OMNI-gx2DM2000-MIB

File: OMNI-gx2DM2000-MIB.mib (106326 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Dm2000 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2dm2000AnalogEntry  
SEQUENCE    
  gx2dm2000AnalogTableIndex INTEGER
  dm2000labelOffsetNomMonitor DisplayString Size(0..80)
  dm2000uomOffsetNomMonitor DisplayString Size(0..80)
  dm2000majorHighOffsetNomMonitor Float
  dm2000majorLowOffsetNomMonitor Float
  dm2000minorHighOffsetNomMonitor Float
  dm2000minorLowOffsetNomMonitor Float
  dm2000currentValueOffsetNomMonitor Float
  dm2000stateFlagOffsetNomMonitor INTEGER
  dm2000minValueOffsetNomMonitor Float
  dm2000maxValueOffsetNomMonitor Float
  dm2000alarmStateOffsetNomMonitor INTEGER
  dm2000labelOffsetNomCnt DisplayString Size(0..80)
  dm2000uomOffsetNomCnt DisplayString Size(0..80)
  dm2000majorHighOffsetNomCnt Float
  dm2000majorLowOffsetNomCnt Float
  dm2000minorHighOffsetNomCnt Float
  dm2000minorLowOffsetNomCnt Float
  dm2000currentValueOffsetNomCnt Float
  dm2000stateFlagOffsetNomCnt INTEGER
  dm2000minValueOffsetNomCnt Float
  dm2000maxValueOffsetNomCnt Float
  dm2000alarmStateOffsetNomCnt INTEGER
  dm2000labelRelAttenSetting DisplayString Size(0..80)
  dm2000uomRelAttenSetting DisplayString Size(0..80)
  dm2000majorHighRelAttenSetting Float
  dm2000majorLowRelAttenSetting Float
  dm2000minorHighRelAttenSetting Float
  dm2000minorLowRelAttenSetting Float
  dm2000currentValueRelAttenSetting Float
  dm2000stateFlagRelAttenSetting INTEGER
  dm2000minValueRelAttenSetting Float
  dm2000maxValueRelAttenSetting Float
  dm2000alarmStateRelAttenSetting INTEGER
  dm2000labelOptPower DisplayString Size(0..80)
  dm2000uomOptPower DisplayString Size(0..80)
  dm2000majorHighOptPower Float
  dm2000majorLowOptPower Float
  dm2000minorHighOptPower Float
  dm2000minorLowOptPower Float
  dm2000currentValueOptPower Float
  dm2000stateFlagOptPower INTEGER
  dm2000minValueOptPower Float
  dm2000maxValueOptPower Float
  dm2000alarmStateOptPower INTEGER
  dm2000labelLaserBias DisplayString Size(0..80)
  dm2000uomLaserBias DisplayString Size(0..80)
  dm2000majorHighLaserBias Float
  dm2000majorLowLaserBias Float
  dm2000minorHighLaserBias Float
  dm2000minorLowLaserBias Float
  dm2000currentValueLaserBias Float
  dm2000stateFlagLaserBias INTEGER
  dm2000minValueLaserBias Float
  dm2000maxValueLaserBias Float
  dm2000alarmStateLaserBias INTEGER
  dm2000labelTecCurrent DisplayString Size(0..80)
  dm2000uomTecCurrent DisplayString Size(0..80)
  dm2000majorHighTecCurrent Float
  dm2000majorLowTecCurrent Float
  dm2000minorHighTecCurrent Float
  dm2000minorLowTecCurrent Float
  dm2000currentValueTecCurrent Float
  dm2000stateFlagTecCurrent INTEGER
  dm2000minValueTecCurrent Float
  dm2000maxValueTecCurrent Float
  dm2000alarmStateTecCurrent INTEGER
  dm2000labelLaserTemp DisplayString Size(0..80)
  dm2000uomLaserTemp DisplayString Size(0..80)
  dm2000majorHighLaserTemp Float
  dm2000majorLowLaserTemp Float
  dm2000minorHighLaserTemp Float
  dm2000minorLowLaserTemp Float
  dm2000currentValueLaserTemp Float
  dm2000stateFlagLaserTemp INTEGER
  dm2000minValueLaserTemp Float
  dm2000maxValueLaserTemp Float
  dm2000alarmStateLaserTemp INTEGER
  dm2000labelModuleTemp DisplayString Size(0..80)
  dm2000uomModuleTemp DisplayString Size(0..80)
  dm2000majorHighModuleTemp Float
  dm2000majorLowModuleTemp Float
  dm2000minorHighModuleTemp Float
  dm2000minorLowModuleTemp Float
  dm2000currentValueModuleTemp Float
  dm2000stateFlagModuleTemp INTEGER
  dm2000minValueModuleTemp Float
  dm2000maxValueModuleTemp Float
  dm2000alarmStateModuleTemp INTEGER
  dm2000labelFanCurrent DisplayString Size(0..80)
  dm2000uomFanCurrent DisplayString Size(0..80)
  dm2000majorHighFanCurrent Float
  dm2000majorLowFanCurrent Float
  dm2000minorHighFanCurrent Float
  dm2000minorLowFanCurrent Float
  dm2000currentValueFanCurrent Float
  dm2000stateFlagFanCurrent INTEGER
  dm2000minValueFanCurrent Float
  dm2000maxValueFanCurrent Float
  dm2000alarmStateFanCurrent INTEGER
  dm2000label12Volt DisplayString Size(0..80)
  dm2000uom12Volt DisplayString Size(0..80)
  dm2000majorHigh12Volt Float
  dm2000majorLow12Volt Float
  dm2000minorHigh12Volt Float
  dm2000minorLow12Volt Float
  dm2000currentValue12Volt Float
  dm2000stateFlag12Volt INTEGER
  dm2000minValue12Volt Float
  dm2000maxValue12Volt Float
  dm2000alarmState12Volt INTEGER

Gx2dm2000DigitalEntry  
SEQUENCE    
  gx2dm2000DigitalTableIndex INTEGER
  dm2000labelRfInput DisplayString Size(0..80)
  dm2000enumRfInput DisplayString Size(0..80)
  dm2000valueRfInput INTEGER
  dm2000stateflagRfInput INTEGER
  dm2000labelOptOutput DisplayString Size(0..80)
  dm2000enumOptOutput DisplayString Size(0..80)
  dm2000valueOptOutput INTEGER
  dm2000stateflagOptOutput INTEGER
  dm2000labelLaserMode DisplayString Size(0..80)
  dm2000enumLaserMode DisplayString Size(0..80)
  dm2000valueLaserMode INTEGER
  dm2000stateflagLaserMode INTEGER
  dm2000labelLaserSecMode DisplayString Size(0..80)
  dm2000enumLaserSecMode DisplayString Size(0..80)
  dm2000valueLaserSecMode INTEGER
  dm2000stateflagLaserSecMode INTEGER
  dm2000labelVideoOffset DisplayString Size(0..80)
  dm2000enumVideoOffset DisplayString Size(0..80)
  dm2000valueVideoOffset INTEGER
  dm2000stateflagVideoOffset INTEGER
  dm2000labelFactoryDefault DisplayString Size(0..80)
  dm2000enumFactoryDefault DisplayString Size(0..80)
  dm2000valueFactoryDefault INTEGER
  dm2000stateflagFactoryDefault INTEGER
  dm2000labelFiberLength DisplayString Size(0..80)
  dm2000enumFiberLength DisplayString Size(0..80)
  dm2000valueFiberLength INTEGER
  dm2000stateflagFiberLength INTEGER
  dm2000labelWavelengthOffset DisplayString Size(0..80)
  dm2000enumWavelengthOffset DisplayString Size(0..80)
  dm2000valueWavelengthOffset INTEGER
  dm2000stateflagWavelengthOffset INTEGER

Gx2dm2000StatusEntry  
SEQUENCE    
  gx2dm2000StatusTableIndex INTEGER
  dm2000labelBoot DisplayString Size(0..80)
  dm2000valueBoot INTEGER
  dm2000stateflagBoot INTEGER
  dm2000labelFlash DisplayString Size(0..80)
  dm2000valueFlash INTEGER
  dm2000stateflagFlash INTEGER
  dm2000labelFactoryDataCRC DisplayString Size(0..80)
  dm2000valueFactoryDataCRC INTEGER
  dm2000stateflagFactoryDataCRC INTEGER
  dm2000labelLaserDataCRC DisplayString Size(0..80)
  dm2000valueLaserDataCRC INTEGER
  dm2000stateflagLaserDataCRC INTEGER
  dm2000labelAlarmDataCrc DisplayString Size(0..80)
  dm2000valueAlarmDataCrc INTEGER
  dm2000stateflagAlarmDataCrc INTEGER
  dm2000labelHWStatus DisplayString Size(0..80)
  dm2000valueHWStatus INTEGER
  dm2000stateflagHWStatus INTEGER
  dm2000labelRFInputStatus DisplayString Size(0..80)
  dm2000valueRFInputStatus INTEGER
  dm2000stateflagRFInputStatus INTEGER

Gx2dm2000FactoryEntry  
SEQUENCE    
  gx2dm2000FactoryTableIndex INTEGER
  dm2000bootControlByteValue INTEGER
  dm2000bootStatusByteValue INTEGER
  dm2000bank1CRCValue INTEGER
  dm2000bank2CRCValue INTEGER
  dm2000prgEEPROMByteValue INTEGER
  dm2000factoryCRCValue INTEGER
  dm2000calculateCRCValue INTEGER
  dm2000hourMeterValue INTEGER
  dm2000flashPrgCntAValue INTEGER
  dm2000flashPrgCntBValue INTEGER
  dm2000flashBankARevValue DisplayString Size(0..80)
  dm2000flashBankBRevValue DisplayString Size(0..80)

Gx2Dm2000HoldTimeEntry  
SEQUENCE    
  gx2Dm2000HoldTimeTableIndex INTEGER
  gx2Dm2000HoldTimeSpecIndex INTEGER
  gx2Dm2000HoldTimeData INTEGER

Defined Values

gx2dm2000Descriptor 1.3.6.1.4.1.1166.6.1.2.34.1
OBJECT IDENTIFIER    

gx2dm2000AnalogTable 1.3.6.1.4.1.1166.6.1.2.34.2
This table contains gx2Dm2000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2dm2000AnalogEntry

gx2dm2000AnalogEntry 1.3.6.1.4.1.1166.6.1.2.34.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2dm2000AnalogEntry  

gx2dm2000DigitalTable 1.3.6.1.4.1.1166.6.1.2.34.3
This table contains gx2Dm2000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2dm2000DigitalEntry

gx2dm2000DigitalEntry 1.3.6.1.4.1.1166.6.1.2.34.3.2
This list contains digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2dm2000DigitalEntry  

gx2dm2000StatusTable 1.3.6.1.4.1.1166.6.1.2.34.4
This table contains gx2Dm2000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2dm2000StatusEntry

gx2dm2000StatusEntry 1.3.6.1.4.1.1166.6.1.2.34.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2dm2000StatusEntry  

gx2dm2000FactoryTable 1.3.6.1.4.1.1166.6.1.2.34.5
This table contains gx2Dm2000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2dm2000FactoryEntry

gx2dm2000FactoryEntry 1.3.6.1.4.1.1166.6.1.2.34.5.4
This list contains Factory parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2dm2000FactoryEntry  

gx2Dm2000HoldTimeTable 1.3.6.1.4.1.1166.6.1.2.34.6
This table contains gx2Dm2000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Dm2000HoldTimeEntry

gx2Dm2000HoldTimeEntry 1.3.6.1.4.1.1166.6.1.2.34.6.5
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Dm2000HoldTimeEntry  

gx2dm2000AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.34.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm2000labelOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.2
The value of this object provides the label of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000uomOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.3
The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000majorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.4
The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000majorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.5
The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.6
The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.7
The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000currentValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.8
The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000stateFlagOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.9
The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000minValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.10
The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000maxValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.11
The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000alarmStateOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.34.2.1.12
The value of this object provides the curent alarm state of the Offset Monitor Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm2000labelOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.13
The value of this object provides the label of the Offset Control Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000uomOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.14
The value of this object provides the label of the Offset Control Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000majorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.15
The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000majorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.16
The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.17
The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.18
The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000currentValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.19
The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

dm2000stateFlagOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.20
The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000minValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.21
The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000maxValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.22
The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000alarmStateOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.34.2.1.23
The value of this object provides the curent alarm state of the Offset Control Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm2000labelRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.24
The value of this object provides the label of the Attenuator Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000uomRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.25
The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000majorHighRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.26
The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000majorLowRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.27
The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorHighRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.28
The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorLowRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.29
The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000currentValueRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.30
The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

dm2000stateFlagRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.31
The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000minValueRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.32
The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000maxValueRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.33
The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000alarmStateRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.34.2.1.34
The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm2000labelOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.35
The value of this object provides the label of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000uomOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.36
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000majorHighOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.37
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000majorLowOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.38
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorHighOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.39
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorLowOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.40
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000currentValueOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.41
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000stateFlagOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.42
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000minValueOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.43
The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000maxValueOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.44
The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000alarmStateOptPower 1.3.6.1.4.1.1166.6.1.2.34.2.1.45
The value of this object provides the curent alarm state of the Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm2000labelLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.46
The value of this object provides the label of the Laser Bias Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000uomLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.47
The value of this object provides the Unit of Measure of the Laser Bias Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000majorHighLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.48
The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000majorLowLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.49
The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorHighLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.50
The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorLowLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.51
The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000currentValueLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.52
The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000stateFlagLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.53
The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000minValueLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.54
The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000maxValueLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.55
The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000alarmStateLaserBias 1.3.6.1.4.1.1166.6.1.2.34.2.1.56
The value of this object provides the curent alarm state of the Laser Bias Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm2000labelTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.57
The value of this object provides the label of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000uomTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.58
The value of this object provides the Unit of Measure of the TEC Current Analog parameter..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000majorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.59
The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000majorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.60
The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.61
The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.62
The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000currentValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.63
The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000stateFlagTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.64
The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000minValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.65
The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000maxValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.66
The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000alarmStateTecCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.67
The value of this object provides the curent alarm state of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm2000labelLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.68
The value of this object provides the label of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000uomLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.69
The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000majorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.70
The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000majorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.71
The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.72
The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.73
The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000currentValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.74
The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000stateFlagLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.75
The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000minValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.76
The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000maxValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.77
The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000alarmStateLaserTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.78
The value of this object provides the curent alarm state of the Laser Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm2000labelModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.79
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000uomModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.80
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000majorHighModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.81
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000majorLowModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.82
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorHighModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.83
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorLowModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.84
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000currentValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.85
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000stateFlagModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.86
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000minValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.87
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000maxValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.88
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000alarmStateModuleTemp 1.3.6.1.4.1.1166.6.1.2.34.2.1.89
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm2000labelFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.90
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000uomFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.91
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000majorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.92
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000majorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.93
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.94
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.95
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000currentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.96
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000stateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.97
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000minValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.98
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000maxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.99
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000alarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.34.2.1.100
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dm2000label12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.101
The value of this object provides the label of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000uom12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.102
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000majorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.103
The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000majorLow12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.104
The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.105
The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000minorLow12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.106
The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000currentValue12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.107
The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000stateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.108
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000minValue12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.109
The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000maxValue12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.110
The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dm2000alarmState12Volt 1.3.6.1.4.1.1166.6.1.2.34.2.1.111
The value of this object provides the curent alarm state of the 12v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2dm2000DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.34.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm2000labelRfInput 1.3.6.1.4.1.1166.6.1.2.34.3.2.2
The value of this object provides the label of the RF Input Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000enumRfInput 1.3.6.1.4.1.1166.6.1.2.34.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueRfInput 1.3.6.1.4.1.1166.6.1.2.34.3.2.4
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm2000stateflagRfInput 1.3.6.1.4.1.1166.6.1.2.34.3.2.5
The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelOptOutput 1.3.6.1.4.1.1166.6.1.2.34.3.2.6
The value of this object provides the label of the Optical Output Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000enumOptOutput 1.3.6.1.4.1.1166.6.1.2.34.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueOptOutput 1.3.6.1.4.1.1166.6.1.2.34.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm2000stateflagOptOutput 1.3.6.1.4.1.1166.6.1.2.34.3.2.9
The value of this object provides the dm2000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelLaserMode 1.3.6.1.4.1.1166.6.1.2.34.3.2.10
The value of this object provides the label of the Laser Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000enumLaserMode 1.3.6.1.4.1.1166.6.1.2.34.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueLaserMode 1.3.6.1.4.1.1166.6.1.2.34.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER preset(1), set(2), setEquate(3), manual(4), manualEquate(5)  

dm2000stateflagLaserMode 1.3.6.1.4.1.1166.6.1.2.34.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelLaserSecMode 1.3.6.1.4.1.1166.6.1.2.34.3.2.14
The value of this object provides the label of the Laser Secondary Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000enumLaserSecMode 1.3.6.1.4.1.1166.6.1.2.34.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueLaserSecMode 1.3.6.1.4.1.1166.6.1.2.34.3.2.16
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cw(1), video(2)  

dm2000stateflagLaserSecMode 1.3.6.1.4.1.1166.6.1.2.34.3.2.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelVideoOffset 1.3.6.1.4.1.1166.6.1.2.34.3.2.18
The value of this object provides the label of the Video Offset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000enumVideoOffset 1.3.6.1.4.1.1166.6.1.2.34.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueVideoOffset 1.3.6.1.4.1.1166.6.1.2.34.3.2.20
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER minus2dB(1), minus3dB(2), minus4dB(3), minus5dB(4)  

dm2000stateflagVideoOffset 1.3.6.1.4.1.1166.6.1.2.34.3.2.21
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.34.3.2.22
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000enumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.34.3.2.23
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.34.3.2.24
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dm2000stateflagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.34.3.2.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelFiberLength 1.3.6.1.4.1.1166.6.1.2.34.3.2.26
The value of this object provides the label for the Fiber Length Digital parameter .
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000enumFiberLength 1.3.6.1.4.1.1166.6.1.2.34.3.2.27
The value of this object represents the Enumeration values possible for the Digital parameter. The range for fiber length selection is from 0 to 60km, where 0km is represented with a 1, and 60 with a 61.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueFiberLength 1.3.6.1.4.1.1166.6.1.2.34.3.2.28
The value of this object is the current value of the parameter. It is used to set fiber length. The value range for this object is: 1 to 61. Where 1 = 0Km and 61 = 60Km
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

dm2000stateflagFiberLength 1.3.6.1.4.1.1166.6.1.2.34.3.2.29
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelWavelengthOffset 1.3.6.1.4.1.1166.6.1.2.34.3.2.30
The value of this object provides the label for the Wavelength Offset Digital parameter .
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000enumWavelengthOffset 1.3.6.1.4.1.1166.6.1.2.34.3.2.31
The value of this object represents the Enumeration values possible for this Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueWavelengthOffset 1.3.6.1.4.1.1166.6.1.2.34.3.2.32
The value of this object is the current value of the parameter. It is used to select a Narrowcast or Full Spectrum application.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER narrowcast(1), fullSpectrum(2)  

dm2000stateflagWavelengthOffset 1.3.6.1.4.1.1166.6.1.2.34.3.2.33
The value of this object provides the state of the the Wavelength Offset parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2dm2000StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.34.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm2000labelBoot 1.3.6.1.4.1.1166.6.1.2.34.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueBoot 1.3.6.1.4.1.1166.6.1.2.34.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm2000stateflagBoot 1.3.6.1.4.1.1166.6.1.2.34.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelFlash 1.3.6.1.4.1.1166.6.1.2.34.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueFlash 1.3.6.1.4.1.1166.6.1.2.34.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm2000stateflagFlash 1.3.6.1.4.1.1166.6.1.2.34.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.34.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.34.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm2000stateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.34.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.34.4.3.11
The value of this object provides the label of the Laser Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.34.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm2000stateflagLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.34.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.34.4.3.14
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.34.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm2000stateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.34.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelHWStatus 1.3.6.1.4.1.1166.6.1.2.34.4.3.17
The value of this object provides the label of the Laser Drive Level Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueHWStatus 1.3.6.1.4.1.1166.6.1.2.34.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm2000stateflagHWStatus 1.3.6.1.4.1.1166.6.1.2.34.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dm2000labelRFInputStatus 1.3.6.1.4.1.1166.6.1.2.34.4.3.20
The value of this object provides the label of the RF Input Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000valueRFInputStatus 1.3.6.1.4.1.1166.6.1.2.34.4.3.21
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dm2000stateflagRFInputStatus 1.3.6.1.4.1.1166.6.1.2.34.4.3.22
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2dm2000FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.34.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

dm2000bootControlByteValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm2000bootStatusByteValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm2000bank1CRCValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm2000bank2CRCValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm2000prgEEPROMByteValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm2000factoryCRCValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm2000calculateCRCValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.8
This object indicates which of the Emnums will have the CRC calculated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), laserData(2), alarm(3)  

dm2000hourMeterValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm2000flashPrgCntAValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.10
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm2000flashPrgCntBValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dm2000flashBankARevValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.12
This object provides the revision of flash bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dm2000flashBankBRevValue 1.3.6.1.4.1.1166.6.1.2.34.5.4.13
This object provides the revision of flash bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gx2Dm2000HoldTimeTableIndex 1.3.6.1.4.1.1166.6.1.2.34.6.5.1
The value of this object is the index of the data object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2Dm2000HoldTimeSpecIndex 1.3.6.1.4.1.1166.6.1.2.34.6.5.2
The value of this object identifies the index of the alarm object to be modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2Dm2000HoldTimeData 1.3.6.1.4.1.1166.6.1.2.34.6.5.3
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

trapDM2000ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapDM2000ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapDM2000RFInputAlarm 3
This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM2000RFOverloadAlarm 4
This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM2000RFOffsetAlarm 5
This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM2000OpticalPowerAlarm 6
This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM2000LaserBiasAlarm 7
This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM2000LaserTempAlarm 8
This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM2000TECCurrentAlarm 9
This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM2000FanCurrentAlarm 10
This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM200012vAlarm 11
This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapDM2000ModuleTempAlarm 12
This trap is issued when the Laser Module Temperature goes out of range.
TRAP-TYPE    

trapDM2000FlashAlarm 13
This trap is issued when the Laser Modules detects an error during Flash memory operations.
TRAP-TYPE    

trapDM2000LaserBiasCntLoopAlarm 14
This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation.
TRAP-TYPE    

trapDM2000BankBootAlarm 15
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapDM2000LaserBiasCntLoopInitAlarm 16
This trap is issued when the Laser Bias Control loop init fails.
TRAP-TYPE    

trapDM2000RFParamInitAlarm 17
This trap is issued when the RF parameter Init fails.
TRAP-TYPE    

trapDM2000TECParamInitAlarm 18
This trap is issued when the TEC Parameter Init fails.
TRAP-TYPE    

trapDM2000AttnTableInitAlarm 19
This trap is issued when the Attenuator Table Init fails.
TRAP-TYPE    

trapDM2000PowerMeterTableInitAlarm 20
This trap is issued when the Power Meter Table Init fails.
TRAP-TYPE    

trapDM2000LaserDataCRCAlarm 21
This trap is issued when the Laser Data CRC is incorrect.
TRAP-TYPE    

trapDM2000AlarmDataCRCAlarm 22
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapDM2000FactoryDataCRCAlarm 23
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapDM2000UserRFOffAlarm 24
This trap is issued when the the User RF is turned off.
TRAP-TYPE    

trapDM2000UserOpticalOffAlarm 25
This trap is issued when the User Optical Power is turned off.
TRAP-TYPE    

trapDM2000ResetFactoryDefaultAlarm 26
This trap is issued when the Factory Default Reset occurs.
TRAP-TYPE