MSERIES-PORT-MIB

File: MSERIES-PORT-MIB.mib (6664 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
MSERIES-TC MSERIES-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Unsigned32
Integer32 DisplayString OBJECT-GROUP
MODULE-COMPLIANCE PortType PortStatus
PortMode mseries

Defined Types

SmartPortEntry  
SEQUENCE    
  smartPortIndex Unsigned32
  smartPortName DisplayString
  smartPortAlias DisplayString
  smartPortType PortType
  smartPortPower Integer32
  smartPortStatus PortStatus
  smartPortMode PortMode
  smartPortHighPowerAlarmThreshold Integer32
  smartPortLowPowerAlarmThreshold Integer32

Defined Values

smartPort 1.3.6.1.4.1.30826.1.3
This is the enterprise specific Port MIB for SmartOptics M-Series.
MODULE-IDENTITY    

smartPortObjects 1.3.6.1.4.1.30826.1.3.1
OBJECT IDENTIFIER    

smartPortGeneral 1.3.6.1.4.1.30826.1.3.1.1
OBJECT IDENTIFIER    

smartPortList 1.3.6.1.4.1.30826.1.3.1.2
OBJECT IDENTIFIER    

smartPortMIBConformance 1.3.6.1.4.1.30826.1.3.2
OBJECT IDENTIFIER    

smartPortGroups 1.3.6.1.4.1.30826.1.3.2.1
OBJECT IDENTIFIER    

smartPortCompliances 1.3.6.1.4.1.30826.1.3.2.2
OBJECT IDENTIFIER    

smartPortTable 1.3.6.1.4.1.30826.1.3.1.2.1
A port table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SmartPortEntry

smartPortEntry 1.3.6.1.4.1.30826.1.3.1.2.1.1
An entry in the port list.
Status: current Access: not-accessible
OBJECT-TYPE    
  SmartPortEntry  

smartPortIndex 1.3.6.1.4.1.30826.1.3.1.2.1.1.1
A unique index for each port that corresponds to the index in the interface table
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..2147483647  

smartPortName 1.3.6.1.4.1.30826.1.3.1.2.1.1.2
The name of the port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

smartPortAlias 1.3.6.1.4.1.30826.1.3.1.2.1.1.3
User configurable Port Alias for the port. Not writeable in SmartOS v2.3
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

smartPortType 1.3.6.1.4.1.30826.1.3.1.2.1.1.4
The type of port. rx(1) - Receiving port. tx(2) - Transmitting port. biDi(3) - Bidirectional port.
Status: current Access: read-only
OBJECT-TYPE    
  PortType  

smartPortPower 1.3.6.1.4.1.30826.1.3.1.2.1.1.5
The power level in units of 0.1 dBm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

smartPortStatus 1.3.6.1.4.1.30826.1.3.1.2.1.1.6
The operational state for a port. idle(1) - The port is not activated down(2) - The port traffic is lost. up(3) - There is traffic on the port. high(4) - The port got to high power. low(5) - The port got to low power. eyeSafety(6) - The Line Tx port is in Eye Safety Mode. This means that either the connector on the Line Tx port is not inserted or that you have too strong reflection from the line fiber. cd(7) - Channel detected. ncd(8) - No channel detected.
Status: current Access: read-only
OBJECT-TYPE    
  PortStatus  

smartPortMode 1.3.6.1.4.1.30826.1.3.1.2.1.1.7
The Mode of the Port. normal (1) - The port is active. No alarms are beeing suppressed. service (2) . The port is in service mode and alarms are beeing suppressed. When service is ready smartPortMode should be set to 'normal' again. Not writeable in SmartOS v2.3
Status: current Access: read-write
OBJECT-TYPE    
  PortMode  

smartPortHighPowerAlarmThreshold 1.3.6.1.4.1.30826.1.3.1.2.1.1.8
The threshold for the High Power alarm. Not writeable in SmartOS v2.3
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

smartPortLowPowerAlarmThreshold 1.3.6.1.4.1.30826.1.3.1.2.1.1.9
The threshold for the Low Power alarm. Not writeable in SmartOS v2.3
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

smartPortListGroupV1 1.3.6.1.4.1.30826.1.3.2.1.1
The Port List MIB objects v1.
Status: current Access: read-write
OBJECT-GROUP    

smartPortBasicComplV1 1.3.6.1.4.1.30826.1.3.2.2.1
Basic implementation requirements for the port MIB V1.
Status: current Access: read-write
MODULE-COMPLIANCE