OMNI-gx2Dm870-MIB

File: OMNI-gx2Dm870-MIB.mib (90590 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Dm870 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2Dm870AnalogEntry  
SEQUENCE    
  gx2Dm870AnalogTableIndex INTEGER
  dm870labelOffsetNomMonitor DisplayString Size(0..80)
  dm870uomOffsetNomMonitor DisplayString Size(0..80)
  dm870majorHighOffsetNomMonitor Float
  dm870majorLowOffsetNomMonitor Float
  dm870minorHighOffsetNomMonitor Float
  dm870minorLowOffsetNomMonitor Float
  dm870currentValueOffsetNomMonitor Float
  dm870stateFlagOffsetNomMonitor INTEGER
  dm870minValueOffsetNomMonitor Float
  dm870maxValueOffsetNomMonitor Float
  dm870alarmStateOffsetNomMonitor INTEGER
  dm870labelOffsetNomCnt DisplayString Size(0..80)
  dm870uomOffsetNomCnt DisplayString Size(0..80)
  dm870majorHighOffsetNomCnt Float
  dm870majorLowOffsetNomCnt Float
  dm870minorHighOffsetNomCnt Float
  dm870minorLowOffsetNomCnt Float
  dm870currentValueOffsetNomCnt Float
  dm870stateFlagOffsetNomCnt INTEGER
  dm870minValueOffsetNomCnt Float
  dm870maxValueOffsetNomCnt Float
  dm870alarmStateOffsetNomCnt INTEGER
  dm870labelAttenSetting DisplayString Size(0..80)
  dm870uomAttenSetting DisplayString Size(0..80)
  dm870majorHighAttenSetting Float
  dm870majorLowAttenSetting Float
  dm870minorHighAttenSetting Float
  dm870minorLowAttenSetting Float
  dm870currentValueAttenSetting Float
  dm870stateFlagAttenSetting INTEGER
  dm870minValueAttenSetting Float
  dm870maxValueAttenSetting Float
  dm870alarmStateAttenSetting INTEGER
  dm870labelLaserPower DisplayString Size(0..80)
  dm870uomLaserPower DisplayString Size(0..80)
  dm870majorHighLaserPower Float
  dm870majorLowLaserPower Float
  dm870minorHighLaserPower Float
  dm870minorLowLaserPower Float
  dm870currentValueLaserPower Float
  dm870stateFlagLaserPower INTEGER
  dm870minValueLaserPower Float
  dm870maxValueLaserPower Float
  dm870alarmStateLaserPower INTEGER
  dm870labelLaserTemp DisplayString Size(0..80)
  dm870uomLaserTemp DisplayString Size(0..80)
  dm870majorHighLaserTemp Float
  dm870majorLowLaserTemp Float
  dm870minorHighLaserTemp Float
  dm870minorLowLaserTemp Float
  dm870currentValueLaserTemp Float
  dm870stateFlagLaserTemp INTEGER
  dm870minValueLaserTemp Float
  dm870maxValueLaserTemp Float
  dm870alarmStateLaserTemp INTEGER
  dm870labelLaserCurrent DisplayString Size(0..80)
  dm870uomLaserCurrent DisplayString Size(0..80)
  dm870majorHighLaserCurrent Float
  dm870majorLowLaserCurrent Float
  dm870minorHighLaserCurrent Float
  dm870minorLowLaserCurrent Float
  dm870currentValueLaserCurrent Float
  dm870stateFlagLaserCurrent INTEGER
  dm870minValueLaserCurrent Float
  dm870maxValueLaserCurrent Float
  dm870alarmStateLaserCurrent INTEGER
  dm870labelTecCurrent DisplayString Size(0..80)
  dm870uomTecCurrent DisplayString Size(0..80)
  dm870majorHighTecCurrent Float
  dm870majorLowTecCurrent Float
  dm870minorHighTecCurrent Float
  dm870minorLowTecCurrent Float
  dm870currentValueTecCurrent Float
  dm870stateFlagTecCurrent INTEGER
  dm870minValueTecCurrent Float
  dm870maxValueTecCurrent Float
  dm870alarmStateTecCurrent INTEGER
  dm870labelModTemp DisplayString Size(0..80)
  dm870uomModTemp DisplayString Size(0..80)
  dm870majorHighModTemp Float
  dm870majorLowModTemp Float
  dm870minorHighModTemp Float
  dm870minorLowModTemp Float
  dm870currentValueModTemp Float
  dm870stateFlagModTemp INTEGER
  dm870minValueModTemp Float
  dm870maxValueModTemp Float
  dm870alarmStateModTemp INTEGER
  dm870labelFanCurrent DisplayString Size(0..80)
  dm870uomFanCurrent DisplayString Size(0..80)
  dm870majorHighFanCurrent Float
  dm870majorLowFanCurrent Float
  dm870minorHighFanCurrent Float
  dm870minorLowFanCurrent Float
  dm870currentValueFanCurrent Float
  dm870stateFlagFanCurrent INTEGER
  dm870minValueFanCurrent Float
  dm870maxValueFanCurrent Float
  dm870alarmStateFanCurrent INTEGER

Gx2Dm870DigitalEntry  
SEQUENCE    
  gx2Dm870DigitalTableIndex INTEGER
  dm870labelRfInput DisplayString Size(0..80)
  dm870enumRfInput DisplayString Size(0..80)
  dm870valueRfInput INTEGER
  dm870stateflagRfInput INTEGER
  dm870labelOptOutput DisplayString Size(0..80)
  dm870enumOptOutput DisplayString Size(0..80)
  dm870valueOptOutput INTEGER
  dm870stateflagOptOutput INTEGER
  dm870labelSbsControl DisplayString Size(0..80)
  dm870enumSbsControl DisplayString Size(0..80)
  dm870valueSbsControl INTEGER
  dm870stateflagSbsControl INTEGER
  dm870labelLaserMode DisplayString Size(0..80)
  dm870enumLaserMode DisplayString Size(0..80)
  dm870valueLaserMode INTEGER
  dm870stateflagLaserMode INTEGER
  dm870labelFactoryDefault DisplayString Size(0..80)
  dm870enumFactoryDefault DisplayString Size(0..80)
  dm870valueFactoryDefault INTEGER
  dm870stateflagFactoryDefault INTEGER

Gx2Dm870StatusEntry  
SEQUENCE    
  gx2Dm870StatusTableIndex INTEGER
  dm870labelBoot DisplayString Size(0..80)
  dm870valueBoot INTEGER
  dm870stateflagBoot INTEGER
  dm870labelFlash DisplayString Size(0..80)
  dm870valueFlash INTEGER
  dm870stateflagFlash INTEGER
  dm870labelFactoryDataCRC DisplayString Size(0..80)
  dm870valueFactoryDataCRC INTEGER
  dm870stateflagFactoryDataCRC INTEGER
  dm870labelLaserDataCRC DisplayString Size(0..80)
  dm870valueLaserDataCRC INTEGER
  dm870stateflagLaserDataCRC INTEGER
  dm870labelAlarmDataCrc DisplayString Size(0..80)
  dm870valueAlarmDataCrc INTEGER
  dm870stateflagAlarmDataCrc INTEGER
  dm870labelRFInputStatus DisplayString Size(0..80)
  dm870valueRFInputStatus INTEGER
  dm870stateflagRFInputStatus INTEGER

Gx2Dm870FactoryEntry  
SEQUENCE    
  gx2Dm870FactoryTableIndex INTEGER
  dm870bootControlByte INTEGER
  dm870bootStatusByte INTEGER
  dm870bank1CRC INTEGER
  dm870bank2CRC INTEGER
  dm870prgEEPROMByte INTEGER
  dm870factoryCRC INTEGER
  dm870calculateCRC INTEGER
  dm870hourMeter INTEGER
  dm870flashPrgCntA INTEGER
  dm870flashPrgCntB INTEGER
  dm870flashBankARev DisplayString Size(0..80)
  dm870flashBankBRev DisplayString Size(0..80)

Defined Values

gx2Dm870Descriptor 1.3.6.1.4.1.1166.6.1.2.16.1
OBJECT IDENTIFIER    

gx2Dm870AnalogTable 1.3.6.1.4.1.1166.6.1.2.16.2
This table contains gx2Dm870 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm870AnalogEntry

gx2Dm870AnalogEntry 1.3.6.1.4.1.1166.6.1.2.16.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm870AnalogEntry  

gx2Dm870DigitalTable 1.3.6.1.4.1.1166.6.1.2.16.3
This table contains gx2Dm870m specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm870DigitalEntry

gx2Dm870DigitalEntry 1.3.6.1.4.1.1166.6.1.2.16.3.2
This list contains digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm870DigitalEntry  

gx2Dm870StatusTable 1.3.6.1.4.1.1166.6.1.2.16.4
This table contains gx2Dm870 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm870StatusEntry

gx2Dm870StatusEntry 1.3.6.1.4.1.1166.6.1.2.16.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm870StatusEntry  

gx2Dm870FactoryTable 1.3.6.1.4.1.1166.6.1.2.16.5
This table contains gx2Dm870 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm870FactoryEntry

gx2Dm870FactoryEntry 1.3.6.1.4.1.1166.6.1.2.16.5.4
This list contains Factory parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm870FactoryEntry  

gx2Dm870AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.16.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm870labelOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.2
The value of this object provides the label of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870uomOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.3
The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870majorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.4
The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870majorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.5
The value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870minorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.6
The value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870minorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.7
The value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870currentValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.8
The value of this object provides the Current value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870stateFlagOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.9
The value of this object provides the state of the Offset Monitor Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870minValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.10
The value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870maxValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.11
The value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870alarmStateOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.16.2.1.12
The value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm870labelOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.13
The value of this object provides the label of the Offset Control Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870uomOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.14
The value of this object provides the Unit of Measure of the Offset Control Analog parameter..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870majorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.15
The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870majorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.16
The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870minorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.17
The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870minorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.18
The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870currentValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.19
The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

dm870stateFlagOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.20
The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870minValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.21
The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870maxValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.22
The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870alarmStateOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.16.2.1.23
The value of this object provides the curent alarm state of the Offset Control Analog parameter.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm870labelAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.24
The value of this object provides the label of the Attenuator Setting Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870uomAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.25
The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870majorHighAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.26
The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870majorLowAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.27
The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870minorHighAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.28
The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870minorLowAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.29
The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870currentValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.30
The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

dm870stateFlagAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.31
The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870minValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.32
The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870maxValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.33
The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870alarmStateAttenSetting 1.3.6.1.4.1.1166.6.1.2.16.2.1.34
The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm870labelLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.35
The value of this object provides the label of the Laser Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870uomLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.36
The value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870majorHighLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.37
The value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870majorLowLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.38
The value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870minorHighLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.39
The value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870minorLowLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.40
The value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870currentValueLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.41
The value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870stateFlagLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.42
The value of this object provides the state of the Laser Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870minValueLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.43
The value of this object provides the minimum value the Laser Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870maxValueLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.44
The value of this object provides the maximum value the Laser Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870alarmStateLaserPower 1.3.6.1.4.1.1166.6.1.2.16.2.1.45
The value of this object provides the curent alarm state of the Laser Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm870labelLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.46
The value of this object provides the label of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870uomLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.47
The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870majorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.48
The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870majorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.49
The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870minorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.50
The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870minorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.51
The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870currentValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.52
The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870stateFlagLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.53
The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870minValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.54
The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870maxValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.55
The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870alarmStateLaserTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.56
The value of this object provides the curent alarm state of the Laser Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm870labelLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.57
The value of this object provides the label of the Laser Bias Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870uomLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.58
The value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870majorHighLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.59
The value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870majorLowLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.60
The value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870minorHighLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.61
The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870minorLowLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.62
The value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870currentValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.63
The value of this object provides the Current value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870stateFlagLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.64
The value of this object provides the state of the Laser Bias Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870minValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.65
The value of this object provides the minimum value the Laser Bias Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870maxValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.66
The value of this object provides the maximum value the Laser Bias Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870alarmStateLaserCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.67
The value of this object provides the curent alarm state of the Laser Bias Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm870labelTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.68
The value of this object provides the label of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870uomTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.69
The value of this object provides the Unit of Measure of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870majorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.70
The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870majorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.71
The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870minorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.72
The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870minorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.73
The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870currentValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.74
The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870stateFlagTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.75
The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870minValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.76
The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870maxValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.77
The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870alarmStateTecCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.78
The value of this object provides the curent alarm state of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm870labelModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.79
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870uomModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.80
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870majorHighModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.81
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870majorLowModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.82
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870minorHighModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.83
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870minorLowModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.84
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870currentValueModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.85
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870stateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.86
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870minValueModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.87
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870maxValueModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.88
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870alarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.16.2.1.89
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm870labelFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.90
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870uomFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.91
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870majorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.92
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870majorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.93
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870minorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.94
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870minorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.95
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm870currentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.96
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870stateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.97
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870minValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.98
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870maxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.99
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm870alarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.16.2.1.100
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2Dm870DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.16.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm870labelRfInput 1.3.6.1.4.1.1166.6.1.2.16.3.2.2
The value of this object provides the label of the RF Input Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870enumRfInput 1.3.6.1.4.1.1166.6.1.2.16.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueRfInput 1.3.6.1.4.1.1166.6.1.2.16.3.2.4
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm870stateflagRfInput 1.3.6.1.4.1.1166.6.1.2.16.3.2.5
The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870labelOptOutput 1.3.6.1.4.1.1166.6.1.2.16.3.2.6
The value of this object provides the label of the Optical Output Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870enumOptOutput 1.3.6.1.4.1.1166.6.1.2.16.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueOptOutput 1.3.6.1.4.1.1166.6.1.2.16.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm870stateflagOptOutput 1.3.6.1.4.1.1166.6.1.2.16.3.2.9
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870labelSbsControl 1.3.6.1.4.1.1166.6.1.2.16.3.2.10
The value of this object provides the label of the SBS Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870enumSbsControl 1.3.6.1.4.1.1166.6.1.2.16.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueSbsControl 1.3.6.1.4.1.1166.6.1.2.16.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm870stateflagSbsControl 1.3.6.1.4.1.1166.6.1.2.16.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870labelLaserMode 1.3.6.1.4.1.1166.6.1.2.16.3.2.14
The value of this object provides the label of the Laser Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870enumLaserMode 1.3.6.1.4.1.1166.6.1.2.16.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueLaserMode 1.3.6.1.4.1.1166.6.1.2.16.3.2.16
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER preset(1), set(2), setEquate(3), manual(4), manualEquate(5)  

dm870stateflagLaserMode 1.3.6.1.4.1.1166.6.1.2.16.3.2.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870labelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.16.3.2.18
The value of this object provides the label of the Factory Default Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870enumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.16.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.16.3.2.20
The value of this object is the current value of the parameter. Return value is meaningless
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm870stateflagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.16.3.2.21
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Dm870StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.16.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm870labelBoot 1.3.6.1.4.1.1166.6.1.2.16.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueBoot 1.3.6.1.4.1.1166.6.1.2.16.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm870stateflagBoot 1.3.6.1.4.1.1166.6.1.2.16.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870labelFlash 1.3.6.1.4.1.1166.6.1.2.16.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueFlash 1.3.6.1.4.1.1166.6.1.2.16.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm870stateflagFlash 1.3.6.1.4.1.1166.6.1.2.16.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870labelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.16.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.16.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm870stateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.16.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870labelLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.16.4.3.11
The value of this object provides the label of the Laser Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.16.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm870stateflagLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.16.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870labelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.16.4.3.14
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.16.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm870stateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.16.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm870labelRFInputStatus 1.3.6.1.4.1.1166.6.1.2.16.4.3.17
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870valueRFInputStatus 1.3.6.1.4.1.1166.6.1.2.16.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm870stateflagRFInputStatus 1.3.6.1.4.1.1166.6.1.2.16.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Dm870FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.16.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm870bootControlByte 1.3.6.1.4.1.1166.6.1.2.16.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm870bootStatusByte 1.3.6.1.4.1.1166.6.1.2.16.5.4.3
This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm870bank1CRC 1.3.6.1.4.1.1166.6.1.2.16.5.4.4
This object provides the CRC code of bank 0. The display formate for the data is Hex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm870bank2CRC 1.3.6.1.4.1.1166.6.1.2.16.5.4.5
This object provides the CRC code of bank 1.The display formate for the data is Hex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm870prgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.16.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm870factoryCRC 1.3.6.1.4.1.1166.6.1.2.16.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm870calculateCRC 1.3.6.1.4.1.1166.6.1.2.16.5.4.8
This object indicates which of the Enums will have the CRC calculated.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), na(2), alarm(3)  

dm870hourMeter 1.3.6.1.4.1.1166.6.1.2.16.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm870flashPrgCntA 1.3.6.1.4.1.1166.6.1.2.16.5.4.10
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm870flashPrgCntB 1.3.6.1.4.1.1166.6.1.2.16.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm870flashBankARev 1.3.6.1.4.1.1166.6.1.2.16.5.4.12
This object provides the revision of flash bank 0. The rev is 2 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm870flashBankBRev 1.3.6.1.4.1.1166.6.1.2.16.5.4.13
This object provides the revision of flash bank 1. The rev is 2 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

trapDM870ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapDM870ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapDM870fanCurrentAlarm 3
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM870ModuleTempAlarm 4
This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM870omiOffsetAlarm 5
This trap is issued when the OMI Offset goes out of range.
TRAP-TYPE    

trapDM870tecCurrentAlarm 6
This trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM870LaserCurrentAlarm 7
This trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM870LaserTempAlarm 8
This trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM870LaserPowerAlarm 9
This trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM870FlashAlarm 10
This trap is issued when the Laser Modules detects an error during Flash memory operations.
TRAP-TYPE    

trapDM870BankBootAlarm 11
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapDM870AlarmDataCRCAlarm 12
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapDM870FactoryDataCRCAlarm 13
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapDM870CalDataCRCAlarm 14
This trap is issued when the Cal Data CRC is incorrect.
TRAP-TYPE    

trapDM870ResetFacDefault 15
This trap is issued when the DM870 resets to factory defaults
TRAP-TYPE    

trapDM870UserRFOffAlarm 16
This trap is issued when the the User RF is turned off.
TRAP-TYPE    

trapDM870UserOpticalOffAlarm 17
This trap is issued when the User Optical Power is turned off.
TRAP-TYPE    

trapDM870UserSBSOffAlarm 18
This trap is issued when the User SBS is turned off.
TRAP-TYPE    

trapDM870RFInputAlarm 19
This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM870RFOverloadAlarm 20
This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE