NNCEXTE3-MIB

File: NNCEXTE3-MIB.mib (27643 bytes)

Imported modules

NNCGNI0001-SMI SNMPv2-SMI SNMPv2-CONF
IF-MIB

Imported symbols

nncExtensions MODULE-IDENTITY OBJECT-TYPE
Gauge32 Integer32 MODULE-COMPLIANCE
OBJECT-GROUP ifIndex

Defined Types

NncExtE3Current15MinEntry  
SEQUENCE    
  nncExtE3Current15MinESs Gauge32
  nncExtE3Current15MinSESs Gauge32
  nncExtE3Current15MinSEFs Gauge32

NncExtE3Interval15MinEntry  
SEQUENCE    
  nncExtE3Interval15MinNumber Integer32
  nncExtE3Interval15MinESs Gauge32
  nncExtE3Interval15MinSESs Gauge32
  nncExtE3Interval15MinSEFs Gauge32

NncExtE3Total24HrEntry  
SEQUENCE    
  nncExtE3Total24HrESs Gauge32
  nncExtE3Total24HrSESs Gauge32
  nncExtE3Total24HrSEFs Gauge32

NncExtE3FarEndCurrent15MinEntry  
SEQUENCE    
  nncExtE3FarEndCurrent15MinFEBEs Gauge32
  nncExtE3FarEndCurrent15MinESs Gauge32
  nncExtE3FarEndCurrent15MinSESs Gauge32

NncExtE3FarEndInterval15MinEntry  
SEQUENCE    
  nncExtE3FarEndInterval15MinNumber Integer32
  nncExtE3FarEndInterval15MinFEBEs Gauge32
  nncExtE3FarEndInterval15MinESs Gauge32
  nncExtE3FarEndInterval15MinSESs Gauge32

NncExtE3FarEndTotal24HrEntry  
SEQUENCE    
  nncExtE3FarEndTotal24HrFEBEs Gauge32
  nncExtE3FarEndTotal24HrESs Gauge32
  nncExtE3FarEndTotal24HrSESs Gauge32

Defined Values

nncExtE3 1.3.6.1.4.1.123.3.40
This module contains definitions for Newbridge extensions to E3 objects. It is used as a supplement to rfc1407.
MODULE-IDENTITY    

nncExtE3Objects 1.3.6.1.4.1.123.3.40.1
OBJECT IDENTIFIER    

nncExtE3Traps 1.3.6.1.4.1.123.3.40.2
OBJECT IDENTIFIER    

nncExtE3Groups 1.3.6.1.4.1.123.3.40.3
OBJECT IDENTIFIER    

nncExtE3Compliances 1.3.6.1.4.1.123.3.40.4
OBJECT IDENTIFIER    

nncExtE3Current15MinTable 1.3.6.1.4.1.123.3.40.1.1
NNC Extension to dsx3CurrentTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NncExtE3Current15MinEntry

nncExtE3Current15MinEntry 1.3.6.1.4.1.123.3.40.1.1.1
An entry in nncExtE3Current15MinTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtE3Current15MinEntry  

nncExtE3Current15MinESs 1.3.6.1.4.1.123.3.40.1.1.1.1
The counter associated with the number of Path Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3Current15MinSESs 1.3.6.1.4.1.123.3.40.1.1.1.2
The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3Current15MinSEFs 1.3.6.1.4.1.123.3.40.1.1.1.3
The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in the current 15 minute interval. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3Interval15MinTable 1.3.6.1.4.1.123.3.40.1.2
NNC Extension to dsx3IntervalTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NncExtE3Interval15MinEntry

nncExtE3Interval15MinEntry 1.3.6.1.4.1.123.3.40.1.2.1
An entry in nncExtE3Interval15MinTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtE3Interval15MinEntry  

nncExtE3Interval15MinNumber 1.3.6.1.4.1.123.3.40.1.2.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..96  

nncExtE3Interval15MinESs 1.3.6.1.4.1.123.3.40.1.2.1.2
The counter associated with the number of Path Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3Interval15MinSESs 1.3.6.1.4.1.123.3.40.1.2.1.3
The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3Interval15MinSEFs 1.3.6.1.4.1.123.3.40.1.2.1.4
The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in one of the previous 15 minute intervals. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3Total24HrTable 1.3.6.1.4.1.123.3.40.1.3
NNC Extension to dsx3TotalTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NncExtE3Total24HrEntry

nncExtE3Total24HrEntry 1.3.6.1.4.1.123.3.40.1.3.1
An entry in nncExtE3Total24HrTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtE3Total24HrEntry  

nncExtE3Total24HrESs 1.3.6.1.4.1.123.3.40.1.3.1.1
The counter associated with the number of Path Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3Total24HrSESs 1.3.6.1.4.1.123.3.40.1.3.1.2
The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3Total24HrSEFs 1.3.6.1.4.1.123.3.40.1.3.1.3
The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in the previous 24 hours interval. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3FarEndCurrent15MinTable 1.3.6.1.4.1.123.3.40.1.4
NNC Extension to dsx3FarEndCurrentTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NncExtE3FarEndCurrent15MinEntry

nncExtE3FarEndCurrent15MinEntry 1.3.6.1.4.1.123.3.40.1.4.1
An entry in nncExtE3FarEndCurrent15MinTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtE3FarEndCurrent15MinEntry  

nncExtE3FarEndCurrent15MinFEBEs 1.3.6.1.4.1.123.3.40.1.4.1.1
The counter associated with the number of Far End Block Errors encountered by a E3 interface in the current 15 minute interval. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3FarEndCurrent15MinESs 1.3.6.1.4.1.123.3.40.1.4.1.2
The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3FarEndCurrent15MinSESs 1.3.6.1.4.1.123.3.40.1.4.1.3
The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3FarEndInterval15MinTable 1.3.6.1.4.1.123.3.40.1.5
NNC Extension to dsx3FarEndIntervalTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NncExtE3FarEndInterval15MinEntry

nncExtE3FarEndInterval15MinEntry 1.3.6.1.4.1.123.3.40.1.5.1
An entry in nncExtE3FarEndInterval15MinTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtE3FarEndInterval15MinEntry  

nncExtE3FarEndInterval15MinNumber 1.3.6.1.4.1.123.3.40.1.5.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..96  

nncExtE3FarEndInterval15MinFEBEs 1.3.6.1.4.1.123.3.40.1.5.1.2
The counter associated with the number of Far End Block Errors encountered by a E3 interface in one of the previous 15 minute intervals. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3FarEndInterval15MinESs 1.3.6.1.4.1.123.3.40.1.5.1.3
The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3FarEndInterval15MinSESs 1.3.6.1.4.1.123.3.40.1.5.1.4
The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3FarEndTotal24HrTable 1.3.6.1.4.1.123.3.40.1.6
NNC Extension to dsx3FarEndTotalTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NncExtE3FarEndTotal24HrEntry

nncExtE3FarEndTotal24HrEntry 1.3.6.1.4.1.123.3.40.1.6.1
An entry in nncExtE3FarEndTotal24HrTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtE3FarEndTotal24HrEntry  

nncExtE3FarEndTotal24HrFEBEs 1.3.6.1.4.1.123.3.40.1.6.1.1
The counter associated with the number of Far End Block Errors encountered by a E3 interface in the previous 24 hours interval. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3FarEndTotal24HrESs 1.3.6.1.4.1.123.3.40.1.6.1.2
The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3FarEndTotal24HrSESs 1.3.6.1.4.1.123.3.40.1.6.1.3
The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

nncExtE3Current15MinGroup 1.3.6.1.4.1.123.3.40.3.1
Collection of objects providing 15 minute current statistics for E3 interface.
Status: current Access: read-only
OBJECT-GROUP    

nncExtE3Interval15MinGroup 1.3.6.1.4.1.123.3.40.3.2
Collection of objects providing 15 minute interval statistics for E3 interface.
Status: current Access: read-only
OBJECT-GROUP    

nncExtE3Total24HrGroup 1.3.6.1.4.1.123.3.40.3.3
Collection of objects providing previous 24 hours statistics for E3 interface.
Status: current Access: read-only
OBJECT-GROUP    

nncExtE3FarEndCurrent15MinGroup 1.3.6.1.4.1.123.3.40.3.4
Collection of objects providing 15 minute current statistics for E3 interface.
Status: current Access: read-only
OBJECT-GROUP    

nncExtE3FarEndInterval15MinGroup 1.3.6.1.4.1.123.3.40.3.5
Collection of objects providing 15 minute interval statistics for E3 interface.
Status: current Access: read-only
OBJECT-GROUP    

nncExtE3FarEndTotal24HrGroup 1.3.6.1.4.1.123.3.40.3.6
Collection of objects providing previous 24 hours statistics for E3 interface.
Status: current Access: read-only
OBJECT-GROUP    

nncExtE3Compliance 1.3.6.1.4.1.123.3.40.4.1
The compliance statement for Newbridge E3 interfaces.
Status: current Access: read-only
MODULE-COMPLIANCE