NMS-553-MIB

File: NMS-553-MIB.mib (83921 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
GDCCMN-MIB GDCMACRO-MIB

Imported symbols

Gauge OBJECT-TYPE DisplayString
gdc SCinstance

Defined Types

Nms553VersionEntry  
SEQUENCE    
  nms553VersionIndex SCinstance
  nms553FirmwareRev DisplayString

Nms553DS0AllocationSchemeEntry  
SEQUENCE    
  nms553DS0AllocationSchemeIndex SCinstance
  nms553DS0AllocationScheme INTEGER

Nms553DS0AllocationConfigEntry  
SEQUENCE    
  nms553DS0AllocationConfigIndex SCinstance
  nms553DS0AllocationBaseRate INTEGER
  nms553DS0AllocationStartingDS0 INTEGER
  nms553DS0AllocationNumberOfDS0s INTEGER
  nms553DS0AllocationInbandDccMode INTEGER

Nms553ChannelConfigEntry  
SEQUENCE    
  nms553ChannelConfigIndex SCinstance
  nms553ChannelSplitTiming INTEGER
  nms553ChannelChannelType INTEGER
  nms553ChannelClockInvert INTEGER
  nms553ChannelDataInvert INTEGER
  nms553ChannelLocalDCD INTEGER
  nms553ChannelLocalDSR INTEGER
  nms553ChannelFlowControl INTEGER
  nms553ChannelRTSCTSControl INTEGER
  nms553ChannelEIAtestLeads INTEGER
  nms553ChannelInbandLoop INTEGER
  nms553ChannelInbandLoopCode INTEGER
  nms553ChannelInbandLoopdown INTEGER
  nms553ChannelControlModeIdle INTEGER

Nms553NetworkConfigEntry  
SEQUENCE    
  nms553NetworkConfigIndex SCinstance
  nms553NetworkAdminLineType INTEGER
  nms553NetworkOperLineType INTEGER
  nms553NetworkInterfaceType INTEGER
  nms553NetworkPreequalization INTEGER
  nms553NetworkAdminLineBuildout INTEGER
  nms553NetworkOperLineBuildout INTEGER
  nms553NetworkOnesDensity INTEGER
  nms553NetworkTransmitClockSource INTEGER
  nms553NetworkFallbackClockSource INTEGER
  nms553NetworkFDLdcc INTEGER
  nms553NetworkAISLoopdown INTEGER
  nms553NetworkInbandFrame INTEGER
  nms553NetworkLoopbackConfig INTEGER
  nms553NetworkLineCoding INTEGER
  nms553NetworkFdl INTEGER

Nms553DteStatusEntry  
SEQUENCE    
  nms553DteStatusIndex SCinstance
  nms553DteStat OCTET STRING

Nms553DiagEntry  
SEQUENCE    
  nms553DiagIndex SCinstance
  nms553DiagTestDuration INTEGER
  nms553DiagProgPattern INTEGER
  nms553DiagBeginSelfTest INTEGER
  nms553DiagBeginLoopTest INTEGER
  nms553DiagTestResults INTEGER
  nms553DiagResetTestToNormal INTEGER
  nms553DiagTestStatus INTEGER

Nms553MaintenanceEntry  
SEQUENCE    
  nms553MaintenanceIndex SCinstance
  nms553LedStatus OCTET STRING
  nms553SoftReset INTEGER
  nms553DefaultInit INTEGER
  nms553FrontPanel INTEGER
  nms553ProductType INTEGER
  nms553ResetStatistics INTEGER
  nms553ValidIntervals INTEGER
  nms553CascadePresent INTEGER
  nms553ReceiveLevel INTEGER

Nms553AlarmConfigEntry  
SEQUENCE    
  nms553AlarmConfigIndex SCinstance
  nms553AlarmConfigIdentifier OBJECT IDENTIFIER
  nms553AlarmCountWindow INTEGER
  nms553AlarmCountThreshold INTEGER

Nms553AlarmHistoryEntry  
SEQUENCE    
  nms553AlarmHistoryIndex SCinstance
  nms553AlarmHistoryIdentifier OBJECT IDENTIFIER
  nms553AlarmCount Gauge
  nms553AlarmFirstOccurrenceHours INTEGER
  nms553AlarmFirstOccurrenceMinutes INTEGER
  nms553AlarmFirstOccurrenceSeconds INTEGER
  nms553AlarmFirstOccurrenceMonth INTEGER
  nms553AlarmFirstOccurrenceDay INTEGER
  nms553AlarmFirstOccurrenceYear INTEGER
  nms553AlarmLastOccurrenceHours INTEGER
  nms553AlarmLastOccurrenceMinutes INTEGER
  nms553AlarmLastOccurrenceSeconds INTEGER
  nms553AlarmLastOccurrenceMonth INTEGER
  nms553AlarmLastOccurrenceDay INTEGER
  nms553AlarmLastOccurrenceYear INTEGER

Nms553AlarmMaintenanceEntry  
SEQUENCE    
  nms553AlarmMaintenanceIndex SCinstance
  nms553ClearAlarmHistory INTEGER
  nms553RTCHours INTEGER
  nms553RTCMinutes INTEGER
  nms553RTCSeconds INTEGER
  nms553RTCMonth INTEGER
  nms553RTCDay INTEGER
  nms553RTCYear INTEGER
  nms553TimeOfLastAlarmClear OCTET STRING Size(6)

Nms553CurrentEntry  
SEQUENCE    
  nms553CurrentIndex SCinstance
  nms553CurrentESs Gauge
  nms553CurrentSESs Gauge
  nms553CurrentBESs Gauge
  nms553CurrentUASs Gauge
  nms553CurrentLOFCs Gauge
  nms553CurrentCSSs Gauge

Nms553IntervalEntry  
SEQUENCE    
  nms553IntervalIndex SCinstance
  nms553IntervalNumber INTEGER
  nms553IntervalESs Gauge
  nms553IntervalSESs Gauge
  nms553IntervalBESs Gauge
  nms553IntervalUASs Gauge
  nms553IntervalLOFCs Gauge
  nms553IntervalCSSs Gauge

Nms553TotalEntry  
SEQUENCE    
  nms553TotalIndex SCinstance
  nms553TotalESs Gauge
  nms553TotalSESs Gauge
  nms553TotalBESs Gauge
  nms553TotalUASs Gauge
  nms553TotalLOFCs Gauge
  nms553TotalCSSs Gauge

Defined Values

dsx1 1.3.6.1.4.1.498.6
OBJECT IDENTIFIER    

nms553 1.3.6.1.4.1.498.6.7
OBJECT IDENTIFIER    

nms553Version 1.3.6.1.4.1.498.6.7.1
OBJECT IDENTIFIER    

nms553DS0Allocation 1.3.6.1.4.1.498.6.7.2
OBJECT IDENTIFIER    

nms553Configuration 1.3.6.1.4.1.498.6.7.3
OBJECT IDENTIFIER    

nms553DteStatus 1.3.6.1.4.1.498.6.7.4
OBJECT IDENTIFIER    

nms553Diagnostics 1.3.6.1.4.1.498.6.7.5
OBJECT IDENTIFIER    

nms553Maintenance 1.3.6.1.4.1.498.6.7.6
OBJECT IDENTIFIER    

nms553Alarms 1.3.6.1.4.1.498.6.7.7
OBJECT IDENTIFIER    

nms553AlarmHistory 1.3.6.1.4.1.498.6.7.8
OBJECT IDENTIFIER    

nms553Performance 1.3.6.1.4.1.498.6.7.9
OBJECT IDENTIFIER    

nms553MIBversion 1.3.6.1.4.1.498.6.7.1.1
Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Upon formal release, no designation for the test revision will be present. Acceptable values for the individual revision components are as follows: x: 1 - 9, y: 0 - 9, z: 0 - 9, T: A - Z
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(5)  

nms553VersionTable 1.3.6.1.4.1.498.6.7.1.2
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553VersionEntry

nms553VersionEntry 1.3.6.1.4.1.498.6.7.1.2.1
An entry in the GDC NMS 553 Version Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553VersionEntry  

nms553VersionIndex 1.3.6.1.4.1.498.6.7.1.2.1.1
Identifies Version parameters associated with the managed object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553FirmwareRev 1.3.6.1.4.1.498.6.7.1.2.1.2
The version number of the firmware, to allow products to know which revision is installed. The released version number is sequenced from --, A-, ... AA, ... ZZ. Test versions are numerical from 01 to 99.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(2)  

nms553DS0AllocationSchemeTable 1.3.6.1.4.1.498.6.7.2.1
The GDC NMS 553 DS0 allocation table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553DS0AllocationSchemeEntry

nms553DS0AllocationSchemeEntry 1.3.6.1.4.1.498.6.7.2.1.1
The GDC NMS 553 Configuration table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553DS0AllocationSchemeEntry  

nms553DS0AllocationSchemeIndex 1.3.6.1.4.1.498.6.7.2.1.1.1
The index value which uniquely identifies the DSU to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and sub-identifier. The sub-identifier for this SC instance is the DSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553DS0AllocationScheme 1.3.6.1.4.1.498.6.7.2.1.1.2
Identifies the DSU DS0 allocation scheme.The value consecutive(2) indicates that bundles of DS0s are allocated to channels consecutively from the starting DS0. The value of alternate(3) indicates that bundles of DS0s are allocated to channels alternatly, or every other DS0 from the starting DS0. The unused DS0s are forced to marks. Note that DS0 bundles cannot be split across frames (wrap around from the highest numbered DS0 of one frame to DS0 1 of the next frame. For example, on a T1 frame using consecutive DS0 allocation, a channel configuration of starting DS0 = 20 and number of DS0s = 5 is an illegal channel configuration because the DS0 bundle wraps from DS0 #24 of 1 frame to DS0 #1 of the next.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER consecutive(1), alternate(2)  

nms553DS0AllocationConfigTable 1.3.6.1.4.1.498.6.7.2.2
The GDC DS0 Allocation Configuration table. Information in the entries of this table define the configuration of DS0 allocation for channels. There are entries in this table for each channel of the associated DSU.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553DS0AllocationConfigEntry

nms553DS0AllocationConfigEntry 1.3.6.1.4.1.498.6.7.2.2.1
The GDC DS0 Allocation Configuration table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553DS0AllocationConfigEntry  

nms553DS0AllocationConfigIndex 1.3.6.1.4.1.498.6.7.2.2.1.1
The index value which uniquely identifies the channel to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and sub-identifier. The sub-indentifier for this SCinstance is the channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553DS0AllocationBaseRate 1.3.6.1.4.1.498.6.7.2.2.1.2
Indicates the DS0 base rate: either 56K or 64K bits per second. This is used in conjunction with the number of DS0s to determine the bandwidth of the channel. Note that base rate of 64K defines the DS0 as clear channel in which all 8 bits of the DS0 are used. A base rate of 56K defines the DS0 as non-clear in which bits 1-7 are used for channel data and the 8th bit is either unused and forced to marks or used to pass signaling information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nx56k(1), nx64k(2)  

nms553DS0AllocationStartingDS0 1.3.6.1.4.1.498.6.7.2.2.1.3
Indicates the starting DS0 number for the bundle of DS0s used for the channel. DS0 bundles are allocated starting at the DS0 defined by this integer. When this integer is set to 0, the channel is disabled and no DS0s are allocated to the channel. Note that DS0 bundles cannot be split across frames (wrap around from the highest numbered DS0 of one frame to DS0 1 of the next frame. For example, on a T1 frame using consecutive DS0 allocation, a channel configuration of starting DS0 = 20 and number of DS0s = 5 is an illegal channel configuration because the DS0 bundle wraps from DS0 #24 of 1 frame to DS0 #1 of the next.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..24  

nms553DS0AllocationNumberOfDS0s 1.3.6.1.4.1.498.6.7.2.2.1.4
Indicates the number of DS0s for the bundle allocated to the channel. The number of DS0s, in conjunction with the DS0 base rate, also determines the bandwidth of the channel. Note that DS0 bundles cannot be split across frames (wrap around from the highest numbered DS0 of one frame to DS0 1 of the next frame. For example, on a T1 frame using consecutive DS0 allocation, a channel configuration of starting DS0 = 20 and number of DS0s = 5 is an illegal channel configuration because the DS0 bundle wraps from DS0 #24 of 1 frame to DS0 #1 of the next.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..24  

nms553DS0AllocationInbandDccMode 1.3.6.1.4.1.498.6.7.2.2.1.5
The mode of propagation of inband Diagnostics Communication Channel to the dedicated remote NMS553 unit. None specifies no inband DCC. Embedded is an allowed value when the mib object nms553DS0BaseRate is set to Nx56K, and specifies that DCC is propagated in the 8th bit of the assigned DS0's. dccDs0 specifies that a DS0 is used for propagation of DCC, this value would be selected if the nms553DS0BaseRate is Nx64k (clear channel) since all data bits are used for user data, a minimum of two DS0's must be assigned to this device in this mode, the last ds0 should be set as the nms553DccDs0 when using this mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), embedded(2), dccDs0(3)  

nms553ChannelConfigTable 1.3.6.1.4.1.498.6.7.3.1
The GDC 553 Channel Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553ChannelConfigEntry

nms553ChannelConfigEntry 1.3.6.1.4.1.498.6.7.3.1.1
The nms553 Channel Configuration table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553ChannelConfigEntry  

nms553ChannelConfigIndex 1.3.6.1.4.1.498.6.7.3.1.1.1
The index value which uniquely identifies the channel to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and sub-identifier. The sub-indentifier for this SCinstance is the channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553ChannelSplitTiming 1.3.6.1.4.1.498.6.7.3.1.1.2
Indicates whether or not to use split timing. The value disabled(1) indicates that channel's transmit timing is provided by the DSU. The value enabled(2) indicates that the channel's transmit timing is provided by the customer business equipment (ext Tx Clk). Split timing refers to the activation of elastic storage to allow the channel interface to receive data using the customer business equipment's timing source (ext Tx Clk) and transmit that same data to the network using the networks timing source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

nms553ChannelChannelType 1.3.6.1.4.1.498.6.7.3.1.1.3
The channel interface type. The value none(1) indicates that there is no channel interface for the index. The value v35(2) indicates the channel interface is standard V.35 and the value eia530(3) indicates the channel interface is standard EIA 530.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), v35(2), eia530(3)  

nms553ChannelClockInvert 1.3.6.1.4.1.498.6.7.3.1.1.4
Clock invert option
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER txClockNormRxClockNorm(1), txClockNormRxClockInvert(2), txClockInvertRxClockNorm(3), txClockInvertRxClockInvert(4)  

nms553ChannelDataInvert 1.3.6.1.4.1.498.6.7.3.1.1.5
Data invert option
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER txDataNormRxDataNorm(1), txDataNormRxDataInvert(2), txDataInvertRxDataNorm(3), txDataInvertRxDataInvert(4)  

nms553ChannelLocalDCD 1.3.6.1.4.1.498.6.7.3.1.1.6
Controls the operation of Data Carrier Detect (DCD) signal. The value followsSignal(1) indicates that the channel's DCD follows the inband control mode idle (CMI). The value forcedOn(2) indicates that DCD is forced on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER followsSignal(1), forcedOn(2)  

nms553ChannelLocalDSR 1.3.6.1.4.1.498.6.7.3.1.1.7
Controls the operation of the Data Set Ready (DSR) signal. The value followsSignal(1) indicates that the channel's DSR follows the inband control mode idle (CMI). The value forcedOn(2) indicates that DSR is forced on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER followsSignal(1), forcedOn(2)  

nms553ChannelFlowControl 1.3.6.1.4.1.498.6.7.3.1.1.8
Flow Control Option. This object is valid only when the control mode idle object nms553ChannelControlModeIdle is set to enabled(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER txRtsRxDcd(1), txRtsRxDsr(2), txDtrRxDcd(3), txDtrRxDsr(4)  

nms553ChannelRTSCTSControl 1.3.6.1.4.1.498.6.7.3.1.1.9
Controls the function of the channel's Request To Send (RTS) and Clear To Send signals used for flow control. The value of ctsDelay10ms(1) indicates that CTS is to respond to RTS after a 10ms delay. The value of ctsOn(2) indicates that CTS is forced on at all times. The value of ctsDelayStandard(3) indicates that CTS is to respond to RTS after the standard delay of 40 bits times. For 56Kbps applications using CMI flow control, this object must be set for ctsDelayStandard(3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ctsDelay10ms(1), ctsOn(2), ctsDelayStandard(3)  

nms553ChannelEIAtestLeads 1.3.6.1.4.1.498.6.7.3.1.1.10
Controls the channel's EIA test leads. The EIA test leads allow customer business equipment to initiate diagnostic tests through the assertion of the EIA test leads RDL, LL, and ST. When this object is enabled(1), then the assertion of these leads is recognized and acted upon by the DSU. When this object is disabled(2), then the assertion of these leads is ignored by the DSU.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

nms553ChannelInbandLoop 1.3.6.1.4.1.498.6.7.3.1.1.11
In-band loopcode enable/disable. The value disabled(1) indicates the channel does not enter an RDL loop when an inband RDL code is detected. The value enable(2) indicates the channel does enter an RDL loop when an inband RDL code is detected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enabled(2)  

nms553ChannelInbandLoopCode 1.3.6.1.4.1.498.6.7.3.1.1.12
In-band RDL code to send and/or receive by the channel. The value pn127(1) indicates that the in-band code sent/received is in accordance with CCITT V.54 PN-127 scrambled codes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pn127(1)  

nms553ChannelInbandLoopdown 1.3.6.1.4.1.498.6.7.3.1.1.13
The time limit in seconds before terminating a channel's RDL. The value inhibit(1) indicates that the loopdown time is disabled and the loopback will only terminate by the in-band loopdown code. The value enable10Min(2) indicates the time before terminating the RDL in the event the loopdown code is never received.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inhibit(1), enable10Min(2)  

nms553ChannelControlModeIdle 1.3.6.1.4.1.498.6.7.3.1.1.14
Control Mode Idle (CMI) enable/disable. When the channel application is Nx56k and RTS/CTS delay is standard, then this object defines the the use of CMI to provide flow control. The value disabled(1) indicates the channel using CMI to pass control flow information. The value enabled(2) indicates the channel is using the DDS secondary channel CMI format to pass flow control information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

nms553NetworkConfigTable 1.3.6.1.4.1.498.6.7.3.2
The GDC 553 Network Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553NetworkConfigEntry

nms553NetworkConfigEntry 1.3.6.1.4.1.498.6.7.3.2.1
The nms553 Network Configuration table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553NetworkConfigEntry  

nms553NetworkConfigIndex 1.3.6.1.4.1.498.6.7.3.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and sub-identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553NetworkAdminLineType 1.3.6.1.4.1.498.6.7.3.2.1.2
The values, in sequence, describe: 'auto' indicates the unit will determine framing. 'manEsf' indicates manual selection of extended superframe format. 'manD4'indicates manual selection of D4 framing format. 'unframed' indicates manual selection of unframed format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manEsf(2), manD4(3), unframed(4)  

nms553NetworkOperLineType 1.3.6.1.4.1.498.6.7.3.2.1.3
The values, in sequence, describe: 'manEsf' indicates the current setting of Line type. 'manD4'indicates the current setting of Line type. 'unframed' indicates the current setting of Line type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER manEsf(1), manD4(2), unframed(3)  

nms553NetworkInterfaceType 1.3.6.1.4.1.498.6.7.3.2.1.4
The operating mode of the interface. Setting the value of this object to ds1(1) configures the interface as standard DS1. Setting the value of this object to dsx1(2) configures the interface to operate as a standard cross-connect DSX-1. This object interoperates with the nms553NetworkPreequalization object. When this object is set to ds1(1), then the value of nms553NetworkPreequalization does not apply. This object interoperates with the nms553NetworkAdminLineBuildout object. When this object is set to dsx1(2), then the value of nms553NetworkLineBuildout does not apply.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ds1(1), dsx1(2)  

nms553NetworkPreequalization 1.3.6.1.4.1.498.6.7.3.2.1.5
Is the preequalization of the transmitter of the interface. This object interoperates with the object nms553NetworkInterfaceType. When the value of nms553NetworkInterfaceType is ds1(2) then this value is not applicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), preeq130(2), preeq260(3), preeq390(4), preeq530(5), preeq655(6)  

nms553NetworkAdminLineBuildout 1.3.6.1.4.1.498.6.7.3.2.1.6
This variable is used to set the Transmit Ntwk Build-Out value on the network side and is only valid if the nms553NetworkInterfaceType is set for ds1(1). The values, in sequence, describe: auto(1) indicates auto detection of receive level to determine the appropriate Ntwk build out without controller intervention man00dB(2) indicates manual selection of 0.0 dB transmit Ntwk build out man75dB(3) indicates manual selection of -7.5 dB transmit Ntwk build out man150dB(4) indicates manual selection of -15.0 dB transmit Ntwk build out
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), man00dB(2), man75dB(3), man150dB(4)  

nms553NetworkOperLineBuildout 1.3.6.1.4.1.498.6.7.3.2.1.7
This variable is used to report the current Ntwk build-out setting if the nms553NetworkInterfaceType is set for ds1(1). tx00dB(1) indicates the unit is set for 0.0 dB of attenuation when the nms553NetworkAdminLineBuildout is set for auto (1) or man00dB (2) tx75dB(2) indicates the unit is set for -7.5 dB of attenuation when the nms553NetworkAdminLineBuildout is set for auto (1) or man75dB (3) tx150dB(3) indicates the unit is set for -15.0 dB of attenuation when the nms553NetworkAdminLineBuildout is set for auto (1) or man150dB (4)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tx00dB(1), tx75dB(2), tx150dB(3)  

nms553NetworkOnesDensity 1.3.6.1.4.1.498.6.7.3.2.1.8
The ones density restriction for the interface. The values of this object define the ones density restriction that is enforced on the interface. The value inhibit(1) indicates that no ones density restriction is enforced. The value max15zeros(2) indicates that a maximum of 15 zeros are transmitted to the network before a one is inserted. The value max39zeros(3) indicates that a maximum of 39 zeros are transmitted to the network before a one is inserted. The value restrict8nX1(4) indicates a minimum of N ones per 8(N+1) bits, where N is in the range 1 to 24. The value min1in8(5) indicates a minimum of 1 one per 8 bits. With this value, pulse density violations are enforced but not recorded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inhibit(1), max15zeros(2), max39zeros(3), restrict8XNplus1(4), min1in8(5)  

nms553NetworkTransmitClockSource 1.3.6.1.4.1.498.6.7.3.2.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER receive(1), cascade(2), internal(3), station(4), extChannelClkA(5), extChannelClkB(6), extChannelClkC(7), composite(8)  

nms553NetworkFallbackClockSource 1.3.6.1.4.1.498.6.7.3.2.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER receive(1), internal(2)  

nms553NetworkFDLdcc 1.3.6.1.4.1.498.6.7.3.2.1.11
Controls whether or not the DCC uses the FDL as its transport. The FDL is only available when the DS1 line type is ESF, a full DS1 interface is being used, and transportation of the FDL completely through the network is supported. The value enabled(1) enables the transportation of the DCC using the FDL. The value disabled(2) disables the use of the FDL to transport the DCC, which implies that the DCC is transported by some other means. This object interoperates with the nms553NetworkLineType object. The value of this object can be set to enabled(1) only when the value of the nms553NetworkLineType is one of the ESF values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

nms553NetworkAISLoopdown 1.3.6.1.4.1.498.6.7.3.2.1.12
The time in seconds when receiving a continuous AIS signal before a remotely initiated loopback is terminated. When this object has the value 4, then there is no time limit and the loop must be terminated by remotely issued in-band loopdown codes. When the object has a value between 5 and 60, then this is time in seconds of continuous AIS signal before the loopback is terminated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..60  

nms553NetworkInbandFrame 1.3.6.1.4.1.498.6.7.3.2.1.13
This variable is used to set the In-Band DS1 Loopback Code Detection. Framed(1) framing is done upon recognition of he inband loopback code. Unframed(2) no framing is done upon recognition of the inband loopback code.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER framed(1), unframed(2)  

nms553NetworkLoopbackConfig 1.3.6.1.4.1.498.6.7.3.2.1.14
This variable is used to set the In-Band DS1 Loopback Code Detection. none(1) refers to when the in-band loopback codes are ignored. payload(2) designates a payload loopback is done upon recognition of the inband loopback code. lineloop(3) designates a line loopback is done upon recognition of the inband loopback code.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), payload(2), lineloop(3)  

nms553NetworkLineCoding 1.3.6.1.4.1.498.6.7.3.2.1.15
This variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteristics. nms553B8ZS refers to the use of a specified pat- tern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits. nms553AMI refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density re- quirements, such as inverting HDLC data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nms553B8ZS(1), nms553AMI(2)  

nms553NetworkFdl 1.3.6.1.4.1.498.6.7.3.2.1.16
This bitmap describes the use of the facili- ties data link, and is the sum of the capabili- ties: nms553Fdl-none(1) indicates that the device does not use the FDL. nms553Ansi-T1-403(2) refers to the FDL exchange recommended by ANSI. nms553Att-54016(3) refers to ESF FDL exchanges.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nms553Fdl-none(1), nms553Ansi-T1-403(2), nms553Att-54016(3)  

nms553ConfigurationSave 1.3.6.1.4.1.498.6.7.3.3
This variable is used to set the update status flag for saving network and channel configuration settings. Management can only set to network(1), channel(2), or both(3) A norm(4) will always be read. Both Network configuration and Channel configuration are saved at the same time on both(3). Configuration settings are not saved to network element by default. This permits the configuration of several objects before saving. After all objects are set-up, a (1),(2) or (3) must be sent. This will enable and save the new configuration(s).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER network(1), channel(2), both(3), norm(4)  

nms553DteStatusTable 1.3.6.1.4.1.498.6.7.4.1
The nms553 DTE Signal Status table. Information in the entries of this table define the status of DSU channel interface leads. There are entries in this table for each channel of the associated DSU.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553DteStatusEntry

nms553DteStatusEntry 1.3.6.1.4.1.498.6.7.4.1.1
The nms553 DTE Signal Status table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553DteStatusEntry  

nms553DteStatusIndex 1.3.6.1.4.1.498.6.7.4.1.1.1
The index value: slot, line, drop, and interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553DteStat 1.3.6.1.4.1.498.6.7.4.1.1.2
Returns a bitwise snapshot of the DTE signals. Octet 1 bit 7 - not used bit 6 - CTS (1:ON; 0:OFF) bit 5 - RTS (1:ON; 0:OFF) bit 4 - DTR (1:ON; 0:OFF) bit 3 - DSR (1:ON; 0:OFF) bit 2 - future use bit 1 - DCD (1:ON; 0:OFF) bit 0 - future use Octet 2 bit 7 - not used bit 6 - RXC (1:Transitions) bit 5 - DCD (1:Transitions) bit 4 - RTS (1:Transitions) bit 3 - CTS (1:Transitions) bit 2 - RXD (1:Transitions) bit 1 - TXC (1:Transitions) bit 0 - TXD (1:Transitions)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

nms553DiagTable 1.3.6.1.4.1.498.6.7.5.1
The NMS 553 Diagnostics table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553DiagEntry

nms553DiagEntry 1.3.6.1.4.1.498.6.7.5.1.1
The SNMP553S Diagnostics table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553DiagEntry  

nms553DiagIndex 1.3.6.1.4.1.498.6.7.5.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and sub-identifier, which in this case is a network interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553DiagTestDuration 1.3.6.1.4.1.498.6.7.5.1.1.2
Selects the duration to run a diagnostic test. The value(1) noLimit signifies that the test should run indefinitely until explicitly terminated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER testTime30Secs(1), testTime1Min(2), testTime2Mins(3), testTime3Mins(4), testTime4Mins(5), testTime5Mins(6), testTime6Mins(7), testTime7Mins(8), testTime8Mins(9), testTime9Mins(10), testTime10Mins(11), testTime15Mins(12), testTime20Mins(13), testTime25Mins(14), testTime30Mins(15), noLimit(16)  

nms553DiagProgPattern 1.3.6.1.4.1.498.6.7.5.1.1.3
The 16 bit user programmable test pattern. This object works with the nms553DiagSendCode object in that when nms553DiagSendCode is set to sendProgPattern(4), the the value of this object is used as the 16 bit user programmable test pattern. This object is used for all tests defined in both the GDC dsx1 mib.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..ffff  

nms553DiagBeginSelfTest 1.3.6.1.4.1.498.6.7.5.1.1.4
A set of 1-8 will start the selected test with the indicated pattern. A 9 cannot be set by management. A read will always return a 9.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unit511Pattern(1), unit2047Pattern(2), unitQRSPattern(3), unitProgPattern(4), dsu511Pattern(5), dsu2047Pattern(6), dsuQRSPattern(7), dsuProgPattern(8), noselftestrunning(9)  

nms553DiagBeginLoopTest 1.3.6.1.4.1.498.6.7.5.1.1.5
A set will start the selected test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER localLoopback(1), digitalLoopback(2), remoteDigitalLoopback(3), nolooptestrunning(4)  

nms553DiagTestResults 1.3.6.1.4.1.498.6.7.5.1.1.6
The results of the last diagnostic test. This can be the current test running or the last completed test. The units of the value of this object depend on the type of diagnostic test run. For all cases except a network delay measurement, the units of the value of this object is the number of bit errors that occurred. Bit errors can be read at any time during the duration of the test. The valid range for bit errors is 0 to 4,095. 65,535 will be returned if for any reason the test was terminated early. 32,770 will be returned if the number of bit errors exceeds 4,095. For a network delay measurement, the units of the value of this test are milliseconds. If the test is terminated early then 65,535 will be returned and if the delay is greater than 4,095 then 32,770 will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553DiagResetTestToNormal 1.3.6.1.4.1.498.6.7.5.1.1.7
This object will halt the execution of any and all diagnostic test that may be running with the exception of the Network Delay Test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), resetTest(2)  

nms553DiagTestStatus 1.3.6.1.4.1.498.6.7.5.1.1.8
This object will return the test current test in progress, if any.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noTestinProgress(1), unitSelfTest(2), dsuSelfTest(3), localLoopback(4), digitalLoopback(5)  

nms553MaintenanceTable 1.3.6.1.4.1.498.6.7.6.1
The table describes the maintenance functions for the nms553.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553MaintenanceEntry

nms553MaintenanceEntry 1.3.6.1.4.1.498.6.7.6.1.1
An entry in the GDC maintenance Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553MaintenanceEntry  

nms553MaintenanceIndex 1.3.6.1.4.1.498.6.7.6.1.1.1
The index value: slot, line, drop, and interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553LedStatus 1.3.6.1.4.1.498.6.7.6.1.1.2
Returns a bitwise snapshot of the front panel LED state and front panel switches. Octet 1 bit 7 - not used bit 6 - ON (0:LED inactive 1:LED active) bit 5 - DSX1 bit 4 - NMSRSP bit 3 - NMSDAT bit 2 - ER bit 1 - DSX OOF bit 0 - DSX LOS Octet 2 bit 7 - not used bit 6 - NET OOF bit 5 - NET LOS bit 4 - NET BPV bit 3 - NET AIS bit 2 - TM/ALM bit 1 - LBK bit 0 - future use Octet 3 bit 7 - not used bit 6 - CHA SD bit 5 - CHA RD bit 4 - CHB SD bit 3 - CHB RD bit 2 - CHC SD bit 1 - CHC RD bit 0 - future use
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

nms553SoftReset 1.3.6.1.4.1.498.6.7.6.1.1.3
Supports the action of soft resetting the unit. When this object is set to reset(1), then the unit performs a soft reset. The value norm will be returned when the reset is complete. The value of norm can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), norm(2)  

nms553DefaultInit 1.3.6.1.4.1.498.6.7.6.1.1.4
This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault, the unit will reset to the default configuration. The value of normal will be returned when the initialization is complete. The value normal can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER factoryDefault(1), normal(2)  

nms553FrontPanel 1.3.6.1.4.1.498.6.7.6.1.1.5
This variable is used to indicate whether the front panel switches are operational or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inhibit(1), enable(2)  

nms553ProductType 1.3.6.1.4.1.498.6.7.6.1.1.6
Indicates the product type of the unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER nms553d1(1), nms553d1ifp(2), nms553d3ifp(3), nms553c(4), nms553cifp(5)  

nms553ResetStatistics 1.3.6.1.4.1.498.6.7.6.1.1.7
Supports the action of soft resetting the nms553ValidIntervals object. When this object is set to reset(2), then the unit will reset the nms553ValidIntervals object to zero. The value of norm(1) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

nms553ValidIntervals 1.3.6.1.4.1.498.6.7.6.1.1.8
The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought on-line within the last 24 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..96  

nms553CascadePresent 1.3.6.1.4.1.498.6.7.6.1.1.9
Identifies whether or not the cascade interface cards are installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

nms553ReceiveLevel 1.3.6.1.4.1.498.6.7.6.1.1.10
This variable reports the absolute value of the network relative receive level of -40dB to +3dB when the nms553networkInterfaceType is set for ds1(1). Values 1 thru 40 are to be interpreted as negative values, example a value 10 equals -10dB. Values 41,42,43 are to be interpreted as +1,+2 and +3dB respectively.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..43  

nms553AlarmData 1.3.6.1.4.1.498.6.7.7.1
OBJECT IDENTIFIER    

nms553NoResponseAlm 1.3.6.1.4.1.498.6.7.7.1.1
OBJECT IDENTIFIER    

nms553DiagRxErrAlm 1.3.6.1.4.1.498.6.7.7.1.2
OBJECT IDENTIFIER    

nms553PowerUpAlm 1.3.6.1.4.1.498.6.7.7.1.3
OBJECT IDENTIFIER    

nms553NvRamCorrupt 1.3.6.1.4.1.498.6.7.7.1.4
OBJECT IDENTIFIER    

nms553UnitFailure 1.3.6.1.4.1.498.6.7.7.1.5
OBJECT IDENTIFIER    

nms553TimingLoss 1.3.6.1.4.1.498.6.7.7.1.6
OBJECT IDENTIFIER    

nms553StatusChange 1.3.6.1.4.1.498.6.7.7.1.7
OBJECT IDENTIFIER    

nms553UnsolicitedTest 1.3.6.1.4.1.498.6.7.7.1.8
OBJECT IDENTIFIER    

nms553LossOfSignal 1.3.6.1.4.1.498.6.7.7.1.9
OBJECT IDENTIFIER    

nms553LossOfFrame 1.3.6.1.4.1.498.6.7.7.1.10
OBJECT IDENTIFIER    

nms553AlarmIndicationSignal 1.3.6.1.4.1.498.6.7.7.1.11
OBJECT IDENTIFIER    

nms553ReceivedYellow 1.3.6.1.4.1.498.6.7.7.1.12
OBJECT IDENTIFIER    

nms553UnavailableSignalState 1.3.6.1.4.1.498.6.7.7.1.13
OBJECT IDENTIFIER    

nms553ExcessiveZeros 1.3.6.1.4.1.498.6.7.7.1.14
OBJECT IDENTIFIER    

nms553LowAverageDensity 1.3.6.1.4.1.498.6.7.7.1.15
OBJECT IDENTIFIER    

nms553ControlledSlips 1.3.6.1.4.1.498.6.7.7.1.16
OBJECT IDENTIFIER    

nms553BipolarViolations 1.3.6.1.4.1.498.6.7.7.1.17
OBJECT IDENTIFIER    

nms553CrcErrors 1.3.6.1.4.1.498.6.7.7.1.18
OBJECT IDENTIFIER    

nms553AlarmConfigTable 1.3.6.1.4.1.498.6.7.7.2
The nms553AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553AlarmConfigEntry

nms553AlarmConfigEntry 1.3.6.1.4.1.498.6.7.7.2.1
An entry in the GDC Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553AlarmConfigEntry  

nms553AlarmConfigIndex 1.3.6.1.4.1.498.6.7.7.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553AlarmConfigIdentifier 1.3.6.1.4.1.498.6.7.7.2.1.2
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

nms553AlarmCountWindow 1.3.6.1.4.1.498.6.7.7.2.1.3
This variable sets/reads the BPV alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), last1sec(2), last1min(3), last1hr(4), infinite(5)  

nms553AlarmCountThreshold 1.3.6.1.4.1.498.6.7.7.2.1.4
This function sets/reads the BPV alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thresGT10(1), thresGT100(2), thresGT1000(3), thresGT10000(4)  

nms553AlarmHistoryTable 1.3.6.1.4.1.498.6.7.8.1
The nms553AlarmHistoryTable contains entries that report the history of all supported alarms. The history consists of the the number of times the alarm has occurred since last history reset, the time of the first alarm occurence (hours,minutes, seconds,day,month,year), and the time of the last alarm occurrence (hours,minutes,seconds,day,month,year). The structure of the table is such that alarm status is supported on a unit or interface basis, and then on an alarm type basis within the interface. For simplicity sake and to support the reporting of status of all alarms, a unit is treated as an interface 1 in this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553AlarmHistoryEntry

nms553AlarmHistoryEntry 1.3.6.1.4.1.498.6.7.8.1.1
An entry in the GDC NMS553 Alarm History table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553AlarmHistoryEntry  

nms553AlarmHistoryIndex 1.3.6.1.4.1.498.6.7.8.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553AlarmHistoryIdentifier 1.3.6.1.4.1.498.6.7.8.1.1.2
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

nms553AlarmCount 1.3.6.1.4.1.498.6.7.8.1.1.3
The number of occurrences of this alarm. This objects value is incremented once for each time that the alarm occurs. This count is incremented regardless of whether or not the alarm is masked or is not reporteded because of the threshold configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553AlarmFirstOccurrenceHours 1.3.6.1.4.1.498.6.7.8.1.1.4
The hour (0-23) the alarm first occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmFirstOccurrenceMinutes 1.3.6.1.4.1.498.6.7.8.1.1.5
The minute (0-59) the alarm first occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmFirstOccurrenceSeconds 1.3.6.1.4.1.498.6.7.8.1.1.6
The second (0-59) the alarm first occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmFirstOccurrenceMonth 1.3.6.1.4.1.498.6.7.8.1.1.7
The month (1-12) the alarm first occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmFirstOccurrenceDay 1.3.6.1.4.1.498.6.7.8.1.1.8
The day (1-31) the alarm first occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmFirstOccurrenceYear 1.3.6.1.4.1.498.6.7.8.1.1.9
The year (0-99) the alarm first occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmLastOccurrenceHours 1.3.6.1.4.1.498.6.7.8.1.1.10
The hour (0-23) the alarm last occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmLastOccurrenceMinutes 1.3.6.1.4.1.498.6.7.8.1.1.11
The minute (0-59) the alarm last occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmLastOccurrenceSeconds 1.3.6.1.4.1.498.6.7.8.1.1.12
The second (0-59) the alarm last occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmLastOccurrenceMonth 1.3.6.1.4.1.498.6.7.8.1.1.13
The month (1-12) the alarm last occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmLastOccurrenceDay 1.3.6.1.4.1.498.6.7.8.1.1.14
The day (1-31) the alarm last occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmLastOccurrenceYear 1.3.6.1.4.1.498.6.7.8.1.1.15
The year (0-99) the alarm last occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nms553AlarmMaintenanceTable 1.3.6.1.4.1.498.6.7.8.2
The nms553AlarmMaintenanceTable contains entries that configure the real time clock and that clear the alarm history table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553AlarmMaintenanceEntry

nms553AlarmMaintenanceEntry 1.3.6.1.4.1.498.6.7.8.2.1
An entry in the GDC nms553 Alarm Maintenance Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553AlarmMaintenanceEntry  

nms553AlarmMaintenanceIndex 1.3.6.1.4.1.498.6.7.8.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553ClearAlarmHistory 1.3.6.1.4.1.498.6.7.8.2.1.2
Supports the action of clearing the alarm history table. When this object is set to clear(1), then the unit clears the alarm history table. The value of norm(2) will be returned when the clear is complete. The value of norm(2) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), norm(2)  

nms553RTCHours 1.3.6.1.4.1.498.6.7.8.2.1.3
The hour of day (0-23) to be set or read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nms553RTCMinutes 1.3.6.1.4.1.498.6.7.8.2.1.4
The minute of the hour (0-59) to be set or read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nms553RTCSeconds 1.3.6.1.4.1.498.6.7.8.2.1.5
The second of the minute (0-59) to be set or read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nms553RTCMonth 1.3.6.1.4.1.498.6.7.8.2.1.6
The month of the year (1-12) to be set or read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nms553RTCDay 1.3.6.1.4.1.498.6.7.8.2.1.7
The day of the month (1-31) to be set or read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nms553RTCYear 1.3.6.1.4.1.498.6.7.8.2.1.8
The year (0-99) to be set or read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nms553TimeOfLastAlarmClear 1.3.6.1.4.1.498.6.7.8.2.1.9
Returns the time (hours,minutes,seconds,month,day,year) of the last alarm clear command sent to the unit. Octet 1 - Hour of last alarm clear (0-23) Octet 2 - Minute of last alarm clear (0-59) Octet 3 - Second of last alarm clear (0-59) Octet 4 - Month of last alarm clear (1-12) Octet 5 - Day of last alarm clear (1-31) Octet 6 - Year of last alarm clear (0-99).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

nms553CurrentTable 1.3.6.1.4.1.498.6.7.9.1
The nms553 Current table. This table supplements the entries in the DS1 AT&T performance table of the DS1 MIB defined in RFC1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553CurrentEntry

nms553CurrentEntry 1.3.6.1.4.1.498.6.7.9.1.1
An entry in the nms553 Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553CurrentEntry  

nms553CurrentIndex 1.3.6.1.4.1.498.6.7.9.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a network interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553CurrentESs 1.3.6.1.4.1.498.6.7.9.1.1.2
The number of Errored Seconds, encountered by a DS1 interface in the current 15 minute inter- val.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553CurrentSESs 1.3.6.1.4.1.498.6.7.9.1.1.3
The number of Severely Errored Seconds encoun- tered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553CurrentBESs 1.3.6.1.4.1.498.6.7.9.1.1.4
The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553CurrentUASs 1.3.6.1.4.1.498.6.7.9.1.1.5
The number of Unavailable Seconds encountered by a DS1 interface in the current 15 minute in- terval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553CurrentLOFCs 1.3.6.1.4.1.498.6.7.9.1.1.6
The number of Loss of Frame Counts (LOFCs) encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553CurrentCSSs 1.3.6.1.4.1.498.6.7.9.1.1.7
The number of Controlled Slip Seconds encoun- tered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553IntervalTable 1.3.6.1.4.1.498.6.7.9.2
The nms553 Interval table. This table supplements the entries in the DS1 AT&T performance table of the DS1 MIB defined in RFC1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553IntervalEntry

nms553IntervalEntry 1.3.6.1.4.1.498.6.7.9.2.1
An entry in the DS1 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553IntervalEntry  

nms553IntervalIndex 1.3.6.1.4.1.498.6.7.9.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a network interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553IntervalNumber 1.3.6.1.4.1.498.6.7.9.2.1.2
A number between 1 and 96, where 1 is the most recently completed minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

nms553IntervalESs 1.3.6.1.4.1.498.6.7.9.2.1.3
The number of Errored Seconds encountered by a DS1 interface in one of the previous 96, indi- vidual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553IntervalSESs 1.3.6.1.4.1.498.6.7.9.2.1.4
The number of Severely Errored Seconds encoun- tered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553IntervalBESs 1.3.6.1.4.1.498.6.7.9.2.1.5
The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553IntervalUASs 1.3.6.1.4.1.498.6.7.9.2.1.6
The number of Unavailable Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553IntervalLOFCs 1.3.6.1.4.1.498.6.7.9.2.1.7
The number of Loss of Frame Counts (LOFCs) encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553IntervalCSSs 1.3.6.1.4.1.498.6.7.9.2.1.8
The number of Controlled Slip Seconds encoun- tered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553TotalTable 1.3.6.1.4.1.498.6.7.9.3
The DS1 Total table. 24 hour interval. This table supplements the entries in the DS1 AT&T performance table of the DS1 MIB defined in RFC1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Nms553TotalEntry

nms553TotalEntry 1.3.6.1.4.1.498.6.7.9.3.1
An entry in the DS1 Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Nms553TotalEntry  

nms553TotalIndex 1.3.6.1.4.1.498.6.7.9.3.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a network interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

nms553TotalESs 1.3.6.1.4.1.498.6.7.9.3.1.2
The number of Errored Seconds encountered by a DS1 interface in the previous 24 hour interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553TotalSESs 1.3.6.1.4.1.498.6.7.9.3.1.3
The number of Severely Errored Seconds encoun- tered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553TotalBESs 1.3.6.1.4.1.498.6.7.9.3.1.4
The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553TotalUASs 1.3.6.1.4.1.498.6.7.9.3.1.5
The number of Unavailable Seconds encountered by a DS1 interface in the previous 24 hour in- terval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553TotalLOFCs 1.3.6.1.4.1.498.6.7.9.3.1.6
The number of Loss of Frame Counts (LOFCs) encountered by a DS1interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nms553TotalCSSs 1.3.6.1.4.1.498.6.7.9.3.1.7
The number of Controlled Slip Seconds encoun- tered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge