Excess Burst Size is the maximum amount of uncommitted data in access of Bc that the network will attemp to deliver during a time interval (Tc). End stations are allowed to transmit data in excess of the committed burst rate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcsnaLvpTrParameters 2.1.866.20.1.32.1.20
OBJECT IDENTIFIER    

fcsnaLvpTrParamLinkType 2.1.866.20.1.32.1.20.1
frontal must be connected to the a primary link-station or negociable link-station that will become the primary, remote must be connected to the a decondary link-station or negociable link-station that will become the secondary
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER frontal(1), remote(2)  

fcsnaLvpTrParamBroadcastType 2.1.866.20.1.32.1.20.2
This field defines the type of broadcast test frame. The unit sends to a destination to determine the best route
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), all-routes(2), single-route(3)  

fcsnaLvpTrParamLocalTest 2.1.866.20.1.32.1.20.3
This feature is used in 'frontal' mode. If this feature is set to on, and when the internal connection is established, it will send a local test frame to the primary link-station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcsnaLvpTrParamCallDirection 2.1.866.20.1.32.1.20.4
Frontal mode is called. Remote mode is calling.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER called(1), calling(2)  

fcsnaLvpTrRingNo 2.1.866.20.1.32.1.20.5
This field identifies the ring number of the LAN to which the unit connects.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4095  

fcsnaLvpTrBridgeNo 2.1.866.20.1.32.1.20.6
A unit attached to a Token Ring LAN represents a bridge between the physical LAN ring and the network's virtual ring.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fcsnaLvpTrMacAddressTrans 2.1.866.20.1.32.1.20.7
MAC address translation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcsnaLvpTrParamT1 2.1.866.20.1.32.1.20.10
T1 Reply timer. A link-station uses T1 to detect a failure to receive a required acknowlegment or response. T1 runs when there are acknowlegments outstanding, it is reset when acknowlegments are received.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..25000  

fcsnaLvpTrParamN2 2.1.866.20.1.32.1.20.11
The maximum number of transmissions. If the reply timer expires for whatever reason, an S-frame with poll bit set is sent to sollicit a response from remote link-station. If there is still no response after N2 retry, the link is deemed to be inoperative.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fcsnaLvpTrParamT2 2.1.866.20.1.32.1.20.12
Receiver acknowledge timer. The end station uses this timer to delay the seding of an acknowlegment for a received I-frame LPDU. The link-station starts T2 when it receives an I-frame and resets it when it sends an acknowlegment. T2 must be less than T1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..15000  

fcsnaLvpTrParamN3 2.1.866.20.1.32.1.20.13
Number of I-frame LPDU's received before sending an acknowledgment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fcsnaLvpTrParamNW 2.1.866.20.1.32.1.20.14
Number of acknowledgments needed to increment Ww
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fcsnaLvpTrParamTW 2.1.866.20.1.32.1.20.15
LLC transmit window size. This is maximum number of sequentially numbered Iframe that the link-station may have outstanding at any given time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fcsnaLvpTrParamRW 2.1.866.20.1.32.1.20.16
LLC receive window size. This is the maximum number of unacknowlegment sequentially numbered I-frame the link-station can receive from the remote station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fcsnaLvpTrParamMinRecallTimer 2.1.866.20.1.32.1.20.20
Slow call timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..990  

fcsnaLvpTrParamSubscriberNumber 2.1.866.20.1.32.1.20.21
The value of this object is the SB number added to the DNICZO of the equipment to make the calling address in a call sent from this logical port. The value must contain 2 digits (digits 0..9). The default value is '22'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcsnaLvpTrParamReliableVc 2.1.866.20.1.32.1.20.22
The value of this object is used to enable the Reliable Virtual Circuit service. The authorized values are : off : no RVC, the VCs are considered as normal VCs, no particular processing, clear : RVCs are not allowed for the subscriber, each attempt to establish a RVC provokes a clear of the connection, subscribe : all calls transmitted by the subscriber establish RVCs, it is also possible to receive calls with RVC option, check : for a link to a subscriber : when a call with RVC option is received, a RVC is established for a link to a network : the RVC option is ignored when it is present in a call sent by a local subscriber, the connection is cleared when the RVC option is present in a call sent by the network. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), clear(3), subscribe(2), check(4)  

fcsnaLvpTrParamCompression 2.1.866.20.1.32.1.20.30
The value of this object indicates the compression enabling for each direction. The authorized values are : off : no compression, networkToSubscriber : compression of the flow from the remote peer to the equipment, subscriberToNetwork : compression of the flow from the equipment to the remote peer, bothway : compression of the two flows from and to the equipment. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), networkToSubscriber(2), subscriberToNetwork(3), bothway(4)  

fcsnaLvpTrParamCompressNegotiation 2.1.866.20.1.32.1.20.31
The value of this object indicates whether the compression facility is negociated or not and, if negociated, the optional/obligatory status. The authorized values are : off' :no negociation, onOptionalCompression : negociation but compression is optional, onMandatoryCompression : negociation and compression is mandatory. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onOptionalCompression(2), onMandatoryCompression(3)  

fcsnaLvpTrParamCompressScrambling 2.1.866.20.1.32.1.20.32
The value of this object indicates, when the compression is active, whether the scrambling is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcsnaLvpTrParamCompressMultiPacketsTimer 2.1.866.20.1.32.1.20.33
The value of this object defines the maximum waiting time, in milliseconds by steps of 100 milliseconds , which, if there is not another packet to compress, the packet of compressed packets is sent beyond (this permits to reduce the number of packets transmitted to the remote peer). The authorized values are '0..1500'. '0' means no packets grouping (i. e. : each packet is individually compressed and sent). The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

fcsnaLvpTrParamCos 2.1.866.20.1.32.1.20.40
Class Of Service VBR or UBR.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1)  

fcsnaLvpTrParamCir 2.1.866.20.1.32.1.20.41
Committed information Rate is the maximum number of bits per seconds which an end station can transmit into the network . This is the access rate of the user-network interface and it is limited by the line speed of the user-network connection and established by subscription.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 600..2048000  

fcsnaLvpTrParamCirMin 2.1.866.20.1.32.1.20.42
If the end station is informed about the congestion of the network, this is the minimum CIR that the end station can transmit into the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcsnaLvpTrParamBc 2.1.866.20.1.32.1.20.43
The Committed Burst Size is a measure for the volume of data for which the network will garantee message delivery under normal conditions. It is measured during the committed rate measurement interval (Tc).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcsnaLvpTrParamBe 2.1.866.20.1.32.1.20.44
The Excess Burst Size is the maximum amount of uncommitted data in access of Bc that the network will attemp to deliver during a time interval (Tc). End stations are allowed to transmit data in excess of the committed burst rate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcsnaGeneralParameters 2.1.866.20.1.32.5
OBJECT IDENTIFIER    

fcsnaGpRoutingTable 2.1.866.20.1.32.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcsnaGpRoutingEntry

fcsnaGpRoutingEntry 2.1.866.20.1.32.5.1.1
An entry of fcsnaGpRoutingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcsnaGpRoutingEntry  

fcsnaGpRoutClusterPuId 2.1.866.20.1.32.5.1.1.1
PU id cluster
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

fcsnaGpRoutHostPuId 2.1.866.20.1.32.5.1.1.2
PU id host
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1000..1999  

fcsnaGpRoutStatus 2.1.866.20.1.32.5.1.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcsnaGpRoutDsap 2.1.866.20.1.32.5.1.1.10
DSAP This field defines the service access point for the PU session. The unit uses this Address in conjunction withe the MAC address to to map the session to its destination. If the PU originates the call, this is the source SSAP. If the PU responds the call, this is The destionation DSAP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcsnaGpRoutSsap 2.1.866.20.1.32.5.1.1.11
SSAP This field defines the service access point for the PU session. The unit uses this Address in conjunction withe the MAC address to to map the session to its destination. If the PU originates the call, this is the source SSAP. If the PU responds the call, this is The destionation DSAP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcsnaGpRoutCos 2.1.866.20.1.32.5.1.1.20
COS Class Of Service VBR or UBR
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ubr(3), vbr(1), vbr-rt(2)  

fcsnaGpRoutCir 2.1.866.20.1.32.5.1.1.21
CIR Committed information Rate is the maximum number of bits per seconds which an end station can transmit into the network . This is the access rate of the user-network interface and it is limited by the line speed of the user-network connection and established by subscription.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcsnaGpRoutCirmin 2.1.866.20.1.32.5.1.1.22
CIRmin If the end station is informed about the congestion of the network, this is the minimum CIR that the end station can transmit into the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcsnaGpRoutBc 2.1.866.20.1.32.5.1.1.23
Bc The Committed Burst Size is a measure for the volume of data for which the network will garantee message delivery under normal conditions. It is measured during the committed rate measurement interval (Tc)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcsnaGpRoutBe 2.1.866.20.1.32.5.1.1.24
Be The Excess Burst Size is the maximum amount of uncommitted data in access of Bc that the network will attemp to deliver during a time interval (Tc). End stations are allowed to transmit data in excess of the committed burst rate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

fcsnaGpRemotePuTable 2.1.866.20.1.32.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcsnaGpRemotePuEntry

fcsnaGpRemotePuEntry 2.1.866.20.1.32.5.2.1
An entry of fcsnaGpRemotePuTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcsnaGpRemotePuEntry  

fcsnaGpRemPuPuId 2.1.866.20.1.32.5.2.1.1
Physical Unit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1999  

fcsnaGpRemPuStatus 2.1.866.20.1.32.5.2.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcsnaGpRemPuProtocol 2.1.866.20.1.32.5.2.1.3
Type de protocole The value of this object allows to interworking with an remote Equipement which uses another communication protocole as X25/QLLC, SDLC or Lan protocol SNA/LLC2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), x25(2), sdlc(3), frban(4), sna-ethernet(5)  

fcsnaGpSdlcTable 2.1.866.20.1.32.5.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcsnaGpSdlcEntry

fcsnaGpSdlcEntry 2.1.866.20.1.32.5.3.1
An entry of fcsnaGpSdlcTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcsnaGpSdlcEntry  

fcsnaGpSdlcPuId 2.1.866.20.1.32.5.3.1.1
Physical Unit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1999  

fcsnaGpSdlcStatus 2.1.866.20.1.32.5.3.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcsnaGpSdlcLp 2.1.866.20.1.32.5.3.1.3
Logical Port The value of this object identifies one and only one SDLC logical port. The possible values are : '0..131'. If it is unused, the value of this parameter is '255'. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..181  

fcsnaGpSdlcCluster 2.1.866.20.1.32.5.3.1.4
Cluster This is the address of the PU of the controller.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

fcsnaGpX25Table 2.1.866.20.1.32.5.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcsnaGpX25Entry

fcsnaGpX25Entry 2.1.866.20.1.32.5.4.1
An entry of fcsnaGpX25Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcsnaGpX25Entry  

fcsnaGpX25PuId 2.1.866.20.1.32.5.4.1.1
Physical Unit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1999  

fcsnaGpX25Status 2.1.866.20.1.32.5.4.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcsnaGpX25Address 2.1.866.20.1.32.5.4.1.3
Adresse X121 Called X121 address. X121 Address of the corresponding Hpad element
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcsnaGpLanFrTable 2.1.866.20.1.32.5.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcsnaGpLanFrEntry

fcsnaGpLanFrEntry 2.1.866.20.1.32.5.5.1
An entry of fcsnaGpLanFrTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcsnaGpLanFrEntry  

fcsnaGpLanFrPuId 2.1.866.20.1.32.5.5.1.1
Physical Unit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1999  

fcsnaGpLanFrStatus 2.1.866.20.1.32.5.5.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcsnaGpLanFrMacAddress 2.1.866.20.1.32.5.5.1.3
Adresse MAC This parameter defines the PU MAC address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

fcsnaGpMiscellaneousParameters 2.1.866.20.1.32.5.10
OBJECT IDENTIFIER    

fcsnaGpMiscMacAddrLearningMode 2.1.866.20.1.32.5.10.1
The value of this object indicates whether automatic MAc address learning is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcBridge 2.1.866.20.1.35
OBJECT IDENTIFIER    

fcbBridging 2.1.866.20.1.35.1
The value of this object indicates whether the bridge forwards data or not, and if it does whether the Spanning Tree Protocol (STP) is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), transparentBridge(2), transparentBridgeStp(3)  

fcbBridgingBetweenRemoteVp 2.1.866.20.1.35.2
The value of this object indicates whether the bridge forwards data between remote virtual ports or not. Disabling this possibility prevents from making a way between remote equipments on different virtual networks which should not exchange data. BRIDGING BETWEEN REMOTE VP IS NOT IMPLEMENTED IN THIS SOFTWARE VERSION. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcbTransparentBridge 2.1.866.20.1.35.10
OBJECT IDENTIFIER    

fcbBrdgVirtualPortTable 2.1.866.20.1.35.10.1
This table defines the virtual ports used by the bridge. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fcbBrdgVpStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcbBrdgVirtualPortEntry

fcbBrdgVirtualPortEntry 2.1.866.20.1.35.10.1.1
An entry of fcbBrdgVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcbBrdgVirtualPortEntry  

fcbBrdgVpVirtualPortId 2.1.866.20.1.35.10.1.1.1
The value of this object identifies one and only one virtual port. This virtual port must exist in fcvVirtualPortTable. This is a decimal integer in the range 0 to 11.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fcbBrdgVpStatus 2.1.866.20.1.35.10.1.1.2
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcbBrdgVpAgingTime 2.1.866.20.1.35.10.1.1.4
The value of this object is the aging time in seconds for addresses learnt on this virtual port. This is a decimal integer in the range 0 to 3600. The default value is '300'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

fcbBrdgVpBroadcasting 2.1.866.20.1.35.10.1.1.5
The value of this object indicates whether broadcasting is enabled or not for this virtual port. This function may permit to limit the use of expansive WAN links. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcbBrdgVpFcsPreservation 2.1.866.20.1.35.10.1.1.6
The value of this object indicates whether the FCS (Frame Check Sequence) of MAC frames is transported over the WAN network or not through this virtual port. This value is meaningless for local virtual ports. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), offTinygram(3), on(2)  

fcbBrdgRemoteAddressMappingTable 2.1.866.20.1.35.10.2
This table contains the static entries of the address translation table. The transparent Bridge function learns dynamically the entries of the address translation table. Owing to speed considerations or the possibility of learning, it may be necessary to create static entries in this table. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fcbBrdgMapStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcbBrdgRemoteAddressMappingEntry

fcbBrdgRemoteAddressMappingEntry 2.1.866.20.1.35.10.2.1
An entry of fcbBrdgRemoteAddressMappingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcbBrdgRemoteAddressMappingEntry  

fcbBrdgMapMacAddress 2.1.866.20.1.35.10.2.1.1
The value of this object is the MAC address of a remote station to be reached through WAN networks. This is a six-bytes octet string with 12 digits in the range 0 to F. Broadcasting (FF FF FF FF FF FF), null (00 00 00 00 00 00) and group (bit 0 of first byte equal to 1) addresses must not be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

fcbBrdgMapStatus 2.1.866.20.1.35.10.2.1.2
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcbBrdgMapRemoteAddress 2.1.866.20.1.35.10.2.1.3
The value of this object is the X121 address of a remote bridge able to reach this remote station. This address must exist in fcvRvpConnectionTable. This is a eight-bytes octet string with : up to 15 digits in the range 0 to 9, mandatory 'F' digits to pad the value until a total of 16 digits (the equipment configurator does not need this final padding). The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcbSpanningTreeProtocol 2.1.866.20.1.35.20
OBJECT IDENTIFIER    

fcbStpPriority 2.1.866.20.1.35.20.1
The value of this object is the Bridge Priority used in association with the MAC address of the Ethernet port by the STP algorithm so as to determine from among all the possibilities, the bridge that will be elected as topology root. The lower the value, the higher the bridge priority.. This is a decimal integer in the range 0 to 65535. The default value is '32768'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fcbStpMaxAge 2.1.866.20.1.35.20.2
The value of this object is the maximum age, in milliseconds, of STP information learned from the network on any virtual port before it is discarded. This value is used by all bridges when this bridge is acting as the root of the spanning tree. This maximum age is the life duration assigned to a Configuration bridge PDU issued at the initiative of the bridge. This life duration will be decremented by the various bridges crossed and will reach zero, causing the deletion of the Configuration bridge PDU. This is a decimal integer in the range 600 to 4000. The default value is '2000'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 600..4000  

fcbStpHelloTime 2.1.866.20.1.35.20.3
The value of this object is the hello time, in milliseconds. This is the amount of time between the transmissions of Configuration bridge PDUs by this node on any virtual port when it is the root of the spanning tree or trying to become so. This value is used by all bridges when this bridge is acting as the root. This is a decimal integer in the range 100 to 1000. The default value is '200'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..1000  

fcbStpForwardDelay 2.1.866.20.1.35.20.4
The value of this object is the forward delay, in milliseconds. This time value controls how fast a virtual port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. This value is the value that this bridge and all others would start using if/when this bridge were to become the root. The Forward Delay value corresponds to the time during which the bridge that has just been started does not provide its service; it waits until the STP has established its topology. During this period, only the Configuration bridge PDUs are bridged, the user frames are not processed and this time delay is also used as minimum duration of a bridge state. This is a decimal integer in the range 400 to 3000. The default value is '1500'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 400..3000  

fcbStpVirtualPortTable 2.1.866.20.1.35.20.10
This table defines the Spanning Tree Protocol parameters of virtual ports. It is not possible to add or delete an entry of this table (each entry corresponds, in fcbBrdgVirtualPortTable, to one instance of fcbBrdgVpVirtualPortId).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcbStpVirtualPortEntry

fcbStpVirtualPortEntry 2.1.866.20.1.35.20.10.1
An entry of fcbStpVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcbStpVirtualPortEntry  

fcbStpVpVirtualPortId 2.1.866.20.1.35.20.10.1.1
The value of this object identifies one and only one virtual port. Each virtual port corresponds, in fcbBrdgVirtualPortTable, to one instance of fcbBrdgVpVirtualPortId. This is a decimal integer in the range 0 to 11.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fcbStpVpPortPriority 2.1.866.20.1.35.20.10.1.2
The value of this object is the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of fcbStpVpVirtualPortId. The port priority is used with its extra cost and its MAC address for the STP algorithm in order to grade the ports of the bridge in order of preference. This concept is used by the STP algorithm to elect the root port and to detect a loop so as to determine the port to be cut off. This is a decimal integer in the range 0 to 255. The default value is '128'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fcbStpVpPortPathCost 2.1.866.20.1.35.20.10.1.3
The value of this object is the contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached virtual network. The path cost of the port is used jointly with its priority and its MAC address by the STP algorithm in order to classify the bridge ports in order of preference. Thge lower the cost, the better preferred is the port. This concept is used by the STP algorithm on initialization to elect the root port and when a loop is detected in order to determine which port is to be cut off. This is a decimal integer in the range 1 to 65535. The default value is '100'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

fcbStpVpBpduEncapsulation 2.1.866.20.1.35.20.10.1.4
The value of this object indicates, for the remote virtual ports, how the STP frames are encapsulated on the WAN virtual network. This value is meaningless for local virtual ports : mac : STP frames are encapsulated in SNAP 802.3, bpdu : STP frames are encapsulated in SNAP BPDU. The default value is 'mac'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mac(1), bpdu(2)  

fcIpRouter 2.1.866.20.1.36
OBJECT IDENTIFIER    

fciIpRouting 2.1.866.20.1.36.1
The value of this object indicates whether the equipment is acting as an IP gateway in respect to the forwarding of IP datagrams received by, but not addressed to, this entity. IP gateways forward IP datagrams. IP hosts do not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciFastIpRouting 2.1.866.20.1.36.2
The value of this object indicates whether the optimized forwarding of IP datagrams is enabled or not. This optimization consist in reducing the validity checks carried out on each IP datagram. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciIcmpRedirection 2.1.866.20.1.36.3
The value of this object indicates whether the ICMP (Internet Control Message Protocol) Redirect messages are sent or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciSourceRouting 2.1.866.20.1.36.4
The value of this object indicates whether the Source Routing information is inserted in the forwarded IP datagrams or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciVirtualPortTable 2.1.866.20.1.36.10
This table defines the virtual ports used by the IP router. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fciVpStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciVirtualPortEntry

fciVirtualPortEntry 2.1.866.20.1.36.10.1
An entry of fciVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciVirtualPortEntry  

fciVpVirtualPortId 2.1.866.20.1.36.10.1.1
The value of this object identifies one and only one virtual port. This virtual port must exist in fcvVirtualPortTable. This is a decimal integer in the range 0 to 11.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fciVpStatus 2.1.866.20.1.36.10.1.2
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciVpIpAddress 2.1.866.20.1.36.10.1.3
The value of this object is the IP address associated with this virtual port. This IP address must be a valid host address. The default value is '0.0.0.0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciVpNetMask 2.1.866.20.1.36.10.1.4
The value of this object is the subnet mask associated with the IP address of this virtual port. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0. In the absence of subnets, the mask contains 255.0.0.0 for an address of class A, 255.255.0.0 for class B, 255.255.255.0 for class C. The default value is '255.255.255.0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciVpMtu 2.1.866.20.1.36.10.1.5
The value of this object defines, in octets, the largest IP datagram (Maximum Transmit Unit) which can be sent/received on this virtual port. This is a decimal integer in the range 576 to 9180. The default value is '1500'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 576..9180  

fciVpProxyArp 2.1.866.20.1.36.10.1.6
The value of this object indicates whether the proxy-ARP processing is enabled or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciVpInverseArp 2.1.866.20.1.36.10.1.7
For all connections without IP address association on an IP VP, this parameter activate an InverseARP resolution. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciLocalVirtualPortTable 2.1.866.20.1.36.11
This table defines the local virtual ports used by the IP router. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fciLvpStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciLocalVirtualPortEntry

fciLocalVirtualPortEntry 2.1.866.20.1.36.11.1
An entry of fciLocalVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciLocalVirtualPortEntry  

fciLvpVirtualPortId 2.1.866.20.1.36.11.1.1
The value of this object identifies one and only one local virtual port. This local virtual port must exist in fciVirtualPortTable and in fcvLocalVirtualPortTable. This is a decimal integer in the range 0 to 11.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fciLvpStatus 2.1.866.20.1.36.11.1.2
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciLvpEncapsulation 2.1.866.20.1.36.11.1.3
The value of this object indicates, for this local virtual ports, how the IP datagrams are encapsulated on the LAN virtual network : ethernet : IP datagrams are encapsulated according to Ethernet V2 standard, ieee802-3 : IP datagrams are encapsulated according to IEEE 802.3 standard. The default value is 'ethernet'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ethernet(1), ieee802-3(2), monoRing(3), multiArb(4), multiSrb(5)  

fciLocalClusterTable 2.1.866.20.1.36.12
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciLocalClusterEntry

fciLocalClusterEntry 2.1.866.20.1.36.12.1
An entry of fciLocalClusterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciLocalClusterEntry  

fciLclVirtualPortId 2.1.866.20.1.36.12.1.1
VP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fciLclClusterNumber 2.1.866.20.1.36.12.1.2
Cluster number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fciLclStatus 2.1.866.20.1.36.12.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciLclVirtualIpAddress 2.1.866.20.1.36.12.1.4
Virtual IP Address
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciLclPriority 2.1.866.20.1.36.12.1.5
Priority
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciRemoteNetToMediaTable 2.1.866.20.1.36.15
This table contains the IP address translations used for mapping from IP address to X121 address for each IP router reachable through a WAN virtual network. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fciRemStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciRemoteNetToMediaEntry

fciRemoteNetToMediaEntry 2.1.866.20.1.36.15.1
An entry of fciRemoteNetToMediaTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciRemoteNetToMediaEntry  

fciRemIpAddress 2.1.866.20.1.36.15.1.1
The value of this object is the IP address of one IP router reachable through a WAN virtual network. This IP address must be a valid host address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciRemStatus 2.1.866.20.1.36.15.1.2
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciRemRemoteAddress 2.1.866.20.1.36.15.1.3
The value of this object is the X121 address of the called remote IP router. This address must exist in fcvRvpConnectionTable. This is a eight-bytes octet string with : up to 15 digits in the range 0 to 9, mandatory 'F' digits to pad the value until a total of 16 digits (the equipment configurator does not need this final padding). The default value is 'FF FF FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fciNetToMediaTable 2.1.866.20.1.36.16
ARP (Address Resolution Protocol) is in charge to dynamically manage the IP address translations used for mapping from IP address to MAC address for each IP host or IP router reachable through a LAN. This table contains translations which are statically added to the dynamic ones. Set any writable object(s) of this table to valid value(s) with a new index value to create an entry (the objects of the entry not present in this SET REQUEST will take their default values). Set fciNetToMediaStatus to 'invalid' to delete an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciNetToMediaEntry

fciNetToMediaEntry 2.1.866.20.1.36.16.1
An entry of fciNetToMediaTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciNetToMediaEntry  

fciNetToMediaIpAddress 2.1.866.20.1.36.16.1.1
The value of this object is the IP address of one IP host or IP router reachable through a LAN virtual network. This IP address must be a valid host address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciNetToMediaStatus 2.1.866.20.1.36.16.1.2
The value of this object indicates the state of the entry of this table. It must be set to 'invalid' to delete the entry. The default value is 'valid'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciNetToMediaMacAddress 2.1.866.20.1.36.16.1.3
The value of this object is the MAC address of this IP host or IP router. This is a six-bytes octet string with 12 digits in the range 0 to F. Broadcasting (FF FF FF FF FF FF), null (00 00 00 00 00 00) and group (bit 0 of first byte equal to 1) addresses must not be used. The default value is 'FF FF FF FF FF FF' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

fciIpRouteTable 2.1.866.20.1.36.20
RIP (Routing Information Protocol) or EGP (External Gateway Protocol) are in charge to dynamically manage the routes used by the IP router. This table contains routes which are statically added to the dynamic ones.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciIpRouteEntry

fciIpRouteEntry 2.1.866.20.1.36.20.1
An entry of fciIpRouteTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciIpRouteEntry  

fciRouteDest 2.1.866.20.1.36.20.1.1
The value of this object is the destination IP address of this route. An entry with a value of 0.0.0.0 is considered a default route. This IP address may be a network address (hosts bits set to 0) or a host address (at least one hosts bit set to 1). The default value is '0.0.0.0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciRouteMask 2.1.866.20.1.36.20.1.2
The value of this object is the subnet mask associated with the IP address of this virtual port. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0. In the absence of subnets, the mask contains 255.0.0.0 for an address of class A, 255.255.0.0 for class B, 255.255.255.0 for class C. If the value of fciRouteDest is 0.0.0.0 (a default route), then the mask value is also 0.0.0.0. The default value is '255.255.255.0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciRouteStatus 2.1.866.20.1.36.20.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciRouteNextHop 2.1.866.20.1.36.20.1.4
The value of this object is the IP address of the next hop of this route. This IP address must be a valid host address. The default value is '0.0.0.0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciRouteMetric 2.1.866.20.1.36.20.1.5
The value of this object is the routing metric for this route. The search algorithm is based on metrics for choosing between several possible routes to reach the destination of an IP datagram. In the case of RIP, the metrics indicates the number of IP routers through which an IP datagram must pass to reach its destination. The algorithm chooses preferably the shortest metric route. The authorized values are '1..15'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fciFlowManagement 2.1.866.20.1.36.30
OBJECT IDENTIFIER    

fciFlowTable 2.1.866.20.1.36.30.1
This table defines the flows. A flow is a selection of IP datagrams coming from a local virtual port (i.e., froma a LAN).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciFlowEntry

fciFlowEntry 2.1.866.20.1.36.30.1.1
An entry of fciFlowTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciFlowEntry  

fciFlowFlowId 2.1.866.20.1.36.30.1.1.1
The value of this object identifies one and only one flow. A flow is a selection of IP datagrams coming from a local virtual port (i.e., froma a LAN). Several flows may belong to the same family. This flow uses a combination of several conditions defined below. A flow selects the received IP datagrams which simultaneously verify those of the conditions which are meaningful for this flow. When several flows are defined for the same VP with overlapping conditions, the IP datagram belongs to the first (in increasing order of flow identifiers) of all the flows that select it. So the numbering order must be done with a particular attention. By convention, if none of the conditions of this entry is meaningful, then every IP datagram is selected (default flow). The authorized values are '0..199'. If it is unused, the value is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fciFlowStatus 2.1.866.20.1.36.30.1.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciFlowType 2.1.866.20.1.36.30.1.1.3
The value of this object indicates the family to which belong any IP datagram selected by the conditions defining this flow. Several flows may belong to the same family. The transmission of the family of IP datagrams over WAN virtual networks is defined by fcvRvpConnFlowTypeMask. By convention, the family 0 groups together all the IP datagrams that the router has to reject (filtering at the IP level) whereas the filtering described in fcvLvpFltFilteringTable concerns all the traffic received on one of the IP, IPX or CNLP routers or bridge. The authorized values are : 0, 1, 2, 4, 8, 16, 32, 64 and 128. The default value is '255'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciFlowVpId 2.1.866.20.1.36.30.1.1.5
The value of this object specifies the virtual port for which the flow is defined. Any IP datagram received on this VP will go through the evaluations of the meaningful conditions defined for this flow and it is selected if all these comparisons produce positive results.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..11  

fciFlowSrcIpAddress 2.1.866.20.1.36.30.1.1.10
The value of this object specifies the value with which the source IP address field of all the IP datagrams received on this VP is compared. If the bits, selected by fciFlowSrcMask, from this value are equal to the same bits from the source IP address of a IP datagram then this IP datagram is selected. This condition on source IP address is meaningless if fciFlowSrcMask is equal to '0.0.0.0' (no bits selected). The authorized values are all four bytes integer with an IP address notation but this value is not necessarily a valid IP address (e.g. 0.0.0.41 or 255.0.0.0). The default value is '0.0.0.0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciFlowSrcMask 2.1.866.20.1.36.30.1.1.11
The value of this object specifies the bits from fciFlowSrcIpAddress which are to be compared with the same bits from the source IP address field of all the IP datagrams received on this VP. This condition on source IP address is meaningless if this mask is equal to '0.0.0.0' (no bits selected). The authorized values are all four bytes integer with an IP address notation but this value is not necessarily a valid IP address mask (e.g., 0,0,0,127 or 0,255,0,0). The default value is '0.0.0.0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciFlowDestIpAddress 2.1.866.20.1.36.30.1.1.12
The value of this object specifies the value with which the destination IP address field of all the IP datagrams received on this VP is compared. If the bits, selected by fciFlowDestMask, from this value are equal to the same bits from the destination IP address of a IP datagram then this IP datagram is selected. This condition on destination IP address is meaningless if fciFlowDestMask is equal to '0.0.0.0' (no bits selected). The authorized values are all four bytes integer with an IP address notation but this value is not necessarily a valid IP address (e.g. 0.0.0.41 or 255.0.0.0). The default value is '0.0.0.0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciFlowDestMask 2.1.866.20.1.36.30.1.1.13
The value of this object specifies the bits from fciFlowDestIpAddress which are to be compared with the same bits from the destination IP address field of all the IP datagrams received on this VP. This condition on destination IP address is meaningless if this mask is equal to '0.0.0.0' (no bits selected). The authorized values are all four bytes integer with an IP address notation but this value is not necessarily a valid IP address mask (e.g., 0,0,0,127 or 0,255,0,0). The default value is '0.0.0.0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciFlowProtocol 2.1.866.20.1.36.30.1.1.14
The value of this object specifies the value with which the protocol field of all the IP datagrams received on this VP is compared. If these two values are equal then the IP datagram is selected. This field identifies the protocol transported by IP (see PROTOCOL NUMBERS in RFC 1700). E.g. 1 = ICMP, 6 = TCP, 8 = EGP, 17 = UDP ... This condition on protocol is meaningless if this value is equal to '0'. The authorized values are '0..255'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciFlowPortMin 2.1.866.20.1.36.30.1.1.15
The value of this object specifies the minimum value with which the source port and destination port fields of all the TCP/IP or UDP/IP datagrams received on this VP are compared. When fciFlowPortMax > fciFlowPortMin > 0, if the value of at least one of the two fields from the IP datagram is included inside these limits then the IP datagram is selected. When fciFlowPortMax > 0 and fciFlowPortMin = 0, if the value of at least one of the two fields from the IP datagram is equal to fciFlowPortMax then the IP datagram is selected. When fciFlowPortMax = 0 and fciFlowPortMin > 0, if the value of at least one of the two fields from the IP datagram is equal to fciFlowPortMin then the IP datagram is selected. When fciFlowPortMax = fciFlowPortMin = 0, this condition on ports is meaningless. Examples : (see WELL KNOWN PORT NUMBERS in RFC 1700); 21 = ftp, 23 = telnet, 67 = bootp server, 68 = bootp client, 69 = ttfp, 161 = snmp, 162 = snmptrap. The authorized values are '0..65535'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fciFlowPortMax 2.1.866.20.1.36.30.1.1.16
The value of this object specifies the maximum value with which the source port and destination port fields of all the TCP/IP or UDP/IP datagrams received on this VP are compared. When fciFlowPortMax > fciFlowPortMin > 0, if the value of at least one of the two fields from the IP datagram is included inside these limits then the IP datagram is selected. When fciFlowPortMax > 0 and fciFlowPortMin = 0, if the value of at least one of the two fields from the IP datagram is equal to fciFlowPortMax then the IP datagram is selected. When fciFlowPortMax = 0 and fciFlowPortMin > 0, if the value of at least one of the two fields from the IP datagram is equal to fciFlowPortMin then the IP datagram is selected. When fciFlowPortMax = fciFlowPortMin = 0, this condition on ports is meaningless. Examples : (see WELL KNOWN PORT NUMBERS in RFC 1700); 21 = ftp, 23 = telnet, 67 = bootp server, 68 = bootp client, 69 = ttfp, 161 = snmp, 162 = snmptrap. The authorized values are '0..65535'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fciFlowLengthMax 2.1.866.20.1.36.30.1.1.17
The value of this object specifies the value with which the length of all the IP datagrams received on this VP are compared. If the number of octets in the IP datagram is less or equal to this value then the IP datagram is selected. This condition on length is meaningless if this value is equal to '0'. The authorized values are '0..65535'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fciFlowSegmented 2.1.866.20.1.36.30.1.1.18
The value of this object specifies the selection of segmented IP datagrams received on this VP : notChecked : This condition on segmentation is meaningless. no : The IP datagrams not segmented are selected. yes : The IP datagrams segmented are selected. The default value is 'notChecked'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notChecked(1), no(2), yes(3)  

fciFlowAddrSubstituteTable 2.1.866.20.1.36.30.2
This table is used for replacing the IP destination address contained in every IP datagram belonging to a specific flow by a precise IP address. This substitution takes place before the frame is examined by the IP routing. Therefore, it is possible, for instance, to orient the IP/UDP traffic distributed towards a specific recipient..
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciFlowAddrSubstituteEntry

fciFlowAddrSubstituteEntry 2.1.866.20.1.36.30.2.1
An entry of fciFlowAddrSubstituteTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciFlowAddrSubstituteEntry  

fciFlowSubstFlowId 2.1.866.20.1.36.30.2.1.1
The value of this object identifies one and only one flow. A flow is a selection of IP datagrams coming from a local virtual port (i.e., froma a LAN). It must exist in fciFlowTable. The authorized values are '0..199'. If it is unused, the value is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fciFlowSubstDestIpAddress 2.1.866.20.1.36.30.2.1.2
The value of this object is the new destination IP address which replaces the existing one in all IP datagrams belonging to this flow. This IP address must be a broadcasting IP address (hosts bits set to 1) or a host address (at least one hosts bit set to 1). The default value is '0.0.0.0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciFlowSubstStatus 2.1.866.20.1.36.30.2.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciFlowRouteTable 2.1.866.20.1.36.30.20
This table contains routes which are statically defined for particular flows (this permits to bypass the normal IP routing process).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciFlowRouteEntry

fciFlowRouteEntry 2.1.866.20.1.36.30.20.1
An entry of fciFlowRouteTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciFlowRouteEntry  

fciFlowRouteFlowId 2.1.866.20.1.36.30.20.1.1
The value of this object identifies one and only one flow. A flow is a selection of IP datagrams coming from a local virtual port (i.e., froma a LAN). It must exist in fciFlowTable. The authorized values are '0..199'. If it is unused, the value is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fciFlowRouteStatus 2.1.866.20.1.36.30.20.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciFlowRouteNextHop 2.1.866.20.1.36.30.20.1.3
The value of this object is the IP address of the next hop of the route used by this flow. This IP address must be a valid host address. The default value is '0.0.0.0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciRip 2.1.866.20.1.36.40
OBJECT IDENTIFIER    

fciRipAdminStatus 2.1.866.20.1.36.40.1
The value of this object indicates whether RIP (Routing Information Protocol) is enabled or not : off : RIP is not enabled, on : RIP is enabled in 'active mode (it learns the routes transmitted by the adjacents routers to complete the routing table and itself distributes all or part of the routes contained in the routing table), quiet : RIP is enabled in 'passive mode (it learns the routes transmitted by the adjacents routers to complete the routing table but itself does not distribute anything). The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), quiet(3)  

fciRipStaticRoutesDistribution 2.1.866.20.1.36.40.2
The value of this object indicates whether RIP distributes static entries of the routing table (i.e., those defined in fciIpRouteTable) or not. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciRipEgpRoutesDistribution 2.1.866.20.1.36.40.3
The value of this object indicates whether RIP distributes entries of the routing table learnt by EGP (Exterior Gateway Protocol) or not. The autonomous systems from which these routing informations are distributed are defined in fciRipEgpRoutesDistributionTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciRipDistributionTimer 2.1.866.20.1.36.40.4
The value of this object indicates the waiting time in seconds between two successive transmissions of informations from the routing table by RIP. The authorized values are '30..3600'. The default value is '30'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 30..3600  

fciRipPreference 2.1.866.20.1.36.40.5
The value of this object controls preference for routes learned (imported) by RIP, relative to routes to same destination learned by others protocols. '0' is high preference. '255' is low preference.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciRipOspfRoutesDistribution 2.1.866.20.1.36.40.6
The value of this object indicates whether RIP distributes entries of the routing table learnt by OSPF (Open Shortest Path First) protocol or not. The metric used is specified by the field fciRipOspfRoutesDistributionMetric.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciRipOspfRoutesDistributionMetric 2.1.866.20.1.36.40.7
The value of this object indicates the metric used by RIP when propagating (exporting) routes learnt via OSPF.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

fciRipStaticRoutesDistributionMetric 2.1.866.20.1.36.40.8
The value of this object indicates the metric used by RIP when propagating (exporting) static routes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

fciRipVirtualPortTable 2.1.866.20.1.36.40.10
This table defines the RIP parameters of virtual ports. This table is meaningless if there is at least one entry in fciRipNeighborTable (in this case RIP learns [and/or sends] routing informations only from [and/or to] the neighbors defined in that table).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciRipVirtualPortEntry

fciRipVirtualPortEntry 2.1.866.20.1.36.40.10.1
An entry of fciRipVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciRipVirtualPortEntry  

fciRipVpVirtualPortId 2.1.866.20.1.36.40.10.1.1
The value of this object identifies one and only one virtual port. The authorized values are '0..199'. If it is unused, the value is '255'. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fciRipVpDistribution 2.1.866.20.1.36.40.10.1.2
The value of this object indicates whether performs its information exchanges on the IP network attached to this virtual port or not. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciRipVpMetricOut 2.1.866.20.1.36.40.10.1.3
The RIP output metric of this interface. This metric will be added to routes that are send via the interface. This parameter can be used to make other routers prefer other sources of RIP routes over this router.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

fciRipVpRipIn 2.1.866.20.1.36.40.10.1.4
The RIP input interface's administrative status. The value 'on' denotes that RIP packets received on this interface will be accepted. The value 'off' denotes that no RIP received packets will be accepted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciRipVpMetricIn 2.1.866.20.1.36.40.10.1.5
The RIP input metric of this interface. This metric will be added to incoming routes before they are installed in the routing table. This parameter can be used to make this router prefer RIP routes learned via the specified interface less than RIP routes from other interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

fciRipVpVersion 2.1.866.20.1.36.40.10.1.6
The RIP output packets version. The value of this object indicates the version of RIP packets sent on the interface. The value 'ripVersion1' implies sending RIP updates compliant with RFC 1058. 'ripVersion2' implies sending RIP updates compliant with RFC 1388.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ripVersion1(1), ripVersion2(2)  

fciRipVpMulticast 2.1.866.20.1.36.40.10.1.7
The RIP-2 multicast output interface's administrative status. The value 'on' implies sending RIP updates using the multicast capability.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), other(3)  

fciRipVpAuthType 2.1.866.20.1.36.40.10.1.8
Type of authentication shema used on the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAuthentication(1), simplePassword(2), other(3)  

fciRipVpAuthKey 2.1.866.20.1.36.40.10.1.9
The value to be used as the Authentication Key whenever the corresponding instance of fciRipVpAuthType has the value simplePassword. A modification of the corresponding instance of fciRipVpAuthType does not modify the fciRipVpAuthKey value. If a string shorter than 16 octets is supplied, it will be left-justified and padded to 16 octets, on the right, with nulls (0x00). Reading this object always results in an OCTET STRING of length zero; authentication may not be bypassed by reading the MIB object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciRipNeighborTable 2.1.866.20.1.36.40.20
This table defines the neighbors (i.e., the adjacent routers with RIP enabled) with witch RIP exchange routing informations. If this table is empty RIP uses fciRipVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciRipNeighborEntry

fciRipNeighborEntry 2.1.866.20.1.36.40.20.1
An entry of fciRipNeighborTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciRipNeighborEntry  

fciRipNeighborIpAddress 2.1.866.20.1.36.40.20.1.1
The value of this object is the IP address of a neighbor (i.e., an adjacent router with RIP enabled). This IP address must be a valid host address. The default value is '0.0.0.0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciRipNeighborStatus 2.1.866.20.1.36.40.20.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciRipNeighborOutput 2.1.866.20.1.36.40.20.1.3
This flag indicates whether the neighbor is a gateway to which RIP will send RIP packets (value : on or on V1 ) or not (value : off ). If the value is bck or bck V1 , RIP will send packets only if all members of the RIP backup group are down. The value on or bck force RIP to send RIP V2 packets if the RIP output packets version on that VP is RIP V2, or to send RIP V1 packets if the RIP output packets version on that VP is RIP V1. The value on V1 or bck V1 , is used when the neighbor doesn't support RIP V2, that value force RIP to send RIP V1 compatible packets compliant with RFC 1388.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), bck(3), on1(4), bk1(5)  

fciRipNeighborInput 2.1.866.20.1.36.40.20.1.4
This flag indicates whether the neighbor is a gateway from which RIP will accept RIP packets or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciRipNeighborBackupGroup 2.1.866.20.1.36.40.20.1.5
This flag indicates the RIP backup group number of the neighbor. If the neighbor doesn't belong to a group, the value is 255 (default value).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fciRipEgpRoutesDistributionTable 2.1.866.20.1.36.40.30
As defined by fciRipEgpRoutesDistribution, when RIP distributes entries of the routing table learnt by EGP (Exterior Gateway Protocol), this table defines which of these entries are to be distributed. Only entries learnt from a router of an automous system specified in this table are distributed by RIP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciRipEgpRoutesDistributionEntry

fciRipEgpRoutesDistributionEntry 2.1.866.20.1.36.40.30.1
An entry of fciRipEgpRoutesDistributionTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciRipEgpRoutesDistributionEntry  

fciRipEgpRoutesAsNumber 2.1.866.20.1.36.40.30.1.1
The value of this object identifies an autonomous system containing routers delivering the routing information that RIP distributes. This AS must exist in fciEgpNeighborTable. The authorized values are '1..65534'. The default value is '0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65534  

fciRipEgpRoutesStatus 2.1.866.20.1.36.40.30.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciRipEgpRoutesMetric 2.1.866.20.1.36.40.30.1.3
The value of this object is the value indicated in the transmitted RIP datagrams concerning routing information learnt by EGP and coming from this autonomous system. The authorized values are '1..15'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

fciOspf 2.1.866.20.1.36.41
OBJECT IDENTIFIER    

fciOspfGeneralParameters 2.1.866.20.1.36.41.1
OBJECT IDENTIFIER    

fciOspfAdminStatus 2.1.866.20.1.36.41.1.1
OSPF administrative status. The administrative status of OSPF in the router. The value 'on' denotes that the OSPF Process is active on at least one interface ; 'off' disables OSPF on all interfaces.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciOspfRouterId 2.1.866.20.1.36.41.1.2
OSPF router Id. A 32-bit integer uniquely identifying the router in the autonomous system. By convention, to ensure uniqueness, this should default to the value of one of the router's IP interface addresses.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciOspfRoutesPreference 2.1.866.20.1.36.41.1.3
OSPF routes preference. Specifies the preference with which routes learned by OSPF are imported into the routing tables.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciOspfAsePreference 2.1.866.20.1.36.41.1.4
OSPF ASE preference. Specifies the preference with which routes external to the Autonomous System learned by OSPF are imported into the routing tables.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciOspfVirtualPortsTable 2.1.866.20.1.36.41.10
OSPF Interface Table. The OSPF Interface Table augments the ifTable with OSPF specific information. Each OSPF Interface Entry describes one interface from the viewpoint of OSPF.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciOspfVirtualPortsEntry

fciOspfVirtualPortsEntry 2.1.866.20.1.36.41.10.1
An entry of fciOspfVirtualPortsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciOspfVirtualPortsEntry  

fciOspfVpId 2.1.866.20.1.36.41.10.1.1
OSPF VP id. The VP id identifying this OSPF interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fciOspfVpAdminStatus 2.1.866.20.1.36.41.10.1.2
OSPF VP administrative status. The OSPF interface's administrative status. The value 'on' denotes that neighbor relationships may be formed on the interface, and the interface will be advertised as an internal route to some area. The value 'off' denotes that the interface is external to OSPF. This parameter defaults to the value 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciOspfVpAreaId 2.1.866.20.1.36.41.10.1.3
OSPF VP area id. A 32-bit integer uniquely identifying the area to which the interface connects. This parameter defaults to the value '0.0.0.0' which is used for the OSPF backbone.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciOspfVpMetric 2.1.866.20.1.36.41.10.1.4
OSPF VP metric. The metric of using this type of service on this interface. The default value of the TOS 0 Metric is 10^8 / ifSpeed. The value FFFF is distinguished to mean 'no route via this TOS'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

fciOspfVpType 2.1.866.20.1.36.41.10.1.5
OSPF VP type. The OSPF interface type. By way of a default, this field may be intuited from the corresponding value of ifType. Broadcast LANs, such as Ethernet and IEEE 802.5, take the value 'broadcast', X.25, Frame Relay, and similar technologies take the value 'nbma', and links that are definitively point to point take the value 'pointToPoint'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER broadcast(1), nbma(2), pointToPoint(3)  

fciOspfVpDRPriority 2.1.866.20.1.36.41.10.1.6
OSPF VP DR priority. The priority of this interface. Used in multi-access networks, this field is used in the designated router election algorithm. The value 0 signifies that the router is not eligible to become the designated router on this particular network. In the event of a tie in this value, routers will use their router id as a tie breaker. This parameter defaults to the value '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciOspfVpTransitDelay 2.1.866.20.1.36.41.10.1.7
OSPF VP transit delay. The estimated number of seconds it takes to transmit a link state update packet over this interface. This parameter defaults with the value '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fciOspfVpRetransmitInterval 2.1.866.20.1.36.41.10.1.8
OSPF VP retransmit interval. The number of seconds between link-state advertisement retransmissions, for adjacencies belonging to this interface. This value is also used when retransmitting database description and link-state request packets. This parameter defaults to the value '5'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fciOspfVpHelloInterval 2.1.866.20.1.36.41.10.1.9
OSPF VP hello interval. The length of time, in seconds, between the Hello packets that the router sends on the interface. This value must be the same for all routers attached to a common network.This parameter defaults with the value '10'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciOspfVpRouterDeadInterval 2.1.866.20.1.36.41.10.1.10
OSPF VP router dead interval. The number of seconds that a router's Hello packets have not been seen before it's neighbors declare the router down. This should be some multiple of the Hello interval. This value must be the same for all routers attached to a common network. This parameter defaults with the value '40'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fciOspfVpPollInterval 2.1.866.20.1.36.41.10.1.11
OSPF VP poll interval. The larger time interval, in seconds, between the Hello packets sent to an inactive non-broadcast multi-access neighbor. This parameter defaults with the value '120'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciOspfVpAuthenticationKey 2.1.866.20.1.36.41.10.1.12
OSPF VP authentication key. The Authentication Key. If the Area's Authentication Type is simplePassword, and the key length is shorter than 8 octets, the agent will left adjust and zero fill to 8 octets. When read, ospfIfAuthKey always returns an Octet String of length zero. This parameter defaults with the value '0000000000000000h'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

fciOspfNeighborsTable 2.1.866.20.1.36.41.20
OSPF Neighbors Table. The OSPF Neighbors Table describes all neighbors in the locality of the subject router. Each entry contains the information regarding a single neighbor.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciOspfNeighborsEntry

fciOspfNeighborsEntry 2.1.866.20.1.36.41.20.1
An entry of fciOspfNeighborsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciOspfNeighborsEntry  

fciOspfNeighborIpAddress 2.1.866.20.1.36.41.20.1.1
Neighbor IP address. The IP address of this neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciOspfNeighborStatus 2.1.866.20.1.36.41.20.1.2
Status. The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciOspfNeighborEligibleStatus 2.1.866.20.1.36.41.20.1.3
Neighbor eligible status. This parameter indicates whether the neighbor is eligible for DR election.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciOspfAreasTable 2.1.866.20.1.36.41.30
The OSPF Area Data Structure contains informations regarding the various areas. The interfaces and the virtual links are configured as part of these areas. Area 0.0.0.0, by definition, is the Backbone Area. Each entry describes the configured parameters of one of the router's attached areas.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciOspfAreasEntry

fciOspfAreasEntry 2.1.866.20.1.36.41.30.1
An entry of fciOspfAreasTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciOspfAreasEntry  

fciOspfAreaId 2.1.866.20.1.36.41.30.1.1
Area id. A 32-bit integer uniquely identifying an area. This parameter defaults to the value '0.0.0.0' which is used to identify the OSPF backbone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciOspfAreaStatus 2.1.866.20.1.36.41.30.1.2
Status. The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciOspfAreaAuthType 2.1.866.20.1.36.41.30.1.3
Area authentication type. The authentication type specified for an area. This parameter defaults to the 'none' value and can take the value 'simplePassword' to enable authentication into the area.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), simplePassword(2)  

fciOspfAreaStubStatus 2.1.866.20.1.36.41.30.1.4
Area stub status. This parameter indicates whether the area is a stub area or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciOspfAreaStubMetric 2.1.866.20.1.36.41.30.1.5
Area stub metric. The OSPF metric associated to the stub area.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16777215  

fciOspfAreaRangesTable 2.1.866.20.1.36.41.33
OSPF Address Range Table. The Address Range Table acts as an adjunct to the Area Table ; It describes those Address Range Summaries that are configured to be propagated from an Area to reduce the amount of information about it which is known beyond its borders. A range of IP addresses is specified by an IP address/IP network mask pair. For example, Class B address range of X.X.X.X with a network mask of 255.255.0.0 includes all IP addresses from X.X.0.0 to X.X.255.255.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciOspfAreaRangesEntry

fciOspfAreaRangesEntry 2.1.866.20.1.36.41.33.1
An entry of fciOspfAreaRangesTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciOspfAreaRangesEntry  

fciOspfAreaRangeIpAddress 2.1.866.20.1.36.41.33.1.1
Area range IP address. The IP Address of the Net or Subnet indicated by the range.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciOspfAreaRangeIpMask 2.1.866.20.1.36.41.33.1.2
Area range IP mask. The Subnet Mask that pertains to the Net or Subnet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciOspfAreaRangeStatus 2.1.866.20.1.36.41.33.1.3
Status. The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciOspfAreaRangeAreaId 2.1.866.20.1.36.41.33.1.4
Area range area id. The Area the Address Range is to be found within.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fciOspfAreaRangeRestrict 2.1.866.20.1.36.41.33.1.5
Restriction. The value 'off' indicates that intra-area LSAs that fall within the specified range are not advertised into other areas as inter-area routes. Instead, the specified range are advertised as summary network LSAs. The value 'on' specifies that the summary network LSAs are not advertised.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciOspfVirtualLinksTable 2.1.866.20.1.36.41.36
OSPF Virtual Link Table. The Virtual Link Table describes the virtual links that the OSPF Process is configured to carry on.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciOspfVirtualLinksEntry

fciOspfVirtualLinksEntry 2.1.866.20.1.36.41.36.1
An entry of fciOspfVirtualLinksTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciOspfVirtualLinksEntry  

fciOspfVlNeighborId 2.1.866.20.1.36.41.36.1.1
VL neighbor id. The Router ID of the Virtual Neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciOspfVlTransitAreaId 2.1.866.20.1.36.41.36.1.2
VL transit area id. The Transit Area that the Virtual Link traverses. By definition, this is not 0.0.0.0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciOspfVlStatus 2.1.866.20.1.36.41.36.1.3
Status. The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciOspfVlDRPriority 2.1.866.20.1.36.41.36.1.4
VL DR priority. The priority of this virtual link. Used in multi-access networks, this field is used in the designated router election algorithm. The value 0 signifies that the router is not eligible to become the designated router on this particular network. In the event of a tie in this value, routers will use their router id as a tie breaker. This parameter defaults to the value '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciOspfVlTransitDelay 2.1.866.20.1.36.41.36.1.5
VL transit delay. The estimated number of seconds it takes to transmit a link-state update packet over this interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fciOspfVlRetransmitInterval 2.1.866.20.1.36.41.36.1.6
VL retransmit interval. The number of seconds between link-state advertisement retransmissions, for adjacencies belonging to this interface. This value is also used when retransmitting database description and link-state request packets. This value should be well over the expected round-trip.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fciOspfVlHelloInterval 2.1.866.20.1.36.41.36.1.7
VL hello interval. The length of time, in seconds, between the Hello packets that the router sends on the interface. This value must be the same for the virtual neighbor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fciOspfVlRouterDeadInterval 2.1.866.20.1.36.41.36.1.8
VL router dead interval. The number of seconds that a router's Hello packets have not been seen before it's neighbors declare the router down. This should be some multiple of the Hello interval. This value must be the same for the virtual neighbor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fciOspfVlAuthenticationKey 2.1.866.20.1.36.41.36.1.9
VL authentication key. If Authentication Type is simplePassword, the device will left adjust and zero fill to 8 octets. When read, ospfVifAuthKey always returns a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

fciOspfExportingGroup 2.1.866.20.1.36.41.40
OBJECT IDENTIFIER    

fciOspfAseExportInterval 2.1.866.20.1.36.41.40.1
ASE flow packets interval. Together with fciOspfAseExportLimit, controls the rate at which Autonomous System External (ASE) routes are imported. The rate is defined as the ratio of fciOspfAseExportLimit and fciOspfAseExportInterval, in number of routes per second. By default, ASE routes are imported at the rate of 100 ASEs per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fciOspfAseExportLimit 2.1.866.20.1.36.41.40.2
ASE flow packets limit. Together with fciOspfAseExportInterval, controls the rate at which Autonomous System External (ASE) routes are imported. The rate is defined as the ratio of fciOspfAseExportLimit and fciOspfAseExportInterval, in number of routes per second. By default, ASE routes are imported at the rate of 100 ASEs per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fciOspfAseExportStaticsStatus 2.1.866.20.1.36.41.40.3
Statics ASE export status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciOspfAseExportStaticsMetric 2.1.866.20.1.36.41.40.4
Statics ASE export metric. The default metric (or cost) used by OSPF when propagating (exporting) routes learned via other protocols.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16777215  

fciOspfAseExportStaticsTag 2.1.866.20.1.36.41.40.5
Statics ASE export tag. The OSPF tag to be placed on all routes exported by OSPF. Specifies one way of generating OSPF tags.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483648  

fciOspfAseExportStaticsType 2.1.866.20.1.36.41.40.6
Statics ASE export type The OSPF external routes type used to export static routes. The value '1' indicates that the metric of the static routes exported are directly comparable with OSPF metric. The value '2' indicates the contrary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2  

fciOspfAseExportRipStatus 2.1.866.20.1.36.41.40.7
RIP ASE export status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciOspfAseExportRipMetric 2.1.866.20.1.36.41.40.8
RIP ASE export metric. The default metric (or cost) used by OSPF when propagating (exporting) routes learned via other protocols.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16777215  

fciOspfAseExportRipTag 2.1.866.20.1.36.41.40.9
RIP ASE export tag. The OSPF tag to be placed on all routes exported by OSPF. Specifies one way of generating OSPF tags.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483648  

fciOspfAseExportRipType 2.1.866.20.1.36.41.40.10
RIP ASE export type The OSPF external routes type used to export RIP routes. The value '1' indicates that the metric of the static routes exported are directly comparable with OSPF metric. The value '2' indicates the contrary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2  

fciEgp 2.1.866.20.1.36.45
OBJECT IDENTIFIER    

fciEgpAdminStatus 2.1.866.20.1.36.45.1
The value of this object indicates whether EGP (Exterior Gateway Protocol) is enabled or not. fciEgpNeighborTable must contain at least one entry. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciEgpAutonomousSystemNumber 2.1.866.20.1.36.45.2
The value of this object defines the autonomous system to which belongs this IP router. The authorized values are '1..65534'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

fciEgpStaticRoutesDistribution 2.1.866.20.1.36.45.3
The value of this object indicates whether EGP distributes static entries of the routing table (i.e., those defined in fciIpRouteTable) or not.. The autonomous systems to which these routing informations are distributed are defined in fciEgpTargetAsDistributionTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciEgpRipRoutesDistribution 2.1.866.20.1.36.45.4
The value of this object indicates whether EGP distributes entries of the routing table learnt by RIP (Routing Information Protocol) or not. The autonomous systems to which these routing informations are distributed are defined in fciEgpTargetAsDistributionTable. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciEgpMetricDistribution 2.1.866.20.1.36.45.5
The value of this object is the value indicated in the transmitted EGP datagrams concerning routing information learnt by RIP. The authorized values are '1..255'. The default value is '128'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fciEgpNeighborTable 2.1.866.20.1.36.45.10
This table defines the EGP neighbors with witch EGP exchanges routing informations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciEgpNeighborEntry

fciEgpNeighborEntry 2.1.866.20.1.36.45.10.1
An entry of fciEgpNeighborTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciEgpNeighborEntry  

fciEgpNeighborIpAddress 2.1.866.20.1.36.45.10.1.1
The value of this object is the IP address of an EGP neighbor. This IP address must be a valid host address. The default value is '0.0.0.0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciEgpNeighborStatus 2.1.866.20.1.36.45.10.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciEgpNeighborAsNumber 2.1.866.20.1.36.45.10.1.3
The value of this object defines the autonomous system to which belongs this EGP neighbor. The authorized values are '1..65534'. The default value is '1'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

fciEgpTargetAsDistributionTable 2.1.866.20.1.36.45.15
As defined by fciEgpStaticRoutesDistribution and fciEgpRipRoutesDistribution, when EGP distributes static entries or entries of the routing table learnt by RIP (Routing Information Protocol), this table defines to which autonomous systems these entries are to be distributed. Only neighbors of an automous system specified in this table will receive these routing informations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciEgpTargetAsDistributionEntry

fciEgpTargetAsDistributionEntry 2.1.866.20.1.36.45.15.1
An entry of fciEgpTargetAsDistributionTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciEgpTargetAsDistributionEntry  

fciEgpTargetAsNumber 2.1.866.20.1.36.45.15.1.1
The value of this object identifies an autonomous system containing routers to which EGP distributes the routing informations. This AS must exist in fciEgpNeighborTable. The authorized values are '1..65534'. The default value is '0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65534  

fciEgpTargetAsStatus 2.1.866.20.1.36.45.15.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciSnmp 2.1.866.20.1.36.50
OBJECT IDENTIFIER    

fciSnmpCommunityStringReadOnly 2.1.866.20.1.36.50.1
The value of this object is the string which identifies the 'public' community. The managers of this community have only 'read-only' access rights even on the objects with read-write access. The SNMP agent of this equipment compares the community string of a received GetRequest or GetNextRequest to this value to know whether it makes a GetResponse or not. This value may contain up to 14 printable characters. The default value is 'public'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..14)  

fciSnmpCommunityStringReadWrite 2.1.866.20.1.36.50.2
The value of this object is the string which identifies the 'administrator' community. The managers of this community have complete access rights (i.e. they have the rights which are defined in the MIB). The SNMP agent of this equipment compares the community string of a received GetRequest, GetNextRequest or SetRequest to this value to know whether it makes a GetResponse or not. This value may contain up to 14 printable characters. The default value is 'private'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..14)  

fciSnmpCommunityStringTrap 2.1.866.20.1.36.50.3
The value of this object is the string which identifies the 'alarm' community. The managers of this community may filter the received Traps according of this community string. The SNMP agent of this equipment sets the community string of all the sent Trap to this value. It sends traps to the managers defined in fciSnmpManagerTable. This value may contain up to 14 printable characters. The default value is 'private'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..14)  

fciSnmpAuthenticationFailureTrap 2.1.866.20.1.36.50.5
The value of this object specifies whether the SNMP agent sends the authenticationFailure trap or not. When enabled, this trap is sent with each reception of an unauthorized SNMP request (erroneous community string or manager not authorized). It can be useful to disable this sending when unauthorized SNMP managers polls very often the SNMP agent because the quantity of authenticationFailure trap is then very important and prevents the 'good' manager to show correctly the significant traps. The default value is 'off'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciSnmpModule0TrapSourceAddrVpId 2.1.866.20.1.36.50.10
The SNMP agent of module 0 indicates, as the source address of each TRAP, the IP address associated with the virtual port identified by this value. This virtual port must exist in fciVirtualPortTable. The authorized values are '0..199'. The default value is '0'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..11  

fciSnmpModule1TrapSourceAddrVpId 2.1.866.20.1.36.50.11
The SNMP agent of module 1 indicates, as the source address of each TRAP, the IP address associated with the virtual port identified by this value. This virtual port must exist in fciVirtualPortTable. The authorized values are '0..199'. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..11  

fciSnmpModule2TrapSourceAddrVpId 2.1.866.20.1.36.50.12
The SNMP agent of module 1 indicates, as the source address of each TRAP, the IP address associated with the virtual port identified by this value. This virtual port must exist in fciVirtualPortTable. The authorized values are '0..199'. The default value is '255' meaning 'empty value' (blank value on the equipment configurator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..11  

fciSnmpManagerFiltering 2.1.866.20.1.36.50.15
The value of this object specifies whether the SNMP agent answers to all the SNMP managers or only to those defined in fciSnmpManagerTable. When set to 'on' the SNMP agent sends an authenticationFailure trap (if enabled) each time it receives a request from a manager not in the table. The default value is 'off' (i.e., no filtering : access for all managers)..
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciSnmpManagerTable 2.1.866.20.1.36.50.20
This table contains the SNMP managers to which SNMP traps may be sent. This table is also used to define the authorized managers when fciSnmpManagerFiltering is set to 'on'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciSnmpManagerEntry

fciSnmpManagerEntry 2.1.866.20.1.36.50.20.1
An entry of fciSnmpManagerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciSnmpManagerEntry  

fciSnmpManagerIpAddress 2.1.866.20.1.36.50.20.1.1
The value of this object is the IP address of an SNMP manager. This IP address must be a valid host address. The default value is '0.0.0.0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciSnmpManagerStatus 2.1.866.20.1.36.50.20.1.2
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciSnmpManagerSendTraps 2.1.866.20.1.36.50.20.1.3
The value of this object specifies whether the SNMP agent sends the traps to this SNMP manager or not. The default value is 'on'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fciSnmpManagerTrapsUdpPort 2.1.866.20.1.36.50.20.1.4
The value of this object indicates the UDP port to which are sent the SNMP traps. This value must be the value used by this SNMP manager when it listens for SNMP traps. The authorized values are '0..65535'. The default value is '162'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fciBootP 2.1.866.20.1.36.60
OBJECT IDENTIFIER    

fciBootPClient 2.1.866.20.1.36.60.1
OBJECT IDENTIFIER    

fciBootPClientStart 2.1.866.20.1.36.60.1.1
The value of this object identifies start mode of equipement. The default value is 'no'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fciBootPClientServer 2.1.866.20.1.36.60.1.2
The value of this object identifies server name. This value may contain up to 64 printable characters. The default value is an empty string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..64)  

fciBootPClientBootFile 2.1.866.20.1.36.60.1.3
The value of this object identifies generic name of bootfile. This value may contain up to 64 printable characters. The default value is an empty string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..64)  

fciBootPClientBootTime 2.1.866.20.1.36.60.1.4
The value of this object identifies time to wait before bootp launching. Time is specified in seconds. The authorized values are '15..900'. The default value is '180'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 15..900  

fciBootPClientRetransNb 2.1.866.20.1.36.60.1.5
The value of this object identifies numbers of retransmissions of bootrequest packet. The authorized values are '0..10'. The default value is '5'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..10  

fciBootPInterfaceTable 2.1.866.20.1.36.60.1.20
This table describes the parameters of BootP Virtual Ports. It offers a solution to link many servers on the bootp client or relay.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciBootPInterfaceEntry

fciBootPInterfaceEntry 2.1.866.20.1.36.60.1.20.1
An entry of fciBootPInterfaceTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciBootPInterfaceEntry  

fciBootPInterfaceVpId 2.1.866.20.1.36.60.1.20.1.1
The value of this object identifies one virtual port. The default value is '255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fciBootPInterfaceIpAddress 2.1.866.20.1.36.60.1.20.1.2
The value of this object is the IP address associated to one bootp interface. The default value is '255.255.255.255'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fciBootPInterfaceStatus 2.1.866.20.1.36.60.1.20.1.3
The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid' to delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciBootPInterfaceType 2.1.866.20.1.36.60.1.20.1.4
The value of this object indicates the fonctionnality of the equipement. The authorized values are 'client' or 'relay'. The default value is 'client'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER client(1), relay(2)  

fciTelnet 2.1.866.20.1.36.70
OBJECT IDENTIFIER    

fciTelnetConfiguration 2.1.866.20.1.36.70.1
OBJECT IDENTIFIER    

fciTelnetMaxSession 2.1.866.20.1.36.70.1.1
Maximum number of telnet session that the equipment would accept. This number include the telnet session issuing from the equipment. The modification of this parameter need a reboot of the equipment. The default value is 6.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..50  

fciTelnetTimer 2.1.866.20.1.36.70.1.2
This parameter is global to all connection and set the timer that make a session to be disconnected if no traffic is send or receive in the telnet session. The modification of the parameter takes effect after a hot reset and is used for new connections
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

fciTelnetPwd 2.1.866.20.1.36.70.10
OBJECT IDENTIFIER    

fciTelnetPwdP0 2.1.866.20.1.36.70.10.1
This parameter set the password to access to a priority 0 level. All the user set to a priority 0 level have to uses this password. The modification of the parameter takes effect after a hot reset and is used for new connections The default value is 'root'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetPwdP1 2.1.866.20.1.36.70.10.2
This parameter set the password to access to a priority 1 level. All the user set to a priority 1 level have to uses this password. The modification of the parameter takes effect after a hot reset and is used for new connections The default value is 'user'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetPwdP2 2.1.866.20.1.36.70.10.3
This parameter set the password to access to a priority 2 level. All the user set to a priority 2 level have to uses this password. The modification of the parameter takes effect after a hot reset and is used for new connections The default value is 'user'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetPwdP3 2.1.866.20.1.36.70.10.4
This parameter set the password to access to a priority 3 level. All the user set to a priority 3 level have to uses this password. The modification of the parameter takes effect after a hot reset and is used for new connections The default value is 'user'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetPwdP4 2.1.866.20.1.36.70.10.5
This parameter set the password to access to a priority 4 level. All the user set to a priority 4 level have to uses this password. The modification of the parameter takes effect after a hot reset and is used for new connections The default value is 'user'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetPwdP5 2.1.866.20.1.36.70.10.6
This parameter set the password to access to a priority 5 level. All the user set to a priority 5 level have to uses this password. The modification of the parameter takes effect after a hot reset and is used for new connections The default value is 'user'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetPwdP6 2.1.866.20.1.36.70.10.7
This parameter set the password to access to a priority 6 level. All the user set to a priority 6 level have to uses this password. The modification of the parameter takes effect after a hot reset and is used for new connections The default value is 'user'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetPwdP7 2.1.866.20.1.36.70.10.8
This parameter set the password to access to a priority 7 level. All the user set to a priority 7 level have to uses this password. The modification of the parameter takes effect after a hot reset and is used for new connections The default value is 'user'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetPwdP8 2.1.866.20.1.36.70.10.9
This parameter set the password to access to a priority 8 level. All the user set to a priority 8 level have to uses this password. The modification of the parameter takes effect after a hot reset and is used for new connections The default value is 'user'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetPwdP9 2.1.866.20.1.36.70.10.10
This parameter set the password to access to a priority 9 level. All the user set to a priority 9 level have to uses this password. The modification of the parameter takes effect after a hot reset and is used for new connections The default value is 'user'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetUserTable 2.1.866.20.1.36.70.30
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FciTelnetUserEntry

fciTelnetUserEntry 2.1.866.20.1.36.70.30.1
An entry of fciTelnetUserTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FciTelnetUserEntry  

fciTelnetUserId 2.1.866.20.1.36.70.30.1.1
This parameter identify the user.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..49  

fciTelnetUserStatus 2.1.866.20.1.36.70.30.1.2
This parameter set the status of the raw
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fciTelnetUserLogin 2.1.866.20.1.36.70.30.1.3
This parameter set the login identification of the user. The password ask to the user would the associated priority password. The modification of the parameter takes effect after a hot reset and is used for new connections.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

fciTelnetUserPriority 2.1.866.20.1.36.70.30.1.4
This parameter associate a priority level to a user. The priority level give access right to different service. The default value is set to the lower priority level. The modification of the parameter takes effect after a hot reset and is used for new connections.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9  

fcIpx 2.1.866.20.1.37
OBJECT IDENTIFIER    

fcxInstance 2.1.866.20.1.37.1
OBJECT IDENTIFIER    

fcxIpxRouting 2.1.866.20.1.37.1.1
Activation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxBasicSysName 2.1.866.20.1.37.1.12
ipxBasicSysName
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..47)  

fcxAdvSysMaxPathSplits 2.1.866.20.1.37.1.15
ipxAdvSysMaxPathSplits
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..32  

fcxAdvSysMaxHops 2.1.866.20.1.37.1.16
ipxAdvSysMaxHops
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..255  

fcxCircuits 2.1.866.20.1.37.10
OBJECT IDENTIFIER    

fcxCircuitTable 2.1.866.20.1.37.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxCircuitEntry

fcxCircuitEntry 2.1.866.20.1.37.10.1.1
An entry of fcxCircuitTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxCircuitEntry  

fcxCircCircuitId 2.1.866.20.1.37.10.1.1.1
Circuit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..199  

fcxCircStatus 2.1.866.20.1.37.10.1.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcxCircVirtualPortId 2.1.866.20.1.37.10.1.1.3
VP id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..11  

fcxCircOperState 2.1.866.20.1.37.10.1.1.10
ipxCircOperState
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER down(1), up(2)  

fcxCircName 2.1.866.20.1.37.10.1.1.11
ipxCircName
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..24)  

fcxCircType 2.1.866.20.1.37.10.1.1.12
ipxCircType
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER broadcast(2), ptToPt(3), dynamic(6)  

fcxCircLocalMaxPacketSize 2.1.866.20.1.37.10.1.1.13
ipxCircLocalMaxPacketSize
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 512..65535  

fcxCircNetNumber 2.1.866.20.1.37.10.1.1.14
ipxCircNetNumber
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcxCircChecksumEnabling 2.1.866.20.1.37.10.1.1.20
Calcul du checksum
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxCircuitLocalVpTable 2.1.866.20.1.37.10.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxCircuitLocalVpEntry

fcxCircuitLocalVpEntry 2.1.866.20.1.37.10.2.1
An entry of fcxCircuitLocalVpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxCircuitLocalVpEntry  

fcxCircLvpCircuitId 2.1.866.20.1.37.10.2.1.1
Circuit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..199  

fcxCircLvpStatus 2.1.866.20.1.37.10.2.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcxCircLvpEncapsulation 2.1.866.20.1.37.10.2.1.3
Encapsulation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ethernet(1), ether802-3(2), ether802-2(3), etherSnap(4)  

fcxCircuitRemoteVpTable 2.1.866.20.1.37.10.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxCircuitRemoteVpEntry

fcxCircuitRemoteVpEntry 2.1.866.20.1.37.10.3.1
An entry of fcxCircuitRemoteVpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxCircuitRemoteVpEntry  

fcxCircRvpCircuitId 2.1.866.20.1.37.10.3.1.1
Circuit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..199  

fcxCircRvpStatus 2.1.866.20.1.37.10.3.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcxCircRvpRemoteAddress 2.1.866.20.1.37.10.3.1.3
Adresse WAN
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fcxCircRvpLocalNode 2.1.866.20.1.37.10.3.1.4
Adresse locale
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

fcxRouting 2.1.866.20.1.37.20
OBJECT IDENTIFIER    

fcxRoutInstance 2.1.866.20.1.37.20.1
OBJECT IDENTIFIER    

fcxRoutType20PacketBroadcasting 2.1.866.20.1.37.20.1.10
Diffusion des paquets IPX de type 20
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), onLanOnly(2), on(3)  

fcxRoutCircuitTable 2.1.866.20.1.37.20.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxRoutCircuitEntry

fcxRoutCircuitEntry 2.1.866.20.1.37.20.10.1
An entry of fcxRoutCircuitTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxRoutCircuitEntry  

fcxRoutCircCircuitId 2.1.866.20.1.37.20.10.1.1
Circuit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..199  

fcxRoutCircNcpSpoofing 2.1.866.20.1.37.20.10.1.2
Netware Core Protocol Spoofing
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxRoutCircType20PacketBroadcasting 2.1.866.20.1.37.20.10.1.3
Diffusion des paquets IPX de type 20
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxRoutCircAddressFiltering 2.1.866.20.1.37.20.10.1.4
Filtrage sur adresse IPX
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), permitted(2), denied(3)  

fcxRoutIpxStaticRouteTable 2.1.866.20.1.37.20.20
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxRoutIpxStaticRouteEntry

fcxRoutIpxStaticRouteEntry 2.1.866.20.1.37.20.20.1
An entry of fcxRoutIpxStaticRouteTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxRoutIpxStaticRouteEntry  

fcxRoutStaticRouteCircuitId 2.1.866.20.1.37.20.20.1.1
ipxStaticRouteCircIndex
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..199  

fcxRoutStaticRouteNetNum 2.1.866.20.1.37.20.20.1.2
ipxStaticRouteNetNum
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcxRoutStaticRouteStatus 2.1.866.20.1.37.20.20.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcxRoutStaticRouteTicks 2.1.866.20.1.37.20.20.1.4
ipxStaticRouteTicks en 1/60eme de seconde
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

fcxRoutStaticRouteHopCount 2.1.866.20.1.37.20.20.1.5
ipxStaticRouteHopCount
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fcxRoutAddressFilteringTable 2.1.866.20.1.37.20.30
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxRoutAddressFilteringEntry

fcxRoutAddressFilteringEntry 2.1.866.20.1.37.20.30.1
An entry of fcxRoutAddressFilteringTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxRoutAddressFilteringEntry  

fcxRoutAddrFltCircuitId 2.1.866.20.1.37.20.30.1.1
Circuit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..199  

fcxRoutAddrFltFilterId 2.1.866.20.1.37.20.30.1.2
Filtre id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcxRoutAddrFltStatus 2.1.866.20.1.37.20.30.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcxRoutAddrFltFiltering 2.1.866.20.1.37.20.30.1.4
Activation du filtre
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxRoutAddrFltField 2.1.866.20.1.37.20.30.1.5
Champ
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sourceNetAddress(1), destNetAddress(2), sourceSocket(3), destSocket(4)  

fcxRoutAddrFltMask 2.1.866.20.1.37.20.30.1.6
Masque
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcxRoutAddrFltValue 2.1.866.20.1.37.20.30.1.7
Valeur
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcxRoutingInformationProtocol 2.1.866.20.1.37.25
OBJECT IDENTIFIER    

fcxRipInstance 2.1.866.20.1.37.25.1
OBJECT IDENTIFIER    

fcxRipSysState 2.1.866.20.1.37.25.1.1
ripSysState
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxRipInputFiltering 2.1.866.20.1.37.25.1.2
Filtrage RIP en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), permitted(2), denied(3)  

fcxRipCircuitTable 2.1.866.20.1.37.25.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxRipCircuitEntry

fcxRipCircuitEntry 2.1.866.20.1.37.25.10.1
An entry of fcxRipCircuitTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxRipCircuitEntry  

fcxRipCircCircuitId 2.1.866.20.1.37.25.10.1.1
Circuit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..199  

fcxRipCircState 2.1.866.20.1.37.25.10.1.10
ripCircState
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxRipCircPace 2.1.866.20.1.37.25.10.1.11
ripCircPace
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

fcxRipCircUpdate 2.1.866.20.1.37.25.10.1.12
ripCircUpdate
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fcxRipCircAgeMultiplier 2.1.866.20.1.37.25.10.1.13
ripCircAgeMultiplier
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..255  

fcxRipCircPacketSize 2.1.866.20.1.37.25.10.1.14
ripCircPacketSize
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 512..65535  

fcxRipCircOutputFiltering 2.1.866.20.1.37.25.10.1.20
Filtrage RIP en sortie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), permitted(2), denied(3)  

fcxRipInputFilteringTable 2.1.866.20.1.37.25.11
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxRipInputFilteringEntry

fcxRipInputFilteringEntry 2.1.866.20.1.37.25.11.1
An entry of fcxRipInputFilteringTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxRipInputFilteringEntry  

fcxRipInFltFilterId 2.1.866.20.1.37.25.11.1.1
Filtre id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcxRipInFltStatus 2.1.866.20.1.37.25.11.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcxRipInFltFiltering 2.1.866.20.1.37.25.11.1.3
Activation du filtre
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxRipInFltNetAddress 2.1.866.20.1.37.25.11.1.4
Adresse reseau
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcxRipInFltMask 2.1.866.20.1.37.25.11.1.5
Masque adresse
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcxRipOutputFilteringTable 2.1.866.20.1.37.25.12
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxRipOutputFilteringEntry

fcxRipOutputFilteringEntry 2.1.866.20.1.37.25.12.1
An entry of fcxRipOutputFilteringTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxRipOutputFilteringEntry  

fcxRipOutFltCircuitId 2.1.866.20.1.37.25.12.1.1
Circuit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..199  

fcxRipOutFltFilterId 2.1.866.20.1.37.25.12.1.2
Filtre id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcxRipOutFltStatus 2.1.866.20.1.37.25.12.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcxRipOutFltFiltering 2.1.866.20.1.37.25.12.1.4
Activation du filtre
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxRipOutFltNetAddress 2.1.866.20.1.37.25.12.1.5
Adresse reseau
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcxRipOutFltMask 2.1.866.20.1.37.25.12.1.6
Masque adresse
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcxServices 2.1.866.20.1.37.30
OBJECT IDENTIFIER    

fcxServInstance 2.1.866.20.1.37.30.1
OBJECT IDENTIFIER    

fcxServSapSysState 2.1.866.20.1.37.30.1.1
sapSysState
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxServSapInputFiltering 2.1.866.20.1.37.30.1.12
Filtrage SAP en entree
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), permitted(2), denied(3)  

fcxServCircuitTable 2.1.866.20.1.37.30.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxServCircuitEntry

fcxServCircuitEntry 2.1.866.20.1.37.30.10.1
An entry of fcxServCircuitTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxServCircuitEntry  

fcxServCircSapCircuitId 2.1.866.20.1.37.30.10.1.1
sapCircIndex
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..199  

fcxServCircSapState 2.1.866.20.1.37.30.10.1.2
sapCircState
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxServCircSapPace 2.1.866.20.1.37.30.10.1.3
sapCircPace
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

fcxServCircSapUpdate 2.1.866.20.1.37.30.10.1.4
sapCircUpdate
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fcxServCircSapAgeMultiplier 2.1.866.20.1.37.30.10.1.5
sapCircAgeMultiplier
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..255  

fcxServCircSapPacketSize 2.1.866.20.1.37.30.10.1.6
sapCircPacketSize
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 512..65535  

fcxServCircSapGetNearestServerReply 2.1.866.20.1.37.30.10.1.7
sapCircGetNearestServerReply
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fcxServCircSapOutputFiltering 2.1.866.20.1.37.30.10.1.10
Filtrage SAP en sortie
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), permitted(2), denied(3)  

fcxServStaticServiceTable 2.1.866.20.1.37.30.20
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxServStaticServiceEntry

fcxServStaticServiceEntry 2.1.866.20.1.37.30.20.1
An entry of fcxServStaticServiceTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxServStaticServiceEntry  

fcxServStaticServiceId 2.1.866.20.1.37.30.20.1.1
Service Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcxServStaticStatus 2.1.866.20.1.37.30.20.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcxServStaticCircuitId 2.1.866.20.1.37.30.20.1.3
ipxStaticServCircIndex
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..199  

fcxServStaticName 2.1.866.20.1.37.30.20.1.4
ipxStaticServName
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..47)  

fcxServStaticType 2.1.866.20.1.37.30.20.1.5
ipxStaticServType
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

fcxServStaticNetNum 2.1.866.20.1.37.30.20.1.6
ipxStaticServNetNum
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

fcxServStaticNode 2.1.866.20.1.37.30.20.1.7
ipxStaticServNode
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

fcxServStaticSocket 2.1.866.20.1.37.30.20.1.8
ipxStaticServSocket
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

fcxServStaticHopCount 2.1.866.20.1.37.30.20.1.9
ipxStaticServHopCount
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fcxServSapInputFilteringTable 2.1.866.20.1.37.30.30
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxServSapInputFilteringEntry

fcxServSapInputFilteringEntry 2.1.866.20.1.37.30.30.1
An entry of fcxServSapInputFilteringTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxServSapInputFilteringEntry  

fcxServSapInFltFilterId 2.1.866.20.1.37.30.30.1.1
Filtre id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcxServSapInFltStatus 2.1.866.20.1.37.30.30.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcxServSapInFltFiltering 2.1.866.20.1.37.30.30.1.3
Activation du filtre
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxServSapInFltCheckedField 2.1.866.20.1.37.30.30.1.4
Champ evalue
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER name(1), type(2), nameAndType(3)  

fcxServSapInFltServiceNameType 2.1.866.20.1.37.30.30.1.5
Type de nom de service
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fullName(1), beginningPattern(2)  

fcxServSapInFltServiceName 2.1.866.20.1.37.30.30.1.6
Nom de service
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..47)  

fcxServSapInFltServiceType 2.1.866.20.1.37.30.30.1.7
Type de service
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

fcxServSapOutputFilteringTable 2.1.866.20.1.37.30.31
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FcxServSapOutputFilteringEntry

fcxServSapOutputFilteringEntry 2.1.866.20.1.37.30.31.1
An entry of fcxServSapOutputFilteringTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FcxServSapOutputFilteringEntry  

fcxServSapOutFltCircuitId 2.1.866.20.1.37.30.31.1.1
Circuit id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..199  

fcxServSapOutFltFilterId 2.1.866.20.1.37.30.31.1.2
Filtre id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fcxServSapOutFltStatus 2.1.866.20.1.37.30.31.1.3
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fcxServSapOutFltFiltering 2.1.866.20.1.37.30.31.1.4
Activation du filtre
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fcxServSapOutFltCheckedField 2.1.866.20.1.37.30.31.1.5
Champ evalue
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER name(1), type(2), nameAndType(3)  

fcxServSapOutFltServiceNameType 2.1.866.20.1.37.30.31.1.6
Type de nom de service
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fullName(1), beginningPattern(2)  

fcxServSapOutFltServiceName 2.1.866.20.1.37.30.31.1.7
Nom de service
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..47)  

fcxServSapOutFltServiceType 2.1.866.20.1.37.30.31.1.8
Type de service
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

fcClnp 2.1.866.20.1.38
OBJECT IDENTIFIER    

fccClnpRouting 2.1.866.20.1.38.1
AdminStatus
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fccLocalNetworkEntityTitle 2.1.866.20.1.38.2
LocalNet
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(22)  

fccErrorFramesSending 2.1.866.20.1.38.4
ErrorFrames
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fccVirtualPortTable 2.1.866.20.1.38.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FccVirtualPortEntry

fccVirtualPortEntry 2.1.866.20.1.38.10.1
An entry of fccVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FccVirtualPortEntry  

fccVpVirtualPortId 2.1.866.20.1.38.10.1.1
VP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fccVpStatus 2.1.866.20.1.38.10.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fccVpMtu 2.1.866.20.1.38.10.1.4
MTU
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 512..1600  

fccLocalVirtualPortTable 2.1.866.20.1.38.11
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FccLocalVirtualPortEntry

fccLocalVirtualPortEntry 2.1.866.20.1.38.11.1
An entry of fccLocalVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FccLocalVirtualPortEntry  

fccLvpVirtualPortId 2.1.866.20.1.38.11.1.1
VP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fccLvpStatus 2.1.866.20.1.38.11.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fccLvpEsIsRedirection 2.1.866.20.1.38.11.1.3
EsIsRedirects
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fccLvpEsIsConfigTimer 2.1.866.20.1.38.11.1.4
EsIsConfigTimer
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

fccLvpEsIsHoldingTimer 2.1.866.20.1.38.11.1.5
EsIsHoldingTimer
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

fccNeighborTable 2.1.866.20.1.38.20
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FccNeighborEntry

fccNeighborEntry 2.1.866.20.1.38.20.1
An entry of fccNeighborTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FccNeighborEntry  

fccNeighNeighborId 2.1.866.20.1.38.20.1.1
Neighbor id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fccNeighStatus 2.1.866.20.1.38.20.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fccNeighType 2.1.866.20.1.38.20.1.3
Type
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER es(1), is(2)  

fccNeighVirtualPortId 2.1.866.20.1.38.20.1.4
VP id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..11  

fccNeighClnpAddress 2.1.866.20.1.38.20.1.5
Adresse IP-ISO
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(22)  

fccLocalNeighborTable 2.1.866.20.1.38.21
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FccLocalNeighborEntry

fccLocalNeighborEntry 2.1.866.20.1.38.21.1
An entry of fccLocalNeighborTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FccLocalNeighborEntry  

fccLneighNeighborId 2.1.866.20.1.38.21.1.1
Neighbor id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fccLneighStatus 2.1.866.20.1.38.21.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fccLneighMacAddress 2.1.866.20.1.38.21.1.3
Adresse MAC
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

fccRemoteNeighborTable 2.1.866.20.1.38.22
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FccRemoteNeighborEntry

fccRemoteNeighborEntry 2.1.866.20.1.38.22.1
An entry of fccRemoteNeighborTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FccRemoteNeighborEntry  

fccRneighNeighborId 2.1.866.20.1.38.22.1.1
Neighbor id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fccRneighStatus 2.1.866.20.1.38.22.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fccRneighRemoteAddress 2.1.866.20.1.38.22.1.3
Adresse WAN
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

fccClnpRouteTable 2.1.866.20.1.38.30
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FccClnpRouteEntry

fccClnpRouteEntry 2.1.866.20.1.38.30.1
An entry of fccClnpRouteTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FccClnpRouteEntry  

fccRoutRouteId 2.1.866.20.1.38.30.1.1
Route id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..199  

fccRoutStatus 2.1.866.20.1.38.30.1.2
Status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fccRoutDestClnpAddress 2.1.866.20.1.38.30.1.3
Adresse IP-ISO destination
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(22)  

fccRoutNextHopNeighborId 2.1.866.20.1.38.30.1.5
Next Hop neighbor id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

fmEvents 2.1.866.20.10.5
OBJECT IDENTIFIER    

fmeTroubleReport 2.1.866.20.10.5.1
OBJECT IDENTIFIER    

fmeTrblEventType 2.1.866.20.10.5.1.1
The value of this object is the cause of the system starting.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER startAfterUnintentionalCrash(1), startAfterDeliberateCrash(2), startAfterHardwareResetOrStartUp(3)  

fmeTroubleReportInfoTable 2.1.866.20.10.5.1.2
This table contains the additional information about the trouble report. It's the fatal error zone : the snapshot of the memory and registers when there is a trouble. It contains the registers state, the system stack ...
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmeTroubleReportInfoEntry

fmeTroubleReportInfoEntry 2.1.866.20.10.5.1.2.1
An entry of fmeTroubleReportInfoTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmeTroubleReportInfoEntry  

fmeTrblInfoIndex 2.1.866.20.10.5.1.2.1.1
The value of this object identifies one and only one element of the trouble report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..194  

fmeTrblInfoData 2.1.866.20.10.5.1.2.1.2
The value of this object is the data of this element of the trouble report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

fmeFamilyTable 2.1.866.20.10.5.2
This table contains general information about the families of the outstanding events. For one family, the maximum number of stored events is 6, but all the families can store simultaneously at most 3 events. So, the maximum number can fluctuate following the busy memory. When one event is added to the list of one family, the oldest event is kept in memory, and the event is added at the end of the list, with the possibility of a rotation of the stored events if there is no free memory.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmeFamilyEntry

fmeFamilyEntry 2.1.866.20.10.5.2.1
An entry of fmeFamilyTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmeFamilyEntry  

fmeFamFamilyId 2.1.866.20.10.5.2.1.1
The value of this object identifies one and only one family.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER troubleReport-00(1), management-01(2), synchronousSignalling-02(3), x25SynchronousProcedure-03(4), synchronousLink-04(5), linePhysicalLevel-05(6), asynchronousProtocolLevel-06(7), asynchronousCommandSyntax-07(8), asynchronousSemanticLevel-08(9), sdlcProcedure-09(10), vipProcedure-0A(11), tvipFradBscProcedure-0B(12), dlcBscProcedure-0C(13), mlp-0D(14), pstnProcedure-0E(15), securizedVcEsv-0F(16), securizedVcN4-10(17), securizedVcIr-11(18), isdnDChannelProcedure-12(19), x29Rerouting-13(20), ethernetBridgeAndIpRouterFunctions-14(21), dlcMtrFrad-15(22), compressionProcedure-16(23), dlmFunction-17(24), configurationFunction-18(25), lmiFunction-19(26), ppp-1A(27), frameRelaySna-1B(28), tokenRing-1C(29)  

fmeFamStoredEventsCount 2.1.866.20.10.5.2.1.2
The value of this object how many events are stored for this family.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

fmeFamStoredEventsCommand 2.1.866.20.10.5.2.1.3
The value of this object permits, when it is set to 'delete', to destroy the stored events of this family. The equipment answers always with the value 'ready' to a GetRequest on this object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), delete(2)  

fmeEventTable 2.1.866.20.10.5.3
This table contains the stored outstanding events.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmeEventEntry

fmeEventEntry 2.1.866.20.10.5.3.1
An entry of fmeEventTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmeEventEntry  

fmeEvtFamilyId 2.1.866.20.10.5.3.1.1
The value of this object identifies one and only one family. This is the family this outstanding event belongs to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER troubleReport-00(1), management-01(2), synchronousSignalling-02(3), x25SynchronousProcedure-03(4), synchronousLink-04(5), linePhysicalLevel-05(6), asynchronousProtocolLevel-06(7), asynchronousCommandSyntax-07(8), asynchronousSemanticLevel-08(9), sdlcProcedure-09(10), vipProcedure-0A(11), tvipFradBscProcedure-0B(12), dlcBscProcedure-0C(13), mlp-0D(14), pstnProcedure-0E(15), securizedVcEsv-0F(16), securizedVcN4-10(17), securizedVcIr-11(18), isdnDChannelProcedure-12(19), x29Rerouting-13(20), ethernetBridgeAndIpRouterFunctions-14(21), dlcMtrFrad-15(22), compressionProcedure-16(23), dlmFunction-17(24), configurationFunction-18(25), lmiFunction-19(26), ppp-1A(27), frameRelaySna-1B(28), tokenRing-1C(29)  

fmeEvtEventIndex 2.1.866.20.10.5.3.1.2
The value of this object identifies one and only one outstanding event of this familty.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

fmeEvtEventType 2.1.866.20.10.5.3.1.3
The value of this object is the event type. See the management function manual for more information on the description of the events.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

fmeEvtTime 2.1.866.20.10.5.3.1.4
The value of this object is the value of sysUpTime when this event was stored.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fmeEvtLineId 2.1.866.20.10.5.3.1.5
The value of this object is the identifier of the line where this event takes place. The value '255' means 'general' (i.e., not a particular line).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmeEvtData 2.1.866.20.10.5.3.1.6
The value of this object contains additional data for this event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fmeTrapInfo 2.1.866.20.10.5.4
OBJECT IDENTIFIER    

fmeTrapLineId 2.1.866.20.10.5.4.1
The value of this object is the identifier of the line where the event takes place. The value '255' means 'general' (i.e., not a particular line). This object is only used in a Trap PDU and is not accessible by GET requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmeTrapFamilyId 2.1.866.20.10.5.4.2
The value of this object identifies one and only one family. This is the family the outstanding event belongs to. This object is only used in a Trap PDU and is not accessible by GET requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER troubleReport-00(1), management-01(2), synchronousSignalling-02(3), x25SynchronousProcedure-03(4), synchronousLink-04(5), linePhysicalLevel-05(6), asynchronousProtocolLevel-06(7), asynchronousCommandSyntax-07(8), asynchronousSemanticLevel-08(9), sdlcProcedure-09(10), vipProcedure-0A(11), tvipFradBscProcedure-0B(12), dlcBscProcedure-0C(13), mlp-0D(14), pstnProcedure-0E(15), securizedVcEsv-0F(16), securizedVcN4-10(17), securizedVcIr-11(18), isdnDChannelProcedure-12(19), x29Rerouting-13(20), ethernetBridgeAndIpRouterFunctions-14(21), dlcMtrFrad-15(22), compressionProcedure-16(23), dlmFunction-17(24), configurationFunction-18(25), lmiFunction-19(26), ppp-1A(27), frameRelaySna-1B(28)  

fmeTrapEventType 2.1.866.20.10.5.4.3
The value of this object is the event type. See the management function manual for more information on the description of the events. This object is only used in a Trap PDU and is not accessible by GET requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmeTrapEventData 2.1.866.20.10.5.4.4
The value of this object contains additional data for the event. This object is only used in a Trap PDU and is not accessible by GET requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fmStat 2.1.866.20.10.10
OBJECT IDENTIFIER    

fmStatControl 2.1.866.20.10.10.1
OBJECT IDENTIFIER    

fmsCtrlStatus 2.1.866.20.10.10.1.1
The value of this object indicates the processing state of the statistics. The value 'notInProgress' indicates that there is only a SNMP access at the management function. The value 'InProgress' indicates that there is an access to the management function which is not a SNMP access.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inProgress(1), notInProgress(2)  

fmsCtrlSumming 2.1.866.20.10.10.1.2
The value of this object is the summing mode of the statistics. The value 'infinite' indicates that the statistics are calculated since the last counters reset. With the value 'notInfinite', the statistics are calculated on the configurable period, which there is an automatic counters reset beyond. The default value is 'notInfinite'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER infinite(1), notInfinite(2)  

fmsCtrlCountersCommand 2.1.866.20.10.10.1.3
The value of this object permits, when it is set to 'reset', to re-initialize all the counters except those in fmStatEthOutputTrafficTable, fmStatEthInputTrafficTable and fmStatEthManagementTable. The equipment answers always with the value 'ready' to a GetRequest on this object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), reset(2)  

fmsCtrlResetTime 2.1.866.20.10.10.1.4
The value of this object is the value of sysUpTime when the counters were re-initialized by a 'reset' command (see fmsCtrlCountersCommand).
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fmStatGlobal 2.1.866.20.10.10.10
OBJECT IDENTIFIER    

fmsGlobInitBuffCount 2.1.866.20.10.10.10.1
The value of this object is the total number of the buffers created when initializing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsGlobFreeBuffCount 2.1.866.20.10.10.10.2
The value of this object is the total number of the free buffers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsGlobCpuA 2.1.866.20.10.10.10.3
The value of this object is the maximum instant load of the CPU A on all the modules.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsGlobCpuB 2.1.866.20.10.10.10.4
The value of this object is the maximum instant load of the CPU B on all the modules.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsGlobVcInUseCount 2.1.866.20.10.10.10.5
The value of this object is the number of the virtual circuits established.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsGlobGeneratorsInUseCount 2.1.866.20.10.10.10.6
The value of this object is the number of the busy traffic generators.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsGlobCompressOctetGain 2.1.866.20.10.10.10.7
The value of this object is the total gain, in volume (in bytes), generated by the compression/scrambling function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsGlobCompressBillGain 2.1.866.20.10.10.10.8
The value of this object is the total gain, in billing (in segments), generated by the compression/scrambling function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsGlobLanCpu 2.1.866.20.10.10.10.9
The value of this object is the transputer CPU load.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsGlobCongCpuLostBlocks 2.1.866.20.10.10.10.10
Nb de blocs de 0 a N octets rejetes sur congestion CPU (N = 160 en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsGlobCongRamLostBlocks 2.1.866.20.10.10.10.11
Nb de blocs de 0 a N octets rejetes sur congestion memoire (N = 160 en v2.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatInputTraffic 2.1.866.20.10.10.11
OBJECT IDENTIFIER    

fmsInputDataPktsCounter 2.1.866.20.10.10.11.1
The value of this object is the total number of the data packets received by the internal switch from the beginning of the collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsInputDataBytesCounter 2.1.866.20.10.10.11.2
The value of this object is the total number of the data bytes received by the internal switch from the beginning of the collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsInputIntrPktsCounter 2.1.866.20.10.10.11.3
The value of this object is the total number of the interrupt packets received by the internal switch from the beginning of the collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsInputReinitPktsCounter 2.1.866.20.10.10.11.4
The value of this object is the total number of the reset packets received by the internal switch from the beginning of the collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsInputCallPktsCounter 2.1.866.20.10.10.11.5
The value of this object is the total number of the call packets received by the internal switch from the beginning of the collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsInputCallConfPktsCounter 2.1.866.20.10.10.11.6
The value of this object is the total number of the call confirmation received and successfully processed by the internal switch from the beginning of the collection period. This object is therefore the number of the virtual circuits established from the beginning of the collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatLineTable 2.1.866.20.10.10.12
This table contains the information about the statistics by line.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatLineEntry

fmStatLineEntry 2.1.866.20.10.10.12.1
An entry of fmStatLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatLineEntry  

fmsLineId 2.1.866.20.10.10.12.1.1
The value of this object is the one line identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..55  

fmsLineState 2.1.866.20.10.10.12.1.2
The value of this object is the state of this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(2), disconnectedByDiag(3), layer1Up(1), layer2Up(4), layer3Up(5)  

fmsLineLcInUseCount 2.1.866.20.10.10.12.1.3
The value of this object is the total number of the busy logical channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsLineReinitsCounter 2.1.866.20.10.10.12.1.4
The value of this object is the total number of the resets of this line from the beginning of the collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsLineIncidentsCounter 2.1.866.20.10.10.12.1.5
The value of this object is the total number of the incidents of this line from the beginning of the collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmsLineInputOctetsCounter 2.1.866.20.10.10.12.1.6
The value of this object is the total number of the bytes received over this line from the beginning of the collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsLineOutputOctetsCounter 2.1.866.20.10.10.12.1.7
The value of this object is the total number of bytes sent over this line from the beginning of the collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsLineType 2.1.866.20.10.10.12.1.20
The value of this object indicates the type of this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER x25Synchronous(1), asynchronous(2), asynchronousSdlc(4), synchronousVipCharacter(6), synchronousBscTransparentCharacter(7), characterSynchronousBsc3270Or2780-3780(8), isdnDChannel(14), isdnBChannelWithSignalling(15), isdnBChannelWithoutSignalling(16), isdnDChannelWithPll(17), frameRelayTypeTransit(19), hdlc(20), frameRelaySubscriber(21), lanConnection(23), lanIpRouter(27), lanBridgeOrIpRouter(28), asynchronousX28(30), synchronousPpp(39), asynchronousPpp(40), moduleLink(50), unitLink(51)  

fmsLineTestState 2.1.866.20.10.10.12.1.21
The value of this object indicates the test state of this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmStatSignalTable 2.1.866.20.10.10.13
This table contains the information about the lines signals.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatSignalEntry

fmStatSignalEntry 2.1.866.20.10.10.13.1
An entry of fmStatSignalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatSignalEntry  

fmsSigPhysPortId 2.1.866.20.10.10.13.1.1
The value of this object is the one physical line identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsSigState 2.1.866.20.10.10.13.1.2
The value of this object indictates the state of this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2)  

fmsSigDceOrDte 2.1.866.20.10.10.13.1.3
The value of this object indicates whether the equipment is DTE or DCE for this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dce(1), dte(2)  

fmsSig105 2.1.866.20.10.10.13.1.4
The value of this object indicates the state of the signal 105 on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsSig106 2.1.866.20.10.10.13.1.5
The value of this object indicates the state of the signal 106 on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsSig107 2.1.866.20.10.10.13.1.6
The value of this object indicates the state of the signal 107 on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsSig108 2.1.866.20.10.10.13.1.7
The value of this object indicates the state of the signal 108 on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsSig109 2.1.866.20.10.10.13.1.8
The value of this object indicates the state of the signal 109 on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsSig111 2.1.866.20.10.10.13.1.9
The value of this object indicates the state of the signal 111 on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsSig125 2.1.866.20.10.10.13.1.10
The value of this object indicates the state of the signal 125 on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsSig140 2.1.866.20.10.10.13.1.11
The value of this object indicates the state of the signal 140 on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsSig141 2.1.866.20.10.10.13.1.12
The value of this object indicates the state of the signal 141 on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsSig142 2.1.866.20.10.10.13.1.13
The value of this object indicates the state of the signal 142 on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsSigSyn 2.1.866.20.10.10.13.1.14
The value of this object indicates the state of the signal SYN on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER undefined(1), off(2), on(3)  

fmStatLinesSummary 2.1.866.20.10.10.15
OBJECT IDENTIFIER    

fmsLinesSummState 2.1.866.20.10.10.15.1
This object indicates the state of each line of the equipment with the following format,. each line using three octets (i.e., 24 bits) : bit 0 : physical level (0 = down, 1 = up), bit 1: level 3 (0 = down, 1 = up), bits 2 to 8 : protocol (1 = X25 synchronous, 2 = asynchronous, 4 = asynchronous SDLC, 6 = asynchronous VIP character, 7 = BSC Transparent character, 8 = asynchronous on BSC 3270 or 2780/3780, 14 = ISDN D-Channel with or without PLL, 15 = ISDN B-Channel with signalling, 16 = ISDN B-Channel without signalling, 19 = Frame Relay transit or FR-TE, 20 = HDLC-T, 21 = Frame Relay subscriber, FRA, 23 = Ethernet, 30 = asynchronous X28+), bits 9 to 20 : number of active logical channels (0 to 4095), bits 20 to 23 : unused.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..80)  

fmStatStateTable 2.1.866.20.10.10.20
This table contains the information about the type and the state of the lines.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatStateEntry

fmStatStateEntry 2.1.866.20.10.10.20.1
An entry of fmStatStateTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatStateEntry  

fmsStateLine 2.1.866.20.10.10.20.1.1
The value of this object is the one line identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..55  

fmsStateLineType 2.1.866.20.10.10.20.1.2
The value of this object indicates the type of this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER x25Synchronous(1), asynchronous(2), asynchronousSdlc(4), synchronousVipCharacter(6), synchronousBscTransparentCharacter(7), characterSynchronousBsc3270Or2780-3780(8), isdnDChannel(14), isdnBChannelWithSignalling(15), isdnBChannelWithoutSignalling(16), isdnDChannelWithPll(17), frameRelayTypeTransit(19), hdlc(20), frameRelaySubscriber(21), lanConnection(23), lanIpRouter(27), lanBridgeOrIpRouter(28), asynchronousX28(30), synchronousPpp(39), asynchronousPpp(40), moduleLink(50), unitLink(51)  

fmsStateOsiState 2.1.866.20.10.10.20.1.3
The value of this object indicates the state and the ISO layer of this line. If this line is up, the value indicated is the ISO layer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), layer1Up(2), layer2Up(3), layer3Up(4)  

fmsStateTestState 2.1.866.20.10.10.20.1.4
The value of this object indicates the test state of this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notUnderTest(1), lineDisconnectedByTelemaintenance(2), underTest(3)  

fmsStateMlpTrunkMainLine 2.1.866.20.10.10.20.1.5
The value of this object indicates if this line is the main line of a MLP trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fmsStateMlpTrunkNumber 2.1.866.20.10.10.20.1.6
The value of this object is the identifier of the MLP trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmsStateMlpTrunkState 2.1.866.20.10.10.20.1.7
The value of this object is the MLP trunk state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2)  

fmStatMlpTable 2.1.866.20.10.10.30
This table contains the information about the MLP trunks.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatMlpEntry

fmStatMlpEntry 2.1.866.20.10.10.30.1
An entry of fmStatMlpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatMlpEntry  

fmsMlpTrunkNumber 2.1.866.20.10.10.30.1.1
The value of this object is the identifier of the MLP trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmsMlpLineId 2.1.866.20.10.10.30.1.2
The value of this object is the one line identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsMlpLineType 2.1.866.20.10.10.30.1.3
The value of this object indicates if this line is the main line of this MLP trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER mainDown(1), mainUp(2), secondaryDown(3), secondaryUp(4)  

fmStatEthernet 2.1.866.20.10.10.40
OBJECT IDENTIFIER    

fmStatEthernetTable 2.1.866.20.10.10.40.1
This table contains the general information about the Ethernet physical ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatEthernetEntry

fmStatEthernetEntry 2.1.866.20.10.10.40.1.1
An entry of fmStatEthernetTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatEthernetEntry  

fmsEthLineId 2.1.866.20.10.10.40.1.1.1
The value of this object is the identifier of one physical port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsEthPhysAddr 2.1.866.20.10.10.40.1.1.2
The value of this object is the MAC address of the equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

fmsEthOperStatus 2.1.866.20.10.10.40.1.1.3
The value of this object is the state of the LAN function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2)  

fmsEthInterface 2.1.866.20.10.10.40.1.1.4
The value of this object is the ethernet connector type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet10base5(1), ethernet10BaseT(2), ethernetAuto(3)  

fmsEthAutoPortSelection 2.1.866.20.10.10.40.1.1.20
The value of this object indicates whether the selection of the LAN port is automatic or not.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsEthPolarityCorrection 2.1.866.20.10.10.40.1.1.21
The value of this object indicates the state of the polarity spontaneous correction.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsEthPolarityInversion 2.1.866.20.10.10.40.1.1.22
The value of this object indicates if there is inversion of the polarity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fmsEthLinkIntegrity 2.1.866.20.10.10.40.1.1.23
The value of this object indicates the state of the link integrity function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), down(2), up(3)  

fmsEthTestLoopback 2.1.866.20.10.10.40.1.1.24
The value of this object indicates if the loopback test is used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsEthJabber 2.1.866.20.10.10.40.1.1.25
The value of this object is the state of the bus taking time control function (Jabber).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsEthTestMode 2.1.866.20.10.10.40.1.1.26
The value of this object is the mode of the test. The value 'continousSending' indicates that frames are sent continously during the test. The value 'standby' indicates that no frames are sent during the test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), continousSending(2), standby(3)  

fmsEthTdrState 2.1.866.20.10.10.40.1.1.27
The value of this object (Time Domain Reflectometry) indicates the problem type of the connectors system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), transceiverProblem(2), openCircuit(3), shortCircuit(4)  

fmsEthTdrLoc 2.1.866.20.10.10.40.1.1.28
The value of this object (Time Domain Reflectometry) indicates the tracing of connectors system problem. The value '2047' is not significant.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2047  

fmsEthUpTime 2.1.866.20.10.10.40.1.1.29
The value of this object is the time elapsing since the last start-up of the LAN interface. When the equipment starts, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fmStatEthInputTrafficTable 2.1.866.20.10.10.40.2
This table contains the information about the statistics, in reception, of a LAN line. The values of all this counters are not reseted by the command 'reset' of fmsCtrlCountersCommand.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatEthInputTrafficEntry

fmStatEthInputTrafficEntry 2.1.866.20.10.10.40.2.1
An entry of fmStatEthInputTrafficTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatEthInputTrafficEntry  

fmsEthInLineId 2.1.866.20.10.10.40.2.1.1
The value of this object is the one line identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsEthInOctetsCounter 2.1.866.20.10.10.40.2.1.2
The value of this object is the number of the bytes received over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInPktsCounter 2.1.866.20.10.10.40.2.1.3
The value of this object is the number of the frames received over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInNoErrCounter 2.1.866.20.10.10.40.2.1.4
The value of this object is the number of the frames received with no error over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInUcastPktsCounter 2.1.866.20.10.10.40.2.1.5
The value of this object is the number of the frames received over this line and correctly sent to the upper layer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInAlignmentErrorsCounter 2.1.866.20.10.10.40.2.1.20
The value of this object is the number of the frames received with an error of alignment (number of bits not multiple of 8) over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInFCSErrorsCounter 2.1.866.20.10.10.40.2.1.21
The value of this object is the number of the frames received with an error of CRC over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInPktsTooLongsCounter 2.1.866.20.10.10.40.2.1.22
The value of this object is the number of the frames received with a length too long over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInPktsTooShortsCounter 2.1.866.20.10.10.40.2.1.23
The value of this object is the number of the frames received with a length too short over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInErrOutOfResourcesCounter 2.1.866.20.10.10.40.2.1.24
The value of this object is the number of the frames received with an error of resources too short over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInErrDmaOverrunCounter 2.1.866.20.10.10.40.2.1.25
The value of this object is the number of the frames received with the error 'DMA overrun' (no reply when expected by the memory bus to a DMA cycle) over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInErrCollCounter 2.1.866.20.10.10.40.2.1.26
The value of this object is the number of the frames received with the error 'receive collision' (frames received but invalided because of a collision detection during the reception) over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthInErrOverFlowCounter 2.1.866.20.10.10.40.2.1.27
The value of this object is the number of the frames received over this line and not sent to the upper layer because of the resources overflow.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatEthOutputTrafficTable 2.1.866.20.10.10.40.3
This table contains the information about the statistics, in sending, of one LAN line. The values of all this counters are not reseted by the command 'reset' of fmsCtrlCountersCommand.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatEthOutputTrafficEntry

fmStatEthOutputTrafficEntry 2.1.866.20.10.10.40.3.1
An entry of fmStatEthOutputTrafficTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatEthOutputTrafficEntry  

fmsEthOutLineId 2.1.866.20.10.10.40.3.1.1
The value of this object is the one line identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsEthOutOctetsCounter 2.1.866.20.10.10.40.3.1.2
The value of this object is the number of the bytes sent over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutPktsCounter 2.1.866.20.10.10.40.3.1.3
The value of this object is the number of the frames sent over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutNoErrCounter 2.1.866.20.10.10.40.3.1.4
The value of this object is the number of the frames sent without error over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutSingleCollisionFramesCounter 2.1.866.20.10.10.40.3.1.5
The value of this object is the number of the frames sent after one collision over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutMultipleCollisionFramesCounter 2.1.866.20.10.10.40.3.1.6
The value of this object is the number of the frames sent after two collisions or more over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutDeferredTransmissionsCounter 2.1.866.20.10.10.40.3.1.7
The value of this object is the number of the frames sent late over this line because the ethernet bus is busy.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutSQETestErrorsCounter 2.1.866.20.10.10.40.3.1.20
The value of this object is the number of the frames sent with error of no heartbeat over this line. The heartbeat function of the ethernet transmitter is used to indicate to the LAN driver the status of its collision detector. If following a transmission, the transmitter does not send the SQE signal of the heartbeat function to the equipment, then the frame is considered to be sent with 'no heartbeat' error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutLateCollisionsCounter 2.1.866.20.10.10.40.3.1.21
The value of this object is the number of the frames not sent because of the error 'late collision' (collision detection after the end of the slot time) over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutExcessiveCollisionsCounter 2.1.866.20.10.10.40.3.1.22
The value of this object is the number of the frames not sent because of the collisions detections at all the attempts over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutCarrierSenseErrorsCounter 2.1.866.20.10.10.40.3.1.23
The value of this object is the number of the frames not sent because of the error 'no carrier sense' over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutErrExcdDelayCounter 2.1.866.20.10.10.40.3.1.24
The value of this object is the number of the frames not sent over this line because the bus is busy during a long time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutErrCtsLossCounter 2.1.866.20.10.10.40.3.1.25
The value of this object is the number of the frames not sent over this line because of the loss of the CTS (Clear To Send) signal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthOutErrDmaUnderrunCounter 2.1.866.20.10.10.40.3.1.26
The value of this object is the number of the frames not sent over this line because of the error 'DMA underrun' (no reply when expected by the memory bus to a DMA cycle).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatEthManagementTable 2.1.866.20.10.10.40.4
This table contains the information about the monitoring, the reset and the filtering for each port. The values of all this counters are not reseted by the command 'reset' of fmsCtrlCountersCommand.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatEthManagementEntry

fmStatEthManagementEntry 2.1.866.20.10.10.40.4.1
An entry of fmStatEthManagementTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatEthManagementEntry  

fmsEthManLineId 2.1.866.20.10.10.40.4.1.1
The value of this object is the one line identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsEthManSupervisionOkCounter 2.1.866.20.10.10.40.4.1.2
The value of this object is the number of the OK supervision frames over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthManSupervisionNokCounter 2.1.866.20.10.10.40.4.1.3
The value of this object is the number of the not OK supervision frames over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthManInputResetCounter 2.1.866.20.10.10.40.4.1.4
The value of this object is the number of the reception resets over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthManFilterPermitCounter 2.1.866.20.10.10.40.4.1.5
The value of this object is the number of the frames accepted by the bridge filtering over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsEthManFilterDenyCounter 2.1.866.20.10.10.40.4.1.6
The value of this object is the number of the frames refused by the bridge filtering over this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatWanConnectionsTable 2.1.866.20.10.10.45
This table contains the information about the WAN connections.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatWanConnectionsEntry

fmStatWanConnectionsEntry 2.1.866.20.10.10.45.1
An entry of fmStatWanConnectionsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatWanConnectionsEntry  

fmsWanConnId 2.1.866.20.10.10.45.1.1
The value of this object is the one SLL (Switched Logical Link) identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmsWanConnRemoteAddr 2.1.866.20.10.10.45.1.2
The value of this object is the X121 address of the remote equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fmsWanConnEncapsulation 2.1.866.20.10.10.45.1.3
The value of this object indicates the encapsulation type over this SLL (Switched Logical Link).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rilBridge(9), ip(20)  

fmsWanConnStatus 2.1.866.20.10.10.45.1.5
The value of this object is the state of this SLL (Switched Logical Link).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2)  

fmsWanConnGrouping 2.1.866.20.10.10.45.1.6
The value of this object indicates if the grouping function is used over this SLL (Switched Logical Link).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), multiFrames(3), grouping(2)  

fmsWanConnLocalSbNumber 2.1.866.20.10.10.45.1.7
The value of this object is the subscriber local number AB (in the DNIC ZO AB plan) of the LAN coupling function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

fmsWanConnInPktsCounter 2.1.866.20.10.10.45.1.20
The value of this object is the number of frames received over this SLL (Switched Logical Link).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsWanConnInErrPktsCounter 2.1.866.20.10.10.45.1.21
The value of this object is the number of frames lost because they are erroneous over this SLL (Switched Logical Link).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsWanConnInOctetsCounter 2.1.866.20.10.10.45.1.22
The value of this object is the number of bytes received over this SLL (Switched Logical Link).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsWanConnOutPktsCounter 2.1.866.20.10.10.45.1.30
The value of this object is the number of frames sent over this SLL (Switched Logical Link).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsWanConnOutOctetsCounter 2.1.866.20.10.10.45.1.31
The value of this object is the number of bytes sent over this SLL (Switched Logical Link).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatRemoteVirtualPorts 2.1.866.20.10.10.46
OBJECT IDENTIFIER    

fmStatRvpConnectionsTable 2.1.866.20.10.10.46.1
This table contains the information about the remote virtual ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatRvpConnectionsEntry

fmStatRvpConnectionsEntry 2.1.866.20.10.10.46.1.1
An entry of fmStatRvpConnectionsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatRvpConnectionsEntry  

fmsRvpConnRemoteAddr 2.1.866.20.10.10.46.1.1.2
The value of this object is the X121 address of the remote equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fmsRvpConnEncapsulation 2.1.866.20.10.10.46.1.1.3
The value of this object indicates the encapsulation type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER multiplexing(1), bridge(10), bridgeSpecific(11), ip(20), ipx(30), ipxSpecific(31), clnp(40)  

fmsRvpConnId 2.1.866.20.10.10.46.1.1.4
The value of this object is the one connection identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmsRvpConnStatus 2.1.866.20.10.10.46.1.1.5
The value of this object is the state of this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2)  

fmsRvpConnGrouping 2.1.866.20.10.10.46.1.1.6
The value of this object indicates if the grouping function is used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmsRvpConnLocalSbNumber 2.1.866.20.10.10.46.1.1.7
The value of this object is the subscriber local number AB (in the DNIC ZO AB plan) of this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

fmsRvpConnInPktsCounter 2.1.866.20.10.10.46.1.1.20
The value of this object is the number of frames received over this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsRvpConnInErrPktsCounter 2.1.866.20.10.10.46.1.1.21
The value of this object is the number of frames lost because they are erroneous over this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsRvpConnInOctetsCounter 2.1.866.20.10.10.46.1.1.22
The value of this object is the number of bytes received over this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsRvpConnOutPktsCounter 2.1.866.20.10.10.46.1.1.30
The value of this object is the number of frames sent over this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsRvpConnOutOctetsCounter 2.1.866.20.10.10.46.1.1.31
The value of this object is the number of bytes sent over this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatBridge 2.1.866.20.10.10.50
OBJECT IDENTIFIER    

fmsBridgeState 2.1.866.20.10.10.50.1
The value of this object is the state of the bridging function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), transparentBridge(2)  

fmStatBrdgTraffic 2.1.866.20.10.10.50.18
OBJECT IDENTIFIER    

fmsBrdgTrafInPktsCounter 2.1.866.20.10.10.50.18.1
The value of this object is the number of the frames received by the bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsBrdgTrafOutPktsCounter 2.1.866.20.10.10.50.18.20
The value of this object is the number of the frames sent by the bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsBrdgTrafOutBroadcastPktsCounter 2.1.866.20.10.10.50.18.21
The value of this object is the number of the data frames diffusions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsBrdgTrafInServCounter 2.1.866.20.10.10.50.18.50
The value of this object is the number of the RIL service frames received by the bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsBrdgTrafOutServCounter 2.1.866.20.10.10.50.18.51
The value of this object is the number of the RIL service frames sent by the bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsBrdgTrafOutBroadcastServCounter 2.1.866.20.10.10.50.18.52
The value of this object is the number of the service frames diffusions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatIpRouter 2.1.866.20.10.10.51
OBJECT IDENTIFIER    

fmsIpRouterState 2.1.866.20.10.10.51.1
The value of this object is the state of the IP routing function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmStatIpTraffic 2.1.866.20.10.10.51.18
OBJECT IDENTIFIER    

fmsIpTrafInReceivesCounter 2.1.866.20.10.10.51.18.1
The value of this object is the number of the IP datagrams received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpTrafOutRequestsCounter 2.1.866.20.10.10.51.18.2
The value of this object is the number of the IP datagrams sent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpTrafInOctetsCounter 2.1.866.20.10.10.51.18.3
The value of this object is the number of the bytes received with the IP protocol.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpTrafOutOctetsCounter 2.1.866.20.10.10.51.18.4
The value of this object is the number of the bytes sent with the IP protocol.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpTrafInUnknownProtosCounter 2.1.866.20.10.10.51.18.5
The value of this object is the number of the IP datagrams received and lost because of an unknown protocol.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpTrafNoRoutesCounter 2.1.866.20.10.10.51.18.6
The value of this object is the number of the IP datagrams received and lost because of an impossible routing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpTrafInHdrErrorsCounter 2.1.866.20.10.10.51.18.7
The value of this object is the number of the IP datagrams received and lost because they are erroneous.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpTrafOutForwDatagramsCounter 2.1.866.20.10.10.51.18.8
The value of this object is the number of the IP datagrams received and correctly routed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpTrafOutForwDefRouteCounter 2.1.866.20.10.10.51.18.9
The value of this object is the number of the IP datagrams received and routed on the default route.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpTrafIcmpOutMsgsCounter 2.1.866.20.10.10.51.18.10
The value of this object is the number of the ICMP datagrams sent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpTrafIcmpInMsgsCounter 2.1.866.20.10.10.51.18.11
The value of this object is the number of the ICMP datagrams received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatIpLanTraffic 2.1.866.20.10.10.51.19
OBJECT IDENTIFIER    

fmsIpLanIpAddr 2.1.866.20.10.10.51.19.1
fmStatIpLanTraffic 0 The value of this object is the IP address of the LAN interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmsIpLanNetMask 2.1.866.20.10.10.51.19.2
The value of this object is the sub-network mask of the LAN interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmsIpLanOutRequestsCounter 2.1.866.20.10.10.51.19.3
The value of this object is the number of the IP datagrams sent on the LAN interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpLanInReceivesCounter 2.1.866.20.10.10.51.19.4
The value of this object is the number of the IP datagrams received on the LAN interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpLanOutOctetsIpCounter 2.1.866.20.10.10.51.19.5
The value of this object is the number of the bytes sent with the IP protocol on the LAN interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpLanInOctetsIpCounter 2.1.866.20.10.10.51.19.6
The value of this object is the number of the bytes received with the IP protocol on the LAN interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpLanNoRoutesCounter 2.1.866.20.10.10.51.19.7
The value of this object is the number of the IP datagrams received and lost because of impossible routing, on the LAN interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpLanInHdrErrorsCounter 2.1.866.20.10.10.51.19.8
The value of this object is the number of the IP datagrams received and lost because of they are erroneous, on the LAN interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsIpLanArpFailedCounter 2.1.866.20.10.10.51.19.9
The value of this object is the number of the not solved ARP request, on the LAN interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatIpClusterStateTable 2.1.866.20.10.10.51.25
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatIpClusterStateEntry

fmStatIpClusterStateEntry 2.1.866.20.10.10.51.25.1
An entry of fmStatIpClusterStateTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatIpClusterStateEntry  

fmsIpCluVpId 2.1.866.20.10.10.51.25.1.1
VP id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fmsIpCluClusterNumber 2.1.866.20.10.10.51.25.1.2
Cluster number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmsIpCluVirtualIpAddress 2.1.866.20.10.10.51.25.1.3
Virtual IP Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmsIpCluOperStatus 2.1.866.20.10.10.51.25.1.4
Operation State
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), backup(2), master(3)  

fmsIpCluAdminStatus 2.1.866.20.10.10.51.25.1.5
Administration State
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmsIpCluLastChange 2.1.866.20.10.10.51.25.1.6
Time from the Last Change
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fmStatFrameRelay 2.1.866.20.10.10.60
OBJECT IDENTIFIER    

fmsFrSwitch 2.1.866.20.10.10.60.1
OBJECT IDENTIFIER    

fmsFrSwDataLinkConnEstablished 2.1.866.20.10.10.60.1.1
Nb de connexions FR etablis (svc-svc, pvc-svc, proto-svc).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrSwBookingInputThrouhput 2.1.866.20.10.10.60.1.10
Debit reserve (somme des CIR abonnes vers reseau).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrSwOverBookingThrouhput 2.1.866.20.10.10.60.1.12
Debit reserve par les SVC en surbooking.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrLogicalPort 2.1.866.20.10.10.60.2
OBJECT IDENTIFIER    

fmsFrLpLogPortTable 2.1.866.20.10.10.60.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsFrLpLogPortEntry

fmsFrLpLogPortEntry 2.1.866.20.10.10.60.2.1.1
An entry of fmsFrLpLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsFrLpLogPortEntry  

fmsFrLpLogPortId 2.1.866.20.10.10.60.2.1.1.1
LP id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmsFrLpInterfaceType 2.1.866.20.10.10.60.2.1.1.3
Type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER frCe(1), frTe(2), frSe(3)  

fmsFrLpNumPlan 2.1.866.20.10.10.60.2.1.1.11
The value of this object identifies the network address numbering plan for this logical port. The network address is the object ifPhysAddress. The value none implies that there is no ifPhysAddress. The SNMP agent will return an octet string of zero length for ifPhysAddress. The value other means that an address has been assigned to this interface, but the numbering plan is not enumerated here.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), e164(2), x121(3), none(4)  

fmsFrLpAddrDlciLen 2.1.866.20.10.10.60.2.1.1.15
The value of this object identifies the Q.922 Address field length and DLCI length for this logical port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER twoOctets10Bits(1), threeOctets10Bits(2), threeOctets16Bits(3), fourOctets17Bits(4), fourOctets23Bits(5)  

fmsFrLpVcSigProtocol 2.1.866.20.10.10.60.2.1.1.16
The value of this object identifies the Local In-Channel Signaling Protocol that is used for this frame relay logical port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), lmi(2), ansiT1617D(3), ansiT1617B(4), itutQ933A(5), itutQ933(6)  

fmsFrLpIncomingTable 2.1.866.20.10.10.60.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsFrLpIncomingEntry

fmsFrLpIncomingEntry 2.1.866.20.10.10.60.2.2.1
An entry of fmsFrLpIncomingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsFrLpIncomingEntry  

fmsFrLpInLogPortId 2.1.866.20.10.10.60.2.2.1.1
LP id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmsFrLpInOctets 2.1.866.20.10.10.60.2.2.1.2
The number of received octets. This counter only counts octets from the beginning of the frame relay header field to the end of user data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpInFrames 2.1.866.20.10.10.60.2.2.1.3
The number of received unerrored, unicast frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpInErrors 2.1.866.20.10.10.60.2.2.1.4
The number of received frames that are discarded, because of an error. Possible errors can be the following: the frame relay frames were too long or were too short.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpInFrHeaderErrors 2.1.866.20.10.10.60.2.2.1.5
The number of received frames that are discarded, because of an error. Possible errors can be the following: the frames had an invalid or unrecognized DLCI values, or incorrect header values.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpInFecnFrames 2.1.866.20.10.10.60.2.2.1.10
Number of frames received indicating forward congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpInBecnFrames 2.1.866.20.10.10.60.2.2.1.12
Number of frames received indicating backward congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpInExcessFrames 2.1.866.20.10.10.60.2.2.1.15
Only on FR-CE or FR-TE logical ports : The number of frames received by the equipment (ingress) for this logical port which were treated as excess traffic. Frames which are sent to the equipment with DE set to zero are treated as excess when more than Bc bits are submitted to the equipment during the Committed Information Rate Measurement Interval (Tc). Excess traffic may or may not be discarded at the ingress if more than Bc + Be bits are submitted to the equipment during Tc. Traffic discarded at the ingress is not recorded in this object. Frames which are sent to the equipement with DE set to one are also treated as excess traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpInDiscards 2.1.866.20.10.10.60.2.2.1.16
Only on FR-CE or FR-TE logical ports : The number of frames received by the equipment (ingress) that were discarded due to traffic enforcement for this logical port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpOutgoingTable 2.1.866.20.10.10.60.2.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsFrLpOutgoingEntry

fmsFrLpOutgoingEntry 2.1.866.20.10.10.60.2.3.1
An entry of fmsFrLpOutgoingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsFrLpOutgoingEntry  

fmsFrLpOutLogPortId 2.1.866.20.10.10.60.2.3.1.1
LP id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmsFrLpOutOctets 2.1.866.20.10.10.60.2.3.1.2
The number of transmitted octets. This counter only counts octets from the beginning of the frame relay header field to the end of user data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpOutFrames 2.1.866.20.10.10.60.2.3.1.3
The number of frames sent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpOutFecnFrames 2.1.866.20.10.10.60.2.3.1.10
Number of frames sent indicating forward congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpOutLocalCongFecnFrames 2.1.866.20.10.10.60.2.3.1.11
Number of frames sent indicating forward congestion due to traffic enforcement on this logical port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpOutBecnFrames 2.1.866.20.10.10.60.2.3.1.12
Number of frames sent indicating backward congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpOutLocalCongBecnFrames 2.1.866.20.10.10.60.2.3.1.13
Number of frames sent indicating backward congestion due to traffic enforcement on the incoming logical port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpOutLocalCongDiscards 2.1.866.20.10.10.60.2.3.1.15
The number of frames not sent by the equipment (egress) due to traffic enforcement on this logical port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpLmiTable 2.1.866.20.10.10.60.2.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsFrLpLmiEntry

fmsFrLpLmiEntry 2.1.866.20.10.10.60.2.4.1
An entry of fmsFrLpLmiTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsFrLpLmiEntry  

fmsFrLpLmiLogPortId 2.1.866.20.10.10.60.2.4.1.1
LP id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..254  

fmsFrLpLmiProced 2.1.866.20.10.10.60.2.4.1.11
The value of this object identifies the Local In-Channel Signaling Procedure that is used for this logical port. The logical port can be performing user-to-network network-side procedures, bidirectional procedures or user-to-network user-side procedures.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER u2nNet(1), bidirect(2), u2nUser(3)  

fmsFrLpLmiUserN391 2.1.866.20.10.10.60.2.4.1.12
The value of this object identifies the User-side N391 full status polling cycle value for this logical port. If the logical port is not performing user-side procedures, then this value is not significant. This object applies to Q.933 Annex A and T1.617 Annex D.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

fmsFrLpLmiUserN392 2.1.866.20.10.10.60.2.4.1.13
The value of this object identifies the User-side N392 error threshold value for this logical port. If the logical port is not performing user-side procedures, then this value is not significant. This object applies to Q.933 Annex A and T1.617 Annex D.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

fmsFrLpLmiUserN393 2.1.866.20.10.10.60.2.4.1.14
The value of this object identifies the User-side N393 monitored events count value for this logical port. If the logical port is not performing user-side procedures, then this value is not significant. This object applies to Q.933 Annex A and T1.617 Annex D.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

fmsFrLpLmiUserT391 2.1.866.20.10.10.60.2.4.1.15
The value of this object identifies the User-side T391 link integrity verification polling timer value for this logical port. If the logical port is not performing user-side procedures, then this value is not significant. This object applies to Q.933 Annex A and T1.617 Annex D.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..30  

fmsFrLpLmiNetN392 2.1.866.20.10.10.60.2.4.1.16
The value of this object identifies the Network-side N392 error threshold value (nN2 for LMI) for this logical port. If the logical port is not performing network-side procedures, then this value is not significant. This object applies to Q.933 Annex A, T1.617 Annex D and LMI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

fmsFrLpLmiNetN393 2.1.866.20.10.10.60.2.4.1.17
The value of this object identifies the Network-side N393 monitored events count value (nN3 for LMI) for this logical port. If the logical port is not performing network-side procedures, then this value is not significant. This object applies to Q.933 Annex A, T1.617 Annex D and LMI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

fmsFrLpLmiNetT392 2.1.866.20.10.10.60.2.4.1.18
The value of this object identifies the Network-side T392 polling verification timer value (nT2 for LMI) for this logical port. If the logical port is not performing network-side procedures, then this value is not significant. This object applies to Q.933 Annex A, T1.617 Annex D and LMI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..30  

fmsFrLpLmiUserLinkRelErrors 2.1.866.20.10.10.60.2.4.1.21
VCSigUserLinkRelErrors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpLmiUserProtErrors 2.1.866.20.10.10.60.2.4.1.22
VCSigUserProtErrors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpLmiUserChanInactive 2.1.866.20.10.10.60.2.4.1.23
VCSigUserChanInactive
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpLmiNetLinkRelErrors 2.1.866.20.10.10.60.2.4.1.24
VCSigNetLinkRelErrors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpLmiNetProtErrors 2.1.866.20.10.10.60.2.4.1.25
VCSigNetProtErrors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpLmiNetChanInactive 2.1.866.20.10.10.60.2.4.1.26
VCSigNetChanInactiveErrors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrLpSvcSignallingTable 2.1.866.20.10.10.60.2.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsFrLpSvcSignallingEntry

fmsFrLpSvcSignallingEntry 2.1.866.20.10.10.60.2.5.1
An entry of fmsFrLpSvcSignallingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsFrLpSvcSignallingEntry  

fmsFrLpSvcLogPortId 2.1.866.20.10.10.60.2.5.1.1
LP id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..254  

fmsFrLpSvcDlcInitialized 2.1.866.20.10.10.60.2.5.1.11
Nb de Data Link Connexion correctement initialises.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrLpSvcDlcUbr 2.1.866.20.10.10.60.2.5.1.12
Nb de DLC UBR etablies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrLpSvcDlcVbr 2.1.866.20.10.10.60.2.5.1.13
Nb de DLC VBR etablies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrLpSvcDlcVbrRt 2.1.866.20.10.10.60.2.5.1.14
Nb de DLC VBR-RT etablies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrLpSvcBookingVbrThroughput 2.1.866.20.10.10.60.2.5.1.20
Debit reserve VBR (en octets/s).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrLpSvcBookingVbrRtThroughput 2.1.866.20.10.10.60.2.5.1.21
Debit reserve VBR-RT (en octets/s).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrLpSvcOverBookingThroughput 2.1.866.20.10.10.60.2.5.1.22
Debit total avec surbooking (en octets/s).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrLpSvcBookingRate 2.1.866.20.10.10.60.2.5.1.23
Taux de reservation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrDataLinkConnection 2.1.866.20.10.10.60.3
OBJECT IDENTIFIER    

fmsFrDlcTable 2.1.866.20.10.10.60.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsFrDlcEntry

fmsFrDlcEntry 2.1.866.20.10.10.60.3.1.1
An entry of fmsFrDlcTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsFrDlcEntry  

fmsFrDlcLogPortId 2.1.866.20.10.10.60.3.1.1.1
LP Id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsFrDlcDlci 2.1.866.20.10.10.60.3.1.1.2
DLCI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

fmsFrDlcState 2.1.866.20.10.10.60.3.1.1.5
Indicates whether the particular virtual circuit is operational.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER invalid(1), active(2), inactive(3)  

fmsFrDlcRcvdSigStatus 2.1.866.20.10.10.60.3.1.1.7
PVC end point received status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER deleted(1), active(2), inactive(3), none(4)  

fmsFrDlcCos 2.1.866.20.10.10.60.3.1.1.10
COS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ubr(1), vbr(2), vbr-rt(3)  

fmsFrDlcIncomingTable 2.1.866.20.10.10.60.3.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsFrDlcIncomingEntry

fmsFrDlcIncomingEntry 2.1.866.20.10.10.60.3.2.1
An entry of fmsFrDlcIncomingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsFrDlcIncomingEntry  

fmsFrDlcInLogPortId 2.1.866.20.10.10.60.3.2.1.1
LP Id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsFrDlcInDlci 2.1.866.20.10.10.60.3.2.1.2
The value of this object is equal to the DLCI value for this Data Link Connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

fmsFrDlcInFrames 2.1.866.20.10.10.60.3.2.1.10
The number of frames received by the equipment (ingress) for this Data Link Connection. This includes any frames discarded by the equipment due to submitting more than Bc + Be data or due to any network congestion recovery procedure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcInOctets 2.1.866.20.10.10.60.3.2.1.11
The number of octets received by the equipment (ingress) for this Data Link Connection. This counter only counts octets from the beginning of the frame relay header field to the end of user data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcInDeFrames 2.1.866.20.10.10.60.3.2.1.12
The number of frames received by the equipment (ingress) with the DE bit set to (1) for this Data Link Connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcInFecnFrames 2.1.866.20.10.10.60.3.2.1.13
Number of frames received by the equipment indicating forward congestion for this Data Link Connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcInBecnFrames 2.1.866.20.10.10.60.3.2.1.14
Number of frames received by the equipment indicating backward congestion for this Data Link Connection
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcInExcessFrames 2.1.866.20.10.10.60.3.2.1.15
The number of frames received by the equipment (ingress) for this Data Link Connection which were treated as excess traffic. Frames which are sent to the equipment with DE set to zero are treated as excess when more than Bc bits are submitted to the network during the Committed Information Rate Measurement Interval (Tc). Excess traffic may or may not be discarded at the ingress if more than Bc + Be bits are submitted to the equipment during Tc. Traffic discarded at the ingress is not recorded in this object. Frames which are sent to the equipment with DE set to one are also treated as excess traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcInDiscards 2.1.866.20.10.10.60.3.2.1.16
The number of frames received by the equipment (ingress) that were discarded due to traffic enforcement for this Data Link Connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcInLostFrames 2.1.866.20.10.10.60.3.2.1.30
Nb de trames perdues dans le reseau (evalue par le mecanisme de segmentation / reassemblage).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcInLostSegments 2.1.866.20.10.10.60.3.2.1.31
Nb de segments perdus dans le reseau (evalue par le mecanisme de segmentation / reassemblage).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcOutgoingTable 2.1.866.20.10.10.60.3.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsFrDlcOutgoingEntry

fmsFrDlcOutgoingEntry 2.1.866.20.10.10.60.3.3.1
An entry of fmsFrDlcOutgoingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsFrDlcOutgoingEntry  

fmsFrDlcOutLogPortId 2.1.866.20.10.10.60.3.3.1.1
LP Id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsFrDlcOutDlci 2.1.866.20.10.10.60.3.3.1.2
The value of this object is equal to the DLCI value for this Data Link Connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

fmsFrDlcOutFrames 2.1.866.20.10.10.60.3.3.1.10
The number of frames sent by the equipment (egress) regardless of whether they are Bc or Be frames for this Data Link Connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcOutOctets 2.1.866.20.10.10.60.3.3.1.11
The number of octets sent by the equipment (egress) for this Data Link Connection. This counter only counts octets from the beginning of the frame relay header field to the end of user data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcOutFecnFrames 2.1.866.20.10.10.60.3.3.1.13
Number of frames sent by the equipment indicating forward congestion for this Data Link Connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcOutBecnFrames 2.1.866.20.10.10.60.3.3.1.14
Number of frames sent by the equipment indicating backward congestion for this Data Link Connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcOutExcessFrames 2.1.866.20.10.10.60.3.3.1.15
The number of frames sent by the equipment (egress) for this Data Link Connection which were treated as excess traffic. (The DE bit may be set to one.).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrDlcOutDiscards 2.1.866.20.10.10.60.3.3.1.16
Number of frames not sent by the equipment due to congestion for this Data Link Connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatFrLineTable 2.1.866.20.10.10.60.20
This table contains the information about the Frame Relay lines.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatFrLineEntry

fmStatFrLineEntry 2.1.866.20.10.10.60.20.1
An entry of fmStatFrLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatFrLineEntry  

fmsFrLineId 2.1.866.20.10.10.60.20.1.1
The value of this object is the one physical line identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsFrLineStatus 2.1.866.20.10.10.60.20.1.2
The value of this object indicates the state of this physical line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2)  

fmsFrLineLmiStatus 2.1.866.20.10.10.60.20.1.3
The value of this object indicates the LMI state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), down(2), up(3)  

fmsFrLineCircuitCount 2.1.866.20.10.10.60.20.1.4
The value of this object indicates the total number of the DLCI on this physical line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsFrLineActiveCircuitCount 2.1.866.20.10.10.60.20.1.5
The value of this objects is the number of active DLCI on this physical line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmStatFrCircuitTable 2.1.866.20.10.10.60.21
This table contains the information about each circuit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatFrCircuitEntry

fmStatFrCircuitEntry 2.1.866.20.10.10.60.21.1
An entry of fmStatFrCircuitTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatFrCircuitEntry  

fmsFrCircuitLineId 2.1.866.20.10.10.60.21.1.1
The value of this object is the one physical line identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsFrCircuitDlci 2.1.866.20.10.10.60.21.1.2
The value of this object is the identifier of one circuit. It is the DLCI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

fmsFrCircuitStatus 2.1.866.20.10.10.60.21.1.3
The value of this object is the state of this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

fmsFrCircuitAge 2.1.866.20.10.10.60.21.1.4
The value of this object indicates the age of this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER old(1), new(2), indeterminate(3)  

fmsFrCircuitOutOctetsCounter 2.1.866.20.10.10.60.21.1.5
The value of this object is the number of octets sent on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrCircuitInOctetsCounter 2.1.866.20.10.10.60.21.1.6
The value of this object is the number of octets received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsFrCommIdentification 2.1.866.20.10.10.60.30
OBJECT IDENTIFIER    

fmsFrCommStorageTable 2.1.866.20.10.10.60.30.1
This table contains
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsFrCommStorageEntry

fmsFrCommStorageEntry 2.1.866.20.10.10.60.30.1.1
An entry of fmsFrCommStorageTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsFrCommStorageEntry  

fmsFrcStoragePhysIfId 2.1.866.20.10.10.60.30.1.1.1
Interface physique
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmsFrcStorageChannelId 2.1.866.20.10.10.60.30.1.1.2
Channel ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

fmsFrcStorageDlci 2.1.866.20.10.10.60.30.1.1.3
DLCI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

fmsFrcStorageSubDlci 2.1.866.20.10.10.60.30.1.1.4
Channel
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

fmsFrcStorageTypeOfDlci 2.1.866.20.10.10.60.30.1.1.5
Type de DLCI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), svc(2), pvc(255)  

fmsFrcStorageDirection 2.1.866.20.10.10.60.30.1.1.6
Direction
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fmsFrcStorageTypeOfTransport 2.1.866.20.10.10.60.30.1.1.7
Type de transport
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tunnel(19), annexG(32), frsna(34), frt(36), switch(99), unknown(255)  

fmsFrcStoragePvcStatus 2.1.866.20.10.10.60.30.1.1.8
PVC Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), unknown(255)  

fmsFrcStorageDestAddr 2.1.866.20.10.10.60.30.1.1.9
Destinataire
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fmsFrcStorageSrcAddr 2.1.866.20.10.10.60.30.1.1.10
Adresse source
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fmsFrcStorageCos 2.1.866.20.10.10.60.30.1.1.11
COS
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vbr(1), vbr-rt(2), ubr(3), unknown(255)  

fmsFrcStorageCir 2.1.866.20.10.10.60.30.1.1.12
CIR
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2048000  

fmsFrcStorageMinCir 2.1.866.20.10.10.60.30.1.1.13
CIR Min
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2048000  

fmsFrcStorageBc 2.1.866.20.10.10.60.30.1.1.14
BC
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2048000  

fmsFrcStorageBe 2.1.866.20.10.10.60.30.1.1.15
BE
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2048000  

fmsFrCommFilter 2.1.866.20.10.10.60.30.2
OBJECT IDENTIFIER    

fmsFrcFilterPhysIfId 2.1.866.20.10.10.60.30.2.1
Interface physique
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..10)  

fmsFrcFilterChannelId 2.1.866.20.10.10.60.30.2.2
Channel ID
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..10)  

fmsFrcFilterDlci 2.1.866.20.10.10.60.30.2.3
DLCI
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..10)  

fmsFrcFilterAction 2.1.866.20.10.10.60.30.2.4
Action
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER setFilter(1), activateFilter(2)  

fmStatPointToPointProtocol 2.1.866.20.10.10.71
OBJECT IDENTIFIER    

fmStatPppPhysLineTable 2.1.866.20.10.10.71.1
This table contains the general information about PPP lines.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatPppPhysLineEntry

fmStatPppPhysLineEntry 2.1.866.20.10.10.71.1.1
An entry of fmStatPppPhysLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatPppPhysLineEntry  

fmsPppPhysLineId 2.1.866.20.10.10.71.1.1.1
The value of this object is the one physical port identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsPppPhysLocalMru 2.1.866.20.10.10.71.1.1.2
The value of this object is the current value of the MRU (Maximum Receive Unit) for the local PPP entity. This value is the MRU that the remote entity is using when sending packets to the local PPP entity. The value of this object is meaningful only when the link has reached the open state (ifOperStatus is up).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..1600  

fmsPppPhysRemoteMru 2.1.866.20.10.10.71.1.1.3
The value of this object is the current value of the MRU (Maximum Receive Unit) for the remote PPP entity. This value is the MRU that the local entity is using when sending packets to the remote PPP entity. The value of this object is meaningful only when the link has reached the open state (ifOperStatus is up).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..1600  

fmsPppPhysMagicNumber 2.1.866.20.10.10.71.1.1.4
The value of this object indicates the magic number state. If 'used' then the local node will attempt to perform Magic Number negotiation with the remote node. If 'notUsed' then this negotiation is not performed. In any event, the local node will comply with any magic number negotiations attempted by the remote node, per the PPP specification. Changing this object will have an effect when the link is next restarted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER used(1), notUsed(2)  

fmStatPppProtocolStatusTable 2.1.866.20.10.10.71.2
This table contains the information about the protocol layers (LCP and NCP level) for each PPP line.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatPppProtocolStatusEntry

fmStatPppProtocolStatusEntry 2.1.866.20.10.10.71.2.1
An entry of fmStatPppProtocolStatusTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatPppProtocolStatusEntry  

fmsPppProtoLineId 2.1.866.20.10.10.71.2.1.1
The value of this object is the one PPP line identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsPppProtoLcpStatus 2.1.866.20.10.10.71.2.1.2
The value of this object is the current state of the LCP layer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER stop(1), wait(2), opening(3), up(4), down(5), closed(6), freeze(7)  

fmsPppProtoLcpDiag 2.1.866.20.10.10.71.2.1.3
The value of this object is the LCP layer diagnostic report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), timeOut(2), underlyingLayerDown(3), protocol(4), rejected(5), authenticationFailure(6)  

fmsPppProtoIpNcpStatus 2.1.866.20.10.10.71.2.1.4
The value of this object is the current state of the IP NCP layer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER stop(1), wait(2), opening(3), up(4), down(5), closed(6), freeze(7)  

fmsPppProtoIpNcpDiag 2.1.866.20.10.10.71.2.1.5
The value of this object is the IP NCP layer diagnostic report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), timeOut(2), underlyingLayerDown(3), protocol(4), rejected(5)  

fmsPppProtoBrdgNcpStatus 2.1.866.20.10.10.71.2.1.6
The value of this object is the current state of the Bridge NCP layer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER stop(1), wait(2), opening(3), up(4), down(5), closed(6), freeze(7)  

fmsPppProtoBrdgNcpDiag 2.1.866.20.10.10.71.2.1.7
The value of this object is the Bridge NCP layer diagnostic report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), timeOut(2), underlyingLayerDown(3), protocol(4), rejected(5)  

fmsPppProtoIpxNcpStatus 2.1.866.20.10.10.71.2.1.8
The value of this object is the current state of the IPX NCP layer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER stop(1), wait(2), opening(3), up(4), down(5), closed(6), freeze(7)  

fmsPppProtoIpxNcpDiag 2.1.866.20.10.10.71.2.1.9
The value of this object is the IPX NCP layer diagnostic report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), timeOut(2), underlyingLayerDown(3), protocol(4), rejected(5)  

fmsPppProtoClnpNcpStatus 2.1.866.20.10.10.71.2.1.10
The value of this object is the current state of the CLNP NCP layer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER stop(1), wait(2), opening(3), up(4), down(5), closed(6), freeze(7)  

fmsPppProtoClnpNcpDiag 2.1.866.20.10.10.71.2.1.11
The value of this object is the CLNP NCP layer diagnostic report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), timeOut(2), underlyingLayerDown(3), protocol(4), rejected(5)  

fmStatPppAuthenticationTable 2.1.866.20.10.10.71.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatPppAuthenticationEntry

fmStatPppAuthenticationEntry 2.1.866.20.10.10.71.10.1
An entry of fmStatPppAuthenticationTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatPppAuthenticationEntry  

fmsPppAuthLineId 2.1.866.20.10.10.71.10.1.1
Numero de la ligne PPP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsPppAuthMasterAuthentication 2.1.866.20.10.10.71.10.1.10
Authentifieur : Protocole d'authentification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), pap(2), chap(3)  

fmsPppAuthMasterSuccessCounter 2.1.866.20.10.10.71.10.1.11
Authentifieur : Nb d'authentifications reussies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsPppAuthMasterFailureCounter 2.1.866.20.10.10.71.10.1.12
Authentifieur : Nb d'authentifications echouees.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsPppAuthSlaveAuthentication 2.1.866.20.10.10.71.10.1.20
Authentifie : Protocole d'authentification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), pap(2), chap(3)  

fmsPppAuthSlaveSuccessCounter 2.1.866.20.10.10.71.10.1.21
Authentifie : Nb d'authentifications reussies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsPppAuthSlaveFailureCounter 2.1.866.20.10.10.71.10.1.22
Authentifie : Nb d'authentifications echouees.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmStatPppIpAddrAssignmentTable 2.1.866.20.10.10.71.11
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatPppIpAddrAssignmentEntry

fmStatPppIpAddrAssignmentEntry 2.1.866.20.10.10.71.11.1
An entry of fmStatPppIpAddrAssignmentTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatPppIpAddrAssignmentEntry  

fmsPppIpAddrLineId 2.1.866.20.10.10.71.11.1.1
Numero de la ligne PPP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsPppIpAddrReceived 2.1.866.20.10.10.71.11.1.10
Adresse IP recue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmsPppIpAddrSent 2.1.866.20.10.10.71.11.1.11
Adresse IP attribuee.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmStatE1 2.1.866.20.10.10.80
OBJECT IDENTIFIER    

fmStatE1Ds1ChannelNumber 2.1.866.20.10.10.80.1
OBJECT IDENTIFIER    

fmsE1Ds1ChIfNumber 2.1.866.20.10.10.80.1.1
Nombre de canaux E1 ou DS1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..60  

fmStatE1Ds1ChannelTable 2.1.866.20.10.10.80.2
This table contains
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatE1Ds1ChannelEntry

fmStatE1Ds1ChannelEntry 2.1.866.20.10.10.80.2.1
An entry of fmStatE1Ds1ChannelTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatE1Ds1ChannelEntry  

fmsE1Ds1ChIfPhysId 2.1.866.20.10.10.80.2.1.1
Interface physique E1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsE1Ds1ChIfChannelId 2.1.866.20.10.10.80.2.1.2
Interface canal E1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 42..131  

fmsE1Ds1ChIfType 2.1.866.20.10.10.80.2.1.3
Type de l'interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), rfc877-x25(5), ppp(23), frame-relay(32), hdlc-t(100)  

fmsE1Ds1ChIfDescr 2.1.866.20.10.10.80.2.1.4
Description
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fmsE1Ds1ChIfMtu 2.1.866.20.10.10.80.2.1.5
Taille maximum d'une trame
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmsE1Ds1ChIfSpeed 2.1.866.20.10.10.80.2.1.6
Debit de l'interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmsE1Ds1ChIfPhysAddress 2.1.866.20.10.10.80.2.1.7
Adresse physique
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

fmsE1Ds1ChIfAdminStatus 2.1.866.20.10.10.80.2.1.8
Etat desire de l'interface
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

fmsE1Ds1ChIfOperStatus 2.1.866.20.10.10.80.2.1.9
Etat operationnel de l'interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

fmsE1Ds1ChIfLastChange 2.1.866.20.10.10.80.2.1.10
Valeur de sysUpTime au moment ou l'interface est passe dans l'etat operationnel courant
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fmsE1Ds1ChIfInOctets 2.1.866.20.10.10.80.2.1.11
Nombre d'octets recus
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfInUcastPkts 2.1.866.20.10.10.80.2.1.12
Nombre de paquets Unicast recus
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfInNUcastPkts 2.1.866.20.10.10.80.2.1.13
Nombre de paquets non Unicast recus
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfInDiscards 2.1.866.20.10.10.80.2.1.14
Nombre de paquets recus detruits
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfInErrors 2.1.866.20.10.10.80.2.1.15
Nombre de paquets recus en erreur
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfInUnknownProtos 2.1.866.20.10.10.80.2.1.16
Nombre de paquets recus avec protocole inconnu
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfOutOctets 2.1.866.20.10.10.80.2.1.17
Nombre d'octets emis
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfOutUcastPkts 2.1.866.20.10.10.80.2.1.18
Nombre de paquets Unicast emis
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfOutNUcastPkts 2.1.866.20.10.10.80.2.1.19
Nombre de paquets non Unicast emis
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfOutDiscards 2.1.866.20.10.10.80.2.1.20
Nombre de paquets emis detruits
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfOutErrors 2.1.866.20.10.10.80.2.1.21
Nombre de paquets emis en erreur
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsE1Ds1ChIfOutQLen 2.1.866.20.10.10.80.2.1.22
Longueur de la file des paquets emis
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmsE1Ds1ChIfSpecific 2.1.866.20.10.10.80.2.1.23
OID de la MIB de reference
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmStatS2 2.1.866.20.10.10.90
OBJECT IDENTIFIER    

fmStatS2BChannelTable 2.1.866.20.10.10.90.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatS2BChannelEntry

fmStatS2BChannelEntry 2.1.866.20.10.10.90.1.1
An entry of fmStatS2BChannelTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatS2BChannelEntry  

fmsS2BChPhysIfId 2.1.866.20.10.10.90.1.1.1
Interface physique associee au canal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmsS2BChChannelId 2.1.866.20.10.10.90.1.1.2
Numero de canal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..30  

fmsS2BChProto 2.1.866.20.10.10.90.1.1.3
Protocole associe au canal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), rfc877-x25(5), ppp(23), frame-relay(32)  

fmsS2BChIfSpeed 2.1.866.20.10.10.90.1.1.4
Debit du canal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmsS2BChAdminStatus 2.1.866.20.10.10.90.1.1.5
Etat desire du canal
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

fmsS2BChOperStatus 2.1.866.20.10.10.90.1.1.6
Etat operationnel du canal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

fmsS2BChIfLastChange 2.1.866.20.10.10.90.1.1.7
Valeur de sysUpTime au moment ou le canal est passe dans l'etat operationnel courant
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fmsS2BChIfInOctets 2.1.866.20.10.10.90.1.1.8
Nombre d'octets recus
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsS2BChIfOutOctets 2.1.866.20.10.10.90.1.1.9
Nombre d'octets emis
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsS2BChIfCalledAddress 2.1.866.20.10.10.90.1.1.10
Adresse appelee
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

fmsS2BChIfCallingAddress 2.1.866.20.10.10.90.1.1.11
Adresse appelante
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

fmStatS0 2.1.866.20.10.10.91
OBJECT IDENTIFIER    

fmStatS0BChannelTable 2.1.866.20.10.10.91.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmStatS0BChannelEntry

fmStatS0BChannelEntry 2.1.866.20.10.10.91.1.1
An entry of fmStatS0BChannelTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmStatS0BChannelEntry  

fmsS0BChPhysIfId 2.1.866.20.10.10.91.1.1.1
The value of this object is the number of the physical port the basic rate interface B channel is related to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..6  

fmsS0BChChannelId 2.1.866.20.10.10.91.1.1.2
The value of this object is the identification number of the basic rate interface B channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..9  

fmsS0BChProto 2.1.866.20.10.10.91.1.1.3
The value of this object is the protocol related to the basic rate interface B channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), rfc877-x25(5), ppp(23), frame-relay(32)  

fmsS0BChIfSpeed 2.1.866.20.10.10.91.1.1.4
The value of this object is the speed of the basic rate interface B channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmsS0BChAdminStatus 2.1.866.20.10.10.91.1.1.5
The value of this object is the operational state wanted for the basic rate interface B channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

fmsS0BChOperStatus 2.1.866.20.10.10.91.1.1.6
The value of this object is the current operational state of the basic rate interface B channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

fmsS0BChIfLastChange 2.1.866.20.10.10.91.1.1.7
The value of this object is the value of the sysUpTime at the time when the basic rate interface B channel took its current operational state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fmsS0BChIfInOctets 2.1.866.20.10.10.91.1.1.8
The value of this object is the number of bytes received on the basic rate interface B channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsS0BChIfOutOctets 2.1.866.20.10.10.91.1.1.9
The value of this object is the number of bytes sent on the basic rate interface B channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsS0BChIfCalledAddress 2.1.866.20.10.10.91.1.1.10
The value of this object is the called address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

fmsS0BChIfCallingAddress 2.1.866.20.10.10.91.1.1.11
The value of this object is the caller address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

fmOsi 2.1.866.20.10.15
OBJECT IDENTIFIER    

fmOsiCLNP 2.1.866.20.10.15.1
OBJECT IDENTIFIER    

fmOsiCLNPSystem 2.1.866.20.10.15.1.1
OBJECT IDENTIFIER    

fmOsiForwarding 2.1.866.20.10.15.1.1.20
Forwarding
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fmOsiCLNPSysOutPDUs 2.1.866.20.10.15.1.1.30
clnpSysOutPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiCLNPSysInPDUs 2.1.866.20.10.15.1.1.35
clnpSysInPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiCLNPSysErrMemFails 2.1.866.20.10.15.1.1.40
clnpSysErrMemFails
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiCLNPCircuitTable 2.1.866.20.10.15.1.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOsiCLNPCircuitEntry

fmOsiCLNPCircuitEntry 2.1.866.20.10.15.1.5.1
An entry of fmOsiCLNPCircuitTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOsiCLNPCircuitEntry  

fmOsiCLNPCircIndex 2.1.866.20.10.15.1.5.1.1
clnpCircIndex
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..60  

fmOsiCLNPCircOutPDUs 2.1.866.20.10.15.1.5.1.35
clnpCircOutPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiCLNPCircInPDUs 2.1.866.20.10.15.1.5.1.40
clnpCircInPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiESIS 2.1.866.20.10.15.5
OBJECT IDENTIFIER    

fmOsiESISSystem 2.1.866.20.10.15.5.1
OBJECT IDENTIFIER    

fmOsiESISSysOutPDUs 2.1.866.20.10.15.5.1.30
esisSysOutPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiESISSysInPDUs 2.1.866.20.10.15.5.1.35
esisSysInPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiESISCircuitTable 2.1.866.20.10.15.5.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOsiESISCircuitEntry

fmOsiESISCircuitEntry 2.1.866.20.10.15.5.5.1
An entry of fmOsiESISCircuitTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOsiESISCircuitEntry  

fmOsiESISCircIndex 2.1.866.20.10.15.5.5.1.1
esisCircIndex
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..60  

fmOsiESISCircOutPDUs 2.1.866.20.10.15.5.5.1.35
esisCircOutPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiESISCircInPDUs 2.1.866.20.10.15.5.5.1.40
esisCircInPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISIS 2.1.866.20.10.15.10
OBJECT IDENTIFIER    

fmOsiISISSystem 2.1.866.20.10.15.10.1
OBJECT IDENTIFIER    

fmOsiISISSysOutPdu 2.1.866.20.10.15.10.1.30
isisSysOutPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISSysInPdu 2.1.866.20.10.15.10.1.33
isisSysInPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISSysL1State 2.1.866.20.10.15.10.1.35
isisSysL1State
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2), waiting(3)  

fmOsiISISSysCorrLSP 2.1.866.20.10.15.10.1.37
isisSysCorrLSPs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISSysL1DbaseOloads 2.1.866.20.10.15.10.1.40
isisSysLSPL1DbaseOloads
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISSysttmpToExMaxSaqNums 2.1.866.20.10.15.10.1.42
isisSysAttmptToExMaxSeqNums
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISSysSeqNumSkips 2.1.866.20.10.15.10.1.44
isisSysSeqNumSkips
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISSysOwnLSPPurges 2.1.866.20.10.15.10.1.46
isisSysOwnLSPPurges
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISSysISFieldLenMismatches 2.1.866.20.10.15.10.1.48
isisSysIDFieldLenMismatches
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISSysMaxAreaAddrMismatches 2.1.866.20.10.15.10.1.50
isisSysMaxAreaAddrMismatches
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISSysL2State 2.1.866.20.10.15.10.1.52
isisSysL2State
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2), waiting(3)  

fmOsiISISSysLSPL2DbaseOloads 2.1.866.20.10.15.10.1.54
isisSysLSPL2DbaseOloads
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISSysAuthFails 2.1.866.20.10.15.10.1.56
isisSysAuthFails
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISLogAdjcencyStateChanges 2.1.866.20.10.15.10.1.58
isisLogAdjacencyStateChanges
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

fmOsiISISCircuitTable 2.1.866.20.10.15.10.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOsiISISCircuitEntry

fmOsiISISCircuitEntry 2.1.866.20.10.15.10.5.1
An entry of fmOsiISISCircuitTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOsiISISCircuitEntry  

fmOsiISISCircIndex 2.1.866.20.10.15.10.5.1.1
isisCircIndex
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..60  

fmOsiISISCircOutPdu 2.1.866.20.10.15.10.5.1.30
isisCircOutPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircInPdu 2.1.866.20.10.15.10.5.1.35
isisCircInPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircAdjChanges 2.1.866.20.10.15.10.5.1.40
isisCircAdjChanges
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircInitFails 2.1.866.20.10.15.10.5.1.42
isisCircInitFails
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircRejAdjs 2.1.866.20.10.15.10.5.1.44
isisCircRejAdjs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircOutCtrlPdu 2.1.866.20.10.15.10.5.1.46
isisCircOutCtrlPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircInCrtlPdu 2.1.866.20.10.15.10.5.1.48
isisCircInCtrlPDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircIDFieldLenMismatches 2.1.866.20.10.15.10.5.1.50
isisCircIDFieldLenMismatches
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircMaxAreaAddrMismatches 2.1.866.20.10.15.10.5.1.52
isisCircMaxAreaAddrMismatches
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircL1DesIS 2.1.866.20.10.15.10.5.1.54
isisCircL1DesIS
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..12)  

fmOsiISISCircLANL1DesISChanges 2.1.866.20.10.15.10.5.1.56
isisCircLANL1DesISChanges
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircL2DesIS 2.1.866.20.10.15.10.5.1.58
isisCircL2DesIS
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..12)  

fmOsiISISCircLANL2DesISChanges 2.1.866.20.10.15.10.5.1.60
isisCircLANL2DesISChanges
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISCircAuthFails 2.1.866.20.10.15.10.5.1.62
isisCircAuthFails
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOsiISISAreaTable 2.1.866.20.10.15.10.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOsiISISAreaEntry

fmOsiISISAreaEntry 2.1.866.20.10.15.10.10.1
An entry of fmOsiISISAreaTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOsiISISAreaEntry  

fmOsiISISAreaAddress 2.1.866.20.10.15.10.10.1.1
Area Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..46)  

fmOsiISISISAdjacencyTable 2.1.866.20.10.15.10.15
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOsiISISISAdjacencyEntry

fmOsiISISISAdjacencyEntry 2.1.866.20.10.15.10.15.1
An entry of fmOsiISISISAdjacencyTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOsiISISISAdjacencyEntry  

fmOsiISISISAdjCircIndex 2.1.866.20.10.15.10.15.1.1
Circuit Index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..60  

fmOsiISISISAdjIndex 2.1.866.20.10.15.10.15.1.5
Adjacency Index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

fmOsiISISISAdjSysID 2.1.866.20.10.15.10.15.1.10
System ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

fmOsiISISISAdjState 2.1.866.20.10.15.10.15.1.12
State
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initializing(1), up(2), failed(3), down(4)  

fmOsiISISISAdjSNPAAddress 2.1.866.20.10.15.10.15.1.14
SNPA Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..46)  

fmOsiISISISAdjType 2.1.866.20.10.15.10.15.1.20
Type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

fmOsiISISISAdjUsage 2.1.866.20.10.15.10.15.1.22
Usage
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER undefined(1), level1(2), level2(3), level1and2(4)  

fmOsiISISISAdjHoldTimer 2.1.866.20.10.15.10.15.1.26
Holding Timer
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmOsiISISISAdjPriority 2.1.866.20.10.15.10.15.1.30
Priority
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

fmOsiISISISAdjacencyAreaAddressTable 2.1.866.20.10.15.10.17
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOsiISISISAdjacencyAreaAddressEntry

fmOsiISISISAdjacencyAreaAddressEntry 2.1.866.20.10.15.10.17.1
An entry of fmOsiISISISAdjacencyAreaAddressTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOsiISISISAdjacencyAreaAddressEntry  

fmOsiISISISAdjAreaAddrCircIndex 2.1.866.20.10.15.10.17.1.1
Circuit Index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..60  

fmOsiISISISAdjAreaAddrAdjIndex 2.1.866.20.10.15.10.17.1.3
Adjacency Index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

fmOsiISISISAdjAreaAddress 2.1.866.20.10.15.10.17.1.5
Area Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..46)  

fmOsiISISESAdjacencyTable 2.1.866.20.10.15.10.20
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOsiISISESAdjacencyEntry

fmOsiISISESAdjacencyEntry 2.1.866.20.10.15.10.20.1
An entry of fmOsiISISESAdjacencyTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOsiISISESAdjacencyEntry  

fmOsiISISESAdjCircIndex 2.1.866.20.10.15.10.20.1.1
Circuit Index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..60  

fmOsiISISESAdjAdjIndex 2.1.866.20.10.15.10.20.1.3
Adjacency Index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

fmOsiISISESAdjESID 2.1.866.20.10.15.10.20.1.5
System ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

fmOsiISISESAdjState 2.1.866.20.10.15.10.20.1.10
State
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initializing(1), up(2), failed(3), down(4)  

fmOsiISISESAdjNeighSNPAAdress 2.1.866.20.10.15.10.20.1.15
SNPA Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..46)  

fmOsiISISESAdjType 2.1.866.20.10.15.10.20.1.20
Type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

fmOsiISISReachableAddressTable 2.1.866.20.10.15.10.25
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOsiISISReachableAddressEntry

fmOsiISISReachableAddressEntry 2.1.866.20.10.15.10.25.1
An entry of fmOsiISISReachableAddressTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOsiISISReachableAddressEntry  

fmOsiISISRASystemType 2.1.866.20.10.15.10.25.1.1
System Type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER es(1), l1IS(2), l2IS(3), prefix(4)  

fmOsiISISRAAddress 2.1.866.20.10.15.10.25.1.5
Reachable Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..46)  

fmOsiISISRAMetric 2.1.866.20.10.15.10.25.1.10
Metric
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER default(1), delay(2), expense(3), error(4)  

fmOsiISISRAPathIdentifier 2.1.866.20.10.15.10.25.1.15
Path Idendifier
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..32  

fmOsiISISRAType 2.1.866.20.10.15.10.25.1.20
Type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

fmOsiISISRACircuitId 2.1.866.20.10.15.10.25.1.25
Circuit Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..60  

fmOsiISISRAAdjacencyId 2.1.866.20.10.15.10.25.1.35
Adjacency Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fmOsiISISRAPathCost 2.1.866.20.10.15.10.25.1.40
Path Cost
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

fmOsiISISRASNPAAddress 2.1.866.20.10.15.10.25.1.45
SNPA Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..46)  

fmPing 2.1.866.20.10.16
OBJECT IDENTIFIER    

fmPingTable 2.1.866.20.10.16.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmPingEntry

fmPingEntry 2.1.866.20.10.16.1.1
An entry of fmPingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmPingEntry  

fmPingIdentifier 2.1.866.20.10.16.1.1.1
Identifier
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2147483647  

fmPingProtocol 2.1.866.20.10.16.1.1.4
Protocol
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ip(1), clnp(8), novell(14)  

fmPingAddress 2.1.866.20.10.16.1.1.6
Address
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..46)  

fmPingCountRequest 2.1.866.20.10.16.1.1.10
CountRequest
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2147483647  

fmPingPacketSize 2.1.866.20.10.16.1.1.12
PacketSize
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 64..1500  

fmPingDelay 2.1.866.20.10.16.1.1.16
Delay
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600000  

fmPingTimeout 2.1.866.20.10.16.1.1.18
Timeout
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600000  

fmPingPermanent 2.1.866.20.10.16.1.1.20
Permanent Flag
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fmPingSentPackets 2.1.866.20.10.16.1.1.30
Sent Packets
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmPingReceivedPackets 2.1.866.20.10.16.1.1.32
Received Packets
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmPingMinRoundTrip 2.1.866.20.10.16.1.1.40
Min Round Trip
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmPingAvgRoundTrip 2.1.866.20.10.16.1.1.41
Avg Round Trip
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmPingMaxRoundTrip 2.1.866.20.10.16.1.1.42
Max Round Trip
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmPingCompletedFlag 2.1.866.20.10.16.1.1.48
Ping completed flag
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fmPingOwner 2.1.866.20.10.16.1.1.50
Owner description
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..75)  

fmPingAdminState 2.1.866.20.10.16.1.1.52
AdminState
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6), stop(7)  

fmRip2 2.1.866.20.10.17
OBJECT IDENTIFIER    

fmRip2GlobalGroup 2.1.866.20.10.17.1
OBJECT IDENTIFIER    

fmRip2GlobalRouteChanges 2.1.866.20.10.17.1.1
RIP2 Global Route Changes. The number of changes made to the IP Route Database by RIP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmRip2GlobalQueries 2.1.866.20.10.17.1.2
RIP2 Global Queries. The number of responses sent to RIP queries from other systems.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmRip2IfStatTable 2.1.866.20.10.17.2
A list of subnets which require separate status monitoring in RIP
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmRip2IfStatEntry

fmRip2IfStatEntry 2.1.866.20.10.17.2.1
An entry of fmRip2IfStatTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmRip2IfStatEntry  

fmRip2IfStatAddress 2.1.866.20.10.17.2.1.1
RIP2 Interface Stat Ip Address. The IP Address of this system on the indicated subnet
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmRip2IfStatRcvBadPackets 2.1.866.20.10.17.2.1.2
RIP2 Interface Stat Received Bad Packets. The number of RIP response packets received bythe RIP process which were subsequently discarded for any reason (e.g. a version 0 packet, or an unknown command type).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmRip2IfStatRcvBadRoutes 2.1.866.20.10.17.2.1.3
RIP2 Interface Stat Received Bad Routes. The number of routes, in valid RIP packets,which were ignored for any reason (e.g. unknown address family, or invalid metric).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmRip2IfStatSentUpdates 2.1.866.20.10.17.2.1.4
RIP2 Interface Stat Sent Updates. The number of triggered RIP updates actually sent on this interface. This explicitly does NOT include full updates sent containing new information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmRip2IfStatStatus 2.1.866.20.10.17.2.1.5
RIP2 Interface Stat Status. Writing invalid has the effect of deleting this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fmRip2IfConfTable 2.1.866.20.10.17.3
A list of subnets which require separate configuration in RIP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmRip2IfConfEntry

fmRip2IfConfEntry 2.1.866.20.10.17.3.1
An entry of fmRip2IfConfTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmRip2IfConfEntry  

fmRip2IfConfAddress 2.1.866.20.10.17.3.1.1
RIP2 Interface Conf Ip Address. The IP Address of this system on the indicated subnet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmRip2IfConfDomain 2.1.866.20.10.17.3.1.2
RIP2 Interface Conf Domain. Value inserted into the Routing Domain field of all RIP packets sent on this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..2)  

fmRip2IfConfAuthType 2.1.866.20.10.17.3.1.3
RIP2 Interface Conf Authentiction Type. The type of Authentication used on this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAuthentication(1), simplePassword(2)  

fmRip2IfConfAuthKey 2.1.866.20.10.17.3.1.4
RIP2 Interface Conf Authentication Key. The value to be used as the Authentication Key whenever the corresponding instance of rip2IfConfAuthType has the value simplePassword. A modification of the corresponding instance of rip2IfConfAuthType does not modify the rip2IfConfAuthKey value. If a string shorter than 16 octets is supplied, it will be left-justified and padded to 16 octets, on the right, with nulls (0x00). Reading this object always results in an OCTET STRING of length zero; authentication may not be bypassed by reading the MIB object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

fmRip2IfConfSend 2.1.866.20.10.17.3.1.5
RIP2 Interface Conf Send. What the router sends on this interface. ripVersion1 implies sending RIP updates compliant with RFC 1058. rip1Compatible implies broadcasting RIP-2 updates using RFC 1058 route subsumption rules. ripVersion2 implies multicasting RIP-2 updates.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER doNotSend(1), ripVersion1(2), rip1Compatible(3), ripVersion2(4)  

fmRip2IfConfReceive 2.1.866.20.10.17.3.1.6
RIP2 Interface Conf Receive. This indicates which version of RIP updates are to be accepted. Note that rip2 and rip1OrRip2 implies reception of multicast packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rip1(1), rip2(2), rip1OrRip2(3)  

fmRip2IfConfDefaultMetric 2.1.866.20.10.17.3.1.7
RIP2 Interface Conf Default Metric. This variable indicates what metric is to be used as a default route in RIP updates originated on this interface. A value of zero indicates that no default route should be originated; in this case, a default route via another router may be propagated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

fmRip2IfConfStatus 2.1.866.20.10.17.3.1.8
RIP2 Interface Conf Status. Writing invalid has the effect of deleting this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fmRip2PeerTable 2.1.866.20.10.17.4
A list of RIP Peers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmRip2PeerEntry

fmRip2PeerEntry 2.1.866.20.10.17.4.1
An entry of fmRip2PeerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmRip2PeerEntry  

fmRip2PeerAddress 2.1.866.20.10.17.4.1.1
RIP2 Peer Ip Address. The IP Address of the Peer System.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmRip2PeerDomain 2.1.866.20.10.17.4.1.2
RIP2 Peer Domain. The value in the Routing Domain field in RIP packets received from the peer
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..2)  

fmRip2PeerLastUpdate 2.1.866.20.10.17.4.1.3
RIP2 Peer Last Update. The value of sysUpTime when the most recent RIP update was received from this system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fmRip2PeerVersion 2.1.866.20.10.17.4.1.4
RIP2 Peer Version. The RIP version number in the header of the last RIP packet received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmRip2PeerRcvBadPackets 2.1.866.20.10.17.4.1.5
RIP2 Peer Received Bad Packets. The number of RIP response packets from this peer discarded as invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmRip2PeerRcvBadRoutes 2.1.866.20.10.17.4.1.6
RIP2 Peer Received Bad Routes. The number of routes from this peer that were ignored because the entry format was invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOspf 2.1.866.20.10.18
OBJECT IDENTIFIER    

fmOspfStandard 2.1.866.20.10.18.1
OBJECT IDENTIFIER    

fmOspfStandardGeneralGroup 2.1.866.20.10.18.1.1
OBJECT IDENTIFIER    

fmOspfStandardRouterId 2.1.866.20.10.18.1.1.1
OSPF Router Id. A 32-bit integer uniquely identifying the router in the Autonomous System. By convention, to ensure uniqueness, this should default to the value of one of the router's IP interface addresses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardAdminStat 2.1.866.20.10.18.1.1.2
OSPF Administrative Status. The administrative status of OSPF in the router. The value 'enabled' denotes that the OSPF Process is active on at least one interface; 'disabled' disables it on all interfaces.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

fmOspfStandardVersionNumber 2.1.866.20.10.18.1.1.3
OSPF Version Number. The current version number of the OSPF protocol is 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER version1(1), version2(2)  

fmOspfStandardAreaBdrRtrStatus 2.1.866.20.10.18.1.1.4
OSPF Area Border Router Status. A flag to note whether this router is an area border router.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fmOspfStandardASBdrRtrStatus 2.1.866.20.10.18.1.1.5
OSPF AS Border Router Status A flag to note whether this router is an Autonomous System border router.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fmOspfStandardExternLSACount 2.1.866.20.10.18.1.1.6
OSPF Extern LSA Count. The number of external (LS type 5) link-state advertisements in the link-state database.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmOspfStandardExternLSACksumSum 2.1.866.20.10.18.1.1.7
OSPF Extern LSA Checksum. The 32-bit unsigned sum of the LS checksums of the external link-state advertisements contained in the link-state database. This sum can be used to determine if there has been a change in a router's link state database, and to compare the link-state database of two routers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmOspfStandardTOSSupport 2.1.866.20.10.18.1.1.8
OSPF TOS Support. The router's support for type-of-service routing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fmOspfStandardOriginateNewLSAs 2.1.866.20.10.18.1.1.9
OSPF Originate New LSAs. The number of new link-state advertisements that have been originated. This number is incremented each time the router originates a new LSA.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOspfStandardRxNewLSAs 2.1.866.20.10.18.1.1.10
OSPF Receive New LSAs. The number of link-state advertisements received determined to be new instantiations. This number does not include newer instantiations of self-originated link-state advertisements.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOspfStandardAreaTable 2.1.866.20.10.18.1.2
Information describing the configured parameters and cumulative statistics of the router's attached areas.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOspfStandardAreaEntry

fmOspfStandardAreaEntry 2.1.866.20.10.18.1.2.1
An entry of fmOspfStandardAreaTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOspfStandardAreaEntry  

fmOspfStandardAreaId 2.1.866.20.10.18.1.2.1.1
OSPF Area Id. A 32-bit integer uniquely identifying an area. Area ID 0.0.0.0 is used for the OSPF backbone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardAuthType 2.1.866.20.10.18.1.2.1.2
OSPF Area Authentication Type. The authentication type specified for an area. Additional authentication types may be assigned locally on a per Area basis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmOspfStandardImportASExtern 2.1.866.20.10.18.1.2.1.3
OSPF Area Import AS Extern. The area's support for importing AS external link-state advertisements.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fmOspfStandardSpfRuns 2.1.866.20.10.18.1.2.1.4
OSPF Area SPF Runs. The number of times that the intra-area route table has been calculated using this area's link-state database. This is typically done using Dijkstra's algorithm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOspfStandardAreaBdrRtrCount 2.1.866.20.10.18.1.2.1.5
OSPF Area Border Router Count. The total number of area border routers reachable within this area. This is initially zero, and is calculated in each SPF Pass.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmOspfStandardASBdrRtrCount 2.1.866.20.10.18.1.2.1.6
OSPF Area AS Border Router Count. The total number of Autonomous System border routers reachable within this area. This is initially zero, and is calculated in each SPF Pass.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmOspfStandardAreaLSACount 2.1.866.20.10.18.1.2.1.7
OSPF Area LSA Count. The total number of link-state advertisements in this area's link-state database, excluding AS External LSA's.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmOspfStandardAreaLSACksumSum 2.1.866.20.10.18.1.2.1.8
OSPF Area LSA Checksum Sum. The 32-bit unsigned sum of the link-state advertisements' LS checksums contained in this area's link-state database. This sum excludes external (LS type 5) link-state advertisements. The sum can be used to determine if there has been a change in a router's link state database, and to compare the link-state database of two routers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmOspfStandardStubAreaTable 2.1.866.20.10.18.1.3
The set of metrics that will be advertised by a default Area Border Router into a stub area
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOspfStandardStubAreaEntry

fmOspfStandardStubAreaEntry 2.1.866.20.10.18.1.3.1
An entry of fmOspfStandardStubAreaTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOspfStandardStubAreaEntry  

fmOspfStandardStubAreaID 2.1.866.20.10.18.1.3.1.1
OSPF Stub Area Id. The 32 bit identifier for the Stub Area. On creation, this can be derived from the instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardStubTOS 2.1.866.20.10.18.1.3.1.2
OSPF Stub Area TOS. The Type of Service associated with the metric. On creation, this can be derived from the instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

fmOspfStandardStubMetric 2.1.866.20.10.18.1.3.1.3
OSPF Stub Area Metric. The metric value applied at the indicated type of service. By default, this equals the least metric at the type of service among the interfaces to other areas.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16777215  

fmOspfStandardStubStatus 2.1.866.20.10.18.1.3.1.4
OSPF Stub Area Status. This variable displays the validity or invalidity of the entry. Setting it to 'invalid' has the effect of rendering it inoperative. The internal effect (row removal) is implementation dependent .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fmOspfStandardLsdbTable 2.1.866.20.10.18.1.4
The OSPF Process's Links State Database.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOspfStandardLsdbEntry

fmOspfStandardLsdbEntry 2.1.866.20.10.18.1.4.1
An entry of fmOspfStandardLsdbTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOspfStandardLsdbEntry  

fmOspfStandardLsdbAreaId 2.1.866.20.10.18.1.4.1.1
OSPF Link State Database Area Id The OSPF Process's Links State Database.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardLsdbType 2.1.866.20.10.18.1.4.1.2
OSPF Link State Database LS Type. The type of the link state advertisement. Each link state type has a separate advertisement format.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER routerLink(1), networkLink(2), summaryLink(3), asSummaryLink(4), asExternalLink(5)  

fmOspfStandardLsdbLSID 2.1.866.20.10.18.1.4.1.3
OSPF Link State Database LS Id. The Link State ID is an LS Type Specific field containing either a Router ID or an IP Address; it identifies the piece of the routing domain that is being described by the advertisement.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardLsdbRouterId 2.1.866.20.10.18.1.4.1.4
OSPF Link State Database Router Id. The 32 bit number that uniquely identifies the originating router in the Autonomous System.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardLsdbSequence 2.1.866.20.10.18.1.4.1.5
OSPF Link State Database Sequence. The sequence number field is a signed 32-bit integer. It is used to detect old and duplicate link state advertisements. The space of sequence numbers is linearly ordered. The larger the sequence number the more recent the advertisement.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmOspfStandardLsdbAge 2.1.866.20.10.18.1.4.1.6
OSPF Link State Database Age. This field is the age of the link state advertisement in seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmOspfStandardLsdbChecksum 2.1.866.20.10.18.1.4.1.7
OSPF Link State Database Checksum. This field is the checksum of the complete contents of the advertisement, excepting the age field. The age field is excepted so that an advertisement's age can be incremented without updating the checksum. The checksum used is the same that is used for ISO connectionless datagrams; it is commonly referred to as the Fletcher checksum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmOspfStandardLsdbAdvertisement 2.1.866.20.10.18.1.4.1.8
OSPF Link State Database Advertisement. The entire Link State Advertisement, including its header.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

fmOspfStandardAreaRangeTable 2.1.866.20.10.18.1.5
A range if IP addresses specified by an IP address/IP network mask pair. For example, class B address range of X.X.X.X with a network mask of 255.255.0.0 includes all IP addresses from X.X.0.0 to X.X.255.255.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOspfStandardAreaRangeEntry

fmOspfStandardAreaRangeEntry 2.1.866.20.10.18.1.5.1
An entry of fmOspfStandardAreaRangeTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOspfStandardAreaRangeEntry  

fmOspfStandardAreaRangeAreaID 2.1.866.20.10.18.1.5.1.1
OSPF Area Range Area Id. The Area the Address Range is to be found within.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardAreaRangeNet 2.1.866.20.10.18.1.5.1.2
OSPF Area Range Net. The IP Address of the Net or Subnet indicated by the range.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardAreaRangeMask 2.1.866.20.10.18.1.5.1.3
OSPF Area Range Mask. The Subnet Mask that pertains to the Net or Subnet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardAreaRangeStatus 2.1.866.20.10.18.1.5.1.4
OSPF Area Range Status. This variable displays the validity or invalidity of the entry. Setting it to 'invalid' has the effect of rendering it inoperative. The internal effect (row removal) is implementation dependent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fmOspfStandardHostTable 2.1.866.20.10.18.1.6
The list of Hosts, and their metrics, that the router will advertise as host routes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOspfStandardHostEntry

fmOspfStandardHostEntry 2.1.866.20.10.18.1.6.1
An entry of fmOspfStandardHostTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOspfStandardHostEntry  

fmOspfStandardHostIpAddress 2.1.866.20.10.18.1.6.1.1
OSPF Host Ip Address. The IP Address of the Host.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardHostTOS 2.1.866.20.10.18.1.6.1.2
OSPF Host TOS. The Type of Service of the route being configured.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

fmOspfStandardHostMetric 2.1.866.20.10.18.1.6.1.3
OSPF Host Metric. The Metric to be advertised.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fmOspfStandardHostStatus 2.1.866.20.10.18.1.6.1.4
OSPF Host Status. This variable displays the validity or invalidity of the entry. Setting it to 'invalid' has the effect of rendering it inoperative. The internal effect (row removal) is implementation dependent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fmOspfStandardIfTable 2.1.866.20.10.18.1.7
The OSPF Interface Table describes the interfaces from the viewpoint of OSPF.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOspfStandardIfEntry

fmOspfStandardIfEntry 2.1.866.20.10.18.1.7.1
An entry of fmOspfStandardIfTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOspfStandardIfEntry  

fmOspfStandardIfIpAddress 2.1.866.20.10.18.1.7.1.1
OSPF Interface Ip Address. The IP address of this OSPF interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardAddressLessIf 2.1.866.20.10.18.1.7.1.2
OSPF Interface Address Less If. For the purpose of easing the instancing of addressed and addressless interfaces; This variable takes the value 0 on interfaces with IP Addresses, and the corresponding value of ifIndex for interfaces having no IP Address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmOspfStandardIfAreaId 2.1.866.20.10.18.1.7.1.3
OSPF Interface Area Id. A 32-bit integer uniquely identifying the area to which the interface connects. Area ID 0.0.0.0 is used for the OSPF backbone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardIfType 2.1.866.20.10.18.1.7.1.4
OSPF Interface Type. The OSPF interface type. By way of a default, this field may be intuited from the corresponding value of ifType. Broadcast LANs, such as Ethernet and IEEE 802.5, take the value 'broadcast', X.25, Frame Relay, and similar technologies take the value 'nbma', and links that are definitively point to point take the value 'pointToPoint'
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER broadcast(1), nbma(2), pointToPoint(3)  

fmOspfStandardIfAdminStat 2.1.866.20.10.18.1.7.1.5
OSPF Interface Administrative Status. The OSPF interface's administrative status. The value 'enabled' denotes that neighbor relationships may be formed on the interface, and the interface will be advertised as an internal route to some area. The value 'disabled' denotes that the interface is external to OSPF.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

fmOspfStandardIfRtrPriority 2.1.866.20.10.18.1.7.1.6
OSPF Interface Router Priority. The priority of this interface. Used in multi-access networks, this field is used in the designated router election algorithm. The value 0 signifies that the router is not eligible to become the designated router on this particular network. In the event of a tie in this value, routers will use their router id as a tie breaker
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmOspfStandardIfTransitDelay 2.1.866.20.10.18.1.7.1.7
OSPF Interface Transit Delay. The estimated number of seconds it takes to transmit a link- state update packet over this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..3600  

fmOspfStandardIfRetransInterval 2.1.866.20.10.18.1.7.1.8
OSPF Interface Retransmit Interval. The number of seconds between link-state advertisement retransmissions, for adjacencies belonging to this interface. This value is also used when retransmitting database description and link-state request packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..3600  

fmOspfStandardIfHelloInterval 2.1.866.20.10.18.1.7.1.9
OSPF Interface Hello Interval. The length of time, in seconds, between the Hello packets that the router sends on the interface. This value must be the same for all routers attached to a common network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fmOspfStandardIfRtrDeadInterval 2.1.866.20.10.18.1.7.1.10
OSPF Interface Dead Interval. The number of seconds that a router's Hello packets have not been seen before it's neighbors declare the router down. This should be some multiple of the Hello interval. This value must be the same for all routers attached to a common network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

fmOspfStandardIfPollInterval 2.1.866.20.10.18.1.7.1.11
OSPF Interface Poll Interval. The larger time interval, in seconds, between the Hello packets sent to an inactive non-broadcast multi- access neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

fmOspfStandardIfState 2.1.866.20.10.18.1.7.1.12
OSPF Interface State. The OSPF Interface State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), loopback(2), waiting(3), pointToPoint(4), designatedRouter(5), backupDesignatedRouter(6), otherDesignatedRouter(7)  

fmOspfStandardIfDesignatedRouter 2.1.866.20.10.18.1.7.1.13
OSPF Interface Designated Router. The IP Address of the Designated Router.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardIfBackupDesignatedRouter 2.1.866.20.10.18.1.7.1.14
OSPF Interface Backup Designated Router. The IP Address of the Backup Designated Router.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardIfEvents 2.1.866.20.10.18.1.7.1.15
OSPF Interface Events. The number of times this OSPF interface has changed its state, or an error has occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOspfStandardIfAuthKey 2.1.866.20.10.18.1.7.1.16
OSPF Interface Authentication Key. The Authentication Key. If the Area's Authorization Type is simplePassword, and the key length is shorter than 8 octets, the agent will left adjust and zero fill to 8 octets. When read, it always returns an Octet String of length zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

fmOspfStandardIfMetricTable 2.1.866.20.10.18.1.8
The TOS metrics for a non-virtual interface identified by the interface index.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOspfStandardIfMetricEntry

fmOspfStandardIfMetricEntry 2.1.866.20.10.18.1.8.1
An entry of fmOspfStandardIfMetricTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOspfStandardIfMetricEntry  

fmOspfStandardIfMetricIpAddress 2.1.866.20.10.18.1.8.1.1
OSPF Interface Metric Ip Address. The IP address of this OSPF interface. On row creation, this can be derived from the instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardIfMetricAddressLessIf 2.1.866.20.10.18.1.8.1.2
OSPF Interface Metric Address Less If. For the purpose of easing the instancing of addressed and addressless interfaces; This variable takes the value 0 on interfaces with IP Addresses, and the value of ifIndex for interfaces having no IP Address. On row creation, this can be derived from the instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmOspfStandardIfMetricTOS 2.1.866.20.10.18.1.8.1.3
OSPF Interface Metric TOS. The type of service metric being referenced. On row creation, this can be derived from the instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

fmOspfStandardIfMetricMetric 2.1.866.20.10.18.1.8.1.4
OSPF Interface Metric Metric. The metric of using this type of service on this interface. The default value of the TOS 0 Metric is 10^8 / ifSpeed. The value FFFF is distinguished to mean 'no route via this TOS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fmOspfStandardIfMetricStatus 2.1.866.20.10.18.1.8.1.5
ID FMSIPOSPF Interface Metric Status. This variable displays the validity or invalidity of the entry. Setting it to 'invalid' has the effect of rendering it inoperative. he internal effect (row removal) is implementation dependent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fmOspfStandardVirtIfTable 2.1.866.20.10.18.1.9
Information about this router's virtual interfaces.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOspfStandardVirtIfEntry

fmOspfStandardVirtIfEntry 2.1.866.20.10.18.1.9.1
An entry of fmOspfStandardVirtIfTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOspfStandardVirtIfEntry  

fmOspfStandardVirtIfAreaID 2.1.866.20.10.18.1.9.1.1
OSPF Virtual Interface Area ID. The Transit Area that the Virtual Link traverses. By definition, this is not 0.0.0.0
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardVirtIfNeighbor 2.1.866.20.10.18.1.9.1.2
OSPF Virtual Interface Neighbor. The Router ID of the Virtual Neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardVirtIfTransitDelay 2.1.866.20.10.18.1.9.1.3
OSPF Virtual Interface Transit Delay. The estimated number of seconds it takes to transmit a link- state update packet over this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..3600  

fmOspfStandardVirtIfRetransInterval 2.1.866.20.10.18.1.9.1.4
OSPF Virtual Interface Retransmit Interval. The number of seconds between link-state advertisement retransmissions, for adjacencies belonging to this interface. This value is also used when retransmitting database description and link-state request packets. This value should be well over the expected round-trip time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..3600  

fmOspfStandardVirtIfHelloInterval 2.1.866.20.10.18.1.9.1.5
OSPF Virtual Interface Hello Interval. The length of time, in seconds, between the Hello packets that the router sends on the interface. This value must be the same for the virtual neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fmOspfStandardVirtIfRtrDeadInterval 2.1.866.20.10.18.1.9.1.6
OSPF Virtual Interface Router Dead Interval. The number of seconds that a router's Hello packets have not been seen before it's neighbors declare the router down. This should be some multiple of the Hello interval. This value must be the same for the virtual neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

fmOspfStandardVirtIfState 2.1.866.20.10.18.1.9.1.7
OSPF Virtual Interface State. OSPF virtual interface states.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), pointToPoint(4)  

fmOspfStandardVirtIfEvents 2.1.866.20.10.18.1.9.1.8
OSPF Virtual Interface Events. The number of state changes or error events on this Virtual Link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOspfStandardVirtIfAuthKey 2.1.866.20.10.18.1.9.1.9
OSPF Virtual Interface Authentication Type. If Authentication Type is simplePassword, the device will left adjust and zero fill to 8 octets. When read, ospfVifAuthKey always returns a string of length zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

fmOspfStandardVirtIfStatus 2.1.866.20.10.18.1.9.1.10
OSPF Virtual Interface Status. This variable displays the validity or invalidity of the entry. Setting it to 'invalid' has the effect of rendering it inoperative. The internal effect (row removal) is implementation dependent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fmOspfStandardNbrTable 2.1.866.20.10.18.1.10
A table of non-virtual neighbor information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOspfStandardNbrEntry

fmOspfStandardNbrEntry 2.1.866.20.10.18.1.10.1
An entry of fmOspfStandardNbrTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOspfStandardNbrEntry  

fmOspfStandardNbrIpAddress 2.1.866.20.10.18.1.10.1.1
OSPF Neighbor Ip Address. The IP address of this neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardNbrAddressLessIndex 2.1.866.20.10.18.1.10.1.2
OSPF Neighbor Address Less Index. On an interface having an IP Address, zero. On addressless interfaces, the corresponding value of ifIndex in the Internet Standard MIB. On row creation, this can be derived from the instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..35  

fmOspfStandardNbrRtrId 2.1.866.20.10.18.1.10.1.3
OSPF Neighbor Router Id. A 32-bit integer (represented as a type IpAddress) uniquely identifying the neighboring router in the Autonomous System.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardNbrOptions 2.1.866.20.10.18.1.10.1.4
OSPF Neighbor Options. A Bit Mask corresponding to the neighbor's options field. Bit 0, if set, indicates that the area accepts and operates on external information; if zero, it is a stub area. Bit 1, if set, indicates that the system will operate on Type of Service metrics other than TOS 0. If zero, the neighbor will ignore all metrics except the TOS 0 metric.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmOspfStandardNbrPriority 2.1.866.20.10.18.1.10.1.5
OSPF Neighbor Priority. The priority of this neighbor in the designated router election algorithm. The value 0 signifies that the neighbor is not eligible to become the designated router on this particular network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmOspfStandardNbrState 2.1.866.20.10.18.1.10.1.6
OSPF Neighbor State. The State of the relationship with this Neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), attempt(2), init(3), twoWay(4), exchangeStart(5), exchange(6), loading(7), full(8)  

fmOspfStandardNbrEvents 2.1.866.20.10.18.1.10.1.7
OSPF Neighbor Events. The number of times this neighbor relationship has changed state, or an error has occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOspfStandardNbrLSRetransQLen 2.1.866.20.10.18.1.10.1.8
OSPF Neighbor LS Retransmit Queue Length. The current length of the retransmission queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmOspfStandardNBMANbrStatus 2.1.866.20.10.18.1.10.1.9
OSPF Neighbor Status. This variable displays the validity or invalidity of the entry. Setting it to 'invalid' has the effect of rendering it inoperative. The internal effect (row removal) is implementation dependent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fmOspfStandardVirtNbrTable 2.1.866.20.10.18.1.11
A table of virtual neighbor information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmOspfStandardVirtNbrEntry

fmOspfStandardVirtNbrEntry 2.1.866.20.10.18.1.11.1
An entry of fmOspfStandardVirtNbrTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmOspfStandardVirtNbrEntry  

fmOspfStandardVirtNbrArea 2.1.866.20.10.18.1.11.1.1
OSPF Virtual Neighbor Area. The Transit Area Identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardVirtNbrRtrId 2.1.866.20.10.18.1.11.1.2
OSPF Virtual Neighbor Router Id. A 32-bit integer uniquely identifying the neighboring router in the Autonomous System.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardVirtNbrIpAddr 2.1.866.20.10.18.1.11.1.3
OSPF Virtual Neighbor Ip Address. The IP address this Virtual Neighbor is using.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmOspfStandardVirtNbrOptions 2.1.866.20.10.18.1.11.1.4
OSPF Virtual Neighbor Options. A bit map corresponding to the neighbor's options field. Thus, Bit 1, if set, indicates that the neighbor supports Type of Service Routing; if zero, no metrics other than TOS 0 are in use by the neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fmOspfStandardVirtNbrState 2.1.866.20.10.18.1.11.1.5
OSPF Virtual Neighbor State. The state of the Virtual Neighbor Relationship.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), attempt(2), init(3), twoWay(4), exchangeStart(5), exchange(6), loading(7), full(8)  

fmOspfStandardVirtNbrEvents 2.1.866.20.10.18.1.11.1.6
OSPF Virtual Neighbor Events. The number of times this virtual link has changed its state, or an error has occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmOspfStandardVirtNbrLSRetransQLen 2.1.866.20.10.18.1.11.1.7
OSPF Virtual Neighbor LS Retransmit Queue Length. The current length of the retransmission queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fmUsersRights 2.1.866.20.10.20
OBJECT IDENTIFIER    

fmuVersionRight 2.1.866.20.10.20.1
OBJECT IDENTIFIER    

fmuVersMax 2.1.866.20.10.20.1.1
Version max autorisee
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..15  

fmuLineAccess 2.1.866.20.10.20.5
OBJECT IDENTIFIER    

fmuAccessLineNbMax 2.1.866.20.10.20.5.1
Nombre max de lignes autorises
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessX25PlsLineNbMax 2.1.866.20.10.20.5.2
Nombre max de lignes X25 PLS
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessX25MlpLineNbMax 2.1.866.20.10.20.5.3
Nombre max de lignes X25 MLP
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessAsynLineNbMax 2.1.866.20.10.20.5.4
Nombre max de lignes Asyn
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessVipLineNbMax 2.1.866.20.10.20.5.5
Nombre max de lignes VIP
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessSdlcLineNbMax 2.1.866.20.10.20.5.6
Nombre max de lignes SDLC
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessBsc3270LineNbMax 2.1.866.20.10.20.5.7
Nombre max de lignes BSC 3270
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessBsc2780LineNbMax 2.1.866.20.10.20.5.8
Nombre max de lignes BSC 2780/3780
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessBscTranspLineNbMax 2.1.866.20.10.20.5.9
Nombre max de lignes BSC transparent
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessRnisChannelBNbMax 2.1.866.20.10.20.5.10
Nombre de canaux B avec signalisation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessRnisChannelDNbMax 2.1.866.20.10.20.5.11
Nombre de canaux D
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessHdlcTranspLineNbMax 2.1.866.20.10.20.5.12
Nombre de lignes HDLC transparent
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessFrSuscribLineNbMax 2.1.866.20.10.20.5.13
Nombre de lignes Frame Relay abonne
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessFrPublicNetworkLineNbMax 2.1.866.20.10.20.5.14
Nombre de lignes Frame Relay parmi FRSE FRTE FRCE
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessFrseLineNbMax 2.1.866.20.10.20.5.15
Nombre max de lignes FR SE
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessX29ReroutLineNbMax 2.1.866.20.10.20.5.16
Nombre de lignes avec reroutage X29
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessCvfLineNbMax 2.1.866.20.10.20.5.17
Nombre de lignes abonnees CVF
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessX75LineNbMax 2.1.866.20.10.20.5.18
Nombre max de lignes X75
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessPaviLineNbMax 2.1.866.20.10.20.5.19
Nombre max de lignes PAVI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessX28PlusLineNbMax 2.1.866.20.10.20.5.20
Nombre max de lignes X28 Plus
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessPadLineNbMax 2.1.866.20.10.20.5.21
Nombre max de lignes PAD multinormes
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessPppaLineNbMax 2.1.866.20.10.20.5.22
Nombre max de lignes PPPA
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuAccessPppsLineNbMax 2.1.866.20.10.20.5.23
Nombre max de lignes PPPS
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

fmuFunctionRight 2.1.866.20.10.20.10
OBJECT IDENTIFIER    

fmuFunctionRouterAndBridge 2.1.866.20.10.20.10.1
Comlan bridge ou routeur
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER mcx104-64kbs(1), pont(2), routeurIP(3), pontAndRouteurIP(4)  

fmuFunctionMemTypeForMCXType4 2.1.866.20.10.20.10.2
Types de memoires (MCX type 4)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER flash2Mo-ram2Mo(1), flash4Mo-ram2Mo(2), flash2Mo-ram4Mo(3), flash4Mo-ram4Mo(4), obsolete-object(5)  

fmuFunctionAccessFrProtoco 2.1.866.20.10.20.10.3
Autorisation protocoles FRSNA FRIP FRI FRT
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

fmuFunctionBridgeAndStp 2.1.866.20.10.20.10.4
Fonction Pont et STP
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionIpRouter 2.1.866.20.10.20.10.5
Fonction Routeur IP
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionIpxRouter 2.1.866.20.10.20.10.6
Fonction Routeur IPX
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionClnpRouter 2.1.866.20.10.20.10.7
Fonction Routeur CLNP
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionLz77Compression 2.1.866.20.10.20.10.8
Compression LZ77
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionLz78Compression 2.1.866.20.10.20.10.9
Compression LZ78
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionSecurCard 2.1.866.20.10.20.10.10
Droit securise
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionLoadStat 2.1.866.20.10.20.10.11
Statistiques de charge
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionOverflowResc 2.1.866.20.10.20.10.12
Secours-debordement
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionPae 2.1.866.20.10.20.10.13
PAE
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionOnlineFileTransfer 2.1.866.20.10.20.10.14
Transfert de fichiers on line
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionDPacket 2.1.866.20.10.20.10.15
Paquet dans D
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionExploitMibUse 2.1.866.20.10.20.10.16
Droits d'utilisation de la MIB exploitation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmuFunctionLlcOnEthernet 2.1.866.20.10.20.10.17
Autorisation LLC sur Ethernet
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fmHardwareId 2.1.866.20.10.25
OBJECT IDENTIFIER    

fmhTechnicalsFeatures 2.1.866.20.10.25.1
OBJECT IDENTIFIER    

fmhTechnicEquipmType 2.1.866.20.10.25.1.1
Type de machine
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER lmx506-type1(1), mcx104(2), lmx506-3(3), mcx-type1(4), mcx-type2(5), lmx506-type2(6), mcx300B(7), mcx300H(8), cmd-chd(9), frx-msb2-1(10), frx-msb2-s2(11), vpb(12)  

fmhTechnicLineNb 2.1.866.20.10.25.1.2
Nombre de lignes
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 3..12  

fmhTechnicPromFlashSize 2.1.866.20.10.25.1.3
Taille de la PROM Flash
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER flash-512K(1), flash-768K(2), flash-1M(3), flash-1M256(4), flash-1M512(5), flash-1M768(6), flash-2M(7), flash-2M256(8), flash-2M512(9), flash-2M768(10), flash-3M(11), flash-3M256(12), flash-3M512(13), flash-3M768(14), flash-4M(15), flash-6M(16), flash-8M(17), flash-10M(18), flash-12M(19), flash-14M(20), flash-16M(21)  

fmhTechnicRamSize 2.1.866.20.10.25.1.4
Taille de la RAM
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ram-512K(1), ram-1M(2), ram-1M512(3), ram-2M(4), ram-4M(5), ram-8M(6), ram-16M(7), ram-32M(8)  

fmhTechnicEepromSize 2.1.866.20.10.25.1.5
Taille de l'EEPROM
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER eeprom-32K(1), eeprom-64K(2), eeprom-128K(3), eeprom-256K(4)  

fmhTechnicTransputerPresence 2.1.866.20.10.25.1.6
Presence Transputer
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notpresent(1), present(2)  

fmhTechnicEthernetPresence 2.1.866.20.10.25.1.7
Presence Ethernet
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notpresent(1), present(2)  

fmhTechnicTokenRingPresence 2.1.866.20.10.25.1.8
Presence Token Ring
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notpresent(1), present(2)  

fmhTechnicMacAdress 2.1.866.20.10.25.1.9
Adresse MAC
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

fmhEquipmentId 2.1.866.20.10.25.5
OBJECT IDENTIFIER    

fmhEqIdReference 2.1.866.20.10.25.5.1
Reference de l'equipement
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

fmhEqIdSerialNbEncodingType 2.1.866.20.10.25.5.2
Type de codage du numero de serie de l'equipement
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bcd(1), hexa(2)  

fmhEqIdSerialNb 2.1.866.20.10.25.5.3
Numero de serie de l'equipement
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

fmhEqIdFactoryReleaseDate 2.1.866.20.10.25.5.4
Date de sortie d'usine
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

fmhEqIdFirstFactoryReturnDate 2.1.866.20.10.25.5.5
Premiere date de retour usine
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

fmhEqIdSecondFactoryReturnDate 2.1.866.20.10.25.5.6
Deuxieme date de retour usine
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

fmhEqIdThirdFactoryReturnDate 2.1.866.20.10.25.5.7
Troisieme date de retour usine
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

fmhEqIdFourthFactoryReturnDate 2.1.866.20.10.25.5.8
Quatrieme date de retour usine
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

fmhEqIdFifthFactoryReturnDate 2.1.866.20.10.25.5.9
Cinquieme date de retour usine
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

fmhE1S2ModuleDescription 2.1.866.20.10.25.10
OBJECT IDENTIFIER    

fmhE1S2ModDescSoftwareVersion 2.1.866.20.10.25.10.1
Version logicielle
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

fmhE1S2ModDescHardwareVersion 2.1.866.20.10.25.10.2
Version materielle
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

fmsInverseArp 2.1.866.20.10.26
OBJECT IDENTIFIER    

fmsInArpVirtualPortTable 2.1.866.20.10.26.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsInArpVirtualPortEntry

fmsInArpVirtualPortEntry 2.1.866.20.10.26.1.1
An entry of fmsInArpVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsInArpVirtualPortEntry  

fmsInArpVpConnX121 2.1.866.20.10.26.1.1.1
X121 address on which an inverse ARP has been done.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

fmsInArpVpVirtualPortId 2.1.866.20.10.26.1.1.2
Virtual Port Identifier of the Inverse ARP statistic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fmsInArpVpOutRequests 2.1.866.20.10.26.1.1.3
Number of Inverse ARP request sent on this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsInArpVpInResponses 2.1.866.20.10.26.1.1.4
Number of Inverse ARP reply received on the connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsInArpVpInRequests 2.1.866.20.10.26.1.1.5
Number of Inverse ARP request received on the connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsInArpVpOutResponses 2.1.866.20.10.26.1.1.6
Number of Inverse ARP reply sent on the connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsInArpVpInverseArpStatus 2.1.866.20.10.26.1.1.7
State of the inverse ARP resolution.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unsuccessful(1), successful(2)  

fmsInArpVpRemoteIpAddr 2.1.866.20.10.26.1.1.8
Associated remote IP address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmsInArpVpLocalIpAddr 2.1.866.20.10.26.1.1.9
Associated local IP address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmsBootP 2.1.866.20.10.27
OBJECT IDENTIFIER    

fmsBootPClient 2.1.866.20.10.27.1
OBJECT IDENTIFIER    

fmsBootPClientStatus 2.1.866.20.10.27.1.1
The value of this object identifies result of BootP transaction.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notLaunched(1), inProgress(2), succeed(3), failed(4)  

fmsBootPClientFileName 2.1.866.20.10.27.1.2
The value of this object identifies the file name received after bootreply reception.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

fmsBootPClientServerIpAddr 2.1.866.20.10.27.1.3
The value of this object identifies the server IP address which has contacted bootp client manager.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmsBootPClientGatewayIpAddr 2.1.866.20.10.27.1.4
The value of this object identifies the gateway IP address. This field is used in optional cross-gateway booting.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmsBootPRelayTable 2.1.866.20.10.27.10
This table describes the parameters used in BootP Relay mode. It gives statistics of BootP packets transfers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmsBootPRelayEntry

fmsBootPRelayEntry 2.1.866.20.10.27.10.1
An entry of fmsBootPRelayTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmsBootPRelayEntry  

fmsBootPRelayVirtualPortId 2.1.866.20.10.27.10.1.1
The value of this object identifies the Virtual Port Identifier of BootP Relay statistic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

fmsBootPRelayRelayedPkts 2.1.866.20.10.27.10.1.2
The value of this object identifies the number of packets routed by gateway in the case of BootP Relay mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsBootPRelayDroppedPkts 2.1.866.20.10.27.10.1.3
The value of this object identifies the number of destroyed packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsBootPRelayRecRequests 2.1.866.20.10.27.10.1.4
The value of this object identifies the number of received packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fmsBootPRelayRecReplies 2.1.866.20.10.27.10.1.5
The value of this object identifies the number of received responses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

frxStateChange 5
A frxStateChange trap signifies that a outstanding events takes place. This event is not in frxNodeStateChange, frxLineStateChange, frxLoadAndTrafficEvent, frxManagementEvent, frxServicesStateChange.
TRAP-TYPE    

frxNodeStateChange 6
A frxNodeStateChange trap signifies that a state changing takes place in the equipment or in a module.
TRAP-TYPE    

frxLineStateChange 7
A frxLineStateChange trap signifies that a state changing takes place over a SLL (Switched Logical Link), over the level 2 or 3 protocol of the line. It can indicate a charge overflow of the line.
TRAP-TYPE    

frxLoadAndTrafficEvent 8
A frxLoadAndTrafficEvent trap signifies that the maximum threshold, like the number of virtual circuits, the data frame rejection threshold ..., is reached.
TRAP-TYPE    

frxManagementEvent 9
A frxManagementEvent trap signifies that a configuration changing takes place or someone behaves on the system.
TRAP-TYPE    

frxServicesStateChange 10
A frxServicesStateChange trap signifies that something about additional services (securized virtual circuit, compression, regrouping frames) takes place.
TRAP-TYPE    

fdPhysicalPorts 2.1.866.20.20.10
OBJECT IDENTIFIER    

fdpIdentification 2.1.866.20.20.10.1
OBJECT IDENTIFIER    

fdpIdentPhysPortId 2.1.866.20.20.10.1.1
The value of this object is the physical port number. This value may be modified only if fdpIdentPhysPortState is 'notConfigured', 'up' or 'down'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..35  

fdpIdentPhysPortState 2.1.866.20.20.10.1.3
The value of this object is the state of the physical port identified by fdpIdentPhysPortId.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notConfigured(1), up(2), down(3), loopBack0(10), loopBack3(11), remoteLoopBack2(12), modemManagement(13)  

fdpControl 2.1.866.20.20.10.2
OBJECT IDENTIFIER    

fdpCtrlCommand 2.1.866.20.20.10.2.1
The value of this object is the desired state of the physical port described in fdpIdentPhysPortId. The equipment answers always with the value 'ready' to a GetRequest on this object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), up(2), down(3)  

fdpCtrlDiagCode 2.1.866.20.20.10.2.10
The value of this object is the result of the last SET on fdpCtrlCommand.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noError(1), unknownCommand(2), noSuchPhysPortId(3), noSuchPhysPortType(4), badLoopBackType(5), deviceDown(6), physPortIsTheLinkToManager(7), physPortNotMonitored(8)  

fdpTest 2.1.866.20.20.10.3
OBJECT IDENTIFIER    

fdpTestLoopBackType 2.1.866.20.20.10.3.1
The value of this object is the desired loop type run on the physical port described in fdpIdentPhysPortId.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER loopBack0(1), loopBack3(2), remoteLoopBack2(3)  

fdpTestOutputPacketsCount 2.1.866.20.20.10.3.2
The value of this object is the maximum number of messages to be sent during the test. '0' means 'infinite'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

fdpTestMaxDuration 2.1.866.20.20.10.3.3
The value of this object is the maximum duration of the test in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..90  

fdpTestCommand 2.1.866.20.20.10.3.4
The value of this object permits to start or stop the loop test described in fdpTestLoopBackType, fdpTestOutputPacketsCount and fdpTestMaxDuration. The equipment answers always with the value 'ready' to a GetRequest on this object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), start(2), stop(3)  

fdpTestDiagCode 2.1.866.20.20.10.3.10
The value of this object is the result of the last SET on fdpTestCommand.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noError(1), unknownCommand(2), noSuchPhysPortId(3), noSuchPhysPortType(4), badLoopBackType(5), deviceDown(6), physPortIsTheLinkToManager(7), physPortNotMonitored(8), testInProgress(20), noTestInProgress(21), testStopped(22), waitingFirstStatusReport(23), atLeastOneInputErrPacket(24), atLeastOneLostPacket(25), atLeastOneFailedOutputPacket(26), noTestIndicator142(27), unavailableTest(28), loopBackBeforeTimeOut(29), loopBackOk(30)  

fdpTestState 2.1.866.20.20.10.3.11
The value of this object is the state of the last test started.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ready(1), waitingFirstStatusReport(2), waitingLastStatusReport(3)  

fdpTestOutPktsCounter 2.1.866.20.20.10.3.12
The value of this object is the number of messages sent during the test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fdpTestInPktsCounter 2.1.866.20.20.10.3.13
The value of this object is the number of messages received during the test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fdpTestInErrPktsCounter 2.1.866.20.20.10.3.14
The value of this object is the number of incorrect messages received during the test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fdpTestInErrOctetsCounter 2.1.866.20.20.10.3.15
The value of this object is the number of incorrect characters received during the test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

fdpModemManagement 2.1.866.20.20.10.4
OBJECT IDENTIFIER    

fdpModCommand 2.1.866.20.20.10.4.1
The value of this object permits to open or close a session with a modem connected on the physical port described in fdpIdentPhysPortId. The equipment answers always with the value 'ready' to a GetRequest on this object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), open(2), close(3)  

fdpModControlData 2.1.866.20.20.10.4.2
The value of this object is AT Commands to be sent to the modem
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

fdpModDiagCode 2.1.866.20.20.10.4.10
The value of this object is the result of the last SET on fdpModCommand or fdpModControlData. The value 'modemData' means that the modem has sent one or several responses which may be seen in fdpModResponseTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noError(1), unknownCommand(2), noSuchPhysPortId(3), noSuchPhysPortType(4), badLoopBackType(5), deviceDown(6), physPortIsTheLinkToManager(7), physPortNotMonitored(8), openingSequence(40), modemStabilization(41), sequenceOpen(42), noResponseFromModem(43), noSequenceOpen(44), sequenceAlreadyOpen(45), modemData(46), openingSequenceWithoutAtCommand(47)  

fdpModResponseTable 2.1.866.20.20.10.4.15
This table contents the result of the last AT commands described in fdpModControlData.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FdpModResponseEntry

fdpModResponseEntry 2.1.866.20.20.10.4.15.1
An entry of fdpModResponseTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FdpModResponseEntry  

fdpModRespEltNum 2.1.866.20.20.10.4.15.1.1
The value of this object is the identifier of one text line of a response of the modem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..32  

fdpModRespElement 2.1.866.20.20.10.4.15.1.2
The value of this object contains the ASCII characters of this text line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpcDiagnostic 2.1.866.51.20
OBJECT IDENTIFIER    

cdPhysicalPorts 2.1.866.51.20.10
OBJECT IDENTIFIER    

cdpIdentification 2.1.866.51.20.10.1
OBJECT IDENTIFIER    

cdpIdentPhysPortType 2.1.866.51.20.10.1.2
Physical port type
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), synchronous(2), asynchronous(3)  

cpcManagement 2.1.866.51.10
OBJECT IDENTIFIER    

cmEvents 2.1.866.51.10.5
OBJECT IDENTIFIER    

cmeEventSynchronize 2.1.866.51.10.5.4
Action.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER node(1), local(2)  

cmeClearVirtualCircuitInfo 2.1.866.51.10.5.5
OBJECT IDENTIFIER    

cmeClearX121Address 2.1.866.51.10.5.5.1
The value of this object is the X121 address of the remote equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

cmeClearCallUserData 2.1.866.51.10.5.5.2
The value of this object is the call user data send to the Compac management function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

cmeClearEvent 2.1.866.51.10.5.5.3
The value of this object is the type of X25 failed connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER timeout(1), x25ClearReceived(2)  

cmeClearCause 2.1.866.51.10.5.5.4
The value of this object is the X25 clear cause number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cmeClearDiag 2.1.866.51.10.5.5.5
The value of this object is the X25 clear diagnostic number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cmeClearTimeStamp 2.1.866.51.10.5.5.6
The value of this object is the sysUpTime at last disconnection time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

cpcFileTransfer 2.1.866.51.30
OBJECT IDENTIFIER    

cfFileTransferService 2.1.866.51.30.1
File Transfer Service
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER softwareIdentification(1), configurationDownloading(2), offLineSoftwareDownloading(3), configurationUploading(4), equipmentReset(5), equipmentHalt(6), hardwareIdentification(7), softwareList(8), onLineSoftwareDownloading(9), onLineSoftwareDownloadingAndReset(10)  

cfConfigurationFileToDownload 2.1.866.51.30.2
Name of configuration file to download
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfConfigurationFileToUpload 2.1.866.51.30.3
Name of file in which configuration will be uploaded
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfSoftwareFileToDownload 2.1.866.51.30.4
Name of software file to download
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfStartUpChoiceAfterReset 2.1.866.51.30.5
Choice of start up after reset
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER withDefaultConfiguration(1), withCopyOfDefaultToOperational(2), withOperationalConfiguration(3)  

cfModuleToIdentify 2.1.866.51.30.6
Selection of module for hardware identification
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER module0(1), module1(2), module2(3), calledModule(4)  

cfZoneToIdentify 2.1.866.51.30.7
Selection of zone for hardware identification
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER manufacturerZone(1), customerZone(2)  

cfHardwareIdentificationPassword 2.1.866.51.30.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfSoftwareListPassword 2.1.866.51.30.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfServiceReport 2.1.866.51.30.10
Report after service execution
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normalEndOfService(1), abnormalEndOfService(2), sessionOpened(3), sessionCleared(4)  

cfVersion 2.1.866.51.30.11
Version of equipment returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfRevision 2.1.866.51.30.12
Revision of equipment returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfEdition 2.1.866.51.30.13
Edition of equipment returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfCpuBoardType 2.1.866.51.30.14
Type of CPU board returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfProductType 2.1.866.51.30.15
Type of product returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfConfigurationVersion 2.1.866.51.30.16
Version of configuration returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfConfigurationRelease 2.1.866.51.30.17
Release of configuration returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfConfigurationEdition 2.1.866.51.30.18
Edition of configuration returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfConfigurationDate 2.1.866.51.30.19
Date of configuration returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cfUserField 2.1.866.51.30.20
User field returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cf12NcNumber35 2.1.866.51.30.21
12NC Number in 35xxxx returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..13)  

cf12NcNumber75 2.1.866.51.30.22
12NC Number in 75xxxx returned by software identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..13)  

cfField1 2.1.866.51.30.23
Field 1 returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..9)  

cfField2 2.1.866.51.30.24
Field 2 returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..9)  

cfField3 2.1.866.51.30.25
Field 3 returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..9)  

cfField4 2.1.866.51.30.26
Field 4 returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..9)  

cfFlashSize 2.1.866.51.30.27
Flash size returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..6)  

cfRamSize 2.1.866.51.30.28
RAM size returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..6)  

cfEepromSize 2.1.866.51.30.29
EEPROM size returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..6)  

cfNumberOfLines 2.1.866.51.30.30
Number of lines returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfTransputerPresence 2.1.866.51.30.31
Presence of transputer on board returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

cfMpbBoardReference255 2.1.866.51.30.32
Reference 255xxxx of the MPB returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfMpbBoardSerialNumber 2.1.866.51.30.33
Serial number of the MPB board returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfMtbBoardReference255 2.1.866.51.30.34
Reference 255xxxx of the MTB returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfMtbBoardSerialNumber 2.1.866.51.30.35
Serial number of the MTB board returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfReleaseDate 2.1.866.51.30.36
Release date returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfFactoryReturnDate1 2.1.866.51.30.37
Factory return date number 1 returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfFactoryReturnDate2 2.1.866.51.30.38
Factory return date number 2 returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfFactoryReturnDate3 2.1.866.51.30.39
Factory return date number 3 returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfFactoryReturnDate4 2.1.866.51.30.40
Factory return date number 4 returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfFactoryReturnDate5 2.1.866.51.30.41
Factory return date number 5 returned by hardware identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cfSoftwareList 2.1.866.51.30.42
List of software (user's right)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..2048)  

cpcClearVirtualCircuitEvent 100
A cpcClearVirtualCircuitEvent trap signifies a X25 failed connection between proxy agent and remote equipment.
TRAP-TYPE    

vcControl 2.1.866.30.1.1
OBJECT IDENTIFIER    

vcCtlDate 2.1.866.30.1.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

vcCtlHour 2.1.866.30.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

vcCtlConfigCom 2.1.866.30.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), check(2), load(5), save(6), hotReset(10)  

vcCtlConfigLoad 2.1.866.30.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..9  

vcCtlErrorTable 2.1.866.30.1.1.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcCtlErrorEntry

vcCtlErrorEntry 2.1.866.30.1.1.10.1
An entry of vcCtlErrorTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcCtlErrorEntry  

vcCtlErrorIndex 2.1.866.30.1.1.10.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

vcCtlErrorCode 2.1.866.30.1.1.10.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

vcCtlErrorMessage 2.1.866.30.1.1.10.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

vcCtlErrorTime 2.1.866.30.1.1.10.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

vcSystem 2.1.866.30.1.5
OBJECT IDENTIFIER    

vcSysConfActive 2.1.866.30.1.5.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s1(1), s2(2), s3(3), s4(4), s5(5), s6(6), s7(7), s8(8), s9(9), w0(10), w1(11), w2(12), w3(13), w4(14), w5(15), w6(16), w7(17), w8(18), w9(19), w0-1(20), w0-2(21), w0-3(22), w0-4(23), w0-5(24), w0-6(25), w0-7(26), w0-8(27), w0-9(28)  

vcSysConfDate 2.1.866.30.1.5.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

vcSysConfHour 2.1.866.30.1.5.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

vcManagement 2.1.866.30.1.10
OBJECT IDENTIFIER    

vcmAlrmGenTable 2.1.866.30.1.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcmAlrmGenEntry

vcmAlrmGenEntry 2.1.866.30.1.10.1.1
An entry of vcmAlrmGenTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcmAlrmGenEntry  

vcmAlrmGenFamilyId 2.1.866.30.1.10.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9)  

vcmAlrmGenTyp 2.1.866.30.1.10.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER lnkReady208(1), lnkNotReady209(2), fatalError222(3), reboot233(4)  

vcmAlrmGenTrapSend 2.1.866.30.1.10.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmGenDisplay 2.1.866.30.1.10.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmSCTable 2.1.866.30.1.10.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcmAlrmSCEntry

vcmAlrmSCEntry 2.1.866.30.1.10.2.1
An entry of vcmAlrmSCTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcmAlrmSCEntry  

vcmAlrmSCFamilyId 2.1.866.30.1.10.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9)  

vcmAlrmSCTyp 2.1.866.30.1.10.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER scReady210(1), scNotReady211(2), frAddrError223(3), dlciError224(4), scNotFree225(5), scDynamic226(6), scReinit227(7), unexpectedFrame230(8)  

vcmAlrmSCTrapSend 2.1.866.30.1.10.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmSCDisplay 2.1.866.30.1.10.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmVCTable 2.1.866.30.1.10.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcmAlrmVCEntry

vcmAlrmVCEntry 2.1.866.30.1.10.3.1
An entry of vcmAlrmVCTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcmAlrmVCEntry  

vcmAlrmVCFamilyId 2.1.866.30.1.10.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9)  

vcmAlrmVCTyp 2.1.866.30.1.10.3.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vcReady212(1), vcNotReady213(2), lossOfSync220(3), syncBack221(4), vcRejected231(5), endOfReject232(6)  

vcmAlrmVCTrapSend 2.1.866.30.1.10.3.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmVCDisplay 2.1.866.30.1.10.3.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmLMITable 2.1.866.30.1.10.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcmAlrmLMIEntry

vcmAlrmLMIEntry 2.1.866.30.1.10.4.1
An entry of vcmAlrmLMITable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcmAlrmLMIEntry  

vcmAlrmLMIFamilyId 2.1.866.30.1.10.4.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9)  

vcmAlrmLMITyp 2.1.866.30.1.10.4.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dcnxLmi234(1), cnxLmi235(2), lmiDlciNotConf236(3), lmiIntError237(4)  

vcmAlrmLMITrapSend 2.1.866.30.1.10.4.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmLMIDisplay 2.1.866.30.1.10.4.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmSwTable 2.1.866.30.1.10.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcmAlrmSwEntry

vcmAlrmSwEntry 2.1.866.30.1.10.5.1
An entry of vcmAlrmSwTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcmAlrmSwEntry  

vcmAlrmSwFamilyId 2.1.866.30.1.10.5.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9)  

vcmAlrmSwTyp 2.1.866.30.1.10.5.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER outgoingCall238(1), incomingCall239(2), localDisc240(3), remoteDisc241(4), backup242(5)  

vcmAlrmSwTrapSend 2.1.866.30.1.10.5.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmSwDisplay 2.1.866.30.1.10.5.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmCmpTable 2.1.866.30.1.10.6
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcmAlrmCmpEntry

vcmAlrmCmpEntry 2.1.866.30.1.10.6.1
An entry of vcmAlrmCmpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcmAlrmCmpEntry  

vcmAlrmCmpFamilyId 2.1.866.30.1.10.6.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9)  

vcmAlrmCmpTyp 2.1.866.30.1.10.6.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER compOn214(1), compOff215(2), algoCompNotOk228(3), algoCompOk229(4)  

vcmAlrmCmpTrapSend 2.1.866.30.1.10.6.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmCmpDisplay 2.1.866.30.1.10.6.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmFaxTable 2.1.866.30.1.10.7
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcmAlrmFaxEntry

vcmAlrmFaxEntry 2.1.866.30.1.10.7.1
An entry of vcmAlrmFaxTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcmAlrmFaxEntry  

vcmAlrmFaxFamilyId 2.1.866.30.1.10.7.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9)  

vcmAlrmFaxTyp 2.1.866.30.1.10.7.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER faxStart218(1), faxEnd219(2)  

vcmAlrmFaxTrapSend 2.1.866.30.1.10.7.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmFaxDisplay 2.1.866.30.1.10.7.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmTftpTable 2.1.866.30.1.10.8
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcmAlrmTftpEntry

vcmAlrmTftpEntry 2.1.866.30.1.10.8.1
An entry of vcmAlrmTftpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcmAlrmTftpEntry  

vcmAlrmTftpFamilyId 2.1.866.30.1.10.8.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9)  

vcmAlrmTftpTyp 2.1.866.30.1.10.8.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dwnStart243(1), dwnEnd244(2), dwnError245(3)  

vcmAlrmTftpTrapSend 2.1.866.30.1.10.8.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmTftpDisplay 2.1.866.30.1.10.8.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmSvcTable 2.1.866.30.1.10.9
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcmAlrmSvcEntry

vcmAlrmSvcEntry 2.1.866.30.1.10.9.1
An entry of vcmAlrmSvcTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcmAlrmSvcEntry  

vcmAlrmSvcFamilyId 2.1.866.30.1.10.9.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9)  

vcmAlrmSvcTyp 2.1.866.30.1.10.9.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER svcOutCall246(1), svcInCall247(2), svcLocalConnect248(3), svcLocalDisc249(4), svcRemoteDisc250(5), svcOutFailCall251(6), svcInFailCall252(7)  

vcmAlrmSvcTrapSend 2.1.866.30.1.10.9.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcmAlrmSvcDisplay 2.1.866.30.1.10.9.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcInterfaces 2.1.866.30.1.15
OBJECT IDENTIFIER    

vcfPhysicalPortTable 2.1.866.30.1.15.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcfPhysicalPortEntry

vcfPhysicalPortEntry 2.1.866.30.1.15.1.1
An entry of vcfPhysicalPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcfPhysicalPortEntry  

vcfPhysPortId 2.1.866.30.1.15.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER l0(1), l1(2), frontPannel(3)  

vcfPhysPortConnector 2.1.866.30.1.15.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER db15V11(1), db15V28(2), din(3)  

vcfNumericLines 2.1.866.30.1.15.5
OBJECT IDENTIFIER    

vcfNumericLineTable 2.1.866.30.1.15.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcfNumericLineEntry

vcfNumericLineEntry 2.1.866.30.1.15.5.1.1
An entry of vcfNumericLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcfNumericLineEntry  

vcfNumericLineInterfaceId 2.1.866.30.1.15.5.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER l0(1), l1(2), frontPannel(3)  

vcfNumericLineType 2.1.866.30.1.15.5.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dataLine(1), configurationLine(2), debug(3)  

vcfDataLineTable 2.1.866.30.1.15.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcfDataLineEntry

vcfDataLineEntry 2.1.866.30.1.15.5.2.1
An entry of vcfDataLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcfDataLineEntry  

vcfDataLineInterfaceId 2.1.866.30.1.15.5.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER l0(1), l1(2)  

vcfDataLineRate 2.1.866.30.1.15.5.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s4800(1), s9600(2), s19200(3), s38400(4), s48000(5), s56000(6), s64000(7), s72000(8), s128000(9), s144000(10), s256000(11), s512000(12)  

vcfDataLineRts105 2.1.866.30.1.15.5.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), used(2), standard(3), off(4), on(5)  

vcfDataLineDtr108 2.1.866.30.1.15.5.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), used(2), standard(3), off(4), on(5)  

vcfDataLineCts106 2.1.866.30.1.15.5.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), used(2), standard(3), off(4), on(5)  

vcfDataLineDsr107 2.1.866.30.1.15.5.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), used(2), standard(3), off(4), on(5)  

vcfDataLineDcd109 2.1.866.30.1.15.5.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), used(2), standard(3), off(4), on(5)  

vcfConfLineTable 2.1.866.30.1.15.5.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcfConfLineEntry

vcfConfLineEntry 2.1.866.30.1.15.5.3.1
An entry of vcfConfLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcfConfLineEntry  

vcfConfLineInterfaceId 2.1.866.30.1.15.5.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER l0(1), l1(2), frontPannel(3)  

vcfConfLineRate 2.1.866.30.1.15.5.3.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER s4800(1), s9600(2), s19200(3), s38400(4), s48000(5), s56000(6), s64000(7), s72000(8), s128000(9), s144000(10), s256000(11), s512000(12)  

vcFrameRelaySw 2.1.866.30.1.20
OBJECT IDENTIFIER    

vcFrSwitchingTable 2.1.866.30.1.20.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcFrSwitchingEntry

vcFrSwitchingEntry 2.1.866.30.1.20.1.1
An entry of vcFrSwitchingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcFrSwitchingEntry  

vcFrSwL0Dlci 2.1.866.30.1.20.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1022  

vcFrSwL1Dlci 2.1.866.30.1.20.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1022  

vcFrSwStatus 2.1.866.30.1.20.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcFrSwL0DlciPriority 2.1.866.30.1.20.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER highPriority(1), lowPriority(2)  

vcFrSwL0MuxEnable 2.1.866.30.1.20.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcFrSwL0ChanelIdentifierCID 2.1.866.30.1.20.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..63  

vcFrSwL1DlciPriority 2.1.866.30.1.20.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER highPriority(1), lowPriority(2)  

vcFrSwL1MuxEnable 2.1.866.30.1.20.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcFrSwL1ChanelIdentifierCID 2.1.866.30.1.20.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..63  

vcLogicalPorts 2.1.866.30.1.25
OBJECT IDENTIFIER    

vclLogicalPortTable 2.1.866.30.1.25.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VclLogicalPortEntry

vclLogicalPortEntry 2.1.866.30.1.25.1.1
An entry of vclLogicalPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VclLogicalPortEntry  

vclLogPortId 2.1.866.30.1.25.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vclLogPortStatus 2.1.866.30.1.25.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vclLogPortType 2.1.866.30.1.25.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER hdlc(1), frCe(2), frTe(3), frSe(4)  

vclHdlcAccessLogPort 2.1.866.30.1.25.5
OBJECT IDENTIFIER    

vclHdlcLogPortTable 2.1.866.30.1.25.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VclHdlcLogPortEntry

vclHdlcLogPortEntry 2.1.866.30.1.25.5.1.1
An entry of vclHdlcLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VclHdlcLogPortEntry  

vclHdlcLpLogPortId 2.1.866.30.1.25.5.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vclHdlcLpFragmentationLength 2.1.866.30.1.25.5.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 60..390  

vclHdlcLpRemoteAddress 2.1.866.30.1.25.5.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

vclFrameRelay 2.1.866.30.1.25.10
OBJECT IDENTIFIER    

vclFrCommunicationEquipment 2.1.866.30.1.25.10.1
OBJECT IDENTIFIER    

vclFrCeLogPortTable 2.1.866.30.1.25.10.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VclFrCeLogPortEntry

vclFrCeLogPortEntry 2.1.866.30.1.25.10.1.1.1
An entry of vclFrCeLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VclFrCeLogPortEntry  

vclFrCeLpLogPortId 2.1.866.30.1.25.10.1.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vclFrCeLpInterfaceId 2.1.866.30.1.25.10.1.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER l0(1), l1(2)  

vclFrTerminalEquipment 2.1.866.30.1.25.10.2
OBJECT IDENTIFIER    

vclFrTeLogPortTable 2.1.866.30.1.25.10.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VclFrTeLogPortEntry

vclFrTeLogPortEntry 2.1.866.30.1.25.10.2.1.1
An entry of vclFrTeLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VclFrTeLogPortEntry  

vclFrTeLpLogPortId 2.1.866.30.1.25.10.2.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vclFrTeLpInterfaceId 2.1.866.30.1.25.10.2.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER l0(1), l1(2)  

vclFrTeLpConfigId 2.1.866.30.1.25.10.2.1.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vclFrTeLpLmi 2.1.866.30.1.25.10.2.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), lmiUni(2)  

vclFrSwitchEquipment 2.1.866.30.1.25.10.3
OBJECT IDENTIFIER    

vclFrSeLogPortTable 2.1.866.30.1.25.10.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VclFrSeLogPortEntry

vclFrSeLogPortEntry 2.1.866.30.1.25.10.3.1.1
An entry of vclFrSeLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VclFrSeLogPortEntry  

vclFrSeLpLogPortId 2.1.866.30.1.25.10.3.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vclFrSeLpInterfaceId 2.1.866.30.1.25.10.3.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER l0(1), l1(2)  

vclFrSeLpConfigId 2.1.866.30.1.25.10.3.1.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vclFrConfigurationTe 2.1.866.30.1.25.10.4
OBJECT IDENTIFIER    

vclFrLmiParameterTable 2.1.866.30.1.25.10.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VclFrLmiParameterEntry

vclFrLmiParameterEntry 2.1.866.30.1.25.10.4.1.1
An entry of vclFrLmiParameterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VclFrLmiParameterEntry  

vclFrLmiParaConfigId 2.1.866.30.1.25.10.4.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vclFrLmiParaDlci 2.1.866.30.1.25.10.4.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1023  

vclFrLmiParaStandard 2.1.866.30.1.25.10.4.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ansiT1-617d(1), itutQ933a(2)  

vclFrLmiParaAccessibilityCondition 2.1.866.30.1.25.10.4.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..10  

vclFrLmiParaN391FullStatusPollCount 2.1.866.30.1.25.10.4.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

vclFrLmiParaN392ErrorThreshold 2.1.866.30.1.25.10.4.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

vclFrLmiParaN393MonitoredEventCount 2.1.866.30.1.25.10.4.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

vclFrLmiParaT391LinkIntegPollTimer 2.1.866.30.1.25.10.4.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

vclFrConfigurationSe 2.1.866.30.1.25.10.5
OBJECT IDENTIFIER    

vclFrSeSignallingTable 2.1.866.30.1.25.10.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VclFrSeSignallingEntry

vclFrSeSignallingEntry 2.1.866.30.1.25.10.5.1.1
An entry of vclFrSeSignallingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VclFrSeSignallingEntry  

vclFrSeSigConfigId 2.1.866.30.1.25.10.5.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vclFrSeSigOuputTimeout 2.1.866.30.1.25.10.5.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..51000  

vclFrSeSigSignalOutputWinSize 2.1.866.30.1.25.10.5.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

vclFrSeSigN200RetransMaxCount 2.1.866.30.1.25.10.5.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

vclFrSeSigT200RetransTimer 2.1.866.30.1.25.10.5.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..25500  

vclFrSeSigT203InactivityTimer 2.1.866.30.1.25.10.5.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

vclFrSeSigT303SetupResponseTimer 2.1.866.30.1.25.10.5.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

vclFrSeSigT305DisconnectResponseTimer 2.1.866.30.1.25.10.5.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

vclFrSeSigT308ReleaseResponseTimer 2.1.866.30.1.25.10.5.1.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

vclFrSeSigT310CallProceedingTimer 2.1.866.30.1.25.10.5.1.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

vclFrSeSigT316RestartAcknowledgeTimer 2.1.866.30.1.25.10.5.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

vcWanSwitch 2.1.866.30.1.30
OBJECT IDENTIFIER    

vcwEquipParams 2.1.866.30.1.30.1
OBJECT IDENTIFIER    

vcwEquipDnicZoAddr 2.1.866.30.1.30.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

vcwEquipVoiceRoutingServicePortAddr 2.1.866.30.1.30.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

vcwEquipIpVirtualPortAddr 2.1.866.30.1.30.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

vcwEquipRemoteConfPortAddr 2.1.866.30.1.30.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

vcwEquipVoiceVirtualPortAddr 2.1.866.30.1.30.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

vcwEquipSVCDisconnectOnCongestion 2.1.866.30.1.30.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcwEquipOutLogPort 2.1.866.30.1.30.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

vcwABPvcLpTable 2.1.866.30.1.30.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcwABPvcLpEntry

vcwABPvcLpEntry 2.1.866.30.1.30.2.1
An entry of vcwABPvcLpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcwABPvcLpEntry  

vcwABPvcLpId 2.1.866.30.1.30.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vcwABPvcLpAddress 2.1.866.30.1.30.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

vcwWanRouteTable 2.1.866.30.1.30.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcwWanRouteEntry

vcwWanRouteEntry 2.1.866.30.1.30.3.1
An entry of vcwWanRouteTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcwWanRouteEntry  

vcwWanRouteDnicZoAddress 2.1.866.30.1.30.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

vcwWanRouteStatus 2.1.866.30.1.30.3.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcwWanRouteLogPortId 2.1.866.30.1.30.3.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

vcVirtualPorts 2.1.866.30.1.35
OBJECT IDENTIFIER    

vcvVirtualPortTable 2.1.866.30.1.35.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvVirtualPortEntry

vcvVirtualPortEntry 2.1.866.30.1.35.1.1
An entry of vcvVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvVirtualPortEntry  

vcvVirtualPortId 2.1.866.30.1.35.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vpVoix(1), vpIp(2)  

vcvIpVirtualPort 2.1.866.30.1.35.5
OBJECT IDENTIFIER    

vcvIpLocalTable 2.1.866.30.1.35.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvIpLocalEntry

vcvIpLocalEntry 2.1.866.30.1.35.5.1.1
An entry of vcvIpLocalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvIpLocalEntry  

vcvIpLocVirtualPortId 2.1.866.30.1.35.5.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vpVoix(1), vpIp(2)  

vcvIpLocAddressHost 2.1.866.30.1.35.5.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

vcvIpLocSubNetMask 2.1.866.30.1.35.5.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

vcvIpLocMtu 2.1.866.30.1.35.5.1.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 576..9180  

vcvIpLocRouteNextHop 2.1.866.30.1.35.5.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

vcvIpLocMinimumRecallTimer 2.1.866.30.1.35.5.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

vcvIpLocSvcClearCallTimer 2.1.866.30.1.35.5.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

vcvIpLocSvcCallRetryCount 2.1.866.30.1.35.5.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

vcvSnmp 2.1.866.30.1.35.5.5
OBJECT IDENTIFIER    

vcvSnmpGen 2.1.866.30.1.35.5.5.1
OBJECT IDENTIFIER    

vcvSnmpGenVirtualPortId 2.1.866.30.1.35.5.5.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER vpVoix(1), vpIp(2)  

vcvSnmpGenCommunityStringReadOnly 2.1.866.30.1.35.5.5.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..14)  

vcvSnmpGenCommunityStringReadWrite 2.1.866.30.1.35.5.5.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..14)  

vcvSnmpGenCommunityStringTrap 2.1.866.30.1.35.5.5.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..14)  

vcvSnmpGenAuthenticationFailureTrap 2.1.866.30.1.35.5.5.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

vcvSnmpManagerTable 2.1.866.30.1.35.5.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvSnmpManagerEntry

vcvSnmpManagerEntry 2.1.866.30.1.35.5.5.2.1
An entry of vcvSnmpManagerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvSnmpManagerEntry  

vcvSnmpManagerIpAddress 2.1.866.30.1.35.5.5.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

vcvSnmpManagerStatus 2.1.866.30.1.35.5.5.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcvSnmpManagerName 2.1.866.30.1.35.5.5.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..12)  

vcvSnmpManagerSendTraps 2.1.866.30.1.35.5.5.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

vcvSnmpManagerTrapsUdpPort 2.1.866.30.1.35.5.5.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

vcvRemoteConfTable 2.1.866.30.1.35.5.5.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvRemoteConfEntry

vcvRemoteConfEntry 2.1.866.30.1.35.5.5.3.1
An entry of vcvRemoteConfTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvRemoteConfEntry  

vcvRemoteConfName 2.1.866.30.1.35.5.5.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..12)  

vcvRemoteConfStatus 2.1.866.30.1.35.5.5.3.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcvRemoteConfWanAddress 2.1.866.30.1.35.5.5.3.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

vcvTftpTable 2.1.866.30.1.35.5.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvTftpEntry

vcvTftpEntry 2.1.866.30.1.35.5.10.1
An entry of vcvTftpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvTftpEntry  

vcvTftpIpAddress 2.1.866.30.1.35.5.10.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

vcvTftpStatus 2.1.866.30.1.35.5.10.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcvTftpName 2.1.866.30.1.35.5.10.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..32)  

vcvTftpRetryTimer 2.1.866.30.1.35.5.10.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..600  

vcvTftpInactTimer 2.1.866.30.1.35.5.10.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..3600  

vcvRemoteNetToMediaTable 2.1.866.30.1.35.5.15
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvRemoteNetToMediaEntry

vcvRemoteNetToMediaEntry 2.1.866.30.1.35.5.15.1
An entry of vcvRemoteNetToMediaTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvRemoteNetToMediaEntry  

vcvRemNetIpAddress 2.1.866.30.1.35.5.15.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

vcvRemNetStatus 2.1.866.30.1.35.5.15.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcvRemNetWanAddress 2.1.866.30.1.35.5.15.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

vcvRemNetEncapsulation 2.1.866.30.1.35.5.15.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fripSimple(1), fripRFC(2)  

vcvVoiceVirtualPort 2.1.866.30.1.35.10
OBJECT IDENTIFIER    

vcvVoiceGen 2.1.866.30.1.35.10.1
OBJECT IDENTIFIER    

vcvVoiceVirtualPortId 2.1.866.30.1.35.10.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER vpVoix(1), vpIp(2)  

vcvVoiceTransportTable 2.1.866.30.1.35.10.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvVoiceTransportEntry

vcvVoiceTransportEntry 2.1.866.30.1.35.10.2.1
An entry of vcvVoiceTransportTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvVoiceTransportEntry  

vcvVoiceTransProfileId 2.1.866.30.1.35.10.2.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

vcvVoiceTransEncapsulationMode 2.1.866.30.1.35.10.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER frf(1), private(2)  

vcvVoiceTransMaxPayLoadNumber 2.1.866.30.1.35.10.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

vcvVoiceTransCompressionAlgorithm 2.1.866.30.1.35.10.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER g728(1), celp(2), g729(3), g729A(4)  

vcvVoiceTransJitterCompensation 2.1.866.30.1.35.10.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..9  

vcvVoiceTransVoicePacketsCombination 2.1.866.30.1.35.10.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

vcvVoiceTransQosBc 2.1.866.30.1.35.10.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s9600(1), s14400(2), s19200(3), s32000(4), s38400(5), s48000(6)  

vcvVoiceTransQosBe 2.1.866.30.1.35.10.2.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s9600(1), s14400(2), s19200(3), s32000(4), s38400(5), s48000(6)  

vcvVoiceTransQosCir 2.1.866.30.1.35.10.2.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s9600(1), s14400(2), s19200(3), s32000(4), s38400(5), s48000(6)  

vcvVoiceSuscriberTable 2.1.866.30.1.35.10.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvVoiceSuscriberEntry

vcvVoiceSuscriberEntry 2.1.866.30.1.35.10.3.1
An entry of vcvVoiceSuscriberTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvVoiceSuscriberEntry  

vcvVoiceSuscrOrderNumber 2.1.866.30.1.35.10.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..9  

vcvVoiceSuscrNumber 2.1.866.30.1.35.10.3.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..21)  

vcvVoiceSuscrStatus 2.1.866.30.1.35.10.3.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcvVoiceSuscrTransportNetwork 2.1.866.30.1.35.10.3.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fr(1), other(2)  

vcvVoiceSuscrTransportNetworkAddress 2.1.866.30.1.35.10.3.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

vcvVoiceSuscrTransportProfileId 2.1.866.30.1.35.10.3.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

vcvVoiceSuscrRemovedDigitNumber 2.1.866.30.1.35.10.3.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..21  

vcvVoiceSuscrInsPrefix 2.1.866.30.1.35.10.3.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

vcvVoiceSuscrInsSuffix 2.1.866.30.1.35.10.3.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

vcvVoiceSwTable 2.1.866.30.1.35.10.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvVoiceSwEntry

vcvVoiceSwEntry 2.1.866.30.1.35.10.4.1
An entry of vcvVoiceSwTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvVoiceSwEntry  

vcvVoiceSwOrderNumber 2.1.866.30.1.35.10.4.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..9  

vcvVoiceSwSuscriberNumber 2.1.866.30.1.35.10.4.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..21)  

vcvVoiceSwStatus 2.1.866.30.1.35.10.4.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcvVoiceSwLogPortSetId 2.1.866.30.1.35.10.4.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9  

vcvVoiceSwRemovedDigitNumber 2.1.866.30.1.35.10.4.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..21  

vcvVoiceSwInsPrefix 2.1.866.30.1.35.10.4.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

vcvVoiceSwInsSuffix 2.1.866.30.1.35.10.4.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

vcvDialingReceptTable 2.1.866.30.1.35.10.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvDialingReceptEntry

vcvDialingReceptEntry 2.1.866.30.1.35.10.5.1
An entry of vcvDialingReceptTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvDialingReceptEntry  

vcvDialRxSuscriberNumber 2.1.866.30.1.35.10.5.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..21)  

vcvDialRxStatus 2.1.866.30.1.35.10.5.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcvDialRxNumberLength 2.1.866.30.1.35.10.5.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..21  

vcvDialRxEndOfDialingTimer 2.1.866.30.1.35.10.5.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcvVoiceLogPort 2.1.866.30.1.35.10.10
OBJECT IDENTIFIER    

vcvVoiceLogicalPortTable 2.1.866.30.1.35.10.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvVoiceLogicalPortEntry

vcvVoiceLogicalPortEntry 2.1.866.30.1.35.10.10.1.1
An entry of vcvVoiceLogicalPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvVoiceLogicalPortEntry  

vcvVoiceLogPortId 2.1.866.30.1.35.10.10.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vcvVoiceLogPortStatus 2.1.866.30.1.35.10.10.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

vcvVoiceLogPortType 2.1.866.30.1.35.10.10.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER emPermanent(1), emSwitched(2), fxx(3)  

vcvProfileTone 2.1.866.30.1.35.10.10.5
OBJECT IDENTIFIER    

vcvToneGenTable 2.1.866.30.1.35.10.10.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvToneGenEntry

vcvToneGenEntry 2.1.866.30.1.35.10.10.5.1.1
An entry of vcvToneGenTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvToneGenEntry  

vcvToneGenProfileId 2.1.866.30.1.35.10.10.5.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vcvToneGenLevel 2.1.866.30.1.35.10.10.5.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..60  

vcvToneTable 2.1.866.30.1.35.10.10.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvToneEntry

vcvToneEntry 2.1.866.30.1.35.10.10.5.2.1
An entry of vcvToneTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvToneEntry  

vcvToneProfileId 2.1.866.30.1.35.10.10.5.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vcvToneType 2.1.866.30.1.35.10.10.5.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dialTone(1), trouble(2), congestion(3), busy(4), callBack(5)  

vcvToneEnable 2.1.866.30.1.35.10.10.5.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

vcvToneFreq1 2.1.866.30.1.35.10.10.5.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

vcvToneDuration1 2.1.866.30.1.35.10.10.5.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..500  

vcvToneFreq2 2.1.866.30.1.35.10.10.5.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

vcvToneDuration2 2.1.866.30.1.35.10.10.5.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..500  

vcvVoiceLogicalPortEM 2.1.866.30.1.35.10.10.10
OBJECT IDENTIFIER    

vcvEMPerm 2.1.866.30.1.35.10.10.10.1
OBJECT IDENTIFIER    

vcvEMPermTable 2.1.866.30.1.35.10.10.10.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvEMPermEntry

vcvEMPermEntry 2.1.866.30.1.35.10.10.10.1.1.1
An entry of vcvEMPermTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvEMPermEntry  

vcvEMPermLpId 2.1.866.30.1.35.10.10.10.1.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vcvEMPermCommunicationMode 2.1.866.30.1.35.10.10.10.1.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2)  

vcvEMPermRemoteNumber 2.1.866.30.1.35.10.10.10.1.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

vcvEMPermInterfaceId 2.1.866.30.1.35.10.10.10.1.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v0(1), v1(2)  

vcvEMSw 2.1.866.30.1.35.10.10.10.2
OBJECT IDENTIFIER    

vcvEMSwTable 2.1.866.30.1.35.10.10.10.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvEMSwEntry

vcvEMSwEntry 2.1.866.30.1.35.10.10.10.2.1.1
An entry of vcvEMSwTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvEMSwEntry  

vcvEMSwLpId 2.1.866.30.1.35.10.10.10.2.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vcvEMSwLogPortSetId 2.1.866.30.1.35.10.10.10.2.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9  

vcvEMSwCallType 2.1.866.30.1.35.10.10.10.2.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER incoming(1), outgoing(2), mixed(3)  

vcvEMSwRemoteNumber 2.1.866.30.1.35.10.10.10.2.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

vcvEMSwConfigId 2.1.866.30.1.35.10.10.10.2.1.1.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vcvEMSwInterfaceId 2.1.866.30.1.35.10.10.10.2.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v0(1), v1(2)  

vcvEMConfigTable 2.1.866.30.1.35.10.10.10.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvEMConfigEntry

vcvEMConfigEntry 2.1.866.30.1.35.10.10.10.2.2.1
An entry of vcvEMConfigTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvEMConfigEntry  

vcvEMConfId 2.1.866.30.1.35.10.10.10.2.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vcvEMConfCallSignalling 2.1.866.30.1.35.10.10.10.2.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nColisee(1), uColisee(2), simm(3), sDelay(4), swink(5), noResp(6)  

vcvEMConfDialingMode 2.1.866.30.1.35.10.10.10.2.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dec(1), dtmf(2)  

vcvEMConfDialingTimeOut 2.1.866.30.1.35.10.10.10.2.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

vcvEMConfSigChannelDiscTimeOut 2.1.866.30.1.35.10.10.10.2.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

vcvEMConfTimeBetweenSuccOutCall 2.1.866.30.1.35.10.10.10.2.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

vcvEMConfLineInterfacePolarity 2.1.866.30.1.35.10.10.10.2.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), inverted(2)  

vcvEMConfMinLineSeizureAckTime 2.1.866.30.1.35.10.10.10.2.2.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..50  

vcvEMConfMaxLineSeizureAckTime 2.1.866.30.1.35.10.10.10.2.2.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..50  

vcvEMConfLineSeizureAckTime 2.1.866.30.1.35.10.10.10.2.2.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..50  

vcvEMConfClearToIncCallTime 2.1.866.30.1.35.10.10.10.2.2.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 3..50  

vcvEMConfSeizureAckPulseDuration 2.1.866.30.1.35.10.10.10.2.2.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

vcvEMConfMinSeizureAckPulseDuration 2.1.866.30.1.35.10.10.10.2.2.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

vcvEMConfDialingFormat 2.1.866.30.1.35.10.10.10.2.2.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ds1(1), ds2(2)  

vcvEMConfInterdigitTime 2.1.866.30.1.35.10.10.10.2.2.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

vcvEMConfPauseTime 2.1.866.30.1.35.10.10.10.2.2.1.16
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

vcvEMConfDtmfDigitTime 2.1.866.30.1.35.10.10.10.2.2.1.17
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..10  

vcvEMConfDtmfDigitLevel 2.1.866.30.1.35.10.10.10.2.2.1.18
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..40  

vcvEMConfDelayBeforeDialing 2.1.866.30.1.35.10.10.10.2.2.1.19
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

vcvEMConfDigitReceptionTimeOut 2.1.866.30.1.35.10.10.10.2.2.1.20
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

vcvEMConfEndOfDialingTimer 2.1.866.30.1.35.10.10.10.2.2.1.21
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..60  

vcvEMConfToneProfile 2.1.866.30.1.35.10.10.10.2.2.1.22
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vcvVoiceLogicalPortFxx 2.1.866.30.1.35.10.10.15
OBJECT IDENTIFIER    

vcvFxxLpTable 2.1.866.30.1.35.10.10.15.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvFxxLpEntry

vcvFxxLpEntry 2.1.866.30.1.35.10.10.15.1.1
An entry of vcvFxxLpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvFxxLpEntry  

vcvFxxLpLogPortId 2.1.866.30.1.35.10.10.15.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vcvFxxLpSetId 2.1.866.30.1.35.10.10.15.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9  

vcvFxxLpCallType 2.1.866.30.1.35.10.10.15.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER incoming(1), outgoing(2), mixed(3)  

vcvFxxLpRemoteNumber 2.1.866.30.1.35.10.10.15.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

vcvFxxLpConfigId 2.1.866.30.1.35.10.10.15.1.1.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vcvFxxLpInterfaceId 2.1.866.30.1.35.10.10.15.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v0(1), v1(2)  

vcvFxxConfigTable 2.1.866.30.1.35.10.10.15.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvFxxConfigEntry

vcvFxxConfigEntry 2.1.866.30.1.35.10.10.15.2.1
An entry of vcvFxxConfigTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvFxxConfigEntry  

vcvFxxConfId 2.1.866.30.1.35.10.10.15.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vcvFxxConfCallSignalling 2.1.866.30.1.35.10.10.15.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fxx(1), other(2)  

vcvFxxConfDialingMode 2.1.866.30.1.35.10.10.15.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dec(1), dtmf(2)  

vcvFxxConfSigChannelDiscTimeOut 2.1.866.30.1.35.10.10.15.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

vcvFxxConfTimeBetweenSuccOutCall 2.1.866.30.1.35.10.10.15.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

vcvFxxConfDialingFormat 2.1.866.30.1.35.10.10.15.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ds1(1), ds2(2)  

vcvFxxConfInterdigitTime 2.1.866.30.1.35.10.10.15.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

vcvFxxConfPauseTime 2.1.866.30.1.35.10.10.15.2.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

vcvFxxConfDtmfDigitTime 2.1.866.30.1.35.10.10.15.2.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..10  

vcvFxxConfDtmfDigitLevel 2.1.866.30.1.35.10.10.15.2.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..40  

vcvFxxConfTxRecallSignalDuration 2.1.866.30.1.35.10.10.15.2.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..50  

vcvFxxConfDelayBeforeDialing 2.1.866.30.1.35.10.10.15.2.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..50  

vcvFxxConfDialingTimeOut 2.1.866.30.1.35.10.10.15.2.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

vcvFxxConfDigitReceptionTimeOut 2.1.866.30.1.35.10.10.15.2.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

vcvFxxConfEndOfDialingTimer 2.1.866.30.1.35.10.10.15.2.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..60  

vcvFxxConfMinRxRecallSignalDuration 2.1.866.30.1.35.10.10.15.2.1.16
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..25  

vcvFxxConfToneProfile 2.1.866.30.1.35.10.10.15.2.1.17
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vcvFxxConfRingingProfile 2.1.866.30.1.35.10.10.15.2.1.18
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vcvFxxRingTable 2.1.866.30.1.35.10.10.15.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvFxxRingEntry

vcvFxxRingEntry 2.1.866.30.1.35.10.10.15.3.1
An entry of vcvFxxRingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvFxxRingEntry  

vcvFxxRingProfile 2.1.866.30.1.35.10.10.15.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

vcvFxxRingFrequency 2.1.866.30.1.35.10.10.15.3.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..80  

vcvFxxRingTopDuration 2.1.866.30.1.35.10.10.15.3.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..50  

vcvFxxRingSilenceDuration 2.1.866.30.1.35.10.10.15.3.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..50  

vcvFxxRingMaxRingingTime 2.1.866.30.1.35.10.10.15.3.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..600  

vcvAnalogLines 2.1.866.30.1.35.10.15
OBJECT IDENTIFIER    

vcvAnalogLineTable 2.1.866.30.1.35.10.15.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvAnalogLineEntry

vcvAnalogLineEntry 2.1.866.30.1.35.10.15.1.1
An entry of vcvAnalogLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvAnalogLineEntry  

vcvAnalogLineInterfaceId 2.1.866.30.1.35.10.15.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v0(1), v1(2)  

vcvAnalogLineTypeInterface 2.1.866.30.1.35.10.15.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER em(1), fxo(2), fxs(3), ibx(4), ia50Hz(5)  

vcvAnalogLineVoiceProfile 2.1.866.30.1.35.10.15.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

vcvVoiceProfileTable 2.1.866.30.1.35.10.15.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvVoiceProfileEntry

vcvVoiceProfileEntry 2.1.866.30.1.35.10.15.5.1
An entry of vcvVoiceProfileTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvVoiceProfileEntry  

vcvVoiceProfId 2.1.866.30.1.35.10.15.5.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

vcvVoiceProfTransmitLevel 2.1.866.30.1.35.10.15.5.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..24  

vcvVoiceProfReceiveLevel 2.1.866.30.1.35.10.15.5.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

vcvVoiceProfSilenceDetection 2.1.866.30.1.35.10.15.5.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2), cng(3)  

vcvVoiceProfSilenceDetectionLevel 2.1.866.30.1.35.10.15.5.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER low(1), medium(2), high(3)  

vcvVoiceProfEchoCancellation 2.1.866.30.1.35.10.15.5.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

vcvVoiceProfEchoCancellationLength 2.1.866.30.1.35.10.15.5.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER low(1), medium(2), high(3)  

vcvVoiceProfNoiseFramesPeriodicity 2.1.866.30.1.35.10.15.5.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..10  

vcvVoiceProfLoopActivation 2.1.866.30.1.35.10.15.5.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), local(2), remote(3)  

vcvVoiceProfFaxActivation 2.1.866.30.1.35.10.15.5.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

vcvVoiceProfMaximumFaxSpeed 2.1.866.30.1.35.10.15.5.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s9600(1), s4800(2)  

vcvVoicePhysicalPortTable 2.1.866.30.1.35.10.15.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcvVoicePhysicalPortEntry

vcvVoicePhysicalPortEntry 2.1.866.30.1.35.10.15.10.1
An entry of vcvVoicePhysicalPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcvVoicePhysicalPortEntry  

vcvVoicePhysPortId 2.1.866.30.1.35.10.15.10.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v0(1), v1(2)  

vcvVoicePhysPortConnector 2.1.866.30.1.35.10.15.10.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER em(1), fxofxs(2), fxo(3), fxs(4), ia50(5)  

dcControl 2.1.866.30.20.1
OBJECT IDENTIFIER    

dcCtlDate 2.1.866.30.20.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

dcCtlHour 2.1.866.30.20.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

dcCtlConfigCom 2.1.866.30.20.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), check(2), load(5), save(6), hotReset(10)  

dcCtlConfigLoad 2.1.866.30.20.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..9  

dcCtlErrorTable 2.1.866.30.20.1.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcCtlErrorEntry

dcCtlErrorEntry 2.1.866.30.20.1.10.1
An entry of dcCtlErrorTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcCtlErrorEntry  

dcCtlErrorIndex 2.1.866.30.20.1.10.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

dcCtlErrorCode 2.1.866.30.20.1.10.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

dcCtlErrorMessage 2.1.866.30.20.1.10.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dcCtlErrorTime 2.1.866.30.20.1.10.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

dcSystem 2.1.866.30.20.5
OBJECT IDENTIFIER    

dcSysConfActive 2.1.866.30.20.5.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s1(1), s2(2), s3(3), s4(4), s5(5), s6(6), s7(7), s8(8), s9(9), w0(10), w1(11), w2(12), w3(13), w4(14), w5(15), w6(16), w7(17), w8(18), w9(19), w0-1(20), w0-2(21), w0-3(22), w0-4(23), w0-5(24), w0-6(25), w0-7(26), w0-8(27), w0-9(28)  

dcSysConfDate 2.1.866.30.20.5.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

dcSysConfHour 2.1.866.30.20.5.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

dcManagement 2.1.866.30.20.10
OBJECT IDENTIFIER    

dcmAlrmGenTable 2.1.866.30.20.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcmAlrmGenEntry

dcmAlrmGenEntry 2.1.866.30.20.10.1.1
An entry of dcmAlrmGenTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcmAlrmGenEntry  

dcmAlrmGenFamilyId 2.1.866.30.20.10.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9), f09Synchronization(10)  

dcmAlrmGenTyp 2.1.866.30.20.10.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER lnkReady208(1), lnkNotReady209(2), fatalError222(3), reboot233(4), dspOutofOrder257(5), dspNoResourcesLeft258(6)  

dcmAlrmGenTrapSend 2.1.866.30.20.10.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmGenDisplay 2.1.866.30.20.10.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmSCTable 2.1.866.30.20.10.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcmAlrmSCEntry

dcmAlrmSCEntry 2.1.866.30.20.10.2.1
An entry of dcmAlrmSCTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcmAlrmSCEntry  

dcmAlrmSCFamilyId 2.1.866.30.20.10.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9), f09Synchronization(10)  

dcmAlrmSCTyp 2.1.866.30.20.10.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER scReady210(1), scNotReady211(2), frAddrError223(3), dlciError224(4), scNotFree225(5), scDynamic226(6), scReinit227(7), unexpectedFrame230(8)  

dcmAlrmSCTrapSend 2.1.866.30.20.10.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmSCDisplay 2.1.866.30.20.10.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmVCTable 2.1.866.30.20.10.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcmAlrmVCEntry

dcmAlrmVCEntry 2.1.866.30.20.10.3.1
An entry of dcmAlrmVCTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcmAlrmVCEntry  

dcmAlrmVCFamilyId 2.1.866.30.20.10.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9), f09Synchronization(10)  

dcmAlrmVCTyp 2.1.866.30.20.10.3.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vcReady212(1), vcNotReady213(2), lossOfSync220(3), syncBack221(4), vcRejected231(5), endOfReject232(6)  

dcmAlrmVCTrapSend 2.1.866.30.20.10.3.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmVCDisplay 2.1.866.30.20.10.3.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmLMITable 2.1.866.30.20.10.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcmAlrmLMIEntry

dcmAlrmLMIEntry 2.1.866.30.20.10.4.1
An entry of dcmAlrmLMITable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcmAlrmLMIEntry  

dcmAlrmLMIFamilyId 2.1.866.30.20.10.4.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9), f09Synchronization(10)  

dcmAlrmLMITyp 2.1.866.30.20.10.4.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dcnxLmi234(1), cnxLmi235(2), lmiDlciNotConf236(3), lmiIntError237(4)  

dcmAlrmLMITrapSend 2.1.866.30.20.10.4.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmLMIDisplay 2.1.866.30.20.10.4.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmSwTable 2.1.866.30.20.10.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcmAlrmSwEntry

dcmAlrmSwEntry 2.1.866.30.20.10.5.1
An entry of dcmAlrmSwTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcmAlrmSwEntry  

dcmAlrmSwFamilyId 2.1.866.30.20.10.5.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9), f09Synchronization(10)  

dcmAlrmSwTyp 2.1.866.30.20.10.5.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER outgoingCall238(1), incomingCall239(2), localDisc240(3), remoteDisc241(4), backup242(5)  

dcmAlrmSwTrapSend 2.1.866.30.20.10.5.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmSwDisplay 2.1.866.30.20.10.5.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmCmpTable 2.1.866.30.20.10.6
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcmAlrmCmpEntry

dcmAlrmCmpEntry 2.1.866.30.20.10.6.1
An entry of dcmAlrmCmpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcmAlrmCmpEntry  

dcmAlrmCmpFamilyId 2.1.866.30.20.10.6.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9), f09Synchronization(10)  

dcmAlrmCmpTyp 2.1.866.30.20.10.6.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER compOn214(1), compOff215(2), algoCompNotOk228(3), algoCompOk229(4)  

dcmAlrmCmpTrapSend 2.1.866.30.20.10.6.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmCmpDisplay 2.1.866.30.20.10.6.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmFaxTable 2.1.866.30.20.10.7
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcmAlrmFaxEntry

dcmAlrmFaxEntry 2.1.866.30.20.10.7.1
An entry of dcmAlrmFaxTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcmAlrmFaxEntry  

dcmAlrmFaxFamilyId 2.1.866.30.20.10.7.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9), f09Synchronization(10)  

dcmAlrmFaxTyp 2.1.866.30.20.10.7.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER faxStart218(1), faxEnd219(2)  

dcmAlrmFaxTrapSend 2.1.866.30.20.10.7.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmFaxDisplay 2.1.866.30.20.10.7.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmTftpTable 2.1.866.30.20.10.8
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcmAlrmTftpEntry

dcmAlrmTftpEntry 2.1.866.30.20.10.8.1
An entry of dcmAlrmTftpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcmAlrmTftpEntry  

dcmAlrmTftpFamilyId 2.1.866.30.20.10.8.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9), f09Synchronization(10)  

dcmAlrmTftpTyp 2.1.866.30.20.10.8.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dwnStart243(1), dwnEnd244(2), dwnError245(3)  

dcmAlrmTftpTrapSend 2.1.866.30.20.10.8.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmTftpDisplay 2.1.866.30.20.10.8.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmSvcTable 2.1.866.30.20.10.9
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcmAlrmSvcEntry

dcmAlrmSvcEntry 2.1.866.30.20.10.9.1
An entry of dcmAlrmSvcTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcmAlrmSvcEntry  

dcmAlrmSvcFamilyId 2.1.866.30.20.10.9.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9), f09Synchronization(10)  

dcmAlrmSvcTyp 2.1.866.30.20.10.9.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER svcOutCall246(1), svcInCall247(2), svcLocalConnect248(3), svcLocalDisc249(4), svcRemoteDisc250(5), svcOutFailCall251(6), svcInFailCall252(7)  

dcmAlrmSvcTrapSend 2.1.866.30.20.10.9.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmSvcDisplay 2.1.866.30.20.10.9.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmSyncTable 2.1.866.30.20.10.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcmAlrmSyncEntry

dcmAlrmSyncEntry 2.1.866.30.20.10.10.1
An entry of dcmAlrmSyncTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcmAlrmSyncEntry  

dcmAlrmSyncFamilyId 2.1.866.30.20.10.10.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f00System(1), f01Tftp(2), f02Junction(3), f03Lmi(4), f04Svc(5), f05Compression(6), f06ServiceCanal(7), f07Fax(8), f08Switching(9), f09Synchronization(10)  

dcmAlrmSyncTyp 2.1.866.30.20.10.10.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tdmUp253(1), tdmDown254(2), vpbSync255(3), vpbOutofSync256(4)  

dcmAlrmSyncTrapSend 2.1.866.30.20.10.10.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcmAlrmSyncDisplay 2.1.866.30.20.10.10.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcInterfaces 2.1.866.30.20.15
OBJECT IDENTIFIER    

dcfPhysicalPortTable 2.1.866.30.20.15.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcfPhysicalPortEntry

dcfPhysicalPortEntry 2.1.866.30.20.15.1.1
An entry of dcfPhysicalPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcfPhysicalPortEntry  

dcfPhysPortId 2.1.866.30.20.15.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER l0(1), l1(2), frontPannel(3)  

dcfPhysPortConnector 2.1.866.30.20.15.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER db25(1), din(2)  

dcfNumericLines 2.1.866.30.20.15.5
OBJECT IDENTIFIER    

dcfNumericLineTable 2.1.866.30.20.15.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcfNumericLineEntry

dcfNumericLineEntry 2.1.866.30.20.15.5.1.1
An entry of dcfNumericLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcfNumericLineEntry  

dcfNumericLineInterfaceId 2.1.866.30.20.15.5.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER l0(1), l1(2), frontPannel(3)  

dcfNumericLineType 2.1.866.30.20.15.5.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dataLine(1), configurationLine(2), debug(3)  

dcfDataLineTable 2.1.866.30.20.15.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcfDataLineEntry

dcfDataLineEntry 2.1.866.30.20.15.5.2.1
An entry of dcfDataLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcfDataLineEntry  

dcfDataLineInterfaceId 2.1.866.30.20.15.5.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER l0(1), l1(2), other(3)  

dcfDataLineRate 2.1.866.30.20.15.5.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s4800(1), s9600(2), s19200(3), s38400(4), s48000(5), s56000(6), s64000(7), s72000(8), s128000(9), s144000(10), s256000(11), s512000(12), s1024000(13), s2048000(14)  

dcfDataLineRts105 2.1.866.30.20.15.5.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), used(2), standard(3), off(4), on(5)  

dcfDataLineDtr108 2.1.866.30.20.15.5.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), used(2), standard(3), off(4), on(5)  

dcfDataLineCts106 2.1.866.30.20.15.5.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), used(2), standard(3), off(4), on(5)  

dcfDataLineDsr107 2.1.866.30.20.15.5.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), used(2), standard(3), off(4), on(5)  

dcfDataLineDcd109 2.1.866.30.20.15.5.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), used(2), standard(3), off(4), on(5)  

dcfConfLineTable 2.1.866.30.20.15.5.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcfConfLineEntry

dcfConfLineEntry 2.1.866.30.20.15.5.3.1
An entry of dcfConfLineTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcfConfLineEntry  

dcfConfLineInterfaceId 2.1.866.30.20.15.5.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER l0(1), l1(2), frontPannel(3)  

dcfConfLineRate 2.1.866.30.20.15.5.3.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER s4800(1), s9600(2), s19200(3), s38400(4), s48000(5), s56000(6), s64000(7), s72000(8), s128000(9), s144000(10), s256000(11), s512000(12), s1024000(13), s2048000(14)  

dcLogicalPorts 2.1.866.30.20.20
OBJECT IDENTIFIER    

dclLogicalPortTable 2.1.866.30.20.20.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DclLogicalPortEntry

dclLogicalPortEntry 2.1.866.30.20.20.1.1
An entry of dclLogicalPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DclLogicalPortEntry  

dclLogPortId 2.1.866.30.20.20.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dclLogPortStatus 2.1.866.30.20.20.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dclLogPortType 2.1.866.30.20.20.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER frTe(1), frSe(2)  

dclFrameRelay 2.1.866.30.20.20.5
OBJECT IDENTIFIER    

dclFrTerminalEquipment 2.1.866.30.20.20.5.1
OBJECT IDENTIFIER    

dclFrTeLogPortTable 2.1.866.30.20.20.5.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DclFrTeLogPortEntry

dclFrTeLogPortEntry 2.1.866.30.20.20.5.1.1.1
An entry of dclFrTeLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DclFrTeLogPortEntry  

dclFrTeLpLogPortId 2.1.866.30.20.20.5.1.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dclFrTeLpInterfaceId 2.1.866.30.20.20.5.1.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER l0(1), l1(2), other(3)  

dclFrTeLpConfigId 2.1.866.30.20.20.5.1.1.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dclFrTeLpLmi 2.1.866.30.20.20.5.1.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), lmiUni(2)  

dclFrSwitchEquipment 2.1.866.30.20.20.5.2
OBJECT IDENTIFIER    

dclFrSeLogPortTable 2.1.866.30.20.20.5.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DclFrSeLogPortEntry

dclFrSeLogPortEntry 2.1.866.30.20.20.5.2.1.1
An entry of dclFrSeLogPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DclFrSeLogPortEntry  

dclFrSeLpLogPortId 2.1.866.30.20.20.5.2.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dclFrSeLpInterfaceId 2.1.866.30.20.20.5.2.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER l0(1), l1(2), other(3)  

dclFrSeLpConfigId 2.1.866.30.20.20.5.2.1.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dclFrConfigurationTe 2.1.866.30.20.20.5.3
OBJECT IDENTIFIER    

dclFrLmiParameterTable 2.1.866.30.20.20.5.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DclFrLmiParameterEntry

dclFrLmiParameterEntry 2.1.866.30.20.20.5.3.1.1
An entry of dclFrLmiParameterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DclFrLmiParameterEntry  

dclFrLmiParaConfigId 2.1.866.30.20.20.5.3.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dclFrLmiParaDlci 2.1.866.30.20.20.5.3.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1023  

dclFrLmiParaStandard 2.1.866.30.20.20.5.3.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ansiT1-617d(1), itutQ933a(2)  

dclFrLmiParaAccessibilityCondition 2.1.866.30.20.20.5.3.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..10  

dclFrLmiParaN391FullStatusPollCount 2.1.866.30.20.20.5.3.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

dclFrLmiParaN392ErrorThreshold 2.1.866.30.20.20.5.3.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

dclFrLmiParaN393MonitoredEventCount 2.1.866.30.20.20.5.3.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

dclFrLmiParaT391LinkIntegPollTimer 2.1.866.30.20.20.5.3.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

dclFrConfigurationSe 2.1.866.30.20.20.5.4
OBJECT IDENTIFIER    

dclFrSeSignallingTable 2.1.866.30.20.20.5.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DclFrSeSignallingEntry

dclFrSeSignallingEntry 2.1.866.30.20.20.5.4.1.1
An entry of dclFrSeSignallingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DclFrSeSignallingEntry  

dclFrSeSigConfigId 2.1.866.30.20.20.5.4.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dclFrSeSigOuputTimeout 2.1.866.30.20.20.5.4.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..51000  

dclFrSeSigSignalOutputWinSize 2.1.866.30.20.20.5.4.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

dclFrSeSigN200RetransMaxCount 2.1.866.30.20.20.5.4.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

dclFrSeSigT200RetransTimer 2.1.866.30.20.20.5.4.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..25500  

dclFrSeSigT203InactivityTimer 2.1.866.30.20.20.5.4.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

dclFrSeSigT303SetupResponseTimer 2.1.866.30.20.20.5.4.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

dclFrSeSigT305DisconnectResponseTimer 2.1.866.30.20.20.5.4.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

dclFrSeSigT308ReleaseResponseTimer 2.1.866.30.20.20.5.4.1.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

dclFrSeSigT310CallProceedingTimer 2.1.866.30.20.20.5.4.1.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

dclFrSeSigT316RestartAcknowledgeTimer 2.1.866.30.20.20.5.4.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

dcWanSwitch 2.1.866.30.20.25
OBJECT IDENTIFIER    

dcwEquipParams 2.1.866.30.20.25.1
OBJECT IDENTIFIER    

dcwEquipDnicZoAddr 2.1.866.30.20.25.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

dcwEquipVoiceRoutingServicePortAddr 2.1.866.30.20.25.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

dcwEquipIpVirtualPortAddr 2.1.866.30.20.25.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

dcwEquipRemoteConfPortAddr 2.1.866.30.20.25.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

dcwEquipVoiceVirtualPortAddr 2.1.866.30.20.25.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

dcwEquipSVCDisconnectOnCongestion 2.1.866.30.20.25.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dcwABPvcLpTable 2.1.866.30.20.25.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcwABPvcLpEntry

dcwABPvcLpEntry 2.1.866.30.20.25.2.1
An entry of dcwABPvcLpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcwABPvcLpEntry  

dcwABPvcLpId 2.1.866.30.20.25.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dcwABPvcLpAddress 2.1.866.30.20.25.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

dcVirtualPorts 2.1.866.30.20.30
OBJECT IDENTIFIER    

dcvVirtualPortTable 2.1.866.30.20.30.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvVirtualPortEntry

dcvVirtualPortEntry 2.1.866.30.20.30.1.1
An entry of dcvVirtualPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvVirtualPortEntry  

dcvVirtualPortId 2.1.866.30.20.30.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vpVoix(1), vpIp(2)  

dcvIpVirtualPort 2.1.866.30.20.30.5
OBJECT IDENTIFIER    

dcvIpLocalTable 2.1.866.30.20.30.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvIpLocalEntry

dcvIpLocalEntry 2.1.866.30.20.30.5.1.1
An entry of dcvIpLocalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvIpLocalEntry  

dcvIpLocVirtualPortId 2.1.866.30.20.30.5.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vpVoix(1), vpIp(2)  

dcvIpLocAddressHost 2.1.866.30.20.30.5.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dcvIpLocSubNetMask 2.1.866.30.20.30.5.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dcvIpLocMtu 2.1.866.30.20.30.5.1.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 576..9180  

dcvIpLocRouteNextHop 2.1.866.30.20.30.5.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dcvIpLocMinimumRecallTimer 2.1.866.30.20.30.5.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

dcvIpLocSvcClearCallTimer 2.1.866.30.20.30.5.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

dcvIpLocSvcCallRetryCount 2.1.866.30.20.30.5.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

dcvSnmp 2.1.866.30.20.30.5.5
OBJECT IDENTIFIER    

dcvSnmpGen 2.1.866.30.20.30.5.5.1
OBJECT IDENTIFIER    

dcvSnmpGenVirtualPortId 2.1.866.30.20.30.5.5.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER vpVoix(1), vpIp(2)  

dcvSnmpGenCommunityStringReadOnly 2.1.866.30.20.30.5.5.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..14)  

dcvSnmpGenCommunityStringReadWrite 2.1.866.30.20.30.5.5.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..14)  

dcvSnmpGenCommunityStringTrap 2.1.866.30.20.30.5.5.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..14)  

dcvSnmpGenAuthenticationFailureTrap 2.1.866.30.20.30.5.5.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dcvSnmpManagerTable 2.1.866.30.20.30.5.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvSnmpManagerEntry

dcvSnmpManagerEntry 2.1.866.30.20.30.5.5.2.1
An entry of dcvSnmpManagerTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvSnmpManagerEntry  

dcvSnmpManagerIpAddress 2.1.866.30.20.30.5.5.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

dcvSnmpManagerStatus 2.1.866.30.20.30.5.5.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dcvSnmpManagerName 2.1.866.30.20.30.5.5.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..12)  

dcvSnmpManagerSendTraps 2.1.866.30.20.30.5.5.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dcvSnmpManagerTrapsUdpPort 2.1.866.30.20.30.5.5.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

dcvRemoteConfTable 2.1.866.30.20.30.5.5.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvRemoteConfEntry

dcvRemoteConfEntry 2.1.866.30.20.30.5.5.3.1
An entry of dcvRemoteConfTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvRemoteConfEntry  

dcvRemoteConfName 2.1.866.30.20.30.5.5.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..12)  

dcvRemoteConfStatus 2.1.866.30.20.30.5.5.3.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dcvRemoteConfWanAddress 2.1.866.30.20.30.5.5.3.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

dcvTftpTable 2.1.866.30.20.30.5.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvTftpEntry

dcvTftpEntry 2.1.866.30.20.30.5.10.1
An entry of dcvTftpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvTftpEntry  

dcvTftpIpAddress 2.1.866.30.20.30.5.10.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

dcvTftpStatus 2.1.866.30.20.30.5.10.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dcvTftpName 2.1.866.30.20.30.5.10.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..32)  

dcvTftpRetryTimer 2.1.866.30.20.30.5.10.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..600  

dcvTftpInactTimer 2.1.866.30.20.30.5.10.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..3600  

dcvRemoteNetToMediaTable 2.1.866.30.20.30.5.15
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvRemoteNetToMediaEntry

dcvRemoteNetToMediaEntry 2.1.866.30.20.30.5.15.1
An entry of dcvRemoteNetToMediaTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvRemoteNetToMediaEntry  

dcvRemNetIpAddress 2.1.866.30.20.30.5.15.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

dcvRemNetStatus 2.1.866.30.20.30.5.15.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dcvRemNetWanAddress 2.1.866.30.20.30.5.15.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

dcvRemNetEncapsulation 2.1.866.30.20.30.5.15.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fripSimple(1), fripRFC(2)  

dcvVoiceVirtualPort 2.1.866.30.20.30.10
OBJECT IDENTIFIER    

dcvVoiceGen 2.1.866.30.20.30.10.1
OBJECT IDENTIFIER    

dcvVoiceVirtualPortId 2.1.866.30.20.30.10.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER vpVoix(1), vpIp(2)  

dcvVoiceTransportTable 2.1.866.30.20.30.10.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvVoiceTransportEntry

dcvVoiceTransportEntry 2.1.866.30.20.30.10.2.1
An entry of dcvVoiceTransportTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvVoiceTransportEntry  

dcvVoiceTransProfileId 2.1.866.30.20.30.10.2.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

dcvVoiceTransEncapsulationMode 2.1.866.30.20.30.10.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER frf(1), private(2)  

dcvVoiceTransMaxPayLoadNumber 2.1.866.30.20.30.10.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

dcvVoiceTransCompressionAlgorithm 2.1.866.30.20.30.10.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER g729(1), g729A(2)  

dcvVoiceTransJitterCompensation 2.1.866.30.20.30.10.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..9  

dcvVoiceTransVoicePacketsCombination 2.1.866.30.20.30.10.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

dcvVoiceTransQosBc 2.1.866.30.20.30.10.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s9600(1), s14400(2), s19200(3), s32000(4), s38400(5), s48000(6)  

dcvVoiceTransQosBe 2.1.866.30.20.30.10.2.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s9600(1), s14400(2), s19200(3), s32000(4), s38400(5), s48000(6)  

dcvVoiceTransQosCir 2.1.866.30.20.30.10.2.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s9600(1), s14400(2), s19200(3), s32000(4), s38400(5), s48000(6)  

dcvVoiceSuscriberTable 2.1.866.30.20.30.10.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvVoiceSuscriberEntry

dcvVoiceSuscriberEntry 2.1.866.30.20.30.10.3.1
An entry of dcvVoiceSuscriberTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvVoiceSuscriberEntry  

dcvVoiceSuscrOrderNumber 2.1.866.30.20.30.10.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..9  

dcvVoiceSuscrNumber 2.1.866.30.20.30.10.3.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..21)  

dcvVoiceSuscrStatus 2.1.866.30.20.30.10.3.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dcvVoiceSuscrTransportNetwork 2.1.866.30.20.30.10.3.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fr(1), other(2)  

dcvVoiceSuscrTransportNetworkAddress 2.1.866.30.20.30.10.3.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

dcvVoiceSuscrTransportProfileId 2.1.866.30.20.30.10.3.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

dcvVoiceSuscrRemovedDigitNumber 2.1.866.30.20.30.10.3.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..21  

dcvVoiceSuscrInsPrefix 2.1.866.30.20.30.10.3.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

dcvVoiceSuscrInsSuffix 2.1.866.30.20.30.10.3.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

dcvVoiceSwTable 2.1.866.30.20.30.10.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvVoiceSwEntry

dcvVoiceSwEntry 2.1.866.30.20.30.10.4.1
An entry of dcvVoiceSwTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvVoiceSwEntry  

dcvVoiceSwOrderNumber 2.1.866.30.20.30.10.4.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..9  

dcvVoiceSwSuscriberNumber 2.1.866.30.20.30.10.4.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..21)  

dcvVoiceSwStatus 2.1.866.30.20.30.10.4.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dcvVoiceSwLogPortSetId 2.1.866.30.20.30.10.4.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9  

dcvVoiceSwRemovedDigitNumber 2.1.866.30.20.30.10.4.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..21  

dcvVoiceSwInsPrefix 2.1.866.30.20.30.10.4.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

dcvVoiceSwInsSuffix 2.1.866.30.20.30.10.4.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

dcvDialingReceptTable 2.1.866.30.20.30.10.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvDialingReceptEntry

dcvDialingReceptEntry 2.1.866.30.20.30.10.5.1
An entry of dcvDialingReceptTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvDialingReceptEntry  

dcvDialRxSuscriberNumber 2.1.866.30.20.30.10.5.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..21)  

dcvDialRxStatus 2.1.866.30.20.30.10.5.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dcvDialRxNumberLength 2.1.866.30.20.30.10.5.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..21  

dcvDialRxEndOfDialingTimer 2.1.866.30.20.30.10.5.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

dcvVoiceLogPort 2.1.866.30.20.30.10.10
OBJECT IDENTIFIER    

dcvVoiceLogicalPortTable 2.1.866.30.20.30.10.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvVoiceLogicalPortEntry

dcvVoiceLogicalPortEntry 2.1.866.30.20.30.10.10.1.1
An entry of dcvVoiceLogicalPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvVoiceLogicalPortEntry  

dcvVoiceLogPortId 2.1.866.30.20.30.10.10.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..31  

dcvVoiceLogPortStatus 2.1.866.30.20.30.10.10.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dcvVoiceLogPortType 2.1.866.30.20.30.10.10.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER tsPCMPermanent(1), tsPCMSwitched(2)  

dcvProfileTone 2.1.866.30.20.30.10.10.5
OBJECT IDENTIFIER    

dcvToneGenTable 2.1.866.30.20.30.10.10.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvToneGenEntry

dcvToneGenEntry 2.1.866.30.20.30.10.10.5.1.1
An entry of dcvToneGenTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvToneGenEntry  

dcvToneGenProfileId 2.1.866.30.20.30.10.10.5.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dcvToneGenLevel 2.1.866.30.20.30.10.10.5.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..60  

dcvToneTable 2.1.866.30.20.30.10.10.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvToneEntry

dcvToneEntry 2.1.866.30.20.30.10.10.5.2.1
An entry of dcvToneTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvToneEntry  

dcvToneProfileId 2.1.866.30.20.30.10.10.5.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dcvToneType 2.1.866.30.20.30.10.10.5.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dialTone(1), trouble(2), congestion(3), busy(4), callBack(5)  

dcvToneEnable 2.1.866.30.20.30.10.10.5.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

dcvToneFreq1 2.1.866.30.20.30.10.10.5.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

dcvToneDuration1 2.1.866.30.20.30.10.10.5.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..500  

dcvToneFreq2 2.1.866.30.20.30.10.10.5.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

dcvToneDuration2 2.1.866.30.20.30.10.10.5.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..500  

dcvVoiceLogicalPortTSPCM 2.1.866.30.20.30.10.10.10
OBJECT IDENTIFIER    

dcvTSPCMPerm 2.1.866.30.20.30.10.10.10.1
OBJECT IDENTIFIER    

dcvTSPCMPermTable 2.1.866.30.20.30.10.10.10.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvTSPCMPermEntry

dcvTSPCMPermEntry 2.1.866.30.20.30.10.10.10.1.1.1
An entry of dcvTSPCMPermTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvTSPCMPermEntry  

dcvTSPCMPermLpId 2.1.866.30.20.30.10.10.10.1.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..31  

dcvTSPCMPermCommunicationMode 2.1.866.30.20.30.10.10.10.1.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2)  

dcvTSPCMPermRemoteNumber 2.1.866.30.20.30.10.10.10.1.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

dcvTSPCMPermConfigId 2.1.866.30.20.30.10.10.10.1.1.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dcvTSPCMPermChannIfId 2.1.866.30.20.30.10.10.10.1.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

dcvTSPCMSw 2.1.866.30.20.30.10.10.10.2
OBJECT IDENTIFIER    

dcvTSPCMSwTable 2.1.866.30.20.30.10.10.10.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvTSPCMSwEntry

dcvTSPCMSwEntry 2.1.866.30.20.30.10.10.10.2.1.1
An entry of dcvTSPCMSwTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvTSPCMSwEntry  

dcvTSPCMSwLpId 2.1.866.30.20.30.10.10.10.2.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..31  

dcvTSPCMSwLogPortSetId 2.1.866.30.20.30.10.10.10.2.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9  

dcvTSPCMSwCallType 2.1.866.30.20.30.10.10.10.2.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER incoming(1), outgoing(2), mixed(3)  

dcvTSPCMSwRemoteNumber 2.1.866.30.20.30.10.10.10.2.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..21)  

dcvTSPCMSwConfigId 2.1.866.30.20.30.10.10.10.2.1.1.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dcvTSPCMSwChannIfId 2.1.866.30.20.30.10.10.10.2.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

dcvCASConfigTable 2.1.866.30.20.30.10.10.10.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvCASConfigEntry

dcvCASConfigEntry 2.1.866.30.20.30.10.10.10.5.1
An entry of dcvCASConfigTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvCASConfigEntry  

dcvCASConfId 2.1.866.30.20.30.10.10.10.5.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dcvCASConfSignallingTransport 2.1.866.30.20.30.10.10.10.5.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), a(2), ab(3), abcd(4)  

dcvCASConfCallSignalling 2.1.866.30.20.30.10.10.10.5.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nColisee(1), uColisee(2), simm(3), sDelay(4), swink(5), noResp(6)  

dcvCASConfDialingMode 2.1.866.30.20.30.10.10.10.5.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dec(1), dtmf(2)  

dcvCASConfDialingTimeOut 2.1.866.30.20.30.10.10.10.5.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

dcvCASConfSigChannelDiscTimeOut 2.1.866.30.20.30.10.10.10.5.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

dcvCASConfTimeBetweenSuccOutCall 2.1.866.30.20.30.10.10.10.5.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

dcvCASConfLineInterfacePolarity 2.1.866.30.20.30.10.10.10.5.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), inverted(2)  

dcvCASConfMinLineSeizureAckTime 2.1.866.30.20.30.10.10.10.5.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..50  

dcvCASConfMaxLineSeizureAckTime 2.1.866.30.20.30.10.10.10.5.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..50  

dcvCASConfLineSeizureAckTime 2.1.866.30.20.30.10.10.10.5.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..50  

dcvCASConfClearToIncCallTime 2.1.866.30.20.30.10.10.10.5.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 3..50  

dcvCASConfSeizureAckPulseDuration 2.1.866.30.20.30.10.10.10.5.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

dcvCASConfMinSeizureAckPulseDuration 2.1.866.30.20.30.10.10.10.5.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

dcvCASConfDialingFormat 2.1.866.30.20.30.10.10.10.5.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ds1(1), ds2(2)  

dcvCASConfInterdigitTime 2.1.866.30.20.30.10.10.10.5.1.16
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

dcvCASConfPauseTime 2.1.866.30.20.30.10.10.10.5.1.17
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

dcvCASConfDtmfDigitTime 2.1.866.30.20.30.10.10.10.5.1.18
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..10  

dcvCASConfDtmfDigitLevel 2.1.866.30.20.30.10.10.10.5.1.19
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..40  

dcvCASConfDelayBeforeDialing 2.1.866.30.20.30.10.10.10.5.1.20
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

dcvCASConfDigitReceptionTimeOut 2.1.866.30.20.30.10.10.10.5.1.21
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

dcvCASConfEndOfDialingTimer 2.1.866.30.20.30.10.10.10.5.1.22
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..60  

dcvCASConfToneProfile 2.1.866.30.20.30.10.10.10.5.1.23
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..0  

dcvCASConfIdleState 2.1.866.30.20.30.10.10.10.5.1.24
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

dcvCASConfAlarmState 2.1.866.30.20.30.10.10.10.5.1.25
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

dcvDigitalLines 2.1.866.30.20.30.10.15
OBJECT IDENTIFIER    

dcvIfPCM 2.1.866.30.20.30.10.15.1
OBJECT IDENTIFIER    

dcvIfPCMPhysTable 2.1.866.30.20.30.10.15.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvIfPCMPhysEntry

dcvIfPCMPhysEntry 2.1.866.30.20.30.10.15.1.1.1
An entry of dcvIfPCMPhysTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvIfPCMPhysEntry  

dcvIfPCMPhysIfId 2.1.866.30.20.30.10.15.1.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pcm1(1), other(2)  

dcvIfPCMPhysTypeId 2.1.866.30.20.30.10.15.1.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER e1(1), t1-12(2), t1-24(3)  

dcvIfPCMPhysPhysicalPort 2.1.866.30.20.30.10.15.1.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v1(1), v2(2)  

dcvIfPCMChannelTable 2.1.866.30.20.30.10.15.1.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvIfPCMChannelEntry

dcvIfPCMChannelEntry 2.1.866.30.20.30.10.15.1.2.1
An entry of dcvIfPCMChannelTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvIfPCMChannelEntry  

dcvIfPCMChannelIfId 2.1.866.30.20.30.10.15.1.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..31  

dcvIfPCMChannelStatus 2.1.866.30.20.30.10.15.1.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

dcvIfPCMChannelVoiceProfId 2.1.866.30.20.30.10.15.1.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..9  

dcvIfPCMChannelPhysIf 2.1.866.30.20.30.10.15.1.2.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pcm1(1), other(2)  

dcvVoiceProfileTable 2.1.866.30.20.30.10.15.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvVoiceProfileEntry

dcvVoiceProfileEntry 2.1.866.30.20.30.10.15.5.1
An entry of dcvVoiceProfileTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvVoiceProfileEntry  

dcvVoiceProfId 2.1.866.30.20.30.10.15.5.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..9  

dcvVoiceProfTransmitLevel 2.1.866.30.20.30.10.15.5.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..24  

dcvVoiceProfReceiveLevel 2.1.866.30.20.30.10.15.5.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

dcvVoiceProfSilenceDetection 2.1.866.30.20.30.10.15.5.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2), cng(3)  

dcvVoiceProfSilenceDetectionLevel 2.1.866.30.20.30.10.15.5.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER low(1), medium(2), high(3)  

dcvVoiceProfEchoCancellation 2.1.866.30.20.30.10.15.5.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

dcvVoiceProfEchoCancellationLength 2.1.866.30.20.30.10.15.5.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER low(1), medium(2), high(3)  

dcvVoiceProfNoiseFramesPeriodicity 2.1.866.30.20.30.10.15.5.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..10  

dcvVoiceProfLoopActivation 2.1.866.30.20.30.10.15.5.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), local(2), remote(3)  

dcvVoiceProfFaxActivation 2.1.866.30.20.30.10.15.5.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

dcvVoiceProfMaximumFaxSpeed 2.1.866.30.20.30.10.15.5.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s9600(1), s4800(2)  

dcvVoiceProfCESMode 2.1.866.30.20.30.10.15.5.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

dcvVoiceProfCESModeAverageDelay 2.1.866.30.20.30.10.15.5.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..15  

dcvVoicePhysicalPortTable 2.1.866.30.20.30.10.15.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcvVoicePhysicalPortEntry

dcvVoicePhysicalPortEntry 2.1.866.30.20.30.10.15.10.1
An entry of dcvVoicePhysicalPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DcvVoicePhysicalPortEntry  

dcvVoicePhysPortId 2.1.866.30.20.30.10.15.10.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v1(1), v2(2)  

dcvVoicePhysPortConnector 2.1.866.30.20.30.10.15.10.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tdm(1), other(2)