ME1200-SYNCE-MIB

File: ME1200-SYNCE-MIB.mib (26503 bytes)

Imported modules

SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
CISCOME1200-MIB ME1200-TC

Imported symbols

MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
TEXTUAL-CONVENTION me1200SwitchMgmt ME1200InterfaceIndex
ME1200Unsigned8 Integer32 Unsigned32
TruthValue

Defined Types

ME1200synceAnegMode  
TEXTUAL-CONVENTION    
  current INTEGER none(0), preferedSlave(1), preferedMaster(2), forcedSlave(3)

ME1200synceEecOption  
TEXTUAL-CONVENTION    
  current INTEGER eecOption1(0), eecOption2(1)

ME1200synceFrequency  
TEXTUAL-CONVENTION    
  current INTEGER disabled(0), freq1544kHz(1), freq2048kHz(2), freq10MHz(3), freqMax(4)

ME1200syncePtsfState  
TEXTUAL-CONVENTION    
  current INTEGER none(0), unusable(1), lossSync(2), lossAnnounce(3)

ME1200synceQualityLevel  
TEXTUAL-CONVENTION    
  current INTEGER qlNone(0), qlPrc(1), qlSsua(2), qlSsub(3), qlEec2(4), qlEec1(5), qlDnu(6), qlInv(7), qlFail(8), qlLink(9)

ME1200synceSelectionMode  
TEXTUAL-CONVENTION    
  current INTEGER manual(0), manualToSelected(1), autoNonrevertive(2), autoRevertive(3), forcedHoldover(4), forcedFreeRun(5)

ME1200synceSelectorState  
TEXTUAL-CONVENTION    
  current INTEGER locked(0), holdover(1), freerun(2), ptp(3), refFailed(4), acquiring(5)

ME1200SynceConfigSourcesClockSourceNominationEntry  
SEQUENCE    
  me1200SynceConfigSourcesClockSourceNominationSourceId Integer32
  me1200SynceConfigSourcesClockSourceNominationNominated TruthValue
  me1200SynceConfigSourcesClockSourceNominationNetworkPort ME1200InterfaceIndex
  me1200SynceConfigSourcesClockSourceNominationClkInPort ME1200Unsigned8
  me1200SynceConfigSourcesClockSourceNominationPriority Unsigned32
  me1200SynceConfigSourcesClockSourceNominationAnegMode ME1200synceAnegMode
  me1200SynceConfigSourcesClockSourceNominationSsmOverwrite ME1200synceQualityLevel
  me1200SynceConfigSourcesClockSourceNominationHoldoffTime Unsigned32

ME1200SynceConfigPortsPortConfigEntry  
SEQUENCE    
  me1200SynceConfigPortsPortConfigPortId ME1200InterfaceIndex
  me1200SynceConfigPortsPortConfigSsmEnabled TruthValue

ME1200SynceStatusSourcesClockSourceNominationEntry  
SEQUENCE    
  me1200SynceStatusSourcesClockSourceNominationSourceId Integer32
  me1200SynceStatusSourcesClockSourceNominationLocs TruthValue
  me1200SynceStatusSourcesClockSourceNominationFos TruthValue
  me1200SynceStatusSourcesClockSourceNominationSsm TruthValue
  me1200SynceStatusSourcesClockSourceNominationWtr TruthValue

ME1200SynceStatusPortsPortStatusEntry  
SEQUENCE    
  me1200SynceStatusPortsPortStatusPortId ME1200InterfaceIndex
  me1200SynceStatusPortsPortStatusSsmRx ME1200synceQualityLevel
  me1200SynceStatusPortsPortStatusSsmTx ME1200synceQualityLevel
  me1200SynceStatusPortsPortStatusMaster TruthValue

ME1200SynceStatusPtpPortStatusEntry  
SEQUENCE    
  me1200SynceStatusPtpPortStatusSourceId Integer32
  me1200SynceStatusPtpPortStatusSsmRx ME1200synceQualityLevel
  me1200SynceStatusPtpPortStatusPtsf ME1200syncePtsfState

ME1200SynceControlSourcesClockSourceEntry  
SEQUENCE    
  me1200SynceControlSourcesClockSourceSourceId Integer32
  me1200SynceControlSourcesClockSourceClearWtr ME1200Unsigned8

Defined Values

me1200SynceMib 1.3.6.1.4.1.9.9.815.1.42
Private SyncE MIB.
MODULE-IDENTITY    

me1200SynceMibObjects 1.3.6.1.4.1.9.9.815.1.42.1
OBJECT IDENTIFIER    

me1200SynceCapabilities 1.3.6.1.4.1.9.9.815.1.42.1.1
OBJECT IDENTIFIER    

me1200SynceCapabilitiesGlobal 1.3.6.1.4.1.9.9.815.1.42.1.1.1
OBJECT IDENTIFIER    

me1200SynceCapabilitiesGlobalSourceCount 1.3.6.1.4.1.9.9.815.1.42.1.1.1.1
The number of SyncE sources supported by the device.
OBJECT-TYPE    
  Unsigned32  

me1200SynceConfig 1.3.6.1.4.1.9.9.815.1.42.1.2
OBJECT IDENTIFIER    

me1200SynceConfigGlobal 1.3.6.1.4.1.9.9.815.1.42.1.2.1
OBJECT IDENTIFIER    

me1200SynceConfigGlobalClockSelectionMode 1.3.6.1.4.1.9.9.815.1.42.1.2.1.1
OBJECT IDENTIFIER    

me1200SynceConfigGlobalClockSelectionModeSelectionMode 1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.1
The selection mode.
OBJECT-TYPE    
  ME1200synceSelectionMode  

me1200SynceConfigGlobalClockSelectionModeSource 1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.2
Nominated source for manuel selection mode.
OBJECT-TYPE    
  Unsigned32  

me1200SynceConfigGlobalClockSelectionModeWtrTime 1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.3
WTR timer value in minutes. Range is 0 to 12 minutes where 0 means that the timer is disabled.
OBJECT-TYPE    
  Unsigned32  

me1200SynceConfigGlobalClockSelectionModeSsmHoldover 1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.4
Tx overwrite SSM used when clock controller is hold over.
OBJECT-TYPE    
  ME1200synceQualityLevel  

me1200SynceConfigGlobalClockSelectionModeSsmFreerun 1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.5
Tx overwrite SSM used when clock controller is free run.
OBJECT-TYPE    
  ME1200synceQualityLevel  

me1200SynceConfigGlobalClockSelectionModeEecOption 1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.6
Synchronous Ethernet Equipment Clock option.
OBJECT-TYPE    
  ME1200synceEecOption  

me1200SynceConfigGlobalStationClocks 1.3.6.1.4.1.9.9.815.1.42.1.2.1.2
OBJECT IDENTIFIER    

me1200SynceConfigGlobalStationClocksStationClkOut 1.3.6.1.4.1.9.9.815.1.42.1.2.1.2.1
Station clock output frequency setting.
OBJECT-TYPE    
  ME1200synceFrequency  

me1200SynceConfigGlobalStationClocksStationClkIn 1.3.6.1.4.1.9.9.815.1.42.1.2.1.2.2
Station clock input frequency setting.
OBJECT-TYPE    
  ME1200synceFrequency  

me1200SynceConfigSources 1.3.6.1.4.1.9.9.815.1.42.1.2.2
OBJECT IDENTIFIER    

me1200SynceConfigSourcesClockSourceNominationTable 1.3.6.1.4.1.9.9.815.1.42.1.2.2.1
This is the SyncE source nomination configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200SynceConfigSourcesClockSourceNominationEntry

me1200SynceConfigSourcesClockSourceNominationEntry 1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1
The sourceId index must be a value from 0 up to the number of sources minus one.
OBJECT-TYPE    
  ME1200SynceConfigSourcesClockSourceNominationEntry  

me1200SynceConfigSourcesClockSourceNominationSourceId 1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.1
-
OBJECT-TYPE    
  Integer32 0..32767  

me1200SynceConfigSourcesClockSourceNominationNominated 1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.2
Indicates if source is nominated.
OBJECT-TYPE    
  TruthValue  

me1200SynceConfigSourcesClockSourceNominationNetworkPort 1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.3
Interface index of the norminated source.
OBJECT-TYPE    
  ME1200InterfaceIndex  

me1200SynceConfigSourcesClockSourceNominationClkInPort 1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.4
Clock input of the norminated source.
OBJECT-TYPE    
  ME1200Unsigned8  

me1200SynceConfigSourcesClockSourceNominationPriority 1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.5
Priority of the nominated source.
OBJECT-TYPE    
  Unsigned32  

me1200SynceConfigSourcesClockSourceNominationAnegMode 1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.6
Autonogotiation mode auto-master-slave.
OBJECT-TYPE    
  ME1200synceAnegMode  

me1200SynceConfigSourcesClockSourceNominationSsmOverwrite 1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.7
SSM overwrite quality.
OBJECT-TYPE    
  ME1200synceQualityLevel  

me1200SynceConfigSourcesClockSourceNominationHoldoffTime 1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.8
Hold Off timer value in 100ms (3 - 18). Zero means no hold off.
OBJECT-TYPE    
  Unsigned32  

me1200SynceConfigPorts 1.3.6.1.4.1.9.9.815.1.42.1.2.3
OBJECT IDENTIFIER    

me1200SynceConfigPortsPortConfigTable 1.3.6.1.4.1.9.9.815.1.42.1.2.3.1
This is the SyncE port configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200SynceConfigPortsPortConfigEntry

me1200SynceConfigPortsPortConfigEntry 1.3.6.1.4.1.9.9.815.1.42.1.2.3.1.1
The portId index must be a value from 0 up to the number of ports minus one.
OBJECT-TYPE    
  ME1200SynceConfigPortsPortConfigEntry  

me1200SynceConfigPortsPortConfigPortId 1.3.6.1.4.1.9.9.815.1.42.1.2.3.1.1.1
-
OBJECT-TYPE    
  ME1200InterfaceIndex  

me1200SynceConfigPortsPortConfigSsmEnabled 1.3.6.1.4.1.9.9.815.1.42.1.2.3.1.1.2
Quality level via SSM enabled.
OBJECT-TYPE    
  TruthValue  

me1200SynceStatus 1.3.6.1.4.1.9.9.815.1.42.1.3
OBJECT IDENTIFIER    

me1200SynceStatusGlobal 1.3.6.1.4.1.9.9.815.1.42.1.3.1
OBJECT IDENTIFIER    

me1200SynceStatusGlobalClockSelectionMode 1.3.6.1.4.1.9.9.815.1.42.1.3.1.1
OBJECT IDENTIFIER    

me1200SynceStatusGlobalClockSelectionModeClockInput 1.3.6.1.4.1.9.9.815.1.42.1.3.1.1.1
The clock source locked to when clock selector is in locked state.
OBJECT-TYPE    
  Unsigned32  

me1200SynceStatusGlobalClockSelectionModeSelectorState 1.3.6.1.4.1.9.9.815.1.42.1.3.1.1.2
This is indicating the state of the clock selector.
OBJECT-TYPE    
  ME1200synceSelectorState  

me1200SynceStatusGlobalClockSelectionModeLosx 1.3.6.1.4.1.9.9.815.1.42.1.3.1.1.3
LOSX
OBJECT-TYPE    
  TruthValue  

me1200SynceStatusGlobalClockSelectionModeLol 1.3.6.1.4.1.9.9.815.1.42.1.3.1.1.4
Clock selector has raised the Los Of Lock alarm.
OBJECT-TYPE    
  TruthValue  

me1200SynceStatusGlobalClockSelectionModeDhold 1.3.6.1.4.1.9.9.815.1.42.1.3.1.1.5
Clock selector has not yet calculated the holdover frequency offset to local oscillator.
OBJECT-TYPE    
  TruthValue  

me1200SynceStatusSources 1.3.6.1.4.1.9.9.815.1.42.1.3.2
OBJECT IDENTIFIER    

me1200SynceStatusSourcesClockSourceNominationTable 1.3.6.1.4.1.9.9.815.1.42.1.3.2.1
This is the clock source nomination status.
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200SynceStatusSourcesClockSourceNominationEntry

me1200SynceStatusSourcesClockSourceNominationEntry 1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1
The sourceId index must be a value must be a value from 0 up to the number of sources minus one.
OBJECT-TYPE    
  ME1200SynceStatusSourcesClockSourceNominationEntry  

me1200SynceStatusSourcesClockSourceNominationSourceId 1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1.1
-
OBJECT-TYPE    
  Integer32 0..32767  

me1200SynceStatusSourcesClockSourceNominationLocs 1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1.2
LOCS
OBJECT-TYPE    
  TruthValue  

me1200SynceStatusSourcesClockSourceNominationFos 1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1.3
FOS
OBJECT-TYPE    
  TruthValue  

me1200SynceStatusSourcesClockSourceNominationSsm 1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1.4
SSM
OBJECT-TYPE    
  TruthValue  

me1200SynceStatusSourcesClockSourceNominationWtr 1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1.5
WTR
OBJECT-TYPE    
  TruthValue  

me1200SynceStatusPorts 1.3.6.1.4.1.9.9.815.1.42.1.3.3
OBJECT IDENTIFIER    

me1200SynceStatusPortsPortStatusTable 1.3.6.1.4.1.9.9.815.1.42.1.3.3.1
This is the port status.
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200SynceStatusPortsPortStatusEntry

me1200SynceStatusPortsPortStatusEntry 1.3.6.1.4.1.9.9.815.1.42.1.3.3.1.1
The portId index must be a value must be a value from 0 up to the number of ports minus one.
OBJECT-TYPE    
  ME1200SynceStatusPortsPortStatusEntry  

me1200SynceStatusPortsPortStatusPortId 1.3.6.1.4.1.9.9.815.1.42.1.3.3.1.1.1
-
OBJECT-TYPE    
  ME1200InterfaceIndex  

me1200SynceStatusPortsPortStatusSsmRx 1.3.6.1.4.1.9.9.815.1.42.1.3.3.1.1.2
Monitoring of the received SSM QL on this port.
OBJECT-TYPE    
  ME1200synceQualityLevel  

me1200SynceStatusPortsPortStatusSsmTx 1.3.6.1.4.1.9.9.815.1.42.1.3.3.1.1.3
Monitoring of the transmitted SSM QL on this port.
OBJECT-TYPE    
  ME1200synceQualityLevel  

me1200SynceStatusPortsPortStatusMaster 1.3.6.1.4.1.9.9.815.1.42.1.3.3.1.1.4
If PHY is in 1000BaseT Mode then this is monitoring the master/slave mode.
OBJECT-TYPE    
  TruthValue  

me1200SynceStatusPtp 1.3.6.1.4.1.9.9.815.1.42.1.3.4
OBJECT IDENTIFIER    

me1200SynceStatusPtpPortStatusTable 1.3.6.1.4.1.9.9.815.1.42.1.3.4.1
This is the PTP port status.
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200SynceStatusPtpPortStatusEntry

me1200SynceStatusPtpPortStatusEntry 1.3.6.1.4.1.9.9.815.1.42.1.3.4.1.1
The sourceId index must be a value must be a value from 0 up to the number of PTP sources minus one.
OBJECT-TYPE    
  ME1200SynceStatusPtpPortStatusEntry  

me1200SynceStatusPtpPortStatusSourceId 1.3.6.1.4.1.9.9.815.1.42.1.3.4.1.1.1
-
OBJECT-TYPE    
  Integer32 0..32767  

me1200SynceStatusPtpPortStatusSsmRx 1.3.6.1.4.1.9.9.815.1.42.1.3.4.1.1.2
Monitoring of the received SSM QL on this port.
OBJECT-TYPE    
  ME1200synceQualityLevel  

me1200SynceStatusPtpPortStatusPtsf 1.3.6.1.4.1.9.9.815.1.42.1.3.4.1.1.3
PTSF status for PTP source.
OBJECT-TYPE    
  ME1200syncePtsfState  

me1200SynceControl 1.3.6.1.4.1.9.9.815.1.42.1.4
OBJECT IDENTIFIER    

me1200SynceControlSources 1.3.6.1.4.1.9.9.815.1.42.1.4.1
OBJECT IDENTIFIER    

me1200SynceControlSourcesClockSourceTable 1.3.6.1.4.1.9.9.815.1.42.1.4.1.1
This is the SyncE sources control structure.
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200SynceControlSourcesClockSourceEntry

me1200SynceControlSourcesClockSourceEntry 1.3.6.1.4.1.9.9.815.1.42.1.4.1.1.1
The sourceId index must be a value must be a value from 0 up to the number of sources minus one.
OBJECT-TYPE    
  ME1200SynceControlSourcesClockSourceEntry  

me1200SynceControlSourcesClockSourceSourceId 1.3.6.1.4.1.9.9.815.1.42.1.4.1.1.1.1
-
OBJECT-TYPE    
  Integer32 0..32767  

me1200SynceControlSourcesClockSourceClearWtr 1.3.6.1.4.1.9.9.815.1.42.1.4.1.1.1.2
-
OBJECT-TYPE    
  ME1200Unsigned8  

me1200SynceNotificationPrefix 1.3.6.1.4.1.9.9.815.1.42.1.5
OBJECT IDENTIFIER    

me1200SynceNotification 1.3.6.1.4.1.9.9.815.1.42.1.5.0
OBJECT IDENTIFIER    

me1200SynceNotificationClockSelectorStateChange 1.3.6.1.4.1.9.9.815.1.42.1.5.0.1
Notification is sent when the clock selector state is changed.
NOTIFICATION-TYPE    

me1200SynceMibConformance 1.3.6.1.4.1.9.9.815.1.42.2
OBJECT IDENTIFIER    

me1200SynceMibCompliances 1.3.6.1.4.1.9.9.815.1.42.2.1
OBJECT IDENTIFIER    

me1200SynceMibGroups 1.3.6.1.4.1.9.9.815.1.42.2.2
OBJECT IDENTIFIER    

me1200SynceCapabilitiesGlobalInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.1
A collection of objects suitable for bulk operations.
OBJECT-GROUP    

me1200SynceConfigGlobalClockSelectionModeInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.2
A collection of objects suitable for bulk operations.
OBJECT-GROUP    

me1200SynceConfigGlobalStationClocksInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.3
A collection of objects suitable for bulk operations.
OBJECT-GROUP    

me1200SynceConfigSourcesClockSourceNominationInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.4
A collection of objects suitable for bulk operations.
OBJECT-GROUP    

me1200SynceConfigPortsPortConfigInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.5
A collection of objects suitable for bulk operations.
OBJECT-GROUP    

me1200SynceStatusGlobalClockSelectionModeInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.6
A collection of objects suitable for bulk operations.
OBJECT-GROUP    

me1200SynceStatusSourcesClockSourceNominationInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.7
A collection of objects suitable for bulk operations.
OBJECT-GROUP    

me1200SynceStatusPortsPortStatusInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.8
A collection of objects suitable for bulk operations.
OBJECT-GROUP    

me1200SynceStatusPtpPortStatusInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.9
A collection of objects suitable for bulk operations.
OBJECT-GROUP    

me1200SynceControlSourcesClockSourceInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.10
A collection of objects suitable for bulk operations.
OBJECT-GROUP    

me1200SynceNotificationInfoGroup 1.3.6.1.4.1.9.9.815.1.42.2.2.11
A collection of objects suitable for bulk operations.
NOTIFICATION-GROUP    

me1200SynceMibCompliance 1.3.6.1.4.1.9.9.815.1.42.2.1.1
The compliance statement for the implementation.
MODULE-COMPLIANCE