OMNI-gx2RSW200-MIB

File: OMNI-gx2RSW200-MIB.mib (54871 bytes)

Imported modules

RFC1155-SMI GX2HFC-MIB NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
DisplayString gx2Rsw200 trapIdentifier
trapNetworkElemModelNumber trapNetworkElemSerialNum trapPerceivedSeverity
trapNetworkElemOperState trapNetworkElemAlarmStatus trapNetworkElemAdminState
trapNetworkElemAvailStatus trapText trapNETrapLastTrapTimeStamp
trapChangedObjectId trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2Rsw200AnalogEntry  
SEQUENCE    
  gx2Rsw200AnalogTableIndex INTEGER
  rsw200labelModTemp DisplayString Size(0..80)
  rsw200uomModTemp DisplayString Size(0..80)
  rsw200majorHighModTemp Float
  rsw200majorLowModTemp Float
  rsw200minorHighModTemp Float
  rsw200minorLowModTemp Float
  rsw200currentValueModTemp Float
  rsw200stateFlagModTemp INTEGER
  rsw200minValueModTemp Float
  rsw200maxValueModTemp Float
  rsw200alarmStateModTemp INTEGER
  rsw200labelFanCurrent DisplayString Size(0..80)
  rsw200uomFanCurrent DisplayString Size(0..80)
  rsw200majorHighFanCurrent Float
  rsw200majorLowFanCurrent Float
  rsw200minorHighFanCurrent Float
  rsw200minorLowFanCurrent Float
  rsw200currentValueFanCurrent Float
  rsw200stateFlagFanCurrent INTEGER
  rsw200minValueFanCurrent Float
  rsw200maxValueFanCurrent Float
  rsw200alarmStateFanCurrent INTEGER

Gx2Rsw200DigitalEntry  
SEQUENCE    
  gx2Rsw200DigitalTableIndex INTEGER
  rsw200labelSwitchControl DisplayString Size(0..80)
  rsw200enumSwitchControl DisplayString Size(0..80)
  rsw200valueSwitchControl INTEGER
  rsw200stateflagSwitchControl INTEGER
  rsw200labelRevertMode DisplayString Size(0..80)
  rsw200enumRevertMode DisplayString Size(0..80)
  rsw200valueRevertMode INTEGER
  rsw200stateflagRevertMode INTEGER
  rsw200labelRevertTime DisplayString Size(0..80)
  rsw200enumRevertTime DisplayString Size(0..80)
  rsw200valueRevertTime INTEGER
  rsw200stateflagRevertTime INTEGER
  rsw200labelSwitchState DisplayString Size(0..80)
  rsw200enumSwitchState DisplayString Size(0..80)
  rsw200valueSwitchState INTEGER
  rsw200stateflagSwitchState INTEGER
  rsw200labelPriStatus DisplayString Size(0..80)
  rsw200enumPriStatus DisplayString Size(0..80)
  rsw200valuePriStatus INTEGER
  rsw200stateflagPriStatus INTEGER
  rsw200labelSecStatus DisplayString Size(0..80)
  rsw200enumSecStatus DisplayString Size(0..80)
  rsw200valueSecStatus INTEGER
  rsw200stateflagSecStatus INTEGER
  rsw200labelFactoryDefault DisplayString Size(0..80)
  rsw200enumFactoryDefault DisplayString Size(0..80)
  rsw200valueFactoryDefault INTEGER
  rsw200stateflagFactoryDefault INTEGER

Gx2Rsw200StatusEntry  
SEQUENCE    
  gx2Rsw200StatusTableIndex INTEGER
  rsw200labelBoot DisplayString Size(0..80)
  rsw200valueBoot INTEGER
  rsw200stateflagBoot INTEGER
  rsw200labelFlash DisplayString Size(0..80)
  rsw200valueFlash INTEGER
  rsw200stateflagFlash INTEGER
  rsw200labelFactoryDataCRC DisplayString Size(0..80)
  rsw200valueFactoryDataCRC INTEGER
  rsw200stateflagFactoryDataCRC INTEGER
  rsw200labelAlarmDataCrc DisplayString Size(0..80)
  rsw200valueAlarmDataCrc INTEGER
  rsw200stateflagAlarmDataCrc INTEGER
  rsw200labelRFSignalStatus DisplayString Size(0..80)
  rsw200valueRFSignalStatus INTEGER
  rsw200stateflagRFSignalStatus INTEGER
  rsw200labelPriActiveStatus DisplayString Size(0..80)
  rsw200valuePriActiveStatus INTEGER
  rsw200stateflagPriActiveStatus INTEGER

Gx2Rsw200FactoryEntry  
SEQUENCE    
  gx2Rsw200FactoryTableIndex INTEGER
  rsw200bootControlByte INTEGER
  rsw200bootStatusByte INTEGER
  rsw200bank1CRC INTEGER
  rsw200bank2CRC INTEGER
  rsw200prgEEPROMByte INTEGER
  rsw200factoryCRC INTEGER
  rsw200calculateCRC INTEGER
  rsw200hourMeter INTEGER
  rsw200flashPrgCntA INTEGER
  rsw200flashPrgCntB INTEGER
  rsw200flashBankARev DisplayString Size(0..80)
  rsw200flashBankBRev DisplayString Size(0..80)

Gx2Rsw200bHoldTimeEntry  
SEQUENCE    
  rxgx2Rsw200bHoldTimeTableIndex INTEGER
  rxgx2Rsw200bHoldTimeSpecIndex INTEGER
  rxgx2Rsw200bHoldTimeData INTEGER

Defined Values

gx2Rsw200Descriptor 1.3.6.1.4.1.1166.6.1.2.8.1
OBJECT IDENTIFIER    

gx2Rsw200AnalogTable 1.3.6.1.4.1.1166.6.1.2.8.2
This table contains gx2Rsw200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rsw200AnalogEntry

gx2Rsw200AnalogEntry 1.3.6.1.4.1.1166.6.1.2.8.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rsw200AnalogEntry  

gx2Rsw200DigitalTable 1.3.6.1.4.1.1166.6.1.2.8.3
This table contains gx2Rsw200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rsw200DigitalEntry

gx2Rsw200DigitalEntry 1.3.6.1.4.1.1166.6.1.2.8.3.2
This list contains digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rsw200DigitalEntry  

gx2Rsw200StatusTable 1.3.6.1.4.1.1166.6.1.2.8.4
This table contains gx2Rsw200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rsw200StatusEntry

gx2Rsw200StatusEntry 1.3.6.1.4.1.1166.6.1.2.8.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rsw200StatusEntry  

gx2Rsw200FactoryTable 1.3.6.1.4.1.1166.6.1.2.8.5
This table contains gx2Rsw200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rsw200FactoryEntry

gx2Rsw200FactoryEntry 1.3.6.1.4.1.1166.6.1.2.8.5.4
This list contains Factory parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rsw200FactoryEntry  

gx2Rsw200bHoldTimeTable 1.3.6.1.4.1.1166.6.1.2.8.6
This table contains gx2Rsw200b specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rsw200bHoldTimeEntry

gx2Rsw200bHoldTimeEntry 1.3.6.1.4.1.1166.6.1.2.8.6.5
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rsw200bHoldTimeEntry  

gx2Rsw200AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.8.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rsw200labelModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.2
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200uomModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.3
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200majorHighModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.4
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200majorLowModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.5
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200minorHighModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.6
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200minorLowModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.7
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200currentValueModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.8
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200stateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.9
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200minValueModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.10
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200maxValueModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.11
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200alarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.8.2.1.12
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rsw200labelFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.13
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200uomFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.14
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200majorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.15
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200majorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.16
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200minorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.17
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200minorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.18
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200currentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.19
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200stateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.20
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200minValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.21
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200maxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.22
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rsw200alarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.8.2.1.23
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2Rsw200DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.8.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rsw200labelSwitchControl 1.3.6.1.4.1.1166.6.1.2.8.3.2.2
The value of this object provides the label of the Switch Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200enumSwitchControl 1.3.6.1.4.1.1166.6.1.2.8.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueSwitchControl 1.3.6.1.4.1.1166.6.1.2.8.3.2.4
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

rsw200stateflagSwitchControl 1.3.6.1.4.1.1166.6.1.2.8.3.2.5
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelRevertMode 1.3.6.1.4.1.1166.6.1.2.8.3.2.6
The value of this object provides the label of the Revert Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200enumRevertMode 1.3.6.1.4.1.1166.6.1.2.8.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueRevertMode 1.3.6.1.4.1.1166.6.1.2.8.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER manual(1), autorevert(2), nonrevert(3)  

rsw200stateflagRevertMode 1.3.6.1.4.1.1166.6.1.2.8.3.2.9
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelRevertTime 1.3.6.1.4.1.1166.6.1.2.8.3.2.10
The value of this object provides the label of the Revert Time Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200enumRevertTime 1.3.6.1.4.1.1166.6.1.2.8.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueRevertTime 1.3.6.1.4.1.1166.6.1.2.8.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER tensec(1), sixtysec(2), sixhundredsec(3)  

rsw200stateflagRevertTime 1.3.6.1.4.1.1166.6.1.2.8.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelSwitchState 1.3.6.1.4.1.1166.6.1.2.8.3.2.14
The value of this object provides the label of the Switch State Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200enumSwitchState 1.3.6.1.4.1.1166.6.1.2.8.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueSwitchState 1.3.6.1.4.1.1166.6.1.2.8.3.2.16
The value of this object is the current value of the parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

rsw200stateflagSwitchState 1.3.6.1.4.1.1166.6.1.2.8.3.2.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelPriStatus 1.3.6.1.4.1.1166.6.1.2.8.3.2.18
The value of this object provides the label of the Primary Signal Status Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200enumPriStatus 1.3.6.1.4.1.1166.6.1.2.8.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valuePriStatus 1.3.6.1.4.1.1166.6.1.2.8.3.2.20
The value of this object is the current value of the parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER short(1), valid(2), invalid(3), open(4)  

rsw200stateflagPriStatus 1.3.6.1.4.1.1166.6.1.2.8.3.2.21
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelSecStatus 1.3.6.1.4.1.1166.6.1.2.8.3.2.22
The value of this object provides the label of the Secondary Signal Status Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200enumSecStatus 1.3.6.1.4.1.1166.6.1.2.8.3.2.23
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueSecStatus 1.3.6.1.4.1.1166.6.1.2.8.3.2.24
The value of this object is the current value of the parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER short(1), valid(2), invalid(3), open(4)  

rsw200stateflagSecStatus 1.3.6.1.4.1.1166.6.1.2.8.3.2.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.8.3.2.26
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200enumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.8.3.2.27
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.8.3.2.28
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

rsw200stateflagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.8.3.2.29
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Rsw200StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.8.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rsw200labelBoot 1.3.6.1.4.1.1166.6.1.2.8.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueBoot 1.3.6.1.4.1.1166.6.1.2.8.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rsw200stateflagBoot 1.3.6.1.4.1.1166.6.1.2.8.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelFlash 1.3.6.1.4.1.1166.6.1.2.8.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueFlash 1.3.6.1.4.1.1166.6.1.2.8.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rsw200stateflagFlash 1.3.6.1.4.1.1166.6.1.2.8.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.8.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.8.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rsw200stateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.8.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.8.4.3.11
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.8.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rsw200stateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.8.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelRFSignalStatus 1.3.6.1.4.1.1166.6.1.2.8.4.3.14
The value of this object provides the label of the RF Signal Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valueRFSignalStatus 1.3.6.1.4.1.1166.6.1.2.8.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rsw200stateflagRFSignalStatus 1.3.6.1.4.1.1166.6.1.2.8.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rsw200labelPriActiveStatus 1.3.6.1.4.1.1166.6.1.2.8.4.3.17
The value of this object provides the label of the Secondary Active Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200valuePriActiveStatus 1.3.6.1.4.1.1166.6.1.2.8.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rsw200stateflagPriActiveStatus 1.3.6.1.4.1.1166.6.1.2.8.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Rsw200FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.8.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rsw200bootControlByte 1.3.6.1.4.1.1166.6.1.2.8.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rsw200bootStatusByte 1.3.6.1.4.1.1166.6.1.2.8.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rsw200bank1CRC 1.3.6.1.4.1.1166.6.1.2.8.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rsw200bank2CRC 1.3.6.1.4.1.1166.6.1.2.8.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rsw200prgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.8.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rsw200factoryCRC 1.3.6.1.4.1.1166.6.1.2.8.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rsw200calculateCRC 1.3.6.1.4.1.1166.6.1.2.8.5.4.8
This object indicates which of the Emnums will have the CRC calculated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), alarm(2), na(3)  

rsw200hourMeter 1.3.6.1.4.1.1166.6.1.2.8.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rsw200flashPrgCntA 1.3.6.1.4.1.1166.6.1.2.8.5.4.10
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rsw200flashPrgCntB 1.3.6.1.4.1.1166.6.1.2.8.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rsw200flashBankARev 1.3.6.1.4.1.1166.6.1.2.8.5.4.12
This object provides the revision of flash bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rsw200flashBankBRev 1.3.6.1.4.1.1166.6.1.2.8.5.4.13
This object provides the revision of flash bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rxgx2Rsw200bHoldTimeTableIndex 1.3.6.1.4.1.1166.6.1.2.8.6.5.1
The value of this object is the index of the data object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rxgx2Rsw200bHoldTimeSpecIndex 1.3.6.1.4.1.1166.6.1.2.8.6.5.2
The value of this object identifies the index of the alarm object to be modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rxgx2Rsw200bHoldTimeData 1.3.6.1.4.1.1166.6.1.2.8.6.5.3
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

trapRSW200ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapRSW200ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapRSW200RFInputAlarm 3
This trap is issued when the Switch Control signals go out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRSW200FanCurrentAlarm 4
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRSW200ModuleTempAlarm 5
This trap is issued when the Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRSW200FlashAlarm 6
This trap is issued when the detects an error during Flash memory operations.
TRAP-TYPE    

trapRSW200BankBootAlarm 7
This trap is issued when the detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapRSW200AlarmDataCRCAlarm 8
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapRSW200FactoryDataCRCAlarm 9
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapRSW200InputSwitchedAlarm 10
This trap is issued when the RF input switched.
TRAP-TYPE    

trapRSW200ResetFactoryDefaultAlarm 11
This trap is issued when the Factory Default Reset occurs.
TRAP-TYPE    

trapRSW200SecondaryInputActiveAlarm 12
This trap is issued when the scondary input becomes active.
TRAP-TYPE