MERITAGE-MIB

File: MERITAGE-MIB.mib (19642 bytes)

Imported modules

GEN-MIB RFC1213-MIB RFC-1212

Imported symbols

lannet DisplayString OBJECT-TYPE

Defined Types

MeritageBaseFanEntry  
SEQUENCE    
  meritageBaseFanId INTEGER
  meritageBaseFanActivityStatus INTEGER

MeritageBasePSUEntry  
SEQUENCE    
  meritageBasePSUId INTEGER
  meritageBasePSUType INTEGER
  meritageBasePSUHWVersion DisplayString
  meritageBasePSURatedPower INTEGER
  meritageBasePSUActivityStatus INTEGER

MeritageGroupEntry  
SEQUENCE    
  meritageGroupIndex INTEGER
  meritageGroupTempExceed INTEGER
  meritageGroupLEDsMap OCTET STRING

MeritageClockSourceEntry  
SEQUENCE    
  meritageClockSourceIndex INTEGER
  meritageClockSourceStatus INTEGER
  meritageClockSourcePriority INTEGER
  meritageClockSourceConfigPort DisplayString
  meritageClockSourceFraming INTEGER

Defined Values

meritage 1.3.6.1.4.1.81.32
OBJECT IDENTIFIER    

meritageBase 1.3.6.1.4.1.81.32.1
OBJECT IDENTIFIER    

meritageMSPV 1.3.6.1.4.1.81.32.2
OBJECT IDENTIFIER    

meritageGroup 1.3.6.1.4.1.81.32.3
OBJECT IDENTIFIER    

meritageClock 1.3.6.1.4.1.81.32.4
OBJECT IDENTIFIER    

meritageClockSource 1.3.6.1.4.1.81.32.5
OBJECT IDENTIFIER    

meritageBaseLEDs 1.3.6.1.4.1.81.32.1.1
Summary of the hub LEDs. The coding of each LED is defined in meritageLedColour Number of bits per LED, currently 8 (1st byte) Number of LEDs, currently 8 (2nd byte) PS1 LED (3rd byte) PS2 LED PS3 LED Fan1 LED Fan2 LED MSPV1 LED MSPV2 LED Eth Sideband LED (last byte)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

meritageBaseTemperatureExceed 1.3.6.1.4.1.81.32.1.2
Fault condition indicating that the temperature exceeded 70 degrees in at least one of the modules in the hub.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), exceeded(2), notSupported(255)  

meritageBaseXswitchConfiguration 1.3.6.1.4.1.81.32.1.3
The value of this attribute shows whether the two horizontal Xswitches are connected internally to form a single 14-slots-wide Xswitch in the Meritage, or not.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER connected(1), separated(2), notSupported(255)  

meritageBaseFaultMask 1.3.6.1.4.1.81.32.1.4
Each bit of this item describes a fault situation in the Meritage hub. bit 1: meritageBaseFanActivityStatus.1 = failed (2), bit 2: meritageBaseFanActivityStatus.2 = failed (2), bit 3: meritageBasePSUActivityStatus.1 = failed(2), bit 4: meritageBasePSUActivityStatus.2 = failed(2), bit 5: meritageBasePSUActivityStatus.3 = failed(2), bit 6: meritageMSPVBackupStatus = failed(2), bit 7: scGenSwitchOldVersionModules.1 = null, bit 8: scGenSwitchOldVersionModules.2 = null, bit 9: scGenSwitchVIDPNonSupportedModules.1 = null, bit 10: scGenSwitchVIDPNonSupportedModules.2 = null, bit 11: scGenSwitchSTAonSupportedModules.1 = null, bit 12: scGenSwitchSTAonSupportedModules.2 = null, bit 13: scGenSwitchIDSonSupportedModules.1 = null, bit 14: scGenSwitchIDSonSupportedModules.2 = null, bit 15: The highest priority source port is not the curent source (according to meritageClockCurrentSource), bit 16: meritageClockStatus is Not in locked (1) for more then 120 seconds AND not all priorities are 0 AND meritageClockAdminStatus = enable (1), bit 17: meritageClockSourceStatus.1 = failed (2), bit 18: meritageClockSourceStatus.2 = failed (2), bit 19: meritageClockSourceStatus.3 = failed (2), bit 20: meritageClockSourceStatus.4 = failed (2),
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

meritageBaseFanTable 1.3.6.1.4.1.81.32.1.5
Table of attributes for Fan units in the Meritage.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MeritageBaseFanEntry

meritageBaseFanEntry 1.3.6.1.4.1.81.32.1.5.1
An entry in the table, containing attributes for a single Fan unit in the Meritage.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MeritageBaseFanEntry  

meritageBaseFanId 1.3.6.1.4.1.81.32.1.5.1.1
Fan index for identifying the Fan in the Meritage 1-left, 2-right.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

meritageBaseFanActivityStatus 1.3.6.1.4.1.81.32.1.5.1.2
This attribute defines the status of the Fan.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), failed(2), none(3)  

meritageBasePSUTable 1.3.6.1.4.1.81.32.1.6
Table of configuration attributes for the Power Supply Units.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MeritageBasePSUEntry

meritageBasePSUEntry 1.3.6.1.4.1.81.32.1.6.1
An entry in the table, containing information for a single Power Supply Unit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MeritageBasePSUEntry  

meritageBasePSUId 1.3.6.1.4.1.81.32.1.6.1.1
Index identifying the PSU.1-left, 2-middle, 3-right.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

meritageBasePSUType 1.3.6.1.4.1.81.32.1.6.1.2
This attribute indicates the PSU type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER m-ps500(1), m-ps1250(2), m-ps800(3), m-ps800-dc(4), notSupported(255)  

meritageBasePSUHWVersion 1.3.6.1.4.1.81.32.1.6.1.3
Hardware version of the PSU. Stored in ASCII format : first Byte - hardware major version number Second Byte - hardware minor version number (Configuration Symbol) last Byte - hardware debug version number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(3)  

meritageBasePSURatedPower 1.3.6.1.4.1.81.32.1.6.1.4
This attribute indicates the rated power of the PSU in Watts.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

meritageBasePSUActivityStatus 1.3.6.1.4.1.81.32.1.6.1.5
This attribute defines the status of the PSU: active(1) - indicates that the PSU supplies power to the chassis. failed(2) - indicates PSU failure none(3) - indicates absence of PSU from the configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), failed(2), none(3)  

meritageBaseUpBckplnConfiguration 1.3.6.1.4.1.81.32.1.7
Defines whether the Upper Backplane is constructed as a single domain (full), as a dual domain (split) or not installed. The hardware supports 2 bits for this purpose (A10, B10 MSB). single - 10 in the MSB HW registers dual - 01 in the MSB HW registers notInstalled - 11 in the MSB HW registers
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER singleDomain(1), dualDomain(2), notInstalled(3), notSupported(255)  

meritageBaseUpBckplnConfigurationSymbol 1.3.6.1.4.1.81.32.1.8
Defines the Configuration Symbol of the Upper Backplane X.Y - where X & Y are integers: 1st byte (X) - Major version number 2nd byte - '.' 3rd byte (Y) - minor version number The hardware supports 2 bits for this purpose (D10, E10 LSB). Y will always be 0. X will change according to the HW registers. 00 is CS 1.0, 01 is 2.0, 10 is 3.0, 11 is 4.0. If no upper backplane is installed in the chassis, an empty string will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

meritageMSPVBackupStatus 1.3.6.1.4.1.81.32.2.1
This attribute defines the status of the backup M-SPV module in the Meritage: dormant (1) - indicates that the backup M-SPV is dormant and works ok. failed (2) - indicates that the backup M-SPV has failed. none (3) - indicates absence of the backup M-SPV from the hub.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dormant(1), failed(2), none(3), notSupported(255)  

meritageMSPVMainPosition 1.3.6.1.4.1.81.32.2.2
This attribute defines the position of the main M-SPV module in the Meritage: MSPV1 (1) - indicates that the main M-SPV is the one on the left slot MSPV2 (2) - indicates that the main M-SPV is the one on the right slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER mMSPV1(1), mMSPV2(2), notSupported(255)  

meritageGroupTable 1.3.6.1.4.1.81.32.3.1
A table containing information about each group in the hub.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MeritageGroupEntry

meritageGroupEntry 1.3.6.1.4.1.81.32.3.1.1
An entry containing information about a particular group in the hub.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MeritageGroupEntry  

meritageGroupIndex 1.3.6.1.4.1.81.32.3.1.1.1
Index into this table, by group number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

meritageGroupTempExceed 1.3.6.1.4.1.81.32.3.1.1.2
Fault condition indicating that temperature exceeded the threshold on the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), exceeded(2), notSupported(255)  

meritageGroupLEDsMap 1.3.6.1.4.1.81.32.3.1.1.3
The status of all the Group LEDs in the form of a BIT Map. The coding of each LED is defined in MeritageLedColour. The structure of this item: Number of bits per LED = A (currently 8 bits) (1st byte) Number of Module level LEDs = B (currently 2) (2nd byte) Number of Ports = C (currently 12) (3rd byte) Number of Functions = D (currently 6) (4th byte) Module level LEDs (=B bytes) Ports LEDs for function #1 (=C bytes) Ports LEDs for function #2 (=C bytes) Ports LEDs for function #3 (=C bytes) ... Ports LEDs for function #D (=C bytes) The length of this item, with the current values, is 78 bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

meritageClockAdminStatus 1.3.6.1.4.1.81.32.4.1
enable or disable the clock sync daughter board. When disabled, the M-SPS will use its own internal clock.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

meritageClockReset 1.3.6.1.4.1.81.32.4.2
Setting the value of this attribute to ON causes a reset only to the Clock Sync daughter board and not to the M-SPS.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

meritageClockWTR 1.3.6.1.4.1.81.32.4.3
The value in seconds of Wait Time to Restore. The time the M-SPS software will wait before restoring a healthy higher priority timing source as the sync source. This is to prevent toggling between two sources if one source is intermittently bad. If the WTR is set to infinity, a higher priority source will be active only if the current source fails or after reset. ranges 10-3600 seconds value = 9999 means infinity. default value - 20 sec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

meritageClockStatus 1.3.6.1.4.1.81.32.4.4
The status of the Clock Sync daughter board: Locked - locked to the input timing source for more then 8 seconds. Holdover - Trying to simulate a clock it was previously locked to. FreeRunning - Outputting a timing source derived from none of the sources. Internal - Outputting the internal clock, because the clock sync is disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER locked(1), holdover(2), freeRunning(3), internal(4)  

meritageClockCurrentSource 1.3.6.1.4.1.81.32.4.5
The current clock source being used. This is the outcome of the status of the sources and the priority between the sources. possible values are: ATM A, ATM B, SYNC A, SYNC B, none (when there is no source, i.e. in Holdover, Free Running or Internal). A Trap will be sent on change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

meritageClockSourceTable 1.3.6.1.4.1.81.32.5.1
A table containing information about each clock source in the hub.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MeritageClockSourceEntry

meritageClockSourceEntry 1.3.6.1.4.1.81.32.5.1.1
An entry containing information about a particular clock source in the hub.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MeritageClockSourceEntry  

meritageClockSourceIndex 1.3.6.1.4.1.81.32.5.1.1.1
Index into this table, by clock source number 1-4. 1 - ATM A 2 - ATM B 3 - SYNC A 4 - SYNC B
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

meritageClockSourceStatus 1.3.6.1.4.1.81.32.5.1.1.2
The status of the source port ok - link ok los - loss of signal. failed - the source may have a link, but the M-SPS has failed 4 times to lock to it. The source will automatically be disabled (priority 0). The status can exit the failed status only if the user enables the source by raising it's priority.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), los(2), failed(3), notSupported(255)  

meritageClockSourcePriority 1.3.6.1.4.1.81.32.5.1.1.3
The priority of the source port 0 - disabled 1 - lowest 4 - highest
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4  

meritageClockSourceConfigPort 1.3.6.1.4.1.81.32.5.1.1.4
The port assigned to drive the Clock Source. In the format X.Y - where X & Y are integers: 1st byte (X) - Slot number 2nd byte - (.) 3rd byte (Y) - Port number The NMS can write values to index 1 and 2 only. Attempt to write a value to index 3 and 4 will cause genError. The NMS can read the value to see that the set was successful. For index 1 - for example = 3.1 For index 2 - for example = 3.2 For index 3 - value always = 15.1 For index 4 - value always = 15.2
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

meritageClockSourceFraming 1.3.6.1.4.1.81.32.5.1.1.5
The framing mode for the SYNC A SYNC B ports. Sources ATM A and ATM will reply with notSupported (255). For M-SPS/ER and EB, the values 1 and 2 are relevant. For M-SPS/T, the values 3 and 4 are relevant.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER e1-framed(1), e1-unframed(2), ds1-sf(3), ds1-esf(4), notSupported(255)