MC2350-MIB

File: MC2350-MIB.mib (233775 bytes)

Imported modules

SNMPv2-TC RFC1155-SMI RFC-1212
SNMPv2-SMI RFC1213-MIB HOST-RESOURCES-MIB

Imported symbols

TEXTUAL-CONVENTION TimeTicks enterprises
NetworkAddress IpAddress Counter
DateAndTime OBJECT-TYPE Counter32
Integer32 DisplayString PhysAddress
hrDeviceIndex

Defined Types

CodedCharSet  
A coded character set value that specifies both a set of characters that may be used and an encoding (as one or more octets) that is used to represent the characters in the set. These values are to be used to identify the encoding employed for strings in the MIB where this is not fixed by the MIB.
TEXTUAL-CONVENTION    
  INTEGER other(1)  

MltPrtCommandEntry  
SEQUENCE    
  mltPrtCommandOnline INTEGER
  mltPrtCommandJobCancel INTEGER
  mltPrtCommandJobProceed INTEGER

MltPrtPrintPageEntry  
SEQUENCE    
  mltPrtPrintPageIndex INTEGER
  mltPrtPrintPageName DisplayString
  mltPrtPrintCommand INTEGER

MltPrtSysConfigEntry  
SEQUENCE    
  mltPrtJobLanguage INTEGER
  mltPrtPowerSave INTEGER
  mltPrtAutoContinue INTEGER
  mltPrtPaperTimeOut INTEGER
  mltPrtPsErrorPrint INTEGER

MltPrtPrintConfigEntry  
SEQUENCE    
  mltPrtCopies INTEGER
  mltPrtPaperSize INTEGER
  mltPrtPaperSource INTEGER
  mltPrtFineArt INTEGER
  mltPrtTonerSave INTEGER

MltPrtPclFontEntry  
SEQUENCE    
  mltPrtPclFontIndex INTEGER
  mltPrtPclFontName DisplayString
  mltPrtPclFontNumber INTEGER
  mltPrtPclFontSource INTEGER

MltPrtPsFontEntry  
SEQUENCE    
  mltPrtPsFontIndex INTEGER
  mltPrtPsFontName DisplayString
  mltPrtPsFontNumber INTEGER
  mltPrtPsFontSource INTEGER

MltPrtSymbolSetEntry  
SEQUENCE    
  mltPrtSymbolSetIndex INTEGER
  mltPrtSymbolSetName DisplayString
  mltPrtCharSetID INTEGER

MltPrtPaperSizeEntry  
SEQUENCE    
  mltPaperSizeIndex INTEGER
  mltPaperSizeName DisplayString
  mltPaperFeedDir INTEGER

MltPrtRemotePanelButtonEntry  
SEQUENCE    
  mltPrtPanelButtonIndex INTEGER
  mltPrtPanelButtonName DisplayString
  mltPrtPanelButtonPush INTEGER
  mltPrtPanelButtonDescr DisplayString

MltSysVersionEntry  
SEQUENCE    
  mltSysVersionIndex INTEGER
  mltSysVerName DisplayString
  mltSysVersionCode DisplayString
  mltSysVerDescr DisplayString

MltSysInputTrayEntry  
SEQUENCE    
  mltSysInputTrayIndex INTEGER
  mltSysInputTrayRefIndex INTEGER
  mltSysInputTrayName DisplayString
  mltSysInputTrayCapacitySence INTEGER
  mltSysInputTraySpecialPaper INTEGER
  mltSysInputTrayPaperAttribute INTEGER

MltSysOutputTrayEntry  
SEQUENCE    
  mltSysOutputTrayIndex INTEGER
  mltSysOutputTrayRefIndex INTEGER
  mltSysOutputTrayDefaultName DisplayString
  mltSysOutputTrayNickName DisplayString
  mltSysOutputTrayType INTEGER

MltSysPrintFunctionCounterEntry  
SEQUENCE    
  mltSysPrintFunctionColorIndex INTEGER
  mltSysPrintFunctionIndex INTEGER
  mltSysPrintFunctionColorType INTEGER
  mltSysPrintFunctionType INTEGER
  mltSysPrintFunctionTotalCount Integer32
  mltSysPrintFunctionDuplexCount Integer32
  mltSysPrintFunctionLargeSizeCount Integer32
  mltSysPrintFunctionLargeDuplexCount Integer32

MltSysSizeCounterEntry  
SEQUENCE    
  mltSysSizeFunctionIndex INTEGER
  mltSysSizeTypeIndex INTEGER
  mltSysSizeFunction INTEGER
  mltSysSizeType INTEGER
  mltSysSizeCount Integer32

MltSysTonerLifeCounterEntry  
SEQUENCE    
  mltSysTonerTypeIndex INTEGER
  mltSysTonerType INTEGER
  mltTonerTypeCount Counter32

MltNetGeneralEntry  
SEQUENCE    
  mltNetGeneralIndex INTEGER
  mltNetFirmVersion DisplayString
  mltNetHardwareAddress PhysAddress
  mltNetSerialNumber DisplayString
  mltNetSupportedConnector INTEGER
  mltNetCurrentConnector INTEGER
  mltNetSpeedConfig INTEGER
  mltNetInterfaceType INTEGER
  mltNetIfDescr DisplayString

MltNetProtocolEntry  
SEQUENCE    
  mltNetProtocolIfIndex INTEGER
  mltNetProtocolIndex INTEGER
  mltNetProtocolType INTEGER
  mltNetProtocolDescr DisplayString
  mltNetProtocolVer DisplayString
  mltNetProtocolOnOff INTEGER

MltNetCommandEntry  
SEQUENCE    
  mltNetCommandIfIndex INTEGER
  mltNetCommandReset INTEGER
  mltNetCommandDefault INTEGER
  mltNetCommandPrintNicConfig INTEGER
  mltNetCommandStartupConfig INTEGER
  mltNetCommandDownLoad INTEGER

MltNetSnmpCommEntry  
SEQUENCE    
  mltNetSnmpCommIndex INTEGER
  mltNetSnmpCommName DisplayString
  mltNetSnmpCommAccessRight INTEGER

MltNetSnmpTrapEntry  
SEQUENCE    
  mltNetSnmpTrapIfIndex INTEGER
  mltNetSnmpTrapIndex INTEGER
  mltNetSnmpTrapCommunity DisplayString
  mltNetSnmpTrapIpAddress IpAddress
  mltNetSnmpTrapIpxAddress DisplayString
  mltNetSnmpTrapOnOff INTEGER

MltNetTcpipGeneralEntry  
SEQUENCE    
  mltNetTcpipIfIndex INTEGER
  mltNetTcpipDefault INTEGER
  mltNetTcpipAddress IpAddress
  mltNetTcpipSubnet IpAddress
  mltNetTcpipGateway IpAddress
  mltNetTcpipUseBootProtocol INTEGER
  mltNetTcpipBootProtocolEnable INTEGER
  mltNetTcpipAddressServer IpAddress
  mltNetTcpipRawPortNumber INTEGER
  mltNetTcpipSupportService INTEGER
  mltNetTcpipDnsSupport INTEGER
  mltNetTcpipDnsHostName DisplayString
  mltNetTcpipDnsDomainName DisplayString

MltNetTcpipDnsEntry  
SEQUENCE    
  mltNetTcpipDnsIfIndex INTEGER
  mltNetTcpipDnsServerIndex INTEGER
  mltNetTcpipDnsServerAddress IpAddress

MltNetLpdGeneralEntry  
SEQUENCE    
  mltNetLpdIfIndex INTEGER
  mltNetLpdEnable INTEGER
  mltNetLpdPort INTEGER

MltNetLpdQueueEntry  
SEQUENCE    
  mltNetLpdQueueIfIndex INTEGER
  mltNetLpdQueueIndex INTEGER
  mltNetLpdQueueName DisplayString
  mltNetLpdQueueDescr DisplayString
  mltNetLpdQueueFilter INTEGER
  mltNetLpdQueueBanner INTEGER
  mltNetLpdQueueEnable INTEGER

MltNetFtpdGeneralEntry  
SEQUENCE    
  mltNetFtpdIfIndex INTEGER
  mltNetFtpdEnable INTEGER
  mltNetFtpdPort INTEGER

MltNetFtpdConfigEntry  
SEQUENCE    
  mltNetFtpdConfigIfIndex INTEGER
  mltNetFtpdUserIndex INTEGER
  mltNetFtpdUser DisplayString
  mltNetFtpdUserPassWd DisplayString
  mltNetFtpdCapability INTEGER
  mltNetFtpdDescr DisplayString

MltNetHttpdGeneralEntry  
SEQUENCE    
  mltNetHttpdIfIndex INTEGER
  mltNetHttpdEnable INTEGER
  mltNetHttpdPort INTEGER
  mltNetHttpdDescr DisplayString

MltNetSmtpGeneralEntry  
SEQUENCE    
  mltNetSmtpIfIndex INTEGER
  mltNetSmtpEnable INTEGER
  mltNetSmtpServerAddress DisplayString
  mltNetSmtpPort INTEGER

MltNetSmtpAccountEntry  
SEQUENCE    
  mltNetSmtpAccountIfIndex INTEGER
  mltNetSmtpAccountIndex INTEGER
  mltNetSmtpFromAddress DisplayString
  mltNetSmtpReplyAddress DisplayString
  mltNetSmtpConnTimeout INTEGER
  mltNetSmtpPurpose INTEGER
  mltNetSmtpDescription DisplayString

MltNetIppGeneralEntry  
SEQUENCE    
  mltNetIppGeneralIfIndex INTEGER
  mltNetIppServiceEnable INTEGER
  mltNetIppDefaultPortIndex INTEGER

MltNetIppPortEntry  
SEQUENCE    
  mltNetIppPortIfIndex INTEGER
  mltNetIppPortIndex INTEGER
  mltNetIppPortNumber INTEGER

MltNetIppPrtDescGeneralEntry  
SEQUENCE    
  mltIppPrtDescGeneralIfIndex INTEGER
  mltIppPrtName DisplayString
  mltIppPrtMoreInfo DisplayString
  mltIppPrtState INTEGER
  mltIppCharSetConfiguredIndex INTEGER
  mltIppNaturalLanguageConfiguredIndex INTEGER
  mltIppDocFormatDefaultIndex INTEGER
  mltIppPrinterIsAcceptingJobs INTEGER
  mltIppQueuedJobCount Counter
  mltIppColorSupported INTEGER
  mltIppPdlOverrideSupported INTEGER
  mltIppPrinterUpTime TimeTicks
  mltIppPrtLocation DisplayString
  mltIppPrinterCurrentTime DateAndTime

MltIppUriSupportedEntry  
SEQUENCE    
  mltIppUriIfIndex INTEGER
  mltIppUriIndex INTEGER
  mltIppUri DisplayString
  mltIppUriSecurity INTEGER
  mltIppUriAuthentication INTEGER

MltIppPrtStateReasonsEntry  
SEQUENCE    
  mltIppPrtStateReasonIfIndex INTEGER
  mltIppPrtStateReasonIndex INTEGER
  mltIppPrinterStateReason INTEGER
  mltIppPrtStateReasonSuffix INTEGER

MltIppVersionsSupportedEntry  
SEQUENCE    
  mltIppVersionIfIndex INTEGER
  mltIppVersionIndex INTEGER
  mltIppVersionType INTEGER

MltIppOperationSupportedEntry  
SEQUENCE    
  mltIppOperationIfIndex INTEGER
  mltIppOperationIndex INTEGER
  mltIppOperationType INTEGER
  mltIppOperationEnable INTEGER

MltIppCharSetSupportedEntry  
SEQUENCE    
  mltIppCharSetIfIndex INTEGER
  mltIppCharSetIndex INTEGER
  mltIppCharSetName DisplayString
  mltIppCharSetCode INTEGER

MltIppNaturalLanguageSupportedEntry  
SEQUENCE    
  mltIppNaturalLangIfIndex INTEGER
  mltIppNaturalLangIndex INTEGER
  mltIppNaturalLangName DisplayString

MltIppDocFormatSupportedEntry  
SEQUENCE    
  mltIppDocFormatIfIndex INTEGER
  mltIppDocFormatIndex INTEGER
  mltIppDocFormatName DisplayString

MltIppCompressionSupportedEntry  
SEQUENCE    
  mltIppCompressionIfIndex INTEGER
  mltIppCompressionIndex INTEGER
  mltIppCompressionType INTEGER

MltNetIppJobTemplateGeneralEntry  
SEQUENCE    
  mltIppJobTemplateGeneralIfIndex INTEGER
  mltIppJobPriorityDefault INTEGER
  mltIppJobPrioritySupported INTEGER
  mltIppJobHoldUntilDefault INTEGER
  mltIppJobSheetsDefault INTEGER
  mltIppCopiesDefault INTEGER
  mltIppCopiesMaxSupported INTEGER
  mltIppFinishingsDefault INTEGER
  mltIppPageRangesSupported INTEGER
  mltIppSidesDefault INTEGER
  mltIppNumberUpDefault INTEGER
  mltIppOrientationRequestedDefault INTEGER
  mltIppMediaDefault INTEGER
  mltIppPrinterResolutionDefault INTEGER
  mltIppPrintQualityDefault INTEGER

MltIppJobHoldUntilSupportedEntry  
SEQUENCE    
  mltIppJobHoldUntilIfIndex INTEGER
  mltIppJobHoldUntilIndex INTEGER
  mltIppJobHoldUntilType INTEGER

MltIppJobSheetsSupportedEntry  
SEQUENCE    
  mltIppJobSheetsIfIndex INTEGER
  mltIppJobSheetsIndex INTEGER
  mltIppJobSheetsType INTEGER

MltIppFinishingsSupportedEntry  
SEQUENCE    
  mltIppFinishingsIfIndex INTEGER
  mltIppFinishingsIndex INTEGER
  mltIppFinishingsType INTEGER

MltIppSidesSupportedEntry  
SEQUENCE    
  mltIppSidesIfIndex INTEGER
  mltIppSidesIndex INTEGER
  mltIppSidesType INTEGER

MltIppNumberUpSupportedEntry  
SEQUENCE    
  mltIppNumberUpIfIndex INTEGER
  mltIppNumberUpIndex INTEGER
  mltIppNumberUpType INTEGER

MltIppOrientationRequestedSupportedEntry  
SEQUENCE    
  mltIppOrientationRequestedIfIndex INTEGER
  mltIppOrientationRequestedIndex INTEGER
  mltIppOrientationRequestedType INTEGER

MltIppMediaSupportedEntry  
SEQUENCE    
  mltIppMediaIfIndex INTEGER
  mltIppMediaIndex INTEGER
  mltIppMediaName OCTET STRING
  mltIppMediaType OCTET STRING
  mltIppMediaColor OCTET STRING
  mltIppMediaInputTray OCTET STRING

MltPrinterResolutionSupportedEntry  
SEQUENCE    
  mltPrinterResolutionIfIndex INTEGER
  mltPrinterResolutionIndex INTEGER
  mltPrinterResolutionFeedDir Integer32
  mltPrinterResolutionXFeedDir Integer32
  mltPrinterResolutionUnit INTEGER

MltPrintQualitySupportedEntry  
SEQUENCE    
  mltPrintQualityIfIndex INTEGER
  mltPrintQualityIndex INTEGER
  mltPrintQualityType INTEGER

MltNetSlpGeneralEntry  
SEQUENCE    
  mltNetSlpIfIndex INTEGER
  mltNetSlpEnable INTEGER
  mltNetSlpPortNumber INTEGER
  mltNetSlpMTU INTEGER
  mltNetSlpTTL INTEGER
  mltNetSlpBroadcastSupport INTEGER

MltNetSlpConfigEntry  
SEQUENCE    
  mltNetSlpConfigIfIndex INTEGER
  mltNetSlpIndex INTEGER
  mltNetSlpService DisplayString
  mltNetSlpScope DisplayString
  mltNetSlpLifetime INTEGER

MltNetNwGeneralEntry  
SEQUENCE    
  mltNetNwIfIndex INTEGER
  mltNetNwDefault INTEGER
  mltNetNwFrameTypeConfig INTEGER
  mltNetNwPrintMode INTEGER

MltNetNwFrameEntry  
SEQUENCE    
  mltNetNwFrameIfIndex INTEGER
  mltNetNwFrameIndex INTEGER
  mltNetNwFrameType INTEGER
  mltNetNwNetworkNumber OCTET STRING

MltNetNwPserverEntry  
SEQUENCE    
  mltNetNwPsIfIndex INTEGER
  mltNetNwPsIndex INTEGER
  mltNetNwPsName DisplayString
  mltNetNwPsPasswd DisplayString
  mltNetNwPsMode INTEGER
  mltNetNwPsPrefFServer DisplayString
  mltNetNwPsPrefTree DisplayString
  mltNetNwPsPrefContext DisplayString
  mltNetNwPsPollingRate INTEGER

MltNetNwQueueEntry  
SEQUENCE    
  mltNetNwQueueIndex INTEGER
  mltNetNwQueueName DisplayString
  mltNetNwQueueRefIfIndex INTEGER
  mltNetNwQueueRefPsIndex INTEGER
  mltNetNwQueueStatus INTEGER

MltNetNwNPrinterEntry  
SEQUENCE    
  mltNetNwNPrinterIfIndex INTEGER
  mltNetNwNPrinterIndex INTEGER
  mltNetNwNPrinterName DisplayString
  mltNetNwNPrinterNumber INTEGER

MltNetAppleTalkGeneralEntry  
SEQUENCE    
  mltNetAtIfIndex INTEGER
  mltNetAtDefault INTEGER
  mltNetAtNetNumber INTEGER
  mltNetAtNodeNumber INTEGER
  mltNetAtDesiredZone DisplayString
  mltNetAtCurrentZone DisplayString

MltNetAtPrinterEntry  
SEQUENCE    
  mltNetAtPrinterIfIndex INTEGER
  mltNetAtPrinterIndex INTEGER
  mltNetAtPrinterName DisplayString
  mltNetAtPrinterType DisplayString

MltNetSmbGeneralEntry  
SEQUENCE    
  mltNetSmbIfIndex INTEGER
  mltNetSmbDefault INTEGER
  mltNetSmbWorkGroupName DisplayString
  mltNetSmbHostName DisplayString
  mltNetSmbWinsSupport INTEGER
  mltNetSmbWinsPrimaryServer IpAddress
  mltNetSmbWinsSecondaryServer IpAddress

MltNetSmbPrinterEntry  
SEQUENCE    
  mltNetSmbPrinterIfIndex INTEGER
  mltNetSmbPrinterIndex INTEGER
  mltNetSmbPrinterName DisplayString
  mltNetSmbPrinterDescr DisplayString

MltJmGeneralEntry  
SEQUENCE    
  mltJmGeneralJobSetIndex INTEGER
  mltJmGeneralNumberOfActiveJobs INTEGER
  mltJmGeneralOldestActiveJobIndex INTEGER
  mltJmGeneralNewestActiveJobIndex INTEGER
  mltJmGeneralJobPersistence INTEGER
  mltJmGeneralJobSetType INTEGER

MltJmJobEntry  
SEQUENCE    
  mltJmJobJobSetIndex INTEGER
  mltJmJobIndex INTEGER
  mltJmJobFunction INTEGER
  mltJmJobStatus INTEGER
  mltJmJobReceivedTime DateAndTime
  mltJmJobCompleteTime DateAndTime
  mltJmJobPriority INTEGER
  mltJmJobDivNumber INTEGER
  mltJmJobOwner DisplayString
  mltJmJobType INTEGER
  mltJmJobName DisplayString
  mltJmJobDocPageNumbers Integer32
  mltJmJobDocCopyNumbers Integer32
  mltJmJobPageSize INTEGER
  mltJmJobDestination DisplayString
  mltJmJobDataSize Integer32
  mltJmJobColorMode INTEGER
  mltJmJobFormat INTEGER
  mltJmJobXResolution INTEGER
  mltJmJobYResolution INTEGER
  mltJmJobDuplex INTEGER
  mltJmJobOutputPages Integer32
  mltJmJobOutputSheets Integer32
  mltJmJobMediaType INTEGER

MltJmReportEntry  
SEQUENCE    
  mltJmReportIndex INTEGER
  mltJmReportAddress DisplayString
  mltJmKeepAliveCount INTEGER
  mltJmReportInterval INTEGER
  mltJmReporIntervalSelection INTEGER
  mltJmReportRequest INTEGER

Defined Values

minolta 1.3.6.1.4.1.2590
OBJECT IDENTIFIER    

mltMgmt 1.3.6.1.4.1.2590.1
OBJECT IDENTIFIER    

mltDirectory 1.3.6.1.4.1.2590.2
OBJECT IDENTIFIER    

mltMib 1.3.6.1.4.1.2590.1.1
OBJECT IDENTIFIER    

mltSystem 1.3.6.1.4.1.2590.1.1.1
OBJECT IDENTIFIER    

mltInterface 1.3.6.1.4.1.2590.1.1.2
OBJECT IDENTIFIER    

mltDevice 1.3.6.1.4.1.2590.1.1.3
OBJECT IDENTIFIER    

mltJob 1.3.6.1.4.1.2590.1.1.4
OBJECT IDENTIFIER    

mltPrinter 1.3.6.1.4.1.2590.1.1.1.1
OBJECT IDENTIFIER    

mltSysMib 1.3.6.1.4.1.2590.1.1.1.5
OBJECT IDENTIFIER    

mltNetwork 1.3.6.1.4.1.2590.1.1.2.1
OBJECT IDENTIFIER    

mltNetworkMib 1.3.6.1.4.1.2590.1.1.2.1.5
OBJECT IDENTIFIER    

mltJobManagement 1.3.6.1.4.1.2590.1.1.4.1
OBJECT IDENTIFIER    

mltPrinterMib 1.3.6.1.4.1.2590.1.1.1.1.6
OBJECT IDENTIFIER    

mltPrtMibInfo 1.3.6.1.4.1.2590.1.1.1.1.6.1
OBJECT IDENTIFIER    

mltPrtCommand 1.3.6.1.4.1.2590.1.1.1.1.6.4
OBJECT IDENTIFIER    

mltPrtConfig 1.3.6.1.4.1.2590.1.1.1.1.6.5
OBJECT IDENTIFIER    

mltPrtFont 1.3.6.1.4.1.2590.1.1.1.1.6.6
OBJECT IDENTIFIER    

mltPrtPaper 1.3.6.1.4.1.2590.1.1.1.1.6.7
OBJECT IDENTIFIER    

mltPrtRemotePanel 1.3.6.1.4.1.2590.1.1.1.1.6.10
OBJECT IDENTIFIER    

mltPrtMibVersion 1.3.6.1.4.1.2590.1.1.1.1.6.1.1
The standardization version of MIB implemented in a printer. This indicates the version of the Private Printer MIB that is implemented. There are some mib objects that indicate the Mib Version. (mltSysMibVersion, mltPrtMibVersion, mltScnMibVersion, mltNetMibVersion, mltJmMibVersion) But, the each mib version should be same version. Especially, the each major versions must be same. A string specifying Printer MIB Standard specification version. General form is ##.XX. ## is indicating major revision, and XX is minor revision. Decimal point is ASCII-coded period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..7)  

mltPrtCommandTable 1.3.6.1.4.1.2590.1.1.1.1.6.4.1
The table for showing the command information of printer relation. This table must be implemented even if no function in this table are supported by a model.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtCommandEntry

mltPrtCommandEntry 1.3.6.1.4.1.2590.1.1.1.1.6.4.1.1
An entry exists in this table for each device entry in the hostmib device table whose type is 'printer'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltPrtCommandEntry  

mltPrtCommandOnline 1.3.6.1.4.1.2590.1.1.1.1.6.4.1.1.1
Indicate printer online or offline. If printer has no online button, this value should be notSupported (0) as read-only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), onLine(1), offLine(2)  

mltPrtCommandJobCancel 1.3.6.1.4.1.2590.1.1.1.1.6.4.1.1.2
Command of cancel job. If printer has not job cancel function, this value should be notSupported (0) as read-only. In normal condition, this value should be notCancel (1). If canceling job, set this object jobCancel (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), notCancel(1), jobCancel(2)  

mltPrtCommandJobProceed 1.3.6.1.4.1.2590.1.1.1.1.6.4.1.1.3
Command of proceeds. If printer has not proceed function, this value should be notSupported (0) as read-only. In normal condition, this value should be notProceed (1). If proceeding job, set this object proceed (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), notProceed(1), jobProceed(2)  

mltPrtPrintPageTable 1.3.6.1.4.1.2590.1.1.1.1.6.4.2
A table of printable configuration print. If a printer does not support print the test pages from network access, this table needs not to be implemented.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtPrintPageEntry

mltPrtPrintPageEntry 1.3.6.1.4.1.2590.1.1.1.1.6.4.2.1
Information about printer's configuration prints. Entries may exist in the table for each device index whose device type is 'printer'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltPrtPrintPageEntry  

mltPrtPrintPageIndex 1.3.6.1.4.1.2590.1.1.1.1.6.4.2.1.1
Index for uniquely distinguishing the page held within a printer. Although the value of index depends on an implementation,
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

mltPrtPrintPageName 1.3.6.1.4.1.2590.1.1.1.1.6.4.2.1.2
The name of the page, which can be printed. The value that should be implemented depends on an implementation of a model and it should be common with a manual etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltPrtPrintCommand 1.3.6.1.4.1.2590.1.1.1.1.6.4.2.1.3
Command of print page. In normal condition , this value should be supported (1). If print page, set this object print (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER supported(1), print(2)  

mltPrtSysConfigTable 1.3.6.1.4.1.2590.1.1.1.1.6.5.1
A table of configurations for printer. This table must be implemented even if no functions in this table are supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtSysConfigEntry

mltPrtSysConfigEntry 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1
An entry exists in this table for each device entry in the hostmib device table whose type is 'printer'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltPrtSysConfigEntry  

mltPrtJobLanguage 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1.1
Configuration printer job language. Only in the case that a printer has a function of setting(changing) this default printer language, this object is implemented as RW. In the other case, this object should be implemented as RO. In case of PCL/PS printer, default value is Auto(0). If necessary, PCL(1)/PS(2) is changeable. In case of printer has only one interpreter (PCL or PS), this object should be pcl(1) or ps (2) as RO. In case of GDI printer, this value is GDI(3) (RO).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(0), pcl(1), ps(2), gdi(3), linePrinter(4), other(7)  

mltPrtPowerSave 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1.2
Timer value setting before the power save mode is asserted. Unit is minutes. If '0' is selected, the controller doesn't enter Power Save mode. If this value is -1, printer doesn't support power save mode. If out of spec value is set, Error is returned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltPrtAutoContinue 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1.3
The setting whether printing will automatically recover or not when an Error or Caution occurred. If a device support only the value of 1(off) and 2(ac0Sec), this implementation is allowed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), off(1), ac0Sec(2), ac10Sec(3), ac20Sec(4), ac30Sec(5), ac60Sec(6), ac90Sec(7), ac120Sec(8)  

mltPrtPaperTimeOut 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1.4
Setting which decides whether automatic recover should be proceed or not when an error related to paper occurred.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), off(1), proceedJob(2), cancelJob(3)  

mltPrtPsErrorPrint 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1.5
The setting whether the printer prints PostScript Error Page when PostScript Error occurred during job processing. About PS error, since it is the function of a printer controller, all the devices with PS should be implemented If a device has no PostScript interpreter, this value should be always notSupported(0) as RO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), off(1), on(2)  

mltPrtPrintConfigTable 1.3.6.1.4.1.2590.1.1.1.1.6.5.2
A table of configurations for printer. This table must be implemented even if no functions in this table are supported.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtPrintConfigEntry

mltPrtPrintConfigEntry 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1
An entry exists in this table for each device entry in the hostmib device table whose type is 'printer'
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltPrtPrintConfigEntry  

mltPrtCopies 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1.1
The number of printing copies. If set value is over limit, printer should return error. About device which has no PCL interpreter, This value should be -1, because of no default copies setting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltPrtPaperSize 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1.2
Paper size of printing. The value of the mltPaperSizeIndex corresponding to the current paper size. About device which has no PCL interpreter, This value should be -1, because of no default paper size setting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltPrtPaperSource 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1.3
Feeders for printing. The value of prtInputIndex corresponding to the default input sub-unit: that is, this object selects the default source of input media. If value is 0, this means 'Auto'. About device which has no PCL interpreter, This value should be -1, because of no default paper source setting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltPrtFineArt 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1.4
Smooting setting. If printer has no smoothing function, this value should be notSupported(0) and RO. If printer supports only On/Off , this value should be on(1) or offSwitch(2). If printer supports 4 steps, this value should be dark(3), medium(4), light(5) and offStep(6).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), on(1), offSwitch(2), dark(3), medium(4), light(5), offStep(6)  

mltPrtTonerSave 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1.5
Toner saving setting. If printer is not supporting toner save function, this value should be notSupported(0) and RO. If printer is supporting toner save function, this value should be on(1) or off(2) and RW.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), on(1), off(2)  

mltPrtPclFontTable 1.3.6.1.4.1.2590.1.1.1.1.6.6.1
This table shows PCL font information of printer has. Since it is a function peculiar to PCL, it is not necessary to implement this table in the device in which PCL is not installed or PCL font management function is not installed.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtPclFontEntry

mltPrtPclFontEntry 1.3.6.1.4.1.2590.1.1.1.1.6.6.1.1
Information about printer's PCL fonts. Entries may exist in the table for each device index whose device type is 'printer'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltPrtPclFontEntry  

mltPrtPclFontIndex 1.3.6.1.4.1.2590.1.1.1.1.6.6.1.1.1
A unique value used to identify this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

mltPrtPclFontName 1.3.6.1.4.1.2590.1.1.1.1.6.6.1.1.2
The name of PCL Font.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltPrtPclFontNumber 1.3.6.1.4.1.2590.1.1.1.1.6.6.1.1.3
The number of PCL Font. The number for managing the font, which a printer holds inside.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

mltPrtPclFontSource 1.3.6.1.4.1.2590.1.1.1.1.6.6.1.1.4
The information of a place that PCL font exists.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), internalRom(1), internalHd(2), downLoadRam(3), downLoadHd(4), downLoadFlashRom(5)  

mltPrtPsFontTable 1.3.6.1.4.1.2590.1.1.1.1.6.6.2
This table shows PostScript font information of printer has. Since it is a function peculiar to PS, it is not necessary to implement this table in the device in which PS is not installed.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtPsFontEntry

mltPrtPsFontEntry 1.3.6.1.4.1.2590.1.1.1.1.6.6.2.1
Information about printer's PS fonts. Entries may exist in the table for each device index whose device type is 'printer'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltPrtPsFontEntry  

mltPrtPsFontIndex 1.3.6.1.4.1.2590.1.1.1.1.6.6.2.1.1
A unique value used to identify this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

mltPrtPsFontName 1.3.6.1.4.1.2590.1.1.1.1.6.6.2.1.2
The name of PS Font.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltPrtPsFontNumber 1.3.6.1.4.1.2590.1.1.1.1.6.6.2.1.3
The number of PS Font. This number is used in order to administrate printer's fonts. If a printer does not manage this number, this value should be implemented same as mltPrtPsFontIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

mltPrtPsFontSource 1.3.6.1.4.1.2590.1.1.1.1.6.6.2.1.4
The information of a place that PS font exists
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), internalRom(1), internalHd(2), downLoadRam(3), downLoadHd(4), downLoadFlashRom(5)  

mltPrtSymbolSetTable 1.3.6.1.4.1.2590.1.1.1.1.6.6.3
This table shows symbol sets a printer has. If no function in this table is supported by a device, this table needs not to be implemented.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtSymbolSetEntry

mltPrtSymbolSetEntry 1.3.6.1.4.1.2590.1.1.1.1.6.6.3.1
Information about printer's symbol sets. Entries may exist in the table for each device index whose device type is 'printer'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltPrtSymbolSetEntry  

mltPrtSymbolSetIndex 1.3.6.1.4.1.2590.1.1.1.1.6.6.3.1.1
A unique value used to identify this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

mltPrtSymbolSetName 1.3.6.1.4.1.2590.1.1.1.1.6.6.3.1.2
The name of SymbolSet (CodedCharSet).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltPrtCharSetID 1.3.6.1.4.1.2590.1.1.1.1.6.6.3.1.3
The ID of Code CharSet. Refer to the following URL that IANA administrates regarding character code sets: http://www.iana.org/assignments/character-sets
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

mltPrtPaperSizeTable 1.3.6.1.4.1.2590.1.1.1.1.6.7.1
A table of the printer selectable paper sizes. Even if a printer can not recognize the supportable paper, one object ('unknown' or 'other') must be loaded at least.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtPaperSizeEntry

mltPrtPaperSizeEntry 1.3.6.1.4.1.2590.1.1.1.1.6.7.1.1
An entry exists in this table for each device entry in the hostmib device table whose type is 'printer'
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltPrtPaperSizeEntry  

mltPaperSizeIndex 1.3.6.1.4.1.2590.1.1.1.1.6.7.1.1.1
A unique value used to identify this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

mltPaperSizeName 1.3.6.1.4.1.2590.1.1.1.1.6.7.1.1.2
The name of paper size. e.g., letter, legal, A4, B5 etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltPaperFeedDir 1.3.6.1.4.1.2590.1.1.1.1.6.7.1.1.3
This value shows paper feeding orientation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(0), sef(1), lef(2)  

mltPrtRemotePanelButtonTable 1.3.6.1.4.1.2590.1.1.1.1.6.10.1
A table of printer's remote operational panel button.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtRemotePanelButtonEntry

mltPrtRemotePanelButtonEntry 1.3.6.1.4.1.2590.1.1.1.1.6.10.1.1
An entry exists in this table for each device entry in the hostmib device table whose type is `printer'
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltPrtRemotePanelButtonEntry  

mltPrtPanelButtonIndex 1.3.6.1.4.1.2590.1.1.1.1.6.10.1.1.1
A unique value used by the operational panel button to identify table
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

mltPrtPanelButtonName 1.3.6.1.4.1.2590.1.1.1.1.6.10.1.1.2
The name of panel button.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltPrtPanelButtonPush 1.3.6.1.4.1.2590.1.1.1.1.6.10.1.1.3
This value indicates panel button status, and make pushing button. noAction (0) -- indicate steady. push (1) -- To set 1 means push panel button. longPush (2) -- To set 2 means push button long time. shiftPush (3) -- To set 3 means push panel bottom and shift button same time.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER noAction(0), push(1), longPush(2), shiftPush(3)  

mltPrtPanelButtonDescr 1.3.6.1.4.1.2590.1.1.1.1.6.10.1.1.4
An explanation of panel button function etc.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

mltSysMibVersion 1.3.6.1.4.1.2590.1.1.1.5.1
The version information of Standard MIB specification. This indicates the version of the Private System MIB which is implemented. General form is AA.BC. AA is indicating major revision, and B and C is minor revision. Decimal point is ASCII-coded period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..7)  

mltSysGeneralInfo 1.3.6.1.4.1.2590.1.1.1.5.2
OBJECT IDENTIFIER    

mltSysContact 1.3.6.1.4.1.2590.1.1.1.5.3
OBJECT IDENTIFIER    

mltSysVersion 1.3.6.1.4.1.2590.1.1.1.5.5
OBJECT IDENTIFIER    

mltSysComponent 1.3.6.1.4.1.2590.1.1.1.5.6
OBJECT IDENTIFIER    

mltSysCounter 1.3.6.1.4.1.2590.1.1.1.5.7
OBJECT IDENTIFIER    

mltSysPriorityDevice 1.3.6.1.4.1.2590.1.1.1.5.2.2
This object shows the function which operates with highest priority in a system. When it can set up by user choice etc., it should be RW. If setup change is impossible from MIB, the implementation of RO is acceptable. There is no function with highest priority or no preference order of function, implement RO as 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltSysCurrentDateTime 1.3.6.1.4.1.2590.1.1.1.5.2.4
Time, which is set in the system and specifies by DateAndTime If not having a clock function, implement 0x00 in all Bytes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DateAndTime  

mltSysContactSiteName 1.3.6.1.4.1.2590.1.1.1.5.3.1
The name of a support contact for system. If device cannot support this object, device should be implement '-' as read-only
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..64)  

mltSysContactInfo 1.3.6.1.4.1.2590.1.1.1.5.3.2
Explanation of a support contact for system. Default value shall be a blank, and a service person or a user shall input it. If device cannot support this object, device should be implement '-' as read-only
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

mltSysProductHelpURL 1.3.6.1.4.1.2590.1.1.1.5.3.3
URL of the support contact for system. If device cannot support this object, device should be implement '-' as read-only
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

mltSysCorpURL 1.3.6.1.4.1.2590.1.1.1.5.3.4
URL of the company which provides a system. If device cannot support this object, device should be implement '-' as read-only
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

mltSysSuppliesInfo 1.3.6.1.4.1.2590.1.1.1.5.3.5
A telephone number or E-mail addresses for the supplies and accessories, etc. In the support contact in which a system has. Default shall be a blank, and a service person or a user shall input it. If device cannot support this object, device should be implement '-' as read-only
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

mltSysVersionTable 1.3.6.1.4.1.2590.1.1.1.5.5.1
The table for showing ROM and F/W version in which a system has.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysVersionEntry

mltSysVersionEntry 1.3.6.1.4.1.2590.1.1.1.5.5.1.1
The version information of FW or ROM.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltSysVersionEntry  

mltSysVersionIndex 1.3.6.1.4.1.2590.1.1.1.5.5.1.1.1
Index for uniquely showing the version information in which a system has. The number and the order of index depends on an implementation of a model. Implement the maximum number of index of ROM and F/W which is possible to detect/display, regardless of the availability of installation of Option etc. The number of indexes to hold shall be always fixed regardless of the option installation state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysVerName 1.3.6.1.4.1.2590.1.1.1.5.5.1.1.2
The name of the function which shows a version. For example, 'MSC/Panel ROM Version', 'Printer ROM Version', etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltSysVersionCode 1.3.6.1.4.1.2590.1.1.1.5.5.1.1.3
The version of ROM and F/W. It shall be written by 15 or less characters. '[Product Code(4)]-[Block Code(2)][Stage Code(1)] [Specification Code(1)]-[Change Management Code(2)] -[Shipment Destination Code(2)]' supports. For corresponding to the other written methods, it was made into the maximum 31 characters, on the definition. When the value cannot acquire although index is set by Option etc., display '-' (hyphen).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltSysVerDescr 1.3.6.1.4.1.2590.1.1.1.5.5.1.1.4
Explanation of a version. As for the contents to indicate, depends on an implementation of a model. However, since not supporting this object is not acceptable, implement Null (Zero-Length) at least.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltSysCompConfigID 1.3.6.1.4.1.2590.1.1.1.5.6.1
Shows the ID by the combination of the structure of Device. A project should prepare ID which is worth for the number of combination, such as Option. If system has no option or cannot detect option installed, this value should be always 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysInputTrayTable 1.3.6.1.4.1.2590.1.1.1.5.6.2
The table for showing the information of Input tray that is installed in a system. As a principle, the un-acquirable information shall be displayed if there is only prtInputTable, and this table is premised on that PrinterMIB is being implemented. It shall display about InputTray which is installed like prtInputTable. If a system does not have a printer engine (has no input tray and no PrinterMIB), this table does not need to implement.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysInputTrayEntry

mltSysInputTrayEntry 1.3.6.1.4.1.2590.1.1.1.5.6.2.1
The information of paper input tray.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltSysInputTrayEntry  

mltSysInputTrayIndex 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.1
Index for showing InputTray in a system. Index depends on the state of the implementation of a model, and shall be taken the amount which is worth for the number of InputTray in the order from 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysInputTrayRefIndex 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.2
The value of prtInputIndex of a tray which mltSysInputTrayIndex shows.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysInputTrayName 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.3
The name of InputTray. Default value depends on a model. In principle, use the name unified by DriverUI. Set of the character string up to 15 characters shall be possible. implementation of RO is also accepted when there are capacity restrictions of NVRAM. Since this item is the value used when a user does a remote management, it is not necessary to link it with a setup of a printer engine. SNMP agent holds value, and should just provide the convenience to the user who remote accesses.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

mltSysInputTrayCapacitySence 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.4
This item shows the detection method of paper residual quantity, and is used for distinction of the value displayed in prtInputCurrentLevel. The details of a residual quantity display are indicated to prtInputCurrentLevel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noSensor(0), emptyOnly(1), nearEmpty(2), linearSense(3)  

mltSysInputTraySpecialPaper 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.5
Shows the media type of InputTray. If this value is RW and when a setup is changed by MIB, it shall be reflected in a setup of a printer engine. In a unavoidable case, the access way may be RO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(0), unknown(1), plainPaper(10), plainPaper-NotFor2Sided(11), plainPaper-Recycled(12), plainPaper-Exclusive(14), plainPaper-Color(16), thick(20), thick1(22), thick1-2side(23), thick2(24), thick2-2side(25), thick3(26), thick3-2side(27), ohp(30), thin(36), envelope(40), envelope-2side(41), label(42), postCard(44), letterHead(46), tab(48)  

mltSysInputTrayPaperAttribute 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.6
Shows the paper attribute of InputTray. If this value is RW and when a setup is changed by MIB, it shall be reflected in a setup of a printer engine. In a unavoidable case, the access way may be RO.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), s0-normalPaper(1), s1-recyclePaper(2), s2-specialPaper(3), s3-reusePaper(4)  

mltSysOutputTrayTable 1.3.6.1.4.1.2590.1.1.1.5.6.3
The table for showing the information of OutputTray relation in a system. Index shall be mltSysOutputTrayIndex. This table is for displaying the tray information of OutputOption (Finisher), and shall not include the function information of Finisher. If a system does not have a printer engine (has no output tray and no PrinterMIB), this table may not be implemented.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysOutputTrayEntry

mltSysOutputTrayEntry 1.3.6.1.4.1.2590.1.1.1.5.6.3.1
The information of paper output tray.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltSysOutputTrayEntry  

mltSysOutputTrayIndex 1.3.6.1.4.1.2590.1.1.1.5.6.3.1.1
Index for showing OutputTray in a system. Index depends on the implementation of a model, and shall be taken the amount which is worth for the number of Output in the order from 1. In principle, when the top tray is set as 1, index shall be increased in progress of going to the lower part. As for the middle processing tray that does not become papers' final output destination, is not treated as OutputTray.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysOutputTrayRefIndex 1.3.6.1.4.1.2590.1.1.1.5.6.3.1.2
Value of prtOutputIndex of the tray which mltSysOutputTrayIndex shows.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysOutputTrayDefaultName 1.3.6.1.4.1.2590.1.1.1.5.6.3.1.3
The name of OutputTray. Unify with the notation of a manual or a driver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltSysOutputTrayNickName 1.3.6.1.4.1.2590.1.1.1.5.6.3.1.4
The name of OutputTray in which a user can set up. In MailBin, use it in order to indicate a user's name, etc. which each Tray set up. The recommendation default is the same as mltSysOutputTrayDefaultName. Set of the character string up to 15 characters shall be possible, and neither retrenchment of the number of characters which can be written in, nor implementation of RO shall be accepted. However, the implementation of RO is accepted only to the thing without MailBin as OutputOption. Moreover, being reflected in the display screen of a printer driver is desirable. Since this item is the value used when a user does a remote management, it is not necessary to link it with a setup of a printer engine. SNMP agent holds value, and should just provide the convenience to the user who remote accesses. If device cannot support this function, this object should be '-' as ReadOnly.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

mltSysOutputTrayType 1.3.6.1.4.1.2590.1.1.1.5.6.3.1.5
Shows the type of tray in OutputTray. This is an item for judging whether it is MailBin, and it is used in order to judge whether the writing of NickName should be possible.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(0), standardBin(1), sortBin(3), mailBox(4), fixedMailBin(5)  

mltSysCounterConfig 1.3.6.1.4.1.2590.1.1.1.5.7.1
OBJECT IDENTIFIER    

mltSysSystemCounter 1.3.6.1.4.1.2590.1.1.1.5.7.2
OBJECT IDENTIFIER    

mltSysSupportedCounterType 1.3.6.1.4.1.2590.1.1.1.5.7.1.1
Shows the type of a counter installed in a system. The counter which a system has can specify by referring to this. Displays the counter to support with Bitmap and shows the supporting counter by the total. Bit Value CounterType --- ----- --------------- 0 1 GeneralCounter 1 2 PrintFunctionCounter 2 4 SendFunctionCounter 3 8 PapersSizeCounter 4 16 DivCounter 5 32 TonerLifeCounter It becomes 63 when implementing all the counters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysDuplexCountMode 1.3.6.1.4.1.2590.1.1.1.5.7.1.2
Sets up whether Duplex printing is counted two times to TotalCounter at the time. This setup is reflected to all TotalCounters. This object may be implemented with RO access. If a system doesn't have this setting (e.g. printer), the value of the static count mode (1 or 2) must be implemented. Basically this value must not be '0'. This is also applied to mtSysLargeSizeCountMode and mltSysLargeSizeMode same.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(0), singleCount(1), doubleCount(2)  

mltSysLargeSizeCountMode 1.3.6.1.4.1.2590.1.1.1.5.7.1.3
Sets up whether LargeSize is counted two times to TotalCounter at the time. This setup is reflected to all TotalCounters. This object may be implemented with RO access. This setting is the item of a service choice. A setup of a service choice is reflected to this object. Also enable operation from PageScope. Management of the access rights supports by PageScope side.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(0), singleCount(1), doubleCount(2)  

mltSysLargeSizeType 1.3.6.1.4.1.2590.1.1.1.5.7.1.4
Sets up the type of paper counted as LargeSize. noLargeSize(0): indicates that the count of LargeSize is not performed or not detect large size type. typeA(1): For US is 11x17, For EU is A3, For Japan is A3. typeB(2): For US is 11x17, For EU is A3/B4, For Japan is A3/B4. typeC(3): For US is 11x17/11x14/8.5x14, For EU is A3/B4, For Japan A3/B4. This object may be implemented with RO access. The choice item of EP-NET. Also enable operation from PageScope.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noLargeSize(0), typeA(1), typeB(2), typeC(3)  

mltSysColorCountSupportType 1.3.6.1.4.1.2590.1.1.1.5.7.1.5
It is shown what kind of counter by the color is supported. The color counter which a device supports can be specified by referring to this. Displays the type of counter to support with Bitmap and shows the supporting counter by the total. The type counter that is shown in here shall be held by the color-related counter. Bit Value CounterType --- ----- ----------------- 0 1 reserved 1 2 bw --The monochrome counter --in a color machine 2 4 fourColor (4c) --Full color -- (All of C, M, Y, and K are used) 3 8 threeColor (3c) --Monochrome color --(monochrome is taken out using -- three colors of C, M, and Y) 4 16 cmy --CMY: (using any 1 color of C/M/Y) 5 32 rgb --RGB: (using three colors of CMY) 6 64 monoColor --The total of 3C, CMY, and RGB 7 128 paperPath --PaperPath counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysGeneralCounter 1.3.6.1.4.1.2590.1.1.1.5.7.2.1
OBJECT IDENTIFIER    

mltSysTotalCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.1
The total print count of a system. Displays the total of Copy, Print, and Receiving Job. About the count method of Duplex and LargeSize, it depends on a setup. A count shall be an output count. About a color machine, it shall be the total of all color classifications.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysLargeSizeCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.2
The total print count of LargeSize paper. About the type of LargeSize, it depends on a setup of mltSysLargeSizeType. When the setup of mltSysLargeSizeType is noCount(0), this counter always shall be -1. In addition, also in the system without A4 machine, etc., this counter should be -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysDuplexCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.3
The total print count of Duplex (back). In the system without Duplex mechanism, it should be -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysLargeDuplexCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.4
The total print count of LargeSize, and also Duplex (back). About the type of LargeSize, it depends on a setup of mltSysLargeSizeType. When the setup of mltSysLargeSizeType is noCount(0), this counter always shall be -1. In addition, in the system of A4 machine or in the system without Duplex, this counter always should be -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysSendTotalCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.5
Total count scaned as a transmitting function in the system. It shall be the total of mltSysSendScanCount. In the device without Scan function, it always shall be -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysTotalJamCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.6
The number of times of Jam occurred in the system. It shall be the total of all Jam counters. (including ADF jams).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysTotalTroubleCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.7
The number of times of Trouble (FatalError) occurred in the system. It shall be the total of all Trouble counters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysPrintFunctionCounterTable 1.3.6.1.4.1.2590.1.1.1.5.7.2.2
The table for showing the counter by the color and function. In the monochrome machine of a single function, it is not necessary to implement.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysPrintFunctionCounterEntry

mltSysPrintFunctionCounterEntry 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1
The counters of color and print functions.
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltSysPrintFunctionCounterEntry  

mltSysPrintFunctionColorIndex 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.1
Index for showing the color in the counter by color/function. By the color, index shall be attached in the order of the following. No. Function -------------------- 1 BW 2 4C 3 3C 4 CMY 5 RGB 6 MonoColor
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysPrintFunctionIndex 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.2
Index for showing the function in the counter by color/function. By the function, index shall be attached in the order of the following. No. Function -------------------- 1 copy 2 printer 3 received Job 4 fax received Job 5 reportPrint Although classifying into printer/receive Job/fax receive job as a printing function is recommended, the implementation of multiple counting as a printer function is also accepted.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysPrintFunctionColorType 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.3
Shows the color mode in the counter by color/function.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER bw(1), fourColor(2), threeColor(3), cmy(4), rgb(5), monoColor(6), paperPath(7)  

mltSysPrintFunctionType 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.4
Shows the function in the counter by color/function. Although classifying into printer/receive Job/fax receive job as a printing function is recommended, the implementation of multiple counting as a printer function is also accepted.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER copyFunction(1), printFunction(2), receiveFunction(3), faxReceiveFunction(4), reportPrint(5)  

mltSysPrintFunctionTotalCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.5
The total print count in a specified function. About the count method, complies with GeneralCounter
Status: optional Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysPrintFunctionDuplexCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.6
The print count of Duplex (back) in a specified function. The print count of the LargeSize paper in a specified function. About the count method, complies with GeneralCounter.
Status: optional Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysPrintFunctionLargeSizeCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.7
The print count of the LargeSize paper in a specified function. About the count method, complies with GeneralCounter.
Status: optional Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysPrintFunctionLargeDuplexCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.8
The print count of LargeSize and Duplex (back) in a specified function. About the count method, complies with GeneralCounter.
Status: optional Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysSizeCounterTable 1.3.6.1.4.1.2590.1.1.1.5.7.2.4
The table of the counter by the paper sizes (types). The model which supports plural paper sizes has to implement. Regardless of shipment destination, having a counter to all the paper sizes that can be printed is recommended. By implementation, implementing different size counter by shipment destination is also accepted. It shall also have index by the functions so that it can correspond to the counter by sizes by the functions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysSizeCounterEntry

mltSysSizeCounterEntry 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1
The information of paper size counters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltSysSizeCounterEntry  

mltSysSizeFunctionIndex 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1.1
Index for showing the function which becomes the count object in the counter by paper sizes. Although Index shall be attached in the order of the following by the function, having Index by fixation shall not require. No. Function -------------------- 1 Total
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysSizeTypeIndex 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1.2
Index for showing the paper which becomes the count object in the counter by paper sizes. Only the type of corresponding paper shall be taken in the order from 1. Using fixed index for every paper does not require.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysSizeFunction 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1.3
Shows the function which becomes the count object in the counter by paper size.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER total(0)  

mltSysSizeType 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1.4
Shows the paper which becomes the count object in the counter by paper sizes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER otherPaperSize(0), unknownPaperSize(1), a0(11), a1(12), a2(13), a3(14), a4(15), a5(16), a6(17), b0(21), b1(22), b2(23), b3(24), b4(25), b5(26), b6(27), us12x14(30), ledger(31), us11x15(32), us11x14(33), comp(34), us10x14(35), us9-1by4x14(36), legal(37), us8-1by4x11-3by4(38), letter(39), govermentLetter(40), quarto(41), executive(42), statement(43), fls(50), fls0(51), fls1(52), fls2(53), fls3(54), hagaki(61), oufuku-Hagaki(62), envelopeB5(63), envelopeCom10(64), envelopeC5(65), envelopeDL(66), envelopeMonarch(67), envelopeC6(68), youkei-0Gou(70), youkei-4Gou(71), youkei-6Gou(72), choukei-3Gou(83), choukei-4Gou(84), kakugata-3Gou(93), special0(100), special1(101), special2(102), special3(103), special4(104), special5(106), a3W(114), a4W(115), a5W(116), a6W(117), otherPaperAttribute(199), unknownPaperAttribute(200), plain(201), exclusive(202), notFor2Sided(203), specialPaper(204), cover(205), inserter(206), reuse(207), otherMediaType(208), unknownMediaType(209), plainPaper(210), plainPaper-2side(211), plainPaper-Recycled(212), plainPaper-Exclusive(214), plainPaper-Color(216), thick1(222), thick1-2side(223), thick2(224), thick2-2side(225), thick3(226), thick3-2side(227), ohp(230), thin(236), envelope(240), envelope-2side(241), label(242), postCard(244), letterHead(246), tab(248)  

mltSysSizeCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1.5
The number of print of the specified function and specified size, media type, or attribute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

mltSysTonerLifeCounterTable 1.3.6.1.4.1.2590.1.1.1.5.7.2.5
The table of toner life counter.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysTonerLifeCounterEntry

mltSysTonerLifeCounterEntry 1.3.6.1.4.1.2590.1.1.1.5.7.2.5.1
The information of toner life counters.
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltSysTonerLifeCounterEntry  

mltSysTonerTypeIndex 1.3.6.1.4.1.2590.1.1.1.5.7.2.5.1.1
Index for Toner used as the count object in TonerLife counter being shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltSysTonerType 1.3.6.1.4.1.2590.1.1.1.5.7.2.5.1.2
Toner used as the count object in TonerLife counter is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(0), cyan(1), magenta(2), yellow(3), black(4)  

mltTonerTypeCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.5.1.3
TonerLife count. This is used for calculation of Coverage, by the amount of Toner consumption, etc. by counting Dot number used for every Toner. 1unit is 2M Dots.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter32  

mltNetMibVersion 1.3.6.1.4.1.2590.1.1.2.1.5.1
The standardization version of MIB implemented in Network. This indicates the version of the Private Network MIB. General form is AA.BC. AA is indicating major revision, and B and C is minor revision. Decimal point is ASCII-coded period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..7)  

mltNetGeneral 1.3.6.1.4.1.2590.1.1.2.1.5.2
OBJECT IDENTIFIER    

mltNetProtocol 1.3.6.1.4.1.2590.1.1.2.1.5.3
OBJECT IDENTIFIER    

mltNetCommand 1.3.6.1.4.1.2590.1.1.2.1.5.5
OBJECT IDENTIFIER    

mltNetSnmp 1.3.6.1.4.1.2590.1.1.2.1.5.6
OBJECT IDENTIFIER    

mltNetTcpip 1.3.6.1.4.1.2590.1.1.2.1.5.7
OBJECT IDENTIFIER    

mltNetNetWare 1.3.6.1.4.1.2590.1.1.2.1.5.8
OBJECT IDENTIFIER    

mltNetAppleTalk 1.3.6.1.4.1.2590.1.1.2.1.5.9
OBJECT IDENTIFIER    

mltNetSmb 1.3.6.1.4.1.2590.1.1.2.1.5.10
OBJECT IDENTIFIER    

mltNetGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.2.1
Table for showing the general information of Network relation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetGeneralEntry

mltNetGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1
General information of network interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetGeneralEntry  

mltNetGeneralIndex 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.1
Index for showing NetworkInterface installed to a device. Basically, it shall take the same value with ifIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetFirmVersion 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.2
Shows the FW version of NetworkInterface. Write it as ##.xx. ## shall be a major version and xx shall be a minor version. If there is no original FW of NetworkInterface, implement character strings of '-' (hyphen).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..7)  

mltNetHardwareAddress 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.3
MAC address of NetworkInterface. (Hardware address) In the device of our company, it was made into RW since MAC address needs to be written at the time of shipment. Implement as RO when the writing of MAC address is unnecessary. Moreover, in a management tool side, be sure to handle it as RO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  PhysAddress  

mltNetSerialNumber 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.4
The serial number of NetworkInterface. Implement '-' (hyphen) in the device without a serial number. In the device of our company, it was made into RW since serial number may need to be written at the time of shipment. Implement as RO when the writing of serial number is unnecessary. Moreover, in a management tool side, be sure to handle it as RO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

mltNetSupportedConnector 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.5
An integer bitmap value specifying network connector information. Each bit in the integer is defined as follows. bit Value Connector --- ----- --------- 0 1 Reserved 1 2 Ethernet AUI -- 10Base5 2 4 Ethernet BNC -- 10Base2 3 8 Ethernet RJ45 -- 10/100BaseT 4 16 Ethernet Fiber -- 10/100BaseF 5 32 Reserved 6 64 Reserved 7 128 TokenRing STP(DB-15) 8 256 TokenRing UTP(RJ-45) 9 512 TokenRing Fiber 10 1024 Reserved 11 2048 wirelessA -- 802.11a 12 4096 wirelessB -- 802.11b 13 8132 blueTooth 14 16364 ieee1394 -- IP over IEEE1394
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetCurrentConnector 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.6
Shows the connector that is working on NetworkInterface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notWorking(0), etherAUI(1), etherBNC(2), etherRJ(3), etherFiber(4), tokenSTP(7), tokenUTP(8), tokenFiber(9), wirelessA(11), wirelessB(12), blueTooth(13), ieee1394(14)  

mltNetSpeedConfig 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.7
Sets up the speed of NetworkInterface. Refer to ifSpeed for checking the present speed of operation. If this setting can not be set from Network access, a device should implement a current set value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(0), autoDetectEther(1), et10MbpsHalfDuplex(2), et10MbpsFullDuplex(3), et100MbpsHalfDuplex(4), et100MbpsFullDuplex(5), etGbpsHalfDuplex(6), etGbpsFullDuplex(7), autoDetectToken(10), tr4Mbps(11), tr16Mbps(12), tr32Mbps(13), autoDetectWireless(20), wireless1Mbps(21), wireless2Mbps(22), wireless5-5Mbps(23), wireless11Mbps(24)  

mltNetInterfaceType 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.8
Shows the type of NetworkInterface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(0), ieee1284(1), ieee1394(2), usb(3), dual1284(10), dpo(11), psio(12), onBoardDPO(100), noPhysicalNIC(101), onBoard(102), onBoardOneChip(103), onBoardPSIO(104), pciNonIntelligent(201), pciIntelligent(202)  

mltNetIfDescr 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.9
Explanation of NetworkInterface. Shows the type of port and the version information. The name to indicate is determined at Project side and implementation of NullString is not accepted. Even if a device have a no description about this, '-' need to be implemented.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltNetProtocolTable 1.3.6.1.4.1.2590.1.1.2.1.5.3.1
The table for showing the protocol information which NetworkInterface supports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetProtocolEntry

mltNetProtocolEntry 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1
The information of protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetProtocolEntry  

mltNetProtocolIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.1
Index for showing NetworkInterface that a system has. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetProtocolIndex 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.2
Index for uniquely showing the protocol which a system supports. Index shall be assigned in the following order is recommended. No. Protocol -------------------- 1 TCP/IP 2 NetWare(IPX/SPX) 3 AppleTalk 4 SMB
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetProtocolType 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.3
Shows the type of supporting protocol.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), tcp-ip(1), netWare(2), appleTalk(3), smb(4), other(7)  

mltNetProtocolDescr 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.4
Description that shows a protocol. Although the value to indicate shall depend on an implementation, the general protocol name, such as 'TCP/IP', 'NetWare', etc., shall be indicated in principle. Implementation of Null is not accepted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

mltNetProtocolVer 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.5
The version of the implemented protocol stack. Implement '-' (hyphen) when there is no version notation. Implementation of Null is not accepted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

mltNetProtocolOnOff 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.6
Sets up a states display of On and Off of the function of each protocol. If this setting can not be set from Network access, a device should implement a current set value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), enable(1), disable(2)  

mltNetCommandTable 1.3.6.1.4.1.2590.1.1.2.1.5.5.1
The table for showing the command information which NetworkInterface supports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetCommandEntry

mltNetCommandEntry 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1
The information of command for network interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetCommandEntry  

mltNetCommandIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.1
Index for uniquely showing the destination of command. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetCommandReset 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.2
The command that performs independent reset of NetworkInterface. When reset(2) is set, an agent side shall surely return Reply. Implementation that performs Reset immediately without returning Reply is not accepted. Return Reply of an error, when Reset command is invalid. After reset(2) is set, about the timing which is actually performing Reset depends on an implementation, and it shall not be defined in MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), reset(2)  

mltNetCommandDefault 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.3
The command for returning a setup about NetworkInterface to FactoryDefault. When resetToDefault(2) is set, an agent side shall surely return Reply. In principle, when resetToDefault(2) is set, about the timing in which the setup returns to default depends on an implementation and it does not define in MIB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), resetToDefault(2)  

mltNetCommandPrintNicConfig 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.4
The command for making it perform the output of ConfigPage which Network Interface has at the time of normal operation. Independent ConfigPage of two or more kinds of Network is not considered.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(10), supported(11), printing(12)  

mltNetCommandStartupConfig 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.5
The command that sets up the availability of the output of ConfigPage of NetworkInterface at the time of starting. Independent StartupPage of two or more kinds of Network is not considered.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(10), supported(11), printStartUp(12)  

mltNetCommandDownLoad 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.6
The command that sets up the mode that updates FW of NetworkInterface. Since this setup needs to operate with Admin authority, do not perform both display and writing at the management tool side.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(0), notDownLoad(1), downLoading(2)  

mltNetSnmpCommTable 1.3.6.1.4.1.2590.1.1.2.1.5.6.1
The table for showing the information of Community of SNMP which a system has. In addition, Community name shall be the common to the whole system on the premise, and shall not have independent Community for every NetworkInterface. In having Community independently by Intelligent NIC etc., it shall have NetworkMIB independently to each and is not managed by unified agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSnmpCommEntry

mltNetSnmpCommEntry 1.3.6.1.4.1.2590.1.1.2.1.5.6.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetSnmpCommEntry  

mltNetSnmpCommIndex 1.3.6.1.4.1.2590.1.1.2.1.5.6.1.1.1
Index for identifying each SNMP community. Although about Community number to support, Community name, and each access rights are dependent on an implementation, having the following three Communities is recommended. public (RO) private (RW) admin (RW) It shall be indispensable at least to have public (RW) or to have the two of public (RO) and private (RW).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSnmpCommName 1.3.6.1.4.1.2590.1.1.2.1.5.6.1.1.2
Community name of SNMP. Having the above-mentioned name as default is recommended. This item does not accept the implementation of RO. Community name has to be changeable. But if Community name can not be changeable, 'public' or 'private' is recommended to be implemented as Community name with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

mltNetSnmpCommAccessRight 1.3.6.1.4.1.2590.1.1.2.1.5.6.1.1.3
Shows the access rights of SNMP community. If this setting can not be set from Network access, a device should implement a current set value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(0), readOnly(1), writeOnly(2), readWrite(3)  

mltNetSnmpTrapTable 1.3.6.1.4.1.2590.1.1.2.1.5.6.2
The table for showing the information of destination of Trap of SNMP. When it does not have Trap function of SNMP, this Table does not need to implement.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSnmpTrapEntry

mltNetSnmpTrapEntry 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetSnmpTrapEntry  

mltNetSnmpTrapIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.1
The index for uniquely showing the NetworkInterface which becomes the sender of Trap. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSnmpTrapIndex 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.2
The index for uniquely showing the destination of Trap. In Default, it shall have at least one TrapAddress in a Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSnmpTrapCommunity 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.3
Community name at the time of transmitting Trap. In Default, it shall have public. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

mltNetSnmpTrapIpAddress 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.4
IP address of Trap destination. It shall be 255.255.255.255 (BroadCast) in Default. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mltNetSnmpTrapIpxAddress 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.5
IPX address of the destination of Trap. It shall be 'FFFFFFFF:FFFFFFFFFFFFFFFF' in Default. When it does not have Trap transmitting function in IPX, the character string of '-' (hyphen) shall be displayed. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetSnmpTrapOnOff 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.6
On/Off of transmission of Trap is controlled. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

mltNetTcpipGeneral 1.3.6.1.4.1.2590.1.1.2.1.5.7.1
OBJECT IDENTIFIER    

mltNetLpd 1.3.6.1.4.1.2590.1.1.2.1.5.7.2
OBJECT IDENTIFIER    

mltNetFtpd 1.3.6.1.4.1.2590.1.1.2.1.5.7.6
OBJECT IDENTIFIER    

mltNetHttpd 1.3.6.1.4.1.2590.1.1.2.1.5.7.8
OBJECT IDENTIFIER    

mltNetSmtpClient 1.3.6.1.4.1.2590.1.1.2.1.5.7.13
OBJECT IDENTIFIER    

mltNetIpp 1.3.6.1.4.1.2590.1.1.2.1.5.7.14
OBJECT IDENTIFIER    

mltNetSlp 1.3.6.1.4.1.2590.1.1.2.1.5.7.17
OBJECT IDENTIFIER    

mltNetTcpipGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1
Table with the basic information of TCP/IP relation which NetworkInterface has.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetTcpipGeneralEntry

mltNetTcpipGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetTcpipGeneralEntry  

mltNetTcpipIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.1
Index for uniquely showing NetworkInterface which IP address is set up. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetTcpipDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.2
The command that returns all setup about TCP/IP to FactoryDefault. When resetToDefault(2) is set, an agent side shall surely return Reply. In principle, when resetToDefault(2) is set, about the timing in which the setup returns to default depends on an implementation and it does not define in MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), resetToDefault(2)  

mltNetTcpipAddress 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.3
IP address of NetworkInterface. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mltNetTcpipSubnet 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.4
Subnet mask of NetworkInterface. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mltNetTcpipGateway 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.5
DefaultGateway of NetworkInterface. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mltNetTcpipUseBootProtocol 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.6
Specifies the IP address acquisition method of NetworkInterface. The value taken by default depends on the implementation of a model. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER neverUse(0), useWhenNoAddress(1), useEveryTime(2)  

mltNetTcpipBootProtocolEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.7
Bitmap for specifying BootProtocol used in order to determine the IP address of NetworkInterface. The value that should have by Default depends on the implementation of a model. An integer bitmap value specifying bootProtocols. Each bit in the integer is defined as follows. bit Value Type --- ----- --------- 0 1 Arp & Ping 1 2 RARP 2 4 BootP 3 8 DHCP 4 16 AutoIP If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetTcpipAddressServer 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.8
IP address of Server which offered IP address when IP address was acquired by bootProtocol. When it is manually inputted or Address in NVRAM is used, '0.0.0.0' shall be inputted for this value. This value shall be held even if turning a power supply off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

mltNetTcpipRawPortNumber 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.9
Port number for RAW socket printing. Default shall be '9100'. In addition, two or more RAW Port printings shall not be supported. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetTcpipSupportService 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.10
In NetworkInterface, shows the service supported on TCP/IP by Bitmap. An integer bitmap value specifying TCP/IP support service information. Each bit in the integer is defined as follows. bit Value Service --- ----- --------- 0 1 Reserved 1 2 Reserved 2 4 LPD 3 8 Reserved for LPR 4 16 telnet 5 32 Reserved for telnet client 6 64 ftp server 7 128 ftp client 8 256 http server 9 512 Reserved for http client 10 1024 Reserved for POP3 server 11 2048 POP3 client 12 4096 Reserved for SMTP server 13 8132 SMTP client 14 16364 ipp 15 32768 Reserved 16 65536 Reserved 17 131072 slp 18 262144 Reserved for IMAP server 19 524288 IMAP client 20 1048576 Reserved 21 2097152 Reserved for UPnP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetTcpipDnsSupport 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.11
Sets up the availability of use of DNS. The following value shall be used. When DNS is not being supported, always takes 0. When supporting, Default shall be noUse(2). If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(0), use(1), noUse(2)  

mltNetTcpipDnsHostName 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.12
The host name of NetworkInterface used by DNS. Default in the case of supporting DNS is Null (size =0). When DNS is not being supported, implement '-' (hyphen) and shall be RO. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltNetTcpipDnsDomainName 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.13
Domain name to which NetworkInterface used by DNS belongs. Default in the case of supporting DNS is Null (size =0). When DNS is not being supported, implement '-' (hyphen) and shall be RO. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltNetTcpipDnsTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.2
The table for showing DNS Server.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetTcpipDnsEntry

mltNetTcpipDnsEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetTcpipDnsEntry  

mltNetTcpipDnsIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.2.1.1
The index for uniquely showing NetworkInterface to which IP address is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetTcpipDnsServerIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.2.1.2
The index for uniquely showing each DNS Server. It shall have at least one or more Indexes as Default. The number of Indexes depends on an implementation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetTcpipDnsServerAddress 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.2.1.3
IP address of DNS Server. If this setting can not be set from Network access, a device should implement this value with RO access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mltNetLpdGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.1
The table for showing the general information of lpd.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetLpdGeneralEntry

mltNetLpdGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetLpdGeneralEntry  

mltNetLpdIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.1.1.1
The index for uniquely specifying NetworkInterface to which lpd is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetLpdEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.1.1.2
Sets up Enable/Disable of service of lpd.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetLpdPort 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.1.1.3
Specifies Port number which lpd uses. Default is 515.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetLpdQueueTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2
The table for showing the information of Queue of lpd.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetLpdQueueEntry

mltNetLpdQueueEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetLpdQueueEntry  

mltNetLpdQueueIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.1
The index for uniquely specifying NetworkInterface to which each Queue is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetLpdQueueIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.2
The index for uniquely showing Queue set up for every NetworkInterface. The number of Indexes depends on an implementation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetLpdQueueName 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.3
The name of Queue used at the time of printing by lpd. The value of Default depends on a model. Default shall be '-' (hyphen) when printing function has no relation to the name of Queue.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

mltNetLpdQueueDescr 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.4
It recommends describing the information which serves as help when a user performs a setup for lpr printing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetLpdQueueFilter 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.5
Selects Filter function set as Queue by Bitmap. When there is no Filter function in Queue, shall always be 0. Each bit in the integer is defined as follows. bit Value Filter --- ----- --------- 0 1 FF (Form Feed) 1 2 LF (Line Feed) 2 4 CR (Carriage Return) 3 8 PS (Add PostScript Header) 4 16 reserved 5 32 rejectPS 6 64 rejectPCL 7 128 rejectASCIIt
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetLpdQueueBanner 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.6
A setup of BannerPage set in Queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noBanner(0), ascii(1), pcl(2), ps(3)  

mltNetLpdQueueEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.7
Sets up Enable/Disable of each Queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetFtpdGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.1
The table for showing the general information of FTP Server.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetFtpdGeneralEntry

mltNetFtpdGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetFtpdGeneralEntry  

mltNetFtpdIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.1.1.1
The index for uniquely specifying NetworkInterface to which FTP server is set up. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetFtpdEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.1.1.2
Sets up Enable/Disable of service of FTP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetFtpdPort 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.1.1.3
Specifies Port number which FTP Server uses. Default is 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetFtpdConfigTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2
The table for showing the User information connectable to FTPServer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetFtpdConfigEntry

mltNetFtpdConfigEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetFtpdConfigEntry  

mltNetFtpdConfigIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.1
The Index for uniquely specifying NetworkInterface to which each User considers as an object. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetFtpdUserIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.2
The index for uniquely showing the User. The number of Indexes depends on an implementation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetFtpdUser 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.3
Login user name of FTP Server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

mltNetFtpdUserPassWd 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.4
Password of FTP Server. When it is gotten, applying scramble to value is not accepted. About security, support by the management tool side.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

mltNetFtpdCapability 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.5
Shows the function permitted to each user on FTP Server by Bitmap. An integer bitmap value specifying FTP function information. Each bit in the integer is defined as follows. bit Value Filter --- ----- --------- 0 1 putting job & No Filter 1 2 putting job & CR-LF invert 2 4 get (status or job or Driver) 3 8 put NIC Firmware 4 16 put Printer Font 5 32 reserved
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetFtpdDescr 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.6
Explanation etc. of the function set to each user is indicated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetHttpdGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1
The table for showing the general information about HTTP Server.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetHttpdGeneralEntry

mltNetHttpdGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetHttpdGeneralEntry  

mltNetHttpdIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1.1.1
Index for uniquely showing NetworkInterface to which HTTP Server is set up. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetHttpdEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1.1.2
Sets up Enable/Disable of service of HTTP Server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetHttpdPort 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1.1.3
The port number which HTTP Server uses. Default is 80.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetHttpdDescr 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1.1.4
Indicates the information, such as a version of HTTP Server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetSmtpGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1
The table for showing the general information of SMTP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSmtpGeneralEntry

mltNetSmtpGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetSmtpGeneralEntry  

mltNetSmtpIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1.1.1
The index for uniquely specifying NetworkInterface to which SMTP is set. The value of Index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSmtpEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1.1.2
Sets up Enable/Disable of service of SMTP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetSmtpServerAddress 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1.1.3
Shows the IP address of SMTP Server. Considering about specification by Domain name, it is made into DisplayString. In the case of specifying by the IP address, it shall be handled as a character string of maximum 15 characters of 'xxx.xxx.xxx.xxx'. Whether to accept a setup by Domain name is dependent on an implementation of a model.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltNetSmtpPort 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1.1.4
Specifies Port number which SMTP uses. Default is 25.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetSmtpAccountTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2
The table for showing Account information of SMTP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSmtpAccountEntry

mltNetSmtpAccountEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetSmtpAccountEntry  

mltNetSmtpAccountIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.1
The index for uniquely specifying NetworkInterface to which each From setup makes into the object. The value of Index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSmtpAccountIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.2
The index for uniquely showing e-mail From address setup. Although the number of index depends on an implementation, index of the number of functions in which EP-NET and Scan function etc. are supporting needs to be prepared in Default.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSmtpFromAddress 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.3
The address of From Field used by SMTP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..129)  

mltNetSmtpReplyAddress 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.4
The address of RepryTo used by SMTP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..129)  

mltNetSmtpConnTimeout 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.5
Timeout setup in SMTP. A unit is second. It shall be possible to set the number between 30-300. Default is 60 (seconds).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetSmtpPurpose 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.6
Displays the use of From setup of SMTP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(0), epNet(1), scanFunction(2)  

mltNetSmtpDescription 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.7
Description of each From setup. Default is dependent on an implementation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetIppGeneral 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1
OBJECT IDENTIFIER    

mltNetIppPrtDescrAttribute 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2
OBJECT IDENTIFIER    

mltNetIppJobTemplateAttribute 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3
OBJECT IDENTIFIER    

mltNetIppGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.1
The table for showing the general information of IPP.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetIppGeneralEntry

mltNetIppGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.1.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltNetIppGeneralEntry  

mltNetIppGeneralIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.1.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of Index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetIppServiceEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.1.1.2
Sets up Enable/Disable of service of IPP
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetIppDefaultPortIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.1.1.3
mltNetIppPortIndex which shows Default Port number used by IPP.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetIppPortTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.2
The table for showing Port information of IPP.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetIppPortEntry

mltNetIppPortEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.2.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltNetIppPortEntry  

mltNetIppPortIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.2.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of Index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetIppPortIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.2.1.2
The index for uniquely showing Port.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetIppPortNumber 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.2.1.3
Port number. '631' is supported at least.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetIppPrtDescGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1
The table for showing the general information about Printer Description Attribute of IPP.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetIppPrtDescGeneralEntry

mltNetIppPrtDescGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltNetIppPrtDescGeneralEntry  

mltIppPrtDescGeneralIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.1
Index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppPrtName 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.2
'printer-name' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..127)  

mltIppPrtMoreInfo 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.3
'printer-more-info' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..127)  

mltIppPrtState 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.4
'printer-state' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER idle(3), processing(4), stopped(5)  

mltIppCharSetConfiguredIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.5
Index which shows 'charset-configured.'
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppNaturalLanguageConfiguredIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.6
'natural-language-configured' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppDocFormatDefaultIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.7
'document-format-default' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

mltIppPrinterIsAcceptingJobs 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.8
'printer-is-accepting-jobs' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltIppQueuedJobCount 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.9
'queued-job-count' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

mltIppColorSupported 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.10
'color-supported' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltIppPdlOverrideSupported 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.11
'pdl-override-supported' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER attempted(3), notAttempted(4)  

mltIppPrinterUpTime 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.12
'printer-up-time' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  TimeTicks  

mltIppPrtLocation 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.13
'printer-location' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..127)  

mltIppPrinterCurrentTime 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.21
'printer-current-up-time' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  DateAndTime  

mltIppUriSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2
The table for showing 'printer-uri-authentication-supported' and 'printer-uri-security-supported' to 'printer-uri-supported' attribute and each 'printer-uri'.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppUriSupportedEntry

mltIppUriSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppUriSupportedEntry  

mltIppUriIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1.1
Index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppUriIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1.2
Index for uniquely showing 'printer-uri'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppUri 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1.3
'printer-uri' to support is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

mltIppUriSecurity 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1.4
'printer-uri-security' to 'printer-uri' to support is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER none(3), ssl3(4), tls(5)  

mltIppUriAuthentication 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1.5
'printer-uri-authentication' to 'printer-uri' to support is shown. This item is an IPP Ver1.1 support item. In implementation of IPP Ver1.0, it is not necessary to implement this item.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER none(3), requestingUserName(4), basic(5), digest(6), certificate(7)  

mltIppPrtStateReasonsTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3
The table which shows 'printer-state-reasons' attribute.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppPrtStateReasonsEntry

mltIppPrtStateReasonsEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppPrtStateReasonsEntry  

mltIppPrtStateReasonIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppPrtStateReasonIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3.1.2
Index for uniquely showing 'printer-state-reasons'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppPrinterStateReason 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3.1.3
'printer-state-reasons' attribute is shown. mltIppPrtStateReasonSuffix shows suffix of '-report', '-warning', and '-error'
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(2), none(3), mediaNeeded(4), mediaJam(5), movingToPaused(6), paused(7), shutDown(8), connectingToDevice(9), timedOut(10), stopping(11), stoppedPartly(12), tonerLow(13), tonerEmpty(14), spoolAreaFull(15), coverOpen(16), interlockOpen(17), doorOpen(18), inputTrayMissing(19), mediaLow(20), mediaEmpty(21), outputTrayMissing(22), outputAreaAlmostFull(23), outputAreaFull(24), markerSupplyLow(25), markerSupplyEmpty(26), markerWasteAlmostFull(27), markerWasteFull(28), fuserOverTemp(29), fuserUnderTemp(30), opcNearEndOfLife(31), opcLifeOver(32), developerLow(33), developerEmpty(34), interpreterResourceUnavailable(35)  

mltIppPrtStateReasonSuffix 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3.1.4
Three suffixes ('-report', '-warning', and '-error') of 'printer-state-reasons' attribute are shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER report(3), warning(4), error(5)  

mltIppVersionsSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.4
Table which shows 'ipp-versions-supported.' This item is an IPP Ver1.1 support item. In implementation of IPP Ver1.0, it is not necessary to implement this item.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppVersionsSupportedEntry

mltIppVersionsSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.4.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppVersionsSupportedEntry  

mltIppVersionIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.4.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppVersionIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.4.1.2
Index for uniquely showing 'ipp-version'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppVersionType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.4.1.3
'ipp-version' to support is shown
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ipp10(3), ipp11(4)  

mltIppOperationSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5
Table which has 'operation-supported' attribute.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppOperationSupportedEntry

mltIppOperationSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppOperationSupportedEntry  

mltIppOperationIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppOperationIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5.1.2
Index which shows 'operation' to support.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppOperationType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5.1.3
Type of 'operation' is shown
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER printJob(2), printURI(3), validateJob(4), createJob(5), sendDocument(6), sendURI(7), cancelJob(8), getJobAttributes(9), getJobs(10), getPrinterAttributes(11), holdJobs(12), releaseJob(13), restartJob(14), pausePrinter(16), resumePrinter(17), purgeJobs(18)  

mltIppOperationEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5.1.4
This shows Opeartor's Enable/Disable.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltIppCharSetSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6
Table which shows 'charset-supported.'
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppCharSetSupportedEntry

mltIppCharSetSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppCharSetSupportedEntry  

mltIppCharSetIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppCharSetIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6.1.2
Index for uniquely showing 'charset'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppCharSetName 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6.1.3
A parameter should follow regulation of IANA of the following. http://www.iana.org/assignments/character-set
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

mltIppCharSetCode 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6.1.4
The code of 'charset' to support A parameter should follow regulation of IANA of the following. http://www.iana.org/assignments/character-set
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppNaturalLanguageSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.7
Table which shows 'generated-natural-language-supported' attribute.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppNaturalLanguageSupportedEntry

mltIppNaturalLanguageSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.7.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppNaturalLanguageSupportedEntry  

mltIppNaturalLangIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.7.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppNaturalLangIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.7.1.2
Index for uniquely showing 'natural-language'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppNaturalLangName 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.7.1.3
The name of 'natural-language' to support.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

mltIppDocFormatSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.8
Table which shows 'document-format-supported' attribute.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppDocFormatSupportedEntry

mltIppDocFormatSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.8.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppDocFormatSupportedEntry  

mltIppDocFormatIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.8.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppDocFormatIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.8.1.2
The index for uniquely showing 'document-format'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppDocFormatName 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.8.1.3
The name of 'document-format' to support is shown
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

mltIppCompressionSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.10
Table which shows 'compression-supported.'
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppCompressionSupportedEntry

mltIppCompressionSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.10.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppCompressionSupportedEntry  

mltIppCompressionIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.10.1.1
Index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppCompressionIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.10.1.2
Index for uniquely showing 'compression'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppCompressionType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.10.1.3
'compression' currently supported is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER none(3), deflate(4), gzip(5), compress(6)  

mltNetIppJobTemplateGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1
The table for showing the general information about Job Template Attribute of IPP.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetIppJobTemplateGeneralEntry

mltNetIppJobTemplateGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltNetIppJobTemplateGeneralEntry  

mltIppJobTemplateGeneralIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppJobPriorityDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.2
'job-priority-default' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppJobPrioritySupported 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.3
'job-priority-supported' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppJobHoldUntilDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.4
'job-hold-until-default' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppJobSheetsDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.5
'ipp-job-sheets-default' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppCopiesDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.6
'copies-default' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

mltIppCopiesMaxSupported 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.7
'copies-supported' attribute is shown. Since MIN value is surely 1, only MAX is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppFinishingsDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.8
'finishings-default' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppPageRangesSupported 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.9
'page-ranges-supported' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltIppSidesDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.10
'sides-default' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

mltIppNumberUpDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.11
'number-up-default' attribute is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppOrientationRequestedDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.12
'orientation-requested-default' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

mltIppMediaDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.13
'media-default' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

mltIppPrinterResolutionDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.14
'printer-resolution-default' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

mltIppPrintQualityDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.15
'print-quality-default' attribute is shown.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

mltIppJobHoldUntilSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.2
Table which shows 'job-hold-until-supported' attribute.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppJobHoldUntilSupportedEntry

mltIppJobHoldUntilSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.2.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppJobHoldUntilSupportedEntry  

mltIppJobHoldUntilIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.2.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppJobHoldUntilIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.2.1.2
Index for uniquely showing 'job-hold-until'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppJobHoldUntilType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.2.1.3
Type of 'job-hold-until' to support.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER noHold(3), indefinite(4), dayTime(5), evening(6), night(7), weekend(8), secondShift(9), thirdShift(10)  

mltIppJobSheetsSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.3
Table which shows 'ipp-job-sheets-supported'.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppJobSheetsSupportedEntry

mltIppJobSheetsSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.3.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppJobSheetsSupportedEntry  

mltIppJobSheetsIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.3.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppJobSheetsIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.3.1.2
Index for uniquely showing 'job-sheets'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppJobSheetsType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.3.1.3
Type of 'job-sheets' to support is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER none(3), standard(4)  

mltIppFinishingsSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.4
Table which shows 'finishings-supported'.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppFinishingsSupportedEntry

mltIppFinishingsSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.4.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppFinishingsSupportedEntry  

mltIppFinishingsIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.4.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppFinishingsIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.4.1.2
Index for uniquely showing 'finishings'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppFinishingsType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.4.1.3
Type of 'finishings' to support.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER none(3), staple(4), punch(5), cover(6), bind(7), saddle-stitch(8), edge-stitch(9), staple-top-left(20), staple-bottom-left(21), staple-top-right(22), staple-bottom-right(23), edge-stitch-left(24), edge-stitch-top(25), edge-stitch-right(26), edge-stitch-bottom(27), staple-dual-left(28), staple-dual-top(29), staple-dual-right(30), staple-dual-bottom(31)  

mltIppSidesSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.5
Table which shows 'sides-supported' attribute.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppSidesSupportedEntry

mltIppSidesSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.5.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppSidesSupportedEntry  

mltIppSidesIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.5.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppSidesIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.5.1.2
Index for uniquely showing 'sides'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppSidesType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.5.1.3
Type of 'sides' to support
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER one-sided(3), two-sided-long-edge(4), two-sided-short-edge(5)  

mltIppNumberUpSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.6
Table which shows 'number-up-supported'.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppNumberUpSupportedEntry

mltIppNumberUpSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.6.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppNumberUpSupportedEntry  

mltIppNumberUpIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.6.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppNumberUpIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.6.1.2
Index for uniquely showing 'number-up'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppNumberUpType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.6.1.3
The 'number-up' value to support is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER num1Up(1), num2Up(2), num4Up(3), num9Up(4), num16Up(5)  

mltIppOrientationRequestedSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.7
'orientation-requested-supported' attribute is shown.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppOrientationRequestedSupportedEntry

mltIppOrientationRequestedSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.7.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppOrientationRequestedSupportedEntry  

mltIppOrientationRequestedIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.7.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppOrientationRequestedIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.7.1.2
Index for uniquely showing 'orientation-requested'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppOrientationRequestedType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.7.1.3
Type of 'orientation-requested' to support.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER portrait(3), landscape(4), reverse-landscape(5), reverse-portrait(6)  

mltIppMediaSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8
Table which shows 'media-supported' attribute.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppMediaSupportedEntry

mltIppMediaSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltIppMediaSupportedEntry  

mltIppMediaIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppMediaIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.2
Index for uniquely showing 'media'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltIppMediaName 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.3
The name of 'media' currently supported. Refer to Bergman, R, 'Media Size Standardized Names', PWG Draft Standard D0.5, March 26, 2001.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

mltIppMediaType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.4
mediatype of 'media' currently supported.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

mltIppMediaColor 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.5
The color of 'media' currently supported.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

mltIppMediaInputTray 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.6
Tray to which 'media' currently supported is set.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

mltPrinterResolutionSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9
Table which shows 'printer-resolution-supported'.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrinterResolutionSupportedEntry

mltPrinterResolutionSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltPrinterResolutionSupportedEntry  

mltPrinterResolutionIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltPrinterResolutionIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1.2
Index for uniquely showing 'printer-resolution'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltPrinterResolutionFeedDir 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1.3
The value of Feed direction of 'printer-resolution' to support.
Status: optional Access: read-only
OBJECT-TYPE    
  Integer32  

mltPrinterResolutionXFeedDir 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1.4
The value of XFeed direction of 'printer-resolution' to support.
Status: optional Access: read-only
OBJECT-TYPE    
  Integer32  

mltPrinterResolutionUnit 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1.5
Unit of 'printer-resolution' to support .
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(1), tenThousandthsOfInches(3), micrometers(4)  

mltPrintQualitySupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.10
Table which shows 'print-quality-supported' attribute
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrintQualitySupportedEntry

mltPrintQualitySupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.10.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltPrintQualitySupportedEntry  

mltPrintQualityIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.10.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltPrintQualityIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.10.1.2
Index for uniquely showing 'print-quality'.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltPrintQualityType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.10.1.3
Type of 'print-quality' to support.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER draft(3), normal(4), high(5)  

mltNetSlpGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1
Table for showing the general information of SLP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSlpGeneralEntry

mltNetSlpGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetSlpGeneralEntry  

mltNetSlpIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.1
The index for uniquely specifying NetworkInterface to which SLP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSlpEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.2
Enable/Disable of service of SLP is set up.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetSlpPortNumber 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.3
Port number of SLP is shown. Default is 427.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetSlpMTU 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.4
MTU value of LP gas is shown. Default shall be 1400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetSlpTTL 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.5
TTL value of SLP is shown. Default shall be 255.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetSlpBroadcastSupport 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.6
Support of multicasting and broadcasting is shown.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER broadcastOnly(1), multicastOnly(2), both(3)  

mltNetSlpConfigTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2
The table for showing the setup information of SLP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSlpConfigEntry

mltNetSlpConfigEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetSlpConfigEntry  

mltNetSlpConfigIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1.1
The index for uniquely specifying NetworkInterface to which SLP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSlpIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1.2
Index for showing a specific entry. Default is 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSlpService 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1.3
The character string which shows the service registered into DA. Example: 'service:printer:help'
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetSlpScope 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1.4
The character string which shows the scope of SLP. Default character string is 'default'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetSlpLifetime 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1.5
The value which shows LifeTime of a registration. A unit is second. Default is 10800 (3 hours).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetNwGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.8.1
Table with the basic information of NetWare relation which NetworkInterface has
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetNwGeneralEntry

mltNetNwGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.8.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetNwGeneralEntry  

mltNetNwIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.1.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetNwDefault 1.3.6.1.4.1.2590.1.1.2.1.5.8.1.1.2
The command which restores all setup about NetWare to FactoryDefault. When resetToDefault(2) is set, an agent side shall surely return Reply. In principle, when resetToDefault(2) is set, about the timing in which the setup returns to default depends on an implementation and it does not define in MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), resetToDefault(2)  

mltNetNwFrameTypeConfig 1.3.6.1.4.1.2590.1.1.2.1.5.8.1.1.3
A setup of FrameType used by NetWare (IPX). It is set by using Bitmap of the following. 1 (Auto-Sense) is recommended for the Default. Although Auto-Sense and other value do not exist together, about Binding two or more FrameTypes simultaneously, it is dependent on the implementation of a model. Bit Value FrameType ---- ---- ---------- 0 1 Reserved 1 2 802.3 2 4 EthernetII 3 8 802.3-SNAP 4 16 802.2 (4) 5 32 Reserved 6 64 802.5-TokenRing 7 128 TokenRing-SNAP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetNwPrintMode 1.3.6.1.4.1.2590.1.1.2.1.5.8.1.1.4
The mode of NetworkInterface used by NetWare is set up. Default shall be pServerMode(1). When not supporting NPrinter, it shall be the implementation of RO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pServerMode(1), nPrinterMode(2)  

mltNetNwFrameTable 1.3.6.1.4.1.2590.1.1.2.1.5.8.2
The information of FrameType which is working in NetWare is shown.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetNwFrameEntry

mltNetNwFrameEntry 1.3.6.1.4.1.2590.1.1.2.1.5.8.2.1
Status: optional Access: not-accessible
OBJECT-TYPE    
  MltNetNwFrameEntry  

mltNetNwFrameIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.2.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetNwFrameIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.2.1.2
Index for showing FrameType which is operating by NetworkInterface.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetNwFrameType 1.3.6.1.4.1.2590.1.1.2.1.5.8.2.1.3
FrameType is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ethernet8023(1), ethernetII(2), ethernetSnap(3), ethernet8022(4), tokenRing8025(6), tokenRingSnap(7)  

mltNetNwNetworkNumber 1.3.6.1.4.1.2590.1.1.2.1.5.8.2.1.4
Network number which each FrameType is using is displayed. The notation of a number is indicated by Hexadecimal numbers.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

mltNetNwPserverTable 1.3.6.1.4.1.2590.1.1.2.1.5.8.3
The table for showing the setup of PrintServer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetNwPserverEntry

mltNetNwPserverEntry 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetNwPserverEntry  

mltNetNwPsIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetNwPsIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.2
Index for uniquely showing PrintServer. The number of indexes depends on an implementation. The number of indexes which can be implemented and the number of defaults depends on an implementation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetNwPsName 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.3
The name of PrintServer. Default is dependent on an implementation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltNetNwPsPasswd 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.4
Password of PrintServer. Default is Null. When it is gotten, applying scramble to value is not accepted. About security, support by the management tool side.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltNetNwPsMode 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.5
The mode in which PrintServer supports is shown.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER both(0), binderyMode(1), ndsMode(2)  

mltNetNwPsPrefFServer 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.6
Value of Preferred FileServer used in Bindery mode. It shall be NullString when set only to NDS mode. In the system which does not set up PreferredFileServer, implement '-' (hyphen) and shall be RO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..47)  

mltNetNwPsPrefTree 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.7
Value of Preferred Tree used in NDS mode. It shall be NullString when set only to Bindery mode. In the system which does not set up PreferredTree, implement 'N/A' and shall be RO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltNetNwPsPrefContext 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.8
Value of Preferred Context used in NDS mode. It shall be NullString when set only to Bindery mode. In the system which does not set up PreferredContext, implement 'N/A' and shall be RO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..191)  

mltNetNwPsPollingRate 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.9
The interval at which PrinteServer scans Queue. Unit is second. Range which can be set up shall be 1 - 65535. Default is 1 (second).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetNwQueueTable 1.3.6.1.4.1.2590.1.1.2.1.5.8.4
Table which shows the information of Queue which NetworkInterface has managed.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetNwQueueEntry

mltNetNwQueueEntry 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetNwQueueEntry  

mltNetNwQueueIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1.1
The index for uniquely showing Queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetNwQueueName 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1.2
The name of Queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltNetNwQueueRefIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1.3
NetworkInterface which is managing Queue is shown. Use the value of mltNetNwPsIfIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetNwQueueRefPsIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1.4
PrintServer which is managing Queue is shown. Use the value of mltNetNwPsIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetNwQueueStatus 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1.5
The state of Queue is shown.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), available(1), allocated(2), inUse(3)  

mltNetNwNPrinterTable 1.3.6.1.4.1.2590.1.1.2.1.5.8.5
Table which shows the information of NPrinter which NetworkInterface is managing. In the system without Nprinter function, it is not necessary to implement this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetNwNPrinterEntry

mltNetNwNPrinterEntry 1.3.6.1.4.1.2590.1.1.2.1.5.8.5.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetNwNPrinterEntry  

mltNetNwNPrinterIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.5.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetNwNPrinterIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.5.1.2
Index for uniquely showing Nprinter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetNwNPrinterName 1.3.6.1.4.1.2590.1.1.2.1.5.8.5.1.3
The name of Nprinter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltNetNwNPrinterNumber 1.3.6.1.4.1.2590.1.1.2.1.5.8.5.1.4
Printer number of NPrinter. Default shall be 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltNetAppleTalkGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.9.1
Table with the basic information of AppleTalk relation which NetworkInterface has.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetAppleTalkGeneralEntry

mltNetAppleTalkGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetAppleTalkGeneralEntry  

mltNetAtIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetAtDefault 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.2
The command which restores all setup about AppleTalk to FactoryDefault. When resetToDefault(2) is set, an agent side shall surely return Reply. In principle, when resetToDefault(2) is set, about the timing in which the setup returns to default depends on an implementation and it does not define in MIB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), resetToDefault(2)  

mltNetAtNetNumber 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.3
NetworkNumber in Network of AppleTalk. Display the value acquired at the time of Apple Talk starting. When it is unknown, shall be -2 (unknown).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetAtNodeNumber 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.4
Node Number in Network of AppleTalk. Display the value acquired at the time of Apple Talk starting. When it is unknown, shall be -2 (unknown).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetAtDesiredZone 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.5
Setting value of Zone name in Apple Talk. Default shall be '*'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetAtCurrentZone 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.6
Zone name to which device is operating. In environment of operation, it may differ from the above-mentioned value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetAtPrinterTable 1.3.6.1.4.1.2590.1.1.2.1.5.9.2
The table for showing the setup of AppleTalkPrinter.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetAtPrinterEntry

mltNetAtPrinterEntry 1.3.6.1.4.1.2590.1.1.2.1.5.9.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetAtPrinterEntry  

mltNetAtPrinterIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.9.2.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetAtPrinterIndex 1.3.6.1.4.1.2590.1.1.2.1.5.9.2.1.2
The index for uniquely showing AppleTalkPrinter. The number of indexed depends on an implementation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetAtPrinterName 1.3.6.1.4.1.2590.1.1.2.1.5.9.2.1.3
The name of AppleTalkPrinter. When performing the operation, the name in an actual operation environment should be shown.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

mltNetAtPrinterType 1.3.6.1.4.1.2590.1.1.2.1.5.9.2.1.4
Type of AppleTalk Printer. Default is 'LaserWriter'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetSmbGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.10.1
The table with the basic information of SMB relation which NetworkInterface has.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSmbGeneralEntry

mltNetSmbGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetSmbGeneralEntry  

mltNetSmbIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSmbDefault 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.2
The command which restores all setup about SMB to FactoryDefault. When resetToDefault(2) is set, an agent side shall surely return Reply. In principle, when resetToDefault(2) is set, about the timing in which the setup returns to default depends on an implementation and it does not define in MIB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), resetToDefault(2)  

mltNetSmbWorkGroupName 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.3
WorkGroup name in Windows Network. Default shall be 'WORKGROUP'. Only the implementation of capital letters is accepted about this item.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetSmbHostName 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.4
Host name in Windows Network. Default is dependent on an implementation. Only the implementation of capital letters is accepted about this item
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetSmbWinsSupport 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.5
Sets up the availability of use of WINS. Default is disable(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(0), enable(1), disable(2)  

mltNetSmbWinsPrimaryServer 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.6
Sets up PrimaryServer of Wins. Default is 0.0.0.0
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

mltNetSmbWinsSecondaryServer 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.7
Sets up Secondary Server of Wins. Default is 0.0.0.0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

mltNetSmbPrinterTable 1.3.6.1.4.1.2590.1.1.2.1.5.10.2
The table which has the information of Printer relation in SMB.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSmbPrinterEntry

mltNetSmbPrinterEntry 1.3.6.1.4.1.2590.1.1.2.1.5.10.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltNetSmbPrinterEntry  

mltNetSmbPrinterIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.10.2.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSmbPrinterIndex 1.3.6.1.4.1.2590.1.1.2.1.5.10.2.1.2
Index for uniquely showing Printer in SMB. The number of indexes depends on an implementation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltNetSmbPrinterName 1.3.6.1.4.1.2590.1.1.2.1.5.10.2.1.3
Printer name in SMB. Default is dependent on the implementation of a model. About the availability of Printer name change shall also be dependent on an implementation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltNetSmbPrinterDescr 1.3.6.1.4.1.2590.1.1.2.1.5.10.2.1.4
Explanation of Printer. About the written contents is dependent on the implementation of a model; however, implementation of NullString is not accepted. At least input the character string which is same as Default Printer name.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltJmMibVersion 1.3.6.1.4.1.2590.1.1.4.1.1
The standardization version of MIB implemented in JobManagement relation. This indicates the version of the Private Job Management MIB that is implemented. There are some mib objects that indicate the Mib Version. (mltSysMibVersion, mltPrtMibVersion, mltScnMibVersion, mltNetMiIbVersion, mltJmMibVersion) But, the each mib version should be same version. Especially, the each major versions must be same. The version information of Standard MIB specification. General form is AA.BC. AA is indicating major revision, and B and C is minor revision. Decimal point is ASCII-coded period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..7)  

mltJmGeneral 1.3.6.1.4.1.2590.1.1.4.1.2
OBJECT IDENTIFIER    

mltJmJob 1.3.6.1.4.1.2590.1.1.4.1.3
OBJECT IDENTIFIER    

mltJmReport 1.3.6.1.4.1.2590.1.1.4.1.4
OBJECT IDENTIFIER    

mltJmGeneralTable 1.3.6.1.4.1.2590.1.1.4.1.2.1
This table indicates the general information about Job Management. This table contains the number of active jobs, oldest/newest jobs, the number of preservation of a history, and so on.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltJmGeneralEntry

mltJmGeneralEntry 1.3.6.1.4.1.2590.1.1.4.1.2.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltJmGeneralEntry  

mltJmGeneralJobSetIndex 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.1
A unique value for each job set in this MIB. JobSet shows the system of the serial number used for Job management. In managing a serial number to 1 by all the functions of a device according to 'Job management standard specifications', it sets the number of JobSets to 1. In managing a serial number for every functional classification, only the number of functional classifications shall have JobSet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltJmGeneralNumberOfActiveJobs 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.2
The current number of 'active' jobs in the mltJmJobTable. when the device has no active jobs, this value should be 0. The device that cannot support to count active jobs should implement (-2) as fixed value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltJmGeneralOldestActiveJobIndex 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.3
The mltJmJobIndex of the oldest job that is still in one of the 'active' states. In other words, the index of the 'active' job that has been in the job tables the longest. If there are no active jobs, this value should be 0. The device that cannot support to count active jobs should implement (-2) as fixed value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltJmGeneralNewestActiveJobIndex 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.4
The mltJmJobIndex of the newest job that is in one of the 'active' states. In other words, the index of the 'active' job that has been most recently added to the job tables. If there are no active jobs, this value should be 0. The device that cannot support to count active jobs should implement (-2) as fixed value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltJmGeneralJobPersistence 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.5
The number holding the information (Index) on Job is specified after an end of Job. About the number which should hold the history information on Job, it shall be dependent on implementation of a model. If a device can not support this, '-2'(Not Support) should be implemented.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltJmGeneralJobSetType 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.6
The type of JobSet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER mfpAll(0), copy(1), print(2), receiveJob(3), sendJob(4), faxReceive(5), faxSend(6), other(7)  

mltJmJobTable 1.3.6.1.4.1.2590.1.1.4.1.3.1
The table indicates the detailed information of jobs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltJmJobEntry

mltJmJobEntry 1.3.6.1.4.1.2590.1.1.4.1.3.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltJmJobEntry  

mltJmJobJobSetIndex 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.1
A unique value for each job set in this MIB. JobSet shows the system of the serial number used for Job management. This index is the same as mltJmGeneralJobSetIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltJmJobIndex 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.2
The sequential, monotonously increasing identifier index for the job generated by the device when that device accepted the job. [ This Index shall hold also in power supply On./Off. After attainment is automatically re-started from 1 to maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

mltJmJobFunction 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.3
This value indicates the function of job sender. receiveJob(3) may include FAX and iFAX jobs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), copy(1), print(2), receiveJob(3), sendJob(4), faxReceive(5), faxSend(6), other(7)  

mltJmJobStatus 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.4
This value indicates the status of job.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(0), other(1), cancelRequest(2), puaseRequest(3), restartRequest(4), pending(10), pendingHeld(11), pendingPaused(12), processing(20), sending(21), receiving(22), printing(23), scanning(24), processingStopped(25), completed(30), caution(31), aborted(32), canceled(33)  

mltJmJobReceivedTime 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.6
Registration time of Job. About TimeZone, it is not indispensable. When you cannot perform acquisition of time information, be referred to as Null (Zero-Length).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DateAndTime  

mltJmJobCompleteTime 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.7
Completion time of Job. About TimeZone, it is not indispensable. When you await and completion time cannot be written by Job etc., be referred to as Null (Zero-Length).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DateAndTime  

mltJmJobPriority 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.8
It is used when controlling the priority of Job. When device cannot support to change of a priority, this value should be notSupported (0) as RO. When device support to change of a priority, it uses the value of 1 to 5. In this case, implementation as RW is mandatory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(0), lowestPriority(1), lowPriority(2), normalPriority(3), highPriority(4), highestPriority(5)  

mltJmJobDivNumber 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.9
The division number of job. 0-999 is used. When the device does not perform division control, this value should be (-2). (-2) means unknown.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltJmJobOwner 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.10
The owner of job. If device cannot detect the name of owner , this value should be '-', of 'unknown'. The implementation of zero-length is not accepted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltJmJobType 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.11
The type of job. When the job type is not detected, this value should be other(0).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(0), eMail(11), iFaxSend(12), scanToServer(13), scanToPC(14), scanToHDD(15), twain(16), normalPrint(20), ippPrint(21), securePrint(22), timerPrint(23), printToHDD(24), proofAndPrint(25), reportPrint(29), iFaxReceive(31), normalCopy(40), faxRecieved(51), faxSend(52)  

mltJmJobName 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.12
The name of job. If device cannot detect job name, this value should be '-', of 'unknown'. The implementation of zero-length is not accepted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

mltJmJobDocPageNumbers 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.13
The page numbers of job. When device cannot detect page numbers this value should be (-2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

mltJmJobDocCopyNumbers 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.14
Number of copies of Job. When device cannot detect the number of copies, this value should be (-2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

mltJmJobPageSize 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.15
The paper/picture size of Job. In case of output job, this value shows output paper size. Incase of scanned job, this value shows the size of picture. In Job of mixed size, the last page should be displayed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER otherPaperSize(0), unknownPaperSize(1), a0(11), a1(12), a2(13), a3(14), a4(15), a5(16), a6(17), b0(21), b1(22), b2(23), b3(24), b4(25), b5(26), b6(27), us12x14(30), ledger(31), us11x15(32), us11x14(33), comp(34), us10x14(35), us9-1by4x14(36), legal(37), us8-1by4x11-3by4(38), letter(39), govLetter(40), quarto(41), executive(42), statement(43), govRegal(44), us3x5(46), us4x6(47), fls(50), fls0(51), fls1(52), fls2(53), fls3(54), hagaki(61), oufuku-Hagaki(62), envelopeB5(63), envelopeCom10(64), envelopeC5(65), envelopeDL(66), envelopeMonarch(67), envelopeC6(68), youkei-0Gou(70), youkei-1Gou(71), youkei-4Gou(74), youkei-6Gou(76), choukei-3Gou(83), choukei-4Gou(84), kakugata-3Gou(93), a3W(114), a4W(115), a5W(116), a6W(117)  

mltJmJobDestination 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.16
The destination of job. If destination is unknown, this value should be '-'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

mltJmJobDataSize 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.18
The data size of job. A unit is KByte. In case of printing job, this value should be the size of printing date. In case of send job, this value should be not the size of picture but the size of transefered data. When the device cannot detect data size, this value should be (-2).
Status: optional Access: read-only
OBJECT-TYPE    
  Integer32  

mltJmJobColorMode 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.19
The type of color mode.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(0), unknown(1), color(2), grayScale(3), blackWhite(4)  

mltJmJobFormat 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.20
The data format of job.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(0), unknown(1), raw(2), tiff(3), tiff-MH(4), tiff-MR(5), tiff-MMR(6), jpeg(7), pdf(8), pcl(9), postScript(10), gdi(11), linePrinter(12)  

mltJmJobXResolution 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.21
Resolution of the X direction of Job. A unit is dpi.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltJmJobYResolution 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.22
Resolution of the Y direction of Job. A unit is dpi.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

mltJmJobDuplex 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.23
A duplex setting of job.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

mltJmJobOutputPages 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.25
The page numbers which the output ended in Job. If a device can not recognize this information, '-2'(Not Support) should be implemented.
Status: optional Access: read-only
OBJECT-TYPE    
  Integer32  

mltJmJobOutputSheets 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.26
The sheets numbers which the output ended in Job. If a device can not recognize this information, '-2'(Not Support) should be implemented.
Status: optional Access: read-only
OBJECT-TYPE    
  Integer32  

mltJmJobMediaType 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.27
The media type of job.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER otherMediaType(208), unknownMediaType(209), plainPaper(210), plainPaper2side(211), plainPaperRecycled(212), plainPaperExclusive(214), plainPaperColor(216), thick1(222), thick1-2side(223), thick2(224), thick2-2side(225), thick3(226), thick3-2side(227), ohp(230), thin(236), envelope(240), envelope-2side(241), label(242), postCard(244), letterHead(246), tab(248)  

mltJmReportTable 1.3.6.1.4.1.2590.1.1.4.1.4.1
Table for setting up the report of job history management information. If a device does not support all this functions, this table needs not to be implemented.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MltJmReportEntry

mltJmReportEntry 1.3.6.1.4.1.2590.1.1.4.1.4.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MltJmReportEntry  

mltJmReportIndex 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.1
A unique value for each report destinations.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mltJmReportAddress 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.2
E-mail address of report destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..129)  

mltJmKeepAliveCount 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.3
The counter that controls existence of transmission to Job history information. Default shall set to 0 and, in 0, it shall not transmit to the specified address. A positive number is set when demanding transmission of Job history information. Transmission will be stopped, if it subtracts every 1 and is set to 0, whenever this counter will pass on the 1st. The side that demands transmission of Job history information makes transmission continue by rewriting this counter periodically. Moreover, when E-mail environment is not ready (grade to which the SMTP server is not set), display -1. When there is no transmitting control function, this value should be -3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mltJmReportInterval 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.5
The number of cases that transmits Job history at once is set up.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER notSend(0), each1(1), each10(2), each50(3), each100(4), each250(5), each500(6)  

mltJmReporIntervalSelection 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.6
The maximum of the number of cases to which once transmits Job history is shown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER notSend(0), each1(1), each10(2), each50(3), each100(4), each250(5), each500(6)  

mltJmReportRequest 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.7
The request command of reporting job history. default : 0 send request : 1
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER