OPTIX-SONET-EQPTMGT-MIB-V2

File: OPTIX-SONET-EQPTMGT-MIB-V2.mib (11099 bytes)

Imported modules

OPTIX-OID-MIB SNMPv2-CONF SNMPv2-SMI
SNMPv2-TC

Imported symbols

optixProvisionSonet OBJECT-GROUP MODULE-COMPLIANCE
Integer32 Gauge32 OBJECT-TYPE
MODULE-IDENTITY TEXTUAL-CONVENTION

Defined Types

IntfType  
Enter the description for the IntfType TEXTUAL-CONVENTION converted from type assignment.
TEXTUAL-CONVENTION    
  INTEGER ds1-asyn-vt1(1), ds3-asyn-sts1(10), ec(12), ds3-tmux-ds1(13), ds3-srv-ds1(17), uas(65), mix(100), invalid(254)  

OptixsonetCardInfoEntry  
SEQUENCE    
  cardIndexSlotId Gauge32
  cardIndexSfpId Gauge32
  cardProvisionType OCTET STRING
  cardPhysicalType OCTET STRING
  cardInterfaceType IntfType
  cardBandwidth Integer32
  cardSerialNum OCTET STRING
  cardCLEICode OCTET STRING
  cardPartNum OCTET STRING
  cardDOM OCTET STRING
  cardPCBVersion OCTET STRING
  cardSWVersion OCTET STRING
  cardFPGAVersion OCTET STRING
  cardEPLDVersion OCTET STRING
  cardBIOSVersion OCTET STRING
  cardMAC OCTET STRING
  cardPSTState OCTET STRING
  cardSSTState OCTET STRING
  cardTPSPriority Gauge32
  cardSwitchState INTEGER
  cardDescription OCTET STRING

Defined Values

optixsonetEqptMgt 1.3.6.1.4.1.2011.2.25.4.20.3
Enter the description for this MIB module.
MODULE-IDENTITY    

optixsonetCardInfoTable 1.3.6.1.4.1.2011.2.25.4.20.3.1
This table describes the equipment unit management interface of Huawei SONET transmit platform
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptixsonetCardInfoEntry

optixsonetCardInfoEntry 1.3.6.1.4.1.2011.2.25.4.20.3.1.1
The equipment unit management entry
Status: current Access: not-accessible
OBJECT-TYPE    
  OptixsonetCardInfoEntry  

cardIndexSlotId 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.1
Slot number. This will indicate what is the slot of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cardIndexSfpId 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.2
SFP identifier. This will indicate what is the SFP Slot of the object.For the card unit, I will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cardProvisionType 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.3
It means the logical unit type provisioned by user.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

cardPhysicalType 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.4
It means the physical unit type inserted in the slot.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

cardInterfaceType 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.5
The AID unit interface type.This parameter is optional and can be used only for tributary units
Status: current Access: read-only
OBJECT-TYPE    
  IntfType  

cardBandwidth 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.6
The available bandwidth of the unit when it is provisioned in the slot. It is displayed when the Ethernet unit, the OC-N unit or the tributary unit is provisioned. It is the minimum value of the slot bus bandwidth and bandwidth of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cardSerialNum 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.7
The serial number for the equipment. Valid value is a string and is optional.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

cardCLEICode 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.8
The CLEI code for the equipment. Valid value is a string and is optional.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

cardPartNum 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.9
Part number of the unit. Valid value is a unique 8-digit number for the unit.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

cardDOM 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.10
The date when the unit was manufactured and is optional.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

cardPCBVersion 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.11
The PCB version for the equipment. Valid value is a string and is optional.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

cardSWVersion 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.12
The software version for the equipment.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

cardFPGAVersion 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.13
The FPGA version for the equipment. Valid value is a string and is optional.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

cardEPLDVersion 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.14
The EPLD version for the equipment. Valid value is a string and is optional.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

cardBIOSVersion 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.15
The BIOS version for the equipment. Valid value for is a string and is optional.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

cardMAC 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.16
The MAC address of a common control unit. Valid value is a string like 00-B0-D0-E3-4C-DE and is optional.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

cardPSTState 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.17
means the primary state of the entity.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

cardSSTState 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.18
means the secondary state of the entity.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

cardTPSPriority 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.19
The priority of the AID unit if the unit is a working unit of a DSn (TPS) protection group. For any other units, this parameter is not available. This attribute will be used when multi-units fault in a DSn (TPS) protection group.Valid values are list below Value Description 1 The highest priority for the unit in a TPS protection group 2 The secondary priority for the unit in a TPS protection group 3 The third priority for the unit in a TPS protection group 4 The lowest priority for the unit in a TPS protection group
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cardSwitchState 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.20
The switch state of the AID unit if the unit is a unit of a DSn (TPS) protection group. Switch state of SONET equipment protection Value Description AUTO_SW Automatic switch DNR Do not revert FRCD Forced switch IDLE Idle LOCKOUT Lock to the working unit MAN Manually switch WTR Wait to restore
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stateDNR(1), stateWTR(2), stateMAN(3), stateAUTOSW(4), stateFRCD(5), stateLOCK(6), stateINVALID(254), stateIDLE(255)  

cardDescription 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.21
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

optixsonetEqptMgtConformance 1.3.6.1.4.1.2011.2.25.4.20.3.2
OBJECT IDENTIFIER    

optixsonetEqptMgtGroups 1.3.6.1.4.1.2011.2.25.4.20.3.2.1
OBJECT IDENTIFIER    

currentObjectGroup 1.3.6.1.4.1.2011.2.25.4.20.3.2.1.1
Enter the description of the created OBJECT-GROUP.
Status: current Access: read-only
OBJECT-GROUP    

optixsonetEqptMgtCompliances 1.3.6.1.4.1.2011.2.25.4.20.3.2.2
OBJECT IDENTIFIER    

basicCompliance 1.3.6.1.4.1.2011.2.25.4.20.3.2.2.1
Enter the description of the created MODULE-COMPLIANCE.
Status: current Access: read-only
MODULE-COMPLIANCE