MG-SNMP-UPS-MIB

File: MG-SNMP-UPS-MIB.mib (91684 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
RFC-1215

Imported symbols

enterprises IpAddress TimeTicks
DisplayString OBJECT-TYPE TRAP-TYPE

Defined Types

UpsmgManagersEntry  
SEQUENCE    
  mgmanagerIndex INTEGER
  mgmanagerDeviceNumber INTEGER
  mgmanagerNMSType INTEGER
  mgmanagerCommType INTEGER
  mgmanagerDescr DisplayString
  mgmanagerAddress IpAddress
  mgmanagerCommunity DisplayString
  mgmanagerSeverityLevel INTEGER
  mgmanagerTrapAck INTEGER

UpsmgReceptaclesEntry  
SEQUENCE    
  mgreceptacleIndex INTEGER
  mgreceptacleLevel INTEGER
  mgreceptacleType DisplayString
  mgreceptacleIdent DisplayString
  mgreceptacleState INTEGER
  mgreceptacleReceptacle INTEGER
  mgreceptaclePowerCons INTEGER
  mgreceptacleOverload INTEGER
  mgreceptacleAutonomy INTEGER

UpsmgConfigDevicesEntry  
SEQUENCE    
  mgdeviceIndex INTEGER
  mgdeviceReceptacleNum INTEGER
  mgdeviceIdent DisplayString
  mgdeviceVaRating INTEGER
  mgdeviceSequenceOff INTEGER
  mgdeviceSequenceOn INTEGER
  mgdeviceShutdownDuration INTEGER
  mgdeviceBootUpDuration INTEGER

UpsmgConfigReceptaclesEntry  
SEQUENCE    
  mgreceptacleIndexb INTEGER
  mgreceptacleStateTurnOn INTEGER
  mgreceptacleStateMainReturn INTEGER
  mgreceptacleStateDischarge INTEGER
  mgreceptacleShutoffLevel INTEGER
  mgreceptacleShutoffTimer INTEGER
  mgreceptacleRestartLevel INTEGER
  mgreceptacleRestartDelay INTEGER
  mgreceptacleShutdownDuration INTEGER
  mgreceptacleBootUpDuration INTEGER

UpsmgConfigExtAlarmEntry  
SEQUENCE    
  mgextAlarmIndex INTEGER
  mgextAlarmUID DisplayString

UpsmgConfigControlDayEntry  
SEQUENCE    
  mgcontrolDayIndex INTEGER
  mgcontrolDayOn INTEGER
  mgcontrolDayOff INTEGER

UpsmgConfigEnvironmentEntry  
SEQUENCE    
  upsmgConfigSensorIndex INTEGER
  upsmgConfigSensorName DisplayString
  upsmgConfigTemperatureLow INTEGER
  upsmgConfigTemperatureHigh INTEGER
  upsmgConfigTemperatureHysteresis INTEGER
  upsmgConfigHumidityLow INTEGER
  upsmgConfigHumidityHigh INTEGER
  upsmgConfigHumidityHysteresis INTEGER
  upsmgConfigInput1Name DisplayString
  upsmgConfigInput1ClosedLabel DisplayString
  upsmgConfigInput1OpenLabel DisplayString
  upsmgConfigInput2Name DisplayString
  upsmgConfigInput2ClosedLabel DisplayString
  upsmgConfigInput2OpenLabel DisplayString

UpsmgInputPhaseEntry  
SEQUENCE    
  mginputIndex INTEGER
  mginputVoltage INTEGER
  mginputFrequency INTEGER
  mginputMinimumVoltage INTEGER
  mginputMaximumVoltage INTEGER
  mginputCurrent INTEGER

UpsmgOutputPhaseEntry  
SEQUENCE    
  mgoutputPhaseIndex INTEGER
  mgoutputVoltage INTEGER
  mgoutputFrequency INTEGER
  mgoutputLoadPerPhase INTEGER
  mgoutputCurrent INTEGER

UpsmgEnvironExtAlarmEntry  
SEQUENCE    
  mgalarmNum INTEGER
  mgalarmState INTEGER

UpsmgEnvironSensorEntry  
SEQUENCE    
  mgsensorNum INTEGER
  mgsensorTemp INTEGER
  mgsensorHumidity INTEGER

UpsmgEnvironmentSensorEntry  
SEQUENCE    
  upsmgEnvironmentIndex INTEGER
  upsmgEnvironmentComFailure INTEGER
  upsmgEnvironmentTemperature INTEGER
  upsmgEnvironmentTemperatureLow INTEGER
  upsmgEnvironmentTemperatureHigh INTEGER
  upsmgEnvironmentHumidity INTEGER
  upsmgEnvironmentHumidityLow INTEGER
  upsmgEnvironmentHumidityHigh INTEGER
  upsmgEnvironmentInput1State INTEGER
  upsmgEnvironmentInput2State INTEGER

UpsmgControlReceptaclesEntry  
SEQUENCE    
  mgreceptacleIndexc INTEGER
  mgreceptacleOnDelay INTEGER
  mgreceptacleOnCtrl INTEGER
  mgreceptacleOnStatus INTEGER
  mgreceptacleOffDelay INTEGER
  mgreceptacleOffCtrl INTEGER
  mgreceptacleOffStatus INTEGER
  mgreceptacleToggleDelay INTEGER
  mgreceptacleToggleCtrl INTEGER
  mgreceptacleToggleStatus INTEGER
  mgreceptacleToggleDuration INTEGER

Defined Values

merlinGerin 1.3.6.1.4.1.705
OBJECT IDENTIFIER    

upsmg 1.3.6.1.4.1.705.1
OBJECT IDENTIFIER    

upsmgIdent 1.3.6.1.4.1.705.1.1
OBJECT IDENTIFIER    

upsmgManagement 1.3.6.1.4.1.705.1.2
OBJECT IDENTIFIER    

upsmgReceptacle 1.3.6.1.4.1.705.1.3
OBJECT IDENTIFIER    

upsmgConfig 1.3.6.1.4.1.705.1.4
OBJECT IDENTIFIER    

upsmgBattery 1.3.6.1.4.1.705.1.5
OBJECT IDENTIFIER    

upsmgInput 1.3.6.1.4.1.705.1.6
OBJECT IDENTIFIER    

upsmgOutput 1.3.6.1.4.1.705.1.7
OBJECT IDENTIFIER    

upsmgEnviron 1.3.6.1.4.1.705.1.8
OBJECT IDENTIFIER    

upsmgControl 1.3.6.1.4.1.705.1.9
OBJECT IDENTIFIER    

upsmgTest 1.3.6.1.4.1.705.1.10
OBJECT IDENTIFIER    

upsmgTraps 1.3.6.1.4.1.705.1.11
OBJECT IDENTIFIER    

upsmgAgent 1.3.6.1.4.1.705.1.12
OBJECT IDENTIFIER    

upsmgRemote 1.3.6.1.4.1.705.1.13
OBJECT IDENTIFIER    

upsmgIdentFamilyName 1.3.6.1.4.1.705.1.1.1
The UPS family name (e.g. `PULSAR', `COMET', `GALAXY', ...).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgIdentModelName 1.3.6.1.4.1.705.1.1.2
The UPS model name (e.g. `PSX20', `SV9', ... ).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgIdentRevisionLevel 1.3.6.1.4.1.705.1.1.3
The UPS revision level.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgIdentFirmwareVersion 1.3.6.1.4.1.705.1.1.4
The UPS microprocessor firmware version number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgIdentUserID 1.3.6.1.4.1.705.1.1.5
The UPS user identification (set by administrator).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgIdentInstallationDate 1.3.6.1.4.1.705.1.1.6
The UPS installation date in dd/mm/yy format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgIdentSerialNumber 1.3.6.1.4.1.705.1.1.7
The UPS manufacturing serial number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgManagersNum 1.3.6.1.4.1.705.1.2.1
The number of managers that could manage the UPS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgManagersTable 1.3.6.1.4.1.705.1.2.2
The table of managers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgManagersEntry

upsmgManagersEntry 1.3.6.1.4.1.705.1.2.2.1
The description of a manager entry in the managers table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgManagersEntry  

mgmanagerIndex 1.3.6.1.4.1.705.1.2.2.1.1
A unique value for each manager. Its value ranges between 1 and the value of upsmgManagersNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mgmanagerDeviceNumber 1.3.6.1.4.1.705.1.2.2.1.2
This object is the number of the manager device in the DevicesTable of the Config group. This means that the manager is powered by the UPS. If not the default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgmanagerNMSType 1.3.6.1.4.1.705.1.2.2.1.3
The type of manager according to the NMS platform. We include in the manager class all systems which will be notified by the agent via receiving traps (e.g. basic to complex NMS software).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER umclient(1), decnetview(2), umview(3), dview(4), hpopenview(5), sunnetmanager(6), novellnms(7), ibmnetview(8), other(9), autolearning(10)  

mgmanagerCommType 1.3.6.1.4.1.705.1.2.2.1.4
The level of communication protocol for that manager. Setting this object to value invalid(2) has the effect of invalidating the corresponding entry in the upsmgManagersTable. It is an implementation-specific matter as to wether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entry not currently in use. Proper interpretation of such entries requires examination of the relevant mgmanagerCommType object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), invalid(2), cmip(3), snmpv1(4), snmpv2(5)  

mgmanagerDescr 1.3.6.1.4.1.705.1.2.2.1.5
A textual string containing information about the manager. (manufacturer and version description).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

mgmanagerAddress 1.3.6.1.4.1.705.1.2.2.1.6
The IP address of the manager station receiving traps. The value of this object is meaningful if and only if the value of the relevant mgmanagerCommType object is snmp type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mgmanagerCommunity 1.3.6.1.4.1.705.1.2.2.1.7
The manager community string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

mgmanagerSeverityLevel 1.3.6.1.4.1.705.1.2.2.1.8
The severity level of traps to be received by this manager.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgmanagerTrapAck 1.3.6.1.4.1.705.1.2.2.1.9
The manager Trap Acknowledgement status. Setting this object to mgnoack(2) or stdnomg(3) or cpqnoack(5) disables the trap acknowledgement from the related manager. The MG enterprise specific trap should then be sent only once by the agent to this manager in case of mgnoack(2), and should not be sent by the agent to this manager in case of stdnomg(3) or cpqnoack(5). mgack(1) allows a basic mecanism for acknowledged traps using upsmgAgentTrapAck object set by the manager to the enterprise specific number of the trap. mgacks(5) allows the enhanced mecanism using the upsmgAgentTrapSignature object set by the manager to the signature received within the trap var binding.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mgack(1), mgnoack(2), stdnomg(3), mgacks(4), cpqnoack(5)  

upsmgReceptaclesNum 1.3.6.1.4.1.705.1.3.1
The total number of receptacles controlled by the UPS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgReceptaclesTable 1.3.6.1.4.1.705.1.3.2
The table of receptacles that are controlled by the UPS.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgReceptaclesEntry

upsmgReceptaclesEntry 1.3.6.1.4.1.705.1.3.2.1
The description of a receptacle in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgReceptaclesEntry  

mgreceptacleIndex 1.3.6.1.4.1.705.1.3.2.1.1
A unique value for each receptacle. Its value ranges between 1 and the value of upsmgReceptaclesNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mgreceptacleLevel 1.3.6.1.4.1.705.1.3.2.1.2
The level of receptacle. Setting this object to value invalid(2) has the effect of invalidating the corresponding entry in the upsmgReceptaclesTable. It is an implementation-specific matter as to wether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entry not currently in use. Proper interpretation of such entries requires examination of the relevant receptacleLevel object. Values 1 and 4 are reserved, value 3 is used to identify a simple one-level receptacle, and values greater than 4 represent a group of equivalent receptacles.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptacleType 1.3.6.1.4.1.705.1.3.2.1.3
A textual string for the receptacle type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

mgreceptacleIdent 1.3.6.1.4.1.705.1.3.2.1.4
A textual string identification for the user.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

mgreceptacleState 1.3.6.1.4.1.705.1.3.2.1.5
The ON/OFF status of the receptacle.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER manualON(1), manualOFF(2), normalON(3), normalOFF(4), controlON(5), controlOFF(6), scheduleON(7), scheduleOFF(8)  

mgreceptacleReceptacle 1.3.6.1.4.1.705.1.3.2.1.6
The receptacle number of the second level receptacle father. The value of this object is meaningful if and only if the value of the relevant mgreceptacleType object is related to a two-level receptacle class. Otherwise the default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptaclePowerCons 1.3.6.1.4.1.705.1.3.2.1.7
The volt-ampere rating of the receptacle. The value of this object is meaningful if and only if the value of the relevant mgreceptacleType object is related to a two-level receptacle class. Otherwise the default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptacleOverload 1.3.6.1.4.1.705.1.3.2.1.8
The overload status of the receptacle. The value of this object is meaningful if and only if the value of the relevant mgreceptacleType object is related to a two-level receptacle class. Otherwise the default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptacleAutonomy 1.3.6.1.4.1.705.1.3.2.1.9
The receptacle autonomy. The value of this object is meaningful if and only if the value of the relevant mgreceptacleType object is related to a two-level receptacle class. Otherwise the default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigBatteryInstalled 1.3.6.1.4.1.705.1.4.1
The battery installed status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgConfigNominalBatteryVoltage 1.3.6.1.4.1.705.1.4.2
The nominal battery voltage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigNominalBatteryTime 1.3.6.1.4.1.705.1.4.3
The full load battery autonomy time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigNominalRechargeTime 1.3.6.1.4.1.705.1.4.4
The recharge time to go from low battery cut off to full charge at full load.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigMinRechargeLevel 1.3.6.1.4.1.705.1.4.5
The minimum battery level required to supply power on the loads after low battery condition turn off and restart on main return.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigMaxRechargeTime 1.3.6.1.4.1.705.1.4.6
The maximum time delay of battery recharge before supply power to the loads.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigLowBatteryTime 1.3.6.1.4.1.705.1.4.7
To set remaining time value for low battery condition.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigLowBatteryLevel 1.3.6.1.4.1.705.1.4.8
To set battery level value for low battery condition.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigAutoRestart 1.3.6.1.4.1.705.1.4.9
The automatic restart enabling status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER always(1), never(2), onmain(3)  

upsmgConfigShutdownTimer 1.3.6.1.4.1.705.1.4.10
To set ups shutdown timer from on battery condition.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigSysShutDuration 1.3.6.1.4.1.705.1.4.11
To set ups shutdown delay (Sn delay).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigVARating 1.3.6.1.4.1.705.1.4.12
The UPS nominal VA rating.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigLowTransfer 1.3.6.1.4.1.705.1.4.13
The low voltage transfer point.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigHighTransfer 1.3.6.1.4.1.705.1.4.14
The high voltage transfer point.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigOutputNominalVoltage 1.3.6.1.4.1.705.1.4.15
The nominal output voltage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigOutputNominalCurrent 1.3.6.1.4.1.705.1.4.16
The nominal output current.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigOutputNomFrequency 1.3.6.1.4.1.705.1.4.17
The nominal output frequency.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigByPassType 1.3.6.1.4.1.705.1.4.18
The UPS by pass switch type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), relay(2), static(3)  

upsmgConfigAlarmAudible 1.3.6.1.4.1.705.1.4.19
To set audible alarm status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgConfigAlarmTimeDelay 1.3.6.1.4.1.705.1.4.20
To set audible alarm time delay.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigDevicesNum 1.3.6.1.4.1.705.1.4.21
The number of devices that are powered by the UPS.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigDevicesTable 1.3.6.1.4.1.705.1.4.22
The table of devices that are powered by the UPS.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgConfigDevicesEntry

upsmgConfigDevicesEntry 1.3.6.1.4.1.705.1.4.22.1
The description of a device entry in the devices table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgConfigDevicesEntry  

mgdeviceIndex 1.3.6.1.4.1.705.1.4.22.1.1
A unique value for each device. Its value ranges between 1 and the value of upsmgDevicesNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mgdeviceReceptacleNum 1.3.6.1.4.1.705.1.4.22.1.2
The receptacle number of the device plugged into the UPS. This value gives index entry in the ReceptaclesTable object of the Receptacle group. A value of 0 invalidates the entry in the DevicesTable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgdeviceIdent 1.3.6.1.4.1.705.1.4.22.1.3
A textual string for device user identification.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

mgdeviceVaRating 1.3.6.1.4.1.705.1.4.22.1.4
The volt-ampere rating of the device plugged into the UPS.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgdeviceSequenceOff 1.3.6.1.4.1.705.1.4.22.1.5
To set the device position in the remote shutdown sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgdeviceSequenceOn 1.3.6.1.4.1.705.1.4.22.1.6
To set the device position in the remote reboot sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgdeviceShutdownDuration 1.3.6.1.4.1.705.1.4.22.1.7
To set the duration from start of computer shut-down to complete.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgdeviceBootUpDuration 1.3.6.1.4.1.705.1.4.22.1.8
To set the duration from start of computer boot-up to complete.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigReceptaclesTable 1.3.6.1.4.1.705.1.4.23
The table of receptacles.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgConfigReceptaclesEntry

upsmgConfigReceptaclesEntry 1.3.6.1.4.1.705.1.4.23.1
The description of a receptacle entry in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgConfigReceptaclesEntry  

mgreceptacleIndexb 1.3.6.1.4.1.705.1.4.23.1.1
A unique value for each receptacle. Its value ranges between 1 and the value of upsmgReceptaclesNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mgreceptacleStateTurnOn 1.3.6.1.4.1.705.1.4.23.1.2
Default return state at turn on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), last(3), schedule(4)  

mgreceptacleStateMainReturn 1.3.6.1.4.1.705.1.4.23.1.3
Default return state on main return.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), last(3), schedule(4)  

mgreceptacleStateDischarge 1.3.6.1.4.1.705.1.4.23.1.4
Default return state on main return from battery discharge.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), last(3), schedule(4)  

mgreceptacleShutoffLevel 1.3.6.1.4.1.705.1.4.23.1.5
Battery level for starting shutoff sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptacleShutoffTimer 1.3.6.1.4.1.705.1.4.23.1.6
Time delay from on battery for starting shutoff sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptacleRestartLevel 1.3.6.1.4.1.705.1.4.23.1.7
Battery level for starting restart sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptacleRestartDelay 1.3.6.1.4.1.705.1.4.23.1.8
Time delay for starting restart sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptacleShutdownDuration 1.3.6.1.4.1.705.1.4.23.1.9
Maximum Shutdown Duration for systems powered by this plug.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mgreceptacleBootUpDuration 1.3.6.1.4.1.705.1.4.23.1.10
Maximum Reboot Duration for systems powered by this plug.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgConfigExtAlarmNum 1.3.6.1.4.1.705.1.4.24
The number of environ external alarm, value is between 8 and 32..
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgConfigExtAlarmTable 1.3.6.1.4.1.705.1.4.25
The table of environmental external alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgConfigExtAlarmEntry

upsmgConfigExtAlarmEntry 1.3.6.1.4.1.705.1.4.25.1
The description of an external alarm in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgConfigExtAlarmEntry  

mgextAlarmIndex 1.3.6.1.4.1.705.1.4.25.1.1
A unique value for each external alarm. Its value ranges between 1 and the value of upsmgConfigExtAlarmNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mgextAlarmUID 1.3.6.1.4.1.705.1.4.25.1.2
A textual string for alarm state user identification.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgConfigEmergencyTestFail 1.3.6.1.4.1.705.1.4.26
The emergency condition status on Battery test fail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgConfigEmergencyOnByPass 1.3.6.1.4.1.705.1.4.27
The emergency condition status on By Pass.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgConfigEmergencyOverload 1.3.6.1.4.1.705.1.4.28
The emergency condition status on overload.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgConfigControlDayTable 1.3.6.1.4.1.705.1.4.29
The table of daily on/off time.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgConfigControlDayEntry

upsmgConfigControlDayEntry 1.3.6.1.4.1.705.1.4.29.1
The description of a daily on/off time schedule in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgConfigControlDayEntry  

mgcontrolDayIndex 1.3.6.1.4.1.705.1.4.29.1.1
The day index. It is a number between 1 and 7, 1 for Sunday, 2 for Monday, ...
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mgcontrolDayOn 1.3.6.1.4.1.705.1.4.29.1.2
To set daily power on time. Any value greater than 86400 is to disable the Day On.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgcontrolDayOff 1.3.6.1.4.1.705.1.4.29.1.3
To set daily power off time. Any value greater than 86400 is to disable the Day Off.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigLowBooster 1.3.6.1.4.1.705.1.4.30
To set UPS booster low threshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigHighBooster 1.3.6.1.4.1.705.1.4.31
To set UPS booster high threshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigLowFader 1.3.6.1.4.1.705.1.4.32
To set UPS fader low threshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigHighFader 1.3.6.1.4.1.705.1.4.33
To set UPS fader high threshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigEnvironmentTable 1.3.6.1.4.1.705.1.4.34
The table containing the configuration of the environment sensor.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgConfigEnvironmentEntry

upsmgConfigEnvironmentEntry 1.3.6.1.4.1.705.1.4.34.1
The description of an entry in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgConfigEnvironmentEntry  

upsmgConfigSensorIndex 1.3.6.1.4.1.705.1.4.34.1.1
The sensor index, ranging from 1 to upsmgEnvironmentNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..50  

upsmgConfigSensorName 1.3.6.1.4.1.705.1.4.34.1.2
The sensor user-friendly name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..42)  

upsmgConfigTemperatureLow 1.3.6.1.4.1.705.1.4.34.1.3
The low temperature threshold in unit 0.1 Cel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigTemperatureHigh 1.3.6.1.4.1.705.1.4.34.1.4
The high temperature threshold in unit 0.1 Cel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigTemperatureHysteresis 1.3.6.1.4.1.705.1.4.34.1.5
The temperature hysteresys used for threshold test in unit 0.1 Cel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigHumidityLow 1.3.6.1.4.1.705.1.4.34.1.6
The low humidity threshold in unit 1 %.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigHumidityHigh 1.3.6.1.4.1.705.1.4.34.1.7
The high humidity threshold in unit 1 %.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigHumidityHysteresis 1.3.6.1.4.1.705.1.4.34.1.8
The humidity hysteresys used for threshold test in unit 1 %.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgConfigInput1Name 1.3.6.1.4.1.705.1.4.34.1.9
The Input #1 user-friendly name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..22)  

upsmgConfigInput1ClosedLabel 1.3.6.1.4.1.705.1.4.34.1.10
The Input #1 label for closed position.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..18)  

upsmgConfigInput1OpenLabel 1.3.6.1.4.1.705.1.4.34.1.11
The Input #1 label for open position.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..18)  

upsmgConfigInput2Name 1.3.6.1.4.1.705.1.4.34.1.12
The Input #2 user-friendly name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..22)  

upsmgConfigInput2ClosedLabel 1.3.6.1.4.1.705.1.4.34.1.13
The Input #2 label for closed position.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..18)  

upsmgConfigInput2OpenLabel 1.3.6.1.4.1.705.1.4.34.1.14
The Input #2 label for open position.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..18)  

upsmgBatteryRemainingTime 1.3.6.1.4.1.705.1.5.1
The time remaining actual charge vs actual load (dynamic).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgBatteryLevel 1.3.6.1.4.1.705.1.5.2
The battery level as a percentage of charge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgBatteryRechargeTime 1.3.6.1.4.1.705.1.5.3
The actual operational battery recharge time to set point equal to upsmgConfigRechargeLevel. This value is computed from upsmgConfigRechargeLevel (level to reach), upsmgBatteryLevel (the actual reached level) and the UPS charge rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgBatteryRechargeLevel 1.3.6.1.4.1.705.1.5.4
The actual value of the battery recharge level that will be reached during the time delay necessary to restart after power returns. This value is computed from upsmgConfigRechargeTime (the delay), upsmgBatteryLevel (the actual level) and the UPS charge rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgBatteryVoltage 1.3.6.1.4.1.705.1.5.5
The actual battery voltage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgBatteryCurrent 1.3.6.1.4.1.705.1.5.6
The actual battery current.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgBatteryTemperature 1.3.6.1.4.1.705.1.5.7
The battery temperature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgBatteryFullRechargeTime 1.3.6.1.4.1.705.1.5.8
The battery full recharge time (from 0 to 100 percent) at current load.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgBatteryFaultBattery 1.3.6.1.4.1.705.1.5.9
The battery fault status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgBatteryNoBattery 1.3.6.1.4.1.705.1.5.10
The UPS has no Battery status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgBatteryReplacement 1.3.6.1.4.1.705.1.5.11
The UPS Battery to be replaced status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgBatteryUnavailableBattery 1.3.6.1.4.1.705.1.5.12
The UPS Battery is unavailable status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgBatteryNotHighCharge 1.3.6.1.4.1.705.1.5.13
The UPS Battery quit high condition status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgBatteryLowBattery 1.3.6.1.4.1.705.1.5.14
The battery low status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgBatteryChargerFault 1.3.6.1.4.1.705.1.5.15
The UPS Battery is not charging status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgBatteryLowCondition 1.3.6.1.4.1.705.1.5.16
The UPS is at low condition status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgBatteryLowRecharge 1.3.6.1.4.1.705.1.5.17
The UPS Battery is not recharged status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgInputPhaseNum 1.3.6.1.4.1.705.1.6.1
The number of input phases.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgInputPhaseTable 1.3.6.1.4.1.705.1.6.2
The table of input phases.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgInputPhaseEntry

upsmgInputPhaseEntry 1.3.6.1.4.1.705.1.6.2.1
The description of an input phase.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgInputPhaseEntry  

mginputIndex 1.3.6.1.4.1.705.1.6.2.1.1
The input phase voltage index. It is a number between 1 and upsmgInputPhaseNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mginputVoltage 1.3.6.1.4.1.705.1.6.2.1.2
The input phase voltage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mginputFrequency 1.3.6.1.4.1.705.1.6.2.1.3
The input phase frequency.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mginputMinimumVoltage 1.3.6.1.4.1.705.1.6.2.1.4
The input phase minimum voltage over the last minute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mginputMaximumVoltage 1.3.6.1.4.1.705.1.6.2.1.5
The input phase maximum voltage over the last minute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mginputCurrent 1.3.6.1.4.1.705.1.6.2.1.6
The input phase current.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgInputBadStatus 1.3.6.1.4.1.705.1.6.3
The utility power bad voltage or bad frequency status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgInputLineFailCause 1.3.6.1.4.1.705.1.6.4
The utility power failure cause: no(1) is for no utility failure, outoftolvolt(2) is for voltage out of tolerance, outoftolfreq(3) is for frequency out of tolerance, utilityoff(4) is for no voltage at all.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), outoftolvolt(2), outoftolfreq(3), utilityoff(4)  

upsmgOutputPhaseNum 1.3.6.1.4.1.705.1.7.1
The number of output phases.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgOutputPhaseTable 1.3.6.1.4.1.705.1.7.2
The table of output phases.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgOutputPhaseEntry

upsmgOutputPhaseEntry 1.3.6.1.4.1.705.1.7.2.1
The description of an output phase.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgOutputPhaseEntry  

mgoutputPhaseIndex 1.3.6.1.4.1.705.1.7.2.1.1
The output phase voltage index. It is a number between 1 and upsmgOutputPhaseNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mgoutputVoltage 1.3.6.1.4.1.705.1.7.2.1.2
The output phase voltage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mgoutputFrequency 1.3.6.1.4.1.705.1.7.2.1.3
The output phase frequency.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mgoutputLoadPerPhase 1.3.6.1.4.1.705.1.7.2.1.4
The output load per phase.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mgoutputCurrent 1.3.6.1.4.1.705.1.7.2.1.5
The output phase current.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgOutputOnBattery 1.3.6.1.4.1.705.1.7.3
The UPS on battery / on main status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgOutputOnByPass 1.3.6.1.4.1.705.1.7.4
The UPS on bypass status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgOutputUnavailableByPass 1.3.6.1.4.1.705.1.7.5
The by pass unavailable status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgOutputNoByPass 1.3.6.1.4.1.705.1.7.6
The UPS bypass installed status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgOutputUtilityOff 1.3.6.1.4.1.705.1.7.7
The UPS utility off status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgOutputOnBoost 1.3.6.1.4.1.705.1.7.8
The UPS on booster status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgOutputInverterOff 1.3.6.1.4.1.705.1.7.9
The UPS Inverter on / off status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgOutputOverLoad 1.3.6.1.4.1.705.1.7.10
The output over load status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgOutputOverTemp 1.3.6.1.4.1.705.1.7.11
The ups over temperature status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgOutputOnBuck 1.3.6.1.4.1.705.1.7.12
The UPS on fader status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgEnvironAmbientTemp 1.3.6.1.4.1.705.1.8.1
The ambient temperature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgEnvironAmbientHumidity 1.3.6.1.4.1.705.1.8.2
The ambient humidity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgEnvironExtAlarmTable 1.3.6.1.4.1.705.1.8.3
The table of external alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgEnvironExtAlarmEntry

upsmgEnvironExtAlarmEntry 1.3.6.1.4.1.705.1.8.3.1
The description of an external alarm.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgEnvironExtAlarmEntry  

mgalarmNum 1.3.6.1.4.1.705.1.8.3.1.1
The external alarm number. A number between 1 and upsmgConfigExtAlarmNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mgalarmState 1.3.6.1.4.1.705.1.8.3.1.2
The external alarm state (active or inactive).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

upsmgEnvironSensorNum 1.3.6.1.4.1.705.1.8.4
The sensor unit number (0 to 4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgEnvironSensorTable 1.3.6.1.4.1.705.1.8.5
The table of sensor units.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgEnvironSensorEntry

upsmgEnvironSensorEntry 1.3.6.1.4.1.705.1.8.5.1
The description of a sensor unit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgEnvironSensorEntry  

mgsensorNum 1.3.6.1.4.1.705.1.8.5.1.1
The unit number. A number between 1 and 4.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mgsensorTemp 1.3.6.1.4.1.705.1.8.5.1.2
The measured temperature of the unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mgsensorHumidity 1.3.6.1.4.1.705.1.8.5.1.3
The measured humidity of the unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgEnvironmentNum 1.3.6.1.4.1.705.1.8.6
Number of Environment sensor connected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgEnvironmentSensorTable 1.3.6.1.4.1.705.1.8.7
The table containing the measurements and alarms made by Environment sensor units.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgEnvironmentSensorEntry

upsmgEnvironmentSensorEntry 1.3.6.1.4.1.705.1.8.7.1
The description of an entry in the measurement table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgEnvironmentSensorEntry  

upsmgEnvironmentIndex 1.3.6.1.4.1.705.1.8.7.1.1
The sensor index, ranging from 1 to upsmgEnvironmentNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

upsmgEnvironmentComFailure 1.3.6.1.4.1.705.1.8.7.1.2
The sensor communication failure : yes(1), no(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgEnvironmentTemperature 1.3.6.1.4.1.705.1.8.7.1.3
The temperature measurement in unit 0.1 Cel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgEnvironmentTemperatureLow 1.3.6.1.4.1.705.1.8.7.1.4
Temperature is below low theshold : yes(1), no(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgEnvironmentTemperatureHigh 1.3.6.1.4.1.705.1.8.7.1.5
Temperature is above high threshold : yes(1), no(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgEnvironmentHumidity 1.3.6.1.4.1.705.1.8.7.1.6
The humidity measurement in unit 0.1 %.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgEnvironmentHumidityLow 1.3.6.1.4.1.705.1.8.7.1.7
Humidity is below low threshold : yes(1), no(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgEnvironmentHumidityHigh 1.3.6.1.4.1.705.1.8.7.1.8
Humidity is above high threshold : yes(1), no(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgEnvironmentInput1State 1.3.6.1.4.1.705.1.8.7.1.9
State of Input#1 : closed(1), open(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER closed(1), open(2)  

upsmgEnvironmentInput2State 1.3.6.1.4.1.705.1.8.7.1.10
State of Input#2 : closed(1), open(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER closed(1), open(2)  

upsmgControlReceptaclesTable 1.3.6.1.4.1.705.1.9.1
The table of receptacles.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsmgControlReceptaclesEntry

upsmgControlReceptaclesEntry 1.3.6.1.4.1.705.1.9.1.1
The description of a receptacle entry in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsmgControlReceptaclesEntry  

mgreceptacleIndexc 1.3.6.1.4.1.705.1.9.1.1.1
A unique value for each receptacle. Its value ranges between 1 and the value of upsmgReceptaclesNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..50  

mgreceptacleOnDelay 1.3.6.1.4.1.705.1.9.1.1.2
Turn on UPS receptacle w/delay=?.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptacleOnCtrl 1.3.6.1.4.1.705.1.9.1.1.3
The receptacle control on action.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nothing(1), start(2), stop(3)  

mgreceptacleOnStatus 1.3.6.1.4.1.705.1.9.1.1.4
The receptacle control on status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), started(2), inprogressinups(3), completed(4)  

mgreceptacleOffDelay 1.3.6.1.4.1.705.1.9.1.1.5
Turn off UPS receptacle w/delay=?.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptacleOffCtrl 1.3.6.1.4.1.705.1.9.1.1.6
The receptacle control off action.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nothing(1), start(2), stop(3)  

mgreceptacleOffStatus 1.3.6.1.4.1.705.1.9.1.1.7
The receptacle control off status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), started(2), inprogressinups(3), completed(4)  

mgreceptacleToggleDelay 1.3.6.1.4.1.705.1.9.1.1.8
Turn off then on UPS receptacle w/delay=?.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgreceptacleToggleCtrl 1.3.6.1.4.1.705.1.9.1.1.9
The receptacle control toggle action.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nothing(1), start(2), stop(3)  

mgreceptacleToggleStatus 1.3.6.1.4.1.705.1.9.1.1.10
The receptacle control toggle status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), started(2), inprogressinups(3), completed(4)  

mgreceptacleToggleDuration 1.3.6.1.4.1.705.1.9.1.1.11
Turn off then on UPS receptacle w/duration=?.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgControlDayOff 1.3.6.1.4.1.705.1.9.2
The schedule off control object. Default value is none(8). Value 1 means to start scheduled off on Sunday, value 2 to start scheduled off on Monday, and so on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saterday(7), none(8)  

upsmgControlDayOn 1.3.6.1.4.1.705.1.9.3
The schedule on control object. Default value is none(8). Value 1 means to start scheduled on on Sunday, value 2 to start scheduled on on Monday, and so on. This object is meaningfull only for those agent that do not include internal clock. In such a case the object is set by a manager to start the schedule on sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saterday(7), none(8)  

upsmgTestBatterySchedule 1.3.6.1.4.1.705.1.10.1
The automatic battery test schedule.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), weekly(2), monthly(3), atturnon(4), none(5), dayly(6)  

upsmgTestDiagnostics 1.3.6.1.4.1.705.1.10.2
To run self test diagnostics.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER default(1), start(2)  

upsmgTestDiagResult 1.3.6.1.4.1.705.1.10.3
The automatic test diagnostic result.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER success(1), failed(2), none(3)  

upsmgTestBatteryCalibration 1.3.6.1.4.1.705.1.10.4
To run battery test calibration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER default(1), start(2)  

upsmgTestLastCalibration 1.3.6.1.4.1.705.1.10.5
The last battery calibration test date.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgTestIndicators 1.3.6.1.4.1.705.1.10.6
To run UPS indicators test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgTestCommandLine 1.3.6.1.4.1.705.1.10.7
To send ASCII command line to UPS.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgTestCommandReady 1.3.6.1.4.1.705.1.10.8
To advise UPS that command line has been prepared.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgTestResponseLine 1.3.6.1.4.1.705.1.10.9
To get ASCII protocol response from UPS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgTestResponseReady 1.3.6.1.4.1.705.1.10.10
To advise agent that response line has been received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgTestBatteryResult 1.3.6.1.4.1.705.1.10.11
The test battery result: msuccess(1) is for manual battery test success, ssuccess(3) is for scheduled battery test success, mfailed(2) is for manual battery test failed, sfailed(4) is for scheduled battery test failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER msuccess(1), mfailed(2), ssuccess(3), sfailed(4), none(5)  

upsmgBatteryFault 1
Trap UPS Battery entering Fault status.
TRAP-TYPE    

upsmgBatteryOK 2
Trap UPS Battery returned to OK status.
TRAP-TYPE    

upsmgBatteryReplacementIndicated 3
Trap UPS battery need to be replaced.
TRAP-TYPE    

upsmgBatteryReplaceNotIndicated 4
Trap UPS battery does not need to be replaced.
TRAP-TYPE    

upsmgAtLowBattery 5
Trap UPS battery reached low condition.
TRAP-TYPE    

upsmgFromLowBattery 6
Trap UPS battery returned from low condition.
TRAP-TYPE    

upsmgChargerFault 7
Trap UPS battery charger is not active.
TRAP-TYPE    

upsmgChargerOK 8
Trap UPS battery charger is active.
TRAP-TYPE    

upsmgAtLowCondition 9
Trap UPS entering low condition.
TRAP-TYPE    

upsmgFromLowCondition 10
Trap UPS exiting low condition.
TRAP-TYPE    

upsmgOnBattery 11
Trap UPS is on Battery.
TRAP-TYPE    

upsmgReturnFromBattery 12
Trap UPS returned from battery.
TRAP-TYPE    

upsmgOnByPass 13
Trap UPS is on by pass.
TRAP-TYPE    

upsmgReturnFromByPass 14
Trap UPS return from by pass.
TRAP-TYPE    

upsmgByPassUnavailable 15
Trap UPS by pass unavailable.
TRAP-TYPE    

upsmgByPassAvailable 16
Trap UPS by pass available.
TRAP-TYPE    

upsmgUtilityFailure 17
Trap UPS utility power failed.
TRAP-TYPE    

upsmgUtilityRestored 18
Trap UPS utility power restored.
TRAP-TYPE    

upsmgOnBoost 19
Trap UPS is on boost.
TRAP-TYPE    

upsmgReturnFromBoost 20
Trap UPS has returned from boost.
TRAP-TYPE    

upsmgOverLoad 21
Trap UPS has overload condition.
TRAP-TYPE    

upsmgLoadOK 22
Trap UPS quit overload condition.
TRAP-TYPE    

upsmgOverTemperature 23
Trap UPS has overtemperature condition.
TRAP-TYPE    

upsmgTemperatureOK 24
Trap UPS quit overtemperature condition.
TRAP-TYPE    

upsmgOnToStart 25
Trap UPS on sequence started.
TRAP-TYPE    

upsmgOnAbort 26
Trap UPS on sequence cancelled.
TRAP-TYPE    

upsmgOnInProgress 27
Trap UPS on sequence in progress in ups.
TRAP-TYPE    

upsmgOnComplete 28
Trap UPS on sequence completed.
TRAP-TYPE    

upsmgOffToStart 29
Trap UPS off sequence started.
TRAP-TYPE    

upsmgOffAbort 30
Trap UPS off sequence cancelled.
TRAP-TYPE    

upsmgOffInProgress 31
Trap UPS off sequence in progress in ups.
TRAP-TYPE    

upsmgOffComplete 32
Trap UPS off sequence completed.
TRAP-TYPE    

upsmgToggleToStart 33
Trap UPS toggle (off/on) sequence started.
TRAP-TYPE    

upsmgToggleAbort 34
Trap UPS toggle (off/on) sequence cancelled.
TRAP-TYPE    

upsmgToggleInProgress 35
Trap UPS toggle (off/on) sequence in progress in ups.
TRAP-TYPE    

upsmgToggleComplete 36
Trap UPS toggle (off/on) sequence completed.
TRAP-TYPE    

upsmgCommunicationFailure 37
Trap UPS serial communication failed.
TRAP-TYPE    

upsmgCommunicationRestored 38
Trap UPS serial communication restored.
TRAP-TYPE    

upsmgInputBad 39
Trap UPS input has bad condition.
TRAP-TYPE    

upsmgInputOK 40
Trap UPS input quit bad condition.
TRAP-TYPE    

upsmgBatteryUnavailable 41
Trap UPS battery is unavailable.
TRAP-TYPE    

upsmgBatteryAvailable 42
Trap UPS battery return from unavailable condition.
TRAP-TYPE    

upsmgAtLowRecharge 43
Trap UPS waiting for battery charging condition.
TRAP-TYPE    

upsmgFromLowRecharge 44
Trap UPS reached battery charging condition.
TRAP-TYPE    

upsmgDiagnosticTestFail 45
Trap UPS self test failed.
TRAP-TYPE    

upsmgDiagnosticTestOK 46
Trap UPS self test succeeded.
TRAP-TYPE    

upsmgBatteryTestOK 47
Trap UPS passed battery test.
TRAP-TYPE    

upsmgBatteryTestFail 48
Trap UPS failed battery test.
TRAP-TYPE    

upsmgExternalAlarmActive 49
Trap UPS enter environment external alarm.
TRAP-TYPE    

upsmgExternalAlarmInactive 50
Trap UPS exit environment external alarm.
TRAP-TYPE    

upsmgOnBuck 51
Trap UPS is on buck.
TRAP-TYPE    

upsmgReturnFromBuck 52
Trap UPS has returned from buck.
TRAP-TYPE    

upsmgEnvironComFailure 53
Environment Probe communication failure.
TRAP-TYPE    

upsmgEnvironComOK 54
Environment Probe communication restored.
TRAP-TYPE    

upsmgEnvironTemperatureLow 55
Temperature is below low threshold.
TRAP-TYPE    

upsmgEnvironTemperatureHigh 56
Temperature is above high threshold.
TRAP-TYPE    

upsmgEnvironTemperatureOK 57
Temperature is in normal range.
TRAP-TYPE    

upsmgEnvironHumidityLow 58
Humidity is below low threshold.
TRAP-TYPE    

upsmgEnvironHumidityHigh 59
Humidity is above high threshold.
TRAP-TYPE    

upsmgEnvironHumidityOK 60
Humidity is in normal range.
TRAP-TYPE    

upsmgEnvironInput1Closed 61
Input #1 is Closed.
TRAP-TYPE    

upsmgEnvironInput1Open 62
Input #1 is Open.
TRAP-TYPE    

upsmgEnvironInput2Closed 63
Input #2 is Closed.
TRAP-TYPE    

upsmgEnvironInput2Open 64
Input #2 is Open.
TRAP-TYPE    

upsmgAgentIpaddress 1.3.6.1.4.1.705.1.12.1
The ip address that NMS can identify the managed device
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

upsmgAgentSubnetMask 1.3.6.1.4.1.705.1.12.2
Internet address subnet mask
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

upsmgAgentDefGateway 1.3.6.1.4.1.705.1.12.3
The default gateway that allow device managed through routers
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

upsmgAgentBaudRate 1.3.6.1.4.1.705.1.12.4
the serial port communication speed. only 2400, 4800, and 9600 allowed
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgAgentPollRate 1.3.6.1.4.1.705.1.12.5
The frequency that proxy agent polls the connected UPS in ASCII protocol. (unit : second)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgAgentType 1.3.6.1.4.1.705.1.12.6
The type of agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER deviceEth(1), deviceTR(2), proxyEth(3), proxyTR(4), other(5)  

upsmgAgentTrapAlarmDelay 1.3.6.1.4.1.705.1.12.7
The interval for the Trap packet retransmission, while the TRAP Acknowledge is implemented and the ack is received within the interval.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgAgentTrapAlarmRetry 1.3.6.1.4.1.705.1.12.8
The retry count for retransmitting Trap packet while the TRAP acknowledge is implemented.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgAgentReset 1.3.6.1.4.1.705.1.12.9
The variable initiates reset operation in agent software, ie. warm start. write reset(1) to any one of UPS MIB array, will result in the same reset operation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), nothing(2)  

upsmgAgentFactReset 1.3.6.1.4.1.705.1.12.10
The variable initiates reset operation in agent software, ie. warm start, and load default data (Factory setting) to EEPROM and to runtime parameters associated with the UPS.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), nothing(2)  

upsmgAgentMibVersion 1.3.6.1.4.1.705.1.12.11
The version of the MIB implemented in agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgAgentFirmwareVersion 1.3.6.1.4.1.705.1.12.12
The agent firmware version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

upsmgAgentCommUPS 1.3.6.1.4.1.705.1.12.13
The status of communication between agent and ups. Even value means no communication, and odd value means a certain level of communication with devices daisy-chained on the serial port. The value is the following: 1000*NSE + 100*NSW + 10*UPSW + UPST with UPST is UPS type: 5 if no UPS; 3 if PI (Protocol Interface) 1 if U-Talk UPS; UPSW is the number of switchable plugs of the UPS; NSW is the number of UM-Switch devices; NSE is the number of UM-Sensor devices.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgAgentTrapAck 1.3.6.1.4.1.705.1.12.14
The last Trap number that has been received by UM-View.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgAgentAutoLearning 1.3.6.1.4.1.705.1.12.15
The enabled/disabled configuration of the Auto Learning process of the agent, default value is yes(1) e.g. enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgAgentBootP 1.3.6.1.4.1.705.1.12.16
The enabled/disabled configuration of the BootP process, default value is yes(1) e.g. enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgAgentTFTP 1.3.6.1.4.1.705.1.12.17
The enabled/disabled configuration of the TFTP process, default value is no(2) e.g. disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsmgAgentTrapSignature 1.3.6.1.4.1.705.1.12.18
The signature of the trap acknowledged by a manager.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsmgRemoteOnBattery 1.3.6.1.4.1.705.1.13.1
An object to inform an ups-less agent that the remote UPS is on autonomy. This object could be set by a management application.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

upsmgRemoteIpAddress 1.3.6.1.4.1.705.1.13.2
An object to give the IP address of the agent managing the remote UPS. This object could be read by managers to perform management of receptacle dependencies between two different agents.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress