ME1200-ERPS-MIB

File: ME1200-ERPS-MIB.mib (42716 bytes)

Imported modules

SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
CISCOME1200-MIB ME1200-TC

Imported symbols

MODULE-COMPLIANCE OBJECT-GROUP MODULE-IDENTITY
OBJECT-TYPE TEXTUAL-CONVENTION me1200SwitchMgmt
ME1200InterfaceIndex ME1200RowEditorState ME1200VlanListQuarter
Counter64 Integer32 Unsigned32
TruthValue

Defined Types

ME1200ErpsAdminCmd  
Specifies the Administrative command.
TEXTUAL-CONVENTION    
  INTEGER manualSwitch(1), forcedSwitch(2), clear(3)  

ME1200ErpsControlCmd  
Specifies a control command.
TEXTUAL-CONVENTION    
  INTEGER none(0), admCmdForcedSwitch(1), admCmdManualSwitch(2), admCmdClear(3), statisticsClear(4)  

ME1200ErpsPort  
Specifies a particular logical ring port.
TEXTUAL-CONVENTION    
  INTEGER port0(1), port1(2)  

ME1200ErpsPortState  
Specifies the ring port state.
TEXTUAL-CONVENTION    
  INTEGER ok(1), signalFail(2)  

ME1200ErpsProtectionState  
Specifies the ring protection state.
TEXTUAL-CONVENTION    
  INTEGER none(1), idle(2), protected(3), forcedSwitch(4), manualSwitch(5), pending(6)  

ME1200ErpsRequestState  
Specifies a request/state.
TEXTUAL-CONVENTION    
  INTEGER none(1), manualSwitch(2), signalFail(3), forcedSwitch(4), event(5)  

ME1200ErpsRingType  
Specifies the ERPS ring type.
TEXTUAL-CONVENTION    
  INTEGER major(1), sub(2)  

ME1200ErpsRplMode  
Specifies the Ring Protection Link mode. Use 'none' if port is neither RPL owner nor neighbour.
TEXTUAL-CONVENTION    
  INTEGER none(1), owner(2), neighbour(3)  

ME1200ErpsVersion  
Specifies the ERPS protocol version.
TEXTUAL-CONVENTION    
  INTEGER version1(1), version2(2)  

ME1200ErpsConfigEntry  
SEQUENCE    
  me1200ErpsConfigGroupIndex Integer32
  me1200ErpsConfigRingType ME1200ErpsRingType
  me1200ErpsConfigPort0 ME1200InterfaceIndex
  me1200ErpsConfigPort1 ME1200InterfaceIndex
  me1200ErpsConfigInterconnectMajorRingGroupIndex Unsigned32
  me1200ErpsConfigVirtualChannel TruthValue
  me1200ErpsConfigPort0SignalFailMepIndex Unsigned32
  me1200ErpsConfigPort0ApsMepIndex Unsigned32
  me1200ErpsConfigPort1SignalFailMepIndex Unsigned32
  me1200ErpsConfigPort1ApsMepIndex Unsigned32
  me1200ErpsConfigHoldOffTime Unsigned32
  me1200ErpsConfigWaitToRestoreTime Unsigned32
  me1200ErpsConfigGuardTime Unsigned32
  me1200ErpsConfigRplMode ME1200ErpsRplMode
  me1200ErpsConfigRplPort ME1200ErpsPort
  me1200ErpsConfigRevertive TruthValue
  me1200ErpsConfigVersion ME1200ErpsVersion
  me1200ErpsConfigTopologyChange TruthValue
  me1200ErpsConfigProtectedVlans0Kto1K ME1200VlanListQuarter
  me1200ErpsConfigProtectedVlans1Kto2K ME1200VlanListQuarter
  me1200ErpsConfigProtectedVlans2Kto3K ME1200VlanListQuarter
  me1200ErpsConfigProtectedVlans3Kto4K ME1200VlanListQuarter
  me1200ErpsConfigAction ME1200RowEditorState

ME1200ErpsStatusEntry  
SEQUENCE    
  me1200ErpsStatusGroupIndex Integer32
  me1200ErpsStatusActive TruthValue
  me1200ErpsStatusProtectionState ME1200ErpsProtectionState
  me1200ErpsStatusRplBlocked TruthValue
  me1200ErpsStatusWtrRemaining Unsigned32
  me1200ErpsStatusAdminCmd ME1200ErpsAdminCmd
  me1200ErpsStatusFopAlarm TruthValue
  me1200ErpsStatusTxActive TruthValue
  me1200ErpsStatusTxRequestOrState ME1200ErpsRequestState
  me1200ErpsStatusTxRplBlocked TruthValue
  me1200ErpsStatusTxDoNotFlush TruthValue
  me1200ErpsStatusBlockedPortReference ME1200ErpsPort
  me1200ErpsStatusPort0Blocked TruthValue
  me1200ErpsStatusPort0State ME1200ErpsPortState
  me1200ErpsStatusPort0RxActive TruthValue
  me1200ErpsStatusPort0RxRequestOrState ME1200ErpsRequestState
  me1200ErpsStatusPort0RxRplBlocked TruthValue
  me1200ErpsStatusPort0RxDoNotFlush TruthValue
  me1200ErpsStatusPort0RxBlockedPortReference ME1200ErpsPort
  me1200ErpsStatusPort0RxNodeId OCTET STRING
  me1200ErpsStatusPort1Blocked TruthValue
  me1200ErpsStatusPort1State ME1200ErpsPortState
  me1200ErpsStatusPort1RxActive TruthValue
  me1200ErpsStatusPort1RxRequestOrState ME1200ErpsRequestState
  me1200ErpsStatusPort1RxRplBlocked TruthValue
  me1200ErpsStatusPort1RxDoNotFlush TruthValue
  me1200ErpsStatusPort1RxBlockedPortReference ME1200ErpsPort
  me1200ErpsStatusPort1RxNodeId OCTET STRING

ME1200ErpsStatisticsEntry  
SEQUENCE    
  me1200ErpsStatisticsGroupIndex Integer32
  me1200ErpsStatisticsRapsTx Counter64
  me1200ErpsStatisticsRapsRx Counter64
  me1200ErpsStatisticsRapsRxDrop Counter64
  me1200ErpsStatisticsLocalSF Counter64
  me1200ErpsStatisticsLocalSFCleared Counter64
  me1200ErpsStatisticsRemoteSF Counter64
  me1200ErpsStatisticsNR Counter64
  me1200ErpsStatisticsRemoteMS Counter64
  me1200ErpsStatisticsLocalMS Counter64
  me1200ErpsStatisticsRemoteFS Counter64
  me1200ErpsStatisticsLocalFS Counter64
  me1200ErpsStatisticsAdminClear Counter64

ME1200ErpsControlEntry  
SEQUENCE    
  me1200ErpsControlGroupIndex Integer32
  me1200ErpsControlCommand ME1200ErpsControlCmd
  me1200ErpsControlPort ME1200ErpsPort

Defined Values

me1200ErpsMib 1.3.6.1.4.1.9.9.815.1.72
Private MIB for Ethernet Ring Protection Switching, ERPS.
MODULE-IDENTITY    

me1200ErpsMIBObjects 1.3.6.1.4.1.9.9.815.1.72.1
OBJECT IDENTIFIER    

me1200ErpsCapabilities 1.3.6.1.4.1.9.9.815.1.72.1.1
OBJECT IDENTIFIER    

me1200ErpsCapabilitiesMaxGroups 1.3.6.1.4.1.9.9.815.1.72.1.1.1
Maximum number of configured ERPS groups.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

me1200ErpsCapabilitiesMaxVlansPerGroup 1.3.6.1.4.1.9.9.815.1.72.1.1.2
Maximum number of protected VLANS per ERPS group.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfig 1.3.6.1.4.1.9.9.815.1.72.1.2
OBJECT IDENTIFIER    

me1200ErpsConfigTable 1.3.6.1.4.1.9.9.815.1.72.1.2.1
This is the ERPS group configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200ErpsConfigEntry

me1200ErpsConfigEntry 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1
Each entry in this table represents an ERPS group.
Status: current Access: not-accessible
OBJECT-TYPE    
  ME1200ErpsConfigEntry  

me1200ErpsConfigGroupIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.1
ERPS group index number. Valid range is (1..max groups). The maximum group number is platform-specific and can be retrieved from the ERPS capabilities.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

me1200ErpsConfigRingType 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.2
Type of ring. Can only be set once for a ring instance.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200ErpsRingType  

me1200ErpsConfigPort0 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.3
ifindex of ring protection port 0. Can only be set once for a ring instance.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200InterfaceIndex  

me1200ErpsConfigPort1 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.4
ifindex of ring protection Port 1. For interconnected sub-rings this value must be zero. Can only be set once for a ring instance.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200InterfaceIndex  

me1200ErpsConfigInterconnectMajorRingGroupIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.5
For sub-ring: zero = not interconnected; > zero = index of major ring group. For major ring: zero = not interconnected; > zero = is interconnected (i.e flag-like semantics). Can only be set once for a ring instance.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigVirtualChannel 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.6
Whether to use a virtual channel. Can only be set once for a ring instance.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

me1200ErpsConfigPort0SignalFailMepIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.7
Index of SignalFail MEP for Port 0. Zero if not set. To clear an ERPS group's MEP association, set this to zero; it affects all MEP indices.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigPort0ApsMepIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.8
Index of APS MEP for Port 0. Zero if not set.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigPort1SignalFailMepIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.9
Index of SignalFail MEP for Port 1. Zero if not set. Must be zero for interconnected sub-rings.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigPort1ApsMepIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.10
Index of APS MEP for Port 1. Zero if not set. Must be zero for interconnected sub-rings with virtual channel.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigHoldOffTime 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.11
Hold off time in ms. Value is rounded down to 100ms precision. Valid range is 0-10000 ms
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigWaitToRestoreTime 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.12
Wait-to-Restore time in ms. Valid range is 60000-720000 ms (1-12 minutes).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigGuardTime 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.13
Guard time in ms. Valid range is 10-2000 ms.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigRplMode 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.14
Ring Protection Link mode.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200ErpsRplMode  

me1200ErpsConfigRplPort 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.15
RPL port. Only valid if the ERPS group is RPL owner or neighbour.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200ErpsPort  

me1200ErpsConfigRevertive 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.16
Revertive (true) or Non-revertive (false) mode.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

me1200ErpsConfigVersion 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.17
ERPS protocol version.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200ErpsVersion  

me1200ErpsConfigTopologyChange 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.18
Whether to enable Topology Change propagation; only valid for an interconnected node.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

me1200ErpsConfigProtectedVlans0Kto1K 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.19
First quarter of bit-array indicating whether a VLAN is protected by this ring instance ('1') or not ('0').
Status: current Access: read-write
OBJECT-TYPE    
  ME1200VlanListQuarter  

me1200ErpsConfigProtectedVlans1Kto2K 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.20
Second quarter of bit-array indicating whether a VLAN is protected by this ring instance ('1') or not ('0').
Status: current Access: read-write
OBJECT-TYPE    
  ME1200VlanListQuarter  

me1200ErpsConfigProtectedVlans2Kto3K 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.21
Third quarter of bit-array indicating whether a VLAN is protected by this ring instance ('1') or not ('0').
Status: current Access: read-write
OBJECT-TYPE    
  ME1200VlanListQuarter  

me1200ErpsConfigProtectedVlans3Kto4K 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.22
Fourth quarter of bit-array indicating whether a VLAN is protected by this ring instance ('1') or not ('0').
Status: current Access: read-write
OBJECT-TYPE    
  ME1200VlanListQuarter  

me1200ErpsConfigAction 1.3.6.1.4.1.9.9.815.1.72.1.2.1.1.100
Action
Status: current Access: read-write
OBJECT-TYPE    
  ME1200RowEditorState  

me1200ErpsConfigRowEditor 1.3.6.1.4.1.9.9.815.1.72.1.2.2
OBJECT IDENTIFIER    

me1200ErpsConfigRowEditorGroupIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.2.1
ERPS group index number. Valid range is (1..max groups). The maximum group number is platform-specific and can be retrieved from the ERPS capabilities.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

me1200ErpsConfigRowEditorRingType 1.3.6.1.4.1.9.9.815.1.72.1.2.2.2
Type of ring. Can only be set once for a ring instance.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200ErpsRingType  

me1200ErpsConfigRowEditorPort0 1.3.6.1.4.1.9.9.815.1.72.1.2.2.3
ifindex of ring protection port 0. Can only be set once for a ring instance.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200InterfaceIndex  

me1200ErpsConfigRowEditorPort1 1.3.6.1.4.1.9.9.815.1.72.1.2.2.4
ifindex of ring protection Port 1. For interconnected sub-rings this value must be zero. Can only be set once for a ring instance.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200InterfaceIndex  

me1200ErpsConfigRowEditorInterconnectMajorRingGroupIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.2.5
For sub-ring: zero = not interconnected; > zero = index of major ring group. For major ring: zero = not interconnected; > zero = is interconnected (i.e flag-like semantics). Can only be set once for a ring instance.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigRowEditorVirtualChannel 1.3.6.1.4.1.9.9.815.1.72.1.2.2.6
Whether to use a virtual channel. Can only be set once for a ring instance.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

me1200ErpsConfigRowEditorPort0SignalFailMepIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.2.7
Index of SignalFail MEP for Port 0. Zero if not set. To clear an ERPS group's MEP association, set this to zero; it affects all MEP indices.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigRowEditorPort0ApsMepIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.2.8
Index of APS MEP for Port 0. Zero if not set.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigRowEditorPort1SignalFailMepIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.2.9
Index of SignalFail MEP for Port 1. Zero if not set. Must be zero for interconnected sub-rings.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigRowEditorPort1ApsMepIndex 1.3.6.1.4.1.9.9.815.1.72.1.2.2.10
Index of APS MEP for Port 1. Zero if not set. Must be zero for interconnected sub-rings with virtual channel.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigRowEditorHoldOffTime 1.3.6.1.4.1.9.9.815.1.72.1.2.2.11
Hold off time in ms. Value is rounded down to 100ms precision. Valid range is 0-10000 ms
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigRowEditorWaitToRestoreTime 1.3.6.1.4.1.9.9.815.1.72.1.2.2.12
Wait-to-Restore time in ms. Valid range is 60000-720000 ms (1-12 minutes).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigRowEditorGuardTime 1.3.6.1.4.1.9.9.815.1.72.1.2.2.13
Guard time in ms. Valid range is 10-2000 ms.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200ErpsConfigRowEditorRplMode 1.3.6.1.4.1.9.9.815.1.72.1.2.2.14
Ring Protection Link mode.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200ErpsRplMode  

me1200ErpsConfigRowEditorRplPort 1.3.6.1.4.1.9.9.815.1.72.1.2.2.15
RPL port. Only valid if the ERPS group is RPL owner or neighbour.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200ErpsPort  

me1200ErpsConfigRowEditorRevertive 1.3.6.1.4.1.9.9.815.1.72.1.2.2.16
Revertive (true) or Non-revertive (false) mode.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

me1200ErpsConfigRowEditorVersion 1.3.6.1.4.1.9.9.815.1.72.1.2.2.17
ERPS protocol version.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200ErpsVersion  

me1200ErpsConfigRowEditorTopologyChange 1.3.6.1.4.1.9.9.815.1.72.1.2.2.18
Whether to enable Topology Change propagation; only valid for an interconnected node.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

me1200ErpsConfigRowEditorProtectedVlans0Kto1K 1.3.6.1.4.1.9.9.815.1.72.1.2.2.19
First quarter of bit-array indicating whether a VLAN is protected by this ring instance ('1') or not ('0').
Status: current Access: read-write
OBJECT-TYPE    
  ME1200VlanListQuarter  

me1200ErpsConfigRowEditorProtectedVlans1Kto2K 1.3.6.1.4.1.9.9.815.1.72.1.2.2.20
Second quarter of bit-array indicating whether a VLAN is protected by this ring instance ('1') or not ('0').
Status: current Access: read-write
OBJECT-TYPE    
  ME1200VlanListQuarter  

me1200ErpsConfigRowEditorProtectedVlans2Kto3K 1.3.6.1.4.1.9.9.815.1.72.1.2.2.21
Third quarter of bit-array indicating whether a VLAN is protected by this ring instance ('1') or not ('0').
Status: current Access: read-write
OBJECT-TYPE    
  ME1200VlanListQuarter  

me1200ErpsConfigRowEditorProtectedVlans3Kto4K 1.3.6.1.4.1.9.9.815.1.72.1.2.2.22
Fourth quarter of bit-array indicating whether a VLAN is protected by this ring instance ('1') or not ('0').
Status: current Access: read-write
OBJECT-TYPE    
  ME1200VlanListQuarter  

me1200ErpsConfigRowEditorAction 1.3.6.1.4.1.9.9.815.1.72.1.2.2.100
Action
Status: current Access: read-write
OBJECT-TYPE    
  ME1200RowEditorState  

me1200ErpsStatus 1.3.6.1.4.1.9.9.815.1.72.1.3
OBJECT IDENTIFIER    

me1200ErpsStatusTable 1.3.6.1.4.1.9.9.815.1.72.1.3.1
This table contains status per EPRS group.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200ErpsStatusEntry

me1200ErpsStatusEntry 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1
Status.
Status: current Access: not-accessible
OBJECT-TYPE    
  ME1200ErpsStatusEntry  

me1200ErpsStatusGroupIndex 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.1
ERPS group index number. Valid range is (1..max groups). The maximum group number is platform-specific and can be retrieved from the ERPS capabilities.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

me1200ErpsStatusActive 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.2
Specifies whether ERPS group is currently active or not.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusProtectionState 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.3
Specifies current ERPS group protection state.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200ErpsProtectionState  

me1200ErpsStatusRplBlocked 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.4
Specifies whether the RPL is currently blocked or not.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusWtrRemaining 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.5
Specifies the remaining wait-time before restoring ring.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

me1200ErpsStatusAdminCmd 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.6
Specifies the currently active administrative command.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200ErpsAdminCmd  

me1200ErpsStatusFopAlarm 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.7
Specifies whether the FailureOfProtocol alarm is currently active or not.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusTxActive 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.8
Specifies whether R-APS transmission is currently active.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusTxRequestOrState 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.9
Specifies the currently transmitted request/state. Only relevant when Tx is active.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200ErpsRequestState  

me1200ErpsStatusTxRplBlocked 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.10
Specifies the currently transmitted RPL Blocked flag. Only relevant when Tx is active.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusTxDoNotFlush 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.11
Specifies the currently transmitted Do Not Flush flag. Only relevant when Tx is active.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusBlockedPortReference 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.12
Specifies the currently transmitted Blocked Port Reference. Only relevant when Tx is active.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200ErpsPort  

me1200ErpsStatusPort0Blocked 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.13
Specifies whether ring Port 0 is blocked or not.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusPort0State 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.14
Specifies the state of ring Port 0.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200ErpsPortState  

me1200ErpsStatusPort0RxActive 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.15
Specifies if ring Port0 receives R-APS.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusPort0RxRequestOrState 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.16
Specifies the most recently received request/state on ring Port 0. Only relevant when Rx is active.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200ErpsRequestState  

me1200ErpsStatusPort0RxRplBlocked 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.17
Specifies the most recently received RPL Blocked flag on ring Port 0. Only relevant when Rx is active.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusPort0RxDoNotFlush 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.18
Specifies the most recently received Do Not Flush flag on ring Port 0. Only relevant when Rx is active.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusPort0RxBlockedPortReference 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.19
Specifies the most recently received Blocked Port Reference on ring Port 0. Only relevant when Rx is active.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200ErpsPort  

me1200ErpsStatusPort0RxNodeId 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.20
Specifies the most recently received node ID on ring Port 0. Only relevant when Rx is active.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

me1200ErpsStatusPort1Blocked 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.21
Specifies whether ring Port 1 is blocked or not.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusPort1State 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.22
Specifies the state of ring Port 1.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200ErpsPortState  

me1200ErpsStatusPort1RxActive 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.23
Specifies if ring Port1 receives R-APS.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusPort1RxRequestOrState 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.24
Specifies the most recently received request/state on ring Port 1. Only relevant when Rx is active.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200ErpsRequestState  

me1200ErpsStatusPort1RxRplBlocked 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.25
Specifies the most recently received RPL Blocked flag on ring Port 1. Only relevant when Rx is active.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusPort1RxDoNotFlush 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.26
Specifies the most recently received Do Not Flush flag on ring Port 1. Only relevant when Rx is active.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

me1200ErpsStatusPort1RxBlockedPortReference 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.27
Specifies the most recently received Blocked Port Reference on ring Port 1. Only relevant when Rx is active.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200ErpsPort  

me1200ErpsStatusPort1RxNodeId 1.3.6.1.4.1.9.9.815.1.72.1.3.1.1.28
Specifies the most recently received node ID on ring Port 1. Only relevant when Rx is active.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

me1200ErpsStatistics 1.3.6.1.4.1.9.9.815.1.72.1.4
OBJECT IDENTIFIER    

me1200ErpsStatisticsTable 1.3.6.1.4.1.9.9.815.1.72.1.4.1
This table contains statistics per EPRS group.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200ErpsStatisticsEntry

me1200ErpsStatisticsEntry 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1
Various PDU and event counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  ME1200ErpsStatisticsEntry  

me1200ErpsStatisticsGroupIndex 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.1
ERPS group index number. Valid range is (1..max groups). The maximum group number is platform-specific and can be retrieved from the ERPS capabilities.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

me1200ErpsStatisticsRapsTx 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.2
Number of transmitted RAPS PDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsRapsRx 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.3
Number of received RAPS PDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsRapsRxDrop 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.4
Number of received RAPS PDUs that were dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsLocalSF 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.5
Number of local SignalFail events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsLocalSFCleared 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.6
Number of local SignalFail clear events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsRemoteSF 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.7
Number of remote SignalFail events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsNR 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.8
Number of NoRequest events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsRemoteMS 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.9
Number of remote ManualSwitch events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsLocalMS 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.10
Number of local ManualSwitch events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsRemoteFS 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.11
Number of remote ForcedSwitch events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsLocalFS 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.12
Number of local ForcedSwitch events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsStatisticsAdminClear 1.3.6.1.4.1.9.9.815.1.72.1.4.1.1.13
Number of AdminClear events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

me1200ErpsControl 1.3.6.1.4.1.9.9.815.1.72.1.5
OBJECT IDENTIFIER    

me1200ErpsControlTable 1.3.6.1.4.1.9.9.815.1.72.1.5.1
This is the ERPS group control table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200ErpsControlEntry

me1200ErpsControlEntry 1.3.6.1.4.1.9.9.815.1.72.1.5.1.1
Each entry in this table represents dynamic control elements an ERPS group.
Status: current Access: not-accessible
OBJECT-TYPE    
  ME1200ErpsControlEntry  

me1200ErpsControlGroupIndex 1.3.6.1.4.1.9.9.815.1.72.1.5.1.1.1
ERPS group index number. Valid range is (1..max groups). The maximum group number is platform-specific and can be retrieved from the ERPS capabilities.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

me1200ErpsControlCommand 1.3.6.1.4.1.9.9.815.1.72.1.5.1.1.2
Control command to execute. Always returns none when read.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200ErpsControlCmd  

me1200ErpsControlPort 1.3.6.1.4.1.9.9.815.1.72.1.5.1.1.3
Ring port affected by control command. Only relevant for administrative commands. Always returns port0 when read.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200ErpsPort  

me1200ErpsMIBConformance 1.3.6.1.4.1.9.9.815.1.72.2
OBJECT IDENTIFIER    

me1200ErpsMIBCompliances 1.3.6.1.4.1.9.9.815.1.72.2.1
OBJECT IDENTIFIER    

me1200ErpsMIBGroups 1.3.6.1.4.1.9.9.815.1.72.2.2
OBJECT IDENTIFIER    

me1200ErpsCapabilitiesInfoGroup 1.3.6.1.4.1.9.9.815.1.72.2.2.1
A collection of objects suitable for bulk operations.
Status: current Access: read-write
OBJECT-GROUP    

me1200ErpsConfigTableInfoGroup 1.3.6.1.4.1.9.9.815.1.72.2.2.2
A collection of objects suitable for bulk operations.
Status: current Access: read-write
OBJECT-GROUP    

me1200ErpsConfigRowEditorInfoGroup 1.3.6.1.4.1.9.9.815.1.72.2.2.3
A collection of objects suitable for bulk operations.
Status: current Access: read-write
OBJECT-GROUP    

me1200ErpsStatusTableInfoGroup 1.3.6.1.4.1.9.9.815.1.72.2.2.4
A collection of objects suitable for bulk operations.
Status: current Access: read-write
OBJECT-GROUP    

me1200ErpsStatisticsTableInfoGroup 1.3.6.1.4.1.9.9.815.1.72.2.2.5
A collection of objects suitable for bulk operations.
Status: current Access: read-write
OBJECT-GROUP    

me1200ErpsControlTableInfoGroup 1.3.6.1.4.1.9.9.815.1.72.2.2.6
A collection of objects suitable for bulk operations.
Status: current Access: read-write
OBJECT-GROUP    

me1200ErpsMibCompliance 1.3.6.1.4.1.9.9.815.1.72.2.1.1
The compliance statement for the implementation.
Status: current Access: read-write
MODULE-COMPLIANCE