OPTIX-SONET-LPBK-MIB-V2
File:
OPTIX-SONET-LPBK-MIB-V2.mib (8674 bytes)
Imported modules
Imported symbols
Defined Types
LpbkType |
|
Enter the description for the LpbkType TEXTUAL-CONVENTION converted from type assignment. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
noloop(255), terminal(1), facility(2), crs(3), ds1feac(4), ds3feac(5), fac2ni(6) |
|
LpbkStateEntry |
|
SEQUENCE |
|
|
|
|
lpbkStateMOD2 |
MOD2Type |
|
|
lpbkStateSlot |
Gauge32 |
|
|
lpbkStatePort |
Gauge32 |
|
|
lpbkStatePath |
Gauge32 |
|
|
lpbkStateVT |
Gauge32 |
|
|
lpbkStateLpbkType |
LpbkType |
|
|
lpbkStateTimeout |
Gauge32 |
|
LpbkFlagEntry |
|
SEQUENCE |
|
|
|
|
lpbkFlagMOD2 |
MOD2Type |
|
|
lpbkFlagSlot |
Gauge32 |
|
|
lpbkFlagPort |
Gauge32 |
|
|
lpbkFlagPath |
Gauge32 |
|
|
lpbkFlagVT |
Gauge32 |
|
|
lpbkFlagLpbkType |
LpbkType |
|
|
lpbkFlagEnFlag |
INTEGER |
|
|
lpbkFlagTimeout |
Gauge32 |
|
Defined Values
optixSonetMaintenance |
1.3.6.1.4.1.2011.2.25.3.20.50 |
This module describes the Loopback interface of Huawei SONET transmit platform
|
MODULE-IDENTITY |
|
|
|
lpbkStateTable |
1.3.6.1.4.1.2011.2.25.3.20.50.10.10 |
Loopback state table
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
LpbkStateEntry |
|
lpbkStateEntry |
1.3.6.1.4.1.2011.2.25.3.20.50.10.10.1 |
Loopback state entry
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LpbkStateEntry |
|
|
lpbkStateMOD2 |
1.3.6.1.4.1.2011.2.25.3.20.50.10.10.1.1 |
The modifier that identifies the type of the facility |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
MOD2Type |
|
|
lpbkStateSlot |
1.3.6.1.4.1.2011.2.25.3.20.50.10.10.1.2 |
Slot number.
This will indicate what is the slot
of the object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
lpbkStatePort |
1.3.6.1.4.1.2011.2.25.3.20.50.10.10.1.3 |
Port Number.
This will indicate what is the Port
of the object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
lpbkStatePath |
1.3.6.1.4.1.2011.2.25.3.20.50.10.10.1.4 |
Path number.
This will indicate what is the Path
of the object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
lpbkStateVT |
1.3.6.1.4.1.2011.2.25.3.20.50.10.10.1.5 |
VT path number.
This will indicate what is the VT path
of the object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
lpbkStateLpbkType |
1.3.6.1.4.1.2011.2.25.3.20.50.10.10.1.6 |
The loopback type of the facility
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
LpbkType |
|
|
lpbkStateTimeout |
1.3.6.1.4.1.2011.2.25.3.20.50.10.10.1.7 |
The remnant time that loop-back will be released.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
lpbkFlagTable |
1.3.6.1.4.1.2011.2.25.3.20.50.10.20 |
Loopback Enable table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
LpbkFlagEntry |
|
lpbkFlagEntry |
1.3.6.1.4.1.2011.2.25.3.20.50.10.20.1 |
Loopback Enable entry |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LpbkFlagEntry |
|
|
lpbkFlagMOD2 |
1.3.6.1.4.1.2011.2.25.3.20.50.10.20.1.1 |
The modifier that identifies the type of the facility |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
MOD2Type |
|
|
lpbkFlagSlot |
1.3.6.1.4.1.2011.2.25.3.20.50.10.20.1.2 |
Slot number.
This will indicate what is the slot
of the object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
lpbkFlagPort |
1.3.6.1.4.1.2011.2.25.3.20.50.10.20.1.3 |
Port Number.
This will indicate what is the Port
of the object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
lpbkFlagPath |
1.3.6.1.4.1.2011.2.25.3.20.50.10.20.1.4 |
Path number.
This will indicate what is the Path
of the object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
lpbkFlagVT |
1.3.6.1.4.1.2011.2.25.3.20.50.10.20.1.5 |
VT path number.
This will indicate what is the VT path
of the object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
lpbkFlagLpbkType |
1.3.6.1.4.1.2011.2.25.3.20.50.10.20.1.6 |
The loopback type of the facility
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
LpbkType |
|
|
lpbkFlagEnFlag |
1.3.6.1.4.1.2011.2.25.3.20.50.10.20.1.7 |
T1 or T3 remote loop-back enable flag
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
lpbkFlagTimeout |
1.3.6.1.4.1.2011.2.25.3.20.50.10.20.1.8 |
The automatic release time of loopback. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
optixSonetMaintenanceGroups |
1.3.6.1.4.1.2011.2.25.3.20.50.11.1 |
OBJECT IDENTIFIER |
|
|
|
currentObjectGroup |
1.3.6.1.4.1.2011.2.25.3.20.50.11.1.1 |
Enter the description of the created OBJECT-GROUP. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
optixSonetMaintenanceCompliances |
1.3.6.1.4.1.2011.2.25.3.20.50.11.2 |
OBJECT IDENTIFIER |
|
|
|
basicCompliance |
1.3.6.1.4.1.2011.2.25.3.20.50.11.2.1 |
Enter the description of the created MODULE-COMPLIANCE. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|