MBG-SNMP-LT-MIB
File:
MBG-SNMP-LT-MIB.mib
(119264 bytes)
Imported modules
SNMPv2-SMI
SNMPv2-CONF
SNMPv2-TC
MBG-SNMP-ROOT-MIB
Imported symbols
MODULE-IDENTITY
OBJECT-TYPE
Integer32
NOTIFICATION-TYPE
MODULE-COMPLIANCE
OBJECT-GROUP
NOTIFICATION-GROUP
DisplayString
mbgSnmpRoot
Defined Values
mbgLantime
1.3.6.1.4.1.5597.3
Meinberg SNMP Management Information Base
MODULE-IDENTITY
mbgLtInfo
1.3.6.1.4.1.5597.3.0
OBJECT IDENTIFIER
mbgLtFirmwareVersion
1.3.6.1.4.1.5597.3.0.1
shows the installed firmware version of your LANTIME
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtFirmwareVersionVal
1.3.6.1.4.1.5597.3.0.2
shows the installed firmware version of your LANTIME as an Integer32 value
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtNtp
1.3.6.1.4.1.5597.3.1
OBJECT IDENTIFIER
mbgLtNtpCurrentState
1.3.6.1.4.1.5597.3.1.1
actual state of the NTP as string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtNtpCurrentStateVal
1.3.6.1.4.1.5597.3.1.2
current state of the NTP as Integer32 value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notSynchronized(0), noGoodRefclock(1), syncToExtRefclock(2), syncToSerialRefclock(3), normalOperationPPS(4), normalOperationRefclock(5), unknown(99)
mbgLtNtpStratum
1.3.6.1.4.1.5597.3.1.3
Stratum value of the NTP
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtNtpActiveRefclockId
1.3.6.1.4.1.5597.3.1.4
Index of the current refclock selected by the NTP
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
localClock(0), serialRefclock(1), pps(2), externalRefclock(3), notSync(99)
mbgLtNtpActiveRefclockName
1.3.6.1.4.1.5597.3.1.5
Name of the current refclock selected by the NTP
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtNtpActiveRefclockOffset
1.3.6.1.4.1.5597.3.1.6
Time offset between the current selected refclock and time of NTP as string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtNtpActiveRefclockOffsetVal
1.3.6.1.4.1.5597.3.1.7
Time offset in micro seconds between the current selected refclock and time of NTP
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtNtpNumberOfRefclocks
1.3.6.1.4.1.5597.3.1.8
Number of refclocks configured in the NTP
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtNtpAuthKeyId
1.3.6.1.4.1.5597.3.1.9
Authentication Key ID of active refclock is active
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtNtpVersion
1.3.6.1.4.1.5597.3.1.10
integrated NTP version
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefclock
1.3.6.1.4.1.5597.3.2
OBJECT IDENTIFIER
mbgLtRefClockType
1.3.6.1.4.1.5597.3.2.1
Type of refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefClockTypeVal
1.3.6.1.4.1.5597.3.2.2
Type of refclock connected to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), mbgGPS167(1), mbgGPS167BGTTGP(2), mbgPZF509(3), mbgPZF509BGTTGP(4), mbgSHS(5), mbgSHSBGT(6), mbgSHSFRC(7), mbgSHSFRCBGT(8), mbgTCR509(9), mbgTCR509BGTTGP(10), mbgRDT(11), mbgRDTBGTTGP(12), mbgEDT(13), mbgEDTBGTTGP(14), mbgAHS(15), mbgDHS(16), mbgNDT167(17), mbgNDT167BGT(18), mbgDCT(19), mbgDCTBGT(20), mbgSHSTCR(21), mbgSHSTCRBGT(22)
mbgLtRefClockMode
1.3.6.1.4.1.5597.3.2.3
current mode of refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefClockModeVal
1.3.6.1.4.1.5597.3.2.4
current mode of refclock connected to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), normalOperation(1), trackingSearching(2), antennaFaulty(3), warmBoot(4), coldBoot(5), antennaShortcircuit(6)
mbgLtRefGpsState
1.3.6.1.4.1.5597.3.2.5
current State of GPS refclock conneted to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefGpsStateVal
1.3.6.1.4.1.5597.3.2.6
current State of GPS refclock conneted to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), synchronized(1), notsynchronized(2)
mbgLtRefGpsPosition
1.3.6.1.4.1.5597.3.2.7
current Position of GPS refclock conneted to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefGpsSatellites
1.3.6.1.4.1.5597.3.2.8
current Satellites in view and good of GPS refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefGpsSatellitesGood
1.3.6.1.4.1.5597.3.2.9
current good Satellites of GPS refclock connected to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtRefGpsSatellitesInView
1.3.6.1.4.1.5597.3.2.10
current Satellites in view of GPS refclock conneted to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtRefPzfState
1.3.6.1.4.1.5597.3.2.11
current State of DCF77/PZF refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefPzfStateVal
1.3.6.1.4.1.5597.3.2.12
current State of DCF77/PZF refclock connected to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), sync(1), notsyncnow(2), neversynced(3)
mbgLtRefPzfKorrelation
1.3.6.1.4.1.5597.3.2.13
current Korrelation of DCF77/PZF refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
Integer32
0..255
mbgLtRefPzfField
1.3.6.1.4.1.5597.3.2.14
current strength of field of DCF77/PZF refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtRefGpsMode
1.3.6.1.4.1.5597.3.2.15
current Mode of GPS refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefGpsModeVal
1.3.6.1.4.1.5597.3.2.16
current Mode of GPS refclock connected to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), normalOperation(1), trackingSearching(2), antennaFaulty(3), warmBoot(4), coldBoot(5), antennaShortcircuit(6)
mbgLtRefIrigMode
1.3.6.1.4.1.5597.3.2.17
current Mode of IRIG refclock conneted to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefIrigModeVal
1.3.6.1.4.1.5597.3.2.18
current Mode of IRIG refclock conneted to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), locked(1), notlocked(2), telegramError(3)
mbgLtRefPzfMode
1.3.6.1.4.1.5597.3.2.19
current Mode of PZF refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefPzfModeVal
1.3.6.1.4.1.5597.3.2.20
current Mode of PZF refclock connected to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), normalOperation(1), antennaFaulty(2)
mbgLtRefIrigState
1.3.6.1.4.1.5597.3.2.21
current State of IRIG refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefIrigStateVal
1.3.6.1.4.1.5597.3.2.22
current State of IRIG refclock connected to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtRefSHSMode
1.3.6.1.4.1.5597.3.2.23
current Mode of SHS system connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefSHSModeVal
1.3.6.1.4.1.5597.3.2.24
current Mode of SHS system connected to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), normalOperation(1), stoppedTimeLimitError(2)
mbgLtRefSHSTimeDiff
1.3.6.1.4.1.5597.3.2.25
current time difference between the two SHS reference time sources in miliseconds
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtRefDctState
1.3.6.1.4.1.5597.3.2.26
current State of DCF77 refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefDctStateVal
1.3.6.1.4.1.5597.3.2.27
current State of DCF77 refclock connected to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), sync(1), notsyncnow(2), neversynced(3)
mbgLtRefDctField
1.3.6.1.4.1.5597.3.2.28
current strength of field of DCF77 refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefDctMode
1.3.6.1.4.1.5597.3.2.29
current Mode of DCF77 refclock connected to NTP time server
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefDctModeVal
1.3.6.1.4.1.5597.3.2.30
current Mode of DCF77 refclock connected to NTP time server as value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), normalOperation(1), antennaFaulty(2)
mbgLtRefGpsLeapSecond
1.3.6.1.4.1.5597.3.2.31
Date and Time of leap second announcement received via GPS
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefGpsLeapCorrection
1.3.6.1.4.1.5597.3.2.32
Leap Second Correction received via GPS
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrs
1.3.6.1.4.1.5597.3.2.50
OBJECT IDENTIFIER
mbgLtRefMrsRef
1.3.6.1.4.1.5597.3.2.50.1
ID of currently active reference source as a string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefMrsRefVal
1.3.6.1.4.1.5597.3.2.50.2
currently active reference as a value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notavailable(0), refGps(1), refIrig(2), refPps(3), refFreq(4), refPtp(5), refNtp(6), refFreeRun(99)
mbgLtRefMrsRefList
1.3.6.1.4.1.5597.3.2.50.3
List of all supported MRS references in a comma separated list
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtRefMrsPrioList
1.3.6.1.4.1.5597.3.2.50.4
List of all active MRS references in a comma separated list sorted by priority
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsRef
1.3.6.1.4.1.5597.3.2.50.10
OBJECT IDENTIFIER
mbgLtMrsRefGps
1.3.6.1.4.1.5597.3.2.50.10.1
OBJECT IDENTIFIER
mbgLtMrsGpsOffs
1.3.6.1.4.1.5597.3.2.50.10.1.1
Offset of this reference to the currently active reference, unit included in the string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsGpsOffsVal
1.3.6.1.4.1.5597.3.2.50.10.1.2
Offset of this reference to the currently active reference, unit see below
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsGpsOffsBase
1.3.6.1.4.1.5597.3.2.50.10.1.3
base of the offset value shown in mbgLtMrsGpsOffsVal
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
baseSeconds(0), baseMiliseconds(3), baseMicroseconds(6), baseNanoseconds(9)
mbgLtMrsGpsPrio
1.3.6.1.4.1.5597.3.2.50.10.1.4
the configured priority of this reference
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsGpsState
1.3.6.1.4.1.5597.3.2.50.10.1.5
the current status of this reference as a string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsGpsStateVal
1.3.6.1.4.1.5597.3.2.50.10.1.6
the current status of this reference as an Integer value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notAvailable(0), notSupported(1), notConnected(2), noSignal(3), hasLocked(4), isAvailable(5), isAccurate(6), isMaster(7)
mbgLtMrsGpsPrecision
1.3.6.1.4.1.5597.3.2.50.10.1.7
Precision Factor of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsRefIrig
1.3.6.1.4.1.5597.3.2.50.10.2
OBJECT IDENTIFIER
mbgLtMrsIrigOffs
1.3.6.1.4.1.5597.3.2.50.10.2.1
Offset of this reference to the currently active reference, unit included in the string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsIrigOffsVal
1.3.6.1.4.1.5597.3.2.50.10.2.2
Offset of this reference to the currently active reference, unit see below
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsIrigOffsBase
1.3.6.1.4.1.5597.3.2.50.10.2.3
base of the offset value shown in mbgLtMrsIrigOffsVal
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
baseSeconds(0), baseMiliseconds(3), baseMicroseconds(6), baseNanoseconds(9)
mbgLtMrsIrigPrio
1.3.6.1.4.1.5597.3.2.50.10.2.4
the configured priority of this reference
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsIrigState
1.3.6.1.4.1.5597.3.2.50.10.2.5
the current status of this reference as a string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsIrigStateVal
1.3.6.1.4.1.5597.3.2.50.10.2.6
the current status of this reference as an Integer value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notAvailable(0), notSupported(1), notConnected(2), noSignal(3), hasLocked(4), isAvailable(5), isAccurate(6), isMaster(7)
mbgLtMrsIrigCorr
1.3.6.1.4.1.5597.3.2.50.10.2.7
Correction Value (Fixed Offset) of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsIrigOffsLimit
1.3.6.1.4.1.5597.3.2.50.10.2.8
Offset Limit in nanoseconds, if exceeded this will trigger a notification
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsIrigPrecision
1.3.6.1.4.1.5597.3.2.50.10.2.9
Precision Factor of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsRefPps
1.3.6.1.4.1.5597.3.2.50.10.3
OBJECT IDENTIFIER
mbgLtMrsPpsOffs
1.3.6.1.4.1.5597.3.2.50.10.3.1
Offset of this reference to the currently active reference, unit included in the string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsPpsOffsVal
1.3.6.1.4.1.5597.3.2.50.10.3.2
Offset of this reference to the currently active reference, unit see below
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsPpsOffsBase
1.3.6.1.4.1.5597.3.2.50.10.3.3
base of the offset value shown in mbgLtMrsPpsOffsVal
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
baseSeconds(0), baseMiliseconds(3), baseMicroseconds(6), baseNanoseconds(9)
mbgLtMrsPpsPrio
1.3.6.1.4.1.5597.3.2.50.10.3.4
the configured priority of this reference
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsPpsState
1.3.6.1.4.1.5597.3.2.50.10.3.5
the current status of this reference as a string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsPpsStateVal
1.3.6.1.4.1.5597.3.2.50.10.3.6
the current status of this reference as an Integer value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notAvailable(0), notSupported(1), notConnected(2), noSignal(3), hasLocked(4), isAvailable(5), isAccurate(6), isMaster(7)
mbgLtMrsPpsCorr
1.3.6.1.4.1.5597.3.2.50.10.3.7
Correction Value (Fixed Offset) of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsPpsOffsLimit
1.3.6.1.4.1.5597.3.2.50.10.3.8
Offset Limit in nanoseconds, if exceeded this will trigger a notification
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsPpsPrecision
1.3.6.1.4.1.5597.3.2.50.10.3.9
Precision Factor of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsRefFreq
1.3.6.1.4.1.5597.3.2.50.10.4
OBJECT IDENTIFIER
mbgLtMrsFreqOffs
1.3.6.1.4.1.5597.3.2.50.10.4.1
Offset of this reference to the currently active reference, unit included in the string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsFreqOffsVal
1.3.6.1.4.1.5597.3.2.50.10.4.2
Offset of this reference to the currently active reference, unit see below
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsFreqOffsBase
1.3.6.1.4.1.5597.3.2.50.10.4.3
base of the offset value shown in mbgLtMrsFreqOffsVal
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
baseSeconds(0), baseMiliseconds(3), baseMicroseconds(6), baseNanoseconds(9)
mbgLtMrsFreqPrio
1.3.6.1.4.1.5597.3.2.50.10.4.4
the configured priority of this reference
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsFreqState
1.3.6.1.4.1.5597.3.2.50.10.4.5
the current status of this reference as a string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsFreqStateVal
1.3.6.1.4.1.5597.3.2.50.10.4.6
the current status of this reference as an Integer value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notAvailable(0), notSupported(1), notConnected(2), noSignal(3), hasLocked(4), isAvailable(5), isAccurate(6), isMaster(7)
mbgLtMrsFreqCorr
1.3.6.1.4.1.5597.3.2.50.10.4.7
Correction Value (Fixed Offset) of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsFreqOffsLimit
1.3.6.1.4.1.5597.3.2.50.10.4.8
Offset Limit in nanoseconds, if exceeded this will trigger a notification
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsFreqPrecision
1.3.6.1.4.1.5597.3.2.50.10.4.9
Precision Factor of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsRefPtp
1.3.6.1.4.1.5597.3.2.50.10.5
OBJECT IDENTIFIER
mbgLtMrsPtpOffs
1.3.6.1.4.1.5597.3.2.50.10.5.1
Offset of this reference to the currently active reference, unit included in the string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsPtpOffsVal
1.3.6.1.4.1.5597.3.2.50.10.5.2
Offset of this reference to the currently active reference, unit see below
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsPtpOffsBase
1.3.6.1.4.1.5597.3.2.50.10.5.3
base of the offset value shown in mbgLtMrsPtpOffsVal
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
baseSeconds(0), baseMiliseconds(3), baseMicroseconds(6), baseNanoseconds(9)
mbgLtMrsPtpPrio
1.3.6.1.4.1.5597.3.2.50.10.5.4
the configured priority of this reference
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsPtpState
1.3.6.1.4.1.5597.3.2.50.10.5.5
the current status of this reference as a string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsPtpStateVal
1.3.6.1.4.1.5597.3.2.50.10.5.6
the current status of this reference as an Integer value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notAvailable(0), notSupported(1), notConnected(2), noSignal(3), hasLocked(4), isAvailable(5), isAccurate(6), isMaster(7)
mbgLtMrsPtpCorr
1.3.6.1.4.1.5597.3.2.50.10.5.7
Correction Value (Fixed Offset) of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsPtpOffsLimit
1.3.6.1.4.1.5597.3.2.50.10.5.8
Offset Limit in nanoseconds, if exceeded this will trigger a notification
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsPtpPrecision
1.3.6.1.4.1.5597.3.2.50.10.5.9
Precision Factor of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsRefNtp
1.3.6.1.4.1.5597.3.2.50.10.6
OBJECT IDENTIFIER
mbgLtMrsNtpOffs
1.3.6.1.4.1.5597.3.2.50.10.6.1
Offset of this reference to the currently active reference, unit included in the string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsNtpOffsVal
1.3.6.1.4.1.5597.3.2.50.10.6.2
Offset of this reference to the currently active reference, unit see below
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsNtpOffsBase
1.3.6.1.4.1.5597.3.2.50.10.6.3
base of the offset value shown in mbgLtMrsNtpOffsVal
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
baseSeconds(0), baseMiliseconds(3), baseMicroseconds(6), baseNanoseconds(9)
mbgLtMrsNtpPrio
1.3.6.1.4.1.5597.3.2.50.10.6.4
the configured priority of this reference
Status: current
Access: read-only
OBJECT-TYPE
Integer32
mbgLtMrsNtpState
1.3.6.1.4.1.5597.3.2.50.10.6.5
the current status of this reference as a string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtMrsNtpStateVal
1.3.6.1.4.1.5597.3.2.50.10.6.6
the current status of this reference as an Integer value
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
notAvailable(0), notSupported(1), notConnected(2), noSignal(3), hasLocked(4), isAvailable(5), isAccurate(6), isMaster(7)
mbgLtMrsNtpCorr
1.3.6.1.4.1.5597.3.2.50.10.6.7
Correction Value (Fixed Offset) of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsNtpOffsLimit
1.3.6.1.4.1.5597.3.2.50.10.6.8
Offset Limit in nanoseconds, if exceeded this will trigger a notification
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtMrsNtpPrecision
1.3.6.1.4.1.5597.3.2.50.10.6.9
Precision Factor of this reference in nanoseconds
Status: current
Access: read-write
OBJECT-TYPE
Integer32
mbgLtNotifications
1.3.6.1.4.1.5597.3.3
OBJECT IDENTIFIER
mbgLtTraps
1.3.6.1.4.1.5597.3.3.0
OBJECT IDENTIFIER
mbgLtTrapNTPNotSync
1.3.6.1.4.1.5597.3.3.0.1
trap to be sent when NTP is not synchronised
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapNTPStopped
1.3.6.1.4.1.5597.3.3.0.2
trap to be sent when NTP is stopped
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapServerBoot
1.3.6.1.4.1.5597.3.3.0.3
trap to be sent when time server has finished boot sequence
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapReceiverNotResponding
1.3.6.1.4.1.5597.3.3.0.4
trap to be sent when receiver is not responding
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapReceiverNotSync
1.3.6.1.4.1.5597.3.3.0.5
trap to be sent when receiver is not synchronised
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapAntennaFaulty
1.3.6.1.4.1.5597.3.3.0.6
trap to be sent when connection to antenna is broken
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapAntennaReconnect
1.3.6.1.4.1.5597.3.3.0.7
trap to be sent when antenna has been reconnected
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapConfigChanged
1.3.6.1.4.1.5597.3.3.0.8
trap to be sent when timeserver reloaded its configuration
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapLeapSecondAnnounced
1.3.6.1.4.1.5597.3.3.0.9
trap to be sent when a leap second has been announced
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapSHSTimeLimitError
1.3.6.1.4.1.5597.3.3.0.10
trap to be sent when SHS timelimit exceeded
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapSecondaryRecNotSync
1.3.6.1.4.1.5597.3.3.0.11
trap to be sent when secondary receiver in SHS system is not synchronised
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapPowerSupplyFailure
1.3.6.1.4.1.5597.3.3.0.12
trap to be sent when one of the redundant power supplies fails
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapAntennaShortCircuit
1.3.6.1.4.1.5597.3.3.0.13
trap to be sent when a connected antenna fails due to a short circuit
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapReceiverSync
1.3.6.1.4.1.5597.3.3.0.14
trap to be sent when receiver is synchronised
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapNTPClientAlarm
1.3.6.1.4.1.5597.3.3.0.15
trap to be sent when an NTP Client Monitoring alarm occurs, e.g. when a monitored client is not reachable.
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapPowerSupplyUp
1.3.6.1.4.1.5597.3.3.0.16
trap to be sent when a power supply returned to a healthy state.
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapNetworkDown
1.3.6.1.4.1.5597.3.3.0.17
trap to be sent when a monitored network port is down.
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapNetworkUp
1.3.6.1.4.1.5597.3.3.0.18
trap to be sent when a monitored network port is up.
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapSecondaryRecNotResp
1.3.6.1.4.1.5597.3.3.0.19
trap to be sent when secondary receiver is not responding
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapXmrLimitExceeded
1.3.6.1.4.1.5597.3.3.0.30
trap to be sent when a reference offset exceeds the configured limit
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapXmrRefDisconnect
1.3.6.1.4.1.5597.3.3.0.31
trap to be sent when a reference signal has been lost
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapXmrRefReconnect
1.3.6.1.4.1.5597.3.3.0.32
trap to be sent when a reference signal recovered
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapFdmError
1.3.6.1.4.1.5597.3.3.0.33
trap to be sent when the Fdm module generates an alarm
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapSHSTimeLimitWarning
1.3.6.1.4.1.5597.3.3.0.34
trap to be sent when SHS warning limit exceeded
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapSecondaryRecSync
1.3.6.1.4.1.5597.3.3.0.35
trap to be sent when secondary receiver is synchronised
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapNTPSync
1.3.6.1.4.1.5597.3.3.0.36
trap to be sent when NTP is synchronised
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapPtpPortDisconnected
1.3.6.1.4.1.5597.3.3.0.37
trap to be sent when PTP network port got disconnected
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapPtpPortConnected
1.3.6.1.4.1.5597.3.3.0.38
trap to be sent when PTP network port got connected
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapPtpStateChanged
1.3.6.1.4.1.5597.3.3.0.39
trap to be sent when PTP state changed (e.g. from 'passive' to 'master')
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapPtpError
1.3.6.1.4.1.5597.3.3.0.40
trap to be sent when PTP raised an error
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapNormalOperation
1.3.6.1.4.1.5597.3.3.0.77
trap to be sent when the system returned to a healthy state
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapHeartbeat
1.3.6.1.4.1.5597.3.3.0.88
trap to be sent periodically to indicate that time server is still alive
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapTestNotification
1.3.6.1.4.1.5597.3.3.0.99
trap to be sent when a test notification has been requested
Status: current
Access: read-write
NOTIFICATION-TYPE
mbgLtTrapMessage
1.3.6.1.4.1.5597.3.3.0.100
used as a payload object for all traps, holds a clear text event message
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtCfg
1.3.6.1.4.1.5597.3.4
OBJECT IDENTIFIER
mbgLtCfgNetwork
1.3.6.1.4.1.5597.3.4.1
OBJECT IDENTIFIER
mbgLtCfgHostname
1.3.6.1.4.1.5597.3.4.1.1
The hostname configured for this LANTIME
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgDomainname
1.3.6.1.4.1.5597.3.4.1.2
The domainname configured for this LANTIME
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNameserver1
1.3.6.1.4.1.5597.3.4.1.3
The first nameserver used by this LANTIME
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNameserver2
1.3.6.1.4.1.5597.3.4.1.4
The second nameserver used this LANTIME
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgSyslogserver1
1.3.6.1.4.1.5597.3.4.1.5
The first syslog server we are sending log entries to
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgSyslogserver2
1.3.6.1.4.1.5597.3.4.1.6
The second syslog server we are sending log entries to
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgTelnetAccess
1.3.6.1.4.1.5597.3.4.1.7
Is telnet administration enabled
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgFTPAccess
1.3.6.1.4.1.5597.3.4.1.8
Is FTP administration enabled
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgHTTPAccess
1.3.6.1.4.1.5597.3.4.1.9
Is web based administration enabled
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgHTTPSAccess
1.3.6.1.4.1.5597.3.4.1.10
Is secure web based administration enabled
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgSNMPAccess
1.3.6.1.4.1.5597.3.4.1.11
Is SNMP administration enabled
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgSambaAccess
1.3.6.1.4.1.5597.3.4.1.12
Is Samba administration enabled
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgIPv6Access
1.3.6.1.4.1.5597.3.4.1.13
Is IPv6 support enabled
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgSSHAccess
1.3.6.1.4.1.5597.3.4.1.14
Is SSH administration enabled
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTP
1.3.6.1.4.1.5597.3.4.2
OBJECT IDENTIFIER
mbgLtCfgNTPServer1
1.3.6.1.4.1.5597.3.4.2.1
OBJECT IDENTIFIER
mbgLtCfgNTPServer2
1.3.6.1.4.1.5597.3.4.2.2
OBJECT IDENTIFIER
mbgLtCfgNTPServer3
1.3.6.1.4.1.5597.3.4.2.3
OBJECT IDENTIFIER
mbgLtCfgNTPServer4
1.3.6.1.4.1.5597.3.4.2.4
OBJECT IDENTIFIER
mbgLtCfgNTPServer5
1.3.6.1.4.1.5597.3.4.2.5
OBJECT IDENTIFIER
mbgLtCfgNTPServer6
1.3.6.1.4.1.5597.3.4.2.6
OBJECT IDENTIFIER
mbgLtCfgNTPServer7
1.3.6.1.4.1.5597.3.4.2.7
OBJECT IDENTIFIER
mbgLtCfgNTPServer1IP
1.3.6.1.4.1.5597.3.4.2.1.1
IP address for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNTPServer1Key
1.3.6.1.4.1.5597.3.4.2.1.2
Key for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgNTPServer1Autokey
1.3.6.1.4.1.5597.3.4.2.1.3
Is autokey enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer1Prefer
1.3.6.1.4.1.5597.3.4.2.1.4
Is the preferred flag enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer2IP
1.3.6.1.4.1.5597.3.4.2.2.1
IP address for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNTPServer2Key
1.3.6.1.4.1.5597.3.4.2.2.2
Key for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgNTPServer2Autokey
1.3.6.1.4.1.5597.3.4.2.2.3
Is autokey enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer2Prefer
1.3.6.1.4.1.5597.3.4.2.2.4
Is the preferred flag enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer3IP
1.3.6.1.4.1.5597.3.4.2.3.1
IP address for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNTPServer3Key
1.3.6.1.4.1.5597.3.4.2.3.2
Key for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgNTPServer3Autokey
1.3.6.1.4.1.5597.3.4.2.3.3
Is autokey enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer3Prefer
1.3.6.1.4.1.5597.3.4.2.3.4
Is the preferred flag enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer4IP
1.3.6.1.4.1.5597.3.4.2.4.1
IP address for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNTPServer4Key
1.3.6.1.4.1.5597.3.4.2.4.2
Key for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgNTPServer4Autokey
1.3.6.1.4.1.5597.3.4.2.4.3
Is autokey enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer4Prefer
1.3.6.1.4.1.5597.3.4.2.4.4
Is the preferred flag enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer5IP
1.3.6.1.4.1.5597.3.4.2.5.1
IP address for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNTPServer5Key
1.3.6.1.4.1.5597.3.4.2.5.2
Key for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgNTPServer5Autokey
1.3.6.1.4.1.5597.3.4.2.5.3
Is autokey enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer5Prefer
1.3.6.1.4.1.5597.3.4.2.5.4
Is the preferred flag enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer6IP
1.3.6.1.4.1.5597.3.4.2.6.1
IP address for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNTPServer6Key
1.3.6.1.4.1.5597.3.4.2.6.2
Key for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgNTPServer6Autokey
1.3.6.1.4.1.5597.3.4.2.6.3
Is autokey enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer6Prefer
1.3.6.1.4.1.5597.3.4.2.6.4
Is the preferred flag enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer7IP
1.3.6.1.4.1.5597.3.4.2.7.1
IP address for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNTPServer7Key
1.3.6.1.4.1.5597.3.4.2.7.2
Key for external NTP server
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgNTPServer7Autokey
1.3.6.1.4.1.5597.3.4.2.7.3
Is autokey enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPServer7Prefer
1.3.6.1.4.1.5597.3.4.2.7.4
Is the preferred flag enabled for the external NTP server
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPStratumLocalClock
1.3.6.1.4.1.5597.3.4.2.8
The stratum value assigned to the local clock of the timeserver
Status: current
Access: read-write
OBJECT-TYPE
Integer32
0..15
mbgLtCfgNTPTrustedKey
1.3.6.1.4.1.5597.3.4.2.9
The key used for the internal refclock of the timeserver
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgNTPBroadcastIP
1.3.6.1.4.1.5597.3.4.2.10
NTP broadcast IP address
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNTPBroadcastKey
1.3.6.1.4.1.5597.3.4.2.11
Key used for NTP broadcasts
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgNTPBroadcastAutokey
1.3.6.1.4.1.5597.3.4.2.12
Is autokey generation used for NTP broadcasts
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPAutokeyFeature
1.3.6.1.4.1.5597.3.4.2.13
Is the NTP autokey feature enabled
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgNTPAtomPPS
1.3.6.1.4.1.5597.3.4.2.14
Is the NTP atom pps feature enabled
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEMail
1.3.6.1.4.1.5597.3.4.3
OBJECT IDENTIFIER
mbgLtCfgEMailTo
1.3.6.1.4.1.5597.3.4.3.1
EMail address to send alerts etc. to (receiving address)
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEMailFrom
1.3.6.1.4.1.5597.3.4.3.2
EMail address to send alerts etc. from (sending address)
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEMailSmarthost
1.3.6.1.4.1.5597.3.4.3.3
SMTP smarthost used to send mail
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgSNMP
1.3.6.1.4.1.5597.3.4.4
OBJECT IDENTIFIER
mbgLtCfgSNMPTrapReceiver1
1.3.6.1.4.1.5597.3.4.4.1
First SNMP trap receiver host
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgSNMPTrapReceiver2
1.3.6.1.4.1.5597.3.4.4.2
Second SNMP trap receiver host
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgSNMPTrapRec1Community
1.3.6.1.4.1.5597.3.4.4.3
First SNMP trap receiver community
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgSNMPTrapRec2Community
1.3.6.1.4.1.5597.3.4.4.4
Second SNMP trap receiver community
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgSNMPReadOnlyCommunity
1.3.6.1.4.1.5597.3.4.4.5
SNMP community string for read-only access
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgSNMPReadWriteCommunity
1.3.6.1.4.1.5597.3.4.4.6
SNMP community string for read-write access
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgSNMPContact
1.3.6.1.4.1.5597.3.4.4.7
SNMP contact string for Lantime
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgSNMPLocation
1.3.6.1.4.1.5597.3.4.4.8
SNMP location string for Lantime
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgWinpopup
1.3.6.1.4.1.5597.3.4.5
OBJECT IDENTIFIER
mbgLtCfgWMailAddress1
1.3.6.1.4.1.5597.3.4.5.1
First windows popup alert receiver
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgWMailAddress2
1.3.6.1.4.1.5597.3.4.5.2
Second windows popup alert receiver
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgWalldisplay
1.3.6.1.4.1.5597.3.4.6
OBJECT IDENTIFIER
mbgLtCfgVP100Display1IP
1.3.6.1.4.1.5597.3.4.6.1
IP address of first VP100 wall display
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgVP100Display1SN
1.3.6.1.4.1.5597.3.4.6.2
Serial number of first VP100 wall display
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgVP100Display2IP
1.3.6.1.4.1.5597.3.4.6.3
IP address of second VP100 wall display
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgVP100Display2SN
1.3.6.1.4.1.5597.3.4.6.4
Serial number of second VP100 wall display
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNotify
1.3.6.1.4.1.5597.3.4.7
OBJECT IDENTIFIER
mbgLtCfgNotifyNTPNotSync
1.3.6.1.4.1.5597.3.4.7.1
Which alerts are sent in case of a NTP_not_sync event
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNotifyNTPStopped
1.3.6.1.4.1.5597.3.4.7.2
Which alerts are sent in case of a NTP_stopped event
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNotifyServerBoot
1.3.6.1.4.1.5597.3.4.7.3
Which alerts are sent in case of a server_boot event
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNotifyRefclkNoResponse
1.3.6.1.4.1.5597.3.4.7.4
Which alerts are sent in case of a refclock_not_responding event
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNotifyRefclockNotSync
1.3.6.1.4.1.5597.3.4.7.5
Which alerts are sent in case of a refclock_not_sync event
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNotifyAntennaFaulty
1.3.6.1.4.1.5597.3.4.7.6
Which alerts are sent in case of an antenna_faulty event
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNotifyAntennaReconnect
1.3.6.1.4.1.5597.3.4.7.7
Which alerts are sent in case of an antenna_reconnect event
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNotifyConfigChanged
1.3.6.1.4.1.5597.3.4.7.8
Which alerts are sent in case of a config_changed event
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNotifySHSTimeLimitError
1.3.6.1.4.1.5597.3.4.7.9
Which alerts are sent in case of a SHS_timelimiterror event
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgNotifyLeapSecond
1.3.6.1.4.1.5597.3.4.7.10
Which alerts are sent in case of a Leap_Second_Announced event
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernet
1.3.6.1.4.1.5597.3.4.8
OBJECT IDENTIFIER
mbgLtCfgEthernetIf0
1.3.6.1.4.1.5597.3.4.8.0
OBJECT IDENTIFIER
mbgLtCfgEthernetIf1
1.3.6.1.4.1.5597.3.4.8.1
OBJECT IDENTIFIER
mbgLtCfgEthernetIf2
1.3.6.1.4.1.5597.3.4.8.2
OBJECT IDENTIFIER
mbgLtCfgEthernetIf3
1.3.6.1.4.1.5597.3.4.8.3
OBJECT IDENTIFIER
mbgLtCfgEthernetIf4
1.3.6.1.4.1.5597.3.4.8.4
OBJECT IDENTIFIER
mbgLtCfgEthernetIf5
1.3.6.1.4.1.5597.3.4.8.5
OBJECT IDENTIFIER
mbgLtCfgEthernetIf6
1.3.6.1.4.1.5597.3.4.8.6
OBJECT IDENTIFIER
mbgLtCfgEthernetIf7
1.3.6.1.4.1.5597.3.4.8.7
OBJECT IDENTIFIER
mbgLtCfgEthernetIf8
1.3.6.1.4.1.5597.3.4.8.8
OBJECT IDENTIFIER
mbgLtCfgEthernetIf9
1.3.6.1.4.1.5597.3.4.8.9
OBJECT IDENTIFIER
mbgLtCfgEthernetIf0IPv4IP
1.3.6.1.4.1.5597.3.4.8.0.1
The IPv4 address of the first ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf0IPv4Netmask
1.3.6.1.4.1.5597.3.4.8.0.2
The IPv4 netmask of the first ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf0IPv4Gateway
1.3.6.1.4.1.5597.3.4.8.0.3
The IPv4 gateway address of the first ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf0DHCPClient
1.3.6.1.4.1.5597.3.4.8.0.4
Is DHCP used to get IP parameters for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf0IPv6IP1
1.3.6.1.4.1.5597.3.4.8.0.5
The first IPv6 address of the first ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf0IPv6IP2
1.3.6.1.4.1.5597.3.4.8.0.6
The second IPv6 address of the first ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf0IPv6IP3
1.3.6.1.4.1.5597.3.4.8.0.7
The third IPv6 address of the first ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf0IPv6Autoconf
1.3.6.1.4.1.5597.3.4.8.0.8
Is IPv6 Autoconf used for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf0NetLinkMode
1.3.6.1.4.1.5597.3.4.8.0.9
Link mode for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
autosensing(0), link10half(1), link10full(2), link100half(3), link100full(4)
mbgLtCfgEthernetIf1IPv4IP
1.3.6.1.4.1.5597.3.4.8.1.1
The IPv4 address of the second ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf1IPv4Netmask
1.3.6.1.4.1.5597.3.4.8.1.2
The IPv4 netmask of the second ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf1IPv4Gateway
1.3.6.1.4.1.5597.3.4.8.1.3
The IPv4 gateway address of the second ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf1DHCPClient
1.3.6.1.4.1.5597.3.4.8.1.4
Is DHCP used to get IP parameters for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf1IPv6IP1
1.3.6.1.4.1.5597.3.4.8.1.5
The first IPv6 address of the second ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf1IPv6IP2
1.3.6.1.4.1.5597.3.4.8.1.6
The second IPv6 address of the second ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf1IPv6IP3
1.3.6.1.4.1.5597.3.4.8.1.7
The third IPv6 address of the second ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf1IPv6Autoconf
1.3.6.1.4.1.5597.3.4.8.1.8
Is IPv6 Autoconf used for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf1NetLinkMode
1.3.6.1.4.1.5597.3.4.8.1.9
Link mode for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
autosensing(0), link10half(1), link10full(2), link100half(3), link100full(4)
mbgLtCfgEthernetIf2IPv4IP
1.3.6.1.4.1.5597.3.4.8.2.1
The IPv4 address of the third ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf2IPv4Netmask
1.3.6.1.4.1.5597.3.4.8.2.2
The IPv4 netmask of the third ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf2IPv4Gateway
1.3.6.1.4.1.5597.3.4.8.2.3
The IPv4 gateway address of the third ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf2DHCPClient
1.3.6.1.4.1.5597.3.4.8.2.4
Is DHCP used to get IP parameters for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf2IPv6IP1
1.3.6.1.4.1.5597.3.4.8.2.5
The first IPv6 address of the third ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf2IPv6IP2
1.3.6.1.4.1.5597.3.4.8.2.6
The second IPv6 address of the third ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf2IPv6IP3
1.3.6.1.4.1.5597.3.4.8.2.7
The third IPv6 address of the third ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf2IPv6Autoconf
1.3.6.1.4.1.5597.3.4.8.2.8
Is IPv6 Autoconf used for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf2NetLinkMode
1.3.6.1.4.1.5597.3.4.8.2.9
Link mode for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
autosensing(0), link10half(1), link10full(2), link100half(3), link100full(4)
mbgLtCfgEthernetIf3IPv4IP
1.3.6.1.4.1.5597.3.4.8.3.1
The IPv4 address of the fourth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf3IPv4Netmask
1.3.6.1.4.1.5597.3.4.8.3.2
The IPv4 netmask of the fourth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf3IPv4Gateway
1.3.6.1.4.1.5597.3.4.8.3.3
The IPv4 gateway address of the fourth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf3DHCPClient
1.3.6.1.4.1.5597.3.4.8.3.4
Is DHCP used to get IP parameters for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf3IPv6IP1
1.3.6.1.4.1.5597.3.4.8.3.5
The first IPv6 address of the fourth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf3IPv6IP2
1.3.6.1.4.1.5597.3.4.8.3.6
The second IPv6 address of the fourth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf3IPv6IP3
1.3.6.1.4.1.5597.3.4.8.3.7
The third IPv6 address of the fourth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf3IPv6Autoconf
1.3.6.1.4.1.5597.3.4.8.3.8
Is IPv6 Autoconf used for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf3NetLinkMode
1.3.6.1.4.1.5597.3.4.8.3.9
Link mode for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
autosensing(0), link10half(1), link10full(2), link100half(3), link100full(4)
mbgLtCfgEthernetIf4IPv4IP
1.3.6.1.4.1.5597.3.4.8.4.1
The IPv4 address of the fifth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf4IPv4Netmask
1.3.6.1.4.1.5597.3.4.8.4.2
The IPv4 netmask of the fifth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf4IPv4Gateway
1.3.6.1.4.1.5597.3.4.8.4.3
The IPv4 gateway address of the fifth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf4DHCPClient
1.3.6.1.4.1.5597.3.4.8.4.4
Is DHCP used to get IP parameters for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf4IPv6IP1
1.3.6.1.4.1.5597.3.4.8.4.5
The first IPv6 address of the fifth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf4IPv6IP2
1.3.6.1.4.1.5597.3.4.8.4.6
The second IPv6 address of the fifth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf4IPv6IP3
1.3.6.1.4.1.5597.3.4.8.4.7
The third IPv6 address of the fifth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf4IPv6Autoconf
1.3.6.1.4.1.5597.3.4.8.4.8
Is IPv6 Autoconf used for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf4NetLinkMode
1.3.6.1.4.1.5597.3.4.8.4.9
Link mode for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
autosensing(0), link10half(1), link10full(2), link100half(3), link100full(4)
mbgLtCfgEthernetIf5IPv4IP
1.3.6.1.4.1.5597.3.4.8.5.1
The IPv4 address of the sixth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf5IPv4Netmask
1.3.6.1.4.1.5597.3.4.8.5.2
The IPv4 netmask of the sixth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf5IPv4Gateway
1.3.6.1.4.1.5597.3.4.8.5.3
The IPv4 gateway address of the sixth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf5DHCPClient
1.3.6.1.4.1.5597.3.4.8.5.4
Is DHCP used to get IP parameters for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf5IPv6IP1
1.3.6.1.4.1.5597.3.4.8.5.5
The first IPv6 address of the sixth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf5IPv6IP2
1.3.6.1.4.1.5597.3.4.8.5.6
The second IPv6 address of the sixth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf5IPv6IP3
1.3.6.1.4.1.5597.3.4.8.5.7
The third IPv6 address of the sixth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf5IPv6Autoconf
1.3.6.1.4.1.5597.3.4.8.5.8
Is IPv6 Autoconf used for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf5NetLinkMode
1.3.6.1.4.1.5597.3.4.8.5.9
Link mode for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
autosensing(0), link10half(1), link10full(2), link100half(3), link100full(4)
mbgLtCfgEthernetIf6IPv4IP
1.3.6.1.4.1.5597.3.4.8.6.1
The IPv4 address of the seventh ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf6IPv4Netmask
1.3.6.1.4.1.5597.3.4.8.6.2
The IPv4 netmask of the seventh ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf6IPv4Gateway
1.3.6.1.4.1.5597.3.4.8.6.3
The IPv4 gateway address of the seventh ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf6DHCPClient
1.3.6.1.4.1.5597.3.4.8.6.4
Is DHCP used to get IP parameters for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf6IPv6IP1
1.3.6.1.4.1.5597.3.4.8.6.5
The first IPv6 address of the seventh ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf6IPv6IP2
1.3.6.1.4.1.5597.3.4.8.6.6
The second IPv6 address of the seventh ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf6IPv6IP3
1.3.6.1.4.1.5597.3.4.8.6.7
The third IPv6 address of the seventh ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf6IPv6Autoconf
1.3.6.1.4.1.5597.3.4.8.6.8
Is IPv6 Autoconf used for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf6NetLinkMode
1.3.6.1.4.1.5597.3.4.8.6.9
Link mode for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
autosensing(0), link10half(1), link10full(2), link100half(3), link100full(4)
mbgLtCfgEthernetIf7IPv4IP
1.3.6.1.4.1.5597.3.4.8.7.1
The IPv4 address of the eighth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf7IPv4Netmask
1.3.6.1.4.1.5597.3.4.8.7.2
The IPv4 netmask of the eighth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf7IPv4Gateway
1.3.6.1.4.1.5597.3.4.8.7.3
The IPv4 gateway address of the eighth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf7DHCPClient
1.3.6.1.4.1.5597.3.4.8.7.4
Is DHCP used to get IP parameters for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf7IPv6IP1
1.3.6.1.4.1.5597.3.4.8.7.5
The first IPv6 address of the eighth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf7IPv6IP2
1.3.6.1.4.1.5597.3.4.8.7.6
The second IPv6 address of the eighth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf7IPv6IP3
1.3.6.1.4.1.5597.3.4.8.7.7
The third IPv6 address of the eighth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf7IPv6Autoconf
1.3.6.1.4.1.5597.3.4.8.7.8
Is IPv6 Autoconf used for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf7NetLinkMode
1.3.6.1.4.1.5597.3.4.8.7.9
Link mode for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
autosensing(0), link10half(1), link10full(2), link100half(3), link100full(4)
mbgLtCfgEthernetIf8IPv4IP
1.3.6.1.4.1.5597.3.4.8.8.1
The IPv4 address of the nineth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf8IPv4Netmask
1.3.6.1.4.1.5597.3.4.8.8.2
The IPv4 netmask of the nineth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf8IPv4Gateway
1.3.6.1.4.1.5597.3.4.8.8.3
The IPv4 gateway address of the nineth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf8DHCPClient
1.3.6.1.4.1.5597.3.4.8.8.4
Is DHCP used to get IP parameters for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf8IPv6IP1
1.3.6.1.4.1.5597.3.4.8.8.5
The first IPv6 address of the nineth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf8IPv6IP2
1.3.6.1.4.1.5597.3.4.8.8.6
The second IPv6 address of the nineth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf8IPv6IP3
1.3.6.1.4.1.5597.3.4.8.8.7
The third IPv6 address of the nineth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf8IPv6Autoconf
1.3.6.1.4.1.5597.3.4.8.8.8
Is IPv6 Autoconf used for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf8NetLinkMode
1.3.6.1.4.1.5597.3.4.8.8.9
Link mode for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
autosensing(0), link10half(1), link10full(2), link100half(3), link100full(4)
mbgLtCfgEthernetIf9IPv4IP
1.3.6.1.4.1.5597.3.4.8.9.1
The IPv4 address of the tenth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf9IPv4Netmask
1.3.6.1.4.1.5597.3.4.8.9.2
The IPv4 netmask of the tenth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf9IPv4Gateway
1.3.6.1.4.1.5597.3.4.8.9.3
The IPv4 gateway address of the tenth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf9DHCPClient
1.3.6.1.4.1.5597.3.4.8.9.4
Is DHCP used to get IP parameters for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf9IPv6IP1
1.3.6.1.4.1.5597.3.4.8.9.5
The first IPv6 address of the tenth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf9IPv6IP2
1.3.6.1.4.1.5597.3.4.8.9.6
The second IPv6 address of the tenth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf9IPv6IP3
1.3.6.1.4.1.5597.3.4.8.9.7
The third IPv6 address of the tenth ethernet interface
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCfgEthernetIf9IPv6Autoconf
1.3.6.1.4.1.5597.3.4.8.9.8
Is IPv6 Autoconf used for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
disabled(0), enabled(1)
mbgLtCfgEthernetIf9NetLinkMode
1.3.6.1.4.1.5597.3.4.8.9.9
Link mode for this interface
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
autosensing(0), link10half(1), link10full(2), link100half(3), link100full(4)
mbgLtCfgSHS
1.3.6.1.4.1.5597.3.4.9
OBJECT IDENTIFIER
mbgLtCfgSHSCritLimit
1.3.6.1.4.1.5597.3.4.9.1
Max. number of milliseconds the two SHS references can differ before a SHS Critical Timelimit error is issued
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgSHSWarnLimit
1.3.6.1.4.1.5597.3.4.9.2
Max. number of milliseconds the two SHS references can differ before a SHS Warning Timelimit error is issued
Status: current
Access: read-write
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtCfgMRS
1.3.6.1.4.1.5597.3.4.10
OBJECT IDENTIFIER
mbgLtCfgMRSRefPriority
1.3.6.1.4.1.5597.3.4.10.1
Priority of MRS Reference Sources, as a comma-separated list
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtCmd
1.3.6.1.4.1.5597.3.5
OBJECT IDENTIFIER
mbgLtCmdExecute
1.3.6.1.4.1.5597.3.5.1
Send a command to the timeserver to be executed
Status: current
Access: read-write
OBJECT-TYPE
INTEGER
ready(0), doReboot(1), doFirmwareUpdate(2), doReloadConfig(3), doGenerateSSHKey(4), doGenerateHTTPSKey(5), doResetFactoryDefaults(6), doGenerateNewNTPAutokeyCert(7), doSendTestNotification(8), doResetSHSTimeLimitError(9)
mbgLtCmdSetRefTime
1.3.6.1.4.1.5597.3.5.2
Set the time of the reference clock and the LANTIME itself
Status: current
Access: read-write
OBJECT-TYPE
DisplayString
mbgLtPtp
1.3.6.1.4.1.5597.3.10
OBJECT IDENTIFIER
mbgLtPtpMode
1.3.6.1.4.1.5597.3.10.1
Display current PTPv2 modus as string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtPtpModeVal
1.3.6.1.4.1.5597.3.10.2
Display current PTPv2 modus as integer
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
stopped(0), master(1), slave(2), ordinary(3)
mbgLtPtpPortState
1.3.6.1.4.1.5597.3.10.3
Current PTPv2 port state as string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtPtpPortStateVal
1.3.6.1.4.1.5597.3.10.4
Current PTPv2 port state as integer
Status: current
Access: read-only
OBJECT-TYPE
INTEGER
uncalibrated(0), initializing(1), listening(2), master(3), slave(4), unicastmaster(5), unicastslave(6)
mbgLtPtpOffsetFromGM
1.3.6.1.4.1.5597.3.10.5
Current PTPv2 offset from grandmaster as string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtPtpOffsetFromGMVal
1.3.6.1.4.1.5597.3.10.6
Current PTPv2 offset from grandmaster in nanoseconds
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtPtpDelay
1.3.6.1.4.1.5597.3.10.7
shows the current network delay in nanoseconds as string
Status: current
Access: read-only
OBJECT-TYPE
DisplayString
mbgLtPtpDelayVal
1.3.6.1.4.1.5597.3.10.8
shows the current network delay in nanoseconds
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtFdm
1.3.6.1.4.1.5597.3.11
OBJECT IDENTIFIER
mbgLtFdmPlFreq
1.3.6.1.4.1.5597.3.11.1
shows the current powerline frequency in mHz as an Integer32 value
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtFdmFreqDev
1.3.6.1.4.1.5597.3.11.2
shows the current frequency deviation in mHz as an Integer32 value
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtFdmNomFreq
1.3.6.1.4.1.5597.3.11.3
shows the nominal frequency in mHz as an Integer32 value
Status: current
Access: read-only
OBJECT-TYPE
Integer32
-2147483648..2147483647
mbgLtConformance
1.3.6.1.4.1.5597.3.90
OBJECT IDENTIFIER
mbgLtCompliances
1.3.6.1.4.1.5597.3.90.1
OBJECT IDENTIFIER
mbgLtGroups
1.3.6.1.4.1.5597.3.90.2
OBJECT IDENTIFIER
mbgLtCompliance
1.3.6.1.4.1.5597.3.90.1.1
The compliance statement for SNMP entities which implement version 2 of the LANTIME MIB
Status: current
Access: read-only
MODULE-COMPLIANCE
mbgLtObjectsGroup
1.3.6.1.4.1.5597.3.90.2.1
The collection of objects for the LANTIME MIB
Status: current
Access: read-only
OBJECT-GROUP
mbgLtTrapsGroup
1.3.6.1.4.1.5597.3.90.2.2
The collection of traps for the LANTIME MIB
Status: current
Access: read-only
NOTIFICATION-GROUP