OMNI-gx2RX200-MIB
File:
OMNI-gx2RX200-MIB.mib (69235 bytes)
Imported modules
Imported symbols
Defined Types
Gx2Rx200AnalogEntry |
|
SEQUENCE |
|
|
|
|
rxgx2Rx200AnalogTableIndex |
INTEGER |
|
|
rxlabelModTemp |
DisplayString |
Size(0..80) |
|
rxuomModTemp |
DisplayString |
Size(0..80) |
|
rxmajorHighModTemp |
Float |
|
|
rxmajorLowModTemp |
Float |
|
|
rxminorHighModTemp |
Float |
|
|
rxminorLowModTemp |
Float |
|
|
rxcurrentValueModTemp |
Float |
|
|
rxstateFlagModTemp |
INTEGER |
|
|
rxminValueModTemp |
Float |
|
|
rxmaxValueModTemp |
Float |
|
|
rxalarmStateModTemp |
INTEGER |
|
|
rxlabelFanCurrent |
DisplayString |
Size(0..80) |
|
rxuomFanCurrent |
DisplayString |
Size(0..80) |
|
rxmajorHighFanCurrent |
Float |
|
|
rxmajorLowFanCurrent |
Float |
|
|
rxminorHighFanCurrent |
Float |
|
|
rxminorLowFanCurrent |
Float |
|
|
rxcurrentValueFanCurrent |
Float |
|
|
rxstateFlagFanCurrent |
INTEGER |
|
|
rxminValueFanCurrent |
Float |
|
|
rxmaxValueFanCurrent |
Float |
|
|
rxalarmStateFanCurrent |
INTEGER |
|
|
rxlabel12Volt |
DisplayString |
Size(0..80) |
|
rxuom12Volt |
DisplayString |
Size(0..80) |
|
rxmajorHigh12Volt |
Float |
|
|
rxmajorLow12Volt |
Float |
|
|
rxminorHigh12Volt |
Float |
|
|
rxminorLow12Volt |
Float |
|
|
rxcurrentValue12Volt |
Float |
|
|
rxstateFlag12Volt |
INTEGER |
|
|
rxminValue12Volt |
Float |
|
|
rxmaxValue12Volt |
Float |
|
|
rxalarmState12Volt |
INTEGER |
|
|
rxlabelOptPower |
DisplayString |
Size(0..80) |
|
rxuomOptPower |
DisplayString |
Size(0..80) |
|
rxmajorHighOptPower |
Float |
|
|
rxmajorLowOptPower |
Float |
|
|
rxminorHighOptPower |
Float |
|
|
rxminorLowOptPower |
Float |
|
|
rxcurrentValueOptPower |
Float |
|
|
rxstateFlagOptPower |
INTEGER |
|
|
rxminValueOptPower |
Float |
|
|
rxmaxValueOptPower |
Float |
|
|
rxalarmStateOptPower |
INTEGER |
|
Gx2Rx200DigitalEntry |
|
SEQUENCE |
|
|
|
|
rxgx2Rx200DigitalTableIndex |
INTEGER |
|
|
rxlabelMode |
DisplayString |
Size(0..80) |
|
rxvalueMode |
INTEGER |
|
|
rxenumMode |
DisplayString |
Size(0..80) |
|
rxstateFlagMode |
INTEGER |
|
|
rxlabelWavelength |
DisplayString |
Size(0..80) |
|
rxvalueWavelength |
INTEGER |
|
|
rxenumWavelength |
DisplayString |
Size(0..80) |
|
rxstateFlagWavelength |
INTEGER |
|
|
rxlabelAttnSetting |
DisplayString |
Size(0..80) |
|
rxvalueAttnSetting |
INTEGER |
|
|
rxenumAttnSetting |
DisplayString |
Size(0..80) |
|
rxstateFlagAttnSetting |
INTEGER |
|
|
rxlabelSwModeSetting |
DisplayString |
Size(0..80) |
|
rxvalueSwModeSetting |
INTEGER |
|
|
rxenumSwModeSetting |
DisplayString |
Size(0..80) |
|
rxstateFlagSwModeSetting |
INTEGER |
|
|
rxlabelSwModeThreshold |
DisplayString |
Size(0..80) |
|
rxvalueSwModeThreshold |
INTEGER |
|
|
rxenumSwModeThreshold |
DisplayString |
Size(0..80) |
|
rxstateFlagSwModeThreshold |
INTEGER |
|
|
rxlabelFactoryDefault |
DisplayString |
Size(0..80) |
|
rxvalueFactoryDefault |
INTEGER |
|
|
rxenumFactoryDefault |
DisplayString |
Size(0..80) |
|
rxstateFlagFactoryDefault |
INTEGER |
|
Gx2Rx200StatusEntry |
|
SEQUENCE |
|
|
|
|
rxgx2Rx200StatusTableIndex |
INTEGER |
|
|
rxlabelBoot |
DisplayString |
Size(0..80) |
|
rxvalueBoot |
INTEGER |
|
|
rxstateflagBoot |
INTEGER |
|
|
rxlabelFlash |
DisplayString |
Size(0..80) |
|
rxvalueFlash |
INTEGER |
|
|
rxstateflagFlash |
INTEGER |
|
|
rxlabelFactoryDataCRC |
DisplayString |
Size(0..80) |
|
rxvalueFactoryDataCRC |
INTEGER |
|
|
rxstateflagFactoryDataCRC |
INTEGER |
|
|
rxlabelAlarmDataCRC |
DisplayString |
Size(0..80) |
|
rxvalueAlarmDataCRC |
INTEGER |
|
|
rxstateflagAlarmDataCRC |
INTEGER |
|
|
rxlabelCalibrationDataCRC |
DisplayString |
Size(0..80) |
|
rxvalueCalibrationDataCRC |
INTEGER |
|
|
rxstateflagCalibrationDataCRC |
INTEGER |
|
|
rxlabelThermalCompCRC |
DisplayString |
Size(0..80) |
|
rxvalueThermalCompCRC |
INTEGER |
|
|
rxstateflagThermalCompCRC |
INTEGER |
|
|
rxlabelHW |
DisplayString |
Size(0..80) |
|
rxvalueHW |
INTEGER |
|
|
rxstateflagHW |
INTEGER |
|
|
rxlabelOptSig |
DisplayString |
Size(0..80) |
|
rxvalueOptSig |
INTEGER |
|
|
rxstateflagOptSig |
INTEGER |
|
Gx2Rx200FactoryEntry |
|
SEQUENCE |
|
|
|
|
rxgx2Rx200FactoryTableIndex |
INTEGER |
|
|
rxbootControlByte |
INTEGER |
|
|
rxbootStatusByte |
INTEGER |
|
|
rxbank0CRC |
INTEGER |
|
|
rxbank1CRC |
INTEGER |
|
|
rxprgEEPROMByte |
INTEGER |
|
|
rxfactoryCRC |
INTEGER |
|
|
rxcalculateCRC |
INTEGER |
|
|
rxhourMeter |
INTEGER |
|
|
rxflashPrgCntA |
INTEGER |
|
|
rxflashPrgCntB |
INTEGER |
|
|
rxfwRev0 |
DisplayString |
Size(0..80) |
|
rxfwRev1 |
DisplayString |
Size(0..80) |
Gx2Rx200HoldTimeEntry |
|
SEQUENCE |
|
|
|
|
rxgx2Rx200HoldTimeTableIndex |
INTEGER |
|
|
rxgx2Rx200HoldTimeSpecIndex |
INTEGER |
|
|
rxgx2Rx200HoldTimeData |
INTEGER |
|
Defined Values
gx2Rx200AnalogTable |
1.3.6.1.4.1.1166.6.1.2.6.2 |
This table contains gx2Rx200 specific parameters with
nominal and current values. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Gx2Rx200AnalogEntry |
|
gx2Rx200AnalogEntry |
1.3.6.1.4.1.1166.6.1.2.6.2.1 |
This list contains digital product class and the
associated RF channel parameters and descriptions. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Gx2Rx200AnalogEntry |
|
|
gx2Rx200DigitalTable |
1.3.6.1.4.1.1166.6.1.2.6.3 |
This table contains gx2Rx200 specific parameters with
nominal and current values. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Gx2Rx200DigitalEntry |
|
gx2Rx200DigitalEntry |
1.3.6.1.4.1.1166.6.1.2.6.3.2 |
This list contains digital product class and the
associated RF channel parameters and descriptions. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Gx2Rx200DigitalEntry |
|
|
gx2Rx200StatusTable |
1.3.6.1.4.1.1166.6.1.2.6.4 |
This table contains gx2Rx200 specific parameters with
nominal and current values. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Gx2Rx200StatusEntry |
|
gx2Rx200StatusEntry |
1.3.6.1.4.1.1166.6.1.2.6.4.3 |
This list contains digital product class and the
associated RF channel parameters and descriptions. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Gx2Rx200StatusEntry |
|
|
gx2Rx200FactoryTable |
1.3.6.1.4.1.1166.6.1.2.6.5 |
This table contains gx2Rx200 specific parameters with
nominal and current values. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Gx2Rx200FactoryEntry |
|
gx2Rx200FactoryEntry |
1.3.6.1.4.1.1166.6.1.2.6.5.4 |
This list contains digital product class and the
associated RF channel parameters and descriptions. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Gx2Rx200FactoryEntry |
|
|
gx2Rx200HoldTimeEntry |
1.3.6.1.4.1.1166.6.1.2.6.6.5 |
This list contains digital product class and the
associated RF channel parameters and descriptions. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Gx2Rx200HoldTimeEntry |
|
|
rxgx2Rx200AnalogTableIndex |
1.3.6.1.4.1.1166.6.1.2.6.2.1.1 |
The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..4294967295 |
|
rxlabelModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.2 |
The value of this object provides the label of the
Module Temperature Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxuomModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.3 |
The value of this object provides the Unit of Measure of the
Module Temperature Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxmajorHighModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.4 |
The value of this object provides the Major High alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxmajorLowModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.5 |
The value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxminorHighModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.6 |
The value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxminorLowModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.7 |
The value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxcurrentValueModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.8 |
The value of this object provides the Current value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxstateFlagModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.9 |
The value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxminValueModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.10 |
The value of this object provides the minimum value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxmaxValueModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.11 |
The value of this object provides the maximum value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxalarmStateModTemp |
1.3.6.1.4.1.1166.6.1.2.6.2.1.12 |
The value of this object provides the curent alarm state of
the Module Temperature Analog parameter. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) |
|
rxlabelFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.13 |
The value of this object provides the label of the
Fan Current Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxuomFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.14 |
The value of this object provides the Unit of Measure of the
Fan Current Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxmajorHighFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.15 |
The value of this object provides the Major High alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxmajorLowFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.16 |
The value of this object provides the Major Low alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxminorHighFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.17 |
The value of this object provides the Minor High alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxminorLowFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.18 |
The value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxcurrentValueFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.19 |
The value of this object provides the Current value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxstateFlagFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.20 |
The value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxminValueFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.21 |
The value of this object provides the minimum value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxmaxValueFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.22 |
The value of this object provides the maximum value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxalarmStateFanCurrent |
1.3.6.1.4.1.1166.6.1.2.6.2.1.23 |
The value of this object provides the curent alarm state of
the Fan Current Analog parameter. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) |
|
rxlabel12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.24 |
The value of this object provides the label of the
12v Current Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxuom12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.25 |
The value of this object provides the Unit of Measure of the
12v Current Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxmajorHigh12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.26 |
The value of this object provides the Major High alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxmajorLow12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.27 |
The value of this object provides the Major Low alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxminorHigh12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.28 |
The value of this object provides the Minor High alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxminorLow12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.29 |
The value of this object provides the Minor Low alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxcurrentValue12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.30 |
The value of this object provides the Current value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxstateFlag12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.31 |
The value of this object provides the state
of the 12v Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxminValue12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.32 |
The value of this object provides the minimum value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxmaxValue12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.33 |
The value of this object provides the maximum value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxalarmState12Volt |
1.3.6.1.4.1.1166.6.1.2.6.2.1.34 |
The value of this object provides the curent alarm state of
the 12v Current Analog parameter. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) |
|
rxlabelOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.35 |
The value of this object provides the label of the
Optical Power Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxuomOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.36 |
The value of this object provides the Unit of Measure of the
Optical Power Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxmajorHighOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.37 |
The value of this object provides the Major High alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxmajorLowOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.38 |
The value of this object provides the Major Low alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxminorHighOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.39 |
The value of this object provides the Minor High alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxminorLowOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.40 |
The value of this object provides the Minor Low alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxcurrentValueOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.41 |
The value of this object provides the Current value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxstateFlagOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.42 |
The value of this object provides the state
of the Optical Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxminValueOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.43 |
The value of this object provides the minimum value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxmaxValueOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.44 |
The value of this object provides the maximum value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
rxalarmStateOptPower |
1.3.6.1.4.1.1166.6.1.2.6.2.1.45 |
The value of this object provides the curent alarm state of
the Optical Power Analog parameter. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) |
|
rxgx2Rx200DigitalTableIndex |
1.3.6.1.4.1.1166.6.1.2.6.3.2.1 |
The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..4294967295 |
|
rxlabelMode |
1.3.6.1.4.1.1166.6.1.2.6.3.2.2 |
The value of this object provides the label of the
RX200's Mode Digital parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxenumMode |
1.3.6.1.4.1.1166.6.1.2.6.3.2.3 |
The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueMode |
1.3.6.1.4.1.1166.6.1.2.6.3.2.4 |
The value of this object is the current value of the parameter. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), normal(2), burst(3) |
|
rxstateFlagMode |
1.3.6.1.4.1.1166.6.1.2.6.3.2.5 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelWavelength |
1.3.6.1.4.1.1166.6.1.2.6.3.2.6 |
The value of this object provides the label of the
RX200's Wavelength Digital parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxenumWavelength |
1.3.6.1.4.1.1166.6.1.2.6.3.2.7 |
The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueWavelength |
1.3.6.1.4.1.1166.6.1.2.6.3.2.8 |
The value of this object is the current value of the parameter. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
nM1310(1), nM1550(2) |
|
rxstateFlagWavelength |
1.3.6.1.4.1.1166.6.1.2.6.3.2.9 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelAttnSetting |
1.3.6.1.4.1.1166.6.1.2.6.3.2.10 |
The value of this object provides the label of the
RX200's AttnSetting Digital parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxenumAttnSetting |
1.3.6.1.4.1.1166.6.1.2.6.3.2.11 |
The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueAttnSetting |
1.3.6.1.4.1.1166.6.1.2.6.3.2.12 |
The value of this object is the current value of the parameter. It is an integer
value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB.
Where 0 = 0db and 40 = 20db |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxstateFlagAttnSetting |
1.3.6.1.4.1.1166.6.1.2.6.3.2.13 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelSwModeSetting |
1.3.6.1.4.1.1166.6.1.2.6.3.2.14 |
The value of this object provides the label of the
RX200's Switch Mode Setting Digital parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxenumSwModeSetting |
1.3.6.1.4.1.1166.6.1.2.6.3.2.15 |
The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueSwModeSetting |
1.3.6.1.4.1.1166.6.1.2.6.3.2.16 |
The value of this object is the current value of the parameter. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), alarm-only(2), alarm-and-switch(3) |
|
rxstateFlagSwModeSetting |
1.3.6.1.4.1.1166.6.1.2.6.3.2.17 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelSwModeThreshold |
1.3.6.1.4.1.1166.6.1.2.6.3.2.18 |
The value of this object provides the label of the
RX200's Switch Mode Threshold Digital parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxenumSwModeThreshold |
1.3.6.1.4.1.1166.6.1.2.6.3.2.19 |
The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueSwModeThreshold |
1.3.6.1.4.1.1166.6.1.2.6.3.2.20 |
The value of this object reflects the setting of the threshold at
which the Optical Input Failed signal is sent. It is in 1 dB increments
ranging from -2 to -17 dB. The user can enter a number from 0 to 15,
where 0 = -2db and 15= -17db |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxstateFlagSwModeThreshold |
1.3.6.1.4.1.1166.6.1.2.6.3.2.21 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelFactoryDefault |
1.3.6.1.4.1.1166.6.1.2.6.3.2.22 |
The value of this object provides the label of the
Factory Default Reset Digital parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxenumFactoryDefault |
1.3.6.1.4.1.1166.6.1.2.6.3.2.23 |
The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueFactoryDefault |
1.3.6.1.4.1.1166.6.1.2.6.3.2.24 |
The value of this object is the current value of the parameter. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
rxstateFlagFactoryDefault |
1.3.6.1.4.1.1166.6.1.2.6.3.2.25 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxgx2Rx200StatusTableIndex |
1.3.6.1.4.1.1166.6.1.2.6.4.3.1 |
The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..4294967295 |
|
rxlabelBoot |
1.3.6.1.4.1.1166.6.1.2.6.4.3.2 |
The value of this object provides the label of the
Boot Status Status parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueBoot |
1.3.6.1.4.1.1166.6.1.2.6.4.3.3 |
The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) |
|
rxstateflagBoot |
1.3.6.1.4.1.1166.6.1.2.6.4.3.4 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelFlash |
1.3.6.1.4.1.1166.6.1.2.6.4.3.5 |
The value of this object provides the label of the
Flash Status Status parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueFlash |
1.3.6.1.4.1.1166.6.1.2.6.4.3.6 |
The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) |
|
rxstateflagFlash |
1.3.6.1.4.1.1166.6.1.2.6.4.3.7 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelFactoryDataCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.8 |
The value of this object provides the label of the
Factory Data CRC Status parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueFactoryDataCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.9 |
The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) |
|
rxstateflagFactoryDataCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.10 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelAlarmDataCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.11 |
The value of this object provides the label of the
Alarm Data CRC Status parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueAlarmDataCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.12 |
The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) |
|
rxstateflagAlarmDataCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.13 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelCalibrationDataCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.14 |
The value of this object provides the label of the
Calibration Data CRC Status parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueCalibrationDataCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.15 |
The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) |
|
rxstateflagCalibrationDataCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.16 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelThermalCompCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.17 |
The value of this object provides the label of the
Calibration Data CRC Status parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueThermalCompCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.18 |
The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) |
|
rxstateflagThermalCompCRC |
1.3.6.1.4.1.1166.6.1.2.6.4.3.19 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelHW |
1.3.6.1.4.1.1166.6.1.2.6.4.3.20 |
The value of this object provides the label of the
Hardware Status parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueHW |
1.3.6.1.4.1.1166.6.1.2.6.4.3.21 |
The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) |
|
rxstateflagHW |
1.3.6.1.4.1.1166.6.1.2.6.4.3.22 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxlabelOptSig |
1.3.6.1.4.1.1166.6.1.2.6.4.3.23 |
The value of this object provides the label of the
Optical Signal Status parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxvalueOptSig |
1.3.6.1.4.1.1166.6.1.2.6.4.3.24 |
The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) |
|
rxstateflagOptSig |
1.3.6.1.4.1.1166.6.1.2.6.4.3.25 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
rxgx2Rx200FactoryTableIndex |
1.3.6.1.4.1.1166.6.1.2.6.5.4.1 |
The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..4294967295 |
|
rxbootControlByte |
1.3.6.1.4.1.1166.6.1.2.6.5.4.2 |
The value of this object indicates which bank the firmware
is currently being boot from. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxbootStatusByte |
1.3.6.1.4.1.1166.6.1.2.6.5.4.3 |
This object indicates the status of the last boot |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxbank0CRC |
1.3.6.1.4.1.1166.6.1.2.6.5.4.4 |
This object provides the CRC code of bank 0. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxbank1CRC |
1.3.6.1.4.1.1166.6.1.2.6.5.4.5 |
This object provides the CRC code of bank 1. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxprgEEPROMByte |
1.3.6.1.4.1.1166.6.1.2.6.5.4.6 |
This object indicates if the EEPROM has been programmed |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxfactoryCRC |
1.3.6.1.4.1.1166.6.1.2.6.5.4.7 |
This object provides the CRC code for the Factory data. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxcalculateCRC |
1.3.6.1.4.1.1166.6.1.2.6.5.4.8 |
This object indicates which of the Emnums will have the CRC calculated. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
factory(1), calibration(2), alarm(3), tempComp(4) |
|
rxhourMeter |
1.3.6.1.4.1.1166.6.1.2.6.5.4.9 |
This object provides the hour meter reading of the module. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxflashPrgCntA |
1.3.6.1.4.1.1166.6.1.2.6.5.4.10 |
This object provides the number of times the flash has been
programmed on side A. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxflashPrgCntB |
1.3.6.1.4.1.1166.6.1.2.6.5.4.11 |
This object provides the number of times the flash has been
programmed on side B. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxfwRev0 |
1.3.6.1.4.1.1166.6.1.2.6.5.4.12 |
This object provides the Revision of the firmware stores in bank 0. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxfwRev1 |
1.3.6.1.4.1.1166.6.1.2.6.5.4.13 |
This object provides the Revision of the firmware stores in bank 1. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
rxgx2Rx200HoldTimeSpecIndex |
1.3.6.1.4.1.1166.6.1.2.6.6.5.2 |
The value of this object identifies the index of the alarm object to be modified. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..4294967295 |
|
rxgx2Rx200HoldTimeData |
1.3.6.1.4.1.1166.6.1.2.6.6.5.3 |
The value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trapRX200ConfigChangeInteger |
1 |
This trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' |
TRAP-TYPE |
|
|
|
trapRX200ConfigChangeDisplayString |
2 |
This trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' |
TRAP-TYPE |
|
|
|
trapRX200OpticalPowerAlarm |
3 |
This trap is issued when the Laser Modules Optical Power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200ModuleTemperatureAlarm |
4 |
This trap is issued when the RX200 Modules Temperature goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200FanCurrentAlarm |
5 |
This trap is issued when the RX200 Modules Fan Currrent parameter
goes out of range. trapAdditionalInfoInteger variable contains current reading of
the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200Plus12CurrentAlarm |
6 |
This trap is issued when the RX200 Modules positive 12 volt current parameter
goes out of range. trapAdditionalInfoInteger variable contains current reading of
the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200Boot0Alarm |
7 |
This trap is issued when the RX200 Modules Bank 0 Boot sequence has detected an error.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200Boot1Alarm |
8 |
This trap is issued when the RX200 Modules Bank 1 Boot sequence has detected an error.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200FlashAlarm |
9 |
This trap is issued when the RX200 Modules boot or flash programming sequence has
detected a Flash error. trapAdditionalInfoInteger variable contains current reading of
the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200AlarmDataCRCAlarm |
10 |
This trap is issued when the RX200 Module detects an error calculating the alarm limit CRC.
trapAdditionalInfoInteger variable contains current reading of the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200FactoryDataCRCAlarm |
11 |
This trap is issued when the RX200 Module detects an error calculating the Factory data CRC.
trapAdditionalInfoInteger variable contains current reading of the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200CalDataCRCAlarm |
12 |
This trap is issued when the RX200 Module detects an error calculating the Calibration data CRC.
trapAdditionalInfoInteger variable contains current reading of the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200DefaultAlarm |
13 |
This trap is issued when the RX200 Module is reset to it's factory default state.
trapAdditionalInfoInteger variable contains current reading of the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200ModeAlarm |
14 |
This trap is issued when the RX200 Modules mode is changed from normal to off or off to normal.
trapAdditionalInfoInteger variable contains current reading of the this parameter. |
TRAP-TYPE |
|
|
|
trapRX200OutputSwitchedAlarm |
15 |
This trap is issued when the RX200 Module's output to the RF Switch Module changes state
from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading
of the this parameter. |
TRAP-TYPE |
|
|
|