NLS-BBNSTATE-MIB

File: NLS-BBNSTATE-MIB.mib (9567 bytes)

Imported modules

NLS-BBNIDENT-MIB RFC-1212

Imported symbols

bbnState OBJECT-TYPE

Defined Values

unitAdministrativeState 1.3.6.1.4.1.1166.5.2.1
This state should be always supported. The current Adminsitrative state of the unit is defined in ISO/IEC 10164-2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER locked(1), unlocked(2), shuttingDown(3)  

unitOperationalState 1.3.6.1.4.1.1166.5.2.2
The current Operational state of the unit as defined in ISO/IEC 10164-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

unitUsageState 1.3.6.1.4.1.1166.5.2.3
The current Usage state of the unit as defined in ISO/IEC 10164-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), active(2), busy(3)  

unitProceduralStatus 1.3.6.1.4.1.1166.5.2.4
This state should be always supported. This object controls the Procedural status as defined in ISO/IEC 10164-2 and state-machine
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER initializationRequired(1), notInitialized(2), initializing(3), reporting(4), terminating(5), ready(6)  

unitAlarmStatus 1.3.6.1.4.1.1166.5.2.5
This state should be always supported. This object defines the Alarm status as defined in ISO/IEC 10164-2 and state-machine
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6), underRepair(7), alarmOutstanding(8), idle(9)  

unitAvailabilityStatus 1.3.6.1.4.1.1166.5.2.6
This object controls the Availability status as defined in ISO/IEC 10164-2 and state-machine
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inTest(1), failed(2), powerOff(3), offLine(4), offDuty(5), dependency(6), degraded(7), notInstalled(8), logFull(9), available(10)  

unitControlStatus 1.3.6.1.4.1.1166.5.2.7
This object controls the Control status as defined in ISO/IEC 10164-2 and state-machine
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER subjectToTest(32767), partLocked(1), reservedToTest(2), suspended(3), free(4)  

unitStandbyStatus 1.3.6.1.4.1.1166.5.2.8
This object controls the Standby status as defined in ISO/IEC 10164-2 and state-machine
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hotStandby(1), coldStandby(2), providingService(3)  

unitUnknownStatus 1.3.6.1.4.1.1166.5.2.9
This object defines the unknown status as defined in ISO/IEC 10164-2 and state-machine
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)