LaserJet6P-MIB

File: LaserJet6P-MIB.mib (185341 bytes)

Imported modules

RFC1155-SMI

Imported symbols

OBJECT-TYPE enterprises

Defined Types

DisplayString  
OCTET STRING    

Defined Values

hp 1.3.6.1.4.1.11
OBJECT IDENTIFIER    

nm 1.3.6.1.4.1.11.2
OBJECT IDENTIFIER    

hpsystem 1.3.6.1.4.1.11.2.3
OBJECT IDENTIFIER    

net-peripheral 1.3.6.1.4.1.11.2.3.9
OBJECT IDENTIFIER    

netdm 1.3.6.1.4.1.11.2.3.9.4
OBJECT IDENTIFIER    

dm 1.3.6.1.4.1.11.2.3.9.4.2
OBJECT IDENTIFIER    

device 1.3.6.1.4.1.11.2.3.9.4.2.1
OBJECT IDENTIFIER    

system 1.3.6.1.4.1.11.2.3.9.4.2.1.1
OBJECT IDENTIFIER    

settings-system 1.3.6.1.4.1.11.2.3.9.4.2.1.1.1
OBJECT IDENTIFIER    

status-system 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2
OBJECT IDENTIFIER    

id 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3
OBJECT IDENTIFIER    

interface 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4
OBJECT IDENTIFIER    

simm 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1
OBJECT IDENTIFIER    

simm1 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1
OBJECT IDENTIFIER    

simm2 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2
OBJECT IDENTIFIER    

simm3 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3
OBJECT IDENTIFIER    

test 1.3.6.1.4.1.11.2.3.9.4.2.1.1.5
OBJECT IDENTIFIER    

job 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6
OBJECT IDENTIFIER    

settings-job 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1
OBJECT IDENTIFIER    

active-print-jobs 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.2
OBJECT IDENTIFIER    

job-being-parsed 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.2.1
OBJECT IDENTIFIER    

job-info 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5
OBJECT IDENTIFIER    

job-info-attribute 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23
OBJECT IDENTIFIER    

source-subsystem 1.3.6.1.4.1.11.2.3.9.4.2.1.2
OBJECT IDENTIFIER    

io 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1
OBJECT IDENTIFIER    

settings-io 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1
OBJECT IDENTIFIER    

processing-subsystem 1.3.6.1.4.1.11.2.3.9.4.2.1.3
OBJECT IDENTIFIER    

pdl 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3
OBJECT IDENTIFIER    

settings-pdl 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1
OBJECT IDENTIFIER    

status-pdl 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.2
OBJECT IDENTIFIER    

pdl-pcl 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3
OBJECT IDENTIFIER    

pdl-postscript 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4
OBJECT IDENTIFIER    

pjl 1.3.6.1.4.1.11.2.3.9.4.2.1.3.5
OBJECT IDENTIFIER    

destination-subsystem 1.3.6.1.4.1.11.2.3.9.4.2.1.4
OBJECT IDENTIFIER    


settings-prt-eng 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1
OBJECT IDENTIFIER    

intray 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3
OBJECT IDENTIFIER    

settings-intray 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.1
OBJECT IDENTIFIER    

imaging 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.6
OBJECT IDENTIFIER    

tables 1.3.6.1.4.1.11.2.3.9.4.2.1.7
OBJECT IDENTIFIER    

channel-table 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2
OBJECT IDENTIFIER    

channel-entry 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1
OBJECT IDENTIFIER    

hrm 1.3.6.1.4.1.11.2.3.9.4.2.3
OBJECT IDENTIFIER    

hrStorage 1.3.6.1.4.1.11.2.3.9.4.2.3.2
OBJECT IDENTIFIER    

hrStorageTable 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3
OBJECT IDENTIFIER    

hrStorageEntry 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1
OBJECT IDENTIFIER    

hrDevice 1.3.6.1.4.1.11.2.3.9.4.2.3.3
OBJECT IDENTIFIER    

hrDeviceTable 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2
OBJECT IDENTIFIER    

hrDeviceEntry 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1
OBJECT IDENTIFIER    

hrPrinterTable 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5
OBJECT IDENTIFIER    

hrPrinterEntry 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5.1
OBJECT IDENTIFIER    

printmib 1.3.6.1.4.1.11.2.3.9.4.2.2
OBJECT IDENTIFIER    

prtGeneral 1.3.6.1.4.1.11.2.3.9.4.2.2.5
OBJECT IDENTIFIER    

prtGeneralTable 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1
OBJECT IDENTIFIER    

prtGeneralEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1
OBJECT IDENTIFIER    

prtCover 1.3.6.1.4.1.11.2.3.9.4.2.2.6
OBJECT IDENTIFIER    

prtCoverTable 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1
OBJECT IDENTIFIER    

prtCoverEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1.1
OBJECT IDENTIFIER    

prtLocalization 1.3.6.1.4.1.11.2.3.9.4.2.2.7
OBJECT IDENTIFIER    

prtLocalizationTable 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1
OBJECT IDENTIFIER    

prtLocalizationEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1
OBJECT IDENTIFIER    

prtStorageRefTable 1.3.6.1.4.1.11.2.3.9.4.2.2.5.2
OBJECT IDENTIFIER    

prtStorageRefEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.5.2.1
OBJECT IDENTIFIER    

prtDeviceRefTable 1.3.6.1.4.1.11.2.3.9.4.2.2.5.3
OBJECT IDENTIFIER    

prtDeviceRefEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.5.3.1
OBJECT IDENTIFIER    

prtInput 1.3.6.1.4.1.11.2.3.9.4.2.2.8
OBJECT IDENTIFIER    

prtInputTable 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2
OBJECT IDENTIFIER    

prtInputEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1
OBJECT IDENTIFIER    

prtOutput 1.3.6.1.4.1.11.2.3.9.4.2.2.9
OBJECT IDENTIFIER    

prtOutputTable 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2
OBJECT IDENTIFIER    

prtOutputEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1
OBJECT IDENTIFIER    

prtMarker 1.3.6.1.4.1.11.2.3.9.4.2.2.10
OBJECT IDENTIFIER    

prtMarkerTable 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2
OBJECT IDENTIFIER    

prtMarkerEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1
OBJECT IDENTIFIER    

prtMarkerSupplies 1.3.6.1.4.1.11.2.3.9.4.2.2.11
OBJECT IDENTIFIER    

prtMarkerSuppliesTable 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1
OBJECT IDENTIFIER    

prtMarkerSuppliesEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1
OBJECT IDENTIFIER    

prtMediaPath 1.3.6.1.4.1.11.2.3.9.4.2.2.13
OBJECT IDENTIFIER    

prtMediaPathTable 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4
OBJECT IDENTIFIER    

prtMediaPathEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1
OBJECT IDENTIFIER    

prtChannel 1.3.6.1.4.1.11.2.3.9.4.2.2.14
OBJECT IDENTIFIER    

prtChannelTable 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1
OBJECT IDENTIFIER    

prtChannelEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1
OBJECT IDENTIFIER    

prtInterpreter 1.3.6.1.4.1.11.2.3.9.4.2.2.15
OBJECT IDENTIFIER    

prtInterpreterTable 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1
OBJECT IDENTIFIER    

prtInterpreterEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1
OBJECT IDENTIFIER    

prtConsoleDisplayBuffer 1.3.6.1.4.1.11.2.3.9.4.2.2.16
OBJECT IDENTIFIER    

prtConsoleDisplayBufferTable 1.3.6.1.4.1.11.2.3.9.4.2.2.16.5
OBJECT IDENTIFIER    

prtConsoleDisplayBufferEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.16.5.1
OBJECT IDENTIFIER    

prtConsoleLights 1.3.6.1.4.1.11.2.3.9.4.2.2.17
OBJECT IDENTIFIER    

prtConsoleLightTable 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6
OBJECT IDENTIFIER    

prtConsoleLightEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1
OBJECT IDENTIFIER    

prtAlert 1.3.6.1.4.1.11.2.3.9.4.2.2.18
OBJECT IDENTIFIER    

prtAlertTable 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1
OBJECT IDENTIFIER    

prtAlertEntry 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1
OBJECT IDENTIFIER    

energy-star 1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.1
Returns or changes the Energy Star sleep value. If the value is greater than zero, then the device will go into energy saving sleep mode after the print engine has been idle for the number of seconds specified by this object. A value of zero means Energy Star is disabled and the device will not go to sleep based on print engine idle time. The value must be non-negative. Additional information: LaserJet 6P will always be in sleep mode when not processing data. This object will always return a value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

sleep-mode 1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.2
Returns eTrue if the device is in energy saving sleep mode, otherwise returns eFalse. Setting SLEEP-MODE to eFalse causes the device to wake up, if it is in sleep mode. Setting SLEEP-MODE to eTrue causes the device to go into sleep mode. Additional information: LaserJet 6P will always be in sleep mode when not processing a print job.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER eFalse(1), eTrue(2)  

on-off-line 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.5
To bring the PDL processing sub-system on or off line. If the device is a printer, then the printer does not process print job data when the printer is off line. PML communication persists. Additional information: LaserJet 6P will only be in the offline
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER eOnline(1), eOffline(2), eOfflineAtEndOfJob(3)  

continue 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.6
A device can support a class of errors called continuable errors. When a continuable error is encountered, the device requires a continue event to occur before the device will continue operation. One continue event is setting the CONTINUE object to eInitiateAction. Devices can support other continue events, like auto-continue. A continue event causes the continuable error to be acknowledged, thus allowing the device to continue. Each device needs to list the continuable errors. If the device doesn't currently have an unacknowledged continuable error, the response will contain . Additional information: If LaserJet 6P doesn't currently have an unacknowledged continuable error, the response will contain status. The following is a list of continuable errors in LaserJet 6P: Manually feed yy Tray X Load yy 20 Insufficient Memory, Press Go Key 21 Page Too Complex, Press Go Key 22 Parallel IO Error, Press Go Key 41.x Printer Error, Press Go Key 55 Printer Error, Press Go Key 68 NVRAM Full, Settings Not Saved 68 NVRAM Error, Settings Not Saved
Status: optional Access: write-only
OBJECT-TYPE    
  INTEGER eInitiateAction(1)  

auto-continue 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7
Indicates if the device will automatically continue after encountering a continuable error. If AUTO- CONTINUE is set to eOn, the device will automatically generate continue event to acknowledge continuable errors. If AUTO-CONTINUE is set to eOff, then some other continue event will have to acknowledge the continuable error. Additional information: If the printer is not idle, the new value may not take effect until a job boundary is reached. If a get is done on this object before the job boundary is reached, the value last set will be returned. If this is eOn the device for ten seconds. After ten seconds the printer automatically returns to the online state. If this is eOff then the device displays an error message and goes offline and remains offline until the operator presses the GO key.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eOff(1), eOn(2)  

model-name 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.2
Identifies the device model name (e.g. ''DeskJet 1200C''). The string is as specific as possible. Capitalization and spacing should match family naming conventions. Products should note in POS if the model name on the HP corporate price list changes but the device reports the previous device name. If the model name changes based on the installed options, the POS should indicate if only the base model name is returned, or if the device senses the installed options and returns the correct model name. If possible, encode the model name in a symbol set (like Roman-8) that matches the ASCII character set and limit the characters used to ASCII characters. Additional information: The value of this object does not change based on the installed options. Since the value of this object is frequently used in displaying a list of printers, it is kept relatively short in case systems have limited width for their display area.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

serial-number 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.3
Identifies the serial number for the device. If the SERIAL-NUMBER object is set by the user, then setting the object does not need to be protected. If the SERIAL-NUMBER object is set at the factory, then the SERVICE-PASSWORD object must be set correctly before the SERIAL-NUMBER object is writable. If this is a writable object, the POS should indicate the maximum supported string length. If possible, encode the serial number in a symbol set (like Roman-8) that matches the ASCII character set and limit the characters used to ASCII characters. Additional information: The format of the LaserJet 6P serial number is: axxyyyzzzzz where: a = S (always) xx = 46 (the entity #) yyy = 0..9 & A..Z (the product code specific to LaserJet 6P, probably 01L) zzzzz = 0..9 & A..Z omitting I,O,U (sequentially assigned alpha/num base 33 numbers) So it will typically look like S4601LXXXXX This value IS AFFECTED BY NVRAM resets, it is set to the default value of S4601LXXXXX, when a NVRAM init is done.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

device-name 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.10
User defined device name. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as possible and will return the . Additional information: The maximum supported string length is 32 characters. If the user entered string is too long, the device will store the first 32 characters and will return the status.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString  

device-location 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.11
User defined device location. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as possible and will return the . Additional information: The maximum supported string length is 16 characters. If the user entered string is too long, the device will store the first 16 characters and will return the status.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString  

asset-number 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.12
User defined asset number. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as possible and will return the . Additional information: The maximum supported string length is 8 characters. If the user entered string is too long, the device will store the first 8 characters and will return the status.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString  

simm1-type 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.4
Returns an indication of the type of option installed in SIMM slot 1. eEmpty means the device did not detect any option installed in the interface slot. eUnknown means the device doesn't recognize the installed option. eUnSupported means the device recognizes the installed option, but does not support the option. eReadOnlyMemory means the installed option contains ROM Ics. eVolatileRandomAccessMemory means the installed option contains RAM ICs that loose data when the power is turned off. eNonVolatileRandomAccessMemory means that the installed option contains RAM ICs that do not loose data when the power is turned off. eFlashMemory means that the installed option contains a type of non-volatile RAM that needs to be erased before it can be written. eDiskDrive means the installed option contains a disk drive. eRamRom means the installed option contains both volatile random access memory and read only memory. eInputPHD means the installed option is an input paper handling device. eOutputPHD means the installed option is an output paper handling device. eIOCard means the installed option is an I/O card. Additional information: eRamRom is used to denote LaserJet 6P's combo simm.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eRamRom(9)  

simm1-capacity 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.5
Returns an indication of the capacity of the SIMM installed in SIMM slot 1. The capacity is dependent on the type of option, as indicated by the SIMM1-TYPE object. This object has no meaning if the installed option type is eUnknown or eReadOnlyMemory. This object contains the size, in bytes, if the installed option type is eVolatileRandomAccessMemory, eNonVolatileRandomAccessMemory, eFlashMemory, or eDiskDrive. If the type of the installed option is eRamRom, this object contains the size, in bytes, of the random access memory. If the type of the installed option is eInputPHD, the capacity indicates the number of input trays supported by the installed option. If the type of the installed option is eOutputPHD, the capacity indicates the number of output bins supported by the installed option. If the type of the installed option is eIOCard, the capacity indicates the number of logical I/O ports supported by the I/O card. Additional information: Returns an indication of the capacity of the installed option in bytes. This object is not supported unless the SIMM1-TYPE type is eVolatileRandomAccessMemory or eRamRom. For eRamRom only the size of the Ram portion of the SIMM is returned.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

simm2-type 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.4
Returns an indication of the type of option installed in SIMM slot 2. See SIMM1-TYPE for a description. Additional information: eRamRom is used to denote LaserJet 6P's combo simm.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eRamRom(9)  

simm2-capacity 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.5
Returns an indication of the capacity of the SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed option in bytes. This object is not supported unless the SIMM2-TYPE type is eVolatileRandomAccessMemory or eRamRom. For eRamRom only the size of the Ram portion of the SIMM is returned.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

simm3-type 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.4
Returns an indication of the type of option installed in SIMM slot 3. See SIMM1-TYPE for a description.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eRamRom(9)  

simm3-capacity 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.5
Returns an indication of the capacity of the SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed option in bytes. This object is not supported unless the SIMM3-TYPE type is eVolatileRandomAccessMemory or eRamRom. For eRamRom only the size of the Ram portion of the simm is returned.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

self-test 1.3.6.1.4.1.11.2.3.9.4.2.1.1.5.1
Writing this object allows a device self test to be started. Reading this object provides an indication what self-test is currently executing, if any. Actual self-test operation is device specific. A self test may not be allowed at any arbitrary time. If the device supports the requested self test, but can not start the execution of the self test when requested, the device will respond with . If a non-destructive self test is being started, the device will generate a response before the self test is completed. RECOMMENDATION: If the device is ready (i.e. the NOT- READY-PRINTER object does not contain any items, except maybe being off-line) and is idle (i.e. the NOT-IDLE object does not contain any items), this request should always succeed. This provides a mechanism for driver writers to always determine if the action will succeed or not. Additional information: The eNonDestructiveSelfTest performs limited testing on the printer and its attached paper handling devices. After the self-test is complete a configuration page is printed. The recommended way to cause a configuration page to be printed is to use the PRINT-INTERNAL-PAGE object. A continuous self test cannot be started or terminated using this OID. When the printer is idle, setting this object to eNonDestructiveSelfTest results in a status of and a value of eNonDestructiveSelfTest being returned. If the printer is not idle (whether printing an external job, printing an internal page or running self test), a status of status will be returned with a value of eNotInASelfTest. When the printer is idle, setting this object to eNonDestructiveSelfTest causes the page to be formatted and put in the printer's print queue. Before the page is completed formatting, (currently estimated at about 1 millisecond) a get on this object will return eNonDestructiveSelfTest. Attempting to set this object before the page has completed being formatted and printed will cause status to be returned with a value of eNotInASelfTest. After the page is in the queue, a get on this object will return a value of eNotInASelfTest. Setting the value to eNotInASelfTest is not supported on LaserJet 6P. Once the test has started, it will finish Printing. Likewise, if the PRINT-INTERNAL-PAGE object is set to a valid value and that page has not printed when this object is set to eNonDestructiveSelfTest, a status of status with a value of eNotInASelfTest will be returned until the internal page has printed.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eNotInASelfTest(1), eNonDestructiveSelfTest(4)  


job-info-change-id 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1.3
Returns the current value of an object in the job-info sub-tree whose value has changed. Define the object identifier for the object whose value has changed as job-info.required-field.optional-field.job-id. job-info represents the OID prefix of all objects in the job-info sub-tree. Required-field represents the OID field value that follows the job-info prefix. Since some objects in the job-info sub-tree have two OID fields between the job-info prefix and the job-id, the optional-field represents the OID field between the required-field and the job-id field, if present. Using this definition, the format for the JOB-INFO-CHANGE-ID binary value can be described as follows: Bytes 0-3 : required-field Bytes 4-7 : optional-field, or all zeros if there is no optional field Bytes 8-11: Job ID. Bytes 12-n : The value of the object job-info. required-field.optional-field.job-id. All multi-byte values stored in Motorola (big-endian) format, where the most significant byte occurs first. Additional information: LaserJet 6P will use this object to report changes of the job-info-pages-printed and job-info-state objects. Therefore, the optional-field will always be zeroes and, because both of these are integers, the value portion of the data will always be four bytes.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

current-job-parsing-id 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.2.1.1
Contains the printer assigned job identification for the job currently being processed by the processing PDL sub- system. The job ID is a monotonically increasing number. The job ID may be reset to zero at power-up and may roll over to zero after reaching some maximum value. Additional information: A value of -1 is returned when the printer is not parsing a job. When data for a new job is detected, this object is updated (the job may or may not turn out to be a Null Job); however, the trap does not occur until the printer determines that it is not a Null Job (a trapped value will differ from the previous value by one or more). Some JOB-INFO- objects are created when the first data bytes are received. If the printer determines that the job is a Null Job, the JOB-INFO- objects related to the Null Job are deleted. LaserJet 6P retains the JOB-INFO- objects for the 12 most recent jobs that are not Null Jobs. LaserJet 6P resets the job ID to zero at power-up and will increment it to 32767 before rolling it to zero. To distinguish whether a power cycle or a rollover caused an id of zero, the object prtGeneralConfigChanges can be watched and if it increments at the same time as CURRENT-JOB-PARSING-ID goes to zero, then a power cycle is the most likely cause.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -1..32767  

job-info-name1 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.1
Contains the first part of this print job's name. The last OID field for this dynamic object contains the job ID. Additional information: The job name is the string specified by the NAME= parameter of the @PJL JOB command which allows a maximum of 80 characters. The first 40 characters are in this object and the second 40 are in JOB-INFO-NAME2. The symbol set is Roman-8. When jobs are nested, the value assigned to this object is the name provided by the most recent @PJL JOB NAME= command. If no name is is provided, a null string is returned. Whenever a @PJL JOB NAME= command is received, the trap occurs even if the name is the same.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

job-info-name2 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.2
Contains the second part of this print job's name. The last OID field for this dynamic object contains the job ID. Additional information: See JOB-INFO-NAME1-1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

job-info-stage 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.10
Indicates what printer sub-systems are currently processing this print job. The last OID field for this dynamic object contains the job ID. cSourceSubsystem - some of the job is in the printer I/O subsystem. cProcessingSubsystem - some of the job is in the printer imaging processing subsystem. cDestinationSubsystem - some of the job is being printed. Additional information: For LaserJet 6P cSourceSubsystem and cProcessingSubsystem will always be set and cleared together. A non-printing job will never set cDestinationSubsystem. When a page is ready to be printed, cDestinationSubsystem will be set even if a page of a previous job is currently being printed. cDestinationSubsystem remains set until the last page of the job has reached an output bin. If a page requires extensive processing and allows all the previous pages of a job to complete printing cDestinationSubsystem will remain set until the last page of the job is closed.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING  

job-info-io-source 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.11
Indicates which I/O source, the print job was received over. The value maps to port numbering scheme supported in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

job-info-pages-processed 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.12
Indicates the number of pages processed by the processing subsystem. If neither the cSourceSubsystem or the cProcessingSubsystem items are in the associated JOB-INFO-STAGE object, then this object contains the total number of pages processed for this job. The last OID field for this dynamic object contains the job ID. Additional information: This object is incremented by one when a page is processed, regardless of the number of pages that are printed as a result of the single page processed. In other words, it does not matter how many identical copies of a page are printed, or no pages may be printed if operating in silent run mode, this count is incremented only once. A page is considered processed when all of the input data has been processed for a page (the intermediate has been produced); the image of the page is not necessarily completely formed.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

job-info-pages-printed 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.13
Indicates the number of pages printed by the destination subsystem. If non of the cSourceSubsystem, cProcessingSubsystem or cDestinationSubsystem items are in the associated JOB-INFO-STAGE object, then this object contains the total number of pages printed for this job. This value may increase by two each time for duplex jobs. The last OID field for this dynamic object contains the job ID. Additional information: If multiple copies of a page are printed, each copy is counted individually.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

job-info-size 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.14
Indicates the number of bytes of data processed by the processing subsystem. If neither of the cSourceSubsystem or cProcessingSubsystem items are in the associated JOB-INFO-STAGE object, then this object contains the size of this job, in bytes. The last OID field for this dynamic object contains the job ID. Additional information: This count may be incremented by values other than one as blocks of data are processed; blocks of data (which may be as large as 2K bytes) will be processed in a varying amount of time. When a job completes, this count may not be the same as the total number of bytes sent to the printer since some data before or after the job may be considered to be outside the job. Also, for ill-formed PostScript jobs (ones that do not use the ENTER LANGUAGE command) will be reported as having approximately 256 extra bytes due to the way the language switching is accomplished.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

job-info-state 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.15
Indicates the state of the job. The last OID field for this dynamic object contains the job ID. eAborted - the print job was aborted. eWaitingForResources - the print job requires resources that are not currently available. Example resources that can cause the job to wait include the print engine or PDL processor being unavailable. The print engine could be unavailable due to paper out, paper jam, staple out, stapler jam, marking agent low, output bin full, etc. The PDL processor could be unavailable due to an off-line condition. Each printer specific object specification should state which conditions cause a job to be waiting for resources and also state which objects can be retrieved by an application to determine the exact cause of a resource being unavailable. ePrinted - the job has printed. The related JOB-INFO- OUTCOME object indicates if any problems were encountered while the job was processed. eRetained - the job can be reprinted. eTerminating - the job was aborted or cancelled and is currently is terminating. eInterrupted - the job has been interrupted. The job can be continued. ePaused - the job has been paused. The job can be continuted. eCancelled - the job has been cancelled. eProcessing - the job is currently being printed normally.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER eAborted(3), eWaitingForResources(4), ePrinted(5), eTerminating(7), eCancelled(10), eProcessing(11)  

job-info-outcome 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.19
Indicates if any warning or error conditions were encountered while processing the assoicated job. The last OID field for this dynamic object contains the job ID.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER eOk(3), eWarningsEncountered(4), eErrorsEncountered(5)  

job-info-outbins-used 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.20
Indicates which output bins this job has delivered printed pages to. The last OID field for this dynamic object contains the job ID. Additional information: LaserJet 6P has only 1 output bin. cOutbin1 is the top/face-down bin.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING  

job-info-physical-outbins-used 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.22
Indicates which physical output bins this job has delivered printed pages to. The last OID field for this dynamic object contains the job ID. Additional information: LaserJet 6P only has one output bin so this will always be set to cOutbin1. cOutbin1--Face-up bin
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING  

job-info-attr-1 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.1
Returns the value that was set in PJL via the SET JOBATTR= command. Attribute objects are saved sequentially, starting with 1, after the start of a job. If more attributes are set than there are objects to store them, the excess JOBATTR values are ignored. If the corresponding SET JOBATTR= command has not been received when a get is done for this object, a status of will be returned.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-2 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.2
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-3 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.3
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-4 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.4
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-5 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.5
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-6 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.6
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-7 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.7
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-8 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.8
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-9 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.9
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-10 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.10
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-11 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.11
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-12 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.12
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-13 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.13
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-14 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.14
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-15 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.15
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

job-info-attr-16 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.16
Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..80)  

io-timeout 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.1
The amount of time, in seconds, to wait for more print job data to be received before an I/O timeout occurs. The I/O channel being timed is the I/O channel that received the data associated with the current print job. If an I/O timeout occurs, the PDL processing sub-system assumes all the data associated with the current print job has been received, and processes the end of job in an PDL specific manner. The POS specifies the supported values. Additional information: IF an I/O timeout occurs,the PDL processing sub-system will consider it an end of job condition only if there is data from another I/O subsystem waiting to be processed. The supported values are 5 to 300 seconds. Setting to a value outside the supported range returns status.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 5..300  

io-switch 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.2
Indicates if the device will switch between I/O channels when a job boundary is encountered and print job data is available on another I/O channel.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER eYes(1)  

io-buffering 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.5
Returns or controls the manner in which the device performs I/O data buffering. I/O data buffering allows additional print job data to be buffered by the I/O sub- system in an effort to allow the computer sending the data to perform other tasks and to keep the PDL processing sub-system busy. eOff, I/O buffering is disabled. When eOn, I/O buffering is enabled and the IO-BUFFER-SIZE object controls the amount of memory set aside for I/O buffer. When eAuto, I/O buffering is enabled and the I/O buffer size is determined automatically by the device and the IO-BUFFER-SIZE object is not used. Additional information: In a PCL-only printer, all values may be set at any time. When PostScript is intalled and there is less than 6M of memory installed, setting this object to eOn or eAuto will caue to be returned. When PostScript and 6M or more is installed, all values are valid, provided Resource Saving has not consumed the needed memory.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eOff(1), eOn(2), eAuto(3)  

io-buffer-size 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.6
Returns or configures the amount of memory, in bytes, dedicated to I/O print job data buffering. Attempting to set to an unsupported value causes the device to use the closest supported value. Each device POS should document the list of supported values. Additional information: In LaserJet 6P the minimum supported value is 10,240. The maximum supported value is dependent on total memory installed and the amount of memory currently being used by other memory consumers. The buffer size must be a multiple of 1024, with the minimum value being 10,240. Setting to an unsupported value causes the printer to substitute the nearest value that is a multiple of 10,240 (if <100K) or 102,400 (if > 100K) and to return status. Examples of substituted values: <= 15,360 will snap to 10,240 > 15,360 and <= 25,600 will snap to 20,480 > 25,600 and <= 35,840 will snap to 30,720 > 35,840 and <= 46,080 will snap to 40,960 > 46,080 and <= 56,320 will snap to 51,200 > 56,320 and <= 66,560 will snap to 61,440 > 66,560 and <= 76,800 will snap to 71,680 > 76,800 and <= 87,040 will snap to 81,920 > 87,040 and <= 97,280 will snap to 92,160 > 97,280 and <= 153,600 will snap to 102,400 > 153,600 and <= 256,000 will snap to 204,800 > 256,000 and <= 358,400 will snap to 307,200 > 358,400 and <= 460,800 will snap to 409,600 > 460,800 and <= 563,200 will snap to 512,000 > 563,200 and <= 665,600 will snap to 614,400 > 665,600 and <= 768,000 will snap to 716,800 > 768,000 and <= 870,400 will snap to 819,200 > 870,400 and <= 972,800 will snap to 921,600 > 972,800 and <= 1,075,200 will snap to 1,024,000 > 1,075,200 and <= 1,177,600 will snap to 1,126,400 > 1,177,600 and <= 1,280,000 will snap to 1,228,800 etc. up to the maximum supported amount of memory. Attempting to set this object when IO-BUFFERING is eOff will cause a status of to be returned. When IO-BUFFERING is eOff, reading this object will return a value of zero. In base memory (2MB) the IO-BUFFER is eAuto, the IO-BUFFER-SIZE will be 0, if IO-BUFFER is turned eOn, then the IO-BUFFER-SIZE will be 10,240
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

maximum-io-buffering-memory 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.7
Returns the maximum amount of additional memory, in bytes, that can be dedicated to buffering print job data. Additional information: The following table can be used to determine the maximum amount of memory available for IO-BUFFERING: Total RAM No PostScript With PostScript 2 Min 10K N/A Max 100K N/A Def 0K N/A 3 Min 10K Min 10K Max 1000K Max 100K Def 100K Def 0 4 Min 10K Min 10K Max 2000K Max 100K Def 200K Def 0 5 Min 10K Min 10K Max 3000K Max 100K Def 300K Def 0 6 Min 10K Min 10K Max 4000K Max 100K Def 400K Def 0 7 Min 10K Min 10K Max 5100K Max 100K Def 500K Def 0 8 Min 10K Min 10K Max 6100K Max 100K Def 600K Def 0 9 Min 10K Min 10K Max 7100K Max 100K Def 700K Def 0 10 Min 10K N/A Max 8100K N/A Def 800K N/A 11 Min 10K Min 10K Max 9200K Max 100K Def 900K Def 0 12 Min 10K Min 10K Max 10200K Max 1000K Def 1000K Def 100K 13 Min 10K Min 10K Max 11200K Max 2000K Def 1100K Def 200K 14 Min 10K N/A Max 12200K N/A Def 1200K N/A 15 Min 10K Min 10K Max 13300K Max 4000K Def 1300K Def 400K 16 Min 10K N/A Max 14300K N/A Def 1400K N/A 17 N/A N/A N/A N/A N/A N/A 18 Min 10K N/A Max 16300K N/A Def 1600K N/A 19 Min 10K Min 10K Max 17400K Max 8100K Def 1700K Def 800K 20 Min 10K Min 10K Max 18400K Max 9200K Def 1800K Def 900K 21 Min 10K Min 10K Max 19400K Max 10200K Def 1900K Def 1000K 22 Min 10K N/A Max 20400K N/A Def 2000K N/A 23 Min 10K Min 10K Max 21500K Max 12200K Def 2100K Def 1200K 24 Min 10K N/A Max 22500K N/A Def 2200K N/A 25 N/A N/A N/A N/A N/A N/A 26 Min 10K N/A Max 24500K N/A Def 2400K N/A 27 Min 10K Min 10K Max 25600K Max 16300K Def 2500K Def 1600K
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

default-copies 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.4
Returns or changes default copies. Default copies is the default values used by the PDL to control the number of copies of each page in the print job that are printed. The print job can override this value. The list of supported values should be documented in the device POS. Additional information: The supported values are 1 through 999. Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snaps are as follows: <1 snaps to 1 >999 snaps to 999
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 1..999  

form-feed 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.5
Instructs the PDL processing sub-system to finishing processing the current page of the current job. Form feed is also known as close page or eject page. If the PDL processing sub-system is in a FORM-FEED-NEEDED state, this causes the device to flush or finish processing the current page of the current job. If the device is not in the FORM-FEED-NEEDED state, an will occur.
Status: optional Access: write-only
OBJECT-TYPE    
  INTEGER eInitiateAction(1)  

resource-saving 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.6
Returns or changes PDL resource saving. Resource saving stores a PDL's permanent soft resources, like fonts, even when another PDL is active. Resource saving is also called environment saving. When eOff, resource saving is disabled. When ON, resource saving is enabled and memory is set aside for each PDL based on that PDL's resource saving memory size object, to store that PDL's permanent soft resources. When eAuto, resource saving is enabled and memory space for each installed PDL is determined automatically. The device POS should document what values are legal when only one PDL is installed. Additional information: When PCL is the only PDL installed in LaserJet 6P, eOn is not a legal value. Attempting to set this object to eOn with a PCL-only printer will result in a status of being returned. When PostScript and 12M or more are installed, all values are valid, provided I/O Buffering has not consumed the needed memory. Refer to the MAXIMUM-RESOURCE-SAVING-MEMORY table for a list of maximum and default memory configurations. This object is only supported if PostScript option is installed.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eOff(1), eOn(2), eAuto(3)  

maximum-resource-saving-memory 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.7
Returns the maximum amount of additional memory, in bytes, that can be dedicated to holding PDL permanent soft resources. Additional information: The following numbers assume that IO-BUFFERING=eOff; if IO-BUFFERING<>eOff, the following numbers will be reduced by the value of IO-BUFFER-SIZE. Memory for resource saving is allocated in increments of 102400 bytes. Therefore, for each 1M (1048576 bytes) of memory added to the printer, 102400 bytes are made available to resource saving (and I/O buffering) and 24576 bytes are retained until an additional 102400 byte block can be made available. The value reported by this object is always rounded down to the nearest multiple of 102400. For a PCL-only printer, the value of this object is zero (all resource saving memory is dedicated to PCL). The table below describes the memory available for Resource Saving with PostScript Installed, assuming that no other personality resource or I/O buffering is being done. Total RAM Minimum Maximum Default 2 N/A N/A N/A 3 N/A N/A N/A 4 N/A N/A N/A 5 N/A N/A N/A 6 N/A N/A N/A 7 N/A N/A N/A 8 N/A N/A N/A 9 N/A N/A N/A 10 N/A N/A N/A 11 N/A N/A N/A 12 0K 1000K 800K 13 0K 2000K 1000K 14 N/A N/A N/A 15 0K 4000K 1400K 16 N/A N/A N/A 17 N/A N/A N/A 18 N/A N/A N/A 19 0K 8100K 2200K 20 0K 9200K 2400K 21 0K 10200K 2600K 22 N/A N/A N/A 23 0K 12200K 3000K 24 N/A N/A N/A 25 N/A N/A N/A 26 N/A N/A N/A 23 0K 16300K 3800K
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

default-vertical-black-resolution 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.8
Returns or changes the value of the default vertical black resolution. The units are dots per inch. Additional information: In LaserJet 6P changing this OID also causes DEFAULT- HORIZONTAL-BLACK RESOLUTION to change. DEFAULT- HORIZONTAL-BLACK-RESOLUTION and DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the same. The supported values are 300 and 600. Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snap values are as follow: <450 snap to 300 >=450 snap to 600
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

default-horizontal-black-resolution 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.9
Returns or changes the value of the default horizontal black resolution. The units are dots per inch. Additional information: In LaserJet 6P changing this OID also causes DEFAULT- VERTICAL-BLACK RESOLUTION to change. DEFAULT- HORIZONTAL-BLACK-RESOLUTION and DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the same. The supported values are 300 and 600. Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snap values are as follow: <450 snap to 300 >=450 snap to 600
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

default-page-protect 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.10
Returns or changes the default page protection behavior. If eOff, the device does not reserve memory for holding the entire raster form of a processed page. If eOn, then memory is reserved. If eAuto, the device determines the amount of memory to reserve. Additional information: Setting to eOn causes MET to be more conservative, but it will not allocate memory to hold an entire rasterized page.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eOn(2), eAuto(3)  

default-lines-per-page 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.11
Returns or changes the default number of lines per page. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return the . Additional information: The supported values in LaserJet 6P are 5 to 128. Setting to an unsupported value causes the the printer to substitute in a snap value and to return status. The snap values are as follow: <5 snaps to 5 >128 snaps to 128
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

default-vmi 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.12
Returns or changes the default vertical motion index. The unit of measure for VMI is centipoints per line. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return .
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

default-media-size 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.13
This indicates the default media size. A write of an unsupported value cases an . Complete list of supported media sizes along with their dimensions are listed in the ''Media Size Table'' near the end of this document.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eUSExecutive(1), eUSLetter(2), eUSLegal(3), eISOandJISA4(26), eISOandJISA5(25), eJISB5(45), eJapanesePostcardSingle(71), eJapanesePostcardDouble(72), eMonarch(80), eCommercial10(81), eInternationalDL(90), eInternationalC5(91), eInternationalB5(100), eCustom(101)  

cold-reset-media-size 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.19
Returns or sets the media size that is used as the DEFAULT-MEDIA-SIZE when a cold reset occurs.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eUSLetter(2), eISOandJISA4(26)  

form-feed-needed 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.2.2
Indicates if the PDL processing sub-system has made marks on the current page and the source subsystem has been idle for a device specific amount of time. Additional information: LaserJet 6P will set this object to eTrue when it has made marks on the current page, the IO-TIMEOUT has expired and no data is pending on another I/O. Once it is set to eTrue, more data on the same I/O will cause this object to be set to eFalse, until the above conditions are met again.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER eFalse(1), eTrue(2)  

pcl-resource-saving-memory-size 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.2
Returns or changes the amount of resource saving memory set aside to hold permanent soft PCL resources. Additional information: The value returned by this object is the amount of Resource Saving memory currently dedicated to PCL, regardless of the value of RESOURCE-SAVING. For a PCL-only printer, the value of this object is zero. All memory is dedicated to PCL, but it is not shown as such. If PostScript is installed, the default value of this object is as follows: Zero if <12M memory is installed. Zero if RESOURCE-SAVING=eOff. 409600 if 12M memory is installed and RESOURCE-SAVING=eOn. 409600 if 12M memory is installed and RESOURCE-SAVING=eAuto; plus 102400 for each 1M over 12M memory installed. If RESOURCE-SAVING=eOn, this object can be used to set the amount of Resource Saving memory currently dedicated to PCL. The values supported are zero (to turn resource saving off for PCL) and 409600 through 409600 plus the value of MAXIMUM-RESOURCE-SAVING-MEMORY, in increments of 102400. If a value is received that is between 1 and 409599, it will be snapped to 409600 and a status of returned. If an unsupported value greater than 409600 is received, it will be snapped down to the nearest 102400 value and a status of returned. Attempting to set this object when RESOURCE-SAVING is eAuto or eOff will cause a status of to be returned.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

pcl-default-font-height 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.13
Returns or changes the default PCL height. Height is an approximate measure of the body of the type in centipoints. A centipoint is 1/7200 inch. Height applies only to proportional fonts. Point size, in points, can be converted to font height, in centipoints, by multiplying the point size by 100. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return .''Closest'' means the smallest absolute difference. Additional information: Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snap values are as follow: <=400 snaps to 400 >=99975 snaps to 99975 Unsupported values in the range 400 to 99975 snaps DOWN to the previous supported value (i.e 25293 snaps to 25275 or 75038 snaps to 75025).
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

pcl-default-font-source 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.14
Returns or changes the value of the default font source variable in NVRAM.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eInternal(1), ePermanentSoft(2), eRomSimm1(10), eRomSimm2(11), eRomSimm3(12), eRomSimm4(13)  

pcl-default-font-number 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.15
Returns or changes the value of the default font number variable in NVRAM. Writing an unsupported value causes the printer to generate an . Additional information: Valid numbers or 0 - 255, but only font numbers that are included in the PCL FONT LIST are selectable.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

pcl-default-font-width 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.16
Returns or changes the default PCL font width. Width is expressed as the width of a character in centipoints. A centipoint is 1/7200 inch. Width applies only to fixed space fonts. Pitch, in character per inch, can be converted to font width, in centipoints, by dividing 7200 by the pitch. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return . ''Closest'' means the smallest absolute difference. Additional information: Setting to an unsupported value causes the printer to substitue in a snap value (listed below) and return status. The snap values for pitch are as follow: <=44 snaps to 44 >=9999 snaps to 9999
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

postscript-resource-saving-memory-size 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.2
Returns or changes the amount of resource saving memory set aside to hold permanent soft PostScript resources. Additional information: The value returned by this object is the amount of Resource Saving memory currently dedicated to PostScript, regardless of the value of RESOURCE-SAVING. The following table shows the Maximum memory available for Resource Saving in each of the memory configurations, assuming no other personality or I/O buffering is being done in the printer. If RESOURCE-SAVING=eOn, this object can be used to set the amount of Resource Saving memory currently dedicated to PostScript. The values supported are zero (to turn resource saving off for PCL) and 409600 through 409600 plus MAXIMUM-RESOURCE-SAVING-MEMORY, in increments of 102400. If a value is received that is between 1 and 409599, it will be snapped to 409600 and a status of returned. If an unsupported value greater than 409600 is received, it will be snapped down to the nearest 102400 value and a status of returned. Attempting to set this object when RESOURCE-SAVING is eAuto or eOff will cause a status of to be returned.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

postscript-print-errors 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.11
Returns or changes the value of the print PostScript errors setting. If eOn, PostScript prints an error page showing the error encountered and the stack at the time of the error. Additional information: This object is only supported if PostScript option is installed.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eOff(1), eOn(2)  

postscript-jam-recovery 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.12
Returns or changes the PostScript jam recovery setting. If eOn, then the device will reprint PostScript pages, if those pages jam. Additional information: This object is only supported if PostScript option is installed.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eOff(1), eOn(2)  

pjl-password 1.3.6.1.4.1.11.2.3.9.4.2.1.3.5.1
Returns PJL password, if the password is not set (zero). If the password is set, then attempting to retrieve the password causes an to occur and will return the .
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  


mp-tray 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.1.5
Returns or changes the value of the multi-purpose (MP) tray configuration variable. The MP tray can be configured to operate as an additional input tray (eCassette), a manual feed slot (eManual), or in a manner compatible with the LaserJet III manual feed slot (eFirst). If configured for eFirst, if media is present in the MP tray, that media is used (assuming the size matches and the print job didn't specify another tray) until the MP tray is empty. Additional information: The MP tray can be configured for use either as a paper cassette or as a priority manual feed tray. When the tray is configured as a manual feed tray, unsolicited status messages are not generated when there is no paper in the tray. LaserJet 6P will pull media from TRAY 1 only if there is a sheet present.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eCassette(2), eFirst(3)  

default-ret 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.6.5
Returns or changes the Resolution Enhancement Technology setting. Devices that only support eOff and on should map all other values to on and always return the same non-eOff value to indicate on. The list of supported values should be documented in the device POS. Additional information: This item may also be set via PJL. Setting this object may cause a status of to be returned, but the new value will not take effect until a job boundary is reached. If a get is done on object before the job boundary is reached, the value last set will be returned.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER eOff(1), eLight(2), eMedium(3), eDark(4)  

default-print-quality 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.6.7
Returns or sets the default print quality. A value of zero has the lowest print quality. A value of 100 has the highest print quality. Each POS should document what values in the 0 to 100 range are supported. Additional information: In LaserJet 6P, the supported values are 0 and 100. A value of zero has the lowest print quality(ECONOMODE=ON), thus minimizes the amount of toner used to print a page. A value of 100 has the highest print quality (ECONOMODE=OFF), thus uses more toner to print a page. Setting to an unsupported value outside of the 0 to 100 range causes the printer to return status. Setting to an unsupported value inside of the 0 to 100 range causes the printer to substitute in a snap value (listed below) and to return status. The snap values are as follow: 0 to 50 snap to 0 51 to 100 snap to 100
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

channel-bytes-sent 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.2
The low order 31 bits of the number of bytes sent from the printer to the host on this logical channel.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

channel-bytes-received 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.3
The low order 31 bits of the number of bytes received by the printer from the host on this logical channel.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

channel-io-errors 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.4
The low order 31 bits of the number of I/O errors which have occured on this logical channel.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

channel-jobs-received 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.5
The low order 31 bits of the number of print jobs which have been received on this logical channel.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

hrmemorysize 1.3.6.1.4.1.11.2.3.9.4.2.3.2.2
The amount of physical main memory contained by the host. Additional information: The unit of measure for this object is 1024 bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hrstorageindex 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.1
A unique value for each logical storage area contained by the host.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

hrstoragetype 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.2
The type of storage represented by this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

hrstoragedescr 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.3
A description of the type and instance of the storage described by this entry. Additional information: This object is not localized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hrstorageallocationunits 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.4
The size, in bytes, of the data objects allocated from this pool. If this entry is monitoring sectors, blocks, buffers, or packets, for example, this number will commonly be greater than one. Otherwise this number will typically be one. Additional information: Unit is one byte.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

hrstoragesize 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.5
The size of the storage represented by this entry, in units of hrStorageAllocationUnits. Additional information: Total formatter RAM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

hrstorageused 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.6
The amount of the storage represented by this entry that is allocated, in units of hrStorageAllocationUnits. Additional information: This object should not be used when creating a print job for the device because the amount of memory in use will likely be different when the printer processes the print job.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

hrstorageallocationfailures 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.7
The number of requests for storage represented by this entry that could not be honored due to not enough storage. It should be noted that as this object has a SYNTAX of Counter, that it does not have a defined initial value. However, it is recommended that this object be initialized to zero. Additional information: This object is set to zero at power on and when any reset is done via prtGeneralReset. This object is incremented whenever the printer is short on memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hrdeviceindex 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.1
A unique value for each device contained by the host. The value for each device must remain constant at least from one re-initialization of the agent to the next re-initialization. Additional information: The entry in the Device Table which describes the printer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

hrdevicetype 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.2
An indication of the type of device. If this value is `hrDeviceProcessor { hrDeviceTypes 3 }' then an entry exists in the hrProcessorTable which corresponds to this device. If this value is `hrDeviceNetwork { hrDeviceTypes 4 }', then an entry exists in the hrNetworkTable which corresponds to this device. If this value is `hrDevicePrinter { hrDeviceTypes 5 }', then an entry exists in the hrPrinterTable which corresponds to this device. If this value is `hrDeviceDiskStorage { hrDeviceTypes 6 }', then an entry exists in the hrDiskStorageTable which corresponds to this device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

hrdevicedescr 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.3
A textual description of this device, including the device's manufacturer and revision, and optionally, its serial number. Additional information: This object is not localized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hrdeviceid 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.4
The product ID for this device. Additional information: The complete OID reported by this object is: .1.3.6.1.4.1.11.2.3.9.1.2.3
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

hrdevicestatus 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.5
The current operational state of the device described by this row of the table. A value unknown(1) indicates that the current state of the device is unknown. running(2) indicates that the device is up and running and that no unusual error conditions are known. The warning(3) state indicates that agent has been informed of an unusual error condition by the operational software (e.g., a disk device driver) but that the device is still 'operational'. An example would be high number of soft errors on a disk. A value of testing(4), indicates that the device is not available for use because it is in the testing state. The state of down(5) is used only when the agent has been informed that the device is not available for any use. Additional information: The printer's condition is mapped as follows: eHrunning -- Printer ready to print or is printing. May be in power save mode. eHwarning -- A condition exists that needs attention but it is not currently preventing printing. A non-critical alert is active. eHtesting -- Printer is printing an internal page. eHdown -- Printer is not printing due to an error condition. A critical alert is active, human interaction is needed to bring the printer to a ready state or the printer is offline.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER eHrunning(2), eHwarning(3), eHtesting(4), eHdown(5)  

hrdeviceerrors 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.6
The number of errors detected on this device. It should be noted that as this object has a SYNTAX of Counter, that it does not have a defined initial value. However, it is recommended that this object be initialized to zero. Additional information: This is the number of critical alerts that have been entered into the alert table since the device was powered on. The maximum value for this object is 2^32-1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hrprinterstatus 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5.1.1
The current status of this printer device. When in the idle(1), printing(2), or warmup(3) state, the corresponding hrDeviceStatus should be running(2) or warning(3). When in the unknown state, the corresponding hrDeviceStatus should be unknown(1). Additional information: The printer's condition is mapped as follows: eHidle -- The printer is not doing any of the items listed below for eHprinting status. eHprinting -- The printer is processing PJL or PDL data, waiting for an error condition to be cleared, processing a control panel request, waiting for the engine to become ready or printing images. eHwarmup -- If hrDeviceStatus is eHdown, then the printer is currently offline but is resolving the condition that caused it be offline it will be online when it is ready to print. If hrDeviceStatus is eHrunning, then the printer was in power save mode and is now becoming ready to print.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER eHother(1), eHidle(3), eHprinting(4), eHwarmup(5)  

hrprinterdetectederrorstate 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5.1.2
This object represents any error conditions detected by the printer. The error conditions are encoded as bits in an octet string, with the following definitions: Condition Bit # hrDeviceStatus lowPaper 0 warning(3) noPaper 1 down(5) lowToner 2 warning(3) noToner 3 down(5) doorOpen 4 down(5) jammed 5 down(5) offline 6 down(5) serviceRequested 7 warning(3) If multiple conditions are currently detected and the hrDeviceStatus would not otherwise be unknown(1) or testing(4), the hrDeviceStatus shall correspond to the worst state of those indicated, where down(5) is worse than warning(3) which is worse than running(2). Bits are numbered starting with the most significant bit of the first byte being bit 0, the least significant bit of the first byte being bit 7, the most significant bit of the second byte being bit 8, and so on. A one bit encodes that the condition was detected, while a zero bit encodes that the condition was not detected. This object is useful for alerting an operator to specific warning or error conditions that may occur, especially those requiring human intervention. Additional information: LaserJet 5 reports error conditions as follows: noPaper -- A tray is empty and must be filled for printing to continue. hrDeviceStatus = eHdown; hrPrinterStatus = eHother; a non-critical alert is active. noToner -- LaserJet 5 does not report this condition. doorOpen -- A door is open. hrDeviceStatus = eHdown; hrPrinterStatus = eHother; a non-critical alert is active. jammed -- A jam condition is preventing printing. hrDeviceStatus = eHdown; hrPrinterStatus = eHother; a non-critical alert is active. serviceRequested -- Any status or error condition not listed above. If the condition prevents printing, the 'offline' bit is also set and its hrDeviceStatus and hrPrinterStatus would prevail. hrDeviceStatus = eHwarning; hrPrinterStatus = eHidle or eHprinting; a non-critical alert is active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtgeneralconfigchanges 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.1
Counts configuration changes that change the capabilities of a printer, such as the addition/deletion of input/output bins, the addition/deletion of interpreters, or changes in media size. Such changes will often affect the capability of the printer to service certain types of print jobs. Management applications may cache infrequently changed configuration information about sub-units on the printer. This object should be incremented whenever the agent wishes such applications to invalidate that cache and re-download all of this configuration information, thereby signalling a change in the printer's configuration. For example, if an input tray that contained paper of different dimensions was added, this counter would be incremented. As an additional example, this counter would not be incremented when an input tray is removed or the level of an input device changes. Additional information: This is a 32 bit counter (unsigned). When it reaches its maximum value, it will roll to zero.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtgeneralcurrentlocalization 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.2
The value of the prtLocalizationIndex corresponding to the current language, country, and character set to be used for localized string values that are identified as being dependent on the value of this object. Note that this object does not apply to localized strings in the prtConsole group or any object that is not identified as above. Additional information: The value of this object is saved in NVRAM.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 1..13  

prtgeneralreset 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.3
Setting this value to `powerCycleReset', `resetToNVRAM', or `resetToFactoryDefaults' will result in the resetting of the printer. When read, this object will always have the value `notResetting(3)', and a SET of the value `notResetting' shall have no effect on the printer. Some of the defined values are optional. However, every implementation must support at least the values `notResetting' and resetToNVRAM'. Additional information: The LaserJet 6P printer supports the values 'notResetting' and 'resetToNVRAM'. Setting this object to ePnotResetting cuases the printer to do no reset. Setting this object to ePpowerCycleReset causes LaserJet 6P to perform its power on initialization routines. All I/O buffers are reset and tests normally run at power on time are executed.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER ePnotResetting(3), ePresetToNVRAM(5)  

prtcoverdescription 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1.1.2
The manufacturer provided cover sub-mechanism name in the localization specified by prtGeneralCurrentLocalization.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

prtcoverstatus 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1.1.3
The status of this cover sub-unit.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePdoorOpen(3), ePdoorClosed(4)  

prtlocalizationlanguage 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1.2
A two character language code from ISO 639. Examples EN, GB, CA, FR, DE. Additional information: The languages supported by LaserJet 6P are English, Danish, Dutch, Finnish, French, German, Italian, Norwegian, Polish, Portuguese, Spanish, Swedish, Turkish.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..2)  

prtlocalizationcountry 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1.3
A two character country code from ISO 3166, a blank string (two space characters) shall indicate that the country is not defined. Examples: US, FR, DE, ... Additional information: The languages supported by LaserJet 6P (and corresponding country) are English (United States), Danish (Denmark), Dutch (Netherlands), Finnish (Finland), French (France), German (Germany), Italian (Italy), Norwegian (Norway), Polish (Poland), Portuguese (Portugal), Spanish (Spain), Swedish (Sweden), Turkish (Turkey)
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..2)  

prtlocalizationcharacterset 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1.4
The coded character set used for this localization.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePcsHPRoman8(2004), ePcsISOLatin2(5), ePcsISOLatin5(12)  

prtstoragerefindex 1.3.6.1.4.1.11.2.3.9.4.2.2.5.2.1.2
The value of the hrDeviceIndex of the printer device that this storageEntry is associated with.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

prtdevicerefindex 1.3.6.1.4.1.11.2.3.9.4.2.2.5.3.1.2
The value of the hrDeviceIndex of the printer device that this deviceEntry is associated with.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

prtgeneralcurrentoperator 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.4
The name of the current human operator responsible for operating this printer. It is suggested that this string include information that would enable other humans to reach the operator, such as a phone number. Additional information: The maximum supported string length is 32 characters. Length of 32 was chosen so a phone number could be included with the name. If the user entered string is too long, the device will store as much as possible and will return the status.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

prtgeneralserviceperson 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.5
The name of the last human responsible for servicing this printer. It is suggested that this string include information that would enable other humans to reach the service person, such as a phone number. Additional information: The maximum supported string length is 32 characters. Length of 32 was chosen so a phone number could be included with the name. If the user entered string is too long, the device will store as much as possible and will return the status.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

prtinputdefaultindex 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.6
The value of prtInputIndex corresponding to the default input sub-unit: that is, this object selects the default source of input media. Additional information: The default input tray is determined by the printer based on DEFAULT-MEDIA-SIZE. If Tray 1 is set in FIRST mode then the size of paper loaded in Tray 1 is assumed to be the requested size and the printer will pick from Tray 1 without regard to the requested size.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

prtinputtype 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.2
The type of technology (discriminated primarily according to feeder mechanism type) employed by the input sub-unit. Note, the Optional Input Class provides for a descriptor field to further qualify the other choice. Additional information: Tray 1 is the multi-purpose tray and is always present. It supports both sheets and envelopes. Its type is ePsheetFeedAutoNonRemovableTray. Tray 2 is a removable tray that comes standard with the printer, although it is usually not removed from the printer. It is type ePsheetFeedAutoRemovableTray.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePunknown(2), ePsheetFeedAutoRemovableTray(3), ePsheetFeedAutoNonRemovableTray(4), ePsheetFeedManual(5), ePcontinuousRoll(6), ePcontinuousFanFold(7)  

prtinputdimunit 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.3
The unit of measurement for use calculating and relaying dimensional values for this input sub-unit.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePtenThousandthsOfInches(3), ePmicrometers(4)  

prtinputmediadimfeeddirdeclared 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.4
This object provides the value of the declared dimension, in the feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The feed direction is the direction in which the media is fed on this sub-unit. This dimension is measured in input sub-unit dimensional units (prtInputDimUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests. Otherwise, the value may be changed. The value (-1) means other and specifically means that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. Additional information: For tray 1 the value is the dimension for the media size currently declared. Valid values are 63000 to 140000 if prtInputDimUnit is ePtenThousandthsOfInches and 160000 to 356000 if prtInputDimUnit is ePmicrometers.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtinputmediadimxfeeddirdeclared 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.5
This object provides the value of the declared dimension, in the cross feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The cross feed direction is ninety degrees relative to the feed direction associated with this sub-unit. This dimension is measured in input sub-unit dimensional units (prtInputDimUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests. Otherwise, the value may be changed. The value (-1) means other and specifically means that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. Additional information: For tray 1 the value is the dimension for the media size currently declared. Valid values are 35000 to 85000 if prtInputDimUnit is ePtenThousandthsOfInches and 90000 to 216000 if prtInputDimUnit is ePmicrometers.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtinputmediadimfeeddirchosen 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.6
The printer will act as if media of the chosen dimension (in the feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. Feed dimension measurements are taken parallel relative to the feed direction associated with that sub-unit and are in input sub-unit dimensional units (DimUnit). If the printer supports the declared dimension, the granted dimension is the same as the declared dimension. If not, the granted dimension is set to the closest dimension that the printer supports when the declared dimension is set. The value (-1) means other and specifically indicates that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. Additional information: When the tray is removed, a value of -2 is returned. The object for tray 1 and 2 returns the value of the media size for which the tray is currently configured because they cannot sense what size media it contains.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtinputmediadimxfeeddirchosen 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.7
The printer will act as if media of the chosen dimension (in the cross feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. The cross feed direction is ninety degrees relative to the feed direction associated with this sub-unit. This dimension is measured in input sub-unit dimensional units (DimUnit). If the printer supports the declared dimension, the granted dimension is the same as the declared dimension. If not, the granted dimension is set to the closest dimension that the printer supports when the declared dimension is set. The value (-1) means other and specifically indicates that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. Additional information: The default values assume the trays are configured for letter size paper. The objects for tray 1 and tray 2 returns the value of the media size for which the tray is currently configured because they cannot sense what size media it contains.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtinputcapacityunit 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.8
The unit of measurement for use in calculating and relaying capacity values for this input sub-unit. Additional information: A sheet is a single piece of 20 pound paper.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePtenThousandthsOfInches(3), ePmicrometers(4), ePsheets(8), ePfeet(16), ePmeters(17)  

prtinputmaxcapacity 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.9
The maximum capacity of the input sub-unit in input sub-unit capacity units (CapacityUnit). There is no convention associated with the media itself so this value reflects claimed capacity. If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. Additional information: This is specified assuming 20 pound paper for the paper trays.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtinputcurrentlevel 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.10
The current capacity of the input sub-unit in input sub-unit capacity units (CapacityUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (-3) means that the printer knows that at least one unit remains. Additional information: LaserJet 6P has no paper sensors so a value of -2 will always be returned.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtinputstatus 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.11
The current status of this input sub-unit. The status is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transitioning. These values are: Availability value Available and Idle 0 000'b Available and Standby 2 010'b Available and Active 4 100'b Available and Busy 6 110'b Unavailable and OnRequest 1 001'b Unavailable because Broken 3 011'b Unknown 5 101'b Non-Critical No Non-Critical Alerts 0 Non-Critical Alerts 8 Critical No Critical Alerts 0 Critical Alerts 16 On-Line Intended state is On-Line 0 Intended state is Off-Line 32 Transitioning At intended state 0 Transitioning to intended state 64
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtinputmedianame 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.12
A description of the media contained in this input sub-unit; This description is intended for display to a human operator. This description is not processed by the printer. It is used to provide information not expressible in terms of the other media attributes (e.g. prtInputMediaDimFeedDirChosen, prtInputMediaDimXFeedDirChosen, prtInputMediaWeight, prtInputMediaType). An example would be `legal tender bond paper'. Additional information: LaserJet 6P does not support the concept of named media types.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

prtinputname 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.13
The name assigned to this input sub-unit.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

prtinputvendorname 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.14
The vendor name of this input sub-unit.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

prtinputmodel 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.15
The model name of this input sub-unit. Additional information: LaserJet 6P does not specify a model name for the Tray1 or Tray2.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

prtinputversion 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.16
The version of this input sub-unit. Additional information: LaserJet 6P does not specify a version number for the input trays.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

prtinputserialnumber 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.17
The serial number assigned to this input sub-unit. Additional information: LaserJet 6P does not specify a serial number for the input trays.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

prtinputdescription 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.18
A free-form text description of this input sub-unit in the localization specified by prtGeneralCurrentLocalization.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

prtinputsecurity 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.19
Indicates if this input sub-unit has some security associated with it. Additional information: No security mechanism provided.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePon(3), ePoff(4), ePnotPresent(5)  

prtoutputdefaultindex 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.7
The value of prtOutputIndex corresponding to the default output sub-unit; that is, this object selects the default output destination. Additional information: LaserJet 6P has only one output bin, a face-down bin located at the top of the printer.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtoutputtype 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.2
The type of technology supported by this output sub-unit. Additional information: LaserJet 6P has only one output bin, a face-down bin located at the top of the printer.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePunknown(2), ePremovableBin(3), ePunRemovableBin(4), ePcontinuousRollDevice(5), ePmailBox(6), ePcontinuousFanFold(7)  

prtoutputcapacityunit 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.3
The unit of measurement for use in calculating and relaying capacity values for this output sub-unit. Additional information: A sheet is a single piece of 20 pound paper.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePtenThousandthsOfInches(3), ePmicrometers(4), ePsheets(8), ePfeet(16), ePmeters(17)  

prtoutputmaxcapacity 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.4
The maximum capacity of this output sub-unit in output sub-unit capacity units (CapacityUnit). There is no convention associated with the media itself so this value essentially reflects claimed capacity. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. Additional information: Note LaserJet 6P can not sense how much is in the output bin, but the product specifications say the output bin can hold 250 sheets.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtoutputremainingcapacity 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.5
The remaining capacity of the possible output sub-unit capacity in output sub-unit capacity units (CapacityUnit) of this output sub-unit. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be modified by management requests; otherwise, the value may be written The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (-3) means that the printer knows that there remains capacity for at least one unit. Additional information: LaserJet 6P does not have any sensing on the output bin, so it will always report unknown (-2).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtoutputstatus 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.6
The current status of this output sub-unit. The status is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transitioning. These values are: Availability value Available and Idle 0 000'b Available and Standby 2 010'b Available and Active 4 100'b Available and Busy 6 110'b Unavailable and OnRequest 1 001'b Unavailable because Broken 3 011'b Unknown 5 101'b Non-Critical No Non-Critical Alerts 0 Non-Critical Alerts 8 Critical No Critical Alerts 0 Critical Alerts 16 On-Line Intended state is On-Line 0 Intended state is Off-Line 32 Transitioning At intended state 0 Transitioning to intended state 64 Additional information: This is the only thing LaserJet 6P can return since it can not sense the output tray. 5 is Unknown Status.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkerdefaultindex 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.8
The value of prtMarkerIndex corresponding to the default markersub-unit; that is, this object selects the default marker. Additional information: LaserJet 6P only has one marker subunit.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

prtmarkermarktech 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.2
The type of marking technology used for this marking sub-unit.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePunknown(2), ePelectrophotographicLED(3), ePelectrophotographicLaser(4), ePelectrophotographicOther(5), ePimpactMovingHeadDotMatrix9pin(6), ePimpactMovingHeadDotMatrix24pin(7), ePimpactMovingHeadDotMatrixOther(8), ePimpactMovingHeadFullyFormed(9), ePimpactBand(10), ePimpactOther(11), ePinkjetAqueous(12), ePinkjetSolid(13), ePinkjetOther(14), ePpen(15), ePthermalTransfer(16), ePthermalSensitive(17), ePthermalDiffusion(18), ePthermalOther(19), ePelectroerosion(20), ePelectrostatic(21), ePphotographicMicrofiche(22), ePphotographicImagesetter(23), ePphotographicOther(24), ePionDeposition(25), ePeBeam(26), ePtypesetter(27)  

prtmarkercounterunit 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.3
The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a strip recorder that does not or cannot track the physical dimensions of the media and does not use characters, lines or sheets. Additional information: Since LaserJet 6P keeps track of pages printed, the counter unit will be defined as ePimpressions which would be like saying pages printed.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePtenThousandthsOfInches(3), ePmicrometers(4), ePcharacters(5), ePlines(6), ePimpressions(7), ePsheets(8), ePdotRow(9), ePhours(11), ePfeet(16), ePmeters(17)  

prtmarkerlifecount 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.4
The count of the number of units of measure counted during the life of printer using units of measure as specified by CounterUnit. Additional information: In LaserJet 6P the total engine page count is kept in NVRAM however the NVRAM value is only updated every 10 impressions. NOTE: The value returned by this OID will be incremented every page but if power is lost between NVRAM updates, up to 9 impressions of the page count may be lost. The counter will be reset to zero after 999999 pages. The page count is incremented when a sheet of media is pulled from an input tray.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkerpoweroncount 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.5
The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as specified by CounterUnit.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkerprocesscolorants 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.6
The number of process colors supported by this marker. A process color of 1 implies monochrome. The value of this object and SpotColorants cannot both be 0. Must be 0 or greater.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

prtmarkerspotcolorants 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.7
The number of spot colors supported by this marker. The value of this object and ProcessColorants cannot both be 0. Must be 0 or greater.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

prtmarkeraddressabilityunit 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.8
The unit of measure of distances. Additional information: This will always be ePtenThousandthsOfInches, no matter what COLD-RESET-MEDIA-SIZE is because we are talking about resolution and toner addressability, which is always dpi
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePtenThousandthsOfInches(3), ePmicrometers(4)  

prtmarkeraddressabilityfeeddir 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.9
The number of addressable marking positions in the feed direction per 10000 units of measure specified by AddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'. Additional information: Use this object to specify resolution. LaserJet 6P supports 300 or 600 dots per inch with 600 being the default.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkeraddressabilityxfeeddir 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.10
The number of addressable marking positions in the cross feed direction in 10000 units of measure specified by AddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'. Additional information: Use this object to specify resolution. LaserJet 6P supports 300 or 600 dots per inch with 600 being the default.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkernorthmargin 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.11
The margin, in units identified by AddressabilityUnit, from the leading edge of the medium as the medium flows throught the marking engine with the side to be imaged facing the observer. The leading edge is the North edge and the other edges are defined by the normal compass layout of directions with the compass facing the observer. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkersouthmargin 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.12
The margin from the South edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkerwestmargin 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.13
The margin from the West edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bouned by all four margins is guaranteed for all interpreters. The value (-2) means unknown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkereastmargin 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.14
The margin from the East edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkerstatus 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.15
The current status of this marker sub-unit. The status is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transitioning. These values are: Availability value Available and Idle 0 000'b Available and Standby 2 010'b Available and Active 4 100'b Available and Busy 6 110'b Unavailable and OnRequest 1 001'b Unavailable because Broken 3 011'b Unknown 5 101'b Non-Critical No Non-Critical Alerts 0 Non-Critical Alerts 8 Critical No Critical Alerts 0 Critical Alerts 16 On-Line Intended state is On-Line 0 Intended state is Off-Line 32 Transitioning At intended state 0 Transitioning to intended state 64
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkersuppliesmarkerindex 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.2
The value of prtMarkerIndex corresponding to the marking sub-unit with which this marker supply sub-unit is associated. Additional information: LaserJet 6P has just one marker supply, the toner cartridge, so this value is always 1.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

prtmarkersuppliescolorantindex 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.3
The value of prtMarkerColorantIndex corresponding to the colorant with which this marker supply sub-unit is associated. This value shall be 0 if there is no colorant table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

prtmarkersuppliesclass 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.4
Indicates whether this supply entity represents a supply container that is consumed or a receptacle that is filled.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePsupplyThatIsConsumed(3), ePreceptacleThatIsFilled(4)  

prtmarkersuppliestype 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.5
The type of this supply.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePunknown(2), ePtoner(3), ePwasteToner(4), ePink(5), ePinkCartridge(6), ePinkRibbon(7), ePwasteInk(8), ePopc(9), ePdeveloper(10), ePfuserOil(11), ePsolidWax(12), ePribbonWax(13), ePwasteWax(14)  

prtmarkersuppliesdescription 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.6
The description of this supply container/receptacle in the localization specified by prtGeneralCurrentLocalization.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

prtmarkersuppliessupplyunit 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.7
Unit of this marker supply container/receptacle.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePtenThousandthsOfInches(3), ePmicrometers(4), ePthousandthsOfOunces(12), ePtenthsOfGrams(13), ePhundrethsOfFluidOunces(14), ePtenthsOfMilliliters(15)  

prtmarkersuppliesmaxcapacity 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.8
The maximum capacity of this supply container/receptacle expressed in SupplyUnit. If this supply container/receptacle can reliably sense this value, the value is sensed by the printer and is read-only; otherwise, the value may be written. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. Additional information: LaserJet 6P cannot sense toner level.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmarkersupplieslevel 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.9
The current level if this supply is a container; the remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is sensed by the printer and is read-only; otherwise, the value may be written. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. A value of (-3) means that the printer knows that there is some supply/remaining space, respectively. Additional information: LaserJet 6P cannot sense toner level, so unknown is always returned.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmediapathdefaultindex 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.9
The value of prtMediaPathIndex corresponding to the default media path; that is, the selection of the default media path. Additional information: The only valid value for this object is 1 (simplex).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

prtmediapathmaxspeedprintunit 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.2
The unit of measure used in specifying the speed of all media paths in the printer.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePtenThousandthsOfInchesPerHour(3), ePmicrometersPerHour(4), ePcharactersPerHour(5), ePlinesPerHour(6), ePimpressionsPerHour(7), ePsheetsPerHour(8), ePdotRowPerHour(9), ePfeetPerHour(16), ePmetersPerHour(17)  

prtmediapathmediasizeunit 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.3
The units of measure of media size for use in calculating and relaying dimensional values for all media paths in the printer.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePtenThousandthsOfInches(3), ePmicrometers(4)  

prtmediapathmaxspeed 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.4
The maximum printing speed of this media path expressed in prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'. Additional information: The page size for this performance is 8.5x11.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmediapathmaxmediafeeddir 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.5
The maximum physical media size in the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-1) implies 'unlimited'. A value of (-2) implies 'unknown' Additional information: The value returned by this object depends on the value of prtMediaPathMediaSizeUnit. It is 140000 if prtInputDimUnit is ePtenThousandthsOfInches or 355600 if prtInputDimUnit is ePmicrometers.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmediapathmaxmediaxfeeddir 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.6
The maximum physical media size across the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies 'unknown'. Additional information: The value returned by this object depends on the value of prtMediaPathMediaSizeUnit. It is 85000 if prtInputDimUnit is ePtenThousandthsOfInches or 216000 if prtInputDimUnit is ePmicrometers.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmediapathminmediafeeddir 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.7
The minimum physical media size in the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies 'unknown'. Additional information: The value returned by this object depends on the value of prtMediaPathMediaSizeUnit. It is 50000 if prtInputDimUnit is ePtenThousandthsOfInches or 127000 if prtInputDimUnit is ePmicrometers.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmediapathminmediaxfeeddir 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.8
The minimum physical media size across the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies 'unknown'. Additional information: The value returned by this object depends on the value of prtMediaPathMediaSizeUnit. It is 30000 if prtInputDimUnit is ePtenThousandthsOfInches or 76200 if prtInputDimUnit is ePmicrometers. This size corresponds to a Monarch envelope.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtmediapathtype 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.9
The type of the media path for this media path.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePsimplex(5)  

prtmediapathdescription 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.10
The manufacturer-provided description of this media path in the localization specified by prtGeneralCurrentLocalization.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

prtmediapathstatus 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.11
The current status of this media path. The status is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transitioning. These values are: Availability value Available and Idle 0 000'b Available and Standby 2 010'b Available and Active 4 100'b Available and Busy 6 110'b Unavailable and OnRequest 1 001'b Unavailable because Broken 3 011'b Unknown 5 101'b Non-Critical No Non-Critical Alerts 0 Non-Critical Alerts 8 Critical No Critical Alerts 0 Critical Alerts 16 On-Line Intended state is On-Line 0 Intended state is Off-Line 32 Transitioning At intended state 0 Transitioning to intended state 64 Additional information: The default values assume the printer is idle.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtchanneltype 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.2
The type of this print data channel. This object provides the linkage to ChannelType-specific groups that may (conceptually) extend the prtChannelTable with additional details about that channel. Additional information: BASE-based channels provide their own values.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePchSerialPort(3), ePchIEEE1284Port(5), ePchAppleTalkPAP(7), ePchNetwarePServer(10), ePchPort9100(11), ePchDLCLLCPort(15), ePchIrDA(35)  

prtchannelprotocolversion 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.3
The version of the protocol used on this channel. The format used for version numbering depends on prtChannelType. Additional information: BASE-based channels provide their own values. The channel 1 value includes (separated by semi colons) different aspects of the spec: electrical: logical; and physical connector.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

prtchannelcurrentjobcntllangindex 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.4
The value of prtInterpreterIndex corresponding to the Control Language Interpreter for this channel. This interpreter defines the syntax used for control functions, such as querying or changing environment variables and identifying job boundaries (e.g. PJL, PostScript, NPAP). Must be 1 or greater. Additional information: This object points to the PJL language. It is read-only because PJL is the printer's only job control language.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtchanneldefaultpagedesclangindex 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.5
The value of prtInterpreterIndex corresponding to the Page Description Language Interpreter for this channel. This interpreter defines the default Page Description Language interpreter to be used for the print data unless the Control Language is used to select a specific interpreter (e.g., PCL, PostScript Language, auto-sense). Must be 1 or greater. Additional information: The default points to the automatic language switcher. If this object is changed for one channel, all channels will be changed.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

prtchannelstate 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.6
The state of this print data channel. The value determines whether control information and print data is allowed through this channel or not. Additional information: BASE-based channels provide their own values for this object. The base-printer's ports always report a value of ePprintDataAccepted. If the printer is offline, that is detected by reading the Host Resources General Printer Status objects, not by reading this object.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePprintDataAccepted(3), ePnoDataAccepted(4)  

prtchannelifindex 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.7
The value of ifIndex (in the ifTable; see the interface section of MIB-2/RFC 1213) which corresponds to this channel. When more than one row of the ifTable is relevant, this is the index of the row representing the topmost layer in the interface hierarchy. A value of zero indicates that no interface is associated with this channel. Additional information: BASE-based channels provide their own values for this object.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtchannelstatus 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.8
The current status of the channel. The status is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transitioning. These values are: Availability value Available and Idle 0 000'b Available and Standby 2 010'b Available and Active 4 100'b Available and Busy 6 110'b Unavailable and OnRequest 1 001'b Unavailable because Broken 3 011'b Unknown 5 101'b Non-Critical No Non-Critical Alerts 0 Non-Critical Alerts 8 Critical No Critical Alerts 0 Critical Alerts 16 On-Line Intended state is On-Line 0 Intended state is Off-Line 32 Transitioning At intended state 0 Transitioning to intended state 64 Additional information: BASE-based channels provide their own values for this object.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtinterpreterlangfamily 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.2
The family name of a Page Description Language (PDL) or control language which this interpreter in the printer can interpret or emulate. This type 2 list of enumerations requires review before additional entries are made.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePlangPCL(3), ePlangPJL(5), ePlangPS(6), ePlangAutomatic(37), ePlangPCLXL(47)  

prtinterpreterlanglevel 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.3
The level of the language which this interpreter is interpreting or emulating. This might contain a value like '5e' for an interpreter which is emulating level 5e of the PCL language. It might contain '2' for an interpreter which is emulating level 2 of the PostScript language. Similarly it might contain '2' for an interpreter which is emulating level 2 of the HPGL language.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..31)  

prtinterpreterlangversion 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.4
The date code or version of the language which this interpreter is interpreting or emulating. Additional information: For PostScript, this is more detailed revision info.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..31)  

prtinterpreterdescription 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.5
A string to identify this interpreter in the localization specified by prtGeneralCurrentLocalization as opposed to the language which is being interpreted. It is anticipated that this string will allow manufacturers to unambiguously identify their interpreters. Additional information: None of these strings are localized.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

prtinterpreterversion 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.6
The date code, version number, or other product specific information tied to this interpreter. This value is associated with the interpreter, rather than with the version of the language which is being interpreted or emulated. Additional information: Same as prtInterpreterLangVersion.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..31)  

prtinterpreterdefaultorientation 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.7
The current orientation default for this interpreter. This value may be overridden for a particular job (e.g., by a command in the input data stream). Additional information: Interpreters 1 and 2 ignore the value of this object. The values for PCL and PostScript are either ePportrait or ePlandscape; attempting to set them to a different value will cause to be returned. Setting this object for one interpreter will change it for all installed interpreters.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER ePportrait(3), ePlandscape(4)  

prtinterpreterfeedaddressability 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.8
The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnit s (see prtMarkerAddressabilityFeedDir ) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtinterpreterxfeedaddressability 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.9
The maximum interpreter addressability in the cross feed direction in 10000 prtMarkerAddressabilityUnit s (see prtMarkerAddressabilityXFeedDir) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtinterpreterdefaultcharsetin 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.10
The default coded character set for input octets encountered outside a context in which the Page Description Language established the interpretation of the octets. This value shall be (2) if there is no default. Additional information: ePcsAdobeStandardEncoding is the same as PSText(10J). The object corresponding to PCL has read-write acces; all others are read-only. the above list corresponds to the following symbol sets as they appear on the Control Panel: ePother( 1) - used if designated coded char. set not in list ePcsASCII( 3) - ISO-6 ePcsISOLatin1( 4) - ISO L1 ePcsISOLatin2( 5) - IS L2 ePcsISOLatinArabic(9) - WINBALT ePcsISOLatin5( 12) - ISO L5 ePcsISOLatin6( 13) - ISO L6 ePcsISO4UnitedKingdom( 20) - ISO-4 ePcsISO11SwedishforNames( 21) - ISO-11 ePcsISO15Italian( 22) - ISO-15 ePcsISO17Spanish( 23) - ISO-17 ePcsISO21German( 24) - ISO-21 ePcsISO60DanishNorwegian( 25) - ISO-60 ePcsISO69French( 26) - ISO-69 ePcsUnicodeIBM2039(1004) - PC-1004 ePcsWindows30Latin1( 2000) - WIN 3.0 ePcsWindows31Latin1( 2001) - WIN L1 ePcsWindows31Latin2( 2002) - WIN L2 ePcsWindows31Latin5( 2003) - WIN L5 ePcsHPRoman8( 2004) - ROMAN-8 ePcsAdobeStandardEncoding( 2005) - PS TEXT ePcsPC850Multilingual( 2009) - PC-850 ePcsPCp852( 2010) - PC-852 ePcsPC8CodePage437( 2011) - PC-8 ePcsPC8DNDanishNorwegian( 2012) - PC-8DN ePcsHPPC8Turkish( 2014) - PC-8 TK ePcsHPLegal( 2017) - LEGAL ePcsHPDeskTop( 2021) - DESKTOP ePcsMacintosh(2027) - MC TEXT
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER ePother(1), ePcsASCII(3), ePcsISOLatin1(4), ePcsISOLatin2(5), ePcsISOLatinArabic(9), ePcsISOLatin5(12), ePcsISOLatin6(13), ePcsISO4UnitedKingdom(20), ePcsISO11SwedishforNames(21), ePcsISO15Italian(22), ePcsISO17Spanish(23), ePcsISO21German(24), ePcsISO60DanishNorwegian(25), ePcsISO69French(26), ePcsUnicodeIBM2039(1004), ePcsWindows30Latin1(2000), ePcsWindows31Latin1(2001), ePcsWindows31Latin2(2002), ePcsWindows31Latin5(2003), ePcsHPRoman8(2004), ePcsAdobeStandardEncoding(2005), ePcsPC850Multilingual(2009), ePcsPCp852(2010), ePcsPC8CodePage437(2011), ePcsPC8DNDanishNorwegian(2012), ePcsHPPC8Turkish(2014), ePcsHPLegal(2017), ePcsHPDeskTop(2021), ePcsMacintosh(2027)  

prtinterpreterdefaultcharsetout 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.11
The default character set for data coming from this interpreter through the printer's output channel. This value shall be (2) if there is no default.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePcsNoDefault(2), ePcsASCII(3), ePcsHPRoman8(2004), ePcsAdobeStandardEncoding(2005)  

prtinterpretertwoway 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.12
Indicates whether or not this interpreter returns information back to the host.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePyes(3), ePno(4)  

prtconsolelocalization 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.10
The value of the prtLocalizationIndex corresponding to the language, country, and character set to be used for the console. This localization applies both to the actual display on the console as well as the encoding of these console objects in management operations. Additional information: The value of this object is saved in NVRAM. If a localized string is currently being displayed on the control panel by the device, changing this object will cause the displayed string to be changed to its new value. If this object is changed while the printer is processing a page that contains localized strings, the results are undefined.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 1..13  

prtconsolenumberofdisplaylines 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.11
The number of lines on the printer's physical display. This value is 0 if there are no lines on the physical display or if there is no physical display Additional information: LaserJet 6P has no physical display, however this object can be used to determine the size of the remote control panel display size for prtConsoleDisplayBufferText.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

prtconsolenumberofdisplaychars 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.12
The number of characters per line displayed on the physical display. This value is 0 if there are no lines on the physical display or if there is no physical display Additional information: LaserJet 6P has no physical display, however this object can be used to determine the size of the remote control panel display size for prtConsoleDisplayBufferText.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

prtconsoledisable 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.13
This object enables or disables manual input from the operators console. Additional information: LaserJet 6P has no display.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePenabled(3), ePdisabled(4)  

prtconsoledisplaybuffertext 1.3.6.1.4.1.11.2.3.9.4.2.2.16.5.1.2
The content of a line in the logical display buffer of the operator's console of the printer. When a write operation occurs, normally a critical message, to one of the LineText strings, the agent should make that line displayable if a physical display is present. Writing a zero length string clears the line. It is an implementation-specific matter as to whether the agent allows a line to be overwritten before it has been cleared. Printer generated strings shall be in the localization specified by ConsoleLocalization. Management Application generated strings should be localized by the Management Application.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

prtconsoleontime 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.2
The on time in milliseconds of blinking of this light; 0 indicates off always. If both prtConsoleOnTime and prtConsoleOffTime are 0, then the light is always off. Additional information: LaserJet 6P does not have any LEDs.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtconsoleofftime 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.3
The off time in milliseconds of blinking of this light; 0 indicates on always. If both prtConsoleOnTime and prtConsoleOffTime are 0, then the light is always off. Additional information: LaserJet 6P does not have any LEDs.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtconsolecolor 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.4
The color of this light. Additional information: LaserJet 6P does not have any LEDs.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePunknown(2), ePwhite(3), ePred(4), ePgreen(5), ePblue(6), ePcyan(7), ePmagenta(8), ePyellow(9)  

prtconsoledescription 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.5
The vendor description or label of this light in the localization specified by prtConsoleLocalization. Additional information: LaserJet 6P does not have any LEDs.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

prtalertseveritylevel 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.2
The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePcritical(3), ePwarning(4)  

prtalerttraininglevel 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.3
The level of training required to handle this alert. The training level is an enumeration that is determined and assigned by the printer manufacturer based on the information or the training required to handle this alert. The printer will break alerts into these different training levels. It is the responsibility of the management application in the system to determine how a particular alert is handled and how and to whom that alert is routed. The following are the four training levels of alerts: Field Service - Alerts that typically require advanced training and technical knowledge of the printer and its sub-units. An example of a technical person would be a manufacture's Field Service representative, or other person formally trained by the manufacturer or similar representative. Trained - Alerts that require an intermediate or moderate level of knowledge of the printer and its sub-units. A typical examples of alerts that a trained operator can handle is replacing toner cartridges. Untrained - Alerts that can be fixed without prior training either because the action to correct the alert is obvious or the printer can help the untrained person fix the problem. A typical example of such an alert is reloading paper trays and emptying output bins on a low end printer. Management - Alerts that have to do with overall operation of and configuration of the printer. Examples of management events are configuration change of sub-units. Additional information: The value of this object depends on the alert condition as follows: ePuntrained: Paper low/out. ePtrained: Toner low. ePfieldService: Marker failure. ePmanagement: Configuration change.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePuntrained(3), ePtrained(4), ePfieldService(5), ePmanagement(6)  

prtalertgroup 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.4
The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Whereever possible, these enumerations match the sub-identifier that identifies the relevant table in the printmib.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePgeneralPrinter(5), ePcover(6), ePinput(8), ePoutput(9), ePmarker(10), ePchannel(14)  

prtalertgroupindex 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.5
An index of the row within the principle table in the group identified by prtAlertGroup that represents the sub-unit of the printer that caused this alert. The combination of the Group and the GroupIndex defines exactly which printer sub-unit caused the alert.; for example, Input #3, Output #2, and Marker #1. Every object in this MIB is indexed with hrDeviceIndex and optionally, another index variable. If this other index variable is present in the table that generated the alert, it will be used as the value for this object. Otherwise, this value shall be -1.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtalertlocation 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.6
The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is used in conjunction with the Group and GroupIndex values; for example, there is an alert in Input #2 at location number 7.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

prtalertcode 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.7
The code that describes the type of alert for this entry in the table. There are different codes for each sub-unit type: for example, Media Supply Low and Media Supply Empty are Aler codes for the Input sub-unit.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER ePother(1), ePjam(8), ePdoorOpenAlert(501), ePinputMediaTrayMissing(801), ePinputMediaSupplyEmpty(808), ePmarkerFuserUnderTemperature(1001), ePmarkerFuserOverTemperature(1002), ePmarkerTonerEmpty(1101), ePmarkerTonerAlmostEmpty(1104)  

prtalertdescription 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.8
A description of this alert entry in the localization specified by prtGeneralCurrentLocalization. The description is provided by the printer to further elaborate on the enumerated alert or provide information in the case where the code is classified ask `other' or `unknown'. The printer is required to return a description string but the string may be a null string.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)