OMNI-gx2Dm1000-MIB

File: OMNI-gx2Dm1000-MIB.mib (91112 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Dm1000 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2Dm1000AnalogEntry  
SEQUENCE    
  gx2Dm1000AnalogTableIndex INTEGER
  dm1000labelOffsetNomMonitor DisplayString Size(0..80)
  dm1000uomOffsetNomMonitor DisplayString Size(0..80)
  dm1000majorHighOffsetNomMonitor Float
  dm1000majorLowOffsetNomMonitor Float
  dm1000minorHighOffsetNomMonitor Float
  dm1000minorLowOffsetNomMonitor Float
  dm1000currentValueOffsetNomMonitor Float
  dm1000stateFlagOffsetNomMonitor INTEGER
  dm1000minValueOffsetNomMonitor Float
  dm1000maxValueOffsetNomMonitor Float
  dm1000alarmStateOffsetNomMonitor INTEGER
  dm1000labelOffsetNomCnt DisplayString Size(0..80)
  dm1000uomOffsetNomCnt DisplayString Size(0..80)
  dm1000majorHighOffsetNomCnt Float
  dm1000majorLowOffsetNomCnt Float
  dm1000minorHighOffsetNomCnt Float
  dm1000minorLowOffsetNomCnt Float
  dm1000currentValueOffsetNomCnt Float
  dm1000stateFlagOffsetNomCnt INTEGER
  dm1000minValueOffsetNomCnt Float
  dm1000maxValueOffsetNomCnt Float
  dm1000alarmStateOffsetNomCnt INTEGER
  dm1000labelAttenSetting DisplayString Size(0..80)
  dm1000uomAttenSetting DisplayString Size(0..80)
  dm1000majorHighAttenSetting Float
  dm1000majorLowAttenSetting Float
  dm1000minorHighAttenSetting Float
  dm1000minorLowAttenSetting Float
  dm1000currentValueAttenSetting Float
  dm1000stateFlagAttenSetting INTEGER
  dm1000minValueAttenSetting Float
  dm1000maxValueAttenSetting Float
  dm1000alarmStateAttenSetting INTEGER
  dm1000labelLaserPower DisplayString Size(0..80)
  dm1000uomLaserPower DisplayString Size(0..80)
  dm1000majorHighLaserPower Float
  dm1000majorLowLaserPower Float
  dm1000minorHighLaserPower Float
  dm1000minorLowLaserPower Float
  dm1000currentValueLaserPower Float
  dm1000stateFlagLaserPower INTEGER
  dm1000minValueLaserPower Float
  dm1000maxValueLaserPower Float
  dm1000alarmStateLaserPower INTEGER
  dm1000labelLaserTemp DisplayString Size(0..80)
  dm1000uomLaserTemp DisplayString Size(0..80)
  dm1000majorHighLaserTemp Float
  dm1000majorLowLaserTemp Float
  dm1000minorHighLaserTemp Float
  dm1000minorLowLaserTemp Float
  dm1000currentValueLaserTemp Float
  dm1000stateFlagLaserTemp INTEGER
  dm1000minValueLaserTemp Float
  dm1000maxValueLaserTemp Float
  dm1000alarmStateLaserTemp INTEGER
  dm1000labelLaserCurrent DisplayString Size(0..80)
  dm1000uomLaserCurrent DisplayString Size(0..80)
  dm1000majorHighLaserCurrent Float
  dm1000majorLowLaserCurrent Float
  dm1000minorHighLaserCurrent Float
  dm1000minorLowLaserCurrent Float
  dm1000currentValueLaserCurrent Float
  dm1000stateFlagLaserCurrent INTEGER
  dm1000minValueLaserCurrent Float
  dm1000maxValueLaserCurrent Float
  dm1000alarmStateLaserCurrent INTEGER
  dm1000labelTecCurrent DisplayString Size(0..80)
  dm1000uomTecCurrent DisplayString Size(0..80)
  dm1000majorHighTecCurrent Float
  dm1000majorLowTecCurrent Float
  dm1000minorHighTecCurrent Float
  dm1000minorLowTecCurrent Float
  dm1000currentValueTecCurrent Float
  dm1000stateFlagTecCurrent INTEGER
  dm1000minValueTecCurrent Float
  dm1000maxValueTecCurrent Float
  dm1000alarmStateTecCurrent INTEGER
  dm1000labelModTemp DisplayString Size(0..80)
  dm1000uomModTemp DisplayString Size(0..80)
  dm1000majorHighModTemp Float
  dm1000majorLowModTemp Float
  dm1000minorHighModTemp Float
  dm1000minorLowModTemp Float
  dm1000currentValueModTemp Float
  dm1000stateFlagModTemp INTEGER
  dm1000minValueModTemp Float
  dm1000maxValueModTemp Float
  dm1000alarmStateModTemp INTEGER
  dm1000labelFanCurrent DisplayString Size(0..80)
  dm1000uomFanCurrent DisplayString Size(0..80)
  dm1000majorHighFanCurrent Float
  dm1000majorLowFanCurrent Float
  dm1000minorHighFanCurrent Float
  dm1000minorLowFanCurrent Float
  dm1000currentValueFanCurrent Float
  dm1000stateFlagFanCurrent INTEGER
  dm1000minValueFanCurrent Float
  dm1000maxValueFanCurrent Float
  dm1000alarmStateFanCurrent INTEGER

Gx2Dm1000DigitalEntry  
SEQUENCE    
  gx2Dm1000DigitalTableIndex INTEGER
  dm1000labelRfInput DisplayString Size(0..80)
  dm1000enumRfInput DisplayString Size(0..80)
  dm1000valueRfInput INTEGER
  dm1000stateflagRfInput INTEGER
  dm1000labelOptOutput DisplayString Size(0..80)
  dm1000enumOptOutput DisplayString Size(0..80)
  dm1000valueOptOutput INTEGER
  dm1000stateflagOptOutput INTEGER
  dm1000labelSbsControl DisplayString Size(0..80)
  dm1000enumSbsControl DisplayString Size(0..80)
  dm1000valueSbsControl INTEGER
  dm1000stateflagSbsControl INTEGER
  dm1000labelLaserMode DisplayString Size(0..80)
  dm1000enumLaserMode DisplayString Size(0..80)
  dm1000valueLaserMode INTEGER
  dm1000stateflagLaserMode INTEGER
  dm1000labelFactoryDefault DisplayString Size(0..80)
  dm1000enumFactoryDefault DisplayString Size(0..80)
  dm1000valueFactoryDefault INTEGER
  dm1000stateflagFactoryDefault INTEGER

Gx2Dm1000StatusEntry  
SEQUENCE    
  gx2Dm1000StatusTableIndex INTEGER
  dm1000labelBoot DisplayString Size(0..80)
  dm1000valueBoot INTEGER
  dm1000stateflagBoot INTEGER
  dm1000labelFlash DisplayString Size(0..80)
  dm1000valueFlash INTEGER
  dm1000stateflagFlash INTEGER
  dm1000labelFactoryDataCRC DisplayString Size(0..80)
  dm1000valueFactoryDataCRC INTEGER
  dm1000stateflagFactoryDataCRC INTEGER
  dm1000labelLaserDataCRC DisplayString Size(0..80)
  dm1000valueLaserDataCRC INTEGER
  dm1000stateflagLaserDataCRC INTEGER
  dm1000labelAlarmDataCrc DisplayString Size(0..80)
  dm1000valueAlarmDataCrc INTEGER
  dm1000stateflagAlarmDataCrc INTEGER
  dm1000labelRFInputStatus DisplayString Size(0..80)
  dm1000valueRFInputStatus INTEGER
  dm1000stateflagRFInputStatus INTEGER

Gx2Dm1000FactoryEntry  
SEQUENCE    
  gx2Dm1000FactoryTableIndex INTEGER
  dm1000bootControlByte INTEGER
  dm1000bootStatusByte INTEGER
  dm1000bank1CRC INTEGER
  dm1000bank2CRC INTEGER
  dm1000prgEEPROMByte INTEGER
  dm1000factoryCRC INTEGER
  dm1000calculateCRC INTEGER
  dm1000hourMeter INTEGER
  dm1000flashPrgCntA INTEGER
  dm1000flashPrgCntB INTEGER
  dm1000flashBankARev DisplayString Size(0..80)
  dm1000flashBankBRev DisplayString Size(0..80)

Defined Values

gx2Dm1000Descriptor 1.3.6.1.4.1.1166.6.1.2.28.1
OBJECT IDENTIFIER    

gx2Dm1000AnalogTable 1.3.6.1.4.1.1166.6.1.2.28.2
This table contains gx2Dm1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm1000AnalogEntry

gx2Dm1000AnalogEntry 1.3.6.1.4.1.1166.6.1.2.28.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm1000AnalogEntry  

gx2Dm1000DigitalTable 1.3.6.1.4.1.1166.6.1.2.28.3
This table contains gx2Dm1000m specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm1000DigitalEntry

gx2Dm1000DigitalEntry 1.3.6.1.4.1.1166.6.1.2.28.3.2
This list contains digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm1000DigitalEntry  

gx2Dm1000StatusTable 1.3.6.1.4.1.1166.6.1.2.28.4
This table contains gx2Dm1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm1000StatusEntry

gx2Dm1000StatusEntry 1.3.6.1.4.1.1166.6.1.2.28.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm1000StatusEntry  

gx2Dm1000FactoryTable 1.3.6.1.4.1.1166.6.1.2.28.5
This table contains gx2Dm1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm1000FactoryEntry

gx2Dm1000FactoryEntry 1.3.6.1.4.1.1166.6.1.2.28.5.4
This list contains Factory parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm1000FactoryEntry  

gx2Dm1000AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.28.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm1000labelOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.2
The value of this object provides the label of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000uomOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.3
The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000majorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.4
The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000majorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.5
The value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.6
The value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.7
The value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000currentValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.8
The value of this object provides the Current value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000stateFlagOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.9
The value of this object provides the state of the Offset Monitor Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000minValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.10
The value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000maxValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.11
The value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000alarmStateOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.28.2.1.12
The value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm1000labelOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.13
The value of this object provides the label of the Offset Control Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000uomOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.14
The value of this object provides the Unit of Measure of the Offset Control Analog parameter..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000majorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.15
The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000majorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.16
The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.17
The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.18
The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000currentValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.19
The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

dm1000stateFlagOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.20
The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000minValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.21
The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000maxValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.22
The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000alarmStateOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.28.2.1.23
The value of this object provides the curent alarm state of the Offset Control Analog parameter.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm1000labelAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.24
The value of this object provides the label of the Attenuator Setting Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000uomAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.25
The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000majorHighAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.26
The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000majorLowAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.27
The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorHighAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.28
The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorLowAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.29
The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000currentValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.30
The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

dm1000stateFlagAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.31
The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000minValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.32
The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000maxValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.33
The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000alarmStateAttenSetting 1.3.6.1.4.1.1166.6.1.2.28.2.1.34
The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm1000labelLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.35
The value of this object provides the label of the Laser Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000uomLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.36
The value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000majorHighLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.37
The value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000majorLowLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.38
The value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorHighLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.39
The value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorLowLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.40
The value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000currentValueLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.41
The value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000stateFlagLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.42
The value of this object provides the state of the Laser Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000minValueLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.43
The value of this object provides the minimum value the Laser Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000maxValueLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.44
The value of this object provides the maximum value the Laser Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000alarmStateLaserPower 1.3.6.1.4.1.1166.6.1.2.28.2.1.45
The value of this object provides the curent alarm state of the Laser Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm1000labelLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.46
The value of this object provides the label of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000uomLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.47
The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000majorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.48
The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000majorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.49
The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.50
The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.51
The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000currentValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.52
The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000stateFlagLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.53
The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000minValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.54
The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000maxValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.55
The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000alarmStateLaserTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.56
The value of this object provides the curent alarm state of the Laser Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm1000labelLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.57
The value of this object provides the label of the Laser Bias Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000uomLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.58
The value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000majorHighLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.59
The value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000majorLowLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.60
The value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorHighLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.61
The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorLowLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.62
The value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000currentValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.63
The value of this object provides the Current value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000stateFlagLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.64
The value of this object provides the state of the Laser Bias Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000minValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.65
The value of this object provides the minimum value the Laser Bias Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000maxValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.66
The value of this object provides the maximum value the Laser Bias Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000alarmStateLaserCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.67
The value of this object provides the curent alarm state of the Laser Bias Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm1000labelTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.68
The value of this object provides the label of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000uomTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.69
The value of this object provides the Unit of Measure of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000majorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.70
The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000majorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.71
The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.72
The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.73
The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000currentValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.74
The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000stateFlagTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.75
The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000minValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.76
The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000maxValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.77
The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000alarmStateTecCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.78
The value of this object provides the curent alarm state of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm1000labelModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.79
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000uomModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.80
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000majorHighModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.81
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000majorLowModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.82
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorHighModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.83
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorLowModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.84
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000currentValueModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.85
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000stateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.86
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000minValueModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.87
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000maxValueModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.88
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000alarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.28.2.1.89
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm1000labelFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.90
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000uomFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.91
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000majorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.92
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000majorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.93
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.94
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000minorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.95
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dm1000currentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.96
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000stateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.97
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000minValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.98
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000maxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.99
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm1000alarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.28.2.1.100
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2Dm1000DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.28.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm1000labelRfInput 1.3.6.1.4.1.1166.6.1.2.28.3.2.2
The value of this object provides the label of the RF Input Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000enumRfInput 1.3.6.1.4.1.1166.6.1.2.28.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueRfInput 1.3.6.1.4.1.1166.6.1.2.28.3.2.4
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm1000stateflagRfInput 1.3.6.1.4.1.1166.6.1.2.28.3.2.5
The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000labelOptOutput 1.3.6.1.4.1.1166.6.1.2.28.3.2.6
The value of this object provides the label of the Optical Output Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000enumOptOutput 1.3.6.1.4.1.1166.6.1.2.28.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueOptOutput 1.3.6.1.4.1.1166.6.1.2.28.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm1000stateflagOptOutput 1.3.6.1.4.1.1166.6.1.2.28.3.2.9
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000labelSbsControl 1.3.6.1.4.1.1166.6.1.2.28.3.2.10
The value of this object provides the label of the SBS Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000enumSbsControl 1.3.6.1.4.1.1166.6.1.2.28.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueSbsControl 1.3.6.1.4.1.1166.6.1.2.28.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm1000stateflagSbsControl 1.3.6.1.4.1.1166.6.1.2.28.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000labelLaserMode 1.3.6.1.4.1.1166.6.1.2.28.3.2.14
The value of this object provides the label of the Laser Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000enumLaserMode 1.3.6.1.4.1.1166.6.1.2.28.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueLaserMode 1.3.6.1.4.1.1166.6.1.2.28.3.2.16
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER preset(1), set(2), setEquate(3), manual(4), manualEquate(5)  

dm1000stateflagLaserMode 1.3.6.1.4.1.1166.6.1.2.28.3.2.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000labelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.28.3.2.18
The value of this object provides the label of the Factory Default Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000enumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.28.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.28.3.2.20
The value of this object is the current value of the parameter. Return value is meaningless
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm1000stateflagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.28.3.2.21
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Dm1000StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.28.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm1000labelBoot 1.3.6.1.4.1.1166.6.1.2.28.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueBoot 1.3.6.1.4.1.1166.6.1.2.28.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm1000stateflagBoot 1.3.6.1.4.1.1166.6.1.2.28.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000labelFlash 1.3.6.1.4.1.1166.6.1.2.28.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueFlash 1.3.6.1.4.1.1166.6.1.2.28.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm1000stateflagFlash 1.3.6.1.4.1.1166.6.1.2.28.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000labelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.28.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.28.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm1000stateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.28.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000labelLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.28.4.3.11
The value of this object provides the label of the Laser Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.28.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm1000stateflagLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.28.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000labelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.28.4.3.14
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.28.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm1000stateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.28.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm1000labelRFInputStatus 1.3.6.1.4.1.1166.6.1.2.28.4.3.17
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000valueRFInputStatus 1.3.6.1.4.1.1166.6.1.2.28.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm1000stateflagRFInputStatus 1.3.6.1.4.1.1166.6.1.2.28.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Dm1000FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.28.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm1000bootControlByte 1.3.6.1.4.1.1166.6.1.2.28.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm1000bootStatusByte 1.3.6.1.4.1.1166.6.1.2.28.5.4.3
This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm1000bank1CRC 1.3.6.1.4.1.1166.6.1.2.28.5.4.4
This object provides the CRC code of bank 0. The display formate for the data is Hex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm1000bank2CRC 1.3.6.1.4.1.1166.6.1.2.28.5.4.5
This object provides the CRC code of bank 1.The display formate for the data is Hex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm1000prgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.28.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm1000factoryCRC 1.3.6.1.4.1.1166.6.1.2.28.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm1000calculateCRC 1.3.6.1.4.1.1166.6.1.2.28.5.4.8
This object indicates which of the Enums will have the CRC calculated.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), na(2), alarm(3)  

dm1000hourMeter 1.3.6.1.4.1.1166.6.1.2.28.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm1000flashPrgCntA 1.3.6.1.4.1.1166.6.1.2.28.5.4.10
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm1000flashPrgCntB 1.3.6.1.4.1.1166.6.1.2.28.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm1000flashBankARev 1.3.6.1.4.1.1166.6.1.2.28.5.4.12
This object provides the revision of flash bank 0. The rev is 2 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm1000flashBankBRev 1.3.6.1.4.1.1166.6.1.2.28.5.4.13
This object provides the revision of flash bank 1. The rev is 2 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

trapDM1000ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapDM1000ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapDM1000fanCurrentAlarm 3
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM1000ModuleTempAlarm 4
This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM1000omiOffsetAlarm 5
This trap is issued when the OMI Offset goes out of range.
TRAP-TYPE    

trapDM1000tecCurrentAlarm 6
This trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM1000LaserCurrentAlarm 7
This trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM1000LaserTempAlarm 8
This trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM1000LaserPowerAlarm 9
This trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM1000FlashAlarm 10
This trap is issued when the Laser Modules detects an error during Flash memory operations.
TRAP-TYPE    

trapDM1000BankBootAlarm 11
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapDM1000AlarmDataCRCAlarm 12
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapDM1000FactoryDataCRCAlarm 13
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapDM1000CalDataCRCAlarm 14
This trap is issued when the Cal Data CRC is incorrect.
TRAP-TYPE    

trapDM1000ResetFacDefault 15
This trap is issued when the DM1000 resets to factory defaults
TRAP-TYPE    

trapDM1000UserRFOffAlarm 16
This trap is issued when the the User RF is turned off.
TRAP-TYPE    

trapDM1000UserOpticalOffAlarm 17
This trap is issued when the User Optical Power is turned off.
TRAP-TYPE    

trapDM1000UserSBSOffAlarm 18
This trap is issued when the User SBS is turned off.
TRAP-TYPE    

trapDM1000RFInputAlarm 19
This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM1000RFOverloadAlarm 20
This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE