MMB-COM-MIB

File: MMB-COM-MIB.mib (123918 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB
RFC1155-SMI INET-ADDRESS-MIB

Imported symbols

OBJECT-TYPE TRAP-TYPE mib-2
DisplayString PhysAddress TimeTicks
Counter Gauge IpAddress
mgmt enterprises InetAddressType
InetAddress

Defined Types

TrueFalse  
INTEGER false(1), true(2)    

TrueFalseUnknown  
INTEGER false(1), true(2), unknown(3)    

Units  
SEQUENCE    
  uUnitId INTEGER
  unitClass INTEGER
  unitCainetNr INTEGER
  unitDesignation DisplayString
  unitModelName DisplayString
  unitManufacturer DisplayString
  unitSerialNumber DisplayString
  unitLocation DisplayString
  unitContact DisplayString
  unitAdminURL DisplayString
  frontDoorStatus INTEGER
  housingOpenStatus INTEGER
  msgLogLanguages DisplayString
  unitWorldWideName DisplayString
  remcsId DisplayString
  assetTag DisplayString
  unitManagementIpAddress DisplayString
  unitManagementIpAddressV6 DisplayString

UnitParents  
SEQUENCE    
  pUnitId INTEGER
  pParentNr INTEGER
  parentUnit INTEGER
  parentUnitClass INTEGER

UnitChilds  
SEQUENCE    
  cUnitId INTEGER
  cChildNr INTEGER
  childUnit INTEGER
  childUnitClass INTEGER

ManagementNodes  
SEQUENCE    
  mnUnitId INTEGER
  mnNodeNr INTEGER
  unitNodeIfType INTEGER
  unitNodeAddress DisplayString
  unitNodeIpNetmask DisplayString
  unitNodeGateway DisplayString
  unitNodeName DisplayString
  unitNodeClass INTEGER
  unitNodeMacAddress PhysAddress
  unitNodeUseDHCP INTEGER
  unitNodeControllerType DisplayString
  unitNodeControllerModel DisplayString
  unitNodeControllerFWVersion DisplayString

ManagementProcessors  
SEQUENCE    
  spUnitId INTEGER
  spProcessorNr INTEGER
  spModelName DisplayString
  spFirmwareVersion DisplayString
  spBatteryStatus INTEGER
  spBatteryDischargeTime INTEGER
  spTimeOnBattery Counter
  spDoBatteryChargeCycle INTEGER
  spBatteryChargeLevel Gauge

ManagementUpsNodes  
SEQUENCE    
  upsUnitId INTEGER
  upsNr INTEGER
  upsVendorName DisplayString
  upsModelName DisplayString
  upsIpAddress DisplayString
  upsMibRoot DisplayString
  upsSnmpCommunity DisplayString
  upsHttpPort INTEGER

Servers  
SEQUENCE    
  srvUnitId INTEGER
  srvPhysicalMemory INTEGER
  srvLastBootResult INTEGER
  srvCurrentBootStatus INTEGER
  srvShutdownCommand INTEGER
  srvShutdownDelay INTEGER
  srvUUID DisplayString
  srvPhysicalMemoryOs INTEGER
  srvTpmMode INTEGER
  srvManagementIP DisplayString

UnitPowerOnOff  
SEQUENCE    
  ooUnitId INTEGER
  powerOnOffStatus INTEGER
  lastPowerOffSource INTEGER
  lastPowerOnSource INTEGER
  lastPowerOnTime INTEGER
  powerOnCounts INTEGER
  powerOnDuration INTEGER
  powerOffDuration INTEGER
  powerFailRecovery INTEGER
  powerCommand INTEGER
  powerSupplyRedundancy INTEGER

Performance  
SEQUENCE    
  perfUnitId INTEGER
  perfNr INTEGER
  perfType INTEGER
  performanceValue Gauge
  performanceName DisplayString

TimerOnOff  
SEQUENCE    
  tooUnitId INTEGER
  tooDayOfWeek INTEGER
  onTime INTEGER
  offTime INTEGER

PowerMonitoring  
SEQUENCE    
  pmUnitId INTEGER
  pmCurrentPowerMonitoringAvailable TrueFalse
  pmCurrentPowerMonitoringEnabled TrueFalse
  pmNominalPowerConsumption INTEGER
  pmCurrentPowerConsumption Gauge
  pmCurrentPowerControl INTEGER

UtilizationHistory  
SEQUENCE    
  uthUnitId INTEGER
  uthEntity INTEGER
  uthTimeStamp INTEGER
  uthHardwareUUID DisplayString
  uthAverageValue Gauge
  uthMinValue Gauge
  uthMaxValue Gauge

PowerSourceInformation  
SEQUENCE    
  psiUnitId INTEGER
  psiPowerSourceType DisplayString
  psiPowerSourcePhase INTEGER
  psiPowerSourceVoltage INTEGER

TemperatureSensors  
SEQUENCE    
  tempUnitId INTEGER
  tempSensorNr INTEGER
  tempSensorDesignation DisplayString
  tempSensorIdentifier DisplayString
  tempSensorStatus INTEGER
  tempCurrentTemperature INTEGER
  tempWarningLevel INTEGER
  tempCriticalLevel INTEGER
  tempCriticalReaction INTEGER

Fans  
SEQUENCE    
  fanUnitId INTEGER
  fanNr INTEGER
  fanDesignation DisplayString
  fanIdentifier DisplayString
  fanStatus INTEGER
  fanCurrentSpeed INTEGER
  fanQuality INTEGER
  fanFailReaction INTEGER
  fanFailShutdownDelay INTEGER

Airflow  
SEQUENCE    
  afUnitId INTEGER
  afExhaustAirflowVolume INTEGER
  afExhaustAirflowVolumeUnit DisplayString

SystemBoard  
SEQUENCE    
  sbUnitId INTEGER
  systemBoardModelName DisplayString
  systemBoardProductNumber DisplayString
  systemBoardRevision DisplayString
  systemBoardSerialNumber DisplayString

PowerSupply  
SEQUENCE    
  psUnitId INTEGER
  psPowerSupplyNr INTEGER
  powerSupplyDesignation DisplayString
  powerSupplyIdentifier DisplayString
  powerSupplyStatus INTEGER

Voltages  
SEQUENCE    
  voUnitId INTEGER
  voSensorNr INTEGER
  voltageDesignation DisplayString
  voltageStatus INTEGER
  voltageCurrentValue INTEGER
  voltageNominalValue INTEGER
  voltageMinimumLevel INTEGER
  voltageMaximumLevel INTEGER
  voltageCurrentLoad Gauge

Cpus  
SEQUENCE    
  cpuUnitId INTEGER
  cpuNr INTEGER
  cpuDesignation DisplayString
  cpuStatus INTEGER
  cpuModelName DisplayString
  cpuManufacturer DisplayString
  cpuStep DisplayString
  cpuCurrentSpeed INTEGER
  cpuNumberLogicals INTEGER
  cpuCacheL1Size INTEGER
  cpuCacheL2Size INTEGER
  cpuCacheL3Size INTEGER
  cpuNumberCores INTEGER
  cpuFamily INTEGER
  cpuEnabledCores INTEGER

MemoryModules  
SEQUENCE    
  memUnitId INTEGER
  memModuleNr INTEGER
  memModuleDesignation DisplayString
  memModuleStatus INTEGER
  memModuleBank INTEGER
  memModuleCapacity INTEGER
  memModuleStartAddress INTEGER
  memModuleForm DisplayString
  memModuleType DisplayString
  memModuleCorrErrors Counter
  memModuleUncorrErrors Counter
  memModuleApproved INTEGER
  memModuleConfiguration INTEGER
  memModuleFrequency INTEGER
  memModuleMaxFrequency INTEGER
  memModuleVoltInterface DisplayString

ComponentPowerConsumption  
SEQUENCE    
  cpcUnitId INTEGER
  cpcComponentClass INTEGER
  cpcComponentIndex INTEGER
  cpcDesignation DisplayString
  cpcCurrentValue INTEGER

TrustedPlatformModule  
SEQUENCE    
  tpmUnitId INTEGER
  tpmHardwareAvailable TrueFalseUnknown
  tpmBiosEnabled TrueFalseUnknown
  tpmEnabled TrueFalseUnknown
  tpmActivated TrueFalseUnknown
  tpmOwnership TrueFalseUnknown

MessageLogs  
SEQUENCE    
  msgUnitId INTEGER
  msgLogEntryNr INTEGER
  msgLogEntryData OCTET STRING

Watchdogs  
SEQUENCE    
  wdUnitId INTEGER
  watchdogType INTEGER
  watchdogStatus INTEGER
  watchdogEnable INTEGER
  watchdogTime INTEGER
  watchdogAction INTEGER

RecoverySettings  
SEQUENCE    
  asrUnitId INTEGER
  asrNrRebootRetries INTEGER
  asrDefaultRebootRetries INTEGER
  asrNextBootSource INTEGER
  asrRebootFailAction INTEGER
  asrRestartDelay INTEGER
  asrPostErrorHalt INTEGER

MessageTextLogs  
SEQUENCE    
  msgTextLogUnitId INTEGER
  msgTextLogLanguage INTEGER
  msgTextLogSeqNr INTEGER
  msgTextLogTimestamp INTEGER
  msgTextLogMessage DisplayString
  msgTextLogErrorCode INTEGER
  msgTextLogSeverity INTEGER
  msgTextLogCSSComponent TrueFalse

MessageLogActionHints  
SEQUENCE    
  mlaLanguage INTEGER
  mlaErrorCode INTEGER
  mlaType INTEGER
  mlaIndex INTEGER
  mlaMessage DisplayString

StatusComponents  
SEQUENCE    
  csUnitId INTEGER
  csType INTEGER
  componentStatusValue INTEGER

ComponentStatusSensors  
SEQUENCE    
  cssUnitId INTEGER
  cssSensorNumber INTEGER
  cssSensorDesignation DisplayString
  cssSensorDevice DisplayString
  cssSensorDeviceInstance INTEGER
  cssSensorPhysicalLed TrueFalse
  cssSensorCssComponent TrueFalse
  cssSensorStatus INTEGER
  cssComponentServicePartId DisplayString

MaintenanceObjects  
SEQUENCE    
  mtUnitId INTEGER
  errorCounterStartTime INTEGER
  sendTestTrap INTEGER
  addTrapDestination IpAddress
  mtMaintenanceStatus INTEGER

FirmwareVersions  
SEQUENCE    
  fwUnitId INTEGER
  fwType INTEGER
  fwModelName DisplayString
  fwVersion DisplayString
  fwLocation INTEGER

DeployInfo  
SEQUENCE    
  dplInfoUnitId INTEGER
  deployInfoChassisId DisplayString
  deployInfoMacAddr1 PhysAddress
  deployInfoMacAddr2 PhysAddress
  deployInfoMacAddr3 PhysAddress
  deployInfoMacAddr4 PhysAddress
  deployInfoIpAddr1 IpAddress
  deployInfoIpAddr2 IpAddress
  deployInfoIpAddr3 IpAddress
  deployInfoIpAddr4 IpAddress
  deployInfoNetMask1 IpAddress
  deployInfoNetMask2 IpAddress
  deployInfoNetMask3 IpAddress
  deployInfoNetMask4 IpAddress
  deployInfoGateway1 IpAddress
  deployInfoGateway2 IpAddress
  deployInfoGateway3 IpAddress
  deployInfoGateway4 IpAddress
  deployInfoHostname DisplayString
  deployInfoMasterImageReference DisplayString
  deployInfoStatusOfBlade INTEGER
  deployInfoLanStatusOfSlot INTEGER
  deployInfoAutomaticRecovery INTEGER
  deployInfoStatusOfCloning INTEGER
  deployInfoBootMode INTEGER

OemDeployInfo  
SEQUENCE    
  odplInfoUnitId INTEGER
  odplParamId INTEGER
  oemDeployInfoParamData DisplayString

DeployLanInterfaces  
SEQUENCE    
  dplLanUnitId INTEGER
  dplLanInterfaceNr INTEGER
  dplLanMacAddress PhysAddress

Defined Values

fujitsu 1.3.6.1.4.1.211
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.211.1
OBJECT IDENTIFIER    

iaServer 1.3.6.1.4.1.211.1.31
OBJECT IDENTIFIER    

primequest 1.3.6.1.4.1.211.1.31.1
OBJECT IDENTIFIER    

mmb 1.3.6.1.4.1.211.1.31.1.1
OBJECT IDENTIFIER    

partition 1.3.6.1.4.1.211.1.31.1.2
OBJECT IDENTIFIER    

sysInfo 1.3.6.1.4.1.211.1.31.1.1.1
OBJECT IDENTIFIER    

agentInfo 1.3.6.1.4.1.211.1.31.1.1.1.1
OBJECT IDENTIFIER    

unitInformation 1.3.6.1.4.1.211.1.31.1.1.1.2
OBJECT IDENTIFIER    

management 1.3.6.1.4.1.211.1.31.1.1.1.3
OBJECT IDENTIFIER    

serverInformation 1.3.6.1.4.1.211.1.31.1.1.1.4
OBJECT IDENTIFIER    

environment 1.3.6.1.4.1.211.1.31.1.1.1.5
OBJECT IDENTIFIER    

hardware 1.3.6.1.4.1.211.1.31.1.1.1.6
OBJECT IDENTIFIER    

recovery 1.3.6.1.4.1.211.1.31.1.1.1.7
OBJECT IDENTIFIER    

status 1.3.6.1.4.1.211.1.31.1.1.1.8
OBJECT IDENTIFIER    

maintenance 1.3.6.1.4.1.211.1.31.1.1.1.9
OBJECT IDENTIFIER    

deployment 1.3.6.1.4.1.211.1.31.1.1.1.10
OBJECT IDENTIFIER    

agentId 1.3.6.1.4.1.211.1.31.1.1.1.1.1
Agent identification string; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

agentCompany 1.3.6.1.4.1.211.1.31.1.1.1.1.2
Agent's company name (e.g. Fujitsu Siemens Computers); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

agentVersion 1.3.6.1.4.1.211.1.31.1.1.1.1.3
Agent's version string (e.g. 1.05); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

agentBuild 1.3.6.1.4.1.211.1.31.1.1.1.1.4
Compilation time and date of agent program; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

agentWriteAllowed 1.3.6.1.4.1.211.1.31.1.1.1.1.5
Defines whether writable objects can be written (except shutdown/power-off operations); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), write-not-allowed(2), write-allowed(3)  

agentShutdownAllowed 1.3.6.1.4.1.211.1.31.1.1.1.1.6
Defines whether shutdown/power-off objects can be written; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), shutdown-not-allowed(2), shutdown-allowed(3)  

localServerUnitId 1.3.6.1.4.1.211.1.31.1.1.1.2.1
Unit identifier number of the local server (usually is ID 1). This ID can be used as index into the units table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

numberUnits 1.3.6.1.4.1.211.1.31.1.1.1.2.2
Number of available units (size of units table).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unitTable 1.3.6.1.4.1.211.1.31.1.1.1.2.3
Description of all units in this MIB
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Units

units 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Units  

uUnitId 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unitClass 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.2
Unit classification (type)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER chassis(1), partition(2), free-pool(3), sb(4), iou(7), iou-divided(8), iou-nodivided(9), pci-box(10), fan-tray(17), op-panel(20), mmb(21), gspb(28), gspb-divided(29), gspb-nodivided(30), sas-unit(31), psu(32), dvdb(33), lpci-box(34), fan(35), du(36)  

unitCainetNr 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.3
Physical identification number or partition identification number of units. The ID of the 'chassis' is usually 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unitDesignation 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.4
Unit identification name. (e.g. 'SB#1') This object returns 'Part Number'; if the index shows chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitModelName 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.5
Unit model name (e.g. 'PRIMERGY PRIMEQUEST 3200 model xxx')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitManufacturer 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.6
Unit manufacturer name (e.g. 'Fujitsu')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitSerialNumber 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.7
Unit serial number (e.g. '0202456123')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitLocation 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.8
Unit location string (e.g. 'ServerCenter Room 17; Rack 9')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitContact 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.9
Unit contact name (e.g. 'Mr. Bond')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitAdminURL 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.10
URL of administration HTML interface(MMB-GUI) (e.g. 'http://MyServer/admin')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

frontDoorStatus 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.11
Status describing whether the front door is open or closed; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), open(2), close(3)  

housingOpenStatus 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.12
Status describing whether the housing is open or closed; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), open(2), close(3), opened-and-closed(4)  

msgLogLanguages 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.13
Supported languages of text message log (comma-seperated list of decimal language codes; see sc2MessageTextLogTable). e.g. '1031;1033' means German and English are supported. English (1033) is the default language and is always available; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitWorldWideName 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.14
Unit World Wide Name. A 64-bit sized address for storage devices (e.g. '6661E2B0A00B88FB'); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

remcsId 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.15
REMCS system identification string (binary data); Not supported. Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID for Company Name MM...M : 12byte : Model Name mm...m : 12byte : Device Name CC : 2byte : Checksum nn...n : 12byte : Serial number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

assetTag 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.16
Customer specific asset tag (40 bytes)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitManagementIpAddress 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.18
IPv4 address of the partition for management purpose (e.g. '192.168.0.140')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitManagementIpAddressV6 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.20
IPv6 address of the partition for management purpose (e.g. '2001:0db8:0000:85a3:0000:0000:ac1f:8001')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitTableUpdateCount 1.3.6.1.4.1.211.1.31.1.1.1.2.4
Counter defining the update revision of the unit table. This counter is incremented with every table contents change/update.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unitParentTable 1.3.6.1.4.1.211.1.31.1.1.1.2.5
Parent-child relationship of all units
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UnitParents

unitParents 1.3.6.1.4.1.211.1.31.1.1.1.2.5.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UnitParents  

pUnitId 1.3.6.1.4.1.211.1.31.1.1.1.2.5.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pParentNr 1.3.6.1.4.1.211.1.31.1.1.1.2.5.1.2
Parent number (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

parentUnit 1.3.6.1.4.1.211.1.31.1.1.1.2.5.1.3
Parent unit. This is the same value as in the object of 'pParentNr'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

parentUnitClass 1.3.6.1.4.1.211.1.31.1.1.1.2.5.1.4
Unit classification (type). This is the same value as in units table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER chassis(1), partition(2), free-pool(3), sb(4), iou(7), iou-divided(8), iou-nodivided(9), pci-box(10), fan-tray(17), op-panel(20), mmb(21), gspb(28), gspb-divided(29), gspb-nodivided(30), sas-unit(31), psu(32), dvdb(33), lpci-box(34), fan(35), du(36)  

unitChildTable 1.3.6.1.4.1.211.1.31.1.1.1.2.6
Parent-child relationship of all units
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UnitChilds

unitChilds 1.3.6.1.4.1.211.1.31.1.1.1.2.6.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UnitChilds  

cUnitId 1.3.6.1.4.1.211.1.31.1.1.1.2.6.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cChildNr 1.3.6.1.4.1.211.1.31.1.1.1.2.6.1.2
Child number (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

childUnit 1.3.6.1.4.1.211.1.31.1.1.1.2.6.1.3
Child unit. This is the same value as in the object of 'cChildNr'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

childUnitClass 1.3.6.1.4.1.211.1.31.1.1.1.2.6.1.4
Unit classification (type). This is the same value as in units table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER chassis(1), partition(2), free-pool(3), sb(4), iou(7), iou-divided(8), iou-nodivided(9), pci-box(10), fan-tray(17), op-panel(20), mmb(21), gspb(28), gspb-divided(29), gspb-nodivided(30), sas-unit(31), psu(32), dvdb(33), lpci-box(34), fan(35), du(36)  

parentChildTableUpdateCount 1.3.6.1.4.1.211.1.31.1.1.1.2.7
Counter defining the update revision of the parent-child unit table. This counter is incremented with every table contents change/update.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

managementNodeTable 1.3.6.1.4.1.211.1.31.1.1.1.3.1
SNMP management node addresses (how to address the units)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ManagementNodes

managementNodes 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ManagementNodes  

mnUnitId 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mnNodeNr 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.2
Management node address number (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unitNodeIfType 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.3
Management node interface type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ip(2), ipx(3), ipv6-ip(4), virtual-ip(5), ipv6-virtual-ip(6)  

unitNodeAddress 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.4
Management node address (e.g. 192.168.0.100)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitNodeIpNetmask 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.5
Management node address (e.g. 255.255.255.128)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitNodeGateway 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.6
Management node address (e.g. 192.168.0.126)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitNodeName 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.7
Management node name (e.g. 'primequest-no1')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitNodeClass 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.8
Management node class: primary: operating system interface secondary: remote management controller interface management-blade: management blade in blade server secondary-backup: backup remote management controller interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), primery(2), secondary(3), manegement-blade(4), secondary-remote(5), secondary-remote-backup(6), baseboard-controller(7), secondary-manegement-blade(8)  

unitNodeMacAddress 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.9
Management node hardware (MAC) address; ff:ff:ff:ff:ff:ff if value not available
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

unitNodeUseDHCP 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.10
Management node uses DHCP to obtain its address
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), use-fixed-address(2), use-dhcp(3)  

unitNodeControllerType 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.11
The type of the remote management controller (for identification); like 'RSB'; 'RSB S2'; 'RSB S2 LP'... These names will not be changed if defined once; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitNodeControllerModel 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.12
The model name of the remote management controller (for displaying); like 'Remote Service Board'; RemoteView Service Board S2'c This name should not be used for identification;only for displaying (can be changed in different firmware versions)! Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitNodeControllerFWVersion 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.13
The FW version of the remote management controller; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

nodeTableUpdateCount 1.3.6.1.4.1.211.1.31.1.1.1.3.2
Counter defining the update revision of the management node table. This counter is incremented with every table contents change/update.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

managementChannelType 1.3.6.1.4.1.211.1.31.1.1.1.3.3
The type of the management channel currently used (this MIB instance).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), primery(2), secondary(3)  

managementProcessorTable 1.3.6.1.4.1.211.1.31.1.1.1.3.4
System management service processors
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ManagementProcessors

managementProcessors 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ManagementProcessors  

spUnitId 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

spProcessorNr 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.2
Service processor number (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

spModelName 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.3
Service processor model name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

spFirmwareVersion 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.4
Service processor firmware version / revision
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

spBatteryStatus 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.5
Service processor backup battery status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), ok(3), on-battery(4), recharging(5), failed(6), discharging(7)  

spBatteryDischargeTime 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.6
Maximum time (in seconds) this backup battery can discharged. after that a shutdown will be performed (-1 = unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

spTimeOnBattery 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.7
Time (in seconds) the service processor is running on battery since power fail (will be cleared on power recovery); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

spDoBatteryChargeCycle 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.8
Perform a discharge/charge cycle on the backup battery by writing a non-zero value. Reading this object just returns the value 0; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

spBatteryChargeLevel 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.9
Reads the current charge level of the rechargeable battery (in percent of the maximum capacity); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

managedUpsNodeTable 1.3.6.1.4.1.211.1.31.1.1.1.3.5
UPS nodes managed by the units; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ManagementUpsNodes

managedUpsNodes 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ManagementUpsNodes  

upsUnitId 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.1
Unit identifier (index: 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsNr 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.2
UPS number (index: 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsVendorName 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.3
UPS vendor name; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

upsModelName 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.4
UPS model name; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

upsIpAddress 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.5
UPS IP address (represented as string; may also contain an IP V6 address); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

upsMibRoot 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.6
UPS MIB root OID; specifies the root OID of the MIB to be used to query UPS via SNMP (empty string if no SNMP agent available); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

upsSnmpCommunity 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.7
UPS SNMP community name (empty string if no SNMP agent available); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

upsHttpPort 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.8
UPS HTTP interface port; specifies the TCP port number for accessing the UPS management interface via HTTP (0 if no HTTP server available); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

managementTimeZone 1.3.6.1.4.1.211.1.31.1.1.1.3.6
Management node timezone (e.g. '2004-9-22 12:15:18+09:00')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

serverTable 1.3.6.1.4.1.211.1.31.1.1.1.4.1
Table containing information about the available servers
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Servers

servers 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Servers  

srvUnitId 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

srvPhysicalMemory 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.2
Size of physical main memory installed (MBytes); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

srvLastBootResult 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.3
Result of last system boot; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), os-boot-successful(2), diagnostic-boot-successful(3), no-boot-cpu(4), no-bootable-media(5), os-failed-load(6), diagnostic-boot-failed(7), hardware-failure(8)  

srvCurrentBootStatus 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.4
Status of the current boot unknown(1)' returns; during the Power-on->POST and the shutdown->Power-off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), off(2), no-boot-cpu(3), self-test(4), setup(5), os-boot(6), diagnostic-boot(7), os-running(8), diagnostic-running(9), os-shutdown(10), diagnostic-shutdown(11), reset(12), panic(13), check-stop(14), dumping(15), halt(16), xpar-firm-running(17)  

srvShutdownCommand 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.5
Shutdown the server and switch off or reset; a delay (see object below) can be defined before the command is being executed; on reading that value you get the currently pending or executing command value; argument tells what kind of action: power-on: switch power on power-off: switch power off power-cycle: switch power off and switch power on again. shutdown-and-off: execute a shutdown then power off shutdown-and-reset: execute a shutdown then reset shutdown-and-power-cycle: execute a shutdown then power off and on again raise-nmi: raise an NMI (normally causes debugger to start) The value unknown(1) cannot be set; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), power-off(2), power-on(3), power-cycle(4), shutdown-and-off(5), shutdown-and-reset(6), shutdown-and-power-cycle(7), raise-nmi(8), abort-pending-command(9), reset(10)  

srvShutdownDelay 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.6
Delay time (seconds) the agent waits before executing the shutdown command (see previous command). 0 = immediate action; no delay -1 = unknown (delay not supported) The value unknown(-1) cannot be set; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

srvUUID 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.7
Universal Unique ID (UUID) number - this is a world wide unique ID number of the server. Can be used for identifying a server. The format is like this: 157E465A-A4AC-D711-A847-DD85CECD12EC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

srvPhysicalMemoryOs 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.8
Size of physical main memory available to the operating system (MBytes). This value is similar to sc2srvPhysicalMemory'; but may be less if the system has mirror or hot spare memory modules; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

srvTpmMode 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.9
Trusted Platform Module(TPM) setting.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

srvManagementIP 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.10
BMC management address (e.g. 192.168.0.150)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitPowerOnOffTable 1.3.6.1.4.1.211.1.31.1.1.1.4.2
Unit power-on and -off information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UnitPowerOnOff

unitPowerOnOff 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UnitPowerOnOff  

ooUnitId 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

powerOnOffStatus 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.2
Current power on/off status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

lastPowerOffSource 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.3
Reason why the system was switched off last time; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), swoff-command(2), power-button(3), ac-fail(4), clock(5), fan-fail(6), temperature-critical(7), temperature-damage(8), power-supply-failure(9), watchdog(10), remote-off(11), hardware-fail(12), peripheral-bus-error(13), cpu-error(14), nmi(20), hardware-reset(23), warmstart(24), reset-button(25), ac-fail-reboot(26), keyboard(29), remote-manager(31), remote-manager-reset(32), power-limiting(35), mmb-continuous-operation(36), watchdog-power-cycle(37), firmware-restart(242), housing-opened(243)  

lastPowerOnSource 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.4
Source the system was switched on from; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), swoff-command(2), power-button(3), ac-fail(4), clock(5), fan-fail(6), temperature-critical(7), temperature-damage(8), power-supply-failure(9), watchdog(10), remote-on(11), hardware-fail(12), peripheral-bus-error(13), cpu-error(14), nmi(20), hardware-reset(23), warmstart(24), reset-button(25), ac-fail-reboot(26), mgmt-processor-fail(27), pci-pme(28), keyboard(29), chipcard-reader(30), remote-manager(31), remote-manager-reset(32), power-cycle(33), firmware-restart(242), housing-opened(243)  

lastPowerOnTime 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.5
Time and Date the system was booted (seconds since 1/1/1970; -1 = unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

powerOnCounts 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.6
Tells how often the server was switched on in its life (-1 = unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

powerOnDuration 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.7
Tells how long the system has stayed ON in its life (in hours; -1 = unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

powerOffDuration 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.8
Tells how long the system has stayed OFF in its life (in hours; -1 = unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

powerFailRecovery 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.9
Action on AC power recovery after AC has failed. not-available(2) : function not available; behavior is hardware-defined. as-before(3) : server gets the same power state as before the AC fail. remain-off(4) : server remains off on power resume. switch-on(5) : server is always switched on on power resume. schedule-sync(6) : server synchronizes the power state with the schedule setting.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), as-before(3), remain-off(4), switch-on(5), schedule-sync(6)  

powerCommand 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.10
Switch the unit on or off; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switch power off and switch power on again. The value unknown(1) cannot be set; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3), power-cycle(4)  

powerSupplyRedundancy 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.11
Specifies whether the power supply system contains redundant power supplies: 0 : no redundant power supplies available 1 : redundant power supplies available
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

performanceTable 1.3.6.1.4.1.211.1.31.1.1.1.4.3
Server performance and utilization information; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Performance

performance 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Performance  

perfUnitId 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1.1
Unit identifier (index; 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfNr 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1.2
Server performance entry number (index; 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfType 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1.3
Server performance object type (description see below); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cpu(1), cpu-pverall(2), pci-load(3), pci-efficiency(4), pci-transfer(5), memory-physical(6), memory-total(7), memory-percent(8)  

performanceValue 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1.4
Server performance value (value interpretation depending on type):; Not supported. cpu: Load of a single CPU in percent cpu-overall: Overall CPU load in percent pci-load: PCI bus load in percent pci-efficiency: PCI bus efficiency in percent (100% is optimum) pci-transfer: PCI bus transfer rate in MBytes/sec. memory-physical: Physical memory usage in MBytes memory-total: Total memory usage (physical + virtual) in MBytes memory-percent: Physical memory usage in percent
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

performanceName 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1.5
Name (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

timerOnOffTable 1.3.6.1.4.1.211.1.31.1.1.1.4.4
Power on/off timer table; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TimerOnOff

timerOnOff 1.3.6.1.4.1.211.1.31.1.1.1.4.4.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TimerOnOff  

tooUnitId 1.3.6.1.4.1.211.1.31.1.1.1.4.4.1.1
Unit identifier (index: 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tooDayOfWeek 1.3.6.1.4.1.211.1.31.1.1.1.4.4.1.2
Day of the week the times should act upon (index); 1=Sunday 2=Monday... ; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

onTime 1.3.6.1.4.1.211.1.31.1.1.1.4.4.1.3
Time the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled; no on time). Only values -1 and 0..1439 are allowed; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

offTime 1.3.6.1.4.1.211.1.31.1.1.1.4.4.1.4
Time the system should be switched off (by the real-time clock of software; in minutes since midnight; -1 = disabled; no on time). Only values -1 and 0..1439 are allowed; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

powerMonitoringTable 1.3.6.1.4.1.211.1.31.1.1.1.4.5
Power monitoring table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PowerMonitoring

powerMonitoring 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PowerMonitoring  

pmUnitId 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pmCurrentPowerMonitoringAvailable 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.2
Power monitoring and control available on this server: true: Power monitoring and power control is available false: Power monitoring and power control is not available
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

pmCurrentPowerMonitoringEnabled 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.3
Power monitoring enable value: true: Power monitoring and data gathering is enabled false: Power monitoring and data gathering is disabled or not available
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

pmNominalPowerConsumption 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.4
Nominal (maximum) value of the system's power consumption (in Watts; -1 if value not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pmCurrentPowerConsumption 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.5
Current value of the system's power consumption (in Watts; 4294967295(0xffffffff) if value not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

pmCurrentPowerControl 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.6
Power mode control value; Not supported. disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption scheduled: The baseboard management controller controls power consumption by schedule
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), best-performance(3), minimum-power(4), automatic(5), scheduled(6), limited(7)  

pmPowerLimitThreshold 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.8
Maximum limit value of the system's power consumption (in Watts; -1 if value not available; only valid if limiting enabled)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pmPowerControlMode 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.11
Configured power control mode value: disabled: The management controller does not control the power saving behaviour best-performance: The management controller gives best performance to the system (power consumption may be increased) minimum-power: The management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The management controller automatically controls power consumption between good performance and low power consumption scheduled: The management controller controls power consumption by schedule limited: The management controller controls power consumption by power limit low-noise: The management controller controls the power to ensure running
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), best-performance(3), minimum-power(4), automatic(5), scheduled(6), limited(7), low-noise(8)  

pmPowerDisplayUnit 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.12
Configurd unit for the display of power consumption values: Watt: Power consumption values are displayed in Watts Btu/h: Power consumption values are displyed in Btu
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), watt(2), btu(3)  

utilizationHistoryTable 1.3.6.1.4.1.211.1.31.1.1.1.4.6
Utilization history table (for power consumption); table only contains existing values (no values for non-existing values); Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UtilizationHistory

utilizationHistory 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UtilizationHistory  

uthUnitId 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.1
Unit identifier (index; 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

uthEntity 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.2
Utilization value entity; describes what kind of value to be requested; Not supported. powerConsumptionDay: power consumption values of the last 24 hours; one value (Watts) per minute powerConsumptionMonth: power consumption values of the last month; one value (Watts) per hour powerConsumptionYear: power consumption values of the last year; one value (Watts) per day
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER powerConsumptionDay(1), powerConsumptionMonth(2), powerConsumptionYear(3)  

uthTimeStamp 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.3
Time stamp of the currenty history entry (time_t = seconds since 1/1/1970; 0:00 AM); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

uthHardwareUUID 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.4
UUID of the hardware instance that delivered the value (from object sc2srvUUID); may change if an installation is migrated to another hardware (e.g. in blade environments); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

uthAverageValue 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.5
Average value (in Watts) within the monitored time period (minute; hour; day); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

uthMinValue 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.6
Minimum (lowest) value within the monitored time period; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

uthMaxValue 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.7
Maximum (highest) value within the monitored time period; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

powerSourceInformationTable 1.3.6.1.4.1.211.1.31.1.1.1.4.7
Power source information table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PowerSourceInformation

powerSourceInformation 1.3.6.1.4.1.211.1.31.1.1.1.4.7.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PowerSourceInformation  

psiUnitId 1.3.6.1.4.1.211.1.31.1.1.1.4.7.1.1
Unit identifier (index; 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

psiPowerSourceType 1.3.6.1.4.1.211.1.31.1.1.1.4.7.1.2
System input power source type (e.g. 'AC'; 'DC')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

psiPowerSourcePhase 1.3.6.1.4.1.211.1.31.1.1.1.4.7.1.3
System input phase of power source.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), single-phase(2), three-phase(3)  

psiPowerSourceVoltage 1.3.6.1.4.1.211.1.31.1.1.1.4.7.1.4
System nominal input voltage of power source (in Volts; -1 if value not available).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

temperatureSensorTable 1.3.6.1.4.1.211.1.31.1.1.1.5.1
Temperature sensors
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TemperatureSensors

temperatureSensors 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TemperatureSensors  

tempUnitId 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tempSensorNr 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.2
Temperature sensor number (index: 0..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tempSensorDesignation 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.3
Temperature sensor designation (e.g. SB#0-CPU#A0 Temp.)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

tempSensorIdentifier 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.4
Temperature sensor identification string (e.g. TEMP-RSB1); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

tempSensorStatus 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.5
Status of the temperature sensor Status mapping. SEL level MIB Value Warning temperature-warning(6) Error temperature-critical(7) Error failed(5)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), ok(3), failed(5), temperature-warning(6), temperature-critical(7)  

tempCurrentTemperature 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.6
Current temperature at this sensor (degrees Celsius). This object returns 0; if the agent can not get the value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tempWarningLevel 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.7
Maximum temperature - warning level (degrees Celsius)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tempCriticalLevel 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.8
Maximum temperature - critical level (degrees Celsius). system shutdown may occur if this level is exceeded.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tempCriticalReaction 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.9
Reaction if temperature exceeds the critical level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), continue(2), shutdown-and-poweroff(3)  

fanTable 1.3.6.1.4.1.211.1.31.1.1.1.5.2
Fans
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Fans

fans 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Fans  

fanUnitId 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fanNr 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.2
Fan number (index: 0..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fanDesignation 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.3
Fan designation (e.g. FAN-TRAY#00-Fan#00-1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fanIdentifier 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.4
Fan identification string (e.g. FAN-1-POWERSUPPLY); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fanStatus 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.5
Status of the fan Status mapping. SEL level MIB Value Error failed(5)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), ok(3), failed(4), prefailed-predicted(5), redundant-fan-failed(6), not-manageable(7), not-present(8)  

fanCurrentSpeed 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.6
Current fan speed (revolutions per minute). This object returns 0; if the agent can not get the value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fanQuality 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.7
Quality of fan (in percent of nominal speed - measured at full speed); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fanFailReaction 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.8
Reaction if the fan fails.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), continue(2), shutdown-and-poweroff(3)  

fanFailShutdownDelay 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.9
Delay time (in seconds) when shutdown should commit on fan fail (if shutdown-and-off is configured; 0 = immediately -1 = unknown; cannot be set); Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

airflowTable 1.3.6.1.4.1.211.1.31.1.1.1.5.3
Exhaust airflow volume table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Airflow

airflow 1.3.6.1.4.1.211.1.31.1.1.1.5.3.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Airflow  

afUnitId 1.3.6.1.4.1.211.1.31.1.1.1.5.3.1.1
Unit identifier (index; 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

afExhaustAirflowVolume 1.3.6.1.4.1.211.1.31.1.1.1.5.3.1.2
System exhaust airflow volume ('-1' if value not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

afExhaustAirflowVolumeUnit 1.3.6.1.4.1.211.1.31.1.1.1.5.3.1.3
System exhaust airflow volume unit (e.g. 'cbm/h'; 'ccm/min'; ...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemBoardTable 1.3.6.1.4.1.211.1.31.1.1.1.6.1
System board (main board) information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SystemBoard

systemBoard 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SystemBoard  

sbUnitId 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

systemBoardModelName 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.2
Model name (e.g. 'System Board')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemBoardProductNumber 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.3
Product number (may be identical to ModelName)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemBoardRevision 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.4
Revision string (e.g. 'WGS1 GS3')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemBoardSerialNumber 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.5
Serial number (not available for all boards)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

powerSupplyTable 1.3.6.1.4.1.211.1.31.1.1.1.6.2
Power supplies
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PowerSupply

powerSupply 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PowerSupply  

psUnitId 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

psPowerSupplyNr 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.2
Power supply (bay) number (index: 0..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

powerSupplyDesignation 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.3
Power supply designation (e.g. PWRSYS#1-FEP#0)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

powerSupplyIdentifier 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.4
Power supply identification string (e.g. PS1); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

powerSupplyStatus 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.5
Power supply status Status mapping. SEL level MIB Value Warning ac-fail(5) Warning predictive-fail(9) Error failed(4) Error not-manageable(8)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), ok(3), failed(4), ac-fail(5), dc-fail(6), critical-temperature(7), not-manageable(8), predictive-fail(9)  

psPowerSupplyLoad 1.3.6.1.4.1.211.1.31.1.1.1.2.1.6
Actual power supply output load in Watts (0 = not available); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

voltageTable 1.3.6.1.4.1.211.1.31.1.1.1.6.3
Voltages - all voltage values are in 1/100th Volts; a value of 330 means 3.30 Volts (0xffffffff = unknown)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Voltages

voltages 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Voltages  

voUnitId 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

voSensorNr 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.2
Voltage sensor number (index: 0..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

voltageDesignation 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.3
Voltage designation string (e.g. SB#1-+5V#1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

voltageStatus 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.4
Voltage status Status mapping. SEL level MIB Value Warning low-warning(7) Warning high-warning(8) Error too-low(4) Error too-high(5)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), ok(3), too-low(4), too-high(5), sensor-failed(6), low-warning(7), high-warning(8)  

voltageCurrentValue 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.5
Voltage current value. This object returns 0; if the agent can not get the value.(1/100V)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

voltageNominalValue 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.6
Voltage nominal value; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

voltageMinimumLevel 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.7
Voltage minimum level (1/100V)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

voltageMaximumLevel 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.8
Voltage maximum level (1/100V)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

voltageCurrentLoad 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.9
Current output load on this voltage line. in percent of the maximum load (0xffffffff = unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

cpuTable 1.3.6.1.4.1.211.1.31.1.1.1.6.4
CPU description table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cpus

cpus 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cpus  

cpuUnitId 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuNr 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.2
CPU (socket) number (index: 0..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuDesignation 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.3
CPU designation (e.g. SB#0-CPU#A0)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpuStatus 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.4
CPU status Status mapping. SEL level MIB Value Warning disabled(4) Warning prefailed-warning(8) Error failed(6)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), ok(3), disabled(4), error(5), failed(6), missing-termination(7), prefailed-warning(8)  

cpuModelName 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.5
CPU model name (e.g. Itanium2 Processor)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpuManufacturer 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.6
CPU manufacturer name (e.g. Intel); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpuStep 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.7
CPU step / revision
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpuCurrentSpeed 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.8
CPU speed (frequency in MHz)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuNumberLogicals 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.9
Number of (physically available) logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical CPUs of a hyper-threading CPU; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuCacheL1Size 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.10
Size of first level cache (in kBytes; -1 if unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuCacheL2Size 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.11
Size of second level cache (in kBytes; -1 if unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuCacheL3Size 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.12
Size of third level cache (in kBytes; -1 if unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuNumberCores 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.13
Number of (physically available) cores within one physical CPU (for multi-core CPUs; platform dependent)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuFamily 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.14
CPU family code. This enumerated value is specified by the DMTF SMBIOS specification (processor information; type 4); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuEnabledCores 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.15
Number of effectively enabled cores within one physical CPU (for multi-core CPUs; 0 if unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memoryModuleTable 1.3.6.1.4.1.211.1.31.1.1.1.6.5
Main memory module table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MemoryModules

memoryModules 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MemoryModules  

memUnitId 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleNr 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.2
Memory module (socket) number (index: 0..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleDesignation 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.3
Memory module designation (e.g. SB#0-DIMM#0A0)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

memModuleStatus 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.4
Memory module status Status mapping. SEL level MIB Value Warning failed-disabled(4) Warning warning(7) Error error(5) Error configuration-error(9)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), ok(3), failed-disabled(4), error(5), warning(7), hot-spare(8), configuration-error(9)  

memModuleBank 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.5
Memory module bank number (-1 if unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleCapacity 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.6
Memory module size (capacity in MBytes; -1 if unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleStartAddress 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.7
Memory module start address (in MBytes; -1 if unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleForm 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.8
Memory module form (SIMM DIMM ...); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

memModuleType 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.9
Memory module type (SDRAM DDRAM DDR2 DDR3 ...); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

memModuleCorrErrors 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.10
Number of memory module correctable errors (-1 if unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

memModuleUncorrErrors 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.11
Number of memory module uncorrectable errors (-1 if unknown); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

memModuleApproved 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.12
Memory module approved for this machine; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), no(2), yes(3)  

memModuleConfiguration 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.13
Memory module configuration; Not supported. unknown(1): Module configuration could not be evaluated normal(2): Module is in normal non-redundant configuration or slot is empty disabled(3): Module is disabled (manually through BIOS setup) hotSpare(4): Module is a hot-spare (standby) module; which will be used as a run-time-replacement for failed modules mirror(5): Module is part of a mirror configuration raid(6): Module is part of a RAID configuration notUsable(7): Module is not usable in the actual configuration because of architectural restrictions This object replaces the previous redundancy status values hot-spare and mirror in sc2memModuleStatus.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), normal(2), disabled(3), hotSpare(4), mirror(5), raid(6), notUsable(7)  

memModuleFrequency 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.14
Memory module actual front side bus frequency (in MHz; -1 if unknown). This value is based on the BIOS settings; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleMaxFrequency 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.15
Memory module maximum front side bus frequency (in MHz; -1 if unknown). This value is based on memory module SPD data; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleVoltInterface 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.16
Memory module interface voltage interface description; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpuMultithreadEnable 1.3.6.1.4.1.211.1.31.1.1.1.6.6
Multithreading of CPU enabled; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), enabled(3)  

componentPowerConsumptionTable 1.3.6.1.4.1.211.1.31.1.1.1.6.7
Table of component power consumption data; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ComponentPowerConsumption

componentPowerConsumption 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ComponentPowerConsumption  

cpcUnitId 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1.1
Unit identifier (index; 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpcComponentClass 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1.2
Component class enumeration (based on IPMI v1.0 entity ID); Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER processor(3), disk(4), memory-unit(8), processor-module(9), chassis(23), sub-chassis(24), disk-bay(26), cooling-device(29), cooling-unit(30), memory-device(32)  

cpcComponentIndex 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1.3
Component index within class (1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpcDesignation 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1.4
Component designation; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpcCurrentValue 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1.5
Current component power consumption in Watts; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trustedPlatformModuleTable 1.3.6.1.4.1.211.1.31.1.1.1.6.8
Trusted Platform Module (TPM) status information (see corresponding TPM specification for detailed description of these states)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrustedPlatformModule

trustedPlatformModule 1.3.6.1.4.1.211.1.31.1.1.1.6.8.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TrustedPlatformModule  

tpmUnitId 1.3.6.1.4.1.211.1.31.1.1.1.6.8.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tpmHardwareAvailable 1.3.6.1.4.1.211.1.31.1.1.1.6.8.2
TPM hardware is available ('unknown' if hardware availability cannot be detected; no interface found)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

tpmBiosEnabled 1.3.6.1.4.1.211.1.31.1.1.1.6.8.3
TPM hardware is enabled by BIOS ('unknown' if hardware is not available; a reboot is required to change this value)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

tpmEnabled 1.3.6.1.4.1.211.1.31.1.1.1.6.8.4
TPM is enabled (by software; cannot take ownership if disabled; 'unknown' if hardware is not available or disabled)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

tpmActivated 1.3.6.1.4.1.211.1.31.1.1.1.6.8.5
TPM is activated (by software; 'unknown' if hardware is not available or disabled)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

tpmOwnership 1.3.6.1.4.1.211.1.31.1.1.1.6.8.6
TPM ownership is established (valid endorsement key is existing; 'unknown' if hardware is not available or disabled)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

messageLogTable 1.3.6.1.4.1.211.1.31.1.1.1.7.1
Error and event message handling; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MessageLogs

messageLogs 1.3.6.1.4.1.211.1.31.1.1.1.7.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MessageLogs  

msgUnitId 1.3.6.1.4.1.211.1.31.1.1.1.7.1.1.1
Unit identifier (index: 1..n); Not supported..
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

msgLogEntryNr 1.3.6.1.4.1.211.1.31.1.1.1.7.1.1.2
Message log entry number (index: 0..n); Not supported..
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

msgLogEntryData 1.3.6.1.4.1.211.1.31.1.1.1.7.1.1.3
Message log entry data (binary; one message per table entry); Not supported..
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

watchdogTable 1.3.6.1.4.1.211.1.31.1.1.1.7.2
Watchdogs
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Watchdogs

watchdogs 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Watchdogs  

wdUnitId 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

watchdogType 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.2
Watchdog type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), hardware(2), software(3), bios(4), boot(5), management-controller(6), remote-management-controller(7), management-soft(8)  

watchdogStatus 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.3
Watchdog status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3), not-available(4)  

watchdogEnable 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.4
Enable/disable watchdog
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3)  

watchdogTime 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.5
Watchdog timeout period in seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

watchdogAction 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.6
Watchdog timeout action
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), continue(2), reboot(3), nmi(4), power-cycle(5), power-down(6), hardware-reset(7)  

recoverySettingTable 1.3.6.1.4.1.211.1.31.1.1.1.7.3
ASR&R (Automatic server recovery and restart) settings; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RecoverySettings

recoverySettings 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RecoverySettings  

asrUnitId 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.1
Unit identifier (index: 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

asrNrRebootRetries 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.2
Current number of retries to reboot/restart the server when a failure shutdown (and power-off) had occurred. After this number of retries the action defined in 'sc2asrRebootFailAction' will be executed (-1 = unknown; no retries). The value unknown(1) cannot be set; a SET will deliver 'badValue'; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

asrDefaultRebootRetries 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.3
Default number of retries for server failure reboot. The previous object sc2asrNrRebootRetries will be set to this value after the server is working properly for a certain amount of time; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

asrNextBootSource 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.4
Source medium to boot from (next time): operating-system: boot from floppy or hard disk diag-system: boot from alternate diagnostic system (only for SCSI systems; load diagnostic system from alternate IDE disk). remote-disk: boot from remote network disk The value unknown(1) cannot be set; a SET will deliver 'badValue'; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), operating-system(2), reserved(3), diag-system(4), remote-disk(5)  

asrRebootFailAction 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.5
Specifies the action after a specified number of failed reboot retries (the object 'sc2asrNrRebootRetries' has reached zero).The value no-diag-system(4) means that a diagnostic system is not available; no other value can be set. The values unknown(1) and reserved(3) cannot be set; a SET will deliver 'badValue'; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), switch-off(2), boot-diag-system(3), no-diag-system(4)  

asrRestartDelay 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.6
Delay (in minutes) when the system should be automatically switched on again (by real-time clock) after an error power-off. Setting this value to zero means immediate restart (power-cycle only). You can disable automatic restart by setting the 'sc2asrRebootFailAction' to 'switch-off' and the 'sc2asrDefaultRebootRetries' to zero; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

asrPostErrorHalt 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.7
Describes what to do when a POST error has occurred (halt on any error; no halt on any error...). The values unknown(1) and other(9) cannot be set; a SET will deliver 'badValue'; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), halt-on-any-error(2), no-halt-on-any-error(3), other(4)  

messageTextLogTable 1.3.6.1.4.1.211.1.31.1.1.1.7.4
Error and event message handling; reported as text strings; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MessageTextLogs

messageTextLogs 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MessageTextLogs  

msgTextLogUnitId 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.1
Unit identifier (index: 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

msgTextLogLanguage 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.2
Message log entry language (index; Windows language code); Not supported. e.g. 1031; 1033 for German; English (default; always available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

msgTextLogSeqNr 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.3
Message log entry sequence number (index; 0..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

msgTextLogTimestamp 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.4
Message log entry time stamp (time_t = seconds since 1/1/1970; 0:00 AM); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

msgTextLogMessage 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.5
Message log entry message string (multi-byte string; multi-language; not every language may be implemented); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

msgTextLogErrorCode 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.6
Message log entry error code; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

msgTextLogSeverity 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.7
Message log entry severity; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER informational(1), minor(2), major(3), critical(4)  

msgTextLogCSSComponent 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.8
Component which caused the log message may be replaced by the customer (CSS=Customer Self Service); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

messageLogActionHintTable 1.3.6.1.4.1.211.1.31.1.1.1.7.5
Action text strings for error and event messages; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MessageLogActionHints

messageLogActionHints 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MessageLogActionHints  

mlaLanguage 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1.1
Action text language (index; Windows language code) e.g. 1031; 1033 for German; English; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mlaErrorCode 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1.2
Action text error code (index); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mlaType 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1.3
Message log entry severity; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER summary(1), cause(2), resolution(3)  

mlaIndex 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1.4
Action text entry string index (index; 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mlaMessage 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1.5
Action message string; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

agentStatus 1.3.6.1.4.1.211.1.31.1.1.1.8.1
Overall status of all monitored components in this agent ok(1): all subsystems and components working properly; no failure degraded(2): at least one component has a problem; system may still work properly error(3): severe problem; system will not work properly failed(4): one or more managed components have failed unknown(5): none of the subsystems had a valid status (e.g. during initialization)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), degraded(2), error(3), failed(4), unknown(5)  

statusComponentTable 1.3.6.1.4.1.211.1.31.1.1.1.8.2
Table with status values of the components in this agent. The table summarizes all instances of one component to one status value.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StatusComponents

statusComponents 1.3.6.1.4.1.211.1.31.1.1.1.8.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  StatusComponents  

csUnitId 1.3.6.1.4.1.211.1.31.1.1.1.8.2.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

csType 1.3.6.1.4.1.211.1.31.1.1.1.8.2.1.2
Component status type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER system-boot(1), power(2), temperatures(3), fans(4), power-supplies(5), voltages(6), cpus(7), memory-modules(8), total(9), fan-redundancy(10), power-supply-redundancy(11)  

componentStatusValue 1.3.6.1.4.1.211.1.31.1.1.1.8.2.1.3
Component status value (for description of status values see previous object) Status mapping. SEL level MIB Value Warning degraded(2) Warning failed(4) Error error(5)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), degraded(2), error(3), failed(4), unknown(5)  

componentStatusSensorTable 1.3.6.1.4.1.211.1.31.1.1.1.8.3
This table contains the component status sensor table of the BMC (baseboard management controller). Additionally it also holds the CSS (Customer Self Service) information; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ComponentStatusSensors

componentStatusSensors 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ComponentStatusSensors  

cssUnitId 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.1
Unit identifier (index: 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cssSensorNumber 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.2
BMC component status sensor number (index; 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cssSensorDesignation 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.3
Component status sensor designation string; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cssSensorDevice 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.4
Name of device (entity) the component status sensor belongs to; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cssSensorDeviceInstance 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.5
Instance number of device (entity) the component status sensor belongs to; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cssSensorPhysicalLed 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.6
If set; component has a physical status LED showing the sensor status; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

cssSensorCssComponent 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.7
If set; component may be replaced by the customer (CSS component); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

cssSensorStatus 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.8
Status returned by the component status sensor; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), identify(3), prefailure-warning(4), failure(5), not-present(6)  

cssComponentServicePartId 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.9
Spare part number of the replaceable component; used to create a link to the spare part list on the service's spare part catalogue. This usually is the component's designation string; with blanks substituted by underscores; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cssTableSize 1.3.6.1.4.1.211.1.31.1.1.1.8.4
Number of entries in the component status sensor table; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

maintenanceObjectTable 1.3.6.1.4.1.211.1.31.1.1.1.9.1
Table containing some other maintenance objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MaintenanceObjects

maintenanceObjects 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MaintenanceObjects  

mtUnitId 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1.1
Unit identifier (index: 1..n).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

errorCounterStartTime 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1.2
Memory module error counter start time (seconds since 1/1/1970; -1 if unknown). This is the time when the error counters were started or reset last time; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sendTestTrap 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1.3
Send a test trap (test alarm) to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Initiate test trap sending by writing a non-zero value. Reading this object just returns the value 0; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

addTrapDestination 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1.4
Add the specified IP address (of the management station) to the trap destination list of this server. That client will become an alarm receiver for traps of this server; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mtMaintenanceStatus 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1.5
maitenance status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

firmwareVersionTable 1.3.6.1.4.1.211.1.31.1.1.1.9.2
Controller firmware version table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FirmwareVersions

firmwareVersions 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FirmwareVersions  

fwUnitId 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1.1
Unit identifier (index: 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fwType 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1.2
Controller/firmware type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bios(1), management-controller(2), remote-management-controller(3), pal(4), sal(5), efi(6), baseboard-management-controller(7), gswb-offline0(8), gswb-offline1(9), gswb-online0(10), gswb-online1(11), total(20)  

fwModelName 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1.3
Controller/firmware model name (e.g. 'Copernicus'...) TOTAL' shows all firmware version in system (including BIOS; BMC; MMB).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fwVersion 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1.4
Controller/firmware version string (e.g. '3.81.02')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fwLocation 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1.5
BMM physical number of controller/firmware on IOU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

deployInfoTable 1.3.6.1.4.1.211.1.31.1.1.1.10.1
Table with data of deployment information; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DeployInfo

deployInfo 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DeployInfo  

dplInfoUnitId 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.1
Unit identifier (index: 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

deployInfoChassisId 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.2
Chassis serial number; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

deployInfoMacAddr1 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.3
MAC address 1; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

deployInfoMacAddr2 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.4
MAC address 2; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

deployInfoMacAddr3 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.5
MAC address 3; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

deployInfoMacAddr4 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.6
MAC address 4; Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

deployInfoIpAddr1 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.7
IP address 1; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoIpAddr2 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.8
IP address 2; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoIpAddr3 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.9
IP address 3; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoIpAddr4 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.10
IP address 4; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoNetMask1 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.11
IP subnet mask 1; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoNetMask2 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.12
IP subnet mask 2; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoNetMask3 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.13
IP subnet mask 3; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoNetMask4 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.14
IP subnet mask 4; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoGateway1 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.15
IP gateway 1; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoGateway2 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.16
IP gateway 2; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoGateway3 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.17
IP gateway 3; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoGateway4 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.18
IP gateway 4; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deployInfoHostname 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.19
Host name; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

deployInfoMasterImageReference 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.20
URL in UNC notification (but in ASCII) to remote image file (with the extensions of *.img; *.cfg; *.txt); Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

deployInfoStatusOfBlade 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.21
Status of this server: power-down(2): waiting for boot standby(3): power management mode system-boot-failure(4): system boot failure bios-setup(5): BIOS setup or boot phase booting(6): ACPI OS currently booting ; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), power-down(2), standby(3), system-boot-failure(4), bios-setup(5), booting(6)  

deployInfoLanStatusOfSlot 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.22
Defines whether the IP-LAN definitions are valid or not; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), false(2), true(3)  

deployInfoAutomaticRecovery 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.23
Defines if this server blade should be provided automatic recovery; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), false(2), true(3)  

deployInfoStatusOfCloning 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.24
Status of current cloning process; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), not-cloned(2), cloning(3), cloned(4)  

deployInfoBootMode 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.25
Boot mode of the server for remote deployment: normal(2): boot from standard disk subsystem pxeBiosSetup(3): boot from PXE according to BIOS setup settings (for OEM systems) pxeLanx(y): boot from PXE LAN interface x (0..3) ; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), normal(2), pxeBiosSetup(3), pxeLan0(4), pxeLan1(5), pxeLan2(6), pxeLan3(7)  

oemDeployInfoTable 1.3.6.1.4.1.211.1.31.1.1.1.10.2
Table with data of server OEM information; Not supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OemDeployInfo

oemDeployInfo 1.3.6.1.4.1.211.1.31.1.1.1.10.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OemDeployInfo  

odplInfoUnitId 1.3.6.1.4.1.211.1.31.1.1.1.10.2.1.1
Unit identifier (index: 1..n); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

odplParamId 1.3.6.1.4.1.211.1.31.1.1.1.10.2.1.2
OEM parameter ID (index: 1..10); Not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oemDeployInfoParamData 1.3.6.1.4.1.211.1.31.1.1.1.10.2.1.3
OEM parameter data; Not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

deployLanInterfaceTable 1.3.6.1.4.1.211.1.31.1.1.1.10.3
Table with system LAN interfaces information: This table lists all real LAN interfaces in same physical order as the BIOS uses it for PXE boot. Only on-board interfaces are listed; no virtual interfaces.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DeployLanInterfaces

deployLanInterfaces 1.3.6.1.4.1.211.1.31.1.1.1.10.3.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DeployLanInterfaces  

dplLanUnitId 1.3.6.1.4.1.211.1.31.1.1.1.10.3.1.1
Unit identifier (index; 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dplLanInterfaceNr 1.3.6.1.4.1.211.1.31.1.1.1.10.3.1.2
LAN interface number (index; 0..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dplLanMacAddress 1.3.6.1.4.1.211.1.31.1.1.1.10.3.1.3
LAN interface hardware (MAC) address; ff:ff:ff:ff:ff:ff if value not available
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress