OG-STATUSv2-MIB

File: OG-STATUSv2-MIB.mib (98820 bytes)

Imported modules

OG-SMI-MIB SNMPv2-SMI SNMPv2-CONF
SNMPv2-TC

Imported symbols

opengear MODULE-IDENTITY NOTIFICATION-TYPE
OBJECT-TYPE Integer32 Unsigned32
Counter32 Counter64 MODULE-COMPLIANCE
NOTIFICATION-GROUP OBJECT-GROUP DateAndTime
DisplayString

Defined Types

SerialPortEntry  
SEQUENCE    
  ogSerialPortIndex Integer32
  ogSerialPortLabel DisplayString
  ogSerialPortSpeed Integer32
  ogSerialPortDataBits Integer32
  ogSerialPortParity INTEGER
  ogSerialPortStopBits INTEGER
  ogSerialPortFlowControl INTEGER
  ogSerialPortMode INTEGER
  ogSerialPortLogLevel INTEGER
  ogSerialPortRxBytes Counter64
  ogSerialPortTxBytes Counter64
  ogSerialPortFramingErrors Counter64
  ogSerialPortParityErrors Counter64
  ogSerialPortOverrunErrors Counter64
  ogSerialPortBreaks Counter64
  ogSerialPortDCD INTEGER
  ogSerialPortDTR INTEGER
  ogSerialPortDSR INTEGER
  ogSerialPortCTS INTEGER
  ogSerialPortRTS INTEGER

SerialUserEntry  
SEQUENCE    
  ogSerialUserIndex Integer32
  ogSerialUserStartTime DateAndTime
  ogSerialUserPort Integer32
  ogSerialUserLabel DisplayString
  ogSerialUserName DisplayString

HostEntry  
SEQUENCE    
  ogHostIndex Integer32
  ogHostName DisplayString
  ogHostIpV4Address DisplayString
  ogHostIpV6Address DisplayString

HostServiceEntry  
SEQUENCE    
  ogHostServiceIndex Integer32
  ogHostServiceHost OBJECT IDENTIFIER
  ogHostServiceType INTEGER
  ogHostServicePort Unsigned32
  ogHostServiceStatus INTEGER
  ogHostServiceCounter Counter32

HostUserEntry  
SEQUENCE    
  ogHostUserIndex Integer32
  ogHostUserHost OBJECT IDENTIFIER
  ogHostUserStartTime DateAndTime
  ogHostUserAddress DisplayString
  ogHostUserHostName DisplayString
  ogHostUserName DisplayString

WebUserEntry  
SEQUENCE    
  ogWebUserIndex Integer32
  ogWebUserStartTime DateAndTime
  ogWebUserName DisplayString
  ogWebUserSourceAddress DisplayString
  ogWebUserSourcePort Integer32

EmdEntry  
SEQUENCE    
  ogEmdIndex Integer32
  ogEmdName DisplayString
  ogEmdDescription DisplayString
  ogEmdEnabled INTEGER
  ogEmdLogEnabled INTEGER
  ogEmdConnectType INTEGER
  ogEmdTemperatureTotal Counter32
  ogEmdHumidityTotal Counter32
  ogEmdDioInputTotal Counter32

EmdTemperatureEntry  
SEQUENCE    
  ogEmdTemperatureIndex Integer32
  ogEmdTemperatureEmd OBJECT IDENTIFIER
  ogEmdTemperatureName DisplayString
  ogEmdTemperatureDescription DisplayString
  ogEmdTemperatureValue Integer32
  ogEmdTemperatureCounter Counter32

EmdHumidityEntry  
SEQUENCE    
  ogEmdHumidityIndex Integer32
  ogEmdHumidityEmd OBJECT IDENTIFIER
  ogEmdHumidityName DisplayString
  ogEmdHumidityDescription DisplayString
  ogEmdHumidityValue Integer32
  ogEmdHumidityCounter Counter32

EmdDioEntry  
SEQUENCE    
  ogEmdDioIndex Integer32
  ogEmdDioEmd OBJECT IDENTIFIER
  ogEmdDioName DisplayString
  ogEmdDioDescription DisplayString
  ogEmdDioType INTEGER
  ogEmdDioDirection INTEGER
  ogEmdDioState INTEGER
  ogEmdDioTriggerMode INTEGER
  ogEmdDioCounter Counter32

NetInterfaceEntry  
SEQUENCE    
  ogNetInterfaceIndex Integer32
  ogNetInterfaceName DisplayString
  ogNetInterfaceType INTEGER
  ogNetInterfaceState INTEGER

PowerSupplyEntry  
SEQUENCE    
  ogPowerSupplyIndex Integer32
  ogPowerSupplyName DisplayString
  ogPowerSupplyInputVoltage Integer32
  ogPowerSupplyOutputCurrent Integer32
  ogPowerSupplyTemperature Integer32

UpsEntry  
SEQUENCE    
  ogUpsIndex Integer32
  ogUpsName DisplayString
  ogUpsDescription DisplayString
  ogUpsType DisplayString
  ogUpsLogEnabled INTEGER
  ogUpsConnectType INTEGER
  ogUpsState INTEGER
  ogUpsTemperature Integer32
  ogUpsHumidity Integer32
  ogUpsBatteryState INTEGER
  ogUpsBatteryRunTime Integer32
  ogUpsBatteryRunTimeLow Integer32
  ogUpsBatteryRunTimeRestart Integer32
  ogUpsBatteryCharge Integer32
  ogUpsBatteryVoltage Integer32
  ogUpsBatteryNominalVoltage Integer32
  ogUpsBatteryCurrent Integer32
  ogUpsBatteryNominalCurrent Integer32
  ogUpsBatteryTemperature Integer32
  ogUpsInputFrequency Integer32
  ogUpsInputNominalFrequency Integer32
  ogUpsInputVoltage Integer32
  ogUpsInputNominalVoltage Integer32
  ogUpsInputCurrent Integer32
  ogUpsInputNominalCurrent Integer32
  ogUpsOutputFrequency Integer32
  ogUpsOutputNominalFrequency Integer32
  ogUpsOutputVoltage Integer32
  ogUpsOutputNominalVoltage Integer32
  ogUpsOutputCurrent Integer32
  ogUpsOutputNominalCurrent Integer32
  ogUpsOutputLoad Integer32
  ogUpsOutputPower Integer32
  ogUpsOutputTruePower Integer32
  ogUpsCounter Counter32

RpcEntry  
SEQUENCE    
  ogRpcIndex Integer32
  ogRpcName DisplayString
  ogRpcDescription DisplayString
  ogRpcType DisplayString
  ogRpcLogEnabled INTEGER
  ogRpcOutletTotal Counter32
  ogRpcMaxTemperature Integer32
  ogRpcConnectType INTEGER
  ogRpcInputFrequency Integer32
  ogRpcInputVoltage Integer32
  ogRpcInputCurrent Integer32
  ogRpcCounter Counter32

RpcOutletEntry  
SEQUENCE    
  ogRpcOutletIndex Integer32
  ogRpcOutletRpc OBJECT IDENTIFIER
  ogRpcOutletName DisplayString
  ogRpcOutletState INTEGER
  ogRpcOutletFrequency Integer32
  ogRpcOutletVoltage Integer32
  ogRpcOutletCurrent Integer32
  ogRpcOutletLoad Integer32

CellModemEntry  
SEQUENCE    
  ogCellModemIndex Integer32
  ogCellModemVendor DisplayString
  ogCellModemModel DisplayString
  ogCellModemEnabled INTEGER
  ogCellModemConnected INTEGER
  ogCellModemNetwork DisplayString
  ogCellModemRegistered INTEGER
  ogCellModemTower Integer32
  ogCellModemRadioTechnology INTEGER
  ogCellModemApn DisplayString
  ogCellModem3gRssi Integer32
  ogCellModem4gRssi Integer32
  ogCellModemSessionTime Counter32
  ogCellModemSelectedSimCard Counter32
  ogCellModemTemperature Integer32
  ogCellModemCounter Counter32

WifiClientEntry  
SEQUENCE    
  ogWifiClientIndex Integer32
  ogWifiClientInterface DisplayString
  ogWifiClientEnabled INTEGER
  ogWifiClientEssid DisplayString
  ogWifiClientIeeeMode INTEGER
  ogWifiClientMode INTEGER
  ogWifiClientFrequency Unsigned32
  ogWifiClientApMac DisplayString
  ogWifiClientBitRate Unsigned32
  ogWifiClientTxPower Integer32
  ogWifiClientLinkQuality Unsigned32
  ogWifiClientRssi Integer32
  ogWifiClientRxInvalidNwid Counter32
  ogWifiClientRxInvalidCrypt Counter32
  ogWifiClientRxInvalidFrag Counter32
  ogWifiClientRxInvalidRetries Counter32
  ogWifiClientRxInvalidMisc Counter32
  ogWifiClientMissedBeacon Counter32
  ogWifiClientCounter Counter32

WifiApEntry  
SEQUENCE    
  ogWifiApIndex Integer32
  ogWifiApInterface DisplayString
  ogWifiApEnabled INTEGER
  ogWifiApSsid DisplayString
  ogWifiApIeeeMode INTEGER
  ogWifiApFrequency Unsigned32
  ogWifiApTxPower Integer32
  ogWifiApCounter Counter32

WifiApClientEntry  
SEQUENCE    
  ogWifiApClientIndex Integer32
  ogWifiApClientAp OBJECT IDENTIFIER
  ogWifiApClientMac DisplayString
  ogWifiApClientInactiveTime Counter32
  ogWifiApClientRxBytes Counter32
  ogWifiApClientRxPackets Counter32
  ogWifiApClientTxBytes Counter32
  ogWifiApClientTxPackets Counter32
  ogWifiApClientRssi Integer32
  ogWifiApClientTxBitRate Unsigned32

CheckEntry  
SEQUENCE    
  ogCheckIndex Integer32
  ogCheckName DisplayString
  ogCheckRepeatTimeout Integer32
  ogCheckResetTimeout Integer32
  ogCheckType INTEGER
  ogCheckTriggerActions Counter32
  ogCheckResolveActions Counter32

CheckDeviceEntry  
SEQUENCE    
  ogCheckDeviceIndex Integer32
  ogCheckDeviceCheck OBJECT IDENTIFIER
  ogCheckDeviceName DisplayString
  ogCheckDeviceRef DisplayString

AlarmLogEntry  
SEQUENCE    
  ogAlarmLogIndex Integer32
  ogAlarmEventId Integer32
  ogAlarmName DisplayString
  ogAlarmCheck Integer32
  ogAlarmInstance Integer32
  ogAlarmTime DateAndTime
  ogAlarmType INTEGER
  ogAlarmSummary DisplayString
  ogAlarmDevice DisplayString
  ogAlarmUser DisplayString
  ogAlarmTriggerValue Integer32
  ogAlarmCurrentValue Integer32
  ogAlarmPreviousValue Integer32
  ogAlarmState INTEGER

CurrentAlarmEntry  
SEQUENCE    
  ogCurrentAlarmIndex Integer32
  ogCurrentAlarmEventId Integer32
  ogCurrentAlarmName DisplayString
  ogCurrentAlarmCheck Integer32
  ogCurrentAlarmInstance Integer32
  ogCurrentAlarmTime DateAndTime
  ogCurrentAlarmType INTEGER
  ogCurrentAlarmSummary DisplayString
  ogCurrentAlarmDevice DisplayString
  ogCurrentAlarmUser DisplayString
  ogCurrentAlarmTriggerValue Integer32
  ogCurrentAlarmCurrentValue Integer32
  ogCurrentAlarmPreviousValue Integer32
  ogCurrentAlarmState INTEGER

Defined Values

ogStatus2 1.3.6.1.4.1.25049.17
Opengear extended status and alert MIB
MODULE-IDENTITY    

ogSystem 1.3.6.1.4.1.25049.17.1
OBJECT IDENTIFIER    

ogFirmwareVersion 1.3.6.1.4.1.25049.17.1.1
The current device firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

ogSerialNumber 1.3.6.1.4.1.25049.17.1.2
The current serial number (if applicable).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

ogSerialPortTable 1.3.6.1.4.1.25049.17.2
The devices serial port status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SerialPortEntry

ogSerialPortEntry 1.3.6.1.4.1.25049.17.2.1
A serial port status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SerialPortEntry  

ogSerialPortIndex 1.3.6.1.4.1.25049.17.2.1.1
Index within the serial port table of this status
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogSerialPortLabel 1.3.6.1.4.1.25049.17.2.1.2
Serial port descriptive name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

ogSerialPortSpeed 1.3.6.1.4.1.25049.17.2.1.3
Serial port speed in bits per second
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogSerialPortDataBits 1.3.6.1.4.1.25049.17.2.1.4
Serial port character size
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogSerialPortParity 1.3.6.1.4.1.25049.17.2.1.5
Serial port parity
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3), mark(4), space(5)  

ogSerialPortStopBits 1.3.6.1.4.1.25049.17.2.1.6
Serial port number of stop bits
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2), oneAndAHalf(3)  

ogSerialPortFlowControl 1.3.6.1.4.1.25049.17.2.1.7
Serial port flow control type
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), hardware(2), software(3)  

ogSerialPortMode 1.3.6.1.4.1.25049.17.2.1.8
Serial port operational mode type
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), console(2), sdt(3), terminal(4), bridge(5)  

ogSerialPortLogLevel 1.3.6.1.4.1.25049.17.2.1.9
Serial port logging level
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), connect(2), inputAndOutput(3), inputOnly(4), outputOnly(5)  

ogSerialPortRxBytes 1.3.6.1.4.1.25049.17.2.1.10
Serial port bytes received
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ogSerialPortTxBytes 1.3.6.1.4.1.25049.17.2.1.11
Serial port bytes transmitted
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ogSerialPortFramingErrors 1.3.6.1.4.1.25049.17.2.1.12
Serial port framing error total.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ogSerialPortParityErrors 1.3.6.1.4.1.25049.17.2.1.13
Serial port parity error total.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ogSerialPortOverrunErrors 1.3.6.1.4.1.25049.17.2.1.14
Serial port Overrun Error total.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ogSerialPortBreaks 1.3.6.1.4.1.25049.17.2.1.15
Serial port break total
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ogSerialPortDCD 1.3.6.1.4.1.25049.17.2.1.16
The status of the DCD signal.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogSerialPortDTR 1.3.6.1.4.1.25049.17.2.1.17
The status of the DTR signal.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogSerialPortDSR 1.3.6.1.4.1.25049.17.2.1.18
The status of the DSR signal.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogSerialPortCTS 1.3.6.1.4.1.25049.17.2.1.19
The status of the CTS signal.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogSerialPortRTS 1.3.6.1.4.1.25049.17.2.1.20
The status of the RTS signal.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogSerialUserTable 1.3.6.1.4.1.25049.17.3
This entity's serial port users table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SerialUserEntry

ogSerialUserEntry 1.3.6.1.4.1.25049.17.3.1
A user logged in on the serial port
Status: current Access: not-accessible
OBJECT-TYPE    
  SerialUserEntry  

ogSerialUserIndex 1.3.6.1.4.1.25049.17.3.1.1
Index within the serial port active users table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogSerialUserStartTime 1.3.6.1.4.1.25049.17.3.1.2
The time and date the user session started.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

ogSerialUserPort 1.3.6.1.4.1.25049.17.3.1.3
Serial port number
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogSerialUserLabel 1.3.6.1.4.1.25049.17.3.1.4
The readable label for the serial port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

ogSerialUserName 1.3.6.1.4.1.25049.17.3.1.5
The name of the user logged in on the port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

ogHostTable 1.3.6.1.4.1.25049.17.4
A table of monitored network hosts.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HostEntry

ogHostEntry 1.3.6.1.4.1.25049.17.4.1
A monitored network host.
Status: current Access: not-accessible
OBJECT-TYPE    
  HostEntry  

ogHostIndex 1.3.6.1.4.1.25049.17.4.1.1
Index within the network host active users table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogHostName 1.3.6.1.4.1.25049.17.4.1.2
The name of this monitored network host.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ogHostIpV4Address 1.3.6.1.4.1.25049.17.4.1.3
The IPv4 Address of this monitored network host.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ogHostIpV6Address 1.3.6.1.4.1.25049.17.4.1.4
The IPv6 Address of this monitored network host.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ogHostServiceTable 1.3.6.1.4.1.25049.17.5
A table of services belonging to a monitored host.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HostServiceEntry

ogHostServiceEntry 1.3.6.1.4.1.25049.17.5.1
A monitored host service.
Status: current Access: not-accessible
OBJECT-TYPE    
  HostServiceEntry  

ogHostServiceIndex 1.3.6.1.4.1.25049.17.5.1.1
Index within the RPC outlet table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogHostServiceHost 1.3.6.1.4.1.25049.17.5.1.2
The monitored host this service belongs to
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ogHostServiceType 1.3.6.1.4.1.25049.17.5.1.3
The type of service this is.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tcp(1), udp(2)  

ogHostServicePort 1.3.6.1.4.1.25049.17.5.1.4
The TCP Port this service is on.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

ogHostServiceStatus 1.3.6.1.4.1.25049.17.5.1.5
The availabalilty of this service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), available(2), unavailable(3)  

ogHostServiceCounter 1.3.6.1.4.1.25049.17.5.1.6
The number of alerts related to this service.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogHostUserTable 1.3.6.1.4.1.25049.17.6
This entity's serial port users table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HostUserEntry

ogHostUserEntry 1.3.6.1.4.1.25049.17.6.1
A user logged in on the serial port
Status: current Access: not-accessible
OBJECT-TYPE    
  HostUserEntry  

ogHostUserIndex 1.3.6.1.4.1.25049.17.6.1.1
Index within the network host active users table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogHostUserHost 1.3.6.1.4.1.25049.17.6.1.2
The monitored host this user is associated with.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ogHostUserStartTime 1.3.6.1.4.1.25049.17.6.1.3
The date and time the user session started.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

ogHostUserAddress 1.3.6.1.4.1.25049.17.6.1.4
The network host address.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

ogHostUserHostName 1.3.6.1.4.1.25049.17.6.1.5
The network host's host name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

ogHostUserName 1.3.6.1.4.1.25049.17.6.1.6
The network host's active username.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

ogWebUserTable 1.3.6.1.4.1.25049.17.7
This entity's serial port users table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WebUserEntry

ogWebUserEntry 1.3.6.1.4.1.25049.17.7.1
A user logged in on the serial port
Status: current Access: not-accessible
OBJECT-TYPE    
  WebUserEntry  

ogWebUserIndex 1.3.6.1.4.1.25049.17.7.1.1
Index within the network host active users table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogWebUserStartTime 1.3.6.1.4.1.25049.17.7.1.2
The web users session start date and time.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

ogWebUserName 1.3.6.1.4.1.25049.17.7.1.3
The web users active username.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

ogWebUserSourceAddress 1.3.6.1.4.1.25049.17.7.1.4
The web users source address.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

ogWebUserSourcePort 1.3.6.1.4.1.25049.17.7.1.5
The web users source tcp port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

ogEmdTable 1.3.6.1.4.1.25049.17.8
This devices temperature monitoring table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EmdEntry

ogEmdEntry 1.3.6.1.4.1.25049.17.8.1
EMD status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  EmdEntry  

ogEmdIndex 1.3.6.1.4.1.25049.17.8.1.1
Index within the EMD status table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogEmdName 1.3.6.1.4.1.25049.17.8.1.2
The name of the EMD device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogEmdDescription 1.3.6.1.4.1.25049.17.8.1.3
A description of the EMD device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogEmdEnabled 1.3.6.1.4.1.25049.17.8.1.4
The enabled status of the EMD
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogEmdLogEnabled 1.3.6.1.4.1.25049.17.8.1.5
The logging status of the EMD
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogEmdConnectType 1.3.6.1.4.1.25049.17.8.1.6
How the EMD device is connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER internal(1), serial(2), network(3)  

ogEmdTemperatureTotal 1.3.6.1.4.1.25049.17.8.1.7
The number of temperature sensors contained in this EMD.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogEmdHumidityTotal 1.3.6.1.4.1.25049.17.8.1.8
The number of humidity sensors contained in this EMD.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogEmdDioInputTotal 1.3.6.1.4.1.25049.17.8.1.9
The number of DIOs contained in this EMD.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogEmdTemperatureTable 1.3.6.1.4.1.25049.17.9
A table of temperature sensors belonging to EMDs
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EmdTemperatureEntry

ogEmdTemperatureEntry 1.3.6.1.4.1.25049.17.9.1
EMD status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  EmdTemperatureEntry  

ogEmdTemperatureIndex 1.3.6.1.4.1.25049.17.9.1.1
Index within the EMD status table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogEmdTemperatureEmd 1.3.6.1.4.1.25049.17.9.1.2
The EMD this temperature sensor is related to.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ogEmdTemperatureName 1.3.6.1.4.1.25049.17.9.1.3
The name of the EMD temperature sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogEmdTemperatureDescription 1.3.6.1.4.1.25049.17.9.1.4
A description of the EMD device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogEmdTemperatureValue 1.3.6.1.4.1.25049.17.9.1.5
The current temperature reading on the EMD.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogEmdTemperatureCounter 1.3.6.1.4.1.25049.17.9.1.6
Number of alerts triggered on the EMD.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogEmdHumidityTable 1.3.6.1.4.1.25049.17.10
A table of humidity sensors belonging to EMDs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EmdHumidityEntry

ogEmdHumidityEntry 1.3.6.1.4.1.25049.17.10.1
EMD Humidity sensor status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  EmdHumidityEntry  

ogEmdHumidityIndex 1.3.6.1.4.1.25049.17.10.1.1
Index within the EMD status table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogEmdHumidityEmd 1.3.6.1.4.1.25049.17.10.1.2
The EMD this humidity sensor is related to.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ogEmdHumidityName 1.3.6.1.4.1.25049.17.10.1.3
The name of the EMD.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogEmdHumidityDescription 1.3.6.1.4.1.25049.17.10.1.4
A description of the EMD device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogEmdHumidityValue 1.3.6.1.4.1.25049.17.10.1.5
The current humidity value on the EMD
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogEmdHumidityCounter 1.3.6.1.4.1.25049.17.10.1.6
Number of alerts triggered on the EMD
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogEmdDioTable 1.3.6.1.4.1.25049.17.11
Ths Digital I/O status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EmdDioEntry

ogEmdDioEntry 1.3.6.1.4.1.25049.17.11.1
Digital I/O status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  EmdDioEntry  

ogEmdDioIndex 1.3.6.1.4.1.25049.17.11.1.1
Index within the Digital I/O status table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogEmdDioEmd 1.3.6.1.4.1.25049.17.11.1.2
The EMD this Digital I/O relates to.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ogEmdDioName 1.3.6.1.4.1.25049.17.11.1.3
The ID of this Digital I/O.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogEmdDioDescription 1.3.6.1.4.1.25049.17.11.1.4
A description of this Digital I/O.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogEmdDioType 1.3.6.1.4.1.25049.17.11.1.5
Digital I/O type (TTL Input/Output or High-Voltage Output).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ttlInputOutput(1), highVoltageOutput(2)  

ogEmdDioDirection 1.3.6.1.4.1.25049.17.11.1.6
The direction of the Digital I/O (Input or Output)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER output(1), input(2)  

ogEmdDioState 1.3.6.1.4.1.25049.17.11.1.7
The electrical state value of the Digital I/O (Low or High)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER high(1), low(2)  

ogEmdDioTriggerMode 1.3.6.1.4.1.25049.17.11.1.8
The Trigger Mode of the Digital I/O
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER invalid(1), risingEdge(2), fallingEdge(3), risingFallingEdge(4)  

ogEmdDioCounter 1.3.6.1.4.1.25049.17.11.1.9
The trigger counter of this Digital I/O
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogNetInterfaceTable 1.3.6.1.4.1.25049.17.12
This devices network interface status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NetInterfaceEntry

ogNetInterfaceEntry 1.3.6.1.4.1.25049.17.12.1
EMD status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  NetInterfaceEntry  

ogNetInterfaceIndex 1.3.6.1.4.1.25049.17.12.1.1
Index within the network interface status table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogNetInterfaceName 1.3.6.1.4.1.25049.17.12.1.2
The name of a network interface.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogNetInterfaceType 1.3.6.1.4.1.25049.17.12.1.3
The type of this network interface entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unavailable(1), ethernet(2), wifi(3), cellModem(4), v92Modem(5), vpn(6)  

ogNetInterfaceState 1.3.6.1.4.1.25049.17.12.1.4
The current status of this network interface entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unavailable(1), down(2), starting(3), up(4), stopping(5)  

ogPowerSupplyTable 1.3.6.1.4.1.25049.17.13
This entity's Power Supply table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PowerSupplyEntry

ogPowerSupplyEntry 1.3.6.1.4.1.25049.17.13.1
Power Supply status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  PowerSupplyEntry  

ogPowerSupplyIndex 1.3.6.1.4.1.25049.17.13.1.1
Index within the Power Supply status table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..65535  

ogPowerSupplyName 1.3.6.1.4.1.25049.17.13.1.2
The name of the Power Supply.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogPowerSupplyInputVoltage 1.3.6.1.4.1.25049.17.13.1.3
Current temperature of the Power Supply
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogPowerSupplyOutputCurrent 1.3.6.1.4.1.25049.17.13.1.4
Current temperature of the Power Supply
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogPowerSupplyTemperature 1.3.6.1.4.1.25049.17.13.1.5
Current temperature of the Power Supply
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsTable 1.3.6.1.4.1.25049.17.14
Ths Uninterruptable Power Supply (UPS) status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsEntry

ogUpsEntry 1.3.6.1.4.1.25049.17.14.1
Digital I/O status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  UpsEntry  

ogUpsIndex 1.3.6.1.4.1.25049.17.14.1.1
Index within the UPS status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogUpsName 1.3.6.1.4.1.25049.17.14.1.2
The ID of this UPS.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogUpsDescription 1.3.6.1.4.1.25049.17.14.1.3
A description of this UPS.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogUpsType 1.3.6.1.4.1.25049.17.14.1.4
The UPS driver type.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogUpsLogEnabled 1.3.6.1.4.1.25049.17.14.1.5
The logging status of the UPS
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogUpsConnectType 1.3.6.1.4.1.25049.17.14.1.6
How the UPS device is being monitored.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), usb(2), http(3), https(4), snmp(5), serial(6)  

ogUpsState 1.3.6.1.4.1.25049.17.14.1.7
The current state the UPS is running in.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), onLine(2), onBattery(3), lowBattery(4), onBypass(5)  

ogUpsTemperature 1.3.6.1.4.1.25049.17.14.1.8
The UPS temperature. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsHumidity 1.3.6.1.4.1.25049.17.14.1.9
The UPS humidity. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsBatteryState 1.3.6.1.4.1.25049.17.14.1.10
The current state of the UPS battery.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), normal(2), warning(3), low(4), depleted(5)  

ogUpsBatteryRunTime 1.3.6.1.4.1.25049.17.14.1.11
Battery runtime (seconds). Negative if unavailable
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..31449600  

ogUpsBatteryRunTimeLow 1.3.6.1.4.1.25049.17.14.1.12
Estimated remaining battery runtime when UPS switches to Low Battery. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..31449600  

ogUpsBatteryRunTimeRestart 1.3.6.1.4.1.25049.17.14.1.13
Minimum battery runtime for UPS restart after power-off (seconds). Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..31449600  

ogUpsBatteryCharge 1.3.6.1.4.1.25049.17.14.1.14
Estimated percent of Battery charge remaining. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

ogUpsBatteryVoltage 1.3.6.1.4.1.25049.17.14.1.15
The magnitude of the current battery voltage. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsBatteryNominalVoltage 1.3.6.1.4.1.25049.17.14.1.16
Nominal battery voltage (V). Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsBatteryCurrent 1.3.6.1.4.1.25049.17.14.1.17
The UPS battery current. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsBatteryNominalCurrent 1.3.6.1.4.1.25049.17.14.1.18
The nominal UPS battery current. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsBatteryTemperature 1.3.6.1.4.1.25049.17.14.1.19
The UPS battery temperature. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsInputFrequency 1.3.6.1.4.1.25049.17.14.1.20
Input line frequency (Hz). Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsInputNominalFrequency 1.3.6.1.4.1.25049.17.14.1.21
Nominal input line frequency (Hz). Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsInputVoltage 1.3.6.1.4.1.25049.17.14.1.22
The magnitude of the UPS input voltage. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsInputNominalVoltage 1.3.6.1.4.1.25049.17.14.1.23
The nominal input voltage. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsInputCurrent 1.3.6.1.4.1.25049.17.14.1.24
The input current. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsInputNominalCurrent 1.3.6.1.4.1.25049.17.14.1.25
The nominal input current. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsOutputFrequency 1.3.6.1.4.1.25049.17.14.1.26
Output line frequency (Hz). Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsOutputNominalFrequency 1.3.6.1.4.1.25049.17.14.1.27
Nominal output line frequency (Hz). Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsOutputVoltage 1.3.6.1.4.1.25049.17.14.1.28
The magnitude of the UPS output voltage. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsOutputNominalVoltage 1.3.6.1.4.1.25049.17.14.1.29
The nominal magnitude of the UPS output voltage. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsOutputCurrent 1.3.6.1.4.1.25049.17.14.1.30
The magnitude of the UPS input current. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsOutputNominalCurrent 1.3.6.1.4.1.25049.17.14.1.31
The nominal magnitude of the UPS input current. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsOutputLoad 1.3.6.1.4.1.25049.17.14.1.32
Estimated percent of UPS power capacity being used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..100  

ogUpsOutputPower 1.3.6.1.4.1.25049.17.14.1.33
The current value of apparent power (Volt-Amps). Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsOutputTruePower 1.3.6.1.4.1.25049.17.14.1.34
The current value of real power (Watts). Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogUpsCounter 1.3.6.1.4.1.25049.17.14.1.35
Number of alerts triggered on the UPS
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogRpcTable 1.3.6.1.4.1.25049.17.15
This entity's Remote Power Controller (RPC) table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RpcEntry

ogRpcEntry 1.3.6.1.4.1.25049.17.15.1
RPC status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  RpcEntry  

ogRpcIndex 1.3.6.1.4.1.25049.17.15.1.1
Index within the RPC status table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..65535  

ogRpcName 1.3.6.1.4.1.25049.17.15.1.2
The name of the RPC device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogRpcDescription 1.3.6.1.4.1.25049.17.15.1.3
A description for the RPC device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogRpcType 1.3.6.1.4.1.25049.17.15.1.4
A type for the RPC device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogRpcLogEnabled 1.3.6.1.4.1.25049.17.15.1.5
The logging status of the RPC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogRpcOutletTotal 1.3.6.1.4.1.25049.17.15.1.6
The number of outlets on this RPC
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogRpcMaxTemperature 1.3.6.1.4.1.25049.17.15.1.7
Maximum temperature on the RPC
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogRpcConnectType 1.3.6.1.4.1.25049.17.15.1.8
How the RPC device is connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER serial(1), network(2)  

ogRpcInputFrequency 1.3.6.1.4.1.25049.17.15.1.9
Input line frequency (Hz). Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogRpcInputVoltage 1.3.6.1.4.1.25049.17.15.1.10
The magnitude of the RPC input voltage. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogRpcInputCurrent 1.3.6.1.4.1.25049.17.15.1.11
The input current. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogRpcCounter 1.3.6.1.4.1.25049.17.15.1.12
Number of alerts triggered on the RPC
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogRpcOutletTable 1.3.6.1.4.1.25049.17.16
This RPC's outlet table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RpcOutletEntry

ogRpcOutletEntry 1.3.6.1.4.1.25049.17.16.1
RPC Outlet status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  RpcOutletEntry  

ogRpcOutletIndex 1.3.6.1.4.1.25049.17.16.1.1
Index within the RPC outlet table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogRpcOutletRpc 1.3.6.1.4.1.25049.17.16.1.2
The RPC this outlet belongs to
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ogRpcOutletName 1.3.6.1.4.1.25049.17.16.1.3
The name of the RPC outlet.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogRpcOutletState 1.3.6.1.4.1.25049.17.16.1.4
The power status of the RPC outlet
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), transitioning(3), unavailable(4)  

ogRpcOutletFrequency 1.3.6.1.4.1.25049.17.16.1.5
Output line frequency (Hz). Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogRpcOutletVoltage 1.3.6.1.4.1.25049.17.16.1.6
The voltage on this outlet. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2640  

ogRpcOutletCurrent 1.3.6.1.4.1.25049.17.16.1.7
Current measured on this outlet. Negative if unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..25500  

ogRpcOutletLoad 1.3.6.1.4.1.25049.17.16.1.8
Estimated percent of RPC outlet power capacity being used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

ogCellModemTable 1.3.6.1.4.1.25049.17.17
Ths cellular modem status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CellModemEntry

ogCellModemEntry 1.3.6.1.4.1.25049.17.17.1
A cellular modem status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  CellModemEntry  

ogCellModemIndex 1.3.6.1.4.1.25049.17.17.1.1
Index of the cellular modem status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogCellModemVendor 1.3.6.1.4.1.25049.17.17.1.2
The Manufacturer ID of Cellular Modem.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogCellModemModel 1.3.6.1.4.1.25049.17.17.1.3
The Cellular Modem model name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogCellModemEnabled 1.3.6.1.4.1.25049.17.17.1.4
The enabled state of the modem.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ogCellModemConnected 1.3.6.1.4.1.25049.17.17.1.5
The connected state of the modem.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2)  

ogCellModemNetwork 1.3.6.1.4.1.25049.17.17.1.6
The name of the network provider.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogCellModemRegistered 1.3.6.1.4.1.25049.17.17.1.7
The registration state of the modem.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER registered(1), unregistered(2)  

ogCellModemTower 1.3.6.1.4.1.25049.17.17.1.8
The current cellular tower ID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogCellModemRadioTechnology 1.3.6.1.4.1.25049.17.17.1.9
The current Radio Access Technology being used
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unavailable(1), cdma(2), evdo(3), gsm(4), umts(5), lte(6)  

ogCellModemApn 1.3.6.1.4.1.25049.17.17.1.10
The APN configured for this cellmodem.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogCellModem3gRssi 1.3.6.1.4.1.25049.17.17.1.11
The current 3G Received Signal Strength (RSSI) if applicable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -99..99  

ogCellModem4gRssi 1.3.6.1.4.1.25049.17.17.1.12
The current 4G Received Signal Strength (RSSI) if applicable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -99..99  

ogCellModemSessionTime 1.3.6.1.4.1.25049.17.17.1.13
The number of seconds the modem session has been up for.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogCellModemSelectedSimCard 1.3.6.1.4.1.25049.17.17.1.14
The SIM card currently being used by this modem.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogCellModemTemperature 1.3.6.1.4.1.25049.17.17.1.15
The current temperature of the Cellular Modem.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogCellModemCounter 1.3.6.1.4.1.25049.17.17.1.16
The number of alerts the modem has triggered.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiClientTable 1.3.6.1.4.1.25049.17.18
Ths wireless client status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WifiClientEntry

ogWifiClientEntry 1.3.6.1.4.1.25049.17.18.1
A wireless client status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  WifiClientEntry  

ogWifiClientIndex 1.3.6.1.4.1.25049.17.18.1.1
Index of the wireless client status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogWifiClientInterface 1.3.6.1.4.1.25049.17.18.1.2
The wireless client network interface name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

ogWifiClientEnabled 1.3.6.1.4.1.25049.17.18.1.3
The wireless client enabled state
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogWifiClientEssid 1.3.6.1.4.1.25049.17.18.1.4
The ESSID this wireless client is currently associated with.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogWifiClientIeeeMode 1.3.6.1.4.1.25049.17.18.1.5
The IEEE 802.11 mode of this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unavailable(1), ieee802Dot11B(2), ieee802Dot11BG(3), ieee802Dot11BGN(4), ieee802Dot11ABGN(5)  

ogWifiClientMode 1.3.6.1.4.1.25049.17.18.1.6
The operating mode of this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unavailable(1), managed(2), adhoc(3)  

ogWifiClientFrequency 1.3.6.1.4.1.25049.17.18.1.7
The current frequency of this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ogWifiClientApMac 1.3.6.1.4.1.25049.17.18.1.8
The Access Point ID this wireless client is associated with.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

ogWifiClientBitRate 1.3.6.1.4.1.25049.17.18.1.9
The current bit-rate of this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ogWifiClientTxPower 1.3.6.1.4.1.25049.17.18.1.10
The current Tx-Power of this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogWifiClientLinkQuality 1.3.6.1.4.1.25049.17.18.1.11
The normalized link quality of this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ogWifiClientRssi 1.3.6.1.4.1.25049.17.18.1.12
The current Signal Level of this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogWifiClientRxInvalidNwid 1.3.6.1.4.1.25049.17.18.1.13
The count of invalid Network ID's for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiClientRxInvalidCrypt 1.3.6.1.4.1.25049.17.18.1.14
The count of invalid crypt's for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiClientRxInvalidFrag 1.3.6.1.4.1.25049.17.18.1.15
The count of invalid frag's for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiClientRxInvalidRetries 1.3.6.1.4.1.25049.17.18.1.16
The count of invalid retries for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiClientRxInvalidMisc 1.3.6.1.4.1.25049.17.18.1.17
The count of invalid misc's for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiClientMissedBeacon 1.3.6.1.4.1.25049.17.18.1.18
The count of missed beacon's for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiClientCounter 1.3.6.1.4.1.25049.17.18.1.19
The number of alerts triggered by this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiApTable 1.3.6.1.4.1.25049.17.19
Ths wireless interface status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WifiApEntry

ogWifiApEntry 1.3.6.1.4.1.25049.17.19.1
A wireless interface status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  WifiApEntry  

ogWifiApIndex 1.3.6.1.4.1.25049.17.19.1.1
Index of the wireless server status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogWifiApInterface 1.3.6.1.4.1.25049.17.19.1.2
The wireless access point network interface name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

ogWifiApEnabled 1.3.6.1.4.1.25049.17.19.1.3
The enabled status of the wireless server.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ogWifiApSsid 1.3.6.1.4.1.25049.17.19.1.4
The SSID for this wireless access point.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogWifiApIeeeMode 1.3.6.1.4.1.25049.17.19.1.5
The IEEE 802.11 mode of this wireless access point.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unavailable(1), ieee802Dot11B(2), ieee802Dot11BG(3), ieee802Dot11BGN(4), ieee802Dot11ABGN(5)  

ogWifiApFrequency 1.3.6.1.4.1.25049.17.19.1.6
The current frequency of this wireless access point.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ogWifiApTxPower 1.3.6.1.4.1.25049.17.19.1.7
The current Tx-Power of this wireless access point.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogWifiApCounter 1.3.6.1.4.1.25049.17.19.1.8
The number of alerts triggered by this wireless access point.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiApClientTable 1.3.6.1.4.1.25049.17.20
This RPC's outlet table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WifiApClientEntry

ogWifiApClientEntry 1.3.6.1.4.1.25049.17.20.1
RPC Outlet status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  WifiApClientEntry  

ogWifiApClientIndex 1.3.6.1.4.1.25049.17.20.1.1
Index within the wireless AP client table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogWifiApClientAp 1.3.6.1.4.1.25049.17.20.1.2
The wireless AP this client is assiciated with.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ogWifiApClientMac 1.3.6.1.4.1.25049.17.20.1.3
The MAC address of the Access Point this wireless client is associated with.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

ogWifiApClientInactiveTime 1.3.6.1.4.1.25049.17.20.1.4
The Inactive Time for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiApClientRxBytes 1.3.6.1.4.1.25049.17.20.1.5
The number of received bytes for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiApClientRxPackets 1.3.6.1.4.1.25049.17.20.1.6
The number of received packets for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiApClientTxBytes 1.3.6.1.4.1.25049.17.20.1.7
The number of transmitted bytes for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiApClientTxPackets 1.3.6.1.4.1.25049.17.20.1.8
The number of transmitted packets for this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogWifiApClientRssi 1.3.6.1.4.1.25049.17.20.1.9
The current Signal Level of this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogWifiApClientTxBitRate 1.3.6.1.4.1.25049.17.20.1.10
The current transmission bit-rate of this wireless client.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ogCheckTable 1.3.6.1.4.1.25049.17.21
Ths auto-response check table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CheckEntry

ogCheckEntry 1.3.6.1.4.1.25049.17.21.1
An auto-response check entry
Status: current Access: not-accessible
OBJECT-TYPE    
  CheckEntry  

ogCheckIndex 1.3.6.1.4.1.25049.17.21.1.1
Index of the auto-response rule
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogCheckName 1.3.6.1.4.1.25049.17.21.1.2
The ID of this auto-response rule.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogCheckRepeatTimeout 1.3.6.1.4.1.25049.17.21.1.3
The minimum seconds before trigger actions can be repeated for this auto-response.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

ogCheckResetTimeout 1.3.6.1.4.1.25049.17.21.1.4
The minimum seconds after resolution before this auto-response can be triggered again.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

ogCheckType 1.3.6.1.4.1.25049.17.21.1.5
The auto-response check type
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), serialSignal(2), serialUser(3), serialPattern(4), hostPing(5), hostService(6), hostUser(7), webUser(8), envTemperature(9), envHumidity(10), dioInput(11), netInterface(12), powerSupplyInputVoltage(13), powerSupplyOutputCurrent(14), powerSupplyTemperature(15), upsInputVoltage(16), upsBatteryCharge(17), upsBatteryTemperature(18), upsOutputLoad(19), upsInputFrequency(20), upsStateOnBattery(21), upsStateLowBattery(22), rpcInput(23), rpcOutletState(24), rpcOutletOutput(25), cellMessage(26), cellData(27), cellSignal(28), cellApn(29), cellTower(30), cellNetwork(31), wirelessClientConnect(32), wirelessClientSignal(33), wirelessApAssociation(34), wirelessApAuthentication(35), dialPoolHealth(36), custom(255)  

ogCheckTriggerActions 1.3.6.1.4.1.25049.17.21.1.6
The number of Trigger Actions configured for the auto-response.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogCheckResolveActions 1.3.6.1.4.1.25049.17.21.1.7
The number of Resolve Actions configured for the auto-response.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ogCheckDeviceTable 1.3.6.1.4.1.25049.17.22
The auto-response device reference table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CheckDeviceEntry

ogCheckDeviceEntry 1.3.6.1.4.1.25049.17.22.1
RPC Outlet status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  CheckDeviceEntry  

ogCheckDeviceIndex 1.3.6.1.4.1.25049.17.22.1.1
Index within the auto-response device outlet table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogCheckDeviceCheck 1.3.6.1.4.1.25049.17.22.1.2
The check this device is associated with.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ogCheckDeviceName 1.3.6.1.4.1.25049.17.22.1.3
The name of a device pertaining to the auto-reponse.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogCheckDeviceRef 1.3.6.1.4.1.25049.17.22.1.4
The reference ID of the device pertaining to the auto-reponse.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ogAlarm 1.3.6.1.4.1.25049.17.23
OBJECT IDENTIFIER    

ogAlarmLogTable 1.3.6.1.4.1.25049.17.23.1
The alarm history table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmLogEntry

ogAlarmLogEntry 1.3.6.1.4.1.25049.17.23.1.1
An alarm entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  AlarmLogEntry  

ogAlarmLogIndex 1.3.6.1.4.1.25049.17.23.1.1.1
Index within the current alarm table of this alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogAlarmEventId 1.3.6.1.4.1.25049.17.23.1.1.2
Unique event ID for this alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogAlarmName 1.3.6.1.4.1.25049.17.23.1.1.3
The check ID that this alarm pertains to.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

ogAlarmCheck 1.3.6.1.4.1.25049.17.23.1.1.4
The auto-response index this alarm relates to.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogAlarmInstance 1.3.6.1.4.1.25049.17.23.1.1.5
The reference index for this alarm instance.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogAlarmTime 1.3.6.1.4.1.25049.17.23.1.1.6
The UTC date and time for when this alarm was created.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

ogAlarmType 1.3.6.1.4.1.25049.17.23.1.1.7
A reference to an Alarm Type Object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER serialSignalCts(1), serialSignalDcd(2), serialSignalDsr(3), serialPatternTx(4), serialPatternRx(5), serialUserSession(6), hostPingDown(7), hostPingUp(8), hostServiceDown(9), hostServiceUp(10), hostUserSession(11), webUserSession(12), envTemperatureLow(13), envTemperatureHigh(14), envHumidityLow(15), envHumidityHigh(16), dioSignalOpened(17), dioSignalClosed(18), netInterfaceDown(19), netInterfaceStarting(20), netInterfaceUp(21), netInterfaceStopping(22), powerSupplyInputVoltageLow(23), powerSupplyInputVoltageHigh(24), powerSupplyOutputCurrentLow(25), powerSupplyOutputCurrentHigh(26), powerSupplyTemperatureLow(27), powerSupplyTemperatureHigh(28), upsTemperatureHigh(29), upsTemperatureLow(30), upsHumidityHigh(31), upsHumidityLow(32), upsOnBattery(33), upsLowBattery(34), upsBatteryChargeLow(35), upsBatteryChargeHigh(36), upsBatteryVoltageLow(37), upsBatteryVoltageHigh(38), upsBatteryCurrentLow(39), upsBatteryCurrentHigh(40), upsBatteryTemperatureLow(41), upsBatteryTemperatureHigh(42), upsInputFrequencyLow(43), upsInputFrequencyHigh(44), upsInputVoltageLow(45), upsInputVoltageHigh(46), upsInputCurrentLow(47), upsInputCurrentHigh(48), upsOutputFrequencyLow(49), upsOutputFrequencyHigh(50), upsOutputVoltageLow(51), upsOutputVoltageHigh(52), upsOutputCurrentLow(53), upsOutputCurrentHigh(54), upsOutputLoadLow(55), upsOutputLoadHigh(56), upsOutputPowerLow(57), upsOutputPowerHigh(58), upsOutputTruePowerLow(59), upsOutputTruePowerHigh(60), rpcInputFrequencyLow(61), rpcInputFrequencyHigh(62), rpcInputVoltageLow(63), rpcInputVoltageHigh(64), rpcInputCurrentLow(65), rpcInputCurrentHigh(66), rpcOutletFrequencyHigh(67), rpcOutletFrequencyLow(68), rpcOutletVoltageHigh(69), rpcOutletVoltageLow(70), rpcOutletCurrentHigh(71), rpcOutletCurrentLow(72), rpcOutletStateOff(73), rpcOutletStateOn(74), cellDataUsage(75), cellMessageReceived(76), cellSignalLow(77), cellSignalHigh(78), cellApnChanged(79), cellTowerChanged(80), cellNetworkChanged(81), wirelessClientConnected(82), wirelessClientDisconnected(83), wirelessClientSignalLow(84), wirelessClientSignalHigh(85), wirelessApAssociation(86), wirelessApDisassociation(87), wirelessApAuthenticationFailure(88), dialPoolHealth(89), customCheckFailure(255), unknown(65535)  

ogAlarmSummary 1.3.6.1.4.1.25049.17.23.1.1.8
The human readable summary of this alarm.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ogAlarmDevice 1.3.6.1.4.1.25049.17.23.1.1.9
The device ID that this alarm pertains to.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ogAlarmUser 1.3.6.1.4.1.25049.17.23.1.1.10
The user ID that this alarm pertains to.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ogAlarmTriggerValue 1.3.6.1.4.1.25049.17.23.1.1.11
The threshold value which triggers the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogAlarmCurrentValue 1.3.6.1.4.1.25049.17.23.1.1.12
The value as of the time of this entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogAlarmPreviousValue 1.3.6.1.4.1.25049.17.23.1.1.13
The former value of this entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogAlarmState 1.3.6.1.4.1.25049.17.23.1.1.14
The effective alarm state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), triggered(2), resolving(3), waiting(4), disabled(5), unresolvable(6)  

ogCurrentAlarmTable 1.3.6.1.4.1.25049.17.23.2
The alarm history table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CurrentAlarmEntry

ogCurrentAlarmEntry 1.3.6.1.4.1.25049.17.23.2.1
An alarm entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  CurrentAlarmEntry  

ogCurrentAlarmIndex 1.3.6.1.4.1.25049.17.23.2.1.1
Index within the current alarm table of this alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

ogCurrentAlarmEventId 1.3.6.1.4.1.25049.17.23.2.1.2
Unique event ID for this alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogCurrentAlarmName 1.3.6.1.4.1.25049.17.23.2.1.3
The ID of the check this alarm pertains to.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

ogCurrentAlarmCheck 1.3.6.1.4.1.25049.17.23.2.1.4
The auto-response index this alarm relates to.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogCurrentAlarmInstance 1.3.6.1.4.1.25049.17.23.2.1.5
The reference index for this alarm instance.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogCurrentAlarmTime 1.3.6.1.4.1.25049.17.23.2.1.6
The UTC date and time for when this alarm was created.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

ogCurrentAlarmType 1.3.6.1.4.1.25049.17.23.2.1.7
The specific Alarm Type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER serialSignalCts(1), serialSignalDcd(2), serialSignalDsr(3), serialPatternTx(4), serialPatternRx(5), serialUserSession(6), hostPingDown(7), hostPingUp(8), hostServiceDown(9), hostServiceUp(10), hostUserSession(11), webUserSession(12), envTemperatureLow(13), envTemperatureHigh(14), envHumidityLow(15), envHumidityHigh(16), dioSignalOpened(17), dioSignalClosed(18), netInterfaceDown(19), netInterfaceStarting(20), netInterfaceUp(21), netInterfaceStopping(22), powerSupplyInputVoltageLow(23), powerSupplyInputVoltageHigh(24), powerSupplyOutputCurrentLow(25), powerSupplyOutputCurrentHigh(26), powerSupplyTemperatureLow(27), powerSupplyTemperatureHigh(28), upsTemperatureHigh(29), upsTemperatureLow(30), upsHumidityHigh(31), upsHumidityLow(32), upsOnBattery(33), upsLowBattery(34), upsBatteryChargeLow(35), upsBatteryChargeHigh(36), upsBatteryVoltageLow(37), upsBatteryVoltageHigh(38), upsBatteryCurrentLow(39), upsBatteryCurrentHigh(40), upsBatteryTemperatureLow(41), upsBatteryTemperatureHigh(42), upsInputFrequencyLow(43), upsInputFrequencyHigh(44), upsInputVoltageLow(45), upsInputVoltageHigh(46), upsInputCurrentLow(47), upsInputCurrentHigh(48), upsOutputFrequencyLow(49), upsOutputFrequencyHigh(50), upsOutputVoltageLow(51), upsOutputVoltageHigh(52), upsOutputCurrentLow(53), upsOutputCurrentHigh(54), upsOutputLoadLow(55), upsOutputLoadHigh(56), upsOutputPowerLow(57), upsOutputPowerHigh(58), upsOutputTruePowerLow(59), upsOutputTruePowerHigh(60), rpcInputFrequencyLow(61), rpcInputFrequencyHigh(62), rpcInputVoltageLow(63), rpcInputVoltageHigh(64), rpcInputCurrentLow(65), rpcInputCurrentHigh(66), rpcOutletFrequencyHigh(67), rpcOutletFrequencyLow(68), rpcOutletVoltageHigh(69), rpcOutletVoltageLow(70), rpcOutletCurrentHigh(71), rpcOutletCurrentLow(72), rpcOutletStateOff(73), rpcOutletStateOn(74), cellDataUsage(75), cellMessageReceived(76), cellSignalLow(77), cellSignalHigh(78), cellApnChanged(79), cellTowerChanged(80), cellNetworkChanged(81), wirelessClientConnected(82), wirelessClientDisconnected(83), wirelessClientSignalLow(84), wirelessClientSignalHigh(85), wirelessApAssociation(86), wirelessApDisassociation(87), wirelessApAuthenticationFailure(88), dialPoolHealth(89), customCheckFailure(255), unknown(65535)  

ogCurrentAlarmSummary 1.3.6.1.4.1.25049.17.23.2.1.8
A readable summary of this alarm.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ogCurrentAlarmDevice 1.3.6.1.4.1.25049.17.23.2.1.9
The ID of the device this alarm pertains to.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ogCurrentAlarmUser 1.3.6.1.4.1.25049.17.23.2.1.10
The ID of the user this alarm pertains to.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ogCurrentAlarmTriggerValue 1.3.6.1.4.1.25049.17.23.2.1.11
The threshold value which triggers the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogCurrentAlarmCurrentValue 1.3.6.1.4.1.25049.17.23.2.1.12
The value as of the time of this entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogCurrentAlarmPreviousValue 1.3.6.1.4.1.25049.17.23.2.1.13
The former value of this entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ogCurrentAlarmState 1.3.6.1.4.1.25049.17.23.2.1.14
The effective alarm state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), triggered(2), resolving(3), waiting(4), disabled(5), unresolvable(6)  

ogStatus2NotificationPrefix 1.3.6.1.4.1.25049.17.100
OBJECT IDENTIFIER    

ogMibNotifications 1.3.6.1.4.1.25049.17.100.0
OBJECT IDENTIFIER    

ogSerialSignalNotification 1.3.6.1.4.1.25049.17.100.0.1
The notification sent when a serial signal changes.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogSerialPatternNotification 1.3.6.1.4.1.25049.17.100.0.2
The notification sent when a pattern is matched on a serial port .
Status: current Access: read-only
NOTIFICATION-TYPE    

ogSerialUserNotification 1.3.6.1.4.1.25049.17.100.0.3
The notification sent when a user logs in or out of a serial console.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogHostPingNotification 1.3.6.1.4.1.25049.17.100.0.4
The notification sent when a host stops or resumes responding to a ping.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogHostServiceNotification 1.3.6.1.4.1.25049.17.100.0.5
The notification sent when a host service stops or resumes.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogHostUserNotification 1.3.6.1.4.1.25049.17.100.0.6
The notification sent when a user logs in or out of a network host.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogWebUserNotification 1.3.6.1.4.1.25049.17.100.0.7
The notification sent when a user logs in or out of the web interface.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogEmdTemperatureNotification 1.3.6.1.4.1.25049.17.100.0.8
The notification sent when a temperature event occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogEmdHumidityNotification 1.3.6.1.4.1.25049.17.100.0.9
The notification sent when a humidity event occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogEmdDioNotification 1.3.6.1.4.1.25049.17.100.0.10
The notification sent when a Digital I/O input event occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogPowerSupplyInputNotification 1.3.6.1.4.1.25049.17.100.0.11
The notification sent when a power supply voltage alarm occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogPowerSupplyOutputNotification 1.3.6.1.4.1.25049.17.100.0.12
The notification sent when a power supply voltage alarm occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogPowerSupplyTempNotification 1.3.6.1.4.1.25049.17.100.0.13
The notification sent when a power supply voltage alarm occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogUpsNotification 1.3.6.1.4.1.25049.17.100.0.14
The notification sent when a UPS alarm occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogUpsBatteryNotification 1.3.6.1.4.1.25049.17.100.0.15
The notification sent when a UPS battery alarm occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogUpsInputNotification 1.3.6.1.4.1.25049.17.100.0.16
The notification sent when a UPS input alarm occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogUpsOutputNotification 1.3.6.1.4.1.25049.17.100.0.17
The notification sent when a UPS output alarm occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogRpcInputNotification 1.3.6.1.4.1.25049.17.100.0.18
The notification sent when a RPC input alarm occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogRpcOutputNotification 1.3.6.1.4.1.25049.17.100.0.19
The notification sent when a RPC output alarm occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogRpcOutletNotification 1.3.6.1.4.1.25049.17.100.0.20
The notification sent when a RPC output alarm occurs
Status: current Access: read-only
NOTIFICATION-TYPE    

ogNetInterfaceNotification 1.3.6.1.4.1.25049.17.100.0.21
The notification sent when a network interface event occurs.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogCellDataNotification 1.3.6.1.4.1.25049.17.100.0.22
The notification sent when a cellular data alarm occurs.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogCellMessageNotification 1.3.6.1.4.1.25049.17.100.0.23
The notification sent when an SMS command alarm occurs.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogCellSignalNotification 1.3.6.1.4.1.25049.17.100.0.24
The notification sent when a cellular signal alarm occurs.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogCellApnNotification 1.3.6.1.4.1.25049.17.100.0.25
The notification sent when a cellular APN alarm occurs.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogCellTowerNotification 1.3.6.1.4.1.25049.17.100.0.26
The notification sent when a cellular tower alarm occurs.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogCellNetworkNotification 1.3.6.1.4.1.25049.17.100.0.27
The notification sent when a cellular network alarm occurs.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogWifiClientConnectNotification 1.3.6.1.4.1.25049.17.100.0.28
The notification sent when a wireless client connects or disconnects.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogWifiClientSignalNotification 1.3.6.1.4.1.25049.17.100.0.29
The notification sent when a wireless client signal changes.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogWifiApAssociationNotification 1.3.6.1.4.1.25049.17.100.0.30
The notification sent when a wireless client connects or disconnects to this AP.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogWifiApAuthNotification 1.3.6.1.4.1.25049.17.100.0.31
The notification sent when a wireless client fails to authenticate with this AP.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogDialPoolHealthNotification 1.3.6.1.4.1.25049.17.100.0.32
The notification sent when dial-pool health alarm occurs.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogCustomNotification 1.3.6.1.4.1.25049.17.100.0.33
The notification sent when a custom check is triggered.
Status: current Access: read-only
NOTIFICATION-TYPE    

ogStatus2Conformance 1.3.6.1.4.1.25049.17.65535
OBJECT IDENTIFIER    

ogStatus2Compliances 1.3.6.1.4.1.25049.17.65535.1
OBJECT IDENTIFIER    

ogStatus2Groups 1.3.6.1.4.1.25049.17.65535.2
OBJECT IDENTIFIER    

ogStatus2Compliance 1.3.6.1.4.1.25049.17.65535.1.1
The compliance statement for the Opengear status MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

ogBasicStatusGroup 1.3.6.1.4.1.25049.17.65535.2.1
A collection of objects to retrieve Opengear statistics.
Status: current Access: read-only
OBJECT-GROUP    

ogBasicAlarmGroup 1.3.6.1.4.1.25049.17.65535.2.2
A collection of objects to report Opengear alarms.
Status: current Access: read-only
OBJECT-GROUP    

ogBasicNotificationGroup 1.3.6.1.4.1.25049.17.65535.2.3
A collection of notifications for the status system.
Status: current Access: read-only
NOTIFICATION-GROUP