NEXANS-BM-MIB

File: NEXANS-BM-MIB.mib (70591 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC NEXANS-MIB

Imported symbols

MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
Integer32 IpAddress Counter32
MacAddress DisplayString nexansANS

Defined Types

PortEntry  
SEQUENCE    
  portIndex Integer32
  portDescr DisplayString
  portName DisplayString
  portAdminState INTEGER
  portSpeedDuplexSetup INTEGER
  portLinkState INTEGER
  portErrorCounter Counter32
  portRemoteFault INTEGER
  portDefaultVlanId Integer32
  portTrunkingMode INTEGER
  portDot1qDefaultPrioValue Integer32
  portDefaultPrioQueue Integer32
  portLEDGreen INTEGER
  portLEDYellow INTEGER
  portBandwidthLimitRxd INTEGER
  portBandwidthLimitTxd INTEGER
  portSecurityAdminState INTEGER
  portSecurityMacAddr1 MacAddress
  portSecurityMacAddr2 MacAddress
  portSecurityMacAddr3 MacAddress
  portPoeAdminState INTEGER
  portPoeVoltage Integer32
  portPoeCurrent Integer32
  portPoePower Integer32
  portSecurityForwardingState INTEGER
  portPoePowerLimit Integer32
  portLimiterPacketType INTEGER
  portAcApSetup INTEGER
  portLinkType INTEGER
  portVoiceVlanId Integer32
  portPrioDot1p INTEGER
  portPrioIp INTEGER

PortStatus  
SEQUENCE    
  portIndex Integer32
  portDescr DisplayString
  portName DisplayString
  portLinkType INTEGER
  portAdminState INTEGER
  portSpeedDuplexSetup INTEGER
  portAcApSetup INTEGER
  portLinkState INTEGER
  portErrorCounter Counter32
  portRemoteFault INTEGER

PortVlan  
SEQUENCE    
  portIndex Integer32
  portDescr DisplayString
  portName DisplayString
  portDefaultVlanId Integer32
  portVoiceVlanId Integer32
  portTrunkingMode INTEGER

PortPrio  
SEQUENCE    
  portIndex Integer32
  portDescr DisplayString
  portName DisplayString
  portDot1qDefaultPrioValue Integer32
  portDefaultPrioQueue Integer32
  portPrioDot1p INTEGER
  portPrioIp INTEGER

PortLEDs  
SEQUENCE    
  portIndex Integer32
  portDescr DisplayString
  portName DisplayString
  portLEDGreen INTEGER
  portLEDYellow INTEGER

PortSecurity  
SEQUENCE    
  portIndex Integer32
  portDescr DisplayString
  portName DisplayString
  portAdminState INTEGER
  portSecurityAdminState INTEGER
  portSecurityForwardingState INTEGER
  portSecurityMacAddr1 MacAddress
  portSecurityMacAddr2 MacAddress
  portSecurityMacAddr3 MacAddress

PortBandwidthLimiter  
SEQUENCE    
  portIndex Integer32
  portDescr DisplayString
  portName DisplayString
  portBandwidthLimitRxd INTEGER
  portBandwidthLimitTxd INTEGER
  portLimiterPacketType INTEGER

PortPoe  
SEQUENCE    
  portIndex Integer32
  portDescr DisplayString
  portName DisplayString
  portLEDYellow INTEGER
  portPoeAdminState INTEGER
  portPoeVoltage Integer32
  portPoeCurrent Integer32
  portPoePower Integer32
  portPoePowerLimit Integer32

VlanEntry  
SEQUENCE    
  vlanIndex Integer32
  vlanId Integer32
  vlanDescr DisplayString

SfpEntry  
SEQUENCE    
  sfpPortIndex Integer32
  sfpState INTEGER
  sfpInfoVendorName DisplayString
  sfpInfoPartNumber DisplayString
  sfpInfoRevisionNumber DisplayString
  sfpInfoSerialNumber DisplayString
  sfpInfoDateCode DisplayString
  sfpInfoBitRate DisplayString
  sfpInfoWavelength DisplayString
  sfpInfoLength9um DisplayString
  sfpInfoLength50um DisplayString
  sfpInfoLength62um DisplayString
  sfpInfoConnectorDescr DisplayString
  sfpDiagTemperature Integer32
  sfpDiagSupplyVoltage Integer32
  sfpDiagTxBiasCurrent Integer32
  sfpDiagTxOutputPower Integer32
  sfpDiagTxOutputPowerDbm Integer32
  sfpDiagRxIntputPower Integer32
  sfpDiagRxInputPowerDbm Integer32
  sfpAlarmTxBiasCurrentUpperLimit Integer32
  sfpAlarmTxOutputPowerLowerLimit Integer32
  sfpAlarmRxInputPowerLowerLimit Integer32

Defined Values

bmSwitchMIB 1.3.6.1.4.1.266.20
MIB for Nexans switches
MODULE-IDENTITY    

bmTraps 1.3.6.1.4.1.266.20.0
OBJECT IDENTIFIER    

bmSwitchInfo 1.3.6.1.4.1.266.20.1
OBJECT IDENTIFIER    

bmSwitchAdmin 1.3.6.1.4.1.266.20.2
OBJECT IDENTIFIER    

bmSwitchPort 1.3.6.1.4.1.266.20.3
OBJECT IDENTIFIER    

bmSwitchVlan 1.3.6.1.4.1.266.20.4
OBJECT IDENTIFIER    

bmSwitchSfp 1.3.6.1.4.1.266.20.5
OBJECT IDENTIFIER    

infoDescr 1.3.6.1.4.1.266.20.1.1
The ordering description of the switch
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..40)  

infoType 1.3.6.1.4.1.266.20.1.2
The infoType indentifies the product familie of this switch. Refer to NEXANS-MIB for the currently defined families
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

infoProductNo 1.3.6.1.4.1.266.20.1.3
The product number of the switch (8830xxxx)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

infoSerie 1.3.6.1.4.1.266.20.1.4
The production series of the switch
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..6)  

infoSeriesNo 1.3.6.1.4.1.266.20.1.5
The production number of the switch
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..6)  

infoManufactureDate 1.3.6.1.4.1.266.20.1.6
The manufacturing date of the switch. The display format is dd.mm.jjjj
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(10)  

infoSwitchHardwareVersion 1.3.6.1.4.1.266.20.1.7
The hardware version of the base switch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..6)  

infoMgmtHardwareVersion 1.3.6.1.4.1.266.20.1.8
The hardware version of the plug-in management module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..6)  

infoMgmtFirmwareVersion 1.3.6.1.4.1.266.20.1.9
The firmware version of the management module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

infoNoOfPorts 1.3.6.1.4.1.266.20.1.10
The number of switching ports within the system. This includes all user and uplink ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

infoNoOfReboots 1.3.6.1.4.1.266.20.1.11
The number of reboots since the manufacturing date. This counter can't be cleared by any admin command.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

infoTemperature 1.3.6.1.4.1.266.20.1.12
The case temperature in degree Celsius of the switch.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

infoTemperatureMaxAllowed 1.3.6.1.4.1.266.20.1.13
The upper limit of the allowed temperature range in degree Celsius. If the current temperature indicated by infoTemperature exceeds infoTemperatureMaxAllowed, the switch sends an switchOverTemperature alarm trap.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

infoPowerVoltage2500 1.3.6.1.4.1.266.20.1.14
The 2.5 volt supply voltage in millivolts. The allowed range is 2300...2700 millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

infoPowerVoltage3300 1.3.6.1.4.1.266.20.1.15
The 3.3 volt supply voltage in millivolts. The allowed range is 3100...3500 millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

infoUnauthIpAddr 1.3.6.1.4.1.266.20.1.16
The source IP address of the station which generated the last authentication failure. The infoUnauthAddr is also reported in the switchMgmtAuthFailure alarm trap.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

infoSecurityFailMacAddr 1.3.6.1.4.1.266.20.1.17
The source MAC address of the station which has generated a the last port security failure. The infoSecurityFailMacAddr is also reported in the portSecurityFailure alarm trap.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..12)  

infoNewMacAddr 1.3.6.1.4.1.266.20.1.18
The last new source MAC address seen on a port witch has portsecurity enabled. The infoNewMacAddr is also reported in the newMacAddress trap.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..12)  

infoPoeInputVoltage 1.3.6.1.4.1.266.20.1.19
The current PoE input voltage delivered from the power supply.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

infoPoeInputPower 1.3.6.1.4.1.266.20.1.20
The current PoE input power delivered from the power supply.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

infoAlarmStateM1 1.3.6.1.4.1.266.20.1.21
The current state of the industrial alarm output M1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), alarmOff(2), alarmOn(3), alarmOnLinkDown(4), alarmOnForced(5), alarmOffForced(6), alarmOnPowerSupplyS1(7), alarmOnPowerSupplyS2(8), alarmOnPowerSupplyS1orS2(9), alarmOnFunctionInputShorted(10), alarmOnFunctionInputOpen(11), alarmOnRemoteFunctionInput(12), alarmOnRemoteAlarmDestTable(13), alarmOnLocalAlarmDestTable(14), alarmContactForcedShorted(15), alarmContactForcedOpen(16)  

infoAlarmStateM2 1.3.6.1.4.1.266.20.1.22
The current state of the industrial alarm output M2.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), alarmOff(2), alarmOn(3), alarmOnLinkDown(4), alarmOnForced(5), alarmOffForced(6), alarmOnPowerSupplyS1(7), alarmOnPowerSupplyS2(8), alarmOnPowerSupplyS1orS2(9), alarmOnFunctionInputShorted(10), alarmOnFunctionInputOpen(11), alarmOnRemoteFunctionInput(12), alarmOnRemoteAlarmDestTable(13), alarmOnLocalAlarmDestTable(14), alarmContactForcedShorted(15), alarmContactForcedOpen(16)  

infoLastTftpMessage 1.3.6.1.4.1.266.20.1.23
The message of the last successful or failed TFTP transfer. This does not include TFTP transfers executed from Device Manager.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString Size(0..80)  

infoLastSfpEventMessage 1.3.6.1.4.1.266.20.1.24
The last event message from one of the available SFP modules.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString Size(0..80)  

infoLastInternalMgmtWarning 1.3.6.1.4.1.266.20.1.25
The last internal management warning message.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString Size(0..80)  

infoFunctionInputStateF1 1.3.6.1.4.1.266.20.1.26
The current state of the function input F1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), functionInputShorted(2), functionInputOpen(3)  

infoTotalConfigChanges 1.3.6.1.4.1.266.20.1.27
The number of total configurations changes.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

adminReset 1.3.6.1.4.1.266.20.2.1
Writing this object causes the switch to perform a reset operation. The following reset types are supported. Set Values: resetCounters(2) This action resets all error and statistic counters to zero. This actions will NOT reboot the switch. rebootSwitch(3) This action resets switch and management. All counters, timers and other volatile data are reset to there power-up values stored in flash. This actions will reboot the switch. rebootToFactoryDefaults(4) This action resets switch and management. All volatile and nonvolatile data are reset to there power-up or factory default values. This actions will reboot the switch. renewIpAndVlanParameter(5) This action reinitializes the IP and VLAN module of the switch so that the actually set IP and VLAN parameters will take affect. This actions will NOT reboot the switch. Get values: resetIdle(1) Reading this object will allways return resetIdle(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER resetIdle(1), resetCounters(2), rebootSwitch(3), rebootToFactoryDefaults(4), renewIpAndVlanParameter(5)  

adminAgentDhcp 1.3.6.1.4.1.266.20.2.2
If set to enable(1), the switch tries to get his IP parameter via DHCP. If set to disable(2), the switch uses the IP parameters defined with adminIpAddress, adminDefRouterIpAddress and adminNetmask. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

adminAgentIpAddress 1.3.6.1.4.1.266.20.2.3
The IP address of the switch agent's ethernet interface. If the value of adminDHCP is enable(1) this value is read-only. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

adminAgentPhysAddress 1.3.6.1.4.1.266.20.2.4
The Ethernet MAC address of the switch agent.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

adminAgentDefRouterIpAddress 1.3.6.1.4.1.266.20.2.5
The IP address of the default Router. If the value of adminDHCP is enable(1) this value is read-only. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

adminAgentNetmask 1.3.6.1.4.1.266.20.2.6
The IP Netmask of the connected network. If the value of adminDHCP is enable(1) this value is read-only. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

adminAgentDhcpServerIpAddress 1.3.6.1.4.1.266.20.2.7
The IP address of the last used DHCP server.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

adminAgentVlanId 1.3.6.1.4.1.266.20.2.8
The VLAN-ID assigned to the agent. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4095  

adminAgentPrioValue 1.3.6.1.4.1.266.20.2.9
The IEEE802.1Q priority value and queue assigned to all frames transmitted by the agent. The definition between value, service class and queue are as follows: 0=Best Effort (queue=0), 1=Background (queue=0), 2=Reserved (queue=1), 3=Excellent Effort (queue=1), 4=Controlled Load (queue=2), 5=Video (queue=2), 6=Voice (queue=3), 7=Network Control (queue=3)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..7  

adminAddrAgingTimeMinutes 1.3.6.1.4.1.266.20.2.10
The timeout period in minutes for aging out dynamically learned MAC addresses . The allowed range is 1 minute to 68 minutes.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..68  

adminSwitchPortMirror 1.3.6.1.4.1.266.20.2.11
If set to enable(1), the switch doesn't use address learning. This affects that any received packet will be forwarded to all ports of the particular VLAN. The switch acts like a hub within each VLAN.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

adminMgmtAccessList 1.3.6.1.4.1.266.20.2.12
If set to enableForNexManAccess(2) or enableForAllAccess(3), the switch only accepts read or write requests from IP addresses which are listed in the management accesslist.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enableForNexManAccess(2), enableForAllAccess(3), enableForSnmpAccess(4)  

adminSwitchPoEPowerLimit 1.3.6.1.4.1.266.20.2.13
The limit for the POE input power from the power supply in VA. If the current power exceeds this value a overload conditions occurs and the inline power for the highest port number will be switched off.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

adminSwitchVlanTableMode 1.3.6.1.4.1.266.20.2.14
If set to staticMode(1) or staticModeVlans64(3) any existing VLAN table entry must be removed manually by management. With staticMode(1) total 16 VLAN-ID's and with staticModeVlans64(3) total 64 VLAN-ID's are supported. If set to dynamicMode(2) all unused VLAN-ID's are removed automatically by the switch. This means, that all VLAN-ID's not assigned to a port Default-VLAND or to the Unsecure-VLAN will be removed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER staticMode(1), dynamicMode(2), staticModeVlans64(3), staticModePortBased(4)  

adminUnsecureVlanId 1.3.6.1.4.1.266.20.2.15
The VLAN-ID of the unsecure VLAN
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4095  

adminDot1xAuthFailureVlanId 1.3.6.1.4.1.266.20.2.16
The VLAN-ID in the case of an IEEE802.1X authentication failure. Setting the VLAN-ID to 0 disables the authentication failure VLAN.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..4095  

adminTftpAccess 1.3.6.1.4.1.266.20.2.17
If 'TFTP authentication via SNMP' is disabled, this value is allways tftpAccessDisable(1). If 'TFTP authentication via SNMP' is read/only or read/write, an this object is read, the value is tftpAccessReadOnly(2) and the agent allowes a single TFTP read access of the switch configuration. If 'TFTP authentication via SNMP' is read/write, this value can be set to tftpAccessReadWrite(3) and the agent allowes a single TFTP read or write access to the configuration or a single firmware upgrade. After finishing the TFTP transfer, this value will return to ftpAccessDisable(1) automatically. Note: If the 'NexMan authentication mode' is set to 'none', TFTP read and write access is allways allowed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tftpAccessDisable(1), tftpAccessReadOnly(2), tftpAccessReadWrite(3)  

adminSnmpMacTableMode 1.3.6.1.4.1.266.20.2.18
If set to listAllPorts(1) the BRIDGE-MIBs dot1dTpFdbTable lits MAC address of all ports. If set to listUserPortsOnly(2) the BRIDGE-MIBs dot1dTpFdbTable lits only MAC addresses of user ports. MAC addresses of uplink/downlink ports are ignored.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER listAllPorts(1), listUserPortsOnly(2)  

adminAlarmM1 1.3.6.1.4.1.266.20.2.19
The current setup of the industrial alarm output M1.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), alarmLinkDown(2), alarmOnForced(3), alarmOffForced(4), alarmPowerSupply1Failure(5), alarmPowerSupply2Failure(6), alarmPowerSupply1or2Failure(7), alarmLocalFunctionInputShorted(8), alarmLocalFunctionInputOpen(9), alarmRemoteFunctionInput(10), alarmRemoteAlarmDestination(11), alarmLocalAlarmDestination(12), alarmForceContactShorted(13), alarmForceContactOpen(14), alarmForceContactOpenShorted(15)  

adminAlarmM2 1.3.6.1.4.1.266.20.2.20
The current setup of the industrial alarm output M2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), alarmLinkDown(2), alarmOnForced(3), alarmOffForced(4), alarmPowerSupply1Failure(5), alarmPowerSupply2Failure(6), alarmPowerSupply1or2Failure(7), alarmLocalFunctionInputShorted(8), alarmLocalFunctionInputOpen(9), alarmRemoteFunctionInput(10), alarmRemoteAlarmDestination(11), alarmLocalAlarmDestination(12), alarmForceContactShorted(13), alarmForceContactOpen(14), alarmForceContactOpenShorted(15)  

adminMemoryCardMode 1.3.6.1.4.1.266.20.2.21
If set to mcDisabled(2), the memory card is disabled but may be re-enabled later by writing mcEnabled(1). If set to mcPermanentDisabled(3), the memory card is disabled permanently and can't be re-enabled by management or any kind of hardware reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), mcEnabled(2), mcDisabled(3), mcPermanentDisabled(4)  

adminAlarmNameM1 1.3.6.1.4.1.266.20.2.22
An administratively assigned name for alarm output M1. The configured name will be send as part of alarm message switchIndustrialAlarmM1.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

adminAlarmNameM2 1.3.6.1.4.1.266.20.2.23
An administratively assigned name for alarm output M1. The configured name will be send as part of alarm message switchIndustrialAlarmM2.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

adminFunctionInputNameF1 1.3.6.1.4.1.266.20.2.24
An administratively assigned name for function input F1. The configured name will be send as part of alarm message switchFunctionInputAlarm.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

adminLedGlobalMode 1.3.6.1.4.1.266.20.2.25
Set the global mode for all front side LEDs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ledGlobalModeNotSupported(1), ledGlobalModeStandard(2), ledGlobalModeAllOff(3), ledGlobalModeAllOn(4), ledGlobalModeMgmtOnly(5)  

bmSwitchPortTable 1.3.6.1.4.1.266.20.3.1
A list of port entries for the switch. The number of entries is defined by ifNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortEntry

bmSwitchPortEntry 1.3.6.1.4.1.266.20.3.1.1
A port entry in the table containing information about a port in the switch.
Status: current Access: not-accessible
OBJECT-TYPE    
  PortEntry  

portIndex 1.3.6.1.4.1.266.20.3.1.1.1
A unique value for each port. Its value ranges between 1 and the value of ifNumber. The port identified by a particular value of this index is the same port as identified by the same value of ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..64  

portDescr 1.3.6.1.4.1.266.20.3.1.1.2
A textual string containing information about the interface. Same as ifDescr.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

portName 1.3.6.1.4.1.266.20.3.1.1.3
An administratively assigned name for this port.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

portAdminState 1.3.6.1.4.1.266.20.3.1.1.4
A value indicating the current state of the port. A SET to this object enables (2) or disables (3) the port. The possible values returned by GET are: allwaysEnable(1) The port is always enabled (usually the uplink port). enable(2) The port is active to transmit or receive data. disable(3) The port is inactive and unable to transmit or receive data. securityDisable(4) The port has been automatically disabled because of security violation. loopDisable(5) The port has been automatically disabled because of the active loop protection. bpduDisable(6) The port has been automatically disabled because a BPDU has been received on a Spanning Tree disabled port. udldDisable(7) The port has been automatically disabled because of the UDLD function. linkFlapDisable(8) The port has been automatically disabled because of the link flap protection. errorCountDisable(9) The port has been automatically disabled because of the error counter incrementation detection. sfpErrorDisable(10) The port has been automatically disabled because of wromg SFP inserted or SFP malfunction. redundanyLoopDisable(11) The port has been automatically disabled because of loop detection while spannung tree was enabled
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER allwaysEnable(1), enable(2), adminDisable(3), securityDisable(4), loopDisable(5), bpduDisable(6), udldDisable(7), linkFlapDisable(8), errorCountDisable(9), sfpErrorDisable(10), redundanyLoopDisable(11)  

portSpeedDuplexSetup 1.3.6.1.4.1.266.20.3.1.1.5
A value indicating the current speed and duplex link setup. Independent of portSpeedDuplexSetup the port may be disabled by portAdminState.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER autoneg(1), fix10Hdx(2), fix10Fdx(3), fix100Hdx(4), fix100Fdx(5), fix1000Hdx(7), fix1000Fdx(8), eco(9), ecoOverTemp(10), ecoPowerSave(11), fix1000fdxNoAutoneg(12)  

portLinkState 1.3.6.1.4.1.266.20.3.1.1.6
A value indicating the current link state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up10Hdx(2), up10Fdx(3), up100Hdx(4), up100Fdx(5), up1000Hdx(6), up1000Fdx(7)  

portErrorCounter 1.3.6.1.4.1.266.20.3.1.1.7
Errors are usually caused by a FDX/HDX mismatch between the switch port and the connected port. If the switch detects a incrementation of this counter, he will send a portErrorCountFailure trap. The counted errors are depending on the switch type. For BM-A, BM+ and Access Switches: - Received packets with bad CRC, - Received packets with bad alignment, - Late collisions (only valid if Link State is 10HDX or 100HDX). For old BM Switches: - Received packets with bad CRC
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portRemoteFault 1.3.6.1.4.1.266.20.3.1.1.8
If portRemoteFault is enabled for this port, the port transmitter will be only enabled if the port receiver has a valid link (portLinkState must not be down).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), enable(2), disable(3)  

portDefaultVlanId 1.3.6.1.4.1.266.20.3.1.1.9
The Default-VLAN-ID assigned to this port. This Default-VLAN-ID has differnt affects depending on received or transmited frames: a) All received frames, which have no VLAN-tag, will be assigned to the Default-VLAN-ID. b) All transmited frames, which belong to the Default-VLAN, are send without a VLAN-tag. If portTrunkingMode is set to dot1qTagging, all frames are transmited with a VLAN-tag, except frames which belong to the Default-VLAN-ID. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5). Setting this value to 0 for a port with dot1qTagging will disable the Default-VLAN. This means, that all frames are send tagged.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..4095  

portTrunkingMode 1.3.6.1.4.1.266.20.3.1.1.10
If portTrunkingMode is set to dot1qTagging, all frames are transmited with a VLAN-tag, except frames which belong to portNativeVlanId. If portTrunkingMode is set to enableWithoutTagging, all frames are transmited without a VLAN-tag. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dot1qTagging(1), disable(2), enableWithoutTagging(3)  

portDot1qDefaultPrioValue 1.3.6.1.4.1.266.20.3.1.1.11
The default IEEE802.1Q priority and queue assigned all frames received on this port, for which no other priorisation applies (IEEE801.1q Tag or IPv4/IPv6). The definition between value, service class and queue are as follows: 0=Best Effort (queue=0), 1=Background (queue=0), 2=Reserved (queue=1), 3=Excellent Effort (queue=1), 4=Controlled Load (queue=2), 5=Video (queue=2), 6=Voice (queue=3), 7=Network Control (queue=3)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..7  

portDefaultPrioQueue 1.3.6.1.4.1.266.20.3.1.1.12
The default priority queue assigned all frames received on this port, for which no other priorisation applies (IEEE801.1q Tag or IPv4/IPv6). A value of 0 means the lowest priority level. A value of 3 means the highest priority level. To change this default queue use object portDot1qDefaultPrioValue.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3  

portLEDGreen 1.3.6.1.4.1.266.20.3.1.1.13
The function of the green port LED. Only supported for user ports
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), showLinkState(2), blink(3), allwaysOff(4), allwaysOn(5), showLinkSpeedDuplex(6)  

portLEDYellow 1.3.6.1.4.1.266.20.3.1.1.14
The function of the yellow port LED. Only supported for user ports
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), showDuplexState(2), blink(3), allwaysOff(4), allwaysOn(5), showPoeEnabled(6), showSpeed(7)  

portBandwidthLimitRxd 1.3.6.1.4.1.266.20.3.1.1.15
The bandwidth limiter for received packets. If set to disable(2) the limiter will be disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), disable(2), limit128k(3), limit256k(4), limit512k(5), limit1M(6), limit2M(7), limit4M(8), limit8M(9), limit16M(10), limit32M(11), limit64M(12), limit128M(13), limit256M(14)  

portBandwidthLimitTxd 1.3.6.1.4.1.266.20.3.1.1.16
The bandwidth limiter for transmitted packets. If set to disable(2) the limiter will be disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), disable(2), limit128k(3), limit256k(4), limit512k(5), limit1M(6), limit2M(7), limit4M(8), limit8M(9), limit16M(10), limit32M(11), limit64M(12), limit128M(13), limit256M(14)  

portSecurityAdminState 1.3.6.1.4.1.266.20.3.1.1.17
Enables the port security feature for that port. A value of notSupported(1) means, that port security ist not supported or disabled for that port (i.e. uplink port). The command renew(10) clears all learned MAC addresses and enables the port if it is disabled. See documentation for more details.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), disable(2), manualSettingMacAddr(3), autoAllowOneMacAddr(4), autoAllowTwoMacAddr(5), autoAllowThreeMacAddr(6), radiusAllowOneMacAddr(7), radiusAllowTwoMacAddr(8), radiusAllowThreeMacAddr(9), renew(10), ieee802AllowOneMacAddr(11), vendorSettingMacAddr(12), ieee802AllowMultiMacAddr(13), ieee802OrRadiusOneMac(14), ieee802AndRadiusTwoMac(15), learnOneMacAddr(16), learnTwoMacAddr(17)  

portSecurityMacAddr1 1.3.6.1.4.1.266.20.3.1.1.18
The first MAC address used for port security. If portSecurityAdminState has the value disable(2), portSecurityManualSettingMacAddr(3) or vendorSettingMacAddr(12) then this object will be read-write. In any other mode this object will be read-only and shows the first automatically learned MAC addresses for that port.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

portSecurityMacAddr2 1.3.6.1.4.1.266.20.3.1.1.19
The second MAC address used for port security. If portSecurityAdminState has the value disable(2), portSecurityManualSettingMacAddr(3) or vendorSettingMacAddr(12) then this object will be read-write. In any other mode this object will be read-only and shows the second automatically learned MAC addresses for that port.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

portSecurityMacAddr3 1.3.6.1.4.1.266.20.3.1.1.20
The third MAC address used for port security. If portSecurityAdminState has the value disable(2), portSecurityManualSettingMacAddr(3) or vendorSettingMacAddr(12) then this object will be read-write. In any other mode this object will be read-only and shows the third automatically learned MAC addresses for that port.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

portPoeAdminState 1.3.6.1.4.1.266.20.3.1.1.21
If no POE adapter is installed this object is read-only and will always report notSupported(1). The possible values are: notSupported(1): No adapter installed or not supported for that port (i.e. uplink port). off(2): Adapter installed but inline power for that port is switched off. forcedOn(3): Adapter installed and inline power is asserted permanently. In the case of an IEEE802.3af adapter this setting will disable the IEEE802.3af automatic detection. autoOn(4): This setting is only supported if a IEEE802.3af adapter is installed. The adapter automatically detects if the connected device is IEEE802.3af compliant and will assert the power if possible. overloadFail(5): Adapter installed but inline power for that port is automatically switched off because of a overload condition at that port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), off(2), forcedOn(3), autoOn(4), overloadFail(5), reset(6), afHighPower(7), atHighPower(8)  

portPoeVoltage 1.3.6.1.4.1.266.20.3.1.1.22
The current PoE output voltage at this port in volts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

portPoeCurrent 1.3.6.1.4.1.266.20.3.1.1.23
The current PoE output current at this port in milliampere.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

portPoePower 1.3.6.1.4.1.266.20.3.1.1.24
The current PoE output power at this port in milliwatt. The output power is the product of portPoeVoltage and portPoeCurrent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

portSecurityForwardingState 1.3.6.1.4.1.266.20.3.1.1.25
The port security forwarding state of that port. See documentation for details.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), portAdminDisabled(2), waitingForLink(3), unsecureVLAN(4), portAuthenticated(5), portSecurityDisabled(6), portLoopDisabled(7), authFailureVLAN(8), securityWarning(9), authenticatingClients(10), waitingForMacAddress(11), allRadiusServersDown(12), portBpduDisabled(13), portUdldDisabled(14), portLinkFlapDisabled(15), portErrorCountDisabled(16), portSfpErrorDisabled(17), portRedundanyLoopDisable(18)  

portPoePowerLimit 1.3.6.1.4.1.266.20.3.1.1.26
The limit for the POE output power at this port in VA. If the current power exceeds this value a overload conditions occurs and the inline power for that port will be switched off.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

portLimiterPacketType 1.3.6.1.4.1.266.20.3.1.1.27
The packet type for bandwidth limiter. If set to limitAllPacktes(2) then all packets are limited. If set to limitLoppBcastPackets(3) only flooted loop- and broadcast-pakets are limited.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), limitAllPackets(2), limitLoopBcastPackets(3), limitAllPacketsBurstsAllowed(4)  

portAcApSetup 1.3.6.1.4.1.266.20.3.1.1.28
If portAcApSetup is enabled, the switch will perform Autocrossover and Autopolarity for this port. This function should only be enabled if portSpeedDuplexSetup ist set to autoneg.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), allwaysEnable(2), enable(3), disable(4)  

portLinkType 1.3.6.1.4.1.266.20.3.1.1.29
The link type of that port. If set to upDownlink(3) the portAdminState will be forced to enable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER user(1), userWithLoopProtection(2), upDownlink(3)  

portVoiceVlanId 1.3.6.1.4.1.266.20.3.1.1.30
The Voide-VLAN-ID assigned to this port. Packets of this Voice-VLAN are allway send with a VLAN-Tag, because IP-Phones normaly need a tagged VLAN. If portTrunkingMode is set to dot1qTagging, ALL frames are transmited with a VLAN-tag, except frames which belong to the Default-VLAN-ID. In this case the Voice-VLAN-ID has no effect. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5). Setting this value to 0 will disable the Voice-VLAN.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..4095  

portPrioDot1p 1.3.6.1.4.1.266.20.3.1.1.31
Defines whether port prioritisation for IEEE802.1p packets is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER prioDot1pDisabled(1), prioDot1pEnabled(2)  

portPrioIp 1.3.6.1.4.1.266.20.3.1.1.32
Defines whether port prioritisation for IPv4/IPv6 packets is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER prioIpDisabled(1), prioIpEnabled(2)  

bmSwitchVlanTable 1.3.6.1.4.1.266.20.4.1
A list of Virtual LAN instances.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VlanEntry

bmSwitchVlanEntry 1.3.6.1.4.1.266.20.4.1.1
VLAN entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  VlanEntry  

vlanIndex 1.3.6.1.4.1.266.20.4.1.1.1
A unique value for each VLAN entry. Its value ranges between 1 and 16.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..16  

vlanId 1.3.6.1.4.1.266.20.4.1.1.2
The VLAN-ID assigned to this entry. Only entries with a VLAN-ID greater then 0 are valid entries. Setting a valid VLAN-ID to 0 will disable that entry and also delete the vlanDescr To add a new VLAN-ID first set an valid or non valid entry to the desired VLAN-ID. In a second step you may set the vlanDescr. Only VLAN-ID's listed in the vlanTable are forwarded by the switch.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..4095  

vlanDescr 1.3.6.1.4.1.266.20.4.1.1.3
A textual string containing information about the VLAN.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..50)  

bmSwitchSfpTable 1.3.6.1.4.1.266.20.5.1
A list of SFP entries for the switch. The number of entries is defined by ifNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SfpEntry

bmSwitchSfpEntry 1.3.6.1.4.1.266.20.5.1.1
A SFP entry in the table containing information about a SFP in the switch.
Status: current Access: not-accessible
OBJECT-TYPE    
  SfpEntry  

sfpPortIndex 1.3.6.1.4.1.266.20.5.1.1.1
A unique value for each port. Its value ranges between 1 and the value of ifNumber. The port identified by a particular value of this index is the same port as identified by the same value of ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..64  

sfpState 1.3.6.1.4.1.266.20.5.1.1.2
A value indicating the current state of the SFP module. The possible values returned are: notSupported(1) The port has no SFP slot. noSfpInserted(2) The port has a SFP slot but there is no valid SFP module inserted. validSfpNoDiagnostic(3) A valid SFP module is inserted but the module doesn't supports diagnostic values. validSfpWithDiagnostic(4) A valid SFP module which supports diagnostic is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), noSfpInserted(2), validSfpNoDiagnostic(3), validSfpWithDiagnostic(4)  

sfpInfoVendorName 1.3.6.1.4.1.266.20.5.1.1.3
A textual string containing the vendor name of the SFP module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpInfoPartNumber 1.3.6.1.4.1.266.20.5.1.1.4
A textual string containing the part number of the SFP module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpInfoRevisionNumber 1.3.6.1.4.1.266.20.5.1.1.5
A textual string containing the revision number of the SFP module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpInfoSerialNumber 1.3.6.1.4.1.266.20.5.1.1.6
A textual string containing the serial number of the SFP module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpInfoDateCode 1.3.6.1.4.1.266.20.5.1.1.7
A textual string containing the date code of the SFP module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpInfoBitRate 1.3.6.1.4.1.266.20.5.1.1.8
A textual string containing the bit rate of the SFP module. The unit is Mbit/s
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpInfoWavelength 1.3.6.1.4.1.266.20.5.1.1.9
A textual string containing the wavelength of the SFP module. The unit is nm.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpInfoLength9um 1.3.6.1.4.1.266.20.5.1.1.10
A textual string containing the typically supported fiber length for 9um fiber cable. The unit is meters.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpInfoLength50um 1.3.6.1.4.1.266.20.5.1.1.11
A textual string containing the typically supported fiber length for 50um fiber cable. The unit is meters.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpInfoLength62um 1.3.6.1.4.1.266.20.5.1.1.12
A textual string containing the typically supported fiber length for 62.5um fiber cable. The unit is meters.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpInfoConnectorDescr 1.3.6.1.4.1.266.20.5.1.1.13
A textual string containing the connector description of the SFP module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

sfpDiagTemperature 1.3.6.1.4.1.266.20.5.1.1.14
The current temperature of the SFP module in degree celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sfpDiagSupplyVoltage 1.3.6.1.4.1.266.20.5.1.1.15
The current supply voltage of the SFP module in millivolt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sfpDiagTxBiasCurrent 1.3.6.1.4.1.266.20.5.1.1.16
The current transmitter bias current of the SFP module in milliampere.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sfpDiagTxOutputPower 1.3.6.1.4.1.266.20.5.1.1.17
The current transmitter output power of the SFP module in microwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sfpDiagTxOutputPowerDbm 1.3.6.1.4.1.266.20.5.1.1.18
The current transmitter output power of the SFP module in dbm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sfpDiagRxIntputPower 1.3.6.1.4.1.266.20.5.1.1.19
The current receiver input power of the SFP module in microwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sfpDiagRxInputPowerDbm 1.3.6.1.4.1.266.20.5.1.1.20
The current receiver input power of the SFP module in dbm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sfpAlarmTxBiasCurrentUpperLimit 1.3.6.1.4.1.266.20.5.1.1.21
The maximum allowed transmitter bias current in milliampere. If the current value indicated by sfpDiagTxBiasCurrent exceeds sfpAlarmTxBiasCurrentUpperLimit, the switch sends an sfpEvent alarm trap. If the value of this limit is 0 no alarm will be send.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sfpAlarmTxOutputPowerLowerLimit 1.3.6.1.4.1.266.20.5.1.1.22
The minimum required transmitter output power in microwatt. If the power value indicated by sfpDiagTxOutputPower falls below sfpAlarmTxOutputPowerLowerLimit, the switch sends an sfpEvent alarm trap. If the value of this limit is 0 no alarm will be send.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sfpAlarmRxInputPowerLowerLimit 1.3.6.1.4.1.266.20.5.1.1.23
The minimum required received input power in microwatt. If the power value indicated by sfpDiagRxInputPower falls below sfpAlarmRxInputPowerLowerLimit, the switch sends an sfpEvent alarm trap. If the value of this limit is 0 no alarm will be send.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

switchTemperatureFailure 1.3.6.1.4.1.266.20.0.1
A TemperatureFailure signifies that the switch hardware has detected under- or overtemperature condition.
Status: current Access: read-write
NOTIFICATION-TYPE    

portLinkChange 1.3.6.1.4.1.266.20.0.2
The trap is sent whenever the link state of a port changes from link-up to link-down or from link-down to link-up
Status: current Access: read-write
NOTIFICATION-TYPE    

portNewMacAddress 1.3.6.1.4.1.266.20.0.3
A new source MAC address has been detected on a switch port. This trap is only send for ports which have port-security enabled with the setting autoAllowOneMacAddr, autoAllowTwoMacAddr or autoAllowThreeMacAddr.
Status: current Access: read-write
NOTIFICATION-TYPE    

portSecurityFailure 1.3.6.1.4.1.266.20.0.4
An unauthorized source MAC address has accessed a port which has port-security enabled.
Status: current Access: read-write
NOTIFICATION-TYPE    

portErrorCountFailure 1.3.6.1.4.1.266.20.0.5
The port error counter has incremented by 2 or more within a timewindow of two seconds. An counter increment by 1 ist not reported because single increments often may result because of link-changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

switchMgmtAuthFailure 1.3.6.1.4.1.266.20.0.6
A station has tried to access the switch management with a wrong authentication. This includes wrong user/password for telnet, wrong community for SNMP read/write and wrong accessrights in the accesslist.
Status: current Access: read-write
NOTIFICATION-TYPE    

radiusMgmtAuthReject 1.3.6.1.4.1.266.20.0.7
A station has tried to access the switch management with radius authentication enabled and the radius server has rejected the request.
Status: current Access: read-write
NOTIFICATION-TYPE    

radiusPortSecurityReject 1.3.6.1.4.1.266.20.0.8
A station has tried to access the switch with radius port security authentication enabled and the radius server has rejected the request.
Status: current Access: read-write
NOTIFICATION-TYPE    

portLoopBcastFailure 1.3.6.1.4.1.266.20.0.9
The port broadcast/multicast counter has incremented by 25 packets/second for more then 10 successive seconds. Excessive multicast or broadcast packets may result in case of a loop between two port of the switch.
Status: current Access: read-write
NOTIFICATION-TYPE    

switchPoeVoltageFailure 1.3.6.1.4.1.266.20.0.10
The switch has detected a PoE over- or undervoltage conditions.
Status: current Access: read-write
NOTIFICATION-TYPE    

switchPoeOverloadFailure 1.3.6.1.4.1.266.20.0.11
The switch has detected a overload for the PoE power supply.
Status: current Access: read-write
NOTIFICATION-TYPE    

portPoeOverloadFailure 1.3.6.1.4.1.266.20.0.12
The switch has detected a PoE overload condition at the port.
Status: current Access: read-write
NOTIFICATION-TYPE    

portActiveLoopDetectionFailure 1.3.6.1.4.1.266.20.0.13
The active loop protection has disabled the port.
Status: current Access: read-write
NOTIFICATION-TYPE    

switchIndustrialAlarmM1 1.3.6.1.4.1.266.20.0.14
The alarm state of the industrial alarm output M1 has changed.
Status: current Access: read-write
NOTIFICATION-TYPE    

switchIndustrialAlarmM2 1.3.6.1.4.1.266.20.0.15
The alarm state of the industrial alarm output M2 has changed.
Status: current Access: read-write
NOTIFICATION-TYPE    

switchInternalVoltageFailure 1.3.6.1.4.1.266.20.0.16
The switch has detected a internal over- or undervoltage conditions.
Status: current Access: read-write
NOTIFICATION-TYPE    

tftpMessage 1.3.6.1.4.1.266.20.0.17
An successful or failed TFTP transfer has been occured. This does not include TFTP transfers executed from Nexan Manager.
Status: current Access: read-write
NOTIFICATION-TYPE    

sfpEvent 1.3.6.1.4.1.266.20.0.18
The switch has detected one of the following SFP events: - a SFP module has been inserted - a SFP module has been removed - the optical receive power has fallen below the configured threshold - the optical transmit power has fallen below the configured threshold - the laser bias current has exceeded the configured threshold In the case of a threshold event, the trap will only send out every five minutes.
Status: current Access: read-write
NOTIFICATION-TYPE    

clientRemoved 1.3.6.1.4.1.266.20.0.19
The client on this port has been removed because the link down time has exceeded the configured 'Link Down Timeout'.
Status: current Access: read-write
NOTIFICATION-TYPE    

internalMgmtWarning 1.3.6.1.4.1.266.20.0.20
An internal management warning has been detected. Please consult Nexans for further informations regarding the reported warning code.
Status: current Access: read-write
NOTIFICATION-TYPE    

switchFunctionInputAlarm 1.3.6.1.4.1.266.20.0.21
The state of the function input has changed.
Status: current Access: read-write
NOTIFICATION-TYPE    

switchConfigurationChanged 1.3.6.1.4.1.266.20.0.22
The configuration of the switch has been changed.
Status: current Access: read-write
NOTIFICATION-TYPE    

portErrorDisabled 1.3.6.1.4.1.266.20.0.23
The port has been error disabled.
Status: current Access: read-write
NOTIFICATION-TYPE