PANDATEL-FOBUS-MODEM-MIB
File:
PANDATEL-FOBUS-MODEM-MIB.mib (7835 bytes)
Imported modules
Imported symbols
Defined Types
FobusTableEntry |
|
SEQUENCE |
|
|
|
|
mdmRack |
INTEGER |
|
|
mdmModem |
INTEGER |
|
|
mdmPosition |
INTEGER |
|
|
mdmModemName |
DisplayString |
|
|
mdmBackupStatus |
INTEGER |
|
|
mdmActiveLink |
INTEGER |
|
|
mdmOperationMode |
INTEGER |
|
|
mdmAlarmConditionPort1 |
INTEGER |
|
|
mdmAlarmConditionPort2 |
INTEGER |
|
|
mdmAlarmConditionPort3 |
INTEGER |
|
|
mdmTXLaserStatusPort2 |
INTEGER |
|
|
mdmTXLaserStatusPort3 |
INTEGER |
|
Defined Values
fobus-modem |
1.3.6.1.4.1.760.1.1.2.1.10.10000.2.501 |
OBJECT IDENTIFIER |
|
|
|
fobus |
1.3.6.1.4.1.760.1.1.2.1.10.501 |
OBJECT IDENTIFIER |
|
|
|
fobusModemTable |
1.3.6.1.4.1.760.1.1.2.1.10.501.1 |
This table contains information about all FOBUS units in all racks. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
FobusTableEntry |
|
fobusTableEntry |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1 |
The index of the table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
FobusTableEntry |
|
|
mdmRack |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.1 |
The index of the rack where the unit is installed. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mdmModem |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.2 |
This entry displays the slot number where the corresponding
unit is installed in the rack. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mdmPosition |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.3 |
This entry displays the location of the corresponding unit:
'local' or 'remote'. The unit which is plugged into a managed
rack is 'local', the counterpart is 'remote'. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
local(1), remote(2) |
|
mdmModemName |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.5 |
The verbal name of this unit. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
mdmBackupStatus |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.11 |
The backup status of the unit. The available values depend on the
generation of the unit. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), inactive(2), active(3), not-available(4), available(5), disable(6) |
|
mdmActiveLink |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.12 |
This entry displays the line port used for data transmission. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
line-port-2(2), line-port-3(3), disable(90) |
|
mdmOperationMode |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.66 |
This entry defines if data is transmitted via port 2 or port 3:
'forced-port2', 'forced-port3', 'automatic'. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), forced-port2(3), forced-port3(4), automatic(5) |
|
mdmAlarmConditionPort1 |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.110 |
The alarm trigger mode at port 1: 'disable', i.e. no alarm is
triggered, or 'link-signal', i.e. an alarm is triggered if the
link is down. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disable(2), link-signal(3) |
|
mdmAlarmConditionPort2 |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.111 |
The alarm trigger mode at port 2: 'disable', i.e. no alarm
is triggered, 'no-link-signal', i.e. an alarm is triggered if
the link is down, 'laser-fail', i.e. an alarm is triggered
if the laser diode is defective, or 'no-link-signal-or-laser-fail',
i.e. the link is down or the laser diode is defective. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disable(2), no-link-signal(3), laser-fail(4), no-link-signal-or-laser-fail(5) |
|
mdmAlarmConditionPort3 |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.112 |
The alarm trigger mode at port 3: 'disable', i.e. no alarm
is triggered, 'no-link-signal', i.e. an alarm is triggered if
the link is down, 'laser-fail', i.e. an alarm is triggered
if the laser diode is defective, or 'no-link-signal-or-laser-fail',
i.e. the link is down or the laser diode is defective. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disable(2), no-link-signal(3), laser-fail(4), no-link-signal-or-laser-fail(5) |
|
mdmTXLaserStatusPort2 |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.121 |
This entry indicates if the laser diode at port 2 is
transmitting data ('enable') or not ('disable'). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disable(2), enable(3) |
|
mdmTXLaserStatusPort3 |
1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.122 |
This entry indicates if the laser diode at port 3 is
transmitting data ('enable') or not ('disable'). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disable(2), enable(3) |
|