LMS-MIB

File: LMS-MIB.mib (34864 bytes)

Imported modules

RFC-1212 RFC-1213 RFC1155-SMI

Imported symbols

OBJECT-TYPE DisplayString enterprises

Defined Types

MarconiLMSBinaryAlarmEntry  
SEQUENCE    
  binaryAlarmIndex DisplayString Size(0..5)
  binaryAlarmName DisplayString Size(0..30)
  binaryAlarmStatus DisplayString Size(0..8)
  binaryAlarmAlarmStatus DisplayString Size(0..8)
  binaryAlarmClass DisplayString Size(0..5)
  binaryAlarmReportType DisplayString Size(0..10)
  binaryAlarmDuration DisplayString Size(0..8)

MarconiLMSBinaryChannelEntry  
SEQUENCE    
  binaryChannelIndex DisplayString Size(0..5)
  binaryChannelName DisplayString Size(0..30)
  binaryChannelStatus DisplayString Size(0..8)
  binaryChannelAlarmStatus DisplayString Size(0..8)
  binaryChannelAlarmClass DisplayString Size(0..5)

MarconiLMSAnalogAlarmEntry  
SEQUENCE    
  analogAlarmIndex DisplayString Size(0..5)
  analogAlarmName DisplayString Size(0..30)
  analogAlarmValue DisplayString Size(0..8)
  analogAlarmUnits DisplayString Size(0..4)
  analogAlarmLimitValue DisplayString Size(0..8)
  analogAlarmLimitType INTEGER
  analogAlarmLimitName DisplayString Size(0..10)
  analogAlarmLimitClass DisplayString Size(0..5)
  analogAlarmReportType DisplayString Size(0..10)
  analogAlarmDuration DisplayString Size(0..8)

MarconiLMSAnalogChannelEntry  
SEQUENCE    
  analogChannelIndex DisplayString Size(0..5)
  analogChannelName DisplayString Size(0..30)
  analogChannelValue DisplayString Size(0..12)
  analogChannelUnits DisplayString Size(0..4)
  analogChannelLimit1 DisplayString Size(0..8)
  analogChannelLimit2 DisplayString Size(0..8)
  analogChannelLimit3 DisplayString Size(0..8)
  analogChannelLimit4 DisplayString Size(0..8)
  analogChannelAlarm INTEGER

MarconiLMSRelayAlarmEntry  
SEQUENCE    
  relayAlarmIndex DisplayString Size(0..5)
  relayAlarmName DisplayString Size(0..30)
  relayAlarmStatus DisplayString Size(0..8)
  relayAlarmAlarmStatus DisplayString Size(0..8)
  relayAlarmClass DisplayString Size(0..5)
  relayAlarmReportType DisplayString Size(0..10)
  relayAlarmDuration DisplayString Size(0..8)

MarconiLMSRelayChannelEntry  
SEQUENCE    
  relayChannelIndex DisplayString Size(0..5)
  relayChannelName DisplayString Size(0..30)
  relayChannelStatus DisplayString Size(0..8)
  relayChannelAlarmStatus DisplayString Size(0..8)
  relayChannelAlarmClass DisplayString Size(0..5)

MarconiLMSLedAlarmEntry  
SEQUENCE    
  ledAlarmIndex DisplayString Size(0..5)
  ledAlarmName DisplayString Size(0..30)
  ledAlarmStatus DisplayString Size(0..8)
  ledAlarmAlarmStatus DisplayString Size(0..8)
  ledAlarmClass DisplayString Size(0..5)
  ledAlarmReportType DisplayString Size(0..10)
  ledAlarmDuration DisplayString Size(0..8)

MarconiLMSLEDChannelEntry  
SEQUENCE    
  ledChannelIndex DisplayString Size(0..5)
  ledChannelName DisplayString Size(0..30)
  ledChannelStatus DisplayString Size(0..8)
  ledChannelAlarmStatus DisplayString Size(0..8)
  ledChannelAlarmClass DisplayString Size(0..5)

MarconiLMSEnergyChannelEntry  
SEQUENCE    
  energyChannelIndex DisplayString Size(0..5)
  energyChannelName DisplayString Size(0..30)
  energyCapacity DisplayString Size(0..8)
  energyShunt DisplayString Size(0..8)
  energyRFA INTEGER
  energyTR INTEGER

MarconiLMSFunctionChannelEntry  
SEQUENCE    
  functionChannelIndex DisplayString Size(0..5)
  functionChannelName DisplayString Size(0..30)
  functionChannelValue DisplayString Size(0..8)
  functionChannelUnits DisplayString Size(0..4)
  functionChannelLimit1 DisplayString Size(0..8)
  functionChannelLimit2 DisplayString Size(0..8)
  functionChannelLimit3 DisplayString Size(0..8)
  functionChannelLimit4 DisplayString Size(0..8)
  functionChannelAlarm INTEGER

MarconiLMSFunctionAlarmEntry  
SEQUENCE    
  functionAlarmIndex DisplayString Size(0..5)
  functionAlarmName DisplayString Size(0..30)
  functionAlarmValue DisplayString Size(0..8)
  functionAlarmUnits DisplayString Size(0..5)
  functionAlarmLimitValue DisplayString Size(0..16)
  functionAlarmLimitType INTEGER
  functionAlarmLimitName DisplayString Size(0..12)
  functionAlarmLimitClass DisplayString Size(0..5)
  functionAlarmReportType DisplayString Size(0..10)
  functionAlarmDuration DisplayString Size(0..8)

Defined Values

emersonESNA 1.3.6.1.4.1.885
OBJECT IDENTIFIER    

lms 1.3.6.1.4.1.885.2
OBJECT IDENTIFIER    

lmsSystem 1.3.6.1.4.1.885.2.1
OBJECT IDENTIFIER    

lmsCounts 1.3.6.1.4.1.885.2.2
OBJECT IDENTIFIER    

lmsChannels 1.3.6.1.4.1.885.2.3
OBJECT IDENTIFIER    

lmsTraps 1.3.6.1.4.1.885.2.5
OBJECT IDENTIFIER    

binaryChannelNumber 1.3.6.1.4.1.885.2.2.1
The number of Binary channels in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

analogChannelNumber 1.3.6.1.4.1.885.2.2.2
The number of Analog channels in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

relayChannelNumber 1.3.6.1.4.1.885.2.2.3
The number of Relay channels in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ledChannelNumber 1.3.6.1.4.1.885.2.2.4
The number of LED channels in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

energyChannelNumber 1.3.6.1.4.1.885.2.2.5
The number of Energy Management channels in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

functionChannelNumber 1.3.6.1.4.1.885.2.2.6
The number of Function channels in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmsBinaryAlarmTable 1.3.6.1.4.1.885.2.5.11
The table entry for a Binary Alarm
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSBinaryAlarmEntry

lmsBinaryAlarmEntry 1.3.6.1.4.1.885.2.5.11.1
An entry containing the information returned by a Binary Trap
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSBinaryAlarmEntry  

binaryAlarmIndex 1.3.6.1.4.1.885.2.5.11.1.1
The Binary channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

binaryAlarmName 1.3.6.1.4.1.885.2.5.11.1.2
The Binary channel name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..30)  

binaryAlarmStatus 1.3.6.1.4.1.885.2.5.11.1.3
The Binary channel state (CC=voltage applied)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

binaryAlarmAlarmStatus 1.3.6.1.4.1.885.2.5.11.1.4
The Binary channel alarm status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

binaryAlarmClass 1.3.6.1.4.1.885.2.5.11.1.5
The Binary channel alarm class
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

binaryAlarmReportType 1.3.6.1.4.1.885.2.5.11.1.6
The Binary channel alarm condition
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

binaryAlarmDuration 1.3.6.1.4.1.885.2.5.11.1.7
The length of time the Binary alarm has been active
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

lmsBinaryChannelTable 1.3.6.1.4.1.885.2.3.1
The table listing for the Binary channel information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSBinaryChannelEntry

lmsBinaryChannelEntry 1.3.6.1.4.1.885.2.3.1.1
An entry containing information about a individual Binary channel.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSBinaryChannelEntry  

binaryChannelIndex 1.3.6.1.4.1.885.2.3.1.1.1
The Binary channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

binaryChannelName 1.3.6.1.4.1.885.2.3.1.1.2
The Binary channel name
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

binaryChannelStatus 1.3.6.1.4.1.885.2.3.1.1.3
The Binary channel state (CC=voltage applied)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

binaryChannelAlarmStatus 1.3.6.1.4.1.885.2.3.1.1.4
The Binary channel alarm status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

binaryChannelAlarmClass 1.3.6.1.4.1.885.2.3.1.1.5
The Binary channel alarm class
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

lmsAnalogAlarmTable 1.3.6.1.4.1.885.2.5.10
The table entry for an Analog channel Alarm
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSAnalogAlarmEntry

lmsAnalogAlarmEntry 1.3.6.1.4.1.885.2.5.10.1
An entry containing the information returned by an Analog channel Trap
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSAnalogAlarmEntry  

analogAlarmIndex 1.3.6.1.4.1.885.2.5.10.1.1
The Analog channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

analogAlarmName 1.3.6.1.4.1.885.2.5.10.1.2
The Analog channel name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..30)  

analogAlarmValue 1.3.6.1.4.1.885.2.5.10.1.3
The Analog channel reading
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

analogAlarmUnits 1.3.6.1.4.1.885.2.5.10.1.4
The Analog channel reading units of measurement
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..4)  

analogAlarmLimitValue 1.3.6.1.4.1.885.2.5.10.1.5
The Analog channel limit value
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

analogAlarmLimitType 1.3.6.1.4.1.885.2.5.10.1.6
The Analog channel limit type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

analogAlarmLimitName 1.3.6.1.4.1.885.2.5.10.1.7
The Analog channel limit name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

analogAlarmLimitClass 1.3.6.1.4.1.885.2.5.10.1.8
The Analog channel limit condition
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

analogAlarmReportType 1.3.6.1.4.1.885.2.5.10.1.9
The Analog channel limit condition
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

analogAlarmDuration 1.3.6.1.4.1.885.2.5.10.1.10
The length of time the Analog limit has been active
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

lmsAnalogChannelTable 1.3.6.1.4.1.885.2.3.2
The table listing for the Analog channel information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSAnalogChannelEntry

lmsAnalogChannelEntry 1.3.6.1.4.1.885.2.3.2.1
An entry containing information about an individual Analog channel.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSAnalogChannelEntry  

analogChannelIndex 1.3.6.1.4.1.885.2.3.2.1.1
The Analog channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

analogChannelName 1.3.6.1.4.1.885.2.3.2.1.2
The Analog channel name
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

analogChannelValue 1.3.6.1.4.1.885.2.3.2.1.3
The Analog channel reading
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..12)  

analogChannelUnits 1.3.6.1.4.1.885.2.3.2.1.4
The Analog channel reading units of measurement
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..4)  

analogChannelLimit1 1.3.6.1.4.1.885.2.3.2.1.5
The Analog channel limit number one value
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

analogChannelLimit2 1.3.6.1.4.1.885.2.3.2.1.6
The Analog channel limit number two value
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

analogChannelLimit3 1.3.6.1.4.1.885.2.3.2.1.7
The Analog channel limit number three value
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

analogChannelLimit4 1.3.6.1.4.1.885.2.3.2.1.8
The Analog channel limit number four value
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

analogChannelAlarm 1.3.6.1.4.1.885.2.3.2.1.9
The Analog channel alarm status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmsRelayAlarmTable 1.3.6.1.4.1.885.2.5.13
The table entry for a Relay Alarm
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSRelayAlarmEntry

lmsRelayAlarmEntry 1.3.6.1.4.1.885.2.5.13.1
An entry containing the information returned by a Relay Trap
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSRelayAlarmEntry  

relayAlarmIndex 1.3.6.1.4.1.885.2.5.13.1.1
The Relay channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

relayAlarmName 1.3.6.1.4.1.885.2.5.13.1.2
The Relay channel name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..30)  

relayAlarmStatus 1.3.6.1.4.1.885.2.5.13.1.3
The Relay channel status (On, Forced, Programmed)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

relayAlarmAlarmStatus 1.3.6.1.4.1.885.2.5.13.1.4
The Relay channel alarm status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

relayAlarmClass 1.3.6.1.4.1.885.2.5.13.1.5
The Relay channel alarm class
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

relayAlarmReportType 1.3.6.1.4.1.885.2.5.13.1.6
The Relay channel alarm condition
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

relayAlarmDuration 1.3.6.1.4.1.885.2.5.13.1.7
The length of time the Relay alarm has been active
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

lmsRelayChannelTable 1.3.6.1.4.1.885.2.3.3
The table listing for the Relay channel information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSRelayChannelEntry

lmsRelayChannelEntry 1.3.6.1.4.1.885.2.3.3.1
An entry containing information about an individual Relay channel.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSRelayChannelEntry  

relayChannelIndex 1.3.6.1.4.1.885.2.3.3.1.1
The Relay channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

relayChannelName 1.3.6.1.4.1.885.2.3.3.1.2
The Relay channel name
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

relayChannelStatus 1.3.6.1.4.1.885.2.3.3.1.3
The Relay channel status (On, Forced, Programmed)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

relayChannelAlarmStatus 1.3.6.1.4.1.885.2.3.3.1.4
The Relay channel alarm status
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

relayChannelAlarmClass 1.3.6.1.4.1.885.2.3.3.1.5
The Relay channel alarm class
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..5)  

lmsLedAlarmTable 1.3.6.1.4.1.885.2.5.1
The table entry for a Led Alarm
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSLedAlarmEntry

lmsLedAlarmEntry 1.3.6.1.4.1.885.2.5.1.1
An entry containing the information returned by a LED Trap
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSLedAlarmEntry  

ledAlarmIndex 1.3.6.1.4.1.885.2.5.1.1.1
The LED channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

ledAlarmName 1.3.6.1.4.1.885.2.5.1.1.2
The LED channel name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..30)  

ledAlarmStatus 1.3.6.1.4.1.885.2.5.1.1.3
The LED channel status (On, Forced, Programmed)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

ledAlarmAlarmStatus 1.3.6.1.4.1.885.2.5.1.1.4
The LED channel alarm status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

ledAlarmClass 1.3.6.1.4.1.885.2.5.1.1.5
The LED channel alarm class
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

ledAlarmReportType 1.3.6.1.4.1.885.2.5.1.1.6
The LED channel alarm condition
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

ledAlarmDuration 1.3.6.1.4.1.885.2.5.1.1.7
The length of time the LED alarm has been active
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

lmsLEDChannelTable 1.3.6.1.4.1.885.2.3.4
The table listing for the LED channel information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSLEDChannelEntry

lmsLEDChannelEntry 1.3.6.1.4.1.885.2.3.4.1
An entry containing information about an individual LED channel.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSLEDChannelEntry  

ledChannelIndex 1.3.6.1.4.1.885.2.3.4.1.1
The LED channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

ledChannelName 1.3.6.1.4.1.885.2.3.4.1.2
The LED channel name
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

ledChannelStatus 1.3.6.1.4.1.885.2.3.4.1.3
The LED channel status (On, Forced, Programmed)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

ledChannelAlarmStatus 1.3.6.1.4.1.885.2.3.4.1.4
The LED channel alarm status
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

ledChannelAlarmClass 1.3.6.1.4.1.885.2.3.4.1.5
The LED channel alarm class
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..5)  

lmsEnergyChannelTable 1.3.6.1.4.1.885.2.3.5
The table listing for the Energy Management channel information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSEnergyChannelEntry

lmsEnergyChannelEntry 1.3.6.1.4.1.885.2.3.5.1
An entry containing information about an individual Energy Management channel.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSEnergyChannelEntry  

energyChannelIndex 1.3.6.1.4.1.885.2.3.5.1.1
The Energy Management channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

energyChannelName 1.3.6.1.4.1.885.2.3.5.1.2
The Energy Management channel name
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

energyCapacity 1.3.6.1.4.1.885.2.3.5.1.3
The rated capacity of the rectifier associated with the Energy Management channel
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

energyShunt 1.3.6.1.4.1.885.2.3.5.1.4
The current load on the rectifier associated with the Energy Management channel
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

energyRFA 1.3.6.1.4.1.885.2.3.5.1.5
The current operational status of the rectifier associated with the Energy Management channel
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

energyTR 1.3.6.1.4.1.885.2.3.5.1.6
The current control status of the rectifier associated with the Energy Management channel
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmsFunctionChannelTable 1.3.6.1.4.1.885.2.3.6
The table entry for a Function channel Alarm
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSFunctionChannelEntry

lmsFunctionChannelEntry 1.3.6.1.4.1.885.2.3.6.1
An entry containing the information returned by a Function channel Trap
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSFunctionChannelEntry  

functionChannelIndex 1.3.6.1.4.1.885.2.3.6.1.1
The Function channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

functionChannelName 1.3.6.1.4.1.885.2.3.6.1.2
The Function channel name
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

functionChannelValue 1.3.6.1.4.1.885.2.3.6.1.3
The Function channel reading
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

functionChannelUnits 1.3.6.1.4.1.885.2.3.6.1.4
The Function channel reading units of measurement
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..4)  

functionChannelLimit1 1.3.6.1.4.1.885.2.3.6.1.5
The Function channel limit number one value
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

functionChannelLimit2 1.3.6.1.4.1.885.2.3.6.1.6
The Function channel limit number two value
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

functionChannelLimit3 1.3.6.1.4.1.885.2.3.6.1.7
The Function channel limit number three value
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

functionChannelLimit4 1.3.6.1.4.1.885.2.3.6.1.8
The Function channel limit number four value
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

functionChannelAlarm 1.3.6.1.4.1.885.2.3.6.1.9
The Function channel alarm status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmsFunctionAlarmTable 1.3.6.1.4.1.885.2.5.12
The table entry for a Function channel Alarm
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarconiLMSFunctionAlarmEntry

lmsFunctionAlarmEntry 1.3.6.1.4.1.885.2.5.12.1
An entry containing the information returned by a Function channel Trap
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MarconiLMSFunctionAlarmEntry  

functionAlarmIndex 1.3.6.1.4.1.885.2.5.12.1.1
The Function channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

functionAlarmName 1.3.6.1.4.1.885.2.5.12.1.2
The Function channel name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..30)  

functionAlarmValue 1.3.6.1.4.1.885.2.5.12.1.3
The Function channel reading
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

functionAlarmUnits 1.3.6.1.4.1.885.2.5.12.1.4
The Function channel reading units of measurement
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

functionAlarmLimitValue 1.3.6.1.4.1.885.2.5.12.1.5
The Function channel limit value
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

functionAlarmLimitType 1.3.6.1.4.1.885.2.5.12.1.6
The Function channel limit value
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

functionAlarmLimitName 1.3.6.1.4.1.885.2.5.12.1.7
The Function channel limit name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..12)  

functionAlarmLimitClass 1.3.6.1.4.1.885.2.5.12.1.8
The Function channel alarm class
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

functionAlarmReportType 1.3.6.1.4.1.885.2.5.12.1.9
The Function channel limit condition
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

functionAlarmDuration 1.3.6.1.4.1.885.2.5.12.1.10
The length of time the Function limit has been active
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)