OMNI-gx2EDFA-MIB

File: OMNI-gx2EDFA-MIB.mib (129707 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2EDFA trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2EDFAAnalogEntry  
SEQUENCE    
  edfagx2EDFAAnalogTableIndex INTEGER
  edfalabelModTemp DisplayString Size(0..80)
  edfauomModTemp DisplayString Size(0..80)
  edfamajorHighModTemp Float
  edfamajorLowModTemp Float
  edfaminorHighModTemp Float
  edfaminorLowModTemp Float
  edfacurrentValueModTemp Float
  edfastateFlagModTemp INTEGER
  edfaminValueModTemp Float
  edfamaxValueModTemp Float
  edfaalarmStateModTemp INTEGER
  edfalabelOptInPower DisplayString Size(0..80)
  edfauomOptInPower DisplayString Size(0..80)
  edfamajorHighOptInPower Float
  edfamajorLowOptInPower Float
  edfaminorHighOptInPower Float
  edfaminorLowOptInPower Float
  edfacurrentValueOptInPower Float
  edfastateFlagOptInPower INTEGER
  edfaminValueOptInPower Float
  edfamaxValueOptInPower Float
  edfaalarmStateOptInPower INTEGER
  edfalabelOptOutPower DisplayString Size(0..80)
  edfauomOptOutPower DisplayString Size(0..80)
  edfamajorHighOptOutPower Float
  edfamajorLowOptOutPower Float
  edfaminorHighOptOutPower Float
  edfaminorLowOptOutPower Float
  edfacurrentValueOptOutPower Float
  edfastateFlagOptOutPower INTEGER
  edfaminValueOptOutPower Float
  edfamaxValueOptOutPower Float
  edfaalarmStateOptOutPower INTEGER
  edfalabelTECTemp DisplayString Size(0..80)
  edfauomTECTemp DisplayString Size(0..80)
  edfamajorHighTECTemp Float
  edfamajorLowTECTemp Float
  edfaminorHighTECTemp Float
  edfaminorLowTECTemp Float
  edfacurrentValueTECTemp Float
  edfastateFlagTECTemp INTEGER
  edfaminValueTECTemp Float
  edfamaxValueTECTemp Float
  edfaalarmStateTECTemp INTEGER
  edfalabelTECCurrent DisplayString Size(0..80)
  edfauomTECCurrent DisplayString Size(0..80)
  edfamajorHighTECCurrent Float
  edfamajorLowTECCurrent Float
  edfaminorHighTECCurrent Float
  edfaminorLowTECCurrent Float
  edfacurrentValueTECCurrent Float
  edfastateFlagTECCurrent INTEGER
  edfaminValueTECCurrent Float
  edfamaxValueTECCurrent Float
  edfaalarmStateTECCurrent INTEGER
  edfalabelLaserCurrent DisplayString Size(0..80)
  edfauomLaserCurrent DisplayString Size(0..80)
  edfamajorHighLaserCurrent Float
  edfamajorLowLaserCurrent Float
  edfaminorHighLaserCurrent Float
  edfaminorLowLaserCurrent Float
  edfacurrentValueLaserCurrent Float
  edfastateFlagLaserCurrent INTEGER
  edfaminValueLaserCurrent Float
  edfamaxValueLaserCurrent Float
  edfaalarmStateLaserCurrent INTEGER
  edfalabelLaserPower DisplayString Size(0..80)
  edfauomLaserPower DisplayString Size(0..80)
  edfamajorHighLaserPower Float
  edfamajorLowLaserPower Float
  edfaminorHighLaserPower Float
  edfaminorLowLaserPower Float
  edfacurrentValueLaserPower Float
  edfastateFlagLaserPower INTEGER
  edfaminValueLaserPower Float
  edfamaxValueLaserPower Float
  edfaalarmStateLaserPower INTEGER
  edfalabel12Volt DisplayString Size(0..80)
  edfauom12Volt DisplayString Size(0..80)
  edfamajorHigh12Volt Float
  edfamajorLow12Volt Float
  edfaminorHigh12Volt Float
  edfaminorLow12Volt Float
  edfacurrentValue12Volt Float
  edfastateFlag12Volt INTEGER
  edfaminValue12Volt Float
  edfamaxValue12Volt Float
  edfaalarmState12Volt INTEGER
  edfalabel37Volt DisplayString Size(0..80)
  edfauom37Volt DisplayString Size(0..80)
  edfamajorHigh37Volt Float
  edfamajorLow37Volt Float
  edfaminorHigh37Volt Float
  edfaminorLow37Volt Float
  edfacurrentValue37Volt Float
  edfastateFlag37Volt INTEGER
  edfaminValue37Volt Float
  edfamaxValue37Volt Float
  edfaalarmState37Volt INTEGER
  edfalabelFanCurrent DisplayString Size(0..80)
  edfauomFanCurrent DisplayString Size(0..80)
  edfamajorHighFanCurrent Float
  edfamajorLowFanCurrent Float
  edfaminorHighFanCurrent Float
  edfaminorLowFanCurrent Float
  edfacurrentValueFanCurrent Float
  edfastateFlagFanCurrent INTEGER
  edfaminValueFanCurrent Float
  edfamaxValueFanCurrent Float
  edfaalarmStateFanCurrent INTEGER
  edfalabelOPSetting DisplayString Size(0..80)
  edfauomOPSetting DisplayString Size(0..80)
  edfamajorHighOPSetting Float
  edfamajorLowOPSetting Float
  edfaminorHighOPSetting Float
  edfaminorLowOPSetting Float
  edfacurrentValueOPSetting Float
  edfastateFlagOPSetting INTEGER
  edfaminValueOPSetting Float
  edfamaxValueOPSetting Float
  edfaalarmStateOPSetting INTEGER
  edfalabelLPSetting DisplayString Size(0..80)
  edfauomLPSetting DisplayString Size(0..80)
  edfamajorHighLPSetting Float
  edfamajorLowLPSetting Float
  edfaminorHighLPSetting Float
  edfaminorLowLPSetting Float
  edfacurrentValueLPSetting Float
  edfastateFlagLPSetting INTEGER
  edfaminValueLPSetting Float
  edfamaxValueLPSetting Float
  edfaalarmStateLPSetting INTEGER
  edfalabelCGSetting DisplayString Size(0..80)
  edfauomCGSetting DisplayString Size(0..80)
  edfamajorHighCGSetting Float
  edfamajorLowCGSetting Float
  edfaminorHighCGSetting Float
  edfaminorLowCGSetting Float
  edfacurrentValueCGSetting Float
  edfastateFlagCGSetting INTEGER
  edfaminValueCGSetting Float
  edfamaxValueCGSetting Float
  edfaalarmStateCGSetting INTEGER
  edfalabelOptThreshold DisplayString Size(0..80)
  edfauomOptThreshold DisplayString Size(0..80)
  edfamajorHighOptThreshold Float
  edfamajorLowOptThreshold Float
  edfaminorHighOptThreshold Float
  edfaminorLowOptThreshold Float
  edfacurrentValueOptThreshold Float
  edfastateFlagOptThreshold INTEGER
  edfaminValueOptThreshold Float
  edfamaxValueOptThreshold Float
  edfaalarmStateOptThreshold INTEGER

Gx2EDFADigitalEntry  
SEQUENCE    
  edfagx2EDFADigitalTableIndex INTEGER
  edfalabelModeSetting DisplayString Size(0..80)
  edfavalueModeSetting INTEGER
  edfaenumModeSetting DisplayString Size(0..80)
  edfastateFlagModeSetting INTEGER
  edfalabelModuleState DisplayString Size(0..80)
  edfavalueModuleState INTEGER
  edfaenumModuleState DisplayString Size(0..80)
  edfastateFlagModuleState INTEGER
  edfalabelFactoryDefault DisplayString Size(0..80)
  edfavalueFactoryDefault INTEGER
  edfaenumFactoryDefault DisplayString Size(0..80)
  edfastateFlagFactoryDefault INTEGER

Gx2EDFAStatusEntry  
SEQUENCE    
  edfagx2EDFAStatusTableIndex INTEGER
  edfalabelBoot DisplayString Size(0..80)
  edfavalueBoot INTEGER
  edfastateflagBoot INTEGER
  edfalabelFlash DisplayString Size(0..80)
  edfavalueFlash INTEGER
  edfastateflagFlash INTEGER
  edfalabelFactoryDataCRC DisplayString Size(0..80)
  edfavalueFactoryDataCRC INTEGER
  edfastateflagFactoryDataCRC INTEGER
  edfalabelAlarmDataCRC DisplayString Size(0..80)
  edfavalueAlarmDataCRC INTEGER
  edfastateflagAlarmDataCRC INTEGER
  edfalabelCalibrationDataCRC DisplayString Size(0..80)
  edfavalueCalibrationDataCRC INTEGER
  edfastateflagCalibrationDataCRC INTEGER
  edfalabelOptInShutdown DisplayString Size(0..80)
  edfavalueOptInShutdown INTEGER
  edfastateflagOptInShutdown INTEGER
  edfalabelTECTempShutdown DisplayString Size(0..80)
  edfavalueTECTempShutdown INTEGER
  edfastateflagTECTempShutdown INTEGER
  edfalabelTECShutOverride DisplayString Size(0..80)
  edfavalueTECShutOverride INTEGER
  edfastateflagTECShutOverride INTEGER
  edfalabelPowerFail DisplayString Size(0..80)
  edfavaluePowerFail INTEGER
  edfastateflagPowerFail INTEGER
  edfalabelKeySwitch DisplayString Size(0..80)
  edfavalueKeySwitch INTEGER
  edfastateflagKeySwitch INTEGER
  edfalabelLaserCurrShutdown DisplayString Size(0..80)
  edfavalueLaserCurrShutdown INTEGER
  edfastateflagLaserCurrShutdown INTEGER
  edfalabelLaserPowShutdown DisplayString Size(0..80)
  edfavalueLaserPowShutdown INTEGER
  edfastateflagLaserPowShutdown INTEGER
  edfalabelADCStatus DisplayString Size(0..80)
  edfavalueADCStatus INTEGER
  edfastateflagADCStatus INTEGER
  edfalabelConstGainStatus DisplayString Size(0..80)
  edfavalueConstGainStatus INTEGER
  edfastateflagConstGainStatus INTEGER
  edfalabelStandbyStatus DisplayString Size(0..80)
  edfavalueStandbyStatus INTEGER
  edfastateflagStandbyStatus INTEGER

Gx2EDFAFactoryEntry  
SEQUENCE    
  edfagx2EDFAFactoryTableIndex INTEGER
  edfabootControlByte INTEGER
  edfabootStatusByte INTEGER
  edfabank0CRC INTEGER
  edfabank1CRC INTEGER
  edfaprgEEPROMByte INTEGER
  edfafactoryCRC INTEGER
  edfacalculateCRC INTEGER
  edfahourMeter INTEGER
  edfaflashPrgCntA INTEGER
  edfaflashPrgCntB INTEGER
  edfafwRev0 DisplayString Size(0..80)
  edfafwRev1 DisplayString Size(0..80)

Gx2EDFAHoldTimeEntry  
SEQUENCE    
  gx2EDFAHoldTimeTableIndex INTEGER
  gx2EDFAHoldTimeSpecIndex INTEGER
  gx2EDFAHoldTimeData INTEGER

Defined Values

gx2EDFADescriptor 1.3.6.1.4.1.1166.6.1.2.11.1
OBJECT IDENTIFIER    

gx2EDFAAnalogTable 1.3.6.1.4.1.1166.6.1.2.11.2
This table contains gx2EDFA specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2EDFAAnalogEntry

gx2EDFAAnalogEntry 1.3.6.1.4.1.1166.6.1.2.11.2.1
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2EDFAAnalogEntry  

gx2EDFADigitalTable 1.3.6.1.4.1.1166.6.1.2.11.3
This table contains gx2EDFA specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2EDFADigitalEntry

gx2EDFADigitalEntry 1.3.6.1.4.1.1166.6.1.2.11.3.2
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2EDFADigitalEntry  

gx2EDFAStatusTable 1.3.6.1.4.1.1166.6.1.2.11.4
This table contains gx2EDFA specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2EDFAStatusEntry

gx2EDFAStatusEntry 1.3.6.1.4.1.1166.6.1.2.11.4.3
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2EDFAStatusEntry  

gx2EDFAFactoryTable 1.3.6.1.4.1.1166.6.1.2.11.5
This table contains gx2EDFA specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2EDFAFactoryEntry

gx2EDFAFactoryEntry 1.3.6.1.4.1.1166.6.1.2.11.5.4
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2EDFAFactoryEntry  

gx2EDFAHoldTimeTable 1.3.6.1.4.1.1166.6.1.2.11.6
This table contains gx2EDFA specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2EDFAHoldTimeEntry

gx2EDFAHoldTimeEntry 1.3.6.1.4.1.1166.6.1.2.11.6.5
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2EDFAHoldTimeEntry  

edfagx2EDFAAnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.11.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

edfalabelModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.2
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.3
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.4
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.5
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.6
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.7
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.8
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfastateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.9
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.10
The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.11
The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.12
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.13
The value of this object provides the label of the Optical Input Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.14
The value of this object provides the Unit of Measure of the Optical Input Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.15
The value of this object provides the Major High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.16
The value of this object provides the Major Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.17
The value of this object provides the Minor High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.18
The value of this object provides the Minor Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.19
The value of this object provides the Current value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfastateFlagOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.20
The value of this object provides the state of the Optical Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.21
The value of this object provides the minimum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.22
The value of this object provides the maximum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateOptInPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.23
The value of this object provides the curent alarm state of the Optical Input Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.24
The value of this object provides the label of the Optical Output Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.25
The value of this object provides the Unit of Measure of the Optical Output Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.26
The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.27
The value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.28
The value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.29
The value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.30
The value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfastateFlagOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.31
The value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.32
The value of this object provides the minimum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.33
The value of this object provides the maximum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateOptOutPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.34
The value of this object provides the curent alarm state of the Optical Output Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.35
The value of this object provides the label of the TEC Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.36
The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.37
The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.38
The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.39
The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.40
The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.41
The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfastateFlagTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.42
The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.43
The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.44
The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateTECTemp 1.3.6.1.4.1.1166.6.1.2.11.2.1.45
The value of this object provides the curent alarm state of the TEC Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.46
The value of this object provides the label of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.47
The value of this object provides the Unit of Measure of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.48
The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.49
The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.50
The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.51
The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.52
The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfastateFlagTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.53
The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.54
The value of this object provides the minimum value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.55
The value of this object provides the maximum value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateTECCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.56
The value of this object provides the curent alarm state of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.57
The value of this object provides the label of the Laser Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.58
The value of this object provides the Unit of Measure of the Laser Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.59
The value of this object provides the Major High alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.60
The value of this object provides the Major Low alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.61
The value of this object provides the Minor High alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.62
The value of this object provides the Minor Low alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.63
The value of this object provides the Current value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfastateFlagLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.64
The value of this object provides the state of the Laser Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.65
The value of this object provides the minimum value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.66
The value of this object provides the maximum value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateLaserCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.67
The value of this object provides the curent alarm state of the Laser Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.68
The value of this object provides the label of the Laser Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.69
The value of this object provides the Unit of Measure of the Laser Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.70
The value of this object provides the Major High alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.71
The value of this object provides the Major Low alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.72
The value of this object provides the Minor High alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.73
The value of this object provides the Minor Low alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.74
The value of this object provides the Current value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfastateFlagLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.75
The value of this object provides the state of the Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.76
The value of this object provides the minimum value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.77
The value of this object provides the maximum value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateLaserPower 1.3.6.1.4.1.1166.6.1.2.11.2.1.78
The value of this object provides the curent alarm state of the Laser Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabel12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.79
The value of this object provides the label of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauom12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.80
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.81
The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLow12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.82
The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.83
The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLow12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.84
The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValue12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.85
The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfastateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.86
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValue12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.87
The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValue12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.88
The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmState12Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.89
The value of this object provides the curent alarm state of the 12v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabel37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.90
The value of this object provides the label of the 3.7v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauom37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.91
The value of this object provides the Unit of Measure of the 3.7v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHigh37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.92
The value of this object provides the Major High alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLow37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.93
The value of this object provides the Major Low alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHigh37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.94
The value of this object provides the Minor High alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLow37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.95
The value of this object provides the Minor Low alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValue37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.96
The value of this object provides the Current value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfastateFlag37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.97
The value of this object provides the state of the 3.7v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValue37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.98
The value of this object provides the minimum value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValue37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.99
The value of this object provides the maximum value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmState37Volt 1.3.6.1.4.1.1166.6.1.2.11.2.1.100
The value of this object provides the curent alarm state of the 3.7v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.101
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.102
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.103
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.104
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.105
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.106
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.107
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfastateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.108
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.109
The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.110
The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.11.2.1.111
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.112
The value of this object provides the label of the Output Power Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.113
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.114
The value of this object provides the Major High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.115
The value of this object provides the Major Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.116
The value of this object provides the Minor High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.117
The value of this object provides the Minor Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.118
The value of this object provides the Current value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

edfastateFlagOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.119
The value of this object provides the state of the Output Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.120
The value of this object provides the minimum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.121
The value of this object provides the maximum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateOPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.122
The value of this object provides the curent alarm state of the Output Power Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.123
The value of this object provides the label of the Laser Power Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.124
The value of this object provides the Unit of Measure of the Laser Power Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.125
The value of this object provides the Major High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.126
The value of this object provides the Major Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.127
The value of this object provides the Minor High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.128
The value of this object provides the Minor Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.129
The value of this object provides the Current value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

edfastateFlagLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.130
The value of this object provides the state of the Laser Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.131
The value of this object provides the minimum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.132
The value of this object provides the maximum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateLPSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.133
The value of this object provides the curent alarm state of the Laser Power Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.134
The value of this object provides the label of the Constant Gain Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.135
The value of this object provides the Unit of Measure of the Constant Gain Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.136
The value of this object provides the Major High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.137
The value of this object provides the Major Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.138
The value of this object provides the Minor High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.139
The value of this object provides the Minor Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.140
The value of this object provides the Current value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

edfastateFlagCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.141
The value of this object provides the state of the Constant Gain Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.142
The value of this object provides the minimum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.143
The value of this object provides the maximum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateCGSetting 1.3.6.1.4.1.1166.6.1.2.11.2.1.144
The value of this object provides the curent alarm state of the Constant Gain Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfalabelOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.145
The value of this object provides the label of the Optical Input Threshold Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfauomOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.146
The value of this object provides the Unit of Measure of the Optical Input Threshold Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfamajorHighOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.147
The value of this object provides the Major High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamajorLowOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.148
The value of this object provides the Major Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorHighOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.149
The value of this object provides the Minor High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaminorLowOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.150
The value of this object provides the Minor Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfacurrentValueOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.151
The value of this object provides the Current value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

edfastateFlagOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.152
The value of this object provides the state of the Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfaminValueOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.153
The value of this object provides the minimum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfamaxValueOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.154
The value of this object provides the maximum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

edfaalarmStateOptThreshold 1.3.6.1.4.1.1166.6.1.2.11.2.1.155
The value of this object provides the curent alarm state of the Optical Input Threshold Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

edfagx2EDFADigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.11.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

edfalabelModeSetting 1.3.6.1.4.1.1166.6.1.2.11.3.2.2
The value of this object provides the label of the EDFA's Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfaenumModeSetting 1.3.6.1.4.1.1166.6.1.2.11.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueModeSetting 1.3.6.1.4.1.1166.6.1.2.11.3.2.4
The value of this object is the current value of the parameter. It is an integer value from 0 to 5 representing the operation mode of the module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER power-out-preset(1), power-out-set(2), laser-power-preset(3), laser-power-set(4), constant-gain-preset(5), constant-gain-set(6)  

edfastateFlagModeSetting 1.3.6.1.4.1.1166.6.1.2.11.3.2.5
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelModuleState 1.3.6.1.4.1.1166.6.1.2.11.3.2.6
The value of this object provides the label of the Module State Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfaenumModuleState 1.3.6.1.4.1.1166.6.1.2.11.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueModuleState 1.3.6.1.4.1.1166.6.1.2.11.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

edfastateFlagModuleState 1.3.6.1.4.1.1166.6.1.2.11.3.2.9
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.11.3.2.10
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfaenumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.11.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.11.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

edfastateFlagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.11.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfagx2EDFAStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.11.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

edfalabelBoot 1.3.6.1.4.1.1166.6.1.2.11.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueBoot 1.3.6.1.4.1.1166.6.1.2.11.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagBoot 1.3.6.1.4.1.1166.6.1.2.11.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelFlash 1.3.6.1.4.1.1166.6.1.2.11.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueFlash 1.3.6.1.4.1.1166.6.1.2.11.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagFlash 1.3.6.1.4.1.1166.6.1.2.11.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.11.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.11.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.11.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.11.4.3.11
The value of this object provides the label of the Alarm Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.11.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.11.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.11.4.3.14
The value of this object provides the label of the Calibration Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.11.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.11.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelOptInShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.17
The value of this object provides the label of the Optical Input Power Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueOptInShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagOptInShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelTECTempShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.20
The value of this object provides the label of the TEC Temperature Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueTECTempShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.21
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagTECTempShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.22
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelTECShutOverride 1.3.6.1.4.1.1166.6.1.2.11.4.3.23
The value of this object provides the label of the TEC Shutdown Override Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueTECShutOverride 1.3.6.1.4.1.1166.6.1.2.11.4.3.24
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagTECShutOverride 1.3.6.1.4.1.1166.6.1.2.11.4.3.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelPowerFail 1.3.6.1.4.1.1166.6.1.2.11.4.3.26
The value of this object provides the label of the Power Supply Fail Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavaluePowerFail 1.3.6.1.4.1.1166.6.1.2.11.4.3.27
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagPowerFail 1.3.6.1.4.1.1166.6.1.2.11.4.3.28
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelKeySwitch 1.3.6.1.4.1.1166.6.1.2.11.4.3.29
The value of this object provides the label of the Key Switch Setting Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueKeySwitch 1.3.6.1.4.1.1166.6.1.2.11.4.3.30
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagKeySwitch 1.3.6.1.4.1.1166.6.1.2.11.4.3.31
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelLaserCurrShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.32
The value of this object provides the label of the Laser Current Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueLaserCurrShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.33
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagLaserCurrShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.34
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelLaserPowShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.35
The value of this object provides the label of the Laser Power Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueLaserPowShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.36
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagLaserPowShutdown 1.3.6.1.4.1.1166.6.1.2.11.4.3.37
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelADCStatus 1.3.6.1.4.1.1166.6.1.2.11.4.3.38
The value of this object provides the label of the ADC Operation Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueADCStatus 1.3.6.1.4.1.1166.6.1.2.11.4.3.39
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagADCStatus 1.3.6.1.4.1.1166.6.1.2.11.4.3.40
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelConstGainStatus 1.3.6.1.4.1.1166.6.1.2.11.4.3.41
The value of this object provides the label of the Constant Gain Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueConstGainStatus 1.3.6.1.4.1.1166.6.1.2.11.4.3.42
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagConstGainStatus 1.3.6.1.4.1.1166.6.1.2.11.4.3.43
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfalabelStandbyStatus 1.3.6.1.4.1.1166.6.1.2.11.4.3.44
The value of this object provides the label of the Standby Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfavalueStandbyStatus 1.3.6.1.4.1.1166.6.1.2.11.4.3.45
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

edfastateflagStandbyStatus 1.3.6.1.4.1.1166.6.1.2.11.4.3.46
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

edfagx2EDFAFactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.11.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

edfabootControlByte 1.3.6.1.4.1.1166.6.1.2.11.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

edfabootStatusByte 1.3.6.1.4.1.1166.6.1.2.11.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

edfabank0CRC 1.3.6.1.4.1.1166.6.1.2.11.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

edfabank1CRC 1.3.6.1.4.1.1166.6.1.2.11.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

edfaprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.11.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

edfafactoryCRC 1.3.6.1.4.1.1166.6.1.2.11.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

edfacalculateCRC 1.3.6.1.4.1.1166.6.1.2.11.5.4.8
This object indicates which of the Emnums will have the CRC calculated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), calibration(2), alarmdata(3)  

edfahourMeter 1.3.6.1.4.1.1166.6.1.2.11.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

edfaflashPrgCntA 1.3.6.1.4.1.1166.6.1.2.11.5.4.10
This object provides the number of times the flash has been programmed on side A.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

edfaflashPrgCntB 1.3.6.1.4.1.1166.6.1.2.11.5.4.11
This object provides the number of times the flash has been programmed on side B.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

edfafwRev0 1.3.6.1.4.1.1166.6.1.2.11.5.4.12
This object provides the Revision of the firmware stores in bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

edfafwRev1 1.3.6.1.4.1.1166.6.1.2.11.5.4.13
This object provides the Revision of the firmware stores in bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gx2EDFAHoldTimeTableIndex 1.3.6.1.4.1.1166.6.1.2.11.6.5.1
The value of this object is the index of the data object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2EDFAHoldTimeSpecIndex 1.3.6.1.4.1.1166.6.1.2.11.6.5.2
The value of this object identifies the index of the alarm object to be modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2EDFAHoldTimeData 1.3.6.1.4.1.1166.6.1.2.11.6.5.3
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

trapEDFAConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapEDFAConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapEDFAModuleTemperatureAlarm 3
This trap is issued when the EDFA Module's Temperature goes out of range.
TRAP-TYPE    

trapEDFAOpticalInPowerAlarm 4
This trap is issued when the input Optical Input Power parameter goes out of range.
TRAP-TYPE    

trapEDFAOpticalOutPowerAlarm 5
This trap is issued when the input Optical Output Power parameter goes out of range.
TRAP-TYPE    

trapEDFATECTemperatureAlarm 6
This trap is issued when the EDFA TEC Temperature goes out of range.
TRAP-TYPE    

trapEDFATECCurrentAlarm 7
This trap is issued when the EDFA TEC Current goes out of range.
TRAP-TYPE    

trapEDFALaserCurrentAlarm 8
This trap is issued when the EDFA Laser Current goes out of range.
TRAP-TYPE    

trapEDFALaserPowerAlarm 9
This trap is issued when the EDFA Laser Power goes out of range.
TRAP-TYPE    

trapEDFAPlus12CurrentAlarm 10
This trap is issued when the EDFA 12 volt current parameter goes out of range.
TRAP-TYPE    

trapEDFAPlus37CurrentAlarm 11
This trap is issued when the EDFA 3.7 volt current parameter goes out of range.
TRAP-TYPE    

trapEDFAFanCurrentAlarm 12
This trap is issued when the EDFA Module's Fan Currrent parameter goes out of range.
TRAP-TYPE    

trapEDFAResetFacDefault 13
This trap is issued when the EDFA resets to factory defaults
TRAP-TYPE    

trapEDFAStandbyMode 14
This trap is issued when the EDFA is in Standby Mode.
TRAP-TYPE    

trapEDFAOptInShutdown 15
This trap is issued when the EDFA is in Optical Input Shutdown.
TRAP-TYPE    

trapEDFATECTempShutdown 16
This trap is issued when the EDFA is in TEC Temperature Shutdown.
TRAP-TYPE    

trapEDFAKeySwitch 17
This trap is issued when the Key Switch disables the EDFA.
TRAP-TYPE    

trapEDFAPowerFail 18
This trap is issued when there is an EDFA Power Supply Failure.
TRAP-TYPE    

trapEDFALasCurrShutdown 19
This trap is issued when the EDFA is in Laser Current Shutdown.
TRAP-TYPE    

trapEDFALasPowerShutdown 20
This trap is issued when the EDFA is in Laser Power Shutdown.
TRAP-TYPE    

trapEDFAInvalidMode 21
This trap is issued when the EDFA is in an invalid mode.
TRAP-TYPE    

trapEDFAFlashAlarm 22
This trap is issued when the EDFA Module's boot or flash programming sequence has detected a Flash error.
TRAP-TYPE    

trapEDFABoot0Alarm 23
This trap is issued when the EDFA Module's Bank 0 Boot sequence has detected an error.
TRAP-TYPE    

trapEDFABoot1Alarm 24
This trap is issued when the EDFA Module's Bank 1 Boot sequence has detected an error.
TRAP-TYPE    

trapEDFAAlarmDataCRCAlarm 25
This trap is issued when the EDFA Module detects an error calculating the alarm limit CRC.
TRAP-TYPE    

trapEDFAFactoryDataCRCAlarm 26
This trap is issued when the EDFA Module detects an error calculating the Factory data CRC.
TRAP-TYPE    

trapEDFACalDataCRCAlarm 27
This trap is issued when the EDFA Module detects an error calculating the Calibration data CRC.
TRAP-TYPE    

trapEDFAFacCalFloatAlarm 28
This trap is issued when the EDFA Module detects factory calibration float data alarm.
TRAP-TYPE    

trapEDFAOptInThreshAlarm 29
This trap is issued when the EDFA Module Optical Input drops below the user set threshold.
TRAP-TYPE    

trapEDFAGainErrorAlarm 30
This trap is issued when the EDFA Module cannot produce the desired user set gain in Constant Gain Set Mode.
TRAP-TYPE