OMNI-gx2RX200-MIB

File: OMNI-gx2RX200-MIB.mib (69235 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Rx200 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

U32Data  
Counter    

Gx2Rx200AnalogEntry  
SEQUENCE    
  rxgx2Rx200AnalogTableIndex INTEGER
  rxlabelModTemp DisplayString Size(0..80)
  rxuomModTemp DisplayString Size(0..80)
  rxmajorHighModTemp Float
  rxmajorLowModTemp Float
  rxminorHighModTemp Float
  rxminorLowModTemp Float
  rxcurrentValueModTemp Float
  rxstateFlagModTemp INTEGER
  rxminValueModTemp Float
  rxmaxValueModTemp Float
  rxalarmStateModTemp INTEGER
  rxlabelFanCurrent DisplayString Size(0..80)
  rxuomFanCurrent DisplayString Size(0..80)
  rxmajorHighFanCurrent Float
  rxmajorLowFanCurrent Float
  rxminorHighFanCurrent Float
  rxminorLowFanCurrent Float
  rxcurrentValueFanCurrent Float
  rxstateFlagFanCurrent INTEGER
  rxminValueFanCurrent Float
  rxmaxValueFanCurrent Float
  rxalarmStateFanCurrent INTEGER
  rxlabel12Volt DisplayString Size(0..80)
  rxuom12Volt DisplayString Size(0..80)
  rxmajorHigh12Volt Float
  rxmajorLow12Volt Float
  rxminorHigh12Volt Float
  rxminorLow12Volt Float
  rxcurrentValue12Volt Float
  rxstateFlag12Volt INTEGER
  rxminValue12Volt Float
  rxmaxValue12Volt Float
  rxalarmState12Volt INTEGER
  rxlabelOptPower DisplayString Size(0..80)
  rxuomOptPower DisplayString Size(0..80)
  rxmajorHighOptPower Float
  rxmajorLowOptPower Float
  rxminorHighOptPower Float
  rxminorLowOptPower Float
  rxcurrentValueOptPower Float
  rxstateFlagOptPower INTEGER
  rxminValueOptPower Float
  rxmaxValueOptPower Float
  rxalarmStateOptPower INTEGER

Gx2Rx200DigitalEntry  
SEQUENCE    
  rxgx2Rx200DigitalTableIndex INTEGER
  rxlabelMode DisplayString Size(0..80)
  rxvalueMode INTEGER
  rxenumMode DisplayString Size(0..80)
  rxstateFlagMode INTEGER
  rxlabelWavelength DisplayString Size(0..80)
  rxvalueWavelength INTEGER
  rxenumWavelength DisplayString Size(0..80)
  rxstateFlagWavelength INTEGER
  rxlabelAttnSetting DisplayString Size(0..80)
  rxvalueAttnSetting INTEGER
  rxenumAttnSetting DisplayString Size(0..80)
  rxstateFlagAttnSetting INTEGER
  rxlabelSwModeSetting DisplayString Size(0..80)
  rxvalueSwModeSetting INTEGER
  rxenumSwModeSetting DisplayString Size(0..80)
  rxstateFlagSwModeSetting INTEGER
  rxlabelSwModeThreshold DisplayString Size(0..80)
  rxvalueSwModeThreshold INTEGER
  rxenumSwModeThreshold DisplayString Size(0..80)
  rxstateFlagSwModeThreshold INTEGER
  rxlabelFactoryDefault DisplayString Size(0..80)
  rxvalueFactoryDefault INTEGER
  rxenumFactoryDefault DisplayString Size(0..80)
  rxstateFlagFactoryDefault INTEGER

Gx2Rx200StatusEntry  
SEQUENCE    
  rxgx2Rx200StatusTableIndex INTEGER
  rxlabelBoot DisplayString Size(0..80)
  rxvalueBoot INTEGER
  rxstateflagBoot INTEGER
  rxlabelFlash DisplayString Size(0..80)
  rxvalueFlash INTEGER
  rxstateflagFlash INTEGER
  rxlabelFactoryDataCRC DisplayString Size(0..80)
  rxvalueFactoryDataCRC INTEGER
  rxstateflagFactoryDataCRC INTEGER
  rxlabelAlarmDataCRC DisplayString Size(0..80)
  rxvalueAlarmDataCRC INTEGER
  rxstateflagAlarmDataCRC INTEGER
  rxlabelCalibrationDataCRC DisplayString Size(0..80)
  rxvalueCalibrationDataCRC INTEGER
  rxstateflagCalibrationDataCRC INTEGER
  rxlabelThermalCompCRC DisplayString Size(0..80)
  rxvalueThermalCompCRC INTEGER
  rxstateflagThermalCompCRC INTEGER
  rxlabelHW DisplayString Size(0..80)
  rxvalueHW INTEGER
  rxstateflagHW INTEGER
  rxlabelOptSig DisplayString Size(0..80)
  rxvalueOptSig INTEGER
  rxstateflagOptSig INTEGER

Gx2Rx200FactoryEntry  
SEQUENCE    
  rxgx2Rx200FactoryTableIndex INTEGER
  rxbootControlByte INTEGER
  rxbootStatusByte INTEGER
  rxbank0CRC INTEGER
  rxbank1CRC INTEGER
  rxprgEEPROMByte INTEGER
  rxfactoryCRC INTEGER
  rxcalculateCRC INTEGER
  rxhourMeter INTEGER
  rxflashPrgCntA INTEGER
  rxflashPrgCntB INTEGER
  rxfwRev0 DisplayString Size(0..80)
  rxfwRev1 DisplayString Size(0..80)

Gx2Rx200HoldTimeEntry  
SEQUENCE    
  rxgx2Rx200HoldTimeTableIndex INTEGER
  rxgx2Rx200HoldTimeSpecIndex INTEGER
  rxgx2Rx200HoldTimeData INTEGER

Defined Values

gx2Rx200Descriptor 1.3.6.1.4.1.1166.6.1.2.6.1
OBJECT IDENTIFIER    

gx2Rx200AnalogTable 1.3.6.1.4.1.1166.6.1.2.6.2
This table contains gx2Rx200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx200AnalogEntry

gx2Rx200AnalogEntry 1.3.6.1.4.1.1166.6.1.2.6.2.1
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx200AnalogEntry  

gx2Rx200DigitalTable 1.3.6.1.4.1.1166.6.1.2.6.3
This table contains gx2Rx200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx200DigitalEntry

gx2Rx200DigitalEntry 1.3.6.1.4.1.1166.6.1.2.6.3.2
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx200DigitalEntry  

gx2Rx200StatusTable 1.3.6.1.4.1.1166.6.1.2.6.4
This table contains gx2Rx200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx200StatusEntry

gx2Rx200StatusEntry 1.3.6.1.4.1.1166.6.1.2.6.4.3
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx200StatusEntry  

gx2Rx200FactoryTable 1.3.6.1.4.1.1166.6.1.2.6.5
This table contains gx2Rx200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx200FactoryEntry

gx2Rx200FactoryEntry 1.3.6.1.4.1.1166.6.1.2.6.5.4
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx200FactoryEntry  

gx2Rx200HoldTimeTable 1.3.6.1.4.1.1166.6.1.2.6.6
This table contains gx2Rx200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx200HoldTimeEntry

gx2Rx200HoldTimeEntry 1.3.6.1.4.1.1166.6.1.2.6.6.5
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx200HoldTimeEntry  

rxgx2Rx200AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.6.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rxlabelModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.2
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxuomModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.3
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxmajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.4
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxmajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.5
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.6
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.7
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxcurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.8
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxstateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.9
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxminValueModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.10
The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxmaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.11
The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxalarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.6.2.1.12
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rxlabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.13
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxuomFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.14
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxmajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.15
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxmajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.16
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.17
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.18
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxcurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.19
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxstateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.20
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.21
The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxmaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.22
The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxalarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.6.2.1.23
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rxlabel12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.24
The value of this object provides the label of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxuom12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.25
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxmajorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.26
The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxmajorLow12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.27
The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxminorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.28
The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxminorLow12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.29
The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxcurrentValue12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.30
The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxstateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.31
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxminValue12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.32
The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxmaxValue12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.33
The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxalarmState12Volt 1.3.6.1.4.1.1166.6.1.2.6.2.1.34
The value of this object provides the curent alarm state of the 12v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rxlabelOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.35
The value of this object provides the label of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxuomOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.36
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxmajorHighOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.37
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxmajorLowOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.38
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxminorHighOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.39
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxminorLowOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.40
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxcurrentValueOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.41
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxstateFlagOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.42
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxminValueOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.43
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxmaxValueOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.44
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rxalarmStateOptPower 1.3.6.1.4.1.1166.6.1.2.6.2.1.45
The value of this object provides the curent alarm state of the Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rxgx2Rx200DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.6.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rxlabelMode 1.3.6.1.4.1.1166.6.1.2.6.3.2.2
The value of this object provides the label of the RX200's Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxenumMode 1.3.6.1.4.1.1166.6.1.2.6.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueMode 1.3.6.1.4.1.1166.6.1.2.6.3.2.4
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), normal(2), burst(3)  

rxstateFlagMode 1.3.6.1.4.1.1166.6.1.2.6.3.2.5
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelWavelength 1.3.6.1.4.1.1166.6.1.2.6.3.2.6
The value of this object provides the label of the RX200's Wavelength Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxenumWavelength 1.3.6.1.4.1.1166.6.1.2.6.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueWavelength 1.3.6.1.4.1.1166.6.1.2.6.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nM1310(1), nM1550(2)  

rxstateFlagWavelength 1.3.6.1.4.1.1166.6.1.2.6.3.2.9
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelAttnSetting 1.3.6.1.4.1.1166.6.1.2.6.3.2.10
The value of this object provides the label of the RX200's AttnSetting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxenumAttnSetting 1.3.6.1.4.1.1166.6.1.2.6.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueAttnSetting 1.3.6.1.4.1.1166.6.1.2.6.3.2.12
The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rxstateFlagAttnSetting 1.3.6.1.4.1.1166.6.1.2.6.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelSwModeSetting 1.3.6.1.4.1.1166.6.1.2.6.3.2.14
The value of this object provides the label of the RX200's Switch Mode Setting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxenumSwModeSetting 1.3.6.1.4.1.1166.6.1.2.6.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueSwModeSetting 1.3.6.1.4.1.1166.6.1.2.6.3.2.16
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), alarm-only(2), alarm-and-switch(3)  

rxstateFlagSwModeSetting 1.3.6.1.4.1.1166.6.1.2.6.3.2.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelSwModeThreshold 1.3.6.1.4.1.1166.6.1.2.6.3.2.18
The value of this object provides the label of the RX200's Switch Mode Threshold Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxenumSwModeThreshold 1.3.6.1.4.1.1166.6.1.2.6.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueSwModeThreshold 1.3.6.1.4.1.1166.6.1.2.6.3.2.20
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rxstateFlagSwModeThreshold 1.3.6.1.4.1.1166.6.1.2.6.3.2.21
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.6.3.2.22
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxenumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.6.3.2.23
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.6.3.2.24
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

rxstateFlagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.6.3.2.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxgx2Rx200StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.6.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rxlabelBoot 1.3.6.1.4.1.1166.6.1.2.6.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueBoot 1.3.6.1.4.1.1166.6.1.2.6.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rxstateflagBoot 1.3.6.1.4.1.1166.6.1.2.6.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelFlash 1.3.6.1.4.1.1166.6.1.2.6.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueFlash 1.3.6.1.4.1.1166.6.1.2.6.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rxstateflagFlash 1.3.6.1.4.1.1166.6.1.2.6.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rxstateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.11
The value of this object provides the label of the Alarm Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rxstateflagAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.14
The value of this object provides the label of the Calibration Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rxstateflagCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelThermalCompCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.17
The value of this object provides the label of the Calibration Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueThermalCompCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rxstateflagThermalCompCRC 1.3.6.1.4.1.1166.6.1.2.6.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelHW 1.3.6.1.4.1.1166.6.1.2.6.4.3.20
The value of this object provides the label of the Hardware Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueHW 1.3.6.1.4.1.1166.6.1.2.6.4.3.21
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rxstateflagHW 1.3.6.1.4.1.1166.6.1.2.6.4.3.22
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxlabelOptSig 1.3.6.1.4.1.1166.6.1.2.6.4.3.23
The value of this object provides the label of the Optical Signal Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxvalueOptSig 1.3.6.1.4.1.1166.6.1.2.6.4.3.24
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rxstateflagOptSig 1.3.6.1.4.1.1166.6.1.2.6.4.3.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rxgx2Rx200FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.6.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rxbootControlByte 1.3.6.1.4.1.1166.6.1.2.6.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxbootStatusByte 1.3.6.1.4.1.1166.6.1.2.6.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxbank0CRC 1.3.6.1.4.1.1166.6.1.2.6.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxbank1CRC 1.3.6.1.4.1.1166.6.1.2.6.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.6.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxfactoryCRC 1.3.6.1.4.1.1166.6.1.2.6.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxcalculateCRC 1.3.6.1.4.1.1166.6.1.2.6.5.4.8
This object indicates which of the Emnums will have the CRC calculated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), calibration(2), alarm(3), tempComp(4)  

rxhourMeter 1.3.6.1.4.1.1166.6.1.2.6.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxflashPrgCntA 1.3.6.1.4.1.1166.6.1.2.6.5.4.10
This object provides the number of times the flash has been programmed on side A.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxflashPrgCntB 1.3.6.1.4.1.1166.6.1.2.6.5.4.11
This object provides the number of times the flash has been programmed on side B.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxfwRev0 1.3.6.1.4.1.1166.6.1.2.6.5.4.12
This object provides the Revision of the firmware stores in bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxfwRev1 1.3.6.1.4.1.1166.6.1.2.6.5.4.13
This object provides the Revision of the firmware stores in bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxgx2Rx200HoldTimeTableIndex 1.3.6.1.4.1.1166.6.1.2.6.6.5.1
The value of this object is the index of the data object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rxgx2Rx200HoldTimeSpecIndex 1.3.6.1.4.1.1166.6.1.2.6.6.5.2
The value of this object identifies the index of the alarm object to be modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rxgx2Rx200HoldTimeData 1.3.6.1.4.1.1166.6.1.2.6.6.5.3
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

trapRX200ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapRX200ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapRX200OpticalPowerAlarm 3
This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200ModuleTemperatureAlarm 4
This trap is issued when the RX200 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200FanCurrentAlarm 5
This trap is issued when the RX200 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200Plus12CurrentAlarm 6
This trap is issued when the RX200 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200Boot0Alarm 7
This trap is issued when the RX200 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200Boot1Alarm 8
This trap is issued when the RX200 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200FlashAlarm 9
This trap is issued when the RX200 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200AlarmDataCRCAlarm 10
This trap is issued when the RX200 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200FactoryDataCRCAlarm 11
This trap is issued when the RX200 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200CalDataCRCAlarm 12
This trap is issued when the RX200 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200DefaultAlarm 13
This trap is issued when the RX200 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200ModeAlarm 14
This trap is issued when the RX200 Modules mode is changed from normal to off or off to normal. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200OutputSwitchedAlarm 15
This trap is issued when the RX200 Module's output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRX200SideStatusAlarm 16
This trap is issued when one of the RX200 Module's outputs are turned on or off.
TRAP-TYPE