NNCEXTE3-MIB
File:
NNCEXTE3-MIB.mib (27643 bytes)
Imported modules
Imported symbols
Defined Types
NncExtE3Current15MinEntry |
|
SEQUENCE |
|
|
|
|
nncExtE3Current15MinESs |
Gauge32 |
|
|
nncExtE3Current15MinSESs |
Gauge32 |
|
|
nncExtE3Current15MinSEFs |
Gauge32 |
|
NncExtE3Interval15MinEntry |
|
SEQUENCE |
|
|
|
|
nncExtE3Interval15MinNumber |
Integer32 |
|
|
nncExtE3Interval15MinESs |
Gauge32 |
|
|
nncExtE3Interval15MinSESs |
Gauge32 |
|
|
nncExtE3Interval15MinSEFs |
Gauge32 |
|
NncExtE3Total24HrEntry |
|
SEQUENCE |
|
|
|
|
nncExtE3Total24HrESs |
Gauge32 |
|
|
nncExtE3Total24HrSESs |
Gauge32 |
|
|
nncExtE3Total24HrSEFs |
Gauge32 |
|
NncExtE3FarEndCurrent15MinEntry |
|
SEQUENCE |
|
|
|
|
nncExtE3FarEndCurrent15MinFEBEs |
Gauge32 |
|
|
nncExtE3FarEndCurrent15MinESs |
Gauge32 |
|
|
nncExtE3FarEndCurrent15MinSESs |
Gauge32 |
|
NncExtE3FarEndInterval15MinEntry |
|
SEQUENCE |
|
|
|
|
nncExtE3FarEndInterval15MinNumber |
Integer32 |
|
|
nncExtE3FarEndInterval15MinFEBEs |
Gauge32 |
|
|
nncExtE3FarEndInterval15MinESs |
Gauge32 |
|
|
nncExtE3FarEndInterval15MinSESs |
Gauge32 |
|
NncExtE3FarEndTotal24HrEntry |
|
SEQUENCE |
|
|
|
|
nncExtE3FarEndTotal24HrFEBEs |
Gauge32 |
|
|
nncExtE3FarEndTotal24HrESs |
Gauge32 |
|
|
nncExtE3FarEndTotal24HrSESs |
Gauge32 |
|
Defined Values
nncExtE3 |
1.3.6.1.4.1.123.3.40 |
This module contains definitions for Newbridge extensions
to E3 objects. It is used as a supplement to rfc1407. |
MODULE-IDENTITY |
|
|
|
nncExtE3Current15MinEntry |
1.3.6.1.4.1.123.3.40.1.1.1 |
An entry in nncExtE3Current15MinTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
NncExtE3Current15MinEntry |
|
|
nncExtE3Current15MinESs |
1.3.6.1.4.1.123.3.40.1.1.1.1 |
The counter associated with the number of Path Errored
Seconds encountered by a E3 interface in the current
15 minute interval.
This counts the seconds containing one or more BIP
errors, one or more LOF defects, one or more LOS defects,
or a detected incoming AIS. This counter is valid when
an interface is configured for Direct cell mapping.
When an interface is configured for PLCP cell mapping,
the counter returns the last valid count when the port
is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3Current15MinSESs |
1.3.6.1.4.1.123.3.40.1.1.1.2 |
The counter associated with the number of Path Severely
Errored Seconds encountered by a E3 interface in the
current 15 minute interval.
This counts the seconds containing 34 or more BIP
errors, one or more LOF defects, one or more LOS defects,
or a detected incoming AIS. This counter is valid when
an interface is configured for Direct cell mapping.
When an interface is configured for PLCP cell mapping,
the counter returns the last valid count when the
port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3Current15MinSEFs |
1.3.6.1.4.1.123.3.40.1.1.1.3 |
The counter associated with the number of Path Severely
Errored Frames encountered by a E3 interface in the
current 15 minute interval.
This counts framing pattern errors. In Direct cell
mapping mode, this is the count of frames with errored
FA1/FA2 bytes in the G.832 overhead. In PLCP mode,
this is the count of frames with an errored G.751
Frame Alignment byte. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3Interval15MinEntry |
1.3.6.1.4.1.123.3.40.1.2.1 |
An entry in nncExtE3Interval15MinTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
NncExtE3Interval15MinEntry |
|
|
nncExtE3Interval15MinNumber |
1.3.6.1.4.1.123.3.40.1.2.1.1 |
A number between 1 and 96, where 1 is the most recently
completed 15 minute interval and 96 is the least recently
completed 15 minutes interval (assuming that all 96
intervals are valid). |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..96 |
|
nncExtE3Interval15MinESs |
1.3.6.1.4.1.123.3.40.1.2.1.2 |
The counter associated with the number of Path Errored
Seconds encountered by a E3 interface in one of the
previous 15 minute intervals.
This counts the seconds containing one or more BIP
errors, one or more LOF defects, one or more LOS defects,
or a detected incoming AIS. This counter is valid when
an interface is configured for Direct cell mapping.
When an interface is configured for PLCP cell mapping,
the counter returns the last valid count when the port
is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3Interval15MinSESs |
1.3.6.1.4.1.123.3.40.1.2.1.3 |
The counter associated with the number of Path Severely
Errored Seconds encountered by a E3 interface in one of
the previous 15 minute intervals.
This counts the seconds containing 34 or more BIP
errors, one or more LOF defects, one or more LOS defects,
or a detected incoming AIS. This counter is valid when
an interface is configured for Direct cell mapping.
When an interface is configured for PLCP cell mapping,
the counter returns the last valid count when the
port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3Interval15MinSEFs |
1.3.6.1.4.1.123.3.40.1.2.1.4 |
The counter associated with the number of Path Severely
Errored Frames encountered by a E3 interface in one of
the previous 15 minute intervals.
This counts framing pattern errors. In Direct cell
mapping mode, this is the count of frames with errored
FA1/FA2 bytes in the G.832 overhead. In PLCP mode,
this is the count of frames with an errored G.751
Frame Alignment byte. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3Total24HrEntry |
1.3.6.1.4.1.123.3.40.1.3.1 |
An entry in nncExtE3Total24HrTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
NncExtE3Total24HrEntry |
|
|
nncExtE3Total24HrESs |
1.3.6.1.4.1.123.3.40.1.3.1.1 |
The counter associated with the number of Path Errored
Seconds encountered by a E3 interface in the
previous 24 hours interval.
This counts the seconds containing one or more BIP
errors, one or more LOF defects, one or more LOS defects,
or a detected incoming AIS. This counter is valid when
an interface is configured for Direct cell mapping.
When an interface is configured for PLCP cell mapping,
the counter returns the last valid count when the port
is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3Total24HrSESs |
1.3.6.1.4.1.123.3.40.1.3.1.2 |
The counter associated with the number of Path Severely
Errored Seconds encountered by a E3 interface in the
previous 24 hours interval.
This counts the seconds containing 34 or more BIP
errors, one or more LOF defects, one or more LOS defects,
or a detected incoming AIS. This counter is valid when
an interface is configured for Direct cell mapping.
When an interface is configured for PLCP cell mapping,
the counter returns the last valid count when the
port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3Total24HrSEFs |
1.3.6.1.4.1.123.3.40.1.3.1.3 |
The counter associated with the number of Path Severely
Errored Frames encountered by a E3 interface in the
previous 24 hours interval.
This counts framing pattern errors. In Direct cell
mapping mode, this is the count of frames with errored
FA1/FA2 bytes in the G.832 overhead. In PLCP mode,
this is the count of frames with an errored G.751
Frame Alignment byte. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3FarEndCurrent15MinEntry |
1.3.6.1.4.1.123.3.40.1.4.1 |
An entry in nncExtE3FarEndCurrent15MinTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
NncExtE3FarEndCurrent15MinEntry |
|
|
nncExtE3FarEndCurrent15MinFEBEs |
1.3.6.1.4.1.123.3.40.1.4.1.1 |
The counter associated with the number of Far End
Block Errors encountered by a E3 interface in the
current 15 minute interval.
This is the count of received FEBEs. This counter will
not increment while failure defects are present.
This counter is valid when an interface is configured
for Direct cell mapping. When an interface is configured
for PLCP cell mapping, the counter returns the last
valid count when the port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3FarEndCurrent15MinESs |
1.3.6.1.4.1.123.3.40.1.4.1.2 |
The counter associated with the number of Far End Path
Errored Seconds encountered by a E3 interface in the
current 15 minute interval.
This counts the seconds containing one or more FEBEs.
This counter is valid when an interface is configured
for Direct cell mapping. When an interface is configured
for PLCP cell mapping, the counter returns the last
valid count when the port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3FarEndCurrent15MinSESs |
1.3.6.1.4.1.123.3.40.1.4.1.3 |
The counter associated with the number of Far End Path
Severely Errored Seconds encountered by a E3 interface
in the current 15 minute interval.
This counts the seconds containing 34 or more FEBEs.
This counter is valid when an interface is configured
for Direct cell mapping. When an interface is configured
for PLCP cell mapping, the counter returns the last
valid count when the port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3FarEndInterval15MinEntry |
1.3.6.1.4.1.123.3.40.1.5.1 |
An entry in nncExtE3FarEndInterval15MinTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
NncExtE3FarEndInterval15MinEntry |
|
|
nncExtE3FarEndInterval15MinNumber |
1.3.6.1.4.1.123.3.40.1.5.1.1 |
A number between 1 and 96, where 1 is the most recently
completed 15 minute interval and 96 is the least recently
completed 15 minutes interval (assuming that all 96
intervals are valid). |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..96 |
|
nncExtE3FarEndInterval15MinFEBEs |
1.3.6.1.4.1.123.3.40.1.5.1.2 |
The counter associated with the number of Far End
Block Errors encountered by a E3 interface in one of
the previous 15 minute intervals.
This is the count of received FEBEs. This counter will
not increment while failure defects are present.
This counter is valid when an interface is configured
for Direct cell mapping. When an interface is configured
for PLCP cell mapping, the counter returns the last
valid count when the port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3FarEndInterval15MinESs |
1.3.6.1.4.1.123.3.40.1.5.1.3 |
The counter associated with the number of Far End Path
Errored Seconds encountered by a E3 interface in one of
the previous 15 minute intervals.
This counts the seconds containing one or more FEBEs.
This counter is valid when an interface is configured
for Direct cell mapping. When an interface is configured
for PLCP cell mapping, the counter returns the last
valid count when the port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3FarEndInterval15MinSESs |
1.3.6.1.4.1.123.3.40.1.5.1.4 |
The counter associated with the number of Far End Path
Severely Errored Seconds encountered by a E3 interface
in one of the previous 15 minute intervals.
This counts the seconds containing 34 or more FEBEs.
This counter is valid when an interface is configured
for Direct cell mapping. When an interface is configured
for PLCP cell mapping, the counter returns the last
valid count when the port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3FarEndTotal24HrEntry |
1.3.6.1.4.1.123.3.40.1.6.1 |
An entry in nncExtE3FarEndTotal24HrTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
NncExtE3FarEndTotal24HrEntry |
|
|
nncExtE3FarEndTotal24HrFEBEs |
1.3.6.1.4.1.123.3.40.1.6.1.1 |
The counter associated with the number of Far End
Block Errors encountered by a E3 interface in the
previous 24 hours interval.
This is the count of received FEBEs. This counter will
not increment while failure defects are present.
This counter is valid when an interface is configured
for Direct cell mapping. When an interface is configured
for PLCP cell mapping, the counter returns the last
valid count when the port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3FarEndTotal24HrESs |
1.3.6.1.4.1.123.3.40.1.6.1.2 |
The counter associated with the number of Far End Path
Errored Seconds encountered by a E3 interface in the
previous 24 hours interval.
This counts the seconds containing one or more FEBEs.
This counter is valid when an interface is configured
for Direct cell mapping. When an interface is configured
for PLCP cell mapping, the counter returns the last
valid count when the port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3FarEndTotal24HrSESs |
1.3.6.1.4.1.123.3.40.1.6.1.3 |
The counter associated with the number of Far End Path
Severely Errored Seconds encountered by a E3 interface
in the previous 24 hours interval.
This counts the seconds containing 34 or more FEBEs.
This counter is valid when an interface is configured
for Direct cell mapping. When an interface is configured
for PLCP cell mapping, the counter returns the last
valid count when the port is in the Direct mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
nncExtE3Current15MinGroup |
1.3.6.1.4.1.123.3.40.3.1 |
Collection of objects providing 15 minute current
statistics for E3 interface. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
nncExtE3Interval15MinGroup |
1.3.6.1.4.1.123.3.40.3.2 |
Collection of objects providing 15 minute interval
statistics for E3 interface. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
nncExtE3Total24HrGroup |
1.3.6.1.4.1.123.3.40.3.3 |
Collection of objects providing previous 24 hours
statistics for E3 interface. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
nncExtE3FarEndCurrent15MinGroup |
1.3.6.1.4.1.123.3.40.3.4 |
Collection of objects providing 15 minute current
statistics for E3 interface. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
nncExtE3FarEndInterval15MinGroup |
1.3.6.1.4.1.123.3.40.3.5 |
Collection of objects providing 15 minute interval
statistics for E3 interface. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
nncExtE3FarEndTotal24HrGroup |
1.3.6.1.4.1.123.3.40.3.6 |
Collection of objects providing previous 24 hours
statistics for E3 interface. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
nncExtE3Compliance |
1.3.6.1.4.1.123.3.40.4.1 |
The compliance statement for Newbridge E3 interfaces. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|