OMNI-gx2Dm200-MIB

File: OMNI-gx2Dm200-MIB.mib (79404 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 GX2HFC-MIB NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE DisplayString TRAP-TYPE
gx2Dm200 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2Dm200AnalogEntry  
SEQUENCE    
  gx2Dm200AnalogTableIndex INTEGER
  dm200labelOffsetNomMonitor DisplayString Size(0..80)
  dm200uomOffsetNomMonitor DisplayString Size(0..80)
  dm200majorHighOffsetNomMonitor Float
  dm200majorLowOffsetNomMonitor Float
  dm200minorHighOffsetNomMonitor Float
  dm200minorLowOffsetNomMonitor Float
  dm200currentValueOffsetNomMonitor Float
  dm200stateFlagOffsetNomMonitor INTEGER
  dm200minValueOffsetNomMonitor Float
  dm200maxValueOffsetNomMonitor Float
  dm200alarmStateOffsetNomMonitor INTEGER
  dm200labelAttenSetting DisplayString Size(0..80)
  dm200uomAttenSetting DisplayString Size(0..80)
  dm200majorHighAttenSetting Float
  dm200majorLowAttenSetting Float
  dm200minorHighAttenSetting Float
  dm200minorLowAttenSetting Float
  dm200currentValueAttenSetting Float
  dm200stateFlagAttenSetting INTEGER
  dm200minValueAttenSetting Float
  dm200maxValueAttenSetting Float
  dm200alarmStateAttenSetting INTEGER
  dm200labelLaserPower DisplayString Size(0..80)
  dm200uomLaserPower DisplayString Size(0..80)
  dm200majorHighLaserPower Float
  dm200majorLowLaserPower Float
  dm200minorHighLaserPower Float
  dm200minorLowLaserPower Float
  dm200currentValueLaserPower Float
  dm200stateFlagLaserPower INTEGER
  dm200minValueLaserPower Float
  dm200maxValueLaserPower Float
  dm200alarmStateLaserPower INTEGER
  dm200labelLaserTemp DisplayString Size(0..80)
  dm200uomLaserTemp DisplayString Size(0..80)
  dm200majorHighLaserTemp Float
  dm200majorLowLaserTemp Float
  dm200minorHighLaserTemp Float
  dm200minorLowLaserTemp Float
  dm200currentValueLaserTemp Float
  dm200stateFlagLaserTemp INTEGER
  dm200minValueLaserTemp Float
  dm200maxValueLaserTemp Float
  dm200alarmStateLaserTemp INTEGER
  dm200labelLaserCurrent DisplayString Size(0..80)
  dm200uomLaserCurrent DisplayString Size(0..80)
  dm200majorHighLaserCurrent Float
  dm200majorLowLaserCurrent Float
  dm200minorHighLaserCurrent Float
  dm200minorLowLaserCurrent Float
  dm200currentValueLaserCurrent Float
  dm200stateFlagLaserCurrent INTEGER
  dm200minValueLaserCurrent Float
  dm200maxValueLaserCurrent Float
  dm200alarmStateLaserCurrent INTEGER
  dm200labelTecCurrent DisplayString Size(0..80)
  dm200uomTecCurrent DisplayString Size(0..80)
  dm200majorHighTecCurrent Float
  dm200majorLowTecCurrent Float
  dm200minorHighTecCurrent Float
  dm200minorLowTecCurrent Float
  dm200currentValueTecCurrent Float
  dm200stateFlagTecCurrent INTEGER
  dm200minValueTecCurrent Float
  dm200maxValueTecCurrent Float
  dm200alarmStateTecCurrent INTEGER
  dm200labelModTemp DisplayString Size(0..80)
  dm200uomModTemp DisplayString Size(0..80)
  dm200majorHighModTemp Float
  dm200majorLowModTemp Float
  dm200minorHighModTemp Float
  dm200minorLowModTemp Float
  dm200currentValueModTemp Float
  dm200stateFlagModTemp INTEGER
  dm200minValueModTemp Float
  dm200maxValueModTemp Float
  dm200alarmStateModTemp INTEGER
  dm200labelFanCurrent DisplayString Size(0..80)
  dm200uomFanCurrent DisplayString Size(0..80)
  dm200majorHighFanCurrent Float
  dm200majorLowFanCurrent Float
  dm200minorHighFanCurrent Float
  dm200minorLowFanCurrent Float
  dm200currentValueFanCurrent Float
  dm200stateFlagFanCurrent INTEGER
  dm200minValueFanCurrent Float
  dm200maxValueFanCurrent Float
  dm200alarmStateFanCurrent INTEGER

Gx2Dm200DigitalEntry  
SEQUENCE    
  gx2Dm200DigitalTableIndex INTEGER
  dm200labelRfInput DisplayString Size(0..80)
  dm200enumRfInput DisplayString Size(0..80)
  dm200valueRfInput INTEGER
  dm200stateflagRfInput INTEGER
  dm200labelOptOutput DisplayString Size(0..80)
  dm200enumOptOutput DisplayString Size(0..80)
  dm200valueOptOutput INTEGER
  dm200stateflagOptOutput INTEGER
  dm200labelSbsControl DisplayString Size(0..80)
  dm200enumSbsControl DisplayString Size(0..80)
  dm200valueSbsControl INTEGER
  dm200stateflagSbsControl INTEGER
  dm200labelFactoryDefault DisplayString Size(0..80)
  dm200enumFactoryDefault DisplayString Size(0..80)
  dm200valueFactoryDefault INTEGER
  dm200stateflagFactoryDefault INTEGER

Gx2Dm200StatusEntry  
SEQUENCE    
  gx2Dm200StatusTableIndex INTEGER
  dm200labelBoot DisplayString Size(0..80)
  dm200valueBoot INTEGER
  dm200stateflagBoot INTEGER
  dm200labelFlash DisplayString Size(0..80)
  dm200valueFlash INTEGER
  dm200stateflagFlash INTEGER
  dm200labelFactoryDataCRC DisplayString Size(0..80)
  dm200valueFactoryDataCRC INTEGER
  dm200stateflagFactoryDataCRC INTEGER
  dm200labelLaserDataCRC DisplayString Size(0..80)
  dm200valueLaserDataCRC INTEGER
  dm200stateflagLaserDataCRC INTEGER
  dm200labelAlarmDataCrc DisplayString Size(0..80)
  dm200valueAlarmDataCrc INTEGER
  dm200stateflagAlarmDataCrc INTEGER
  dm200labelRFInputStatus DisplayString Size(0..80)
  dm200valueRFInputStatus INTEGER
  dm200stateflagRFInputStatus INTEGER

Gx2Dm200FactoryEntry  
SEQUENCE    
  gx2Dm200FactoryTableIndex INTEGER
  dm200bootControlByte INTEGER
  dm200bootStatusByte INTEGER
  dm200bank1CRC INTEGER
  dm200bank2CRC INTEGER
  dm200prgEEPROMByte INTEGER
  dm200factoryCRC INTEGER
  dm200calculateCRC INTEGER
  dm200hourMeter INTEGER
  dm200flashPrgCntA INTEGER
  dm200flashPrgCntB INTEGER
  dm200flashBankARev DisplayString Size(0..80)
  dm200flashBankBRev DisplayString Size(0..80)

Defined Values

gx2Dm200Descriptor 1.3.6.1.4.1.1166.6.1.2.19.1
OBJECT IDENTIFIER    

gx2Dm200AnalogTable 1.3.6.1.4.1.1166.6.1.2.19.2
This table contains gx2Dm200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm200AnalogEntry

gx2Dm200AnalogEntry 1.3.6.1.4.1.1166.6.1.2.19.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm200AnalogEntry  

gx2Dm200DigitalTable 1.3.6.1.4.1.1166.6.1.2.19.3
This table contains gx2Dm200m specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm200DigitalEntry

gx2Dm200DigitalEntry 1.3.6.1.4.1.1166.6.1.2.19.3.2
This list contains digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm200DigitalEntry  

gx2Dm200StatusTable 1.3.6.1.4.1.1166.6.1.2.19.4
This table contains gx2Dm200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm200StatusEntry

gx2Dm200StatusEntry 1.3.6.1.4.1.1166.6.1.2.19.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm200StatusEntry  

gx2Dm200FactoryTable 1.3.6.1.4.1.1166.6.1.2.19.5
This table contains gx2Dm200 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm200FactoryEntry

gx2Dm200FactoryEntry 1.3.6.1.4.1.1166.6.1.2.19.5.4
This list contains Factory parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm200FactoryEntry  

gx2Dm200AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.19.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

dm200labelOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.2
The value of this object provides the label of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200uomOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.3
The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. The unit of measure for this parameter is dB
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200majorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.4
The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200majorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.5
The value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200minorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.6
The value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200minorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.7
The value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200currentValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.8
The value of this object provides the Current value of the Offset Monitor Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200stateFlagOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.9
The value of this object provides the state of the Offset Monitor Power Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200minValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.10
The value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200maxValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.11
The value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200alarmStateOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.12
The value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm200labelAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.13
The value of this object provides the label of the Attenuator Setting Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200uomAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.14
The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter. The unit of measure for this parameter is dB
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200majorHighAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.15
The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200majorLowAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.16
The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200minorHighAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.17
The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200minorLowAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.18
The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200currentValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.19
The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

dm200stateFlagAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.20
The value of this object provides the state of the Attenuator Setting Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200minValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.21
The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200maxValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.22
The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200alarmStateAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.23
The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm200labelLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.24
The value of this object provides the label of the Laser Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200uomLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.25
The value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter. The unit of measure for this parameter is dBm
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200majorHighLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.26
The value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200majorLowLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.27
The value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200minorHighLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.28
The value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200minorLowLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.29
The value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200currentValueLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.30
The value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200stateFlagLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.31
The value of this object provides the state of the Laser Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200minValueLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.32
The value of this object provides the minimum value the Laser Optical Power Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200maxValueLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.33
The value of this object provides the maximum value the Laser Optical Power Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200alarmStateLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.34
The value of this object provides the curent alarm state of the Laser Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm200labelLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.35
The value of this object provides the label of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200uomLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.36
The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. The unit of measure for this parameter is degrees C
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200majorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.37
The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200majorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.38
The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200minorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.39
The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200minorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.40
The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200currentValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.41
The value of this object provides the Current value of the Laser Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200stateFlagLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.42
The value of this object provides the state of the Laser Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200minValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.43
The value of this object provides the minimum value the Laser Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200maxValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.44
The value of this object provides the maximum value the Laser Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200alarmStateLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.45
The value of this object provides the curent alarm state of the Laser Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm200labelLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.46
The value of this object provides the label of the Laser Bias Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200uomLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.47
The value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter. The unit of measure for this parameter is mA
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200majorHighLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.48
The value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200majorLowLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.49
The value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200minorHighLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.50
The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200minorLowLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.51
The value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200currentValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.52
The value of this object provides the Current value of the Laser Bias Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200stateFlagLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.53
The value of this object provides the state of the Laser Bias Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200minValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.54
The value of this object provides the minimum value the Laser Bias Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200maxValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.55
The value of this object provides the maximum value the Laser Bias Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200alarmStateLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.56
The value of this object provides the curent alarm state of the Laser Bias Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm200labelTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.57
The value of this object provides the label of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200uomTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.58
The value of this object provides the Unit of Measure of the TEC Current Analog parameter. The unit of measure for this parameter is mA
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200majorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.59
The value of this object provides the Major High alarm value of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200majorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.60
The value of this object provides the Major Low alarm value of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200minorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.61
The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200minorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.62
The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200currentValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.63
The value of this object provides the Current value of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200stateFlagTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.64
The value of this object provides the state of the TEC Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200minValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.65
The value of this object provides the minimum value the TEC Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200maxValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.66
The value of this object provides the maximum value the TEC Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200alarmStateTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.67
The value of this object provides the curent alarm state of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm200labelModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.68
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200uomModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.69
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is degrees C
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200majorHighModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.70
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200majorLowModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.71
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200minorHighModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.72
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200minorLowModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.73
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200currentValueModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.74
The value of this object provides the Current value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200stateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.75
The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200minValueModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.76
The value of this object provides the minimum value the Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200maxValueModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.77
The value of this object provides the maximum value the Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200alarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.78
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm200labelFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.79
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200uomFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.80
The value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mA
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200majorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.81
The value of this object provides the Major High alarm value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200majorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.82
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200minorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.83
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200minorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.84
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm200currentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.85
The value of this object provides the Current value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200stateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.86
The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200minValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.87
The value of this object provides the minimum value the Fan Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200maxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.88
The value of this object provides the maximum value the Fan Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm200alarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.89
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2Dm200DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.19.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

dm200labelRfInput 1.3.6.1.4.1.1166.6.1.2.19.3.2.2
The value of this object provides the label of the RF Input Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200enumRfInput 1.3.6.1.4.1.1166.6.1.2.19.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200valueRfInput 1.3.6.1.4.1.1166.6.1.2.19.3.2.4
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm200stateflagRfInput 1.3.6.1.4.1.1166.6.1.2.19.3.2.5
The value of this object provides the state of the RF Input Control Digital parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200labelOptOutput 1.3.6.1.4.1.1166.6.1.2.19.3.2.6
The value of this object provides the label of the Optical Output Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200enumOptOutput 1.3.6.1.4.1.1166.6.1.2.19.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200valueOptOutput 1.3.6.1.4.1.1166.6.1.2.19.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm200stateflagOptOutput 1.3.6.1.4.1.1166.6.1.2.19.3.2.9
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200labelSbsControl 1.3.6.1.4.1.1166.6.1.2.19.3.2.10
The value of this object provides the label of the SBS Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200enumSbsControl 1.3.6.1.4.1.1166.6.1.2.19.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200valueSbsControl 1.3.6.1.4.1.1166.6.1.2.19.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm200stateflagSbsControl 1.3.6.1.4.1.1166.6.1.2.19.3.2.13
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200labelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.19.3.2.14
The value of this object provides the label of the Factory Default Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200enumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.19.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200valueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.19.3.2.16
The value of this object is the current value of the parameter. Return value is meaningless
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm200stateflagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.19.3.2.17
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Dm200StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.19.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

dm200labelBoot 1.3.6.1.4.1.1166.6.1.2.19.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200valueBoot 1.3.6.1.4.1.1166.6.1.2.19.4.3.3
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm200stateflagBoot 1.3.6.1.4.1.1166.6.1.2.19.4.3.4
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200labelFlash 1.3.6.1.4.1.1166.6.1.2.19.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200valueFlash 1.3.6.1.4.1.1166.6.1.2.19.4.3.6
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm200stateflagFlash 1.3.6.1.4.1.1166.6.1.2.19.4.3.7
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200labelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200valueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.9
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm200stateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.10
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200labelLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.11
The value of this object provides the label of the Laser Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200valueLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.12
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm200stateflagLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.13
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200labelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.19.4.3.14
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200valueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.19.4.3.15
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm200stateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.19.4.3.16
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm200labelRFInputStatus 1.3.6.1.4.1.1166.6.1.2.19.4.3.17
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200valueRFInputStatus 1.3.6.1.4.1.1166.6.1.2.19.4.3.18
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm200stateflagRFInputStatus 1.3.6.1.4.1.1166.6.1.2.19.4.3.19
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Dm200FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.19.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

dm200bootControlByte 1.3.6.1.4.1.1166.6.1.2.19.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm200bootStatusByte 1.3.6.1.4.1.1166.6.1.2.19.5.4.3
This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm200bank1CRC 1.3.6.1.4.1.1166.6.1.2.19.5.4.4
This object provides the CRC code of bank 0. The display formate for the data is Hex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm200bank2CRC 1.3.6.1.4.1.1166.6.1.2.19.5.4.5
This object provides the CRC code of bank 1.The display formate for the data is Hex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm200prgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.19.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm200factoryCRC 1.3.6.1.4.1.1166.6.1.2.19.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm200calculateCRC 1.3.6.1.4.1.1166.6.1.2.19.5.4.8
This object indicates which of the Enums will have the CRC calculated.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), na(2), alarm(3)  

dm200hourMeter 1.3.6.1.4.1.1166.6.1.2.19.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm200flashPrgCntA 1.3.6.1.4.1.1166.6.1.2.19.5.4.10
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm200flashPrgCntB 1.3.6.1.4.1.1166.6.1.2.19.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm200flashBankARev 1.3.6.1.4.1.1166.6.1.2.19.5.4.12
This object provides the revision of flash bank 0. The rev is 2 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm200flashBankBRev 1.3.6.1.4.1.1166.6.1.2.19.5.4.13
This object provides the revision of flash bank 1. The rev is 2 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

trapDM200ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapDM200ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapDM200fanCurrentAlarm 3
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM200ModuleTempAlarm 4
This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM200omiOffsetAlarm 5
This trap is issued when the OMI Offset goes out of range.
TRAP-TYPE    

trapDM200tecCurrentAlarm 6
This trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM200LaserCurrentAlarm 7
This trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM200LaserTempAlarm 8
This trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM200LaserPowerAlarm 9
This trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM200FlashAlarm 10
This trap is issued when the Laser Modules detects an error during Flash memory operations.
TRAP-TYPE    

trapDM200BankBootAlarm 11
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapDM200AlarmDataCRCAlarm 12
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapDM200FactoryDataCRCAlarm 13
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapDM200CalDataCRCAlarm 14
This trap is issued when the Cal Data CRC is incorrect.
TRAP-TYPE    

trapDM200ResetFacDefault 15
This trap is issued when the DM200 resets to factory defaults
TRAP-TYPE    

trapDM200UserRFOffAlarm 16
This trap is issued when the the User RF is turned off.
TRAP-TYPE    

trapDM200UserOpticalOffAlarm 17
This trap is issued when the User Optical Power is turned off.
TRAP-TYPE    

trapDM200UserSBSOffAlarm 18
This trap is issued when the User SBS is turned off.
TRAP-TYPE    

trapDM200RFInputAlarm 19
This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM200RFOverloadAlarm 20
This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE