MITEL-MN3100-CALL-CONTROL-MIB

File: MITEL-MN3100-CALL-CONTROL-MIB.mib (5067 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF

Imported symbols

MODULE-IDENTITY OBJECT-TYPE enterprises
Integer32 Counter32 NOTIFICATION-TYPE
NOTIFICATION-GROUP

Defined Types

MitelCallCtrlFaultEntry  
SEQUENCE    
  mitelCallCtrlFaultTblIndex Integer32
  mitelCallCtrlFaultId INTEGER
  mitelCallCtrlFaultStatus INTEGER
  mitelCallCtrlFaultOccur Counter32

Defined Values

mitelCallControl 1.3.6.1.4.1.1027.4.9
The MITEL Call CONTROL MIB module.
MODULE-IDENTITY    

mitel 1.3.6.1.4.1.1027
OBJECT IDENTIFIER    

mitelProprietary 1.3.6.1.4.1.1027.4
OBJECT IDENTIFIER    

mitelIdentification 1.3.6.1.4.1.1027.1
OBJECT IDENTIFIER    

mitelIdCallServers 1.3.6.1.4.1.1027.1.2
OBJECT IDENTIFIER    

mitelIdCsIpera1000 1.3.6.1.4.1.1027.1.2.4
OBJECT IDENTIFIER    

mitelCallCtrlFaultTable 1.3.6.1.4.1.1027.4.9.1
The Call Control Fault table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MitelCallCtrlFaultEntry

mitelCallCtrlFaultEntry 1.3.6.1.4.1.1027.4.9.1.1
An entry in the mitelCallCtrlFaultTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  MitelCallCtrlFaultEntry  

mitelCallCtrlFaultTblIndex 1.3.6.1.4.1.1027.4.9.1.1.1
The index of the fault table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mitelCallCtrlFaultId 1.3.6.1.4.1.1027.4.9.1.1.2
The mitelCallCtrlFaultId indicates the id of the fault.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER mitelCallCtrlFailedSeizeLine(1), mitelCallCtrlDdiMappingError(2)  

mitelCallCtrlFaultStatus 1.3.6.1.4.1.1027.4.9.1.1.3
The mitelCallCtrlFaultStatus indicates whether the fault is raised or cleared.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER set(1), clear(2), message(3)  

mitelCallCtrlFaultOccur 1.3.6.1.4.1.1027.4.9.1.1.4
The mitelCallCtrlFaultOccur indicates the occurence of the fault since the last system restart
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mitelIpera1000Notifications 1.3.6.1.4.1.1027.1.2.4.0
Call Server Ipera 1000 Notifications.
Status: current Access: read-only
NOTIFICATION-GROUP    

mitelCallCtrlFailedSeizeLineNotif 1.3.6.1.4.1.1027.1.2.4.0.406
The mitelMn3100CallCtrlFaultNotif trap indicates that the call control has failed to seize a line.
Status: current Access: read-only
NOTIFICATION-TYPE    

mitelCallCtrlDdiMappingErrorNotif 1.3.6.1.4.1.1027.1.2.4.0.407
The mitelCallCtrlDdiMappingErrorNotif trap indicates that a DDI mapping has failed.
Status: current Access: read-only
NOTIFICATION-TYPE