OMNI-gx2RX1000-MIB

File: OMNI-gx2RX1000-MIB.mib (70975 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Rx1000 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2Rx1000AnalogEntry  
SEQUENCE    
  fprgx2Rx1000AnalogTableIndex INTEGER
  fprlabelOptPower DisplayString Size(0..80)
  fpruomOptPower DisplayString Size(0..80)
  fprmajorHighOptPower Float
  fprmajorLowOptPower Float
  fprminorHighOptPower Float
  fprminorLowOptPower Float
  fprcurrentValueOptPower Float
  fprstateFlagOptPower INTEGER
  fprminValueOptPower Float
  fprmaxValueOptPower Float
  fpralarmStateOptPower INTEGER
  fprlabelModTemp DisplayString Size(0..80)
  fpruomModTemp DisplayString Size(0..80)
  fprmajorHighModTemp Float
  fprmajorLowModTemp Float
  fprminorHighModTemp Float
  fprminorLowModTemp Float
  fprcurrentValueModTemp Float
  fprstateFlagModTemp INTEGER
  fprminValueModTemp Float
  fprmaxValueModTemp Float
  fpralarmStateModTemp INTEGER
  fprlabelSinkTemp DisplayString Size(0..80)
  fpruomSinkTemp DisplayString Size(0..80)
  fprmajorHighSinkTemp Float
  fprmajorLowSinkTemp Float
  fprminorHighSinkTemp Float
  fprminorLowSinkTemp Float
  fprcurrentValueSinkTemp Float
  fprstateFlagSinkTemp INTEGER
  fprminValueSinkTemp Float
  fprmaxValueSinkTemp Float
  fpralarmStateSinkTemp INTEGER
  fprlabelFanCurrent DisplayString Size(0..80)
  fpruomFanCurrent DisplayString Size(0..80)
  fprmajorHighFanCurrent Float
  fprmajorLowFanCurrent Float
  fprminorHighFanCurrent Float
  fprminorLowFanCurrent Float
  fprcurrentValueFanCurrent Float
  fprstateFlagFanCurrent INTEGER
  fprminValueFanCurrent Float
  fprmaxValueFanCurrent Float
  fpralarmStateFanCurrent INTEGER
  fprlabel12Volt DisplayString Size(0..80)
  fpruom12Volt DisplayString Size(0..80)
  fprmajorHigh12Volt Float
  fprmajorLow12Volt Float
  fprminorHigh12Volt Float
  fprminorLow12Volt Float
  fprcurrentValue12Volt Float
  fprstateFlag12Volt INTEGER
  fprminValue12Volt Float
  fprmaxValue12Volt Float
  fpralarmState12Volt INTEGER

Gx2Rx1000DigitalEntry  
SEQUENCE    
  fprgx2Rx1000DigitalTableIndex INTEGER
  fprlabelSlopeSetting DisplayString Size(0..80)
  fprvalueSlopeSetting INTEGER
  fprenumSlopeSetting DisplayString Size(0..80)
  fprstateFlagSlopeSetting INTEGER
  fprlabelAttnSetting DisplayString Size(0..80)
  fprvalueAttnSetting INTEGER
  fprenumAttnSetting DisplayString Size(0..80)
  fprstateFlagAttnSetting INTEGER
  fprlabelWavelength DisplayString Size(0..80)
  fprvalueWavelength INTEGER
  fprenumWavelength DisplayString Size(0..80)
  fprstateFlagWavelength INTEGER
  fprlabelFactoryDefault DisplayString Size(0..80)
  fprvalueFactoryDefault INTEGER
  fprenumFactoryDefault DisplayString Size(0..80)
  fprstateFlagFactoryDefault INTEGER
  fprlabelSwModeThreshold DisplayString Size(0..80)
  fprvalueSwModeThreshold INTEGER
  fprenumSwModeThreshold DisplayString Size(0..80)
  fprstateFlagSwModeThreshold INTEGER
  fprlabelSwModeSetting DisplayString Size(0..80)
  fprvalueSwModeSetting INTEGER
  fprenumSwModeSetting DisplayString Size(0..80)
  fprstateFlagSwModeSetting INTEGER

Gx2Rx1000StatusEntry  
SEQUENCE    
  fprgx2Rx1000StatusTableIndex INTEGER
  fprlabelBoot DisplayString Size(0..80)
  fprvalueBoot INTEGER
  fprstateflagBoot INTEGER
  fprlabelFlash DisplayString Size(0..80)
  fprvalueFlash INTEGER
  fprstateflagFlash INTEGER
  fprlabelFactoryDataCRC DisplayString Size(0..80)
  fprvalueFactoryDataCRC INTEGER
  fprstateflagFactoryDataCRC INTEGER
  fprlabelAlarmDataCRC DisplayString Size(0..80)
  fprvalueAlarmDataCRC INTEGER
  fprstateflagAlarmDataCRC INTEGER
  fprlabelCalibrationDataCRC DisplayString Size(0..80)
  fprvalueCalibrationDataCRC INTEGER
  fprstateflagCalibrationDataCRC INTEGER
  fprlabelFacCalSettingCRC DisplayString Size(0..80)
  fprvalueFacCalSettingCRC INTEGER
  fprstateflagFacCalSettingCRC INTEGER
  fprlabelInputSig DisplayString Size(0..80)
  fprvalueInputSig INTEGER
  fprstateflagInputSig INTEGER

Gx2Rx1000FactoryEntry  
SEQUENCE    
  fprgx2Rx1000FactoryTableIndex INTEGER
  fprbootControlByte INTEGER
  fprbootStatusByte INTEGER
  fprbank0CRC INTEGER
  fprbank1CRC INTEGER
  fprprgEEPROMByte INTEGER
  fprfactoryCRC INTEGER
  fprcalculateCRC INTEGER
  fprhourMeter INTEGER
  fprflashPrgCntA INTEGER
  fprflashPrgCntB INTEGER
  fprfwRev0 DisplayString Size(0..80)
  fprfwRev1 DisplayString Size(0..80)

Gx2Rx1000HoldTimeEntry  
SEQUENCE    
  gx2Rx1000HoldTimeTableIndex INTEGER
  gx2Rx1000HoldTimeSpecIndex INTEGER
  gx2Rx1000HoldTimeData INTEGER

Defined Values

gx2Rx1000Descriptor 1.3.6.1.4.1.1166.6.1.2.9.1
OBJECT IDENTIFIER    

gx2Rx1000AnalogTable 1.3.6.1.4.1.1166.6.1.2.9.2
This table contains gx2Rx1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx1000AnalogEntry

gx2Rx1000AnalogEntry 1.3.6.1.4.1.1166.6.1.2.9.2.1
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx1000AnalogEntry  

gx2Rx1000DigitalTable 1.3.6.1.4.1.1166.6.1.2.9.3
This table contains gx2Rx1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx1000DigitalEntry

gx2Rx1000DigitalEntry 1.3.6.1.4.1.1166.6.1.2.9.3.2
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx1000DigitalEntry  

gx2Rx1000StatusTable 1.3.6.1.4.1.1166.6.1.2.9.4
This table contains gx2Rx1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx1000StatusEntry

gx2Rx1000StatusEntry 1.3.6.1.4.1.1166.6.1.2.9.4.3
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx1000StatusEntry  

gx2Rx1000FactoryTable 1.3.6.1.4.1.1166.6.1.2.9.5
This table contains gx2Rx1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx1000FactoryEntry

gx2Rx1000FactoryEntry 1.3.6.1.4.1.1166.6.1.2.9.5.4
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx1000FactoryEntry  

gx2Rx1000HoldTimeTable 1.3.6.1.4.1.1166.6.1.2.9.6
This table contains gx2Rx1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx1000HoldTimeEntry

gx2Rx1000HoldTimeEntry 1.3.6.1.4.1.1166.6.1.2.9.6.5
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx1000HoldTimeEntry  

fprgx2Rx1000AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.9.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

fprlabelOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.2
The value of this object provides the label of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fpruomOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.3
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprmajorHighOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.4
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprmajorLowOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.5
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprminorHighOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.6
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprminorLowOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.7
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprcurrentValueOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.8
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprstateFlagOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.9
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprminValueOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.10
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprmaxValueOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.11
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fpralarmStateOptPower 1.3.6.1.4.1.1166.6.1.2.9.2.1.12
The value of this object provides the curent alarm state of the Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

fprlabelModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.13
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fpruomModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.14
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprmajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.15
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprmajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.16
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.17
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.18
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprcurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.19
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprstateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.20
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprminValueModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.21
The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprmaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.22
The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fpralarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.23
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

fprlabelSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.24
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fpruomSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.25
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprmajorHighSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.26
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprmajorLowSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.27
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprminorHighSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.28
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprminorLowSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.29
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprcurrentValueSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.30
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprstateFlagSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.31
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprminValueSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.32
The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprmaxValueSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.33
The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fpralarmStateSinkTemp 1.3.6.1.4.1.1166.6.1.2.9.2.1.34
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

fprlabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.35
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fpruomFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.36
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprmajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.37
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprmajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.38
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.39
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.40
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprcurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.41
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprstateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.42
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.43
The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprmaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.44
The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fpralarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.9.2.1.45
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

fprlabel12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.46
The value of this object provides the label of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fpruom12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.47
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprmajorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.48
The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprmajorLow12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.49
The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprminorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.50
The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprminorLow12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.51
The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprcurrentValue12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.52
The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprstateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.53
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprminValue12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.54
The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fprmaxValue12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.55
The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

fpralarmState12Volt 1.3.6.1.4.1.1166.6.1.2.9.2.1.56
The value of this object provides the curent alarm state of the 12v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

fprgx2Rx1000DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.9.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

fprlabelSlopeSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.2
The value of this object provides the label of the RX1000's AttnSetting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprenumSlopeSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueSlopeSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.4
The value of this object is the current value of the parameter. It is an integer value from 0 to 6. Each increment represents 1/2 dB of slope from 0 to 3 dB. Where 0 = 0db and 6 = 3db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fprstateFlagSlopeSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.5
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelAttnSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.6
The value of this object provides the label of the RX1000's AttnSetting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprenumAttnSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueAttnSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.8
The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/4 dB of attenuation from 0 to 10 dB. Where 0 = 0db and 40 = 10db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fprstateFlagAttnSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.9
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelWavelength 1.3.6.1.4.1.1166.6.1.2.9.3.2.10
The value of this object provides the label of the RX1000's Wavelength Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprenumWavelength 1.3.6.1.4.1.1166.6.1.2.9.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value has a enumerated value of 0.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueWavelength 1.3.6.1.4.1.1166.6.1.2.9.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nM1310(1), nM1550(2)  

fprstateFlagWavelength 1.3.6.1.4.1.1166.6.1.2.9.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.9.3.2.14
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprenumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.9.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.9.3.2.16
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fprstateFlagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.9.3.2.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelSwModeThreshold 1.3.6.1.4.1.1166.6.1.2.9.3.2.18
The value of this object provides the label of the RX1000's Switch Mode Threshold Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprenumSwModeThreshold 1.3.6.1.4.1.1166.6.1.2.9.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value has a enumerated value of 0.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueSwModeThreshold 1.3.6.1.4.1.1166.6.1.2.9.3.2.20
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 0.5 dB increments ranging from -9 to +1 dB. The user can enter a number from 0 to 20, where 0 = -9db and 20= +1db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fprstateFlagSwModeThreshold 1.3.6.1.4.1.1166.6.1.2.9.3.2.21
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelSwModeSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.22
The value of this object provides the label of the RX1000's Switch Mode Setting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprenumSwModeSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.23
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueSwModeSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.24
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), alarm-only(2), alarm-and-switch(3)  

fprstateFlagSwModeSetting 1.3.6.1.4.1.1166.6.1.2.9.3.2.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprgx2Rx1000StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.9.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

fprlabelBoot 1.3.6.1.4.1.1166.6.1.2.9.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueBoot 1.3.6.1.4.1.1166.6.1.2.9.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

fprstateflagBoot 1.3.6.1.4.1.1166.6.1.2.9.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelFlash 1.3.6.1.4.1.1166.6.1.2.9.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueFlash 1.3.6.1.4.1.1166.6.1.2.9.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

fprstateflagFlash 1.3.6.1.4.1.1166.6.1.2.9.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

fprstateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.11
The value of this object provides the label of the Alarm Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

fprstateflagAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.14
The value of this object provides the label of the Calibration Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

fprstateflagCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelFacCalSettingCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.17
The value of this object provides the label of the Factor Cal Setting CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueFacCalSettingCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

fprstateflagFacCalSettingCRC 1.3.6.1.4.1.1166.6.1.2.9.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprlabelInputSig 1.3.6.1.4.1.1166.6.1.2.9.4.3.20
The value of this object provides the label of the Input Sig Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprvalueInputSig 1.3.6.1.4.1.1166.6.1.2.9.4.3.21
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

fprstateflagInputSig 1.3.6.1.4.1.1166.6.1.2.9.4.3.22
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

fprgx2Rx1000FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.9.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

fprbootControlByte 1.3.6.1.4.1.1166.6.1.2.9.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fprbootStatusByte 1.3.6.1.4.1.1166.6.1.2.9.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fprbank0CRC 1.3.6.1.4.1.1166.6.1.2.9.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fprbank1CRC 1.3.6.1.4.1.1166.6.1.2.9.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fprprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.9.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fprfactoryCRC 1.3.6.1.4.1.1166.6.1.2.9.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fprcalculateCRC 1.3.6.1.4.1.1166.6.1.2.9.5.4.8
This object indicates which of the Emnums will have the CRC calculated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), calibration(2), alarmdata(3), calSetting(4)  

fprhourMeter 1.3.6.1.4.1.1166.6.1.2.9.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fprflashPrgCntA 1.3.6.1.4.1.1166.6.1.2.9.5.4.10
This object provides the number of times the flash has been programmed on side A.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fprflashPrgCntB 1.3.6.1.4.1.1166.6.1.2.9.5.4.11
This object provides the number of times the flash has been programmed on side B.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fprfwRev0 1.3.6.1.4.1.1166.6.1.2.9.5.4.12
This object provides the Revision of the firmware stores in bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

fprfwRev1 1.3.6.1.4.1.1166.6.1.2.9.5.4.13
This object provides the Revision of the firmware stores in bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gx2Rx1000HoldTimeTableIndex 1.3.6.1.4.1.1166.6.1.2.9.6.5.1
The value of this object is the index of the data object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2Rx1000HoldTimeSpecIndex 1.3.6.1.4.1.1166.6.1.2.9.6.5.2
The value of this object identifies the index of the alarm object to be modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2Rx1000HoldTimeData 1.3.6.1.4.1.1166.6.1.2.9.6.5.3
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

trapRX1000ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapRX1000ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapRX1000OpticalPowerAlarm 3
This trap is issued when the input Optical Power parameter goes out of range.
TRAP-TYPE    

trapRX1000ModuleTemperatureAlarm 4
This trap is issued when the RX1000 Module's Temperature goes out of range.
TRAP-TYPE    

trapRX1000HeatSinkTemperatureAlarm 5
This trap is issued when the RX1000 Heat Sink Temperature goes out of range.
TRAP-TYPE    

trapRX1000FanCurrentAlarm 6
This trap is issued when the RX1000 Module's Fan Currrent parameter goes out of range.
TRAP-TYPE    

trapRX1000Plus12CurrentAlarm 7
This trap is issued when the RX1000 Module's positive 12 volt current parameter goes out of range.
TRAP-TYPE    

trapRX1000OpticalSwitchAlarm 8
This trap is issued when the RX1000 Redundancy signal indicates a low input signal.
TRAP-TYPE    

trapRX1000Boot0Alarm 9
This trap is issued when the RX1000 Module's Bank 0 Boot sequence has detected an error.
TRAP-TYPE    

trapRX1000Boot1Alarm 10
This trap is issued when the RX1000 Module's Bank 1 Boot sequence has detected an error.
TRAP-TYPE    

trapRX1000FlashAlarm 11
This trap is issued when the RX1000 Module's boot or flash programming sequence has detected a Flash error.
TRAP-TYPE    

trapRX1000AlarmDataCRCAlarm 12
This trap is issued when the RX1000 Module detects an error calculating the alarm limit CRC.
TRAP-TYPE    

trapRX1000FactoryDataCRCAlarm 13
This trap is issued when the RX1000 Module detects an error calculating the Factory data CRC.
TRAP-TYPE    

trapRX1000CalDataCRCAlarm 14
This trap is issued when the RX1000 Module detects an error calculating the Calibration data CRC.
TRAP-TYPE    

trapRX1000ResetFacDefault 15
This trap is issued when the RX1000 resets to factory defaults
TRAP-TYPE    

trapRX1000FacCalSettingCRCAlarm 16
This trap is issued when the RX1000 Module detects factory calibration setting CRC alarm.
TRAP-TYPE