NETBOTZ320-MIB

File: NETBOTZ320-MIB.mib (236632 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
enterprises Counter32 Integer32
TEXTUAL-CONVENTION DisplayString DateAndTime

Defined Types

OperStatus  
The operational status of the device entity.
TEXTUAL-CONVENTION    
  INTEGER disconnected(0), error(1), normal(2)  

ErrorStatus  
The error status of the device entity. If there are no error conditions reported for the entity, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the entity.
TEXTUAL-CONVENTION    
  INTEGER normal(0), info(1), warning(2), error(3), critical(4), failure(5)  

BoolValue  
A boolean value.
TEXTUAL-CONVENTION    
  INTEGER no(0), yes(1), null(2)  

EnclosureEntry  
SEQUENCE    
  enclosureId DisplayString
  enclosureStatus OperStatus
  enclosureErrorStatus ErrorStatus
  enclosureLabel DisplayString
  enclosureParentEncId DisplayString
  enclosureDockedToEncId DisplayString
  enclosureIndex Counter32

DINPortEntry  
SEQUENCE    
  dinPortId DisplayString
  dinPortStatus OperStatus
  dinPortLabel DisplayString
  dinPortEncId DisplayString
  dinPortSensorIdSuffix DisplayString
  dinPortSupportsAverage BoolValue
  dinPortSupportsRMS BoolValue
  dinPortSupportsDryContact BoolValue
  dinPortIndex Counter32

OtherPortEntry  
SEQUENCE    
  otherPortId DisplayString
  otherPortStatus OperStatus
  otherPortLabel DisplayString
  otherPortEncId DisplayString
  otherPortIndex Counter32

TempSensorEntry  
SEQUENCE    
  tempSensorId DisplayString
  tempSensorValue Integer32
  tempSensorErrorStatus ErrorStatus
  tempSensorLabel DisplayString
  tempSensorEncId DisplayString
  tempSensorPortId DisplayString
  tempSensorValueStr DisplayString
  tempSensorValueInt Integer32
  tempSensorValueIntF Integer32
  tempSensorIndex Counter32

HumiSensorEntry  
SEQUENCE    
  humiSensorId DisplayString
  humiSensorValue Integer32
  humiSensorErrorStatus ErrorStatus
  humiSensorLabel DisplayString
  humiSensorEncId DisplayString
  humiSensorPortId DisplayString
  humiSensorValueStr DisplayString
  humiSensorValueInt Integer32
  humiSensorIndex Counter32

DewPointSensorEntry  
SEQUENCE    
  dewPointSensorId DisplayString
  dewPointSensorValue Integer32
  dewPointSensorErrorStatus ErrorStatus
  dewPointSensorLabel DisplayString
  dewPointSensorEncId DisplayString
  dewPointSensorPortId DisplayString
  dewPointSensorValueStr DisplayString
  dewPointSensorValueInt Integer32
  dewPointSensorValueIntF Integer32
  dewPointSensorIndex Counter32

AudioSensorEntry  
SEQUENCE    
  audioSensorId DisplayString
  audioSensorValue Integer32
  audioSensorErrorStatus ErrorStatus
  audioSensorLabel DisplayString
  audioSensorEncId DisplayString
  audioSensorPortId DisplayString
  audioSensorValueStr DisplayString
  audioSensorValueInt Integer32
  audioSensorIndex Counter32

AirFlowSensorEntry  
SEQUENCE    
  airFlowSensorId DisplayString
  airFlowSensorValue Integer32
  airFlowSensorErrorStatus ErrorStatus
  airFlowSensorLabel DisplayString
  airFlowSensorEncId DisplayString
  airFlowSensorPortId DisplayString
  airFlowSensorValueStr DisplayString
  airFlowSensorValueInt Integer32
  airFlowSensorIndex Counter32

AmpDetectSensorEntry  
SEQUENCE    
  ampDetectSensorId DisplayString
  ampDetectSensorValue Integer32
  ampDetectSensorErrorStatus ErrorStatus
  ampDetectSensorLabel DisplayString
  ampDetectSensorEncId DisplayString
  ampDetectSensorPortId DisplayString
  ampDetectSensorValueStr DisplayString
  ampDetectSensorValueInt Integer32
  ampDetectSensorIndex Counter32

OtherNumericSensorEntry  
SEQUENCE    
  otherNumericSensorId DisplayString
  otherNumericSensorValue Integer32
  otherNumericSensorErrorStatus ErrorStatus
  otherNumericSensorLabel DisplayString
  otherNumericSensorEncId DisplayString
  otherNumericSensorPortId DisplayString
  otherNumericSensorValueStr DisplayString
  otherNumericSensorValueInt Integer32
  otherNumericSensorUnits DisplayString
  otherNumericSensorValueIntX1000 Integer32
  otherNumericSensorValueIntX1000000 Integer32
  otherNumericSensorIndex Counter32

DryContactSensorEntry  
SEQUENCE    
  dryContactSensorId DisplayString
  dryContactSensorValue INTEGER
  dryContactSensorErrorStatus ErrorStatus
  dryContactSensorLabel DisplayString
  dryContactSensorEncId DisplayString
  dryContactSensorPortId DisplayString
  dryContactSensorValueStr DisplayString
  dryContactSensorIndex Counter32

DoorSwitchSensorEntry  
SEQUENCE    
  doorSwitchSensorId DisplayString
  doorSwitchSensorValue INTEGER
  doorSwitchSensorErrorStatus ErrorStatus
  doorSwitchSensorLabel DisplayString
  doorSwitchSensorEncId DisplayString
  doorSwitchSensorPortId DisplayString
  doorSwitchSensorValueStr DisplayString
  doorSwitchSensorIndex Counter32

CameraMotionSensorEntry  
SEQUENCE    
  cameraMotionSensorId DisplayString
  cameraMotionSensorValue INTEGER
  cameraMotionSensorErrorStatus ErrorStatus
  cameraMotionSensorLabel DisplayString
  cameraMotionSensorEncId DisplayString
  cameraMotionSensorPortId DisplayString
  cameraMotionSensorValueStr DisplayString
  cameraMotionSensorIndex Counter32

OtherStateSensorEntry  
SEQUENCE    
  otherStateSensorId DisplayString
  otherStateSensorValue INTEGER
  otherStateSensorErrorStatus ErrorStatus
  otherStateSensorLabel DisplayString
  otherStateSensorEncId DisplayString
  otherStateSensorPortId DisplayString
  otherStateSensorValueStr DisplayString
  otherStateSensorIndex Counter32

ErrorCondEntry  
SEQUENCE    
  errorCondId DisplayString
  errorCondSeverity ErrorStatus
  errorCondTypeId DisplayString
  errorCondStartTime DateAndTime
  errorCondStartTimeStr DisplayString
  errorCondResolved BoolValue
  errorCondResolvedTime DateAndTime
  errorCondResolvedTimeStr DisplayString
  errorCondEncId DisplayString
  errorCondPortId DisplayString
  errorCondSensorId DisplayString
  errorCondIndex Counter32

Defined Values

netBotz-APC 1.3.6.1.4.1.5528.100.1
NetBotz-APC BotzWare MIB
MODULE-IDENTITY    

netBotzAPC 1.3.6.1.4.1.5528
OBJECT IDENTIFIER    

netBotz 1.3.6.1.4.1.5528.100
OBJECT IDENTIFIER    

netBotzTraps 1.3.6.1.4.1.5528.100.10
OBJECT IDENTIFIER    

netBotzTrapParms 1.3.6.1.4.1.5528.100.11
OBJECT IDENTIFIER    

netBotzProducts 1.3.6.1.4.1.5528.100.20
OBJECT IDENTIFIER    

netBotzGenericTraps 1.3.6.1.4.1.5528.100.10.1
OBJECT IDENTIFIER    

netBotzSensorTraps 1.3.6.1.4.1.5528.100.10.2
OBJECT IDENTIFIER    

netBotzPodTraps 1.3.6.1.4.1.5528.100.10.3
OBJECT IDENTIFIER    

netBotzPortTraps 1.3.6.1.4.1.5528.100.10.4
OBJECT IDENTIFIER    

netBotzTempSensorTraps 1.3.6.1.4.1.5528.100.10.2.1
OBJECT IDENTIFIER    

netBotzHumiditySensorTraps 1.3.6.1.4.1.5528.100.10.2.2
OBJECT IDENTIFIER    

netBotzDewPointSensorTraps 1.3.6.1.4.1.5528.100.10.2.3
OBJECT IDENTIFIER    

netBotzAirFlowSensorTraps 1.3.6.1.4.1.5528.100.10.2.4
OBJECT IDENTIFIER    

netBotzAudioSensorTraps 1.3.6.1.4.1.5528.100.10.2.5
OBJECT IDENTIFIER    

netBotzAmpDetectSensorTraps 1.3.6.1.4.1.5528.100.10.2.6
OBJECT IDENTIFIER    

netBotzDryContactSensorTraps 1.3.6.1.4.1.5528.100.10.2.7
OBJECT IDENTIFIER    

netBotzCameraMotionSensorTraps 1.3.6.1.4.1.5528.100.10.2.8
OBJECT IDENTIFIER    

netBotzDoorSensorTraps 1.3.6.1.4.1.5528.100.10.2.9
OBJECT IDENTIFIER    

netBotzMicPlugSensorTraps 1.3.6.1.4.1.5528.100.10.2.10
OBJECT IDENTIFIER    

netBotzSpeakerPlugSensorTraps 1.3.6.1.4.1.5528.100.10.2.11
OBJECT IDENTIFIER    

netBotzTVSignalSensorTraps 1.3.6.1.4.1.5528.100.10.2.12
OBJECT IDENTIFIER    

netBotzGPSPositionSensorTraps 1.3.6.1.4.1.5528.100.10.2.13
OBJECT IDENTIFIER    

netBotzGPSMovementSensorTraps 1.3.6.1.4.1.5528.100.10.2.14
OBJECT IDENTIFIER    

netBotzGPSStatusSensorTraps 1.3.6.1.4.1.5528.100.10.2.15
OBJECT IDENTIFIER    

netBotzWirelessStatusSensorTraps 1.3.6.1.4.1.5528.100.10.2.22
OBJECT IDENTIFIER    

netBotzPacketDropSensorTraps 1.3.6.1.4.1.5528.100.10.2.23
OBJECT IDENTIFIER    

netBotzSNMPCrawlerSensorTraps 1.3.6.1.4.1.5528.100.10.2.24
OBJECT IDENTIFIER    

netBotzPlugModuleStatusSensorTraps 1.3.6.1.4.1.5528.100.10.2.25
OBJECT IDENTIFIER    

netBotzOutputControlSensorTraps 1.3.6.1.4.1.5528.100.10.2.26
OBJECT IDENTIFIER    

netBotzMultiRAESensorTraps 1.3.6.1.4.1.5528.100.10.2.27
OBJECT IDENTIFIER    

netBotzMultiRAESensorStatusTraps 1.3.6.1.4.1.5528.100.10.2.28
OBJECT IDENTIFIER    

netBotzMultiRAEDeviceStatusTraps 1.3.6.1.4.1.5528.100.10.2.29
OBJECT IDENTIFIER    

netBotzLinkStatusSensorTraps 1.3.6.1.4.1.5528.100.10.2.30
OBJECT IDENTIFIER    

netBotzLoopVoltageSensorTraps 1.3.6.1.4.1.5528.100.10.2.31
OBJECT IDENTIFIER    

netBotzBasePodTraps 1.3.6.1.4.1.5528.100.10.3.1
OBJECT IDENTIFIER    

netBotzSensorPodTraps 1.3.6.1.4.1.5528.100.10.3.2
OBJECT IDENTIFIER    

netBotzCameraPodTraps 1.3.6.1.4.1.5528.100.10.3.3
OBJECT IDENTIFIER    

netBotzCCTVPodTraps 1.3.6.1.4.1.5528.100.10.3.4
OBJECT IDENTIFIER    

netBotz4to20mAPodTraps 1.3.6.1.4.1.5528.100.10.3.5
OBJECT IDENTIFIER    

netBotzBotz 1.3.6.1.4.1.5528.100.20.10
OBJECT IDENTIFIER    

netBotzWallBotz500 1.3.6.1.4.1.5528.100.20.10.2000
OBJECT IDENTIFIER    

netBotz420Wall 1.3.6.1.4.1.5528.100.20.10.2001
OBJECT IDENTIFIER    

raeSystemsAreaConnect500 1.3.6.1.4.1.5528.100.20.10.2002
OBJECT IDENTIFIER    

netBotz420Rack 1.3.6.1.4.1.5528.100.20.10.2003
OBJECT IDENTIFIER    

netBotz320Wall 1.3.6.1.4.1.5528.100.20.10.2004
OBJECT IDENTIFIER    

netBotz320Rack 1.3.6.1.4.1.5528.100.20.10.2005
OBJECT IDENTIFIER    

netBotz420ERack 1.3.6.1.4.1.5528.100.20.10.2006
OBJECT IDENTIFIER    

netBotz320ERack 1.3.6.1.4.1.5528.100.20.10.2007
OBJECT IDENTIFIER    

netBotz220Camera 1.3.6.1.4.1.5528.100.20.10.2008
OBJECT IDENTIFIER    

apprion500 1.3.6.1.4.1.5528.100.20.10.2009
OBJECT IDENTIFIER    

avocent500 1.3.6.1.4.1.5528.100.20.10.2010
OBJECT IDENTIFIER    

netBotz320EWall 1.3.6.1.4.1.5528.100.20.10.2011
OBJECT IDENTIFIER    

netBotz420EWall 1.3.6.1.4.1.5528.100.20.10.2012
OBJECT IDENTIFIER    

netBotz550Rack 1.3.6.1.4.1.5528.100.20.10.2013
OBJECT IDENTIFIER    

netBotz450Rack 1.3.6.1.4.1.5528.100.20.10.2014
OBJECT IDENTIFIER    

netBotz455Wall 1.3.6.1.4.1.5528.100.20.10.2015
OBJECT IDENTIFIER    

netBotz355Wall 1.3.6.1.4.1.5528.100.20.10.2016
OBJECT IDENTIFIER    

netBotzEnclosures 1.3.6.1.4.1.5528.100.2
OBJECT IDENTIFIER    

netBotzPorts 1.3.6.1.4.1.5528.100.3
OBJECT IDENTIFIER    

netBotzSensors 1.3.6.1.4.1.5528.100.4
OBJECT IDENTIFIER    

netBotzErrors 1.3.6.1.4.1.5528.100.5
OBJECT IDENTIFIER    

netBotzNumericSensors 1.3.6.1.4.1.5528.100.4.1
OBJECT IDENTIFIER    

netBotzStateSensors 1.3.6.1.4.1.5528.100.4.2
OBJECT IDENTIFIER    

netBotzErrorStatus 1.3.6.1.4.1.5528.100.100
The error status of the appliance. If there are no error conditions reported for the appliance, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the appliance.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

enclosureTable 1.3.6.1.4.1.5528.100.2.1
A list of enclosures (base enclosure and pods).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EnclosureEntry

enclosureEntry 1.3.6.1.4.1.5528.100.2.1.1
Enclosure entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  EnclosureEntry  

enclosureId 1.3.6.1.4.1.5528.100.2.1.1.1
The id of the physical enclosure.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

enclosureStatus 1.3.6.1.4.1.5528.100.2.1.1.2
The operational status of the enclosure.
Status: current Access: read-only
OBJECT-TYPE    
  OperStatus  

enclosureErrorStatus 1.3.6.1.4.1.5528.100.2.1.1.3
The error status of the enclosure. If there are no error conditions reported for the enclosure, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the enclosure.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

enclosureLabel 1.3.6.1.4.1.5528.100.2.1.1.4
The unique label assigned to the enclosure (or pod).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

enclosureParentEncId 1.3.6.1.4.1.5528.100.2.1.1.5
The id of the parent enclosure this enclosure is attached to.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

enclosureDockedToEncId 1.3.6.1.4.1.5528.100.2.1.1.6
The id of the enclosure this enclosure is hard-docked with, i.e. as when sensor and camera pods are docked with the base system unit.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

enclosureIndex 1.3.6.1.4.1.5528.100.2.1.1.7
The index of the physical enclosure.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dinPortTable 1.3.6.1.4.1.5528.100.3.1
A list of DIN port entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DINPortEntry

dinPortEntry 1.3.6.1.4.1.5528.100.3.1.1
DIN port entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  DINPortEntry  

dinPortId 1.3.6.1.4.1.5528.100.3.1.1.1
The unique id of the port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

dinPortStatus 1.3.6.1.4.1.5528.100.3.1.1.2
The operational status of the port.
Status: current Access: read-only
OBJECT-TYPE    
  OperStatus  

dinPortLabel 1.3.6.1.4.1.5528.100.3.1.1.3
The unique label assigned to the port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dinPortEncId 1.3.6.1.4.1.5528.100.3.1.1.4
The id of the physical enclosure containing the port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

dinPortSensorIdSuffix 1.3.6.1.4.1.5528.100.3.1.1.5
The ID suffix added to a sensor plugged into the port. The ID suffix is combined with the sensor class ID when generating a local unique id for the DIN sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dinPortSupportsAverage 1.3.6.1.4.1.5528.100.3.1.1.6
Whether the port supports returning the average voltage reading of the sensor. This is used to determine which classes of sensors are supported by the port.
Status: current Access: read-only
OBJECT-TYPE    
  BoolValue  

dinPortSupportsRMS 1.3.6.1.4.1.5528.100.3.1.1.7
Whether the port supports returning the AC RMS voltage reading of the sensor. This is used to determine which classes of sensors are supported by the port.
Status: current Access: read-only
OBJECT-TYPE    
  BoolValue  

dinPortSupportsDryContact 1.3.6.1.4.1.5528.100.3.1.1.8
Whether the port supports generating the 'open' and 'closed' state of a dry contact sensor. This information is used to determine which classes of sensors are supported by the port.
Status: current Access: read-only
OBJECT-TYPE    
  BoolValue  

dinPortIndex 1.3.6.1.4.1.5528.100.3.1.1.9
The index of the port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

otherPortTable 1.3.6.1.4.1.5528.100.3.10
A list of other port entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OtherPortEntry

otherPortEntry 1.3.6.1.4.1.5528.100.3.10.1
Other port entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  OtherPortEntry  

otherPortId 1.3.6.1.4.1.5528.100.3.10.1.1
The unique id of the port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

otherPortStatus 1.3.6.1.4.1.5528.100.3.10.1.2
The operational status of the port.
Status: current Access: read-only
OBJECT-TYPE    
  OperStatus  

otherPortLabel 1.3.6.1.4.1.5528.100.3.10.1.3
The unique label assigned to the port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

otherPortEncId 1.3.6.1.4.1.5528.100.3.10.1.4
The id of the physical enclosure containing the port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

otherPortIndex 1.3.6.1.4.1.5528.100.3.10.1.5
The index of the port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

tempSensorTable 1.3.6.1.4.1.5528.100.4.1.1
A list of temperature sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TempSensorEntry

tempSensorEntry 1.3.6.1.4.1.5528.100.4.1.1.1
A temperature sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  TempSensorEntry  

tempSensorId 1.3.6.1.4.1.5528.100.4.1.1.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

tempSensorValue 1.3.6.1.4.1.5528.100.4.1.1.1.2
The temperature measured by the sensor in tenths of a degree Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -500..1000  

tempSensorErrorStatus 1.3.6.1.4.1.5528.100.4.1.1.1.3
The error status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

tempSensorLabel 1.3.6.1.4.1.5528.100.4.1.1.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tempSensorEncId 1.3.6.1.4.1.5528.100.4.1.1.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

tempSensorPortId 1.3.6.1.4.1.5528.100.4.1.1.1.6
The id of the port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

tempSensorValueStr 1.3.6.1.4.1.5528.100.4.1.1.1.7
The temperature reading, in degrees celsius, shown as a string (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tempSensorValueInt 1.3.6.1.4.1.5528.100.4.1.1.1.8
The temperature measured by the sensor in degree Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -50..100  

tempSensorValueIntF 1.3.6.1.4.1.5528.100.4.1.1.1.9
The temperature measured by the sensor in degree Farenheit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -50..212  

tempSensorIndex 1.3.6.1.4.1.5528.100.4.1.1.1.10
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

humiSensorTable 1.3.6.1.4.1.5528.100.4.1.2
A list of humidity sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HumiSensorEntry

humiSensorEntry 1.3.6.1.4.1.5528.100.4.1.2.1
A humidity sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  HumiSensorEntry  

humiSensorId 1.3.6.1.4.1.5528.100.4.1.2.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

humiSensorValue 1.3.6.1.4.1.5528.100.4.1.2.1.2
The relative humidity measured by the sensor in tenths of a percent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1000  

humiSensorErrorStatus 1.3.6.1.4.1.5528.100.4.1.2.1.3
The error status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

humiSensorLabel 1.3.6.1.4.1.5528.100.4.1.2.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

humiSensorEncId 1.3.6.1.4.1.5528.100.4.1.2.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

humiSensorPortId 1.3.6.1.4.1.5528.100.4.1.2.1.6
The id of the port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

humiSensorValueStr 1.3.6.1.4.1.5528.100.4.1.2.1.7
The humidity reading, in percent, shown as a string (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

humiSensorValueInt 1.3.6.1.4.1.5528.100.4.1.2.1.8
The relative humidity measured by the sensor in percent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..100  

humiSensorIndex 1.3.6.1.4.1.5528.100.4.1.2.1.9
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dewPointSensorTable 1.3.6.1.4.1.5528.100.4.1.3
A list of dew point sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DewPointSensorEntry

dewPointSensorEntry 1.3.6.1.4.1.5528.100.4.1.3.1
A dew point sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  DewPointSensorEntry  

dewPointSensorId 1.3.6.1.4.1.5528.100.4.1.3.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

dewPointSensorValue 1.3.6.1.4.1.5528.100.4.1.3.1.2
The dew point value measured by the sensor in tenths of a degree Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -500..1000  

dewPointSensorErrorStatus 1.3.6.1.4.1.5528.100.4.1.3.1.3
The operational status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

dewPointSensorLabel 1.3.6.1.4.1.5528.100.4.1.3.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dewPointSensorEncId 1.3.6.1.4.1.5528.100.4.1.3.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

dewPointSensorPortId 1.3.6.1.4.1.5528.100.4.1.3.1.6
The id of the port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

dewPointSensorValueStr 1.3.6.1.4.1.5528.100.4.1.3.1.7
The dew point reading, in degrees celsius, shown as a string (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dewPointSensorValueInt 1.3.6.1.4.1.5528.100.4.1.3.1.8
The dew point value measured by the sensor in degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -50..100  

dewPointSensorValueIntF 1.3.6.1.4.1.5528.100.4.1.3.1.9
The dew point reading in degrees Farenheit, measured by the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -40..122  

dewPointSensorIndex 1.3.6.1.4.1.5528.100.4.1.3.1.10
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

audioSensorTable 1.3.6.1.4.1.5528.100.4.1.4
A list of audio sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AudioSensorEntry

audioSensorEntry 1.3.6.1.4.1.5528.100.4.1.4.1
An audio sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  AudioSensorEntry  

audioSensorId 1.3.6.1.4.1.5528.100.4.1.4.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

audioSensorValue 1.3.6.1.4.1.5528.100.4.1.4.1.2
The (unitless) audio level measured by the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

audioSensorErrorStatus 1.3.6.1.4.1.5528.100.4.1.4.1.3
The error status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

audioSensorLabel 1.3.6.1.4.1.5528.100.4.1.4.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

audioSensorEncId 1.3.6.1.4.1.5528.100.4.1.4.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

audioSensorPortId 1.3.6.1.4.1.5528.100.4.1.4.1.6
The id of the port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

audioSensorValueStr 1.3.6.1.4.1.5528.100.4.1.4.1.7
The audio reading shown as a string (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

audioSensorValueInt 1.3.6.1.4.1.5528.100.4.1.4.1.8
The (unitless) audio level measured by the sensor (1/10 of audioSensorValue).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

audioSensorIndex 1.3.6.1.4.1.5528.100.4.1.4.1.9
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

airFlowSensorTable 1.3.6.1.4.1.5528.100.4.1.5
A list of airflow sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AirFlowSensorEntry

airFlowSensorEntry 1.3.6.1.4.1.5528.100.4.1.5.1
An air flow sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  AirFlowSensorEntry  

airFlowSensorId 1.3.6.1.4.1.5528.100.4.1.5.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

airFlowSensorValue 1.3.6.1.4.1.5528.100.4.1.5.1.2
The air flow measured by the sensor in tenths of a meter per minute.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..10000  

airFlowSensorErrorStatus 1.3.6.1.4.1.5528.100.4.1.5.1.3
The error status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

airFlowSensorLabel 1.3.6.1.4.1.5528.100.4.1.5.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

airFlowSensorEncId 1.3.6.1.4.1.5528.100.4.1.5.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

airFlowSensorPortId 1.3.6.1.4.1.5528.100.4.1.5.1.6
The id of the port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

airFlowSensorValueStr 1.3.6.1.4.1.5528.100.4.1.5.1.7
The airflow reading, in meters per minute, shown as a string (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

airFlowSensorValueInt 1.3.6.1.4.1.5528.100.4.1.5.1.8
The air flow measured by the sensor in meters per minute.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1000  

airFlowSensorIndex 1.3.6.1.4.1.5528.100.4.1.5.1.9
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ampDetectSensorTable 1.3.6.1.4.1.5528.100.4.1.6
A list of amp detect sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AmpDetectSensorEntry

ampDetectSensorEntry 1.3.6.1.4.1.5528.100.4.1.6.1
An ampere sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  AmpDetectSensorEntry  

ampDetectSensorId 1.3.6.1.4.1.5528.100.4.1.6.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

ampDetectSensorValue 1.3.6.1.4.1.5528.100.4.1.6.1.2
The value measured by the sensor in tenths of an ampere.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

ampDetectSensorErrorStatus 1.3.6.1.4.1.5528.100.4.1.6.1.3
The operational status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

ampDetectSensorLabel 1.3.6.1.4.1.5528.100.4.1.6.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ampDetectSensorEncId 1.3.6.1.4.1.5528.100.4.1.6.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

ampDetectSensorPortId 1.3.6.1.4.1.5528.100.4.1.6.1.6
The id of the port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

ampDetectSensorValueStr 1.3.6.1.4.1.5528.100.4.1.6.1.7
The amp detect reading, in amperes, shown as a string (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ampDetectSensorValueInt 1.3.6.1.4.1.5528.100.4.1.6.1.8
The value measured by the sensor in amperes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..6554  

ampDetectSensorIndex 1.3.6.1.4.1.5528.100.4.1.6.1.9
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

otherNumericSensorTable 1.3.6.1.4.1.5528.100.4.1.10
A list of other numeric sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OtherNumericSensorEntry

otherNumericSensorEntry 1.3.6.1.4.1.5528.100.4.1.10.1
Other numeric sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  OtherNumericSensorEntry  

otherNumericSensorId 1.3.6.1.4.1.5528.100.4.1.10.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

otherNumericSensorValue 1.3.6.1.4.1.5528.100.4.1.10.1.2
The value measured by the sensor in tenths of the unit of measure.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

otherNumericSensorErrorStatus 1.3.6.1.4.1.5528.100.4.1.10.1.3
The operational status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

otherNumericSensorLabel 1.3.6.1.4.1.5528.100.4.1.10.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

otherNumericSensorEncId 1.3.6.1.4.1.5528.100.4.1.10.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

otherNumericSensorPortId 1.3.6.1.4.1.5528.100.4.1.10.1.6
The id of the port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

otherNumericSensorValueStr 1.3.6.1.4.1.5528.100.4.1.10.1.7
The sensor reading shown as a string (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

otherNumericSensorValueInt 1.3.6.1.4.1.5528.100.4.1.10.1.8
The value measured by the sensor in the unit of measure (1/10 of otherNumericSensorValue)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

otherNumericSensorUnits 1.3.6.1.4.1.5528.100.4.1.10.1.9
The unit of measure for the sensor value.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

otherNumericSensorValueIntX1000 1.3.6.1.4.1.5528.100.4.1.10.1.10
The value measured by the sensor in thousandths of the unit of measure (100 times otherNumericSensorValue)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

otherNumericSensorValueIntX1000000 1.3.6.1.4.1.5528.100.4.1.10.1.11
The value measured by the sensor in millionths of the unit of measure (100000 times otherNumericSensorValue)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

otherNumericSensorIndex 1.3.6.1.4.1.5528.100.4.1.10.1.12
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dryContactSensorTable 1.3.6.1.4.1.5528.100.4.2.1
A list of dry contact sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DryContactSensorEntry

dryContactSensorEntry 1.3.6.1.4.1.5528.100.4.2.1.1
Dry contact sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  DryContactSensorEntry  

dryContactSensorId 1.3.6.1.4.1.5528.100.4.2.1.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

dryContactSensorValue 1.3.6.1.4.1.5528.100.4.2.1.1.2
Whether the dry sensor contact is open or closed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER null(-1), open(0), closed(1)  

dryContactSensorErrorStatus 1.3.6.1.4.1.5528.100.4.2.1.1.3
The operational status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

dryContactSensorLabel 1.3.6.1.4.1.5528.100.4.2.1.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dryContactSensorEncId 1.3.6.1.4.1.5528.100.4.2.1.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

dryContactSensorPortId 1.3.6.1.4.1.5528.100.4.2.1.1.6
The id of the port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

dryContactSensorValueStr 1.3.6.1.4.1.5528.100.4.2.1.1.7
The enum value label for the state reported by the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dryContactSensorIndex 1.3.6.1.4.1.5528.100.4.2.1.1.8
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

doorSwitchSensorTable 1.3.6.1.4.1.5528.100.4.2.2
A list of door switch sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DoorSwitchSensorEntry

doorSwitchSensorEntry 1.3.6.1.4.1.5528.100.4.2.2.1
Door switch sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  DoorSwitchSensorEntry  

doorSwitchSensorId 1.3.6.1.4.1.5528.100.4.2.2.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

doorSwitchSensorValue 1.3.6.1.4.1.5528.100.4.2.2.1.2
Whether the door is open or closed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER null(-1), open(0), closed(1)  

doorSwitchSensorErrorStatus 1.3.6.1.4.1.5528.100.4.2.2.1.3
The operational status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

doorSwitchSensorLabel 1.3.6.1.4.1.5528.100.4.2.2.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

doorSwitchSensorEncId 1.3.6.1.4.1.5528.100.4.2.2.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

doorSwitchSensorPortId 1.3.6.1.4.1.5528.100.4.2.2.1.6
The id of the port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

doorSwitchSensorValueStr 1.3.6.1.4.1.5528.100.4.2.2.1.7
The enum value label for the state reported by the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

doorSwitchSensorIndex 1.3.6.1.4.1.5528.100.4.2.2.1.8
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cameraMotionSensorTable 1.3.6.1.4.1.5528.100.4.2.3
A list of camera motion sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CameraMotionSensorEntry

cameraMotionSensorEntry 1.3.6.1.4.1.5528.100.4.2.3.1
Camera motion sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  CameraMotionSensorEntry  

cameraMotionSensorId 1.3.6.1.4.1.5528.100.4.2.3.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

cameraMotionSensorValue 1.3.6.1.4.1.5528.100.4.2.3.1.2
Whether motion is detected by the camera sensor.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER null(-1), noMotion(0), motionDetected(1)  

cameraMotionSensorErrorStatus 1.3.6.1.4.1.5528.100.4.2.3.1.3
The operational status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

cameraMotionSensorLabel 1.3.6.1.4.1.5528.100.4.2.3.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cameraMotionSensorEncId 1.3.6.1.4.1.5528.100.4.2.3.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

cameraMotionSensorPortId 1.3.6.1.4.1.5528.100.4.2.3.1.6
The id of the port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

cameraMotionSensorValueStr 1.3.6.1.4.1.5528.100.4.2.3.1.7
The enum value label for the state reported by the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cameraMotionSensorIndex 1.3.6.1.4.1.5528.100.4.2.3.1.8
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

otherStateSensorTable 1.3.6.1.4.1.5528.100.4.2.10
A list of other state sensor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OtherStateSensorEntry

otherStateSensorEntry 1.3.6.1.4.1.5528.100.4.2.10.1
Other state sensor entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  OtherStateSensorEntry  

otherStateSensorId 1.3.6.1.4.1.5528.100.4.2.10.1.1
The unique id of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

otherStateSensorValue 1.3.6.1.4.1.5528.100.4.2.10.1.2
State value reported by the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

otherStateSensorErrorStatus 1.3.6.1.4.1.5528.100.4.2.10.1.3
The operational status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

otherStateSensorLabel 1.3.6.1.4.1.5528.100.4.2.10.1.4
The unique label assigned to the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

otherStateSensorEncId 1.3.6.1.4.1.5528.100.4.2.10.1.5
The id of the physical enclosure containing the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

otherStateSensorPortId 1.3.6.1.4.1.5528.100.4.2.10.1.6
The id of port the sensor is plugged into (or empty string if it is not plugged into a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

otherStateSensorValueStr 1.3.6.1.4.1.5528.100.4.2.10.1.7
The enum value label for the state reported by the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

otherStateSensorIndex 1.3.6.1.4.1.5528.100.4.2.10.1.8
The index of the sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

errorCondTable 1.3.6.1.4.1.5528.100.5.1
A list of active and resolved error conditions.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ErrorCondEntry

errorCondEntry 1.3.6.1.4.1.5528.100.5.1.1
Error condition entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ErrorCondEntry  

errorCondId 1.3.6.1.4.1.5528.100.5.1.1.1
The unique id of the error condition.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

errorCondSeverity 1.3.6.1.4.1.5528.100.5.1.1.2
The relative severity of the error condition.
Status: current Access: read-only
OBJECT-TYPE    
  ErrorStatus  

errorCondTypeId 1.3.6.1.4.1.5528.100.5.1.1.3
The error type id reported for the error condition.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

errorCondStartTime 1.3.6.1.4.1.5528.100.5.1.1.4
The start time of the error condition, in msec since 1/1/1970.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

errorCondStartTimeStr 1.3.6.1.4.1.5528.100.5.1.1.5
The start time of the error condition, as ISO date-time formatted string (UTC).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

errorCondResolved 1.3.6.1.4.1.5528.100.5.1.1.6
Whether the error condition was resolved.
Status: current Access: read-only
OBJECT-TYPE    
  BoolValue  

errorCondResolvedTime 1.3.6.1.4.1.5528.100.5.1.1.7
The time the error condition was resolved (if it was resolved), in msec since 1/1/1970.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

errorCondResolvedTimeStr 1.3.6.1.4.1.5528.100.5.1.1.8
The time the error condition was resolved (if it was resolved), as ISO date-time formatted string (UTC).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

errorCondEncId 1.3.6.1.4.1.5528.100.5.1.1.9
The id of the physical enclosure associated with the error.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

errorCondPortId 1.3.6.1.4.1.5528.100.5.1.1.10
The id of the port associated with the error (or empty string if the error is not associated with a port).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

errorCondSensorId 1.3.6.1.4.1.5528.100.5.1.1.11
The id of the sensor associated with the error (or empty string if the error is not associated with a sensor.)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

errorCondIndex 1.3.6.1.4.1.5528.100.5.1.1.12
The index of the error condition.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

netBotzTrapErrorID 1.3.6.1.4.1.5528.100.11.1
Unique ID of error condition that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

netBotzTrapErrorType 1.3.6.1.4.1.5528.100.11.2
Symbolic ID of error type
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

netBotzTrapErrorTypeLabel 1.3.6.1.4.1.5528.100.11.3
Label for error type
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

netBotzTrapSensorID 1.3.6.1.4.1.5528.100.11.4
ID of sensor associated with error condition that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

netBotzTrapSensorLabel 1.3.6.1.4.1.5528.100.11.5
Label of sensor associated with error condition that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

netBotzTrapPodID 1.3.6.1.4.1.5528.100.11.6
ID of pod associated with error condition that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

netBotzTrapPodLabel 1.3.6.1.4.1.5528.100.11.7
Label of pod associated with error condition that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

netBotzTrapPortID 1.3.6.1.4.1.5528.100.11.8
ID of port associated with error condition that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

netBotzTrapPortLabel 1.3.6.1.4.1.5528.100.11.9
Label of port associated with error condition that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

netBotzTrapStartTime 1.3.6.1.4.1.5528.100.11.10
Start time (in UTC seconds) for error that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

netBotzTrapNotifyTime 1.3.6.1.4.1.5528.100.11.11
Notification time (in UTC seconds) for error that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

netBotzTrapResolveTime 1.3.6.1.4.1.5528.100.11.12
Resolve time (in UTC seconds) for error that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

netBotzTrapSeverity 1.3.6.1.4.1.5528.100.11.13
Severity of error that produced the trap
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER information(0), warning(1), error(2), critical(3), failure(4)  

netBotzTrapSensorValue 1.3.6.1.4.1.5528.100.11.14
String presentation of value of sensor
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

netBotzTrapSensorValueInt 1.3.6.1.4.1.5528.100.11.15
Whole integer representation of value of sensor (without decimal portion)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

netBotzTrapSensorValueFraction 1.3.6.1.4.1.5528.100.11.16
Fractional portion of value of sensor (multiplied by 1000000)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

netBotzTempTooHigh 1.3.6.1.4.1.5528.100.10.2.1.0.2
Temperature sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempTooHighRTN 1.3.6.1.4.1.5528.100.10.2.1.0.102
Temperature sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempTooLow 1.3.6.1.4.1.5528.100.10.2.1.0.3
Temperature sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempTooLowRTN 1.3.6.1.4.1.5528.100.10.2.1.0.103
Temperature sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.1.0.4
Temperature sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.1.0.104
Temperature sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.1.0.5
Temperature sensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.1.0.105
Temperature sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempUnplugged 1.3.6.1.4.1.5528.100.10.2.1.0.6
Temperature sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempReplugged 1.3.6.1.4.1.5528.100.10.2.1.0.106
Temperature sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.1.0.8
Temperature sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.1.0.108
Temperature sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.1.0.9
Temperature sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.1.0.109
Temperature sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempError 1.3.6.1.4.1.5528.100.10.2.1.0.1
Temperature sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTempErrorRTN 1.3.6.1.4.1.5528.100.10.2.1.0.101
Temperature sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityTooHigh 1.3.6.1.4.1.5528.100.10.2.2.0.2
Humidity sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityTooHighRTN 1.3.6.1.4.1.5528.100.10.2.2.0.102
Humidity sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityTooLow 1.3.6.1.4.1.5528.100.10.2.2.0.3
Humidity sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityTooLowRTN 1.3.6.1.4.1.5528.100.10.2.2.0.103
Humidity sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.2.0.4
Humidity sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.2.0.104
Humidity sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.2.0.5
Humidity sensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.2.0.105
Humidity sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityUnplugged 1.3.6.1.4.1.5528.100.10.2.2.0.6
Humidity sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityReplugged 1.3.6.1.4.1.5528.100.10.2.2.0.106
Humidity sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.2.0.8
Humidity sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.2.0.108
Humidity sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.2.0.9
Humidity sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.2.0.109
Humidity sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityError 1.3.6.1.4.1.5528.100.10.2.2.0.1
Humidity sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzHumidityErrorRTN 1.3.6.1.4.1.5528.100.10.2.2.0.101
Humidity sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointTooHigh 1.3.6.1.4.1.5528.100.10.2.3.0.2
DewPoint sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointTooHighRTN 1.3.6.1.4.1.5528.100.10.2.3.0.102
DewPoint sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointTooLow 1.3.6.1.4.1.5528.100.10.2.3.0.3
DewPoint sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointTooLowRTN 1.3.6.1.4.1.5528.100.10.2.3.0.103
DewPoint sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.3.0.4
DewPoint sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.3.0.104
DewPoint sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.3.0.5
DewPoint sensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.3.0.105
DewPoint sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointUnplugged 1.3.6.1.4.1.5528.100.10.2.3.0.6
DewPoint sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointReplugged 1.3.6.1.4.1.5528.100.10.2.3.0.106
DewPoint sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.3.0.8
DewPoint sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.3.0.108
DewPoint sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.3.0.9
DewPoint sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.3.0.109
DewPoint sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointError 1.3.6.1.4.1.5528.100.10.2.3.0.1
DewPoint sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDewPointErrorRTN 1.3.6.1.4.1.5528.100.10.2.3.0.101
DewPoint sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowTooHigh 1.3.6.1.4.1.5528.100.10.2.4.0.2
AirFlow sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowTooHighRTN 1.3.6.1.4.1.5528.100.10.2.4.0.102
AirFlow sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowTooLow 1.3.6.1.4.1.5528.100.10.2.4.0.3
AirFlow sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowTooLowRTN 1.3.6.1.4.1.5528.100.10.2.4.0.103
AirFlow sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.4.0.4
AirFlow sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.4.0.104
AirFlow sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.4.0.5
AirFlow sensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.4.0.105
AirFlow sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowUnplugged 1.3.6.1.4.1.5528.100.10.2.4.0.6
AirFlow sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowReplugged 1.3.6.1.4.1.5528.100.10.2.4.0.106
AirFlow sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.4.0.8
AirFlow sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.4.0.108
AirFlow sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.4.0.9
AirFlow sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.4.0.109
AirFlow sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowError 1.3.6.1.4.1.5528.100.10.2.4.0.1
AirFlow sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAirFlowErrorRTN 1.3.6.1.4.1.5528.100.10.2.4.0.101
AirFlow sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioTooHigh 1.3.6.1.4.1.5528.100.10.2.5.0.2
Audio sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioTooHighRTN 1.3.6.1.4.1.5528.100.10.2.5.0.102
Audio sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioTooLow 1.3.6.1.4.1.5528.100.10.2.5.0.3
Audio sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioTooLowRTN 1.3.6.1.4.1.5528.100.10.2.5.0.103
Audio sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.5.0.4
Audio sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.5.0.104
Audio sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.5.0.5
Audio sensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.5.0.105
Audio sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioUnplugged 1.3.6.1.4.1.5528.100.10.2.5.0.6
Audio sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioReplugged 1.3.6.1.4.1.5528.100.10.2.5.0.106
Audio sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.5.0.8
Audio sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.5.0.108
Audio sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.5.0.9
Audio sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.5.0.109
Audio sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioError 1.3.6.1.4.1.5528.100.10.2.5.0.1
Audio sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAudioErrorRTN 1.3.6.1.4.1.5528.100.10.2.5.0.101
Audio sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectTooHigh 1.3.6.1.4.1.5528.100.10.2.6.0.2
Amp Detectsensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectTooHighRTN 1.3.6.1.4.1.5528.100.10.2.6.0.102
Amp Detectsensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectTooLow 1.3.6.1.4.1.5528.100.10.2.6.0.3
Amp Detectsensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectTooLowRTN 1.3.6.1.4.1.5528.100.10.2.6.0.103
Amp Detectsensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.6.0.4
Amp Detectsensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.6.0.104
Amp Detectsensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.6.0.5
Amp Detectsensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.6.0.105
Amp Detectsensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectUnplugged 1.3.6.1.4.1.5528.100.10.2.6.0.6
Amp Detectsensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectReplugged 1.3.6.1.4.1.5528.100.10.2.6.0.106
Amp Detectsensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.6.0.8
Amp Detectsensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.6.0.108
Amp Detectsensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.6.0.9
Amp Detectsensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.6.0.109
Amp Detectsensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectError 1.3.6.1.4.1.5528.100.10.2.6.0.1
Amp Detectsensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzAmpDetectErrorRTN 1.3.6.1.4.1.5528.100.10.2.6.0.101
Amp Detectsensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDryContactUnplugged 1.3.6.1.4.1.5528.100.10.2.7.0.6
Dry Contact sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDryContactReplugged 1.3.6.1.4.1.5528.100.10.2.7.0.106
Dry Contact sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDryContactError 1.3.6.1.4.1.5528.100.10.2.7.0.1
Dry Contact sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDryContactErrorRTN 1.3.6.1.4.1.5528.100.10.2.7.0.101
Dry Contact sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDryContactValueError 1.3.6.1.4.1.5528.100.10.2.7.0.10
Dry Contact sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDryContactValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.7.0.110
Dry Contact sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzCameraMotionSensorUnplugged 1.3.6.1.4.1.5528.100.10.2.8.0.6
Camera Motion Sensor sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzCameraMotionSensorReplugged 1.3.6.1.4.1.5528.100.10.2.8.0.106
Camera Motion Sensor sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzCameraMotionSensorError 1.3.6.1.4.1.5528.100.10.2.8.0.1
Camera Motion Sensor sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzCameraMotionSensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.8.0.101
Camera Motion Sensor sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzCameraMotionSensorValueError 1.3.6.1.4.1.5528.100.10.2.8.0.10
Camera Motion Sensor sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzCameraMotionSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.8.0.110
Camera Motion Sensor sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDoorSensorUnplugged 1.3.6.1.4.1.5528.100.10.2.9.0.6
Door Sensor sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDoorSensorReplugged 1.3.6.1.4.1.5528.100.10.2.9.0.106
Door Sensor sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDoorSensorError 1.3.6.1.4.1.5528.100.10.2.9.0.1
Door Sensor sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDoorSensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.9.0.101
Door Sensor sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDoorSensorValueError 1.3.6.1.4.1.5528.100.10.2.9.0.10
Door Sensor sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDoorSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.9.0.110
Door Sensor sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMicPlugSensorUnplugged 1.3.6.1.4.1.5528.100.10.2.10.0.6
MicPlug Sensor sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMicPlugSensorReplugged 1.3.6.1.4.1.5528.100.10.2.10.0.106
MicPlug Sensor sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMicPlugSensorError 1.3.6.1.4.1.5528.100.10.2.10.0.1
MicPlug Sensor sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMicPlugSensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.10.0.101
MicPlug Sensor sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMicPlugSensorValueError 1.3.6.1.4.1.5528.100.10.2.10.0.10
MicPlug Sensor sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMicPlugSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.10.0.110
MicPlug Sensor sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSpeakerPlugSensorUnplugged 1.3.6.1.4.1.5528.100.10.2.11.0.6
SpeakerPlug Sensor sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSpeakerPlugSensorReplugged 1.3.6.1.4.1.5528.100.10.2.11.0.106
SpeakerPlug Sensor sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSpeakerPlugSensorError 1.3.6.1.4.1.5528.100.10.2.11.0.1
SpeakerPlug Sensor sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSpeakerPlugSensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.11.0.101
SpeakerPlug Sensor sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSpeakerPlugSensorValueError 1.3.6.1.4.1.5528.100.10.2.11.0.10
SpeakerPlug Sensor sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSpeakerPlugSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.11.0.110
SpeakerPlug Sensor sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTVSignalSensorUnplugged 1.3.6.1.4.1.5528.100.10.2.12.0.6
TVSignal Sensor sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTVSignalSensorReplugged 1.3.6.1.4.1.5528.100.10.2.12.0.106
TVSignal Sensor sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTVSignalSensorError 1.3.6.1.4.1.5528.100.10.2.12.0.1
TVSignal Sensor sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTVSignalSensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.12.0.101
TVSignal Sensor sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTVSignalSensorValueError 1.3.6.1.4.1.5528.100.10.2.12.0.10
TVSignal Sensor sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzTVSignalSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.12.0.110
TVSignal Sensor sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPodUnplugged 1.3.6.1.4.1.5528.100.10.3.0.7
Pod unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPodReplugged 1.3.6.1.4.1.5528.100.10.3.0.107
Pod no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSensorPodUnplugged 1.3.6.1.4.1.5528.100.10.3.2.0.7
Sensor Pod unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSensorPodReplugged 1.3.6.1.4.1.5528.100.10.3.2.0.107
Sensor Pod no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzCameraPodUnplugged 1.3.6.1.4.1.5528.100.10.3.3.0.7
Camera Pod unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzCameraPodReplugged 1.3.6.1.4.1.5528.100.10.3.3.0.107
Camera Pod no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzCCTVPodUnplugged 1.3.6.1.4.1.5528.100.10.3.4.0.7
CCTV Pod unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzCCTVPodReplugged 1.3.6.1.4.1.5528.100.10.3.4.0.107
CCTV Pod no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotz4to20mAPodUnplugged 1.3.6.1.4.1.5528.100.10.3.5.0.7
4-20mA Pod unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotz4to20mAPodReplugged 1.3.6.1.4.1.5528.100.10.3.5.0.107
4-20mA Pod no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLogonError 1.3.6.1.4.1.5528.100.10.3.0.11
Multiple failed logon attempts.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLogonErrorResolved 1.3.6.1.4.1.5528.100.10.3.0.111
Failed logon attempts stopped, or logon succeeded.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDriveNotFoundError 1.3.6.1.4.1.5528.100.10.3.0.12
Configured add-on drive not found or has malfunctioned.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzDriveNotFoundErrorResolved 1.3.6.1.4.1.5528.100.10.3.0.112
Missing add-on drive has bee found.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzRmtLinkError 1.3.6.1.4.1.5528.100.10.3.0.13
Configured remote link has failed.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzRmtLinkErrorResolved 1.3.6.1.4.1.5528.100.10.3.0.113
Configured remote link has returned to normal.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionTooHigh 1.3.6.1.4.1.5528.100.10.2.13.0.2
GPS Position sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionTooHighRTN 1.3.6.1.4.1.5528.100.10.2.13.0.102
GPS Position sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionTooLow 1.3.6.1.4.1.5528.100.10.2.13.0.3
GPS Position sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionTooLowRTN 1.3.6.1.4.1.5528.100.10.2.13.0.103
GPS Position sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.13.0.4
GPS Position sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.13.0.104
GPS Position sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.13.0.5
GPS Position ensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.13.0.105
GPS Position sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionUnplugged 1.3.6.1.4.1.5528.100.10.2.13.0.6
GPS Position sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionReplugged 1.3.6.1.4.1.5528.100.10.2.13.0.106
GPS Position sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.13.0.8
GPS Position sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.13.0.108
GPS Position sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.13.0.9
GPS Position sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.13.0.109
GPS Position sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionError 1.3.6.1.4.1.5528.100.10.2.13.0.1
GPS Position sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSPositionErrorRTN 1.3.6.1.4.1.5528.100.10.2.13.0.101
GPS Position sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementTooHigh 1.3.6.1.4.1.5528.100.10.2.14.0.2
GPS Movement sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementTooHighRTN 1.3.6.1.4.1.5528.100.10.2.14.0.102
GPS Movement sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementTooLow 1.3.6.1.4.1.5528.100.10.2.14.0.3
GPS Movement sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementTooLowRTN 1.3.6.1.4.1.5528.100.10.2.14.0.103
GPS Movement sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.14.0.4
GPS Movement sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.14.0.104
GPS Movement sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.14.0.5
GPS Movement ensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.14.0.105
GPS Movement sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementUnplugged 1.3.6.1.4.1.5528.100.10.2.14.0.6
GPS Movement sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementReplugged 1.3.6.1.4.1.5528.100.10.2.14.0.106
GPS Movement sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.14.0.8
GPS Movement sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.14.0.108
GPS Movement sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.14.0.9
GPS Movement sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.14.0.109
GPS Movement sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementError 1.3.6.1.4.1.5528.100.10.2.14.0.1
GPS Movement sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSMovementErrorRTN 1.3.6.1.4.1.5528.100.10.2.14.0.101
GPS Movement sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropTooHigh 1.3.6.1.4.1.5528.100.10.2.23.0.2
Packet Drop sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropTooHighRTN 1.3.6.1.4.1.5528.100.10.2.23.0.102
Packet Drop sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropTooLow 1.3.6.1.4.1.5528.100.10.2.23.0.3
Packet Drop sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropTooLowRTN 1.3.6.1.4.1.5528.100.10.2.23.0.103
Packet Drop sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.23.0.4
Packet Drop sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.23.0.104
Packet Drop sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.23.0.5
Packet Drop ensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.23.0.105
Packet Drop sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropUnplugged 1.3.6.1.4.1.5528.100.10.2.23.0.6
Packet Drop sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropReplugged 1.3.6.1.4.1.5528.100.10.2.23.0.106
Packet Drop sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.23.0.8
Packet Drop sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.23.0.108
Packet Drop sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.23.0.9
Packet Drop sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.23.0.109
Packet Drop sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropError 1.3.6.1.4.1.5528.100.10.2.23.0.1
Packet Drop sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPacketDropErrorRTN 1.3.6.1.4.1.5528.100.10.2.23.0.101
Packet Drop sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerTooHigh 1.3.6.1.4.1.5528.100.10.2.24.0.2
SNMP Crawler sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerTooHighRTN 1.3.6.1.4.1.5528.100.10.2.24.0.102
SNMP Crawler sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerTooLow 1.3.6.1.4.1.5528.100.10.2.24.0.3
SNMP Crawler sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerTooLowRTN 1.3.6.1.4.1.5528.100.10.2.24.0.103
SNMP Crawler sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.24.0.4
SNMP Crawler sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.24.0.104
SNMP Crawler sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.24.0.5
SNMP Crawler ensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.24.0.105
SNMP Crawler sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerUnplugged 1.3.6.1.4.1.5528.100.10.2.24.0.6
SNMP Crawler sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerReplugged 1.3.6.1.4.1.5528.100.10.2.24.0.106
SNMP Crawler sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.24.0.8
SNMP Crawler sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.24.0.108
SNMP Crawler sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.24.0.9
SNMP Crawler sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.24.0.109
SNMP Crawler sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerError 1.3.6.1.4.1.5528.100.10.2.24.0.1
SNMP Crawler sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerErrorRTN 1.3.6.1.4.1.5528.100.10.2.24.0.101
SNMP Crawler sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerSensorValueError 1.3.6.1.4.1.5528.100.10.2.24.0.10
SNMP Crawler Sensor sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzSNMPCrawlerSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.24.0.110
SNMP Crawler Sensor sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSStatusSensorUnplugged 1.3.6.1.4.1.5528.100.10.2.15.0.6
GPS Status Sensor sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSStatusSensorReplugged 1.3.6.1.4.1.5528.100.10.2.15.0.106
GPS Status Sensor sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSStatusSensorError 1.3.6.1.4.1.5528.100.10.2.15.0.1
GPS Status Sensor sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSStatusSensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.15.0.101
GPS Status Sensor sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSStatusSensorValueError 1.3.6.1.4.1.5528.100.10.2.15.0.10
GPS Status Sensor sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzGPSStatusSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.15.0.110
GPS Status Sensor sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzWirelessStatusSensorUnplugged 1.3.6.1.4.1.5528.100.10.2.22.0.6
Wireless Status Sensor sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzWirelessStatusSensorReplugged 1.3.6.1.4.1.5528.100.10.2.22.0.106
Wireless Status Sensor sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzWirelessStatusSensorError 1.3.6.1.4.1.5528.100.10.2.22.0.1
Wireless Status Sensor sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzWirelessStatusSensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.22.0.101
Wireless Status Sensor sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzWirelessStatusSensorValueError 1.3.6.1.4.1.5528.100.10.2.22.0.10
Wireless Status Sensor sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzWirelessStatusSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.22.0.110
Wireless Status Sensor sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPlugModuleStatusSensorUnplugged 1.3.6.1.4.1.5528.100.10.2.25.0.6
Power Control plug module unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPlugModuleStatusSensorReplugged 1.3.6.1.4.1.5528.100.10.2.25.0.106
Power Control plug module no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPlugModuleStatusSensorError 1.3.6.1.4.1.5528.100.10.2.25.0.1
Power Control plug module error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPlugModuleStatusSensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.25.0.101
Power Control plug module error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPlugModuleStatusSensorValueError 1.3.6.1.4.1.5528.100.10.2.25.0.10
Power Control plug module value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzPlugModuleStatusSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.25.0.110
Power Control plug module value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzOutputControlSensorUnplugged 1.3.6.1.4.1.5528.100.10.2.26.0.6
Output Control Sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzOutputControlSensorReplugged 1.3.6.1.4.1.5528.100.10.2.26.0.106
Output Control Sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzOutputControlSensorError 1.3.6.1.4.1.5528.100.10.2.26.0.1
Output Control Sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzOutputControlSensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.26.0.101
Output Control Sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzOutputControlSensorValueError 1.3.6.1.4.1.5528.100.10.2.26.0.10
Output Control Sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzOutputControlSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.26.0.110
Output Control Sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorTooHigh 1.3.6.1.4.1.5528.100.10.2.27.0.2
MultiRAE sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorTooHighRTN 1.3.6.1.4.1.5528.100.10.2.27.0.102
MultiRAE sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorTooLow 1.3.6.1.4.1.5528.100.10.2.27.0.3
MultiRAE sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorTooLowRTN 1.3.6.1.4.1.5528.100.10.2.27.0.103
MultiRAE sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.27.0.4
MultiRAE sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.27.0.104
MultiRAE sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.27.0.5
MultiRAE ensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.27.0.105
MultiRAE sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorUnplugged 1.3.6.1.4.1.5528.100.10.2.27.0.6
MultiRAE sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorReplugged 1.3.6.1.4.1.5528.100.10.2.27.0.106
MultiRAE sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.27.0.8
MultiRAE sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.27.0.108
MultiRAE sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.27.0.9
MultiRAE sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.27.0.109
MultiRAE sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorError 1.3.6.1.4.1.5528.100.10.2.27.0.1
MultiRAE sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.27.0.101
MultiRAE sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorSensorValueError 1.3.6.1.4.1.5528.100.10.2.27.0.10
MultiRAE Sensor sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.27.0.110
MultiRAE Sensor sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorStatusUnplugged 1.3.6.1.4.1.5528.100.10.2.28.0.6
MultiRAE Sensor Status unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorStatusReplugged 1.3.6.1.4.1.5528.100.10.2.28.0.106
MultiRAE Sensor Status no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorStatusError 1.3.6.1.4.1.5528.100.10.2.28.0.1
MultiRAE Sensor Status error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorStatusErrorRTN 1.3.6.1.4.1.5528.100.10.2.28.0.101
MultiRAE Sensor Status error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorStatusValueError 1.3.6.1.4.1.5528.100.10.2.28.0.10
MultiRAE Sensor Status value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAESensorStatusValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.28.0.110
MultiRAE Sensor Status value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAEDeviceStatusUnplugged 1.3.6.1.4.1.5528.100.10.2.29.0.6
MultiRAE Device Status unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAEDeviceStatusReplugged 1.3.6.1.4.1.5528.100.10.2.29.0.106
MultiRAE Device Status no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAEDeviceStatusError 1.3.6.1.4.1.5528.100.10.2.29.0.1
MultiRAE Device Status error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAEDeviceStatusErrorRTN 1.3.6.1.4.1.5528.100.10.2.29.0.101
MultiRAE Device Status error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAEDeviceStatusValueError 1.3.6.1.4.1.5528.100.10.2.29.0.10
MultiRAE Device Status value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzMultiRAEDeviceStatusValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.29.0.110
MultiRAE Device Status value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLinkStatusSensorUnplugged 1.3.6.1.4.1.5528.100.10.2.30.0.6
Link Status sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLinkStatusSensorReplugged 1.3.6.1.4.1.5528.100.10.2.30.0.106
Link Status sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLinkStatusSensorError 1.3.6.1.4.1.5528.100.10.2.30.0.1
Link Status sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLinkStatusSensorErrorRTN 1.3.6.1.4.1.5528.100.10.2.30.0.101
Link Status sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLinkStatusSensorValueError 1.3.6.1.4.1.5528.100.10.2.30.0.10
Link Status sensor value error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLinkStatusSensorValueErrorRTN 1.3.6.1.4.1.5528.100.10.2.30.0.110
Link Status sensor value error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageTooHigh 1.3.6.1.4.1.5528.100.10.2.31.0.2
Loop Voltage sensor value too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageTooHighRTN 1.3.6.1.4.1.5528.100.10.2.31.0.102
Loop Voltage sensor value is no longer too high.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageTooLow 1.3.6.1.4.1.5528.100.10.2.31.0.3
Loop Voltage sensor value too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageTooLowRTN 1.3.6.1.4.1.5528.100.10.2.31.0.103
Loop Voltage sensor value is no longer too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageTooHighTooLong 1.3.6.1.4.1.5528.100.10.2.31.0.4
Loop Voltage sensor value too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageTooHighTooLongRTN 1.3.6.1.4.1.5528.100.10.2.31.0.104
Loop Voltage sensor value is no longer too high for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageTooLowTooLong 1.3.6.1.4.1.5528.100.10.2.31.0.5
Loop Voltage sensor value too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageTooLowForTooLongRTN 1.3.6.1.4.1.5528.100.10.2.31.0.105
Loop Voltage sensor value is no longer too low for too long.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageUnplugged 1.3.6.1.4.1.5528.100.10.2.31.0.6
Loop Voltage sensor unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageReplugged 1.3.6.1.4.1.5528.100.10.2.31.0.106
Loop Voltage sensor no longer unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.31.0.8
Loop Voltage sensor value increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageNotIncreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.31.0.108
Loop Voltage sensor value no longer increasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.31.0.9
Loop Voltage sensor value decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageNotDecreasingTooQuickly 1.3.6.1.4.1.5528.100.10.2.31.0.109
Loop Voltage sensor value no longer decreasing too quickly.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageError 1.3.6.1.4.1.5528.100.10.2.31.0.1
Loop Voltage sensor error.
Status: current Access: read-only
NOTIFICATION-TYPE    

netBotzLoopVoltageErrorRTN 1.3.6.1.4.1.5528.100.10.2.31.0.101
Loop Voltage sensor error resolved.
Status: current Access: read-only
NOTIFICATION-TYPE